1 INTERNAL VIBRATOR-FREQUENCY INVERTER IRFUN.../ en Operator s Manual

2

3 FOREWORD Foreword For your own safety and protection from bodily injuries, carefully read, understand and follow the safety instructions in this manual. Please operate and maintain your Wacker machine in accordance with the instructions in this manual. Your Wacker machine will reward your attention by giving trouble-free operation and a high degree of availability. Defective machine parts are to be replaced as soon as possible. All rights, especially the right for copying and distribution are reserved Copyright by Wacker Construction Equipment AG No part of this publication may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express permission in writing from Wacker Construction Equipment AG. Any type of reproduction, distribution or saving on data carriers of any type or method not authorized by Wacker represents an infringement of valid copyrights and will be prosecuted. We expressly reserve the right to technical modifications- even without express due notice - which aim at improving our machines or their safety standards. T00778GB 1

4 TABLE OF CONTENTS FOREWORD 1 SAFETY INSTRUCTIONS 3 General instructions 3 Operation 3 Safety checks 4 Maintenance 4 Transport 4 Maintenance checks 4 TECHNICAL DATA 5 DESCRIPTION 7 Field of application 7 Description of function 7 OPERATION 8 Starting operating 8 Switching the unit off 8 DESCRIPTION/MAINTENANCE 9 Connection 9 Thermal protection 9 Maintenance schedule 9 Disassembly and assembly 10 Maintenance 10 REPAIR INSTRUCTIONS 11 Repair instructions, failures 11 WEAR MEASUREMENTS 14 DIAGRAM 15 EC - CONFORMITY-CERTIFICATE GBIVZ.GB.doc 2

5 SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS FOR INTERNAL VIBRATORS (POKERS) WITH BUILT-IN FREQUENCY CONVERTERS General instructions 1. IRFUN internal vibrators may only be operated by persons who: * are at least 18 years of age * are physically and mentally fit for this job * have been instructed in operating IRFUN's and proven their ability for the job to the employer * may be expected to carry out the job they are charged with carefully The persons must be assigned for the job of operating the IRFUN by the employer. 2. The IRFUN may only be run as directed for the compaction of concrete, while taking into account the manufacturer s Operating Instructions and under observation of these Safety Instructions. The equipment must be immersed in the mass to be compacted. 3. The persons entrusted with the operation of IRFUN are to be familiarized with the necessary safety precautions relating to the machine. In the case of unusual applications the contractor must compile and issue the necessary additonal instructions. 4. The accident prevention regulations of the employer s liability insurance association for electrical plant and equipment are to be observed and used as a basis for all work with this machine. Operation 1. It must be ensured that electrically driven IRFUNs are only connected to the voltage and frequency specified on the nameplate. The nameplate is located on the inside of the switch housing cover. Moreover, the voltage to which the machine is to be connected is engraved on the switch housing. Choose correct cross section for extension cord. See calculation example and diagram included in this manual. 2. The IRFUN may only be connected to an electric power supply fitted out with a ground fault interrupteur (GFI). Either an universal-sensitive differential current protective breaker must be used or make sure that the IRFUN is the only equipment - no additional equipment allowed -connected to a GFI protective circuit breaker designed for use with loads with non-sinusoidal (distorted) current consumption. Only use power supply sockets with 15 A fuses when connecting IRFUNs to the public mains net. 3. The equipment corresponds to the protection class 1 (grounded/earthed conductor). 4. Ensure that the different components are tightly screwed together before starting the equipment. 5. The IRFUN must not to be switched on and off by inserting the plug into the socket or pulling it out. 6. The power supply cable of the IRFUN must not be used to pull the plug out of the socket. 7. Protect electric cables against heat, oil and sharp edges. 8. Electrical plant and epuipment may only be used if they satisfy the operational and local safety requirements. They must be in perfect working order and must to be kept in this condition. 9. Avoid touching solid objects over longer periods of time when operating the IRFUNs. Also avoid running them without load, i.e. in the air. 10. During work breaks or when the IRFUN is left on its own, the machine is to be switched off and positioned so that it is impossible for it to inadvertently roll away or fall. 11. It is forbidden to operate IRFUN's in potentially explosive environments. 12. Handling the IRFUN is allowed only with suitable protective gloves. Do not touch the vibrator casing tube as it may be hot. SV00033GB 3

6 SAFETY INSTRUCTIONS 13. Only hold the equipment by its protective hose during operation. Do not hold the IRFUN by its vibrator housing tube, as this could lead to vascular disorders. 14. The transmission of the vibration oscillations into the material to be compacted could lead to a bursting of the shuttering or formwork. Secure the shuttering or formwork as prescribed before compacting concrete with the equipment. Safety checks 1. The effectiviness of the operating, and safety devices must be checked before work is commenced. 2. Check cables and electric plug receptacle to be sure they are not damaged before connecting equipment. 3. Additionally carry out an operational test of the ON/OFF switch and the ground fault interrupter (GFI). 4. The supervisor must be notifed without delay. If defects in the safety devices or other defects are detected which impair the safe operation of the machine. 5. Operations must be discontinued immediately in the event of defects which jeopardise operational safety. 6. Check the vibrator s lower housing tube to be sure that it is not cracked nor damaged and that the screwed connection is not loose. A lost lower tube leads will render the vibrator unserviceable. 7. Check the hose clamps at the connections. ATTENTION! Depending on the switch position the equipment could immediately start running when connected to the current supply. This could also happen in the case of a damaged switch. Maintenance The opening and repairing of the IRFUN may only be carried out by trained and authorized personnel. 1. Only use original spare parts. Modifications to this machine including the adjustment of the maximum engine speed set by the manufacturer are subject to the express approval of Wacker. In case of nonobservance all liabilities shall be refused. 2. The IRFUN must be disconnected from the current supply when carrying out maintenance and repair jobs - pull out the plug from the electric receptacle. 3. Work on electrical components of this machine may only be performed by a specialist. 4. The green/yellow protective earth conductor of the connection cable must be longer so that it does not become detached if the strain relief clamp fails. There is a danger to life and limb if this connection is broken. After repair work, check protective earth conductor for continuity. 5. Protective devices must be correctly mounted back again after maintenance or repair jobs. Screwed connections must be tightened with torques such as indicated in the standards. 6. Clean the IRFUN daily. Do not damage the cables when cleaning with high water pressure equipment. Transport Secure the IRFUN against dropping down during transport. Maintenance checks Depending on the mode of operation and the site conditions, the operational safety of IRFUN's is to be checked as and when required, but at least once every 6 months by a specialist, e.g. at a Wacker customer service station, and if necessary, repaired. In addition, please observe the relevant regulations and guidelines applicable in your country. SV00033GB 4

7 TECHNICAL DATA IRFUN 38 IRFUN 45 Item no / / Internal vibrator Built in 3-phase motor Voltage Frequency Ratend current Vibrations Dia. vibrator head Length vibrator head Weight (mass), vibrator (without hose connection) Compaction rate in concrete Oil Converter input ratings Alternating current Frequency Ratend current Power input kw: V: Hz: A: min -1 : mm: mm: kg: up to cm: cm 3 : V: Hz: A. kva: 0,47 0, ~ 200 1,6 2, ,2 3, ~ 50 / ,69 0,92 IRFUN 38 The required sound specifications, called-for by the EC-Machine Regulations per Appendix 1, Paragraph f, are - the sound level, measured at 1m distance, L pa = 79 db(a) This noise level was determined according to ISO 6081 for the sound pressure level (L pa ). The weighted effective value of acceleration, determined according to ISO 8662, Part 1, is under 2,5 m/s 2. This noise and vibration data was determined while the internal vibrator was suspended freely, with the motor running at nominal speed. TD00499GB 5

8 TECHNICAL DATA IRFUN 57 IRFUN 57k Item no / / Internal vibrator Built in 3-phase motor Voltage Frequency Ratend current Vibrations Dia. vibrator head Length vibrator head Weight (mass), vibrator (without hose connection) Compaction rate in concrete Oil Converter input ratings Alternating current Frequency Ratend current Power input kw: V: Hz: A: min -1 : mm: mm: kg: up to cm: cm 3 : V: Hz: A. kva: 1,04 0, ~ 200 3,5 2, ,6 4, ~ 50 / ,38 1,15 IRFUN 45 / 57 The required sound specifications, called-for by the EC-Machine Regulations per Appendix 1, Paragraph f, are - the sound level, measured at 1m distance, L pa = 79 db(a) This noise level was determined according to ISO 6081 for the sound pressure level (L pa ). The weighted effective acceleration value, determined according to ISO 8662, Part 1, is 4 m/s 2. This noise and vibration data was determined while the internal vibrator was suspended freely, with the motor running at nominal speed. TD00499GB 6

9 DESCRIPTION Field of application The machine is run with single phase current, and is a combination of an internal vibrator and a frequency converter. Description of function The power converter assembly of the transformer carries out a rectification of the input voltage. In the inverted rectifier the direct voltage is converted into three-phase alternating current, at the same time increasing the frequency from 50/60 Hz to 200 Hz. The inverted rectifier operates in "pulse-width modulation" which causes a sinusoidal output to be produced as average value which in turn allows fault-proof operation of the units connected. Due to the smooth starting of the units connected, the supply capacity of the transformer can be used completely. The power converter and the inverted rectifier are triggered by means of a control electronics unit with a microprocessor. 50/60 Hz 200 Hz Power converter 100/115/230/240 V Inverted rectifier Electronics Pulse-width modulation sinusoidal average value T00216GB 7

10 OPERATION Starting operating Connection: The IRFUN will be factory-set to its nominal voltage. Connect to single phase A.C. 50 or 60 Hz. Operation: When switching the IRFUN on, both the tension and the frequency will be driven up synchronically until reaching their nominal values (soft start). Critical starting currents are thus avoided. ATTENTION! IRFUN's may be connected to a power generator only if the operating voltage of the generator lies within 230/115 V + 15% under any load conditions, the IRFUN alone is connected to the generator and if the manufacturer of the power unit provides for equipment with capacitors to be connected. If the IRFUN is to be driven by a geneator, use only a synchronous generator if possible. Switching the unit off First switch off the IRFUN. Thereafter remove mains plug from the socket. ATTENTION! The IRFUN may be opened only after the plug has been removed from the socket for two minutes as the capacitors mounted have to discharge first of all. Perform work only under off-voltage conditions. T00694GB 8

11 DESCRIPTION/MAINTENANCE Connection The internal vibrators are to be connected to a 200 cycle Wacker 3-phase frequency and voltage converter with correct output voltage (see list). Thermal protection Additional full motor protection by way of 1 thermal switch per phase! This vibrator has been equipped with a thermal circuit breaker for protection against possible overheating. Disconnect the vibrator and let it cool off if the thermal circuit breaker responds. Maintenance schedule Components Maintenance jobs Maintenance interval Supply line Visual check of cable and switch housing diaphragm. daily Vibrator Oil change. 200 hours T00606GB 9

12 DESCRIPTION/MAINTENANCE Disassembly and assembly ATTENTION! Only clamp the Internal vibrator in the lower region of the thick-walled nose cap. a Vibrator housing sizes a k k 105 Maintenance Change SAE 10W oil after approx. 200 working hours. For oil quantity see table. Remove welding point and lower housing for oil change. Clean away used oil from the inside of the exciter housing. Apply pipe threaded seal ergo 4205 to the threads and then screw on the lower part of the housing (torque setting of, see spare parts list). Change the corresponding parts once their wear measurement has been reached. To secure both housing parts apply a welding point at the connection seam. Connection between hose connection point and vibrator housing: Make sure to correctly connect the flat connectors (1) and secure them by way of the heat-shrinkable sleeve (2). See sketch below. T00606GB 10

13 REPAIR INSTRUCTIONS Repair instructions, failures The luminous diodes ease the search for defects in case of equipment failures. The equipment must be opened to be able to observe the diodes. ATTENTION! The printed circuit board is under current, even after disconnecting the equipment from the mains, as long as the green luminous diode is on. Only after the condensers have discharged, will the green diode turn off. When the IRFUN recognizes a defect it will disconnect automatically. In this case a red diode will light up when the equipment is connected. Possible failures: Cable interruption between inverter and vibrator head Insulation defect at inverter, motor cable or vibrator head Inverter overload Inverter output overload due to short circuit, earth leakage or defect in vibrator head High / low mains input voltage Operation signal lamp The output frequency of 200 Hz out by means of the potentiometer. Fix the adjusting screw of the potentiometer with a drop of paint. T00695GB 11

14 T00695GB 12

15 REPAIR INSTRUCTIONS When in the presence of problems, five red LED s and one green LED incorporated within the inverter make a diagnosis easier. To get to the diagnosis lamps it certainly is necessary to open the inverter housing and then also to apply electrical current (make alive). This job may only be carried out by technically trained personnel or staff correspondingly instructed. ATTENTION! There is a chance of bodily harm if one of the capacitors should explode and if the potting compound is hurtled outward when applying electrical current to the inverter. It is for this reason that safety glasses should be worn on principle and that the area above the capacitors should be kept away from. Under all circumstances carry out a visual inspection of the open inverter before applying an electrical current. Capacitors with a domed (cambered) cover or a projecting higher end have already been previously damaged. Do not apply electrical current under any circumstances to such an inverter. Malfunction Cause Remedy Green LED does not light up. Internal vibrator (IR) not functioning. Green and first red LED light up. IR not functioning. Green and second red LED light up. IR not functioning. Green and third red LED light up. IR not functioning. Green and fourth red LED light up. IR not functioning. Green and fifth red LED light up. IR not functioning. - Supply cable interruption. - Bad contacts. - Broken cable between inverter (FU) and IR. - Defect in the FU electronics. - Short to ground inside the FU or IR. - Temperature inside FU housing to high. - IR runs with difficulty (sluggishly). - Short circuit between FU and IR. - Wrong input voltage, too high or too low. - Check supply line. - Check contacts (switch, plugs) and rework if necessary. - Check electrical wiring and replace if necessary. - Replace FU. - Run insulation test at IR and FU, replace defective parts. - Measure amperages (*) on the output side. - Correct fault in IT. - Find point of short circuit by measuring and then eliminate. - Measure voltage at switch. - Check generator. (*) - see technical data A metal oxide varistor has been included in the input circuit as an additional safety for the equipment against input voltages which are too high. The varistor looks quite similar to a small plate capacitor. Its characteristics are similar to those of a Zener diode (DIN) and it has high current-carrying capacity. Its resistance of more than 1 MW breaks down under extreme circumstances to less than 1 W in less than 50 nanoseconds when overloaded. In this way the electronics of the IRFU are protected against an input voltage that is too high. T00695GB 13

16 WEAR MEASUREMENTS Type Dimension / limits for vibrator heads and nose caps øl L L L ø L L mm mm mm mm IREN (38) 338 (345) 36 (38) 218 IREN (45) 372 (382) 42 (45) 333 IREN (58) 390 (400) 54,0 (58) 253 IREN 57k 50 (58) 320 (330) 54,0 (58) 213 IREN 65 52(65) 475(490) 58 (65) 322 IREN 65k 52(65) 385(400) 58 (65) 258 Length L and L L to be measured from casing end (Initial measurements) 1 Bold printed figures are condemnation limits. 2 Figures in brackets are original dimensions of new equipment. 3 Replace heads latest when condemnation limits ø (over length L) are reached. 4 Replace end caps latest when condemnation limits L L and øl L are reached. SK00439GB 14

17 DIAGRAM Selection of required cross section for extension of cables and power lines This procedure takes into consideration: 1. The ohmic and inductive resistance of the line with an admissible loss of voltage of 5% and cos phi = 0,8 as per voltage-frequency-curves. 2. The admissible warming-up of the lines as per VDE standard. Voltage - Frequency - Curves Cross-section area of cable in mm 2 Rated current x length of cable A x m Model: Rated current: Power supply cable: Input cable cross-section: IRFUN 38 3 A 66 m 110 m 176 m 262 m IRFUN 45 4 A 50 m 83 m 132 m 196 m IRFUN 57 6 A 33 m 55 m 88 m 130 m IRFUN 57k 5A 40 m 66 m 105 m 157 m 1,5 mm 2 2,5 mm 2 4 mm 2 6 mm 2 1,5 mm 2 2,5 mm 2 4 mm 2 6 mm 2 1,5 mm 2 2,5 mm 2 4 mm 2 6 mm 2 1,5 mm 2 2,5 mm 2 4 mm 2 6 mm 2 ATTENTION! Use 2.5 sq. mm cable if in doubt about exact extension length. SK00493GB 15

18 16

19 EC - CONFORMITY-CERTIFICATE Wacker Construction Equipment AG, Preußenstraße 41, München hereby certify that the construction equipment specified hereunder: 1. Category: 2. Type: Internal vibrators with inverters IRFUN 38/230 IRFUN 45/230 IRFUN 57/230 (k) 3. Equipment item number: has been produced in accordance with the following standards: * 98/37/EWG * 89/336/EWG... Dr. Sick Board of Directors File certificate carefully C GB

20 18

21

22

23

24

en Internal vibrators IRSEN-FU Operator's manual

en Internal vibrators IRSEN-FU Operator's manual www.wackergroup.com 0203059en 003 02.2007 Internal vibrators IRSEN-FU Operator's manual 1. Foreword Foreword For your own safety and protection from bodily injuries, carefully read, understand and follow

More information

en Converter FU 4/5 Operator s Manual

en Converter FU 4/5 Operator s Manual www.wackergroup.com 0201424en 003 02.2007 Converter FU 4/5 Operator s Manual 1. Foreword Foreword For your own safety and protection from bodily injuries, carefully read, understand and follow the safety

More information

VIBRATORY PLATE DPU 2440F WGB en Operator s Manual

VIBRATORY PLATE DPU 2440F WGB en Operator s Manual www.wackergroup.com VIBRATORY PLATE DPU 2440F WGB 0201436en - 10.2002 0007877 101 Operator s Manual CONTENTS Type Item no. DPU 2440F WGB 0007877... H00396GB 1 2 FOREWORD Foreword For your own safety and

More information

DPU 2950 DPU 2960 DPU 2970

DPU 2950 DPU 2960 DPU 2970 www.wackergroup.com VIBRATORY PLATE DPU 2950 DPU 2960 DPU 2970 0200165en - 10.2002 0007881 100 0007883 100 0007880 100 Operator s Manual CONTENTS Type Item no. DPU 2950 0007881... DPU 2960 0007883...

More information

VIBRATORY PLATE DPU 2440H DPU 2450H en Operator s Manual

VIBRATORY PLATE DPU 2440H DPU 2450H en Operator s Manual www.wackergroup.com VIBRATORY PLATE DPU 2440H DPU 2450H 0200320en - 10.2002 0007870 102 0008746 101 Operator s Manual CONTENTS Type Item no. DPU 2440H 0007870... DPU 2450H 0008746... This machine has

More information

en Electrik-breaker EHB 11 BLM/... Operator s Manual

en Electrik-breaker EHB 11 BLM/... Operator s Manual 0203037en 002 06.2006 Electrik-breaker EHB 11 BLM/... Operator s Manual 1. Foreword Foreword For your own safety and protection from bodily injuries, carefully read, understand and follow the safety instructions

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

en Vibratory plate DPU Operator s Manual

en Vibratory plate DPU Operator s Manual www.wackergroup.com 0203512en 001 01.2006 Vibratory plate DPU 100-70 Operator s Manual CONTENTS Type Item no. DPU 100-70 0008900... This machine has been equipped with an EPA certified engine. Additional

More information

en Electrik-breaker EH 27/115 Douple insulated WMM WC Operator s Manual

en Electrik-breaker EH 27/115 Douple insulated WMM WC Operator s Manual www.wackergroup.com 0203032en 001 06.2006 Electrik-breaker EH 27/115 Douple insulated WMM WC Operator s Manual SAFETY INSTRUCTIONS WARNING! When using electric tools, basic safety precautions should always

More information

PURE SINE WAVE DC TO AC POWER INVERTER

PURE SINE WAVE DC TO AC POWER INVERTER PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read

More information

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN Operating instructions Rotary actuators M135 M140 M150 M180 June 2012 / 118614 / EN General information General information Proof of amendment Copyright Subject to alterations Manufacturer Version Date

More information

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7 Please read these Installation and Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunction or to clutch failure, resulting in damage to other

More information

Mass Sine 24/10000 Mass Sine 24/15000

Mass Sine 24/10000 Mass Sine 24/15000 USERS- AND INSTALLATION MANUAL Mass Sine 24/10000 Mass Sine 24/15000 Modular high power inverter system MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands ENGLISH: PAGE 1 Tel.: +31-20-342

More information

en Vibratory plate DPU 25..H.. Operator s Manual

en Vibratory plate DPU 25..H.. Operator s Manual www.wackergroup.com 0109976en 001 01.2005 Vibratory plate DPU 25..H.. Operator s Manual 1. Foreword Foreword For your own safety and protection from bodily injuries, carefully read, understand and follow

More information

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB Operating Instructions Bedienungsanleitung Mode d emploi DW 400 EWB 400 575 EWB 400 575 800 www.bron-kobold.com Operating instructions EWB 400.575 EWB 400.575.800 Before use Please read all the information

More information

en Vibratory plate DPU 4045H Operator s Manual

en Vibratory plate DPU 4045H Operator s Manual www.wackergroup.com 0203089en 001 11.2004 Vibratory plate DPU 4045H Operator s Manual CONTENTS Type Item no. DPU 4045H 0007888... DPU 4045H - 750 wide 0007935... This machine has been equipped with an

More information

Instruction Manual. Sewage lifting station compli 300

Instruction Manual. Sewage lifting station compli 300 Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

Technical Manual Electrical Power Supply System T4002

Technical Manual Electrical Power Supply System T4002 Technical Manual Electrical Power Supply System T400 MOZELT GmbH & Co. KG Please observe the following safety information and recommendations before start-up! Copyright: MOZELT GmbH & Co. KG, D-4769 Duisburg

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

Electrical operating instructions

Electrical operating instructions en Electrical operating instructions Reversing contactor universal 2 Contactor / 24V for three- and single- phase motor 51171134 - d 04.2009 OPERATING INSTRUCTIONS 52210115 consisting of: E : Electrical

More information

PL Submersible, Semi-Vortex, Water Feature Pump

PL Submersible, Semi-Vortex, Water Feature Pump TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and

More information

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES ADDITIONAL EMERGENCY POWER SUPPLY DEVICES ADDITIONAL EMERGENCY POWER SUPPLY DEVICES OP Emergency power supplies according to VDE 0107 ZSV installations according to VDE 0107 AREAS OF USE Hospitals Out-patient

More information

Matala. VersiFlow Series. Instruction and Maintenance Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and

More information

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA 5.52.714.00.1.0 Edition 03.2004 GB Operating and Maintenance Manual for HADEF overhead crane as jointed crane TA Subject to changes. 1 HADEF Table of Contents 1 General Page 3 2 Product description Page

More information

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C C Mobile Communications 13 AMPERE POWER SUPPLY 19A704647P1-P3 CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER

More information

Mechanical Operating Instructions

Mechanical Operating Instructions Mechanical Operating Instructions SE 5.24 WS / SE 5.24 51172095 / 04.2006 Bau muster Zertifizierung geprüft EN 13241-1 OPERATING INSTRUCTIONS 52210111 consisting of: M : Mechanical Operating Instructions

More information

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9 Please read the Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to clutch failure, resulting in damage to other parts. Contents:

More information

Hydraulic Breakers HH35. Prior to Operation. From Serial No Revised We thank you for choosing a HYCON breaker.

Hydraulic Breakers HH35. Prior to Operation. From Serial No Revised We thank you for choosing a HYCON breaker. Hydraulic Breakers HH35 From Serial No. 12263 Revised 01.02.2015 Prior to Operation We thank you for choosing a HYCON breaker. To ensure smooth operation and long-lasting performance of your new breaker,

More information

HST-BL-2830MS & HST-BL-2830MS-USA

HST-BL-2830MS & HST-BL-2830MS-USA HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com

More information

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z INSTRUCTION MANUAL I/P Converter DSG BXXY3Z DSG BXXY4Z Revision 2.0 3.626 016136 en Page 1/15 Should you have any questions concerning the I/P converter, please contact the Service Department of the Product

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8 Contents : 1. INTRODUCTION...1 2. IMPORTANT SAFETY INSTRUCTIONS...2 3. SYSTEM DESCRIPTION...4 3.1 Front Panel...4 4. CONNECTION AND OPERATION...6 5. TROUBLESHOOTING...8 6. MAINTENANCE...9 6.1 Operation...9

More information

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories. Be sure to thoroughly read and understand the SAFETY PRES given in this section before using the equipment in order to operate the equipment correctly. The precautionary measures described in this section

More information

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company Manufacturer of Dimensions Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL April

More information

Appendix: Safety and application notes for... 15

Appendix: Safety and application notes for... 15 Contents Safety... 2 Warnings... 2 Symbols used in this manual... 2 Operator s safety... 2 Avoid filter module damage... 2 DC-link resonance... 2 Description... 3 Description... 3 Ordering numbers, 380-415

More information

LINE CONDITIONERS USER'S GUIDE

LINE CONDITIONERS USER'S GUIDE LINE CONDITIONERS USER'S GUIDE PE 1411/10 (9415 014 11 101) PE 1412/10 (9415 014 12 101) PE 1413/10 (9415 014 13 101) PE 1411/15 (9415 014 11 151) PE 1412/15 (9415 014 12 151) PE 1413/15 (9415 014 13 151)

More information

.3 Section Waste Management and Disposal.

.3 Section Waste Management and Disposal. Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

GeyserMax-Flow Series

GeyserMax-Flow Series GeyserMax-Flow Series 115V/60Hz Waterfall Pump GM-3900 1/5HP 150W / Discharge 1-1/2 GM-4700 1/3HP 250W / Discharge 2 GM-5400 1/2HP 400W / Discharge 2 GM-6200 3/4HP 750W / Discharge 2 230V/50Hz GM-3800

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

Operating manual Separator

Operating manual Separator Operating manual Separator Sheet no. AS/4.1.141.1.1 issue 20.08.2014 Contents Section Title Page 0 Introduction... 1 1 Intended use......1 2 Marking of the fitting... 1 3 Safety instructions... 2 4 Transport

More information

ARC 1850 LIST OF FIGURES

ARC 1850 LIST OF FIGURES PAGE 1.0 INTRODUCTION... 1 2.0 WARRANTY... 1 3.0 UNPACKING YOUR UNIT... 1 4.0 SUGGESTED SAFETY PRECAUTIONS...... 1 4.1 PERSONAL SAFETY PRECAUTIONS. 1 4.2 POWER SUPPLY SAFETY PRECAUTIONS.. 2 5.0 GENERAL

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP INDRA HYDR TECH PUMPS PVT. LTD. 16, 1st Floor, th Cross, 4th Phase, Peenya Industrial Area, Bengaluru

More information

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software APC's Back-UPS ES series is now "greener" than ever. The ES 350 utilizes an ultra-efficient design that consumes less power

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

Operating Instructions

Operating Instructions Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3

More information

ABB Switzerland Ltd Phone Surge arresters Telefax:

ABB Switzerland Ltd Phone Surge arresters Telefax: Operating Manual Publication number 1HC0023892 Low Voltage Limiter Type HVL 120-0.3 With metal oxide varistor and thyristors from ABB Silicon housing material for indoor and outdoor applications Transport,

More information

Instruction Manual. Low Profile Lift Table

Instruction Manual. Low Profile Lift Table Instruction Manual Low Profile Lift Table Note: Owner/Operator must read and understand this instruction manual before using the low profile lift table. THANK YOU VERY MUCH FOR SELECTING OUR PRODUCT. THIS

More information

IP 900 W/KS & IP 900 D/KS

IP 900 W/KS & IP 900 D/KS B W/KS & D/KS Installation and operating instructions We reserve the right to make modifications in the interest of technical development (4) 15975178 GB 04/05 1 pplication reas The submersible waste-water

More information

8.50 Kampmann Equestrian Solarium Perfect Enhances the Vital Functions and the Immune System Table of Contents.

8.50 Kampmann Equestrian Solarium Perfect Enhances the Vital Functions and the Immune System Table of Contents. 1.26 1.45 8.50 Kampmann Equestrian Solarium Perfect Table of Contents Table of Contents 1.26 1.46 1. Correct and Proper Use.......................................... 3 1.1 Personal Qualification 1.2 Limits

More information

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation

More information

MIL-24/2600Q MIL-24/3200DQ

MIL-24/2600Q MIL-24/3200DQ Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121473B OWNER'S

More information

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601) Instruction and Operation Manual valid for art.-no.: 10091 F-TA-05/C-ISO (start at modification No. 1601) valid for art.-no.: 10092 F-TA-05/C-Sh (start at modification No. 1601) CAUTION: As with any form

More information

PRODUCT MANUAL TILE CUTTING MACHINE. . Operation. Parts List and Diagram SPECIFICATIONS CAUTION:

PRODUCT MANUAL TILE CUTTING MACHINE. . Operation. Parts List and Diagram SPECIFICATIONS CAUTION: FLORCRAFTT TM PRODUCT MANUAL SKU NUMBER 709-4242 SERIAL NUMBER: CAUTION: FOR YOUR OWN SAFETY READ INSTRUCTION MANUAL COMPLETELY AND CAREFULLY BEFORE OPERATING THIS 7 TILECUTTING MACHINE SPECIFICATIONS

More information

Operating Instructions Pedestrian Turnstile Type MPT 33

Operating Instructions Pedestrian Turnstile Type MPT 33 Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11

More information

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH PrioVino Premier Translation of Original Operating Instructions Status: August 2018 First edition January 2018 / PrioVino GmbH Reprint even in extracts only upon written permission by PrioVino GmbH (ISO

More information

Battery Charger. Series EASY Charger. User s manual

Battery Charger. Series EASY Charger. User s manual Battery Charger Series EASY Charger User s manual 1 Warranty RIPEnergy is not manufacturer of these units. All technical information s, data s and dimensions rely on information s given by the manufacturer.

More information

Operating Instructions Overcurrent Protection - Tester

Operating Instructions Overcurrent Protection - Tester Operating Instructions Overcurrent Protection - Tester WWW.LECOM.CN CONTENTS Table of contents 1. ORDER REFERENCE...2 1.1. Standard set...2 1.2. Options...3 2. INTRODUCTION...4 2.1. General description...4

More information

RF Point Level Control with Sensor Monitor

RF Point Level Control with Sensor Monitor The 681 Point Level Control utilizes DPDT relays to provide switching for peripheral devices (such as pumps) in level applications. A sensor attached to the control acts as an antenna to transmit the process

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP Declaration of Conformity Company Name Indra Hydro Tech Pumps Pvt. Ltd. Address 16, 4th Phase, th Cross,

More information

User manual Pipe notcher Type: AL 1-2E

User manual Pipe notcher Type: AL 1-2E User manual Pipe notcher Type: AL 1-2E Page 1 of 27 Table of contents 1. Foreword... 4 1.1. Name of machine... 4 1.2. Warning... 4 1.3. Target group for each chapter... 4 1.4. Symbols... 4 1.5. Re-ordering

More information

ADI-125/750 ADI-125/1500 ADI-125/2500

ADI-125/750 ADI-125/1500 ADI-125/2500 Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121094B OWNERS

More information

1/2 HP SUMP PUMP OWNER'S MANUAL

1/2 HP SUMP PUMP OWNER'S MANUAL TM 1/2 HP SUMP PUMP OWNER'S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps EI-700-008 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to Operation

More information

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com MODEL : BANTAM C8 BANTAM C10 PART NO. : 602-325A 602-343A SERIAL NO. : PLEASE READ THIS OPERATION AND MAINTENANCE MANUAL CAREFULLY BEFORE USING YOUR NEW CUTLASS STUD WELDER. COPYRIGHT CFI 2009 email: sales@

More information

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA Installation and operating instructions Solar charge controller 10 A / 15 A / 0 A / 30 A EN 74.86 08.4 1. About this manual These operating

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL JANUARY

More information

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com MODEL : BANTAM C8 PART NO. : 602-325P SERIAL NO. : PLEASE READ THIS OPERATION AND MAINTENANCE MANUAL CAREFULLY BEFORE USING YOUR NEW CUTLASS STUD WELDER. COPYRIGHT CFI 2009 email: sales@ PAGE - 1 - WARRANTY

More information

VIBRATORY PLATE BPU 2950A en Operator s Manual

VIBRATORY PLATE BPU 2950A en Operator s Manual www.wackergroup.com VIBRATORY PLATE BPU 2950A 0200201en - 10.2002 0007962 100 Operator s Manual CONTENTS Type Item no. BPU 2950A 0007962... This machine has been equipped with an EPA certified engine.

More information

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition July 2007 Contents Contents Page 1 Design and

More information

Disc Grinder Model G 18MR G 23MR G 23MRU

Disc Grinder Model G 18MR G 23MR G 23MRU Disc Grinder Model G 18MR G 23MR G 23MRU Handling instructions G23MR NOTE: Before using this Electric Power Tool, carefully read through these HANDLING INSTRUCTIONS to ensure efficient, safe operation.

More information

HD18F2M1.

HD18F2M1. HD18F2M1 www.blackanddecker.com 3 2 1 5 A 4 5 B 4 7 10 9 C 4 6 D 4 8 1 11 12 E 2 F 3 2 G H 13 I 14 13 14 K 3 J 3 L M 16 15 4 Intended use Your Black & Decker hand held vacuum cleaner has been designed

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible

More information

Operation and Maintenance Manual Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 http://www.torsionx.com Use the MaxDrv Series Square Drive Torque Wrench Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 to install and remove threaded

More information

MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL

MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL 1 TABLE OF CONTENTS 1.0 SPECIFICATIONS 2.0 GENERAL OPERATING INSTRUCTIONS 3.0 BASIC OPERATING PARTS 4.0 BASIC

More information

PAGE 1 OF 5 HEALTH, SAFETY & ENVIRONMENTAL MANUAL PROCEDURE: S360 Overhead Cranes & Lifts Procedure REV 4.0 8/14/2012

PAGE 1 OF 5 HEALTH, SAFETY & ENVIRONMENTAL MANUAL PROCEDURE: S360 Overhead Cranes & Lifts Procedure REV 4.0 8/14/2012 PAGE 1 OF 5 PURPOSE: OVERHEAD CRANES AND LIFTS PROCEDURE The purpose of this procedure is to define the safety and training requirements for use of overhead cranes and lifts. Procedure: Definitions Designated

More information

KEWTECH. KT56 digital multi function tester. Instruction manual

KEWTECH. KT56 digital multi function tester. Instruction manual KEWTECH KT56 digital multi function tester Instruction manual Contents 1 Safety Notice 1 2 Features and Principles of Measurement 3 3 Introduction 6 4 Specifications 7 5 Instrument layout 9 6 Operating

More information

6L Oil-less Air Compressor 53103

6L Oil-less Air Compressor 53103 6L Oil-less Air Compressor 53103 Operating Instructions Please read and save these instructions before attempting to assemble, install, operate or maintain the product. Protect yourself and others by observing

More information

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013. 172-65177M-02 (TATSU2) 7 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Air Trap TATSU2 Copyright 2013 by TLV CO., LTD. All rights reserved 1 Contents

More information

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 120015D OWNERS

More information

Adjustable Speaker Mount GRAVIS 12

Adjustable Speaker Mount GRAVIS 12 Adjustable Speaker Mount GRAVIS 12 User's Manual Translation of the original instructions Version 3.3 Released: 19.01.2017 Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße

More information

HPD Hydraulic Post Driver

HPD Hydraulic Post Driver HPD Hydraulic Post Driver From serial No. 7600 Revised 04.01.2013 Prior to Operation We thank you for choosing a HYCON Post Driver. To ensure smooth operation and long-lasting performance of your new post

More information

WaltZilla TM Installation and Operation Guide

WaltZilla TM Installation and Operation Guide The Boldest, Baddest Charging Station on the Planet! WaltZilla TM Installation and Operation Guide Software Version 2.0.1 or higher UL File # E473741 LiquidSky Technologies, Inc. 716 Beacon Street Newton

More information

BODAS Pressure sensor PR3 series 10

BODAS Pressure sensor PR3 series 10 BODAS Pressure sensor PR3 series 10 RE 95155 Edition: 04.2014 Replaces: 12.2013 Measurement ranges to 25, 50, 160, 200, 250, 400, 600 bar Ratiometric output signal 0.5 to 4.5 V with 5 V supply voltage

More information

BRAVER UPS. (Uninterruptible Power System) User s Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

Adjustable Speaker Mount GRAVIS 8

Adjustable Speaker Mount GRAVIS 8 Adjustable Speaker Mount GRAVIS 8 User's Manual Translation of the original instructions Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße 14 D-30179 Hannover TEL +49 (0)

More information

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11 Please read and observe this Operating Instruction carefully! A possible malfunction or failure of the brake and any damage may be caused by not observing it. Table of contents: Page 1: Page 2: Page 3:

More information

GD series Submersible Grinder Pump

GD series Submersible Grinder Pump GD series Submersible Grinder Pump 60HZ STAIRS INDUSTRIAL CO., LTD. GD series-submersible Grinder Pump Model code GD - 15-30 - M A A = AUTO M = Single Phase T = Three Phase Connection dimensions Output

More information

IBT Series Square Drive Torque Wrenches

IBT Series Square Drive Torque Wrenches IBT Series Square Drive Torque Wrenches Operation and Maintenance Manual Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 http://www.torsionx.com Use the IBT Series Square Drive Torque Wrenches Model.75, 1, 3,

More information

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

XPS-ProFeed Shuttle SERVICE MANUAL. Revised: XPS-ProFeed Shuttle SERVICE MANUAL Revised: 1-14-15 RENA SYSTEMS INC. 910 East Main Street; Suite 200 Norristown, PA 19401-4110 Phone: (610) 650-9170 Fax: (610) 270-3947 Web Site: www.renausa.com SAFETY

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL WREN IBT SERIES HYDRAULIC TORQUE WRENCHES IBT SQUARE DRIVE SERIES OPERATION AND MAINTENANCE MANUAL FOR WREN Products: POINT 75, 1IBT, 3IBT, 5IBT, 8IBT, 10IBT, 20IBT, 25IBT, 35IBT, 50IBT SQUARE DRIVE HYDRAULIC

More information

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4 Braking Resistor Units 3G3IV-PCDBR2 B/4 B Braking Units Thank you for choosing an OMRON Braking Resistor Unit and Braking Unit. Proper use and handling

More information

Product Information Overspeed governor GB 260

Product Information Overspeed governor GB 260 Product Information GB 260 Copyright as per DIN ISO 16016. Manufactured under licence of C. Haushahn GmbH & Co. I Subject to modification. Published by SLC Sautter Lift Components GmbH & Co. KG Borsigstrasse

More information

Electric Vehicle Charging Station

Electric Vehicle Charging Station EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;

More information

Powerful & Intelligent Submersible Pumps

Powerful & Intelligent Submersible Pumps TM Powerful & Intelligent Submersible Pumps NW2256 (mfr. AC 22365) 1/3 HP Motor Capacity is 1250 gallons per hour Adjustable Automatic or Manual Operating Switch Assorted adapter fittings including garden

More information

en Vibratory plate BPU 3050A Operator s Manual

en Vibratory plate BPU 3050A Operator s Manual www.wackergroup.com 0203080en 001 01.2005 Vibratory plate BPU 3050A Operator s Manual CONTENTS Type Item no. BPU 3050A 0008763... This machine has been equipped with an EPA certified engine. Additional

More information

Mounting and Operating Manual Non-Return valves Swing-Check valves

Mounting and Operating Manual Non-Return valves Swing-Check valves Mounting and Operating Manual Non-Return valves Swing-Check valves END-Armaturen GmbH & Co. KG Oberbecksener Str. 78 D-32547 Bad Oeynhausen Telefon (05731) 7900-0 Telefax (05731) 7900-199 http://www.end.de

More information