Installation, Operation and Maintenance Manual

Size: px
Start display at page:

Download "Installation, Operation and Maintenance Manual"

Transcription

1 TM Solar Charging System Controller Installation, Operation and Maintenance Manual For the most recent manual revisions, see the version at: MAXIMUM POWER POINT TRACKING... Solar Battery Charging... Load Control... Diversion Control MODELS TS-45 TS-60 TS-60M

2 Table of Contents Important Safety Instructions TriStar Description Versions and Ratings Operating Modes Adjustability General Use Safety and Regulatory Information Optional Accessories...11 This page inside front COVER 2 (Please do not print this copy) 2.0 Installation General Information Installation Overview Installation Steps Remove the Cover Mounting Adjust Switches Remote Temperature Sensor Battery Voltage Sense System Wiring and Power-up RS-232 Adjustments Finish Installation Operation Operator s Tasks Push-button LED Indications Protections and Fault Recovery Data-Logging Inspection and Maintenance Solar Battery Charging PWM Battery Charging Four Stages of Solar Charging Battery Charging Notes Standard Battery Charging Programs Temperature Effects & Battery Voltage Sense Remote Temperature Sensor (RTS) Battery Voltage Sense Equalization Standard Equalization Programs Typical qualizations Preparation for equalization When to Equalize Equalize a Sealed Battery? Float...41 (continued) i MORNINGSTAR CORPORATI

3 5.0 Load & Lighting Control General Load & Lighting Control Notes Inductive Loads Parallel TriStars Reverse Polarity Load Control Settings LVD Warning Diversion Charge Control Diversion Charge Control Diversion Current Ratings Standard Diversion Battery Charging Programs Battery Charging References Selecting the Diversion Load Suitable Loads for Diversion Defintion of Terms Load Power Ratings Maximum Diversion Load Minimum Diversion Load NEC Requirements Second Independent Means Percent Rating Additional Information Custom Settings with PC Software Connection to a Computer Using the PC Software Changing Set-points Finish Self-Test / Diagnostics General Troublshooting Troubleshooting Solar Charging Troubleshooting Load Control Troubleshooting Diversion Control Battery Information (reference) Sealed Batteries Flooded Batteries L-16 Cells Warranty Specifications Appendix 1 - Load and Lighting Control Switch Settings...61 Appendix 2 - Diversion Charge Control SwitchSettings...66 Appendix 3 - LED Indications Certifications IMPORTANT SAFETY INSTRUCTIS SAVE THESE INSTRUCTIS. This manual contains important safety, installation, operating and mantenance instructions for the TriStar-PWM solar controller. The following symbols are used throughout this manual to indicate potentially dangerous conditions or mark important safety instructions: WARNING: Indicates a potentially dangerous condition. Use extreme caution when performing this task. CAUTI: Indicates a critical procedure for safe and proper operation of the controller. NOTE: Indicates a procedure or function that is important to the safe and proper operation of the controller. CSIGNES IMPORTANTES DE SÉCURITÉ CSERVEZ CES INSTRUCTIS. Ce manuel contient des instructions importantes de sécurité, d installations et d utilisation du contrôleur solaire. TriStar-PWM. Les symboles suivants sont utilisés dans ce manuel pour indiquer des conditions potentiellement dangereuses ou des consignes importantes de sécurité. AVERTISSEMENT: Indique une condition potentiellement dangereuse. Faites preuve d une prudence extrême lors de la réalisation de cette tâche. PRUDENCE: Indique une procédure critique pour l utilisation sûre et correcte du contrôleur. REMARQUE: Indique une procédure ou fonction importante pour l utilisation sûre et correcte du contrôleur. Safety Information Read all of the instructions and cautions in the manual before beginning installation. There are no user serviceable parts inside the TriStar-PWM. Do not disassemble or attempt to repair the controller. ii TABLE OF CTENTS continued... 1 MORNINGSTAR CORPORATI

4 WARNING: RISK OF ELECTRICAL SHOCK. NO POWER OR ACCESSORY TERMINALS ARE ELECTRICALLY ISOLATED FROM DC INPUT, AND MAY BE ENERGIZED WITH HAZARD- OUS SOLAR VOLTAGE. UNDER CERTAIN FAULT CDITIS, BATTERY COULD BECOME OVER-CHARGED. TEST BETWEEN ALL TERMINALS AND GROUND BEFORE TOUCHING. External solar and battery disconnects are required. Disconnect all sources of power to the controller before installing or adjusting the TriStar-PWM. There are no fuses or disconnects inside the TriStar-PWM Do not attempt to repair. The battery bank must be comprised of batteries of same type, make, and... age. IEC certified for use in negative ground or floating systems only Do not smoke near the battery bank. Power connections must remain tight to avoid excessive heating from a loose connection. Use properly sized conductors and circuit interrupters. The grounding terminal is located in the wiring compartment and is identified by the symbol below: Informations de Sécurité Lisez toutes les instructions et les avertissements figurant dans le manuel avant de commencer l installation. Le TriStar-PWM ne contient aucune pièce réparable par l utilisateur. Ne démontez pas ni ne tentez de réparer le contrôleur. AVERTISSEMENT: RISQUE DE CHOC ÉLECTRIQUE. N ALIMENTATI OU AUX BORNES D ACCESSOIRES ST ISOLÉS ÉLECTRIQUEMENT DE L ENTRÉE DE C.C ET DOIT ÊTRE ALIMENTÉS À UNE TENSI DANGEREUSE SOLAIRE. SOUS CERTAINES CDITIS DE DÉFAILLANCE, LA BATTERIE POURRAIT DEVENIR TROP CHARGÉE. TEST ENTRE TOUTES LES BORNES ET LA MASSE AVANT DE TOUCHER. External solaire et la batterie se déconnecte sont nécessaires. Déconnectez toutes les sources d alimentation du contrôleur avant d installer ou de régler le TriStar-PWM. Le TriStar MPPT ne contient aucun fusible ou interrupteur. Ne tentez pas de réparer. Installez des fusibles/coupe-circuits externes selon le besoin. Installation Safety Precautions WARNING: This unit is not provided with a GFDI device. This charge controller must be used with an external GFDI device as required by the Article 690 of the National Electrical Code for the installation location. Mount the TriStar-PWM indoors. Prevent exposure to the elements and do not allow water to enter the controller. Install the TriStar-PWM in a location that prevents casual contact. The TriStar- PWM heatsink can become very hot during operation. Use insulated tools when working with batteries. Avoid wearing jewelry during installation. Ground Symbol This charge controller is to be connected to DC circuits only. These DC connections are identified by the symbol below: Direct Current Symbol The TriStar-PWM controller must be installed by a qualified technician in accordance with the electrical regulations of the country where the product is installed. A means of disconnecting all power supply poles must be provided. These disconnects must be incorporated in the fixed wiring. A permanent, reliable earth ground must be established with connection to the TriStar-PWM wiring compartment ground terminal. The grounding conductor must be secured against any accidental detachment. The knock-outs in the TriStar-PWM wiring compartment must protect wires with conduit or rubber rings. Précautions de Sécurité D installation AVERTISSEMENT: L appareil n est pas fourni avec un dispositif GFDI. Ce contrôleur de charge doit être utilisé avec un dispositif GFDI externe tel que requis par l Article 690 du Code électrique national de l emplacement de l installation. Montez le TriStar-PWM à l intérieur. Empêchez l exposition aux éléments et la pénétration d eau dans le contrôleur. Installez le MPPT ProStar dans un endroit qui empêche le contact occasionnel. Le dissipateur de chaleur TriStar-PWM peut devenir très chaud pendant 2 IMPORTANT SAFETY INSTRUCTIS 3 MORNINGSTAR CORPORATI

5 le fonctionnement. Utilisez des outils isolés pour travailler avec les batteries. Évitez le port de bijoux pendant l installation. Le groupe de batteries doit être constitué de batteries du même type, fabricant et âge. UL/IEC certifié pour utilisation au négatif à la masse ou les systèmes flottants seulement. Ne fumez pas à proximité du groupe de batteries. Les connexions d alimentation doivent rester serrées pour éviter une surchauffe excessive d une connexion desserrée. Utilisez des conducteurs et des coupe-circuits de dimensions adaptées. La borne de mise à la terre se trouve dans le compartiment de câblage et est identifiée par le symbole ci-dessous: Ces connexions CC sont identifiées par le symbole ci-dessous: WARNING: A battery can present a risk of electrical shock or burn from large amounts of short-circuit current, fire, or explosion from vented gases. Observe proper precautions. AVERTISSEMENT: Une batterie peut présenter a risque de choc électrique ou de brûlure de grandes quantités de court-circuit curlouer, incendie ou explosion de ventilé gaz. Observer précautions appropriées. WARNING: Risk of Explosion. Proper disposal of batteries is required. Do not dispose of batteries in fire. Refer to local regulations or codes for requirements. AVERTISSEMENT: Risque d Explosion. Au rebut des piles est nécessaire. Ne pas jeter les piles dans le feu. Se référer aux réglementations locales ou des codes pour les exigences. CAUTI: When replacing batteries, use properly specified number, sizes, types, and ratings based on application and system design. PRUDENCE: Lorsque le remplacement des piles, utilisez correctement nombre spécifié, tailles, types et les évaluations basées sur conception de système et d application. CAUTI: Do not open or mutilate batteries. Released electrolyte is harmful to skin, and may be toxic. PRUDENCE: Ne pas ouvrir ou mutiler les piles. L électrolyte est nocif pour la peau et peut être toxique. Servicing of batteries should be performed, or supervised, by personnel knowledgeable about batteries, and the proper safety precautions. Be very careful when working with large lead-acid batteries. Wear eye protection and have fresh water available in case there is contact with the battery acid. Remove watches, rings, jewelry and other metal objects before working with batteries. Wear rubber gloves and boots Use tools with insulated handles and avoid placing tools or metal objects on top of batteries. Disconnect charging source prior to connecting or disconnecting battery terminals. Determine if battery is inadvertently grounded. If so, remove the source of contact with ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such a shock can be reduced if battery grounds are removed during installation and maint enance (applicable to equipment and remote battery supplies not having a grounded supply circuit). Carefully read the battery manufacturer s instructions before installing / connecting to, or removing batteries from, the TriStar-PWM. Be very careful not to short circuit the cables connected to the battery. Have someone nearby to assist in case of an accident. Explosive battery gases can be present during charging. Be certain there is enough ventilation to release the gases. Never smoke in the battery area. If battery acid comes into contact with the skin, wash with soap and water. If the acid contacts the eye, flood with fresh water and get medical attention. Be sure the battery electrolyte level is correct before starting charging. Do not attempt to charge a frozen battery. Recycle the battery when it is replaced. 4 IMPORTANT SAFETY INSTRUCTIS 5 MORNINGSTAR CORPORATI

6 Entretien des batteries devrait être effectué ou supervisé, par un personnel bien informé sur les piles et les précautions de sécurité appropriées. Soyez très prudent quand vous travaillez avec des grandes batteries au plomb. Portez des lunettes de protection et ayez de l eau fraîche à disposition en cas de contact avec l électrolyte. Enlevez les montres, bagues, bijoux et autres objets mé talliques avant de travailler avec des piles. Porter des bottes et des gants de caoutchouc Utiliser des outils avec poignées isolantes et évitez de placer des outils ou des objets métalliques sur le dessus de batteries. Débrancher la source de charge avant de brancher ou dis reliant les bornes de la batterie. Utilisez des outils isolés et évitez de placer des objets métalliques dans la zone de travail. Déterminer si batterie repose par inadvertance. Dans l affirmative, supprimer la source du contact avec le sol. Contact avec n importe quelle partie d une batterie mise à la terre peut entraîner un choc électrique. La probabilité d un tel choc peut être réduite si des motifs de batterie sont supprimés pendant l installation et maintentretien (applicable à l équipement et les fournitures de pile de la télécommande n ayant ne pas un circuit d alimentation mise à la terre). Lisez attentivement les instructions du fabricant de la batterie avant d installer / connexion à ou retrait des batteries du TriStar-PWM. Veillez à ne pas court-circuiter les câbles connectés à la batterie. Ayez une personne à proximité qui puisse aider en cas d accident. Des gaz explosifs de batterie peuvent être présents pendant la charge. Assurez-vous qu une ventilation suffisante évacue les gaz. Ne fumez jamais dans la zone des batteries En cas de contact de l électrolyte avec la peau, lavez avec du savon et de l eau. En cas de contact de l électrolyte avec les yeux, rincez abondamment avec de l eau fraîche et consultez un médecin. Assurez-vous que le niveau d électrolyte de la batterie est correct avant de commencer la charge. Ne tentez pas de charger une batterie gelée. Recyclez la batterie quand elle est remplacée. 1.0 TriStar Description The TriStar is a technically advanced solar system controller. There are three operating modes programmed into each TriStar. This manual describes solar battery charging, and specific load control or diversion charge control instructions are inserted where required. This manual will help you to become familiar with the TriStar s features and capabilities. Some of these follow: ETL Listed (UL 1741) and cetl Listed (CSA-C22.2 No ) TUV Listed (IEC 62109) Complies with the US National Electrical Code Complies with the Canadian Electrical Code Complies with EMC and LVD standards for CE marking Rated for 12, 24, 48 volt systems, and 45 or 60 amps current Fully protected with automatic and manual recovery Seven standard charging or load programs selected with switches Adjustability by means of an RS-232 connection with PC software Continuous self-testing with fault notification LED indications and push-button functions Terminals sized for 35mm 2 (#2 AWG) wire Includes battery voltage sense terminals Digital meter options (mounted to TriStar or remote) Optional remote battery temperature sensor 5-year warranty (see Section 10.0) 1.1 Versions and Ratings There are two standard versions of TriStar controllers: TriStar-45: Rated for maximum 45 amps continuous current (solar, load or diversion load) Rated for 12, 24, 48 Vdc systems TriStar-60: Rated for maximum 60 amps continuous current (solar, load or diversion load) Rated for 12, 24, 48 Vdc systems TriStar-60M: Rated for maximum 60 amps continuous current (solar, load or diversion load) Rated for 12, 24, 48 Vdc systems Includes on-board meter display 1.2 Operating Modes There are three distinct and independent operating modes programmed into each TriStar. Only one mode of operation can be selected for an individual TriStar. If a system requires a charging controller and a load controller, two TriStars must be used IMPORTANT SAFETY INSTRUCTIS 7 MORNINGSTAR CORPORATI

7 1.3 Adjustibility Eight switches permit the following parameters to be adjusted at the installation site: switch Solar Battery Charging 1 Battery charge control mode 2-3 Select battery voltage 4-6 Standard battery charging programs 7 Manual or automatic equalization 8 PWM charging or on-off charging switch Load Control 1 DC load control mode 2-3 Select battery voltage 4-6 Standard low voltage disconnects and reconnects 7 not used for load control 8 not used for load control switch Diversion Charge Control 1 DC load control mode 2-3 Select battery voltage 4-6 Standard diversion charge control programs 7 Select diversion charge control mode 8 Manual or automatic equalization In addition to the switches, the TriStar provides for additional adjust ments using a PC program. An RS-232 connection between the TriStar and a personal computer will enable extensive adjustments using PC software from Morningstar s website. 1.4 General Use NOTE: This manual describes solar battery charging. Specific instructions for the load control and diversion charge control modes are provided as notes throughout this manual. Solar overloads up to 130% of rated current will be tapered down instead of disconnecting the solar. Over-temperature conditions will also taper the solar input to lower levels to avoid a disconnect. The NEC requires overcurrent protection externally in the system (see Section 2.3 step 6). There are no system disconnects inside the TriStar enclosure. Any number of TriStars can be connected in parallel to increase solar charging current. TriStars can be paralleled LY in the battery charging mode. DO NOT parallel TriStars in the load mode, as this can damage the controller or load. The TriStar enclosure is rated for indoor use. The controller is protected by conformal coated circuit boards, stainless steel hardware, anodized aluminum, and a powder coated enclosure, but it is not rated for corrosive environments or water entry. The construction of the TriStar is 100% solid state. Battery charging is by a series PWM constant current charging, with bulk charging, PWM absorption, float and equalization stages. The TriStar will accurately measure time over long intervals to manage events such as automatic equalizations or battery service notification. Day and night conditions are detected by the TriStar, and no blocking diodes are used in the power path. LEDs, a push-button, and optional digital meters provide both status information and various manual operations. The date of manufacture can be found on the two bar code labels. One label is on the back of the TriStar, and the other is in the wiring compartment. The year and week of manufacture are the first four digits of the serial number. For example: year week serial # REMARQUE : Ce manuel décrit la charge de batteries solaires. Des instructions spécifiques aux modes de contrôle du chargement et de contrôle de la charge de diversion figurent en tant que remarques dans ce manuel. The TriStar is suitable for a wide range of solar applications including homes, telecom and industrial power needs. TriStar controllers are configured for negative ground systems. There are no parts in the controller s negative leg. The enclosure can be grounded using the ground terminal in the wiring compartment. The TriStar is protected from faults electronically with automatic recovery. There are no fuses or mechanical parts inside the TriStar to reset or change. 8 TRISTAR DESCRIPTI 9 MORNINGSTAR CORPORATI

8 1.5 Safety and Regulatory Information NOTE: This section contains important information for safety and regulatory requirements. REMARQUE : Cette section contient des informations importantes relatives à la sécurité et aux obligations réglementaires. The TriStar controller is intended for installation by a qualified technician according to electrical rules of each country in which the product will be installed. TriStar controllers comply with the following EMC standards: Immunity: EN : 2006; EN : 2009 Emissions: CISPR 22: 2008 Safety: EN and EN (battery chargers) A means shall be provided to ensure all pole disconnection from the power supply. This disconnection shall be incorporated in the fixed wiring. Using the TriStar grounding terminal (in the wiring compartment), a perman ent and reliable means for grounding shall be provided. The clamping of the earthing shall be secured against accidental loosening. The entry openings to the TriStar wiring compartment shall be protected with conduit or with a bushing. FCC requirements: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Morningstar for compliance could void the user s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada. 1.6 Optional Accessories Remote Temperature Sensor (RTS) If the temperature of the system battery varies more than 5 C (9 F) during the year, temperature compensated charging should be considered. Because the battery s chemical reactions change with temperature, it can be important to adjust charging to account for the temperature effects. The RTS will measure the battery temperature, and the TriStar uses this input to adjust the charging as required. The battery charging will be corrected for temperature as follows: 12 V battery Volts per C ( 0.017V per F) 24 V battery Volts per C ( 0.033V per F) 48 V battery Volts per C ( 0.067V per F) The RTS should be used only for battery charging and diversion control. Do not use the RTS for load control. The charging parameters that are adjusted for temperature include: PWM regulation Equalization Float High Voltage Disconnect See Installation, Step 4, for connecting the RTS to the TriStar. Digital Meter Displays Two digital meters can be added to the TriStar at any time during or after installation. One version is mounted on the controller (TS-M), the other is suitable for remote locations (TS-RM). The manual for installation and operation of the meter displays is included with the meter. The display is a 2x16 LCD meter with backlighting. Four push-buttons are used to scroll through the displays and to execute manual functions. There are a series of display screens that provide information such as: operating information and data operating bar charts (voltage and current) alarms and faults diagnostics settings In addition, there are various manual functions built into the meter. For example, the meter can be used to reset Ah data or start/stop equalizations. One of 5 languages can be selected for the meter. Ethernet Communications Adapter (EMC-1) This product is an Ethernet gateway that provides web monitoring services, a Modbus TCP/IP server, and a local web page server. End users can collect information about their off-grid PV system remotely. One EMC-1 supports all products with MeterBus ports by bridging MODBUS TCP/IP requests to serve LiveView pages for each product. USB Communications Adapter (UMC-1) A modular unit that uses a USB-B plug, usually from a USB A-B computer cable, and an RJ-11 plug to connect with a Morningstar controller s MeterBus port, for monitoring and programming using MSView PC software. 10 TRISTAR DESCRIPTI 11 MORNINGSTAR CORPORATI 1.0

9 2.0 TriStar Installation The installation instructions describe solar battery charging. Specific instructions for the load control and diversion modes are provided as notes. 2.1 General Information The mounting location is important to the performance and operating life of the controller. The environment must be dry and protected as noted below. The controller may be installed in a ventilated enclosure with sealed batteries, but never in a sealed battery enclosure or with vented batteries. If the solar array exceeds the current rating of the controller, multiple TriStars can be installed in parallel. Additional parallel controllers can also be added in the future. The load controllers cannot be used in parallel. To parallel diversion controllers, refer to Morningstar s website. If solar charging and load control are both required, two separate controllers must be used. Stranded wires to be connected to the terminals should be prepared first with e.g. clamped copper heads, etc. to avoid the possibility of one conductor free out of the connection screw, and possible contact with the metal enclosure. WARNING: Solar and battery fuses or DC breakers are required in the system. These protection devices are external to the controller, and must be a maximum of 70 amps for the TriStar-PWM-45, and 90 amps for the TriStar-PWM-60/M. 2.2 Installation Overview The installation is straightforward, but it is important that each step is done correctly and safely. A mistake can lead to dangerous voltage and current levels. Be sure to carefully follow each instruction in Section 2.3 and observe all cautions and warnings. The following diagrams provide an overview of the connections and the proper order. Load or Solar Array Battery + Solar + / Load Sense + Battery RTS (Not for Load) Battery 2.0 AVERTISSEMENT: Solaire et batterie fusibles ou disjoncteurs DC sont nécessaires dans le système. Ces dispositifs de protection sont externes au contrôleur, et doivent être un maximum de 70 ampères pour le TriStar-PWM-45, et 90 ampères pour le TriStar-PWM-60/M. WARNING: Installation must comply with all US National Electrical Code and Canadian Electrical Code requirements. Breakers and fuses may require lower ratings than referenced above, so as not to exceed any specific wire ampacity. AVERTISSEMENT: Installation doit être conforme à toutes les requirments US National Electrical Code et Code Canadien d'electricité. Disjoncteurs et fusibles peuvent exiger des cotes inférieures que mentionnés ci-dessus de manière à ne pas pour dépasser n'importe quel fils particulier admissible. Maximum battery short-circuit current rating must be less than the interrupt current rating of the battery over-current protection device referenced above. Solar / Load Figure 2.2a Installation Wiring for Solar Charging and Load Control Step Solar Charging and Load Control 1. Remove the access cover 2. Mount the TriStar using the enclosed template. 3. Adjust the 8 switches in the switch. Each switch must be in the correct position. 4. Attach the RTS if battery charging will be temperature compensated (not for load control). 5. Connect battery voltage sense wires (recommended). 6. Connect the battery power wires to the TriStar. Then connect the solar array wires (or load). 7. Connect a computer to the TriStar if making adjustments with PC software. 8. Replace the cover. 12 TRISTAR INSTALLATI 13 MORNINGSTAR CORPORATI

10 Hydro Wind Solar Source + Source Battery Figure 2.2b Installation Wiring for Diversion Charge Control NOTE: TriStar negative terminals are common negative. + Steps #3 and #6 are required for all installations. Steps #4, #5, and #7 are optional. Step Diversion Charge Control 1. Remove the access cover 2. Mount the TriStar using the enclosed template. 3. Adjust the 8 switches in the switch. Each switch must be in the correct position. 4. Attach the RTS if battery charging will be temperature compensated. 5. Connect battery voltage sense wires (recommended). 6. Connect the battery power wires to the TriStar. Then connect the diversion load wires. Sense + Battery RTS Battery Diversion Diversion + Recommended tools: wire cutter phillips screwdrivers wire stripper torque wrench (to 50 in-lb) slotted screw drivers flashlight Before starting the installation, review these safety notes: Do not exceed a battery voltage of 48V nominal (24 cells). Do not use a battery less than 12V (6 cells). Do not connect a solar input greater than a nominal 48V array for battery charging. Never exceed a Voc (open-circuit voltage) of 125V. Charge only 12, 24, or 48 volt lead-acid batteries when using the standard battery charging programs in the TriStar. Verify the nominal charging voltage is the same as the nominal battery voltage. Do not install a TriStar in a sealed compartment with batteries. Never open the TriStar access cover unless both the solar and battery power has been disconnected. Never allow the solar array to be connected to the TriStar with the battery disconnected. This can be a dangerous condition with high open-circuit solar voltages present at the terminals. Follow the installation steps in order: #1 through #8 Step 1 - Remove the Cover Remove the 4 screws in the front cover. Lift the cover until the top edge clears the heat sink, and set it aside. If an LCD meter display is attached to the cover, disconnect the RJ-11 connector at the meter for access. CAUTI: Do not remove the cover if power is present at any of the terminals. Verify that all power sources to the controller are disconnected. PRUDENCE : N enlevez pas le couvercle en cas de tension à une des bornes. Vérifiez que toutes les sources d alimentation au contrôleur sont déconnectées. Step 2 - Mounting Locate the TriStar on a wall protected from direct sun, high temperatures, and water. Do not install in a confined area where battery gasses can accumulate. 2.0 Step Diversion Charge Control (continued) 7. Connect a computer to the TriStar if making adjustments with PC software. 8. Replace the cover. 2.3 Installation Steps The TriStar controller must be installed properly and in accordance with the local and national electrical codes. It is also important that the installation be done safely, correctly and completely to realize all the benefits that the TriStar can provide for your solar system. Refer to Sections 4.0 and 9.0 for information about the TriStar s standard battery charging programs and general charging needs for different battery types. Refer to Section 5.0 for load control information, and Section 6.0 for diversion. NOTE: When mounting the TriStar, make sure the air flow around the controller and heat sink is not obstructed. There should be open space above and below the heat sink, and at least 75 mm (3 inches) clearance around the heat sink to allow free air flow for cooling. REMARQUE : Lors du montage du TriStar, assurez-vous que l écoulement d air autour du contrôleur et du puits de chaleur n est pas obstrué. Un espace doit se trouver au-dessus et en dessous du puits de chaleur et un dégagement de 75 mm (3 po) doit exister autour du puits de chaleur pour permettre l écoulement de l air à des fins de refroidissement. Before starting the installation, place the TriStar on the wall where it will be mounted and determine where the wires will enter the controller (bottom, side, back). Remove the appropriate knockouts before mounting the controller. The knockouts are sized for 1 inch and 1.25 inch conduit. 14 TRISTAR INSTALLATI 15 MORNINGSTAR CORPORATI

11 REMARQUE : Les instructions ci-dessous concernent la charge de batteries solaires. Reportez-vous à l Annexe 1 pour les réglages du commutateur de contrôle de charge et à l Annexe 2 pour les réglages du commutateur de contrôle de charge de diversion. The switches are located behind the negative power terminals. Each switch is numbered. The solar battery charging functions that can be adjusted with the switches follow: (10.25) (7.47) 45.7 (1.80) 25.4 (1.00) 15.2 (0.60) Control Mode/ Battery Charging (1) System Voltage (2,3) Battery Charging Algorithm (4,5,6) mm (inches) Figure Step 2 Mounting Dimensions 41.9 (1.65) 16.8 (0.66) 85.1 (3.35) (4.35) (5.00) Step 2 - Mounting (continued) Refer to Figure 2.3. Use the template provided in the shipping carton for locating the mounting holes and for stripping the wires. Use two of the #10 screws provided for the two keyhole slots. Leave the screw heads protruding enough to lock inside the keyhole slots (about 3.8 mm / inch). Mount the controller and pull it down to lock the screws into the slots. Use the remaining two screws to fasten the controller to the wall. Provide for strain relief for the bottom knockouts if conduit will not be used. Avoid excessive pulling forces on the terminals from the wires. Step 3 - Adjust the Switches An 8-position switch is used to set-up the controller for its intended use. All major functions can be set with the switches. See Section 7.0 for additional custom settings using PC software. Battery Equalization (7) Noise Reduction (8) Figure Step 3 Switch Functions As shown in the diagram, all the positions are in the position except switch numbers 7 and 8, which are in the position. NOTE: The switches should be changed only when there is no power to the controller. Turn off disconnect switches and remove all power to the controller before changing a switch. A fault will be indicated if a switch is changed while the controller is powered. REMARQUE : Les commutateurs ne doivent être remplacés que si le contrôleur est hors tension. Mettez tous les interrupteurs sur arrêt et mettez le contrôleur hors tension avant de changer un commutateur. Une panne sera indiquée en cas de changement d un commutateur alors que le contrôleur est sous tension. CAUTI: The TriStar is shipped with all the switches in the position. Each switch position must be confirmed during installation. A wrong setting could cause damage to the battery or other system components. PRUDENCE : Le TriStar est expédié avec tous les interrupteurs en position «ARRÊT». La position de chaque interrupteur doit être confirmée pendant l installation. Un mauvais réglage peut endommager la batterie ou d autres composants du système. NOTE: The instructions below are for solar battery charging. Refer to Appendix 1 for Load Control switch settings, and Appendix 2 for Diversion Charge Control switch settings. 16 TRISTAR INSTALLATI 17 MORNINGSTAR CORPORATI

12 The switch settings described below are for Solar Battery Charging only. Load and Diversion switch settings can be found in Appendixes 1 and 2. The switches are shipped in the position. With the switches in the position, the following functions are present: Switch Function 1 Battery charge mode 2, 3 Auto voltage select 4, 5, 6 Lowest battery charging voltage 7 Manual equalization 8 Normal PWM charging mode To configure your TriStar for the battery charging and control you require, follow the switch adjustments described below. To change a switch from to, slide the switch up toward the top of the controller. Make sure each switch is fully in the or position. Switch Number 1 - Control Mode: Solar Battery Charging Control Switch 1 Charging Off Load On Switches Number 2,3 - System Voltage: Voltage Switch 2 Switch 3 Auto Off Off 12 Off On 24 On Off 48 On On Auto Select 12 Volts Figure Step 3 Switches # 2,3 24 Volts 48 Volts The auto voltage selection occurs when the battery is connected and the TriStar starts-up. There should be no loads on the battery that might cause a discharged battery to indicate a lower system voltage. The switch selectable voltages are for 12V, 24V or 48V lead-acid batteries. Although the auto voltage selection is very dependable, it is recommended to use the switches to secure the correct system voltage. 2.0 Figure Step 3 Switch #1 For the Solar Battery Charging control mode, leave the switch in the position as shown. Switches Number 4,5,6 - Battery Charging Algorithm: Battery Type PWM Switch 4 Switch 5 Switch Off Off Off Off Off On Off On Off Off On On On Off Off On Off On On On Off 8 Custom On On On PWM 14.0V PWM 14.6V PWM 14.15V PWM 14.8V PWM 14.35V PWM 15.0V PWM 14.4V Custom Figure Step 3 Switch # 4,5,6 18 TRISTAR INSTALLATI 19 MORNINGSTAR CORPORATI

13 Select one of the 7 standard battery charging algorithms, or select the custom switch for special custom settings using the PC software. Refer to Section 9.0 of this manual for battery charging information. The 7 standard charging algorithms above are described in Section Standard Battery Charging Programs. Switch Number 7 - Battery Equalization: Equalize Switch 7 Manual Off Auto On Manual Figure Step 3 Switch # 7 In the Auto Equalization mode (switch #7 On), battery equalization will automatically start and stop according to the battery program selected by the switches 4,5,6 above. See Section 4.0 for detailed information about each standard battery algorithm and the equalization. In the Manual Equalization mode (switch #7 Off), equalization will occur only when manually started with the push-button. Automatic starting of equalization is disabled. The equalization will automatically stop per the battery algorithm selected. In both cases (auto and manual mode), the push-button can be used to start and stop battery equalization. LOAD CTROL switch settings are in Appendix 1. DIVERSI CHARGE CTROL switch settings are in Appendix 2. NOTE: Confirm all dip-switch settings before going to the next installation steps. REMARQUE : Confirmez les réglages de tous les commutateurs dip avant de passer aux étapes suivantes d installation. Step 4 - Remote Temperature Sensor (RTS) For solar battery charging and diversion load control, a remote temperature sensor (RTS) is recommended for effective temperature compensated charging. This remote temperature probe should not be installed for dc load control. The optional Morningstar RTS is connected to the 2-position terminal located between the push-button and the LEDs. See the diagram below: Switch Number 8 - Noise Reduction: Charging Switch 8 PWM Off On-Off On PWM Figure 2.9- Step 3 Switch # 8 The PWM battery charging algorithm is standard for all Morningstar charge controllers. However, in cases where the PWM regulation causes noise interference with loads (e.g. some types of telecom equipment or radios), the TriStar can be converted to an On-Off method of solar charge regulation. It should be noted that the On-Off solar charge regulation is much less effective than PWM. Any noise problem should be suppressed in other ways, and only if no other solution is possible should the TriStar be changed to an On-Off charger. Figure Step 4 RTS Connection The RTS is supplied with 10 meters (33 ft) of 0.34 mm 2 (22 AWG) cable. There is no polarity, so either wire (+ or ) can be connected to either screw terminal. The RTS cable may be pulled through the conduit with the power wires. Tighten the connector screws with 0.56 Nm (5 in-lb) of torque. Refer to the installation instructions provided with the RTS. WARNING: Risk of Fire. If no Remote Temperature Sensor (RTS) is connected, use the TriStar-PWM within 3m (10 ft) of the batteries. Internal Temperature Compensation will be used if the RTS is not connected. Use of the RTS is strongly recommended. 20 TRISTAR INSTALLATI 21 MORNINGSTAR CORPORATI

14 AVERTISSEMENT: Risque d incendie. Si non Capteur de température distant (RTS) est connecté, utilisez le TriStar-PWM moins de 3m (10 pi) de les batteries. Compensation de la température interne sera utilisée si la RTS n est pas connecté. Utilisation de la RTS est fortement recommandé. NOTE: Never place the temperature sensor inside a battery cell. Both the RTS and the battery will be damaged. REMARQUE : Ne placez jamais la sonde de température dans un élément de batterie. Le RTS et la batterie seraient endommagés. Step 5 - Battery Voltage Sense Connection A battery voltage sense connection is not required to operate your TriStar controller, but it is recommended for best performance in all charging and load control modes. The battery voltage sense wires carry almost no current, so the voltage sense input avoids the large voltage drops that can occur in the battery power conductors. The voltage sense connection allows the controller to measure the actual battery voltage under all conditions. In addition, if a TriStar meter will be added to the controller, the battery voltage sense will ensure that the voltage and diagnostic displays are very accurate. The two battery voltage sense wires are connected to the TriStar at the 2-position terminal located between the push-button and the positive (+) terminal lug. See the diagram below: Battery Figure Step 5 Battery Sense Connection The two voltage sense wires (not provided with the controller) should be cut to length as required to connect the battery to the voltage sense terminal. The wire size can be from 1.0 to 0.25 mm 2 (16 to 24 AWG). It is recom mended to twist the wires together every few feet (twisted pair), but this is not required. The voltage sense wires may be pulled through the conduit with the power wires. Fuse the positive (+) voltage sense wire as close to the battery as possible. Size the fuse based on wire ampacity - a 1A fuse can be used for #24 wire. Tighten the connector screws with 0.56 Nm (5 in-lb) of torque. The maximum length allowed for each battery voltage sense wire is 30 meters (98 ft). The battery sense terminal has polarity. Be careful to connect the battery positive (+) terminal to the voltage sense positive (+) terminal. No damage will occur if the polarity is reversed, but many functions of the controller can be affected. If a TriStar meter is installed, check the TriStar Settings to confirm the Voltage Sense and the RTS (if installed) are both present and seen by the controller. The PC software can also be used to confirm the voltage sense is working correctly. Do not connect the voltage sense wires to the RTS terminal. This may cause an alarm. Review the installation diagram for the correct battery voltage sense connection. Note that the battery voltage sense connection does not power (start-up) the controller. Step 6 - System Wiring and Power-Up To comply with the NEC, the TriStar must be installed using wiring methods in accordance with the latest edition of the National Electric Code, NFPA 70. Wire Size The four large power terminals are sized for mm 2 (2-14 AWG) wire. The terminals are rated for copper and aluminum conductors. Good system design generally requires large conductor wires for the solar and battery connections that limit voltage drop losses to 3% or less. The following table provides the maximum wire length (1-way distance / 2-wire pair) for connecting the battery, solar array or load to the TriStar with a maximum 3% voltage drop. Wire Size 60 Amps 45 Amps 30 Amps 15 Amps 95 mm m m m m (3/0 AWG) (42.2 ft.) (56.3 ft.) (84.4 ft.) (168.8 ft.) 70 mm m m m m (2/0 AWG) (33.4 ft.) (44.6 ft.) (66.8 ft.) (133.7 ft.) 50 mm m m m m (1/0 AWG) (26.6 ft.) (35.4 ft.) (53.1 ft.) (106.3 ft.) 35 mm m 6.83 m m m (2 AWG) (16.8 ft.) (22.4 ft.) (33.6 ft.) (67.2 ft.) 25 mm m 4.27 m 6.41 m m (4 AWG) (10.5 ft.) (14.0 ft.) (21.0 ft.) (42.1 ft.) 16 mm m 2.69 m 4.04 m 8.07 m (6 AWG) (6.6 ft.) (8.8 ft.) (13.2 ft.) (26.5 ft.) 10 mm m 1.70 m 2.54 m 5.09 m (8 AWG) (4.2 ft.) (5.6 ft.) (8.3 ft.) (16.7 ft.) 6 mm m 1.60 m 3.19 m (10 AWG) (3.5 ft.) (5.2 ft.) (10.5 ft.) 4 mm m 2.01 m (12 AWG) (3.3 ft.) (6.6 ft.) 2.5 mm m (14 AWG) (4.1 ft.) Table 2.3-6a Maximum 1-Way Wire Distance (12 Volts) 22 TRISTAR INSTALLATI 23 MORNINGSTAR CORPORATI 2.0

15 NOTES: The specified wire length is for a pair of conductors from the solar, load or battery source to the controller (1-way distance). Figures are in meters (m) and feet (ft). For 24 volt systems, multiply the 1-way length in the table by 2. For 48 volt systems, multiply the 1-way length in the table by 4. The NEC requires that manually operated disconnect switches or circuit breakers must be provided for connections between the TriStar and the battery. If the overcurrent devices being used are not manually operated disconnects, then manual disconnect switches must be added. These manual switches must be rated the same as the overcurrent devices noted above. Refer to the NEC for more information. Minimum Wire Size The NEC requires that the wires carrying the system current never exceed 80% of the conductors current rating. The table below provides the minimum size of copper wire allowed by NEC for the TS-45 and TS-60 versions. Wire types rated for 75 C and 90 C are included. Minimum wire sizes for ambient temperatures to 45 C are provided in the table below: TS-45 75C Wire 90C Wire TS-60 75C Wire 90C Wire 45C 16 mm 2 (6 AWG) 10 mm 2 (8 AWG) 45C 25 mm 2 (4 AWG) 16 mm 2 (6 AWG) Table 2.3-6b Minimum Wire Size Both copper and aluminum conductors can be used with a TriStar controller. If aluminum wire is used, the minimum size of the aluminum conductor must be one wire size larger than the minimum wire size specified in the table above. Ground Connection Use the grounding terminal in the wiring compartment to connect a copper wire to an earth ground or similar grounding point. The grounding terminal is identified by the ground symbol shown below that is stamped into the enclosure: Ground Symbol Per NEC (A) and NEC Table , minimum sizes for copper grounding wire are: TS-MPPT AWG (5 mm 2 ) TS-MPPT-60/M 8 AWG (8 mm 2 ) OR, of the same, or greater, cross-sectional area as the PV wires. Connect the Power Wires First, confirm that the switch #1 is correct for the operating mode intended. 24 TRISTAR INSTALLATI 25 MORNINGSTAR CORPORATI Battery + Solar + Solar Battery Load + Load Diversion + Diversion Figure Step 6 Power Wire Connections CAUTI: The solar PV array can produce open-circuit voltages over 100 Vdc when in sunlight. Verify that the solar input breaker has been opened (disconnected) before installing the system wires (if the controller is in the solar charging mode). PRUDENCE : Le réseau PV solaire peut produire des tensions de circuit ouvert supérieures à 100 V cc à la lumière du soleil. Vérifiez que le coupecircuit solaire a été ouvert (déconnexion) avant d installer les câbles du système (si le contrôleur est en mode de charge solaire). Using the diagram on the previous page, connect the four power conductors in the following steps: 1. Confirm that the input and output disconnect switches are both turned off before connecting the power wires to the controller. There are no disconnect switches inside the TriStar. 2. Provide for strain relief if the bottom knockouts are used and conduit is not used. 3. Pull the wires into the wiring compartment. The temperature probe wires and battery voltage sense wires can be inside the conduit with the power conductors. 4. Connect the Battery + (positive) wire to the Battery + terminal. 5. Connect the Battery (negative) wire to a TriStar common terminal. 6. Connect the Solar + wire (positive) to the Solar + terminal. (or Load + / Diversion +) 7. Connect the Solar (negative) wire a TriStar common terminal. (or Load / Diversion ) NOTE: TriStar negative terminals are common negative. The CE certification requires that the battery conductors, the battery voltage sense wires, and the remote temperature sensor shall not be accessible without the use of a tool and are protected in the battery compartment. 2.0

16 Do not bend the power wires up toward the access cover. If a TS-M meter is used now or in the future, these large wires can damage the meter assembly when the access cover is attached to the controller. Torque each of the four power terminals to 5.65 Nm (50 in-lbs). Power-Up Confirm that the solar (or load) and battery polarities are correct. Turn the battery disconnect on first. Observe the LEDs to confirm a successful start-up. (LEDs blink Green - Yellow - Red in one cycle) Note that a battery must be connected to the TriStar to start and operate the controller. The controller will not operate from a solar input only. Turn the solar (or load) disconnect on. 3.0 TriStar Operation The TriStar operation is fully automatic. After the installation is completed, there are few operator tasks to perform. However, the operator should be familiar with the basic operation and care of the TriStar as described below. 3.1 Operator s Tasks Use the push-button as needed (see 3.2 below) Check the LEDs for status and faults (see 3.3 below) Support recovery from a fault as required (see 3.4 below) Routine inspection and maintenance (see 3.6 below) Step 7 - RS-232 Adjustments The TriStar must be powered from the battery to enable use of the RS-232 / PC computer connection. Refer to Section 7.0 for using the RS-232 and Morningstar s PC software to change set-points or confirm the installation settings. Step 8 - Finish Installation Inspect for tools and loose wires that may have been left inside the enclosure. Check the power conductors to make sure they are located in the lower part of the wiring compartment and will not interfere with the cover or the optional meter assembly. NOTE: If the power conductors are bent upwards and touch the meter assembly (TS-M option), pressing the cover down on the wires can damage the meter. REMARQUE : Si les conducteurs d alimentation sont courbés vers le haut et touche l ensemble de mesure (option TS-M), la pression du couvercle sur les câbles peut endommager l appareil de mesure. Carefully place the cover back on the controller and install the 4 cover screws. Closely observe the system behavior and battery charging for 2 to 4 weeks to confirm the installation is correct and the system is operating as expected. If a TriStar digital meter is installed, please refer to the meter manual. 3.2 Push-button In the battery charging mode (both solar and diversion), the following functions can be enabled with the push-button (located on the front cover): PUSH: Reset from an error or fault. PUSH: Reset the battery service indication if this has been activated with the PC software. A new service period will be started, and the flashing LEDs will stop blinking. If the battery service is performed before the LEDs begin blinking, the push-button must be pushed at the time when the LEDs are blinking to reset the service interval and stop the blinking. PUSH AND HOLD 5 SECDS: Begin battery equalization manually. This will begin equalization in either the manual or automatic equalization mode. The equalization will automatically stop per the battery type selected (see Section 4.4). PUSH AND HOLD 5 SECDS: Stop an equalization that is in progress. This will be effective in either the manual or automatic mode. The equalization will be terminated. Note that if two or more TriStars are charging in parallel, the equalization cycles may start on different days for various reasons (such as one controller is disconnected and restarted). If this happens, the push-button on each controller can be used to manually start and then stop an equalization, and this will reset the equalizations to the same schedule. 3.0 LOAD & LIGHTING CTROL PUSH: Reset from an error or fault. PUSH AND HOLD 5 SECDS: After a low voltage disconnect (LVD) of the load, the push-button can be used to reconnect the loads again. The loads will remain on for 10 minutes, and will then disconnect again. The push-button can be used to override the LVD without limit. NOTE: The purpose of the LVD is to protect the battery. Repeated overrides of an LVD can deeply discharge the battery and may damage the battery. 26 TRISTAR INSTALLATI 27 MORNINGSTAR CORPORATI

17 3.3 LED Indications Valuable information can be provided by the three LEDs in the front cover. Although there are many different LED indications, they have similar patterns to make it easier to interpret each LED display. Consider as three groups of indications: General Transitions // Battery or Load Status // Faults. LED Display Explanation: G = green LED is lit Y = yellow LED is lit R = red LED is lit G/Y = Green and Yellow are both lit at the same time G/Y - R = Green & Yellow both lit, then Red is lit alone Sequencing (faults) has the LED pattern repeating until the fault is cleared 1. General Transitions: Controller start-up G - Y - R (one cycle) Push-button transitions blink all 3 LEDs 2 times Battery service is required all 3 LEDs blinking until service is reset 2. Battery Status General state-of-charge see battery SOC indications below PWM absorption G blinking (1/2 second on / 1/2 second off) Equalization state G fast blink (2 to 3 times per second) Float state G slow blink (1 second on / 1 second off) Battery State-of-Charge LED Indications (when battery is charging): G on 80% to 95% SOC G/Y on 60% to 80% SOC Y on 35% to 60% SOC Y/R on 0% to 35% SOC R on battery is discharging Refer to the Specifications (Section 11.0) for the State-of-Charge voltages. Another LED chart is provided at the end of this manual (Appendix 3) for easier reference. Note that because these State-of-Charge LED displays are for all battery types and system designs, they are only approximate indications of the battery charge state. LOAD & LIGHTING CTROL 2. Load Status 12V 24V 48V LVD+ 0.60V 1.20V 2.40V LVD+ 0.45V 0.90V 1.80V LVD+ 0.30V 0.60V 1.20V LVD+ 0.15V 0.30V 0.60V LVD The load status LEDs are determined by the LVD voltage plus the specified transition voltages. As the battery voltage rises or falls, each voltage transition will cause a change in the LEDs. 3. Faults & Alarms Short circuit - solar/load R/G - Y sequencing Overload - solar/load R/Y - G sequencing Over-temperature R - Y sequencing High voltage disconnect R - G sequencing Reverse polarity - battery no LEDs are lighted Reverse polarity - solar No fault indication switch fault R - Y - G sequencing Self-test faults R - Y - G sequencing Temperature probe (RTS) R/Y - G/Y sequencing Battery voltage sense R/Y - G/Y sequencing 3.4 Protections and Fault Recovery The TriStar protections and automatic recovery are important elements of the operating system. The system operator should be familiar with the causes of faults, controller protections, and any actions that may be required. Some basic fault conditions are reviewed below: Short circuit: (R/G-Y sequencing) When a short circuit occurs, the FET switches are opened in micro-seconds. The FETs will probably open before other protective devices in the system can react, so the short circuit may remain in the system. The TriStar will try to reconnect the FETs two times. If the short circuit remains, the LEDs will continue sequencing. After the short in the system is repaired, there are two ways to restart the controller: Power should have been disconnected to repair the short. When power is restored, the TriStar does a normal start-up and will reconnect the solar input or load. The push-button can also be used to reconnect the FET switches (if there is battery power to the TriStar). NOTE: There will always be a 10 second delay between attempts to reconnect the FET switches. Even if power is disconnected, the TriStar will wait for the remainder of the 10 seconds when the power is restored TRISTAR OPERATI 29 MORNINGSTAR CORPORATI

18 REMARQUE : Il existera toujours un délai de 10 secondes entre les tentatives de reconnexion des commutateurs TEC. Même si l alimentation est déconnectée, le TriStar attend la fin des 10 secondes quand l alimentation est rétablie. Solar overload: (R/Y-G sequencing) If the solar input exceeds 100% of the controller s current rating, the controller will reduce the average current below the TriStar s rating. The controller is capable of managing up to 130% of the rated solar input. When 130% rated current is exceeded, the solar will be disconnected and a fault will be indicated. The input FET switches will remain open for 10 seconds. Then the switches are closed again and charging resumes. These cycles can continue without limit. The current overload is reduced to the equivalent heating of the rated current input. For example, a 72A solar array (120% overload) will PWM down to 50A, which is equivalent to the heating from a normal 60A solar input. LOAD & LIGHTING CTROL Load overload: (R/Y-G sequencing) If the load current exceeds 100% of the controller s rating, the controller will disconnect the load. The greater the overload, the faster the controller will disconnect. A small overload could take a few minutes to disconnect. The TriStar will attempt to reconnect the load two times. Each attempt is at least 10 seconds apart. If the overload remains after 2 attempts, the load will remain disconnected. The overload must be corrected and the controller restarted. The push-button can also be used to reconnect the load. DIVERSI CHARGE CTROL Diversion overload: (R/Y-G sequencing) If the current to the diversion load exceeds the TriStar rating, the controller will attempt to reduce the load. If the overload is too large, the TriStar will disconnect the diversion load. The controller will continue attempts to reconnect the load. If the overload LEDs are sequencing, the diversion load is too large for the controller. The size of the load must be reduced. Reversed polarity: If the battery polarity is reversed, there will be no power to the controller and no LEDs will light. If the solar is reversed, the controller detects nighttime and there will be no LED indication and no charging. If the load is reversed, loads with polarity will be damaged. Be very careful to connect loads to the controller with correct polarity. See Section 5.4. switch fault: (R-Y-G sequencing) If a switch is changed while there is power to the controller, the LEDs will begin sequencing and the FET switches will open. The controller must be restarted to clear the fault. Solar high temperature: (R-Y sequencing) When the heatsink temperature limit is reached, the TriStar will begin reducing the solar input current to prevent more heating. If the controller continues heating to a higher temperature, the solar input will then be disconnected. The solar will be reconnected at the lower temperature (see Section 8.0). LOAD & LIGHTING CTROL Load high temperature: (R-Y sequencing) When the heatsink temperature limit is reached (90 C / 194 F), the TriStar will disconnect the load. The load will be reconnected at the lower temperature setting (70 C / 158 F). DIVERSI CHARGE CTROL Diversion high temperature: (R-Y sequencing) When the heat sink temperature reaches 80 C, the TriStar will change to an on-off regulation mode to reduce the temperature. If the temperature reaches 90 C, the load will be disconnected. The load is reconnected at 70 C. Solar high voltage disconnect (HVD): (R-G sequencing) If the battery voltage continues increasing beyond normal operating limits, the controller will disconnect the solar input (unless the FET switches cannot open due to a failure). See Section 11.0 for the disconnect and reconnect values. LOAD & LIGHTING CTROL Load HVD: (R-G sequencing) In the Load Control mode, the HVD can only be enabled using the PC software. At the battery voltage value selected in the software, the TriStar will disconnect the load. At the selected lower voltage, the load will be reconnected. DIVERSI CHARGE CTROL Diversion HVD: In the Diversion mode, an HVD condition will not be indicated with the LEDs, and there is no disconnect. An HVD condition will be indicated on the optional meter. Battery removal voltage spike: (no LED indication) Disconnecting the battery before the solar input is disconnected can cause a large solar open-circuit voltage spike to enter the system. The TriStar protects against these voltage spikes, but it is best to disconnect the solar input before the battery. Very low battery voltage: (LEDs are all off) Below 9 volts the controller will go into brownout. The controller shuts down. When the battery voltage rises, the controller will restart. In the Load Control mode, the TriStar will recover in the LVD state TRISTAR OPERATI 31 MORNINGSTAR CORPORATI

19 Remote temperature sensor (RTS) failure: (R/Y-G/Y) If a fault in the RTS (such as a short circuit, open circuit, loose terminal) occurs after the RTS has been working, the LEDs will indicate a failure and the solar input is disconnected. However, if the controller is restarted with a failed RTS, the controller may not detect that the RTS is connected, and the LEDs will not indicate a problem. A TriStar meter or the PC software can be used to determine if the RTS is working properly. Battery voltage sense failure: (R/Y-G/Y) If a fault in the battery sense connection (such as a short circuit, open circuit, loose terminal) occurs after the battery sense has been working, the LEDs will indicate a failure. However, if the controller is restarted with the failure still present in the battery sense, the controller may not detect that the battery sense is connected, and the LEDs will not indicate a problem. A TriStar meter or the PC software can be used to determine if the battery sense is working properly. 3.5 Data-Logging The TriStar records daily records of key system information. Data is stored in all operating modes: Charging, Load/Lighting, Diversion. In Charge mode records are written after dusk each day. In Load and Diversion modes, records are written every 24 hours and may not coincide with the natural day/ night cycle. The logged data can be viewed using the TriStar Digital Meter 2 or TriStar Remote Meter 2. Data can also be accessed using MSView TM PC software, which is available for download on our website. NOTE: The Data Logging feature is available in TriStar firmware version v12 and later. Firmware update files and instructions are available on our website. 3.6 Inspection and Maintenance WARNING: RISK OF ELECTRICAL SHOCK. NO POWER OR ACCESSORY TERMINALS ARE ELECTRICALLY ISOLATED FROM DC INPUT, AND MAY BE ENERGIZED WITH HAZARD- OUS SOLAR VOLTAGE. UNDER CERTAIN FAULT CDITIS, BATTERY COULD BECOME OVER-CHARGED. TEST BETWEEN ALL TERMINALS AND GROUND BEFORE TOUCHING. AVERTISSEMENT: RISQUE DE CHOC ÉLECTRIQUE. ALIMENTATI OU AUX BORNES D ACCESSOIRES ST ISOLÉS ÉLECTRIQUEMENT DE L ENTRÉE DE C.C ET DOIT ÊTRE ALIMENTÉS À UNE TENSI DANGEREUSE SOLAIRE. SOUS CER- TAINES CDITIS DE DÉFAILLANCE, LA BATTERIE POURRAIT DEVENIR TROP CHARGÉE. TEST ENTRE TOUTES LES BORNES ET LA MASSE AVANT DE TOUCHER. WARNING: Shock Hazard Disconnect all power sources to the controller before removing the wiring box cover. Never remove the cover when voltage exists on the TriStar-PWM power connections. AVERTISSEMENT: Risque de décharge électrique Un moyen de déconnexion de tous les poteaux d'alimentation doit être fourni. Ceux-ci se déconnecte doit être intégrée dans le câblage fixe. Ouvrir que toutes les source d'énergie se déconnecte avant de retirer le couvercle de la contrôleur, ou accès au câblage. The TriStar does not require routine maintenance. The following inspections are recommended two times per year for best long-term performance. 1. Confirm the battery charging is correct for the battery type being used. Observe the battery voltage during PWM absorption charging (green LED blinking 1/2 second on / 1/2 second off). Adjust for temperature compensation if an RTS is used (see Table 4.3). For load and diversion modes, confirm that the operation is correct for the system as configured. 2. Confirm the controller is securely mounted in a clean and dry environment. 3. Confirm that the air flow around the controller is not blocked. Clean the heat sink of any dirt or debris. 4. Inspect for dirt, nests and corrosion, and clean as required TRISTAR OPERATI 33 MORNINGSTAR CORPORATI

20 4.0 Battery Charging 4.1 PWM Battery Charging PWM (Pulse Width Modulation) battery charging is the most efficient and effective method for recharging a battery in a solar system. Refer to Why PWM? on Morningstar s website for more information. Selecting the best method for charging your battery together with a good maintenance program will ensure a healthy battery and long service life. Although the TriStar s battery charging is fully automatic, the following information is important to know for getting the best performance from your TriStar controller and battery Four Stages of Solar Charging VOLTAGE NIGHT EQUALIZE BULK CHARGE ABSORPTI FLOAT TIME NIGHT Battery Voltage Sense: Connecting a pair of voltage sense wires from the controller to the battery is recommended. This allows a precise battery voltage input to the controller and more accurate battery charging. See Section 4.3 for more information. Temperature Compensation: All charging set-points are based on 25 C (77 F). If the battery temperature varies by 5 C, the charging will change by 0.15 volts for a 12 volt battery. This is a substantial change in the charging of the battery, and a remote temperature sensor is recommended to adjust charging to the actual battery temperature. See Section 4.3 for more information. Day-Night Detection: The TriStar will automatically detect day and night conditions. Any functions that require measuring time or starting at dawn, for example, will be automatic. PWM Noise: In some installations, the PWM charging may cause audible noise in certain equipment. If this occurs, the PWM can be changed to On- Off solar charging to reduce the noise. This requires switch number 8 to be turned On. However, it is strongly recommended to try to remedy the noise problem with grounding or filtering first, because the benefits from PWM battery charging are significant. Battery Types: The TriStar s standard battery charging programs are suitable for a wide range of lead-acid battery types. These standard programs are reviewed in the following Section 4.2. A general review of battery types and their charging needs is provided in Section Figure Solar Charging Stages 1. Bulk Charging: In this stage, the battery will accept all the current provided by the solar system. The LEDs will display an indication of the battery charge state as the battery is being recharged. 2. PWM Absorption: When the battery reaches the regulation voltage, the PWM begins to hold the voltage constant. This is to avoid over-heating and over-gasing the battery. The current will taper down to safe levels as the battery becomes more fully charged. The green LED will blink once per second. See Section Equalization: Many batteries benefit from a periodic boost charge to stir the electrolyte, level the cell voltages, and complete the chemical reactions. The green LED will blink rapidly 2-3 times per second. See Section Float: When the battery is fully recharged, the charging voltage is reduced to prevent further heating or gasing of the battery. The green LED will blink slowly once every 2 seconds. See Section Battery Charging Notes The TriStar manages many different charging conditions and system configurations. Some useful functions to know follow below. Solar Overload: Enhanced radiation or edge of cloud effect conditions can generate more current than the controller s rating. The TriStar will reduce this overload up to 130% of rated current by regulating the current to safe levels. If the current from the solar array exceeds 130%, the controller will interrupt charging (see Section 3.4). 4.2 Standard Battery Charging Programs The TriStar provides 7 standard battery charging algorithms (programs) that are selected with the switches (see Step 3 in Installation). These standard algorithms are suitable for lead-acid batteries ranging from sealed (gel, AGM, maintenance free) to flooded to L-16 cells. In addition, an 8th switch provides for custom set-points using the PC software. The table below summarizes the major parameters of the standard charging algorithms. Note that all the voltages are for 12V systems (24V = 2X, 48V = 4X). All values are 25ºC (77ºF). A. B. C. D. E. F. G. PWM Time Equalize Max Equal. Switches Battery Absorp. Float Equal. in Equal. Interval Cycle (4-5-6) Type Voltage Voltage Voltage (hours) (days) (hours) off-off-off 1 - Sealed none off-off-on 2 - Sealed off-on-off 3 - Sealed off-on-on 4 - Flooded on-off-off 5 - Flooded on-off-on 6 - Flooded on-on-off 7 - L on-on-on 8 - Custom Custom Custom Table 4.2 Standard Battery Charging Programs 34 BATTERY CHARGING 35 MORNINGSTAR CORPORATI

21 A. Battery Type - These are generic lead-acid battery types. See Section 9.0 for more information about battery types and appropriate solar charging. B. PWM Voltage This is the PWM Absorption stage with constant voltage charging. The PWM voltage is the maximum battery voltage that will be held constant. As the battery becomes more charged, the charging current tapers down until the battery is fully charged. C. Float Voltage When the battery is fully charged, the charging voltage will be reduced to 13.4 volts for all battery types. The float voltage and transition values are adjustable with the PC software. See Section 4.5 for more details. D. Equalization Voltage During an equalization cycle, the charging voltage will be held constant at this voltage. E. Time in Equalization The charging at the selected equalization voltage will continue for this number of hours. This may take more than one day to complete. See Section 4.4. F. Equalization Interval Equalizations are typically done once a month. Most of the cycles are 28 days so the equalization will begin on the same day of the week. Each new cycle will be reset as the equalization starts so that a 28 day period will be maintained. G. Maximum Equalization Cycle If the solar array output cannot reach the equalization voltage, the equalization will terminate after this many hours to avoid over gasing or heating the battery. If the battery requires more time in equalization, the manual push-button can be used to continue for one or more additional equalization cycles. These (7) standard battery charging algorithms will perform well for the majority of solar systems. However, for systems with specific needs beyond these standard values, any or all of these values can be adjusted using the PC software. See Section Temperature Effects & Battery Voltage Sense Remote Temperature Sensor (RTS) The RTS is used for temperature compensated battery charging. As the battery gets warmer, the gasing increases. As the battery gets colder, it becomes more resistant to charging. Depending on how much the battery temperature varies, it may be important to adjust the charging for temperature changes. There are three battery charging parameters that are affected by temperature: PWM Absorption This is the most important part of charging that is affected by temperature because the charging may go into PWM absorption almost every day. If the battery temperature is colder, the charging will begin to regulate too soon and the battery may not be recharged with a limited solar resource. If the battery temperature rises, the battery may heat and gas too much. Equalization A colder battery will lose part of the benefit of the equalization. A warmer battery may heat and gas too much. Float Float is less affected by temperature changes, but it may also undercharge or gas too much depending on how much the temperature changes. The RTS corrects the three charging set-points noted above by the following values: 12 volt battery: volts per C ( volts per F) 24 volt battery: volts per C ( volts per F) 48 volt battery: volts per C ( volts per F) Variations in battery temperature can affect charging, battery capacity, and battery life. The greater the range of battery temperatures, the greater the impact on the battery. For example, if the temperature falls to 10 C (50 F) this 15 C (27 F) change in temperature will change the PWM, equalization and float set-points by 1.80V in a 48V system. If a remote temperature sensor is not used and the temperatures near the battery are stable and predictable, the PWM absorption setting can be adjusted using the PC software per the following table: Temperature 12 Volt 24 Volt 48 Volt 40ºC / 104ºF 0.45 V 0.90 V 1.80 V 35ºC / 95ºF 0.30 V 0.60 V 1.20 V 30ºC / 86ºF 0.15 V 0.30 V 0.60 V 25ºC / 77ºF 0 V 0 V 0 V 20ºC / 68ºF V V V 15ºC / 59ºF V V V 10ºC / 50ºF V V V 5ºC / 41ºF V V V 0ºC / 32ºF V V V 5ºC / 23ºF V V V 10ºC / 14ºF V V V 15ºC / 5ºF V V V Table 4.3 Temperature Compensation The need for temperature compensation depends on the temperature variations, battery type, how the system is used, and other factors. If the battery appears to be gasing too much or not charging enough, an RTS can be added at any time after the system has been installed. See Section Step 4 for installation instructions. The TriStar will recognize the RTS when the controller is started (poweredup) Battery Voltage Sense There can be voltage drops typically up to 3% in the power cables connect ing the battery to the TriStar. If battery voltage sense wires are not used, the controller will read a higher voltage at the controller s terminals than the actual battery voltage while charging the battery. Although limited to 3% as the generally accepted wiring standard, this can result in a 0.43 voltage drop for 14.4V charging (or 1.72V for a 48 volt nominal system). 36 BATTERY CHARGING 37 MORNINGSTAR CORPORATI 4.0

22 These voltage drops will cause some undercharging of the battery. The controller will begin PWM absorption, or limit equalization, at a lower battery voltage because the controller measures a higher voltage at the controller s terminals than is the actual battery voltage. For example, if the controller is programmed to start PWM absorption at 14.4V, when the controller sees 14.4V at its battery terminals, the true battery voltage would only be 14.1V if there is a 0.3V drop between the controller and battery. Two sense wires, sized from 1.0 to 0.25 mm 2 (16 to 24 AWG), can be used for battery voltage sense. Because these wires carry no current, the voltage at the TriStar will be identical to the battery voltage. A 2-position terminal is used for the connection Note that the battery sense wires will not power the controller, and the sense wires will not compensate for losses in the power wires between the con troller and the battery. The battery sense wires are used to improve the accuracy of the battery charging. See Section Step 5 for instructions how to connect the battery sense wires. 4.4 Equalization Routine equalization cycles are often vital to the performance and life of a battery particularly in a solar system. During battery discharge, sulfuric acid is consumed and soft lead sulfate crystals form on the plates. If the battery remains in a partially discharged condition, the soft crystals will turn into hard crystals over time. This process, called lead sulfation, causes the crystals to become harder over time and more difficult to convert back to soft active materials. Sulfation from chronic undercharging of the battery is the leading cause of battery failures in solar systems. In addition to reducing the battery capacity, sulfate build-up is the most common cause of buckling plates and cracked grids. Deep cycle batteries are particularly susceptible to lead sulfation. Normal charging of the battery can convert the sulfate back to the soft active material if the battery is fully recharged. However, a solar battery is seldom completely recharged, so the soft lead sulfate crystals harden over a period of time. Only a long controlled overcharge, or equalization, at a higher voltage can reverse the hardening sulfate crystals. In addition to slowing or preventing lead sulfation, there are also other benefits from equalizations of the solar system battery. These include: Balance the individual cell voltages. Over time, individual cell voltages can drift apart due to slight differences in the cells. For example, in a 12 cell (24V) battery, one cell is less efficient in recharging to a final battery voltage of 28.8 volts (2.4 V/c). Over time, that cell only reaches 1.85 volts, while the other 11 cells charge to 2.45 volts per cell. The overall battery voltage is 28.8V, but the individual cells are higher or lower due to cell drift. Equalization cycles help to bring all the cells to the same voltage. Mix the electrolyte. In flooded batteries, especially tall cells, the heavier acid will fall to the bottom of the cell over time. This stratification of the electrolyte causes loss of capacity and corrosion of the lower portion of the plates. Gasing of the electrolyte from a controlled overcharging (equalization) will stir and remix the acid into the battery electrolyte. NOTE: Excessive overcharging and gasing too vigorously can damage the battery plates and cause shedding of active material from the plates. An equalization that is too high or for too long can be damaging. Review the requirements for the particular battery being used in your system. REMARQUE : Une surcharge excessive et un dégagement gazeux trop vigoureux peuvent endommager les plaques de batteries et provoquer l élimination du matériau actif des plaques. Une compensation trop élevée ou trop longue peut provoquer des dégâts. Examinez les exigences pour la batterie particulière utilisée dans votre système Standard Equalization Programs Both automatic and manual equalizations can be performed using either the standard charging programs (see 4.2) or a custom program (see 7.0). Manual Equalization The TriStar is shipped with the switch set for manual equalization only. This is to avoid an unexpected or unwanted automatic equalization. In the manual mode, the push-button is used to both start or stop a manual equalization. Hold the push-button down for 5 seconds to start or stop an equalization (depending on whether an equalization is in progress or not). The LEDs will confirm the transition (all 3 LEDs blink 2 times). When the battery charging enters into equalization, the Green LED will start fast blinking 2-3 times per second. There are no limits to how many times the push-button can be used to start and stop equalizations. Equalizations will be terminated automatically per the charging program selected if the push-button is not used to manually stop the equalization. Automatic Equalization If the equalization switch is moved to the position (see Step 3), the equalizations will begin automatically per the charging program selected. Other than starting, the automatic and manual equalizations are the same and follow the standard charging program selected. The push-button can be used to start and stop equalizations in both the manual and automatic mode Typical Equalizations The automatic equalizations will occur every 28 days (except L-16 cells at 14 days). When an equalization begins (auto or manual), the battery charging voltage increases up to the equalization voltage (Veq). The battery will remain at Veq for the time specified in the selected charging program (see table in 4.2). If the time to reach Veq is too long, the maximum equalization cycle time will end the equalization. A second manual equalization cycle can be started with the push-button if needed. If the equalization cannot be completed in one day, it will continue the next day or days until finished. After an equalization is completed, charging will return to PWM absorption. 38 BATTERY CHARGING 39 MORNINGSTAR CORPORATI 4.0

23 4.4.3 Preparation for Equalization First, confirm that all your loads are rated for the equalization voltage. Consider that at 0 C (32 F) the equalization voltage will reach 16.05V in a 12V system (64.2V in a 48V system) with a temperature sensor installed. Disconnect any loads at risk. If Hydrocaps are used, be sure to remove them before starting an equalization. Replace the Hydrocaps with standard battery cell caps. The Hydrocaps can get very hot during an equalization. Also, if Hydrocaps are used, the equalization should be set for manual only ( switch #7 is Off). After the equalization is finished, add distilled water to each cell to replace gasing losses. Check that the battery plates are covered When to Equalize The ideal frequency of equalizations depends on the battery type (leadcalcium, lead-antimony, etc.), the depth of discharging, battery age, temperature, and other factors. One very broad guide is to equalize flooded batteries every 1 to 3 months or every 5 to 10 deep discharges. Some batteries, such as the L-16 group, will need more frequent equalizations. The difference between the highest cell and lowest cell in a battery can also indicate the need for an equalization. Either the specific gravity or the cell voltage can be measured. The battery manufacturer can recommend the specific gravity or voltage values for your particular battery. 4.5 Float When a battery becomes fully charged, dropping down to the float stage will provide a very low rate of maintenance charging while reducing the heating and gasing of a fully charged battery. When the battery is fully recharged, there can be no more chemical reactions and all the charging current is turned into heat and gasing. The purpose of float is to protect the battery from long-term overcharge. From the PWM absorption stage, charging is dropped to the float voltage. This is typically 13.4V, and is adjustable with the PC software. The transition to float is based on the previous 24 hour history. Factors include the battery voltage, the state of charge the night before, the battery type, and the PWM duty cycle and stability of the duty cycle. The battery will be charged for part of the day until the transition to float. If there are loads for various periods of time during float, the TriStar will cancel float and return to bulk charge. Float is temperature compensated Equalize a Sealed Battery? The standard battery charging table (see Section 4.2) shows two sealed batteries with an equalization cycle. This is only a 0.05 volt (12V battery) boost cycle to level individual cells. This is not an equalization, and will not vent gas from sealed batteries that require up to 14.4V charging (12V battery). This boost charge for sealed cells allows for adjustability with the PC software. Many VRLA batteries, including AGM and gel, have increased charging requirements up to 14.4V (12V battery). The 0.05V boost shown in the table (Section 4.2) is less than the accuracy range of most charge controllers. Alternatively, for these two sealed battery charging programs you may prefer to consider the PWM absorption stage to be 14.2V and 14.4V (12V battery). The 14.0, 14.2, and 14.4 volt standard charging programs should be suitable for most sealed batteries. If not optimum for your battery, the PC software can be used to adjust these values. Refer to Section 9.0 for more information about charging sealed batteries. 40 BATTERY CHARGING 41 MORNINGSTAR CORPORATI

24 5.0 Load and Lighting Control 5.1 General Load & Lighting Control Notes IMPORTANT: Inductive loads Do not connect inductive loads such as inverters, motors, pumps, compressors, generators to the load terminals. Inductive loads can generate large voltage spikes that may damage the controller s lightning protection devices. Connect inductive loads directly to the battery. If a heavy load must be connected to the TriStar's load terminals e.g. for LVD purposes, contact your dealer or Morningstar Tech Support for a design solution Parallel TriStars Two or more TriStars should never be put in parallel for a large load. The controllers cannot share the load Reverse Polarity If the battery is correctly connected (LEDs are on), the load should be connected very carefully with regard to polarity (+ / ). If the polarity is reversed, the controller cannot detect this. There are no indications. Loads without polarity will not be affected. Loads with polarity can be damaged. It is possible that the TriStar will go into short circuit protection before the load is damaged. If the LEDs indicate a short, be certain to check for both shorts and reversed polarity connections. If the controller does not go into short circuit protection, the loads with polarity will be damaged. CAUTI: Carefully verify the polarity (+ and ) of the load connections before applying power to the controller. PRUDENCE : Vérifiez avec précaution la polarité (+ et ) des connexions de la charge avant de mettre le contrôleur sous tension. 5.2 Load Control Settings The primary purpose of a low voltage load disconnect function (LVD) is to protect the system battery from deep discharges that could damage the battery. In the Load Control mode, the TriStar provides for seven standard LVD settings that are selected by the switches. These are described in the table below. Custom LVD settings are possible using the PC software (see Section 7.0). 12V 24V 48V Battery 12V 24V 48V Switch LVD LVD LVD SOC% LVD R LVD R LVD R off-off-off off-off-on off-on-off off-on-on on-off-off on-off-on on-on-off on-on-on Custom Custom Custom Table 5.1 The table above describes the standard selectable LVD battery voltages for 12, 24 and 48 volt systems. The LVD R values are the load reconnect setpoints. The Battery SOC % provides a general battery state-of-charge figure for each LVD setting. The actual battery SOC can vary considerably depending on the battery condition, discharge rates, and other specifics of the system. NOTE: The lowest LVD settings are intended for applications such as telecom that only disconnect the load as a last resort. These lower LVD settings will deeply discharge the battery and should not be used for systems that may go into LVD more than once a year. REMARQUE : Les réglages les plus bas du disjoncteur basse tension sont prévus pour les applications comme celles de télécom qui ne déconnectent la charge qu en dernier recours. Ces réglages les plus bas du disjoncteur basse tension déchargent fortement la batterie et ne doivent pas être utilisés avec les systèmes qui risquent de déclencher le disjoncteur basse tension plus d une fois par an. The LVD values in table 5.1 above are current compensated. Under load, the battery voltage will be reduced in proportion to the current draw by the load. A short-term large load could cause a premature LVD without the current compensation. The LVD values in the table above are adjusted lower per the following table: TS-45 TS-60 12V 15 mv per amp 10 mv per amp 24V 30 mv per amp 20 mv per amp 48V 60 mv per amp 40 mv per amp As an example, consider a 24V system using a TriStar-60 with a 30 amp load. The LVD will be reduced by 0.02V (per the table above) times 30 amps. This equals 0.6V. A -switch selected LVD of 23.4V would be reduced to 22.8V in this example. Note that the LEDs are linked to the LVD setting, so the LEDs are also current compensated. 5.0 continued LOAD CTROL 43 MORNINGSTAR CORPORATI

25 After an LVD, the load reconnect voltages are 0.25 volts per battery cell higher than the LVD (for example, in a 12V system the LVD R would be 1.5 volts above LVD). Battery voltages can rise quickly after an LVD, typically from 1.0 to 1.3 volts or more (12V system). The LVD R value must be high enough to avoid cycling in and out of LVD. 5.3 LVD Warning When the battery is discharging and the green LED changes to the next state (G-Y LEDs on), there are four remaining transitions to LVD (refer to the LED indications in Section 3.3). Each of these LED displays will serve as a warning of an approaching LVD. The final warning is a blinking red LED state. The amount of time from the initial G-Y display until the load disconnect will depend on many factors. These include: The rate of discharge. The health of the battery The LVD setting For a typical system with a healthy battery and an LVD setting of about 11.7 volts, there could be approximately 10 hours per LED transition. The LVD would occur about 40 hours from the first G-Y display (under constant load with no charging). Another significant factor affecting the warning time is the LVD voltage setpoint. Lower LVD voltage settings may result in the battery discharging 70% or 80% of its capacity. In this case, the battery s very low charge state will result in the voltage dropping much faster. At the lowest LVD settings, there could be as little as 2 or 3 hours of warning between LED transitions for a healthy battery. The amount of time it takes to transition through the LEDs to LVD can vary greatly for different systems. It may be worthwhile to measure the time it takes for your system to transition from one LED state to the next. Do this under typical discharging loads. This will provide a good reference for how long it will take for your system to reach LVD. It can also provide a benchmark for judging the health of your battery over time. 6.0 Diversion Charge Control The TriStar s third mode of operation is diversion load battery charge control. As the battery becomes fully charged, the TriStar will divert excess current from the battery to a dedicated diversion load. This diversion load must be large enough to absorb all the excess energy, but not too large to cause a controller overload condition. 6.1 Diversion Charge Control In the diversion mode, the TriStar will use PWM charging regulation to divert excess current to an external load. As the battery becomes fully charged, the FET switches are closed for longer periods of time to direct more current to the diversion load. As the battery charges, the diversion duty cycle will increase. When fully charged, all the source energy will flow into the diversion load if there are no other loads. The generating source is typically a wind or hydro generator. Some solar systems also use diversion to heat water rather than open the solar array and lose the energy. The most important factor for successful diversion charge control is the correct sizing of the diversion load. If too large, the controller s protections may open the FET switches and stop diverting current from the battery. This condition can damage the battery. If you are not confident and certain about the installation, a professional installation by your dealer is recommended. 6.2 Diversion Current Ratings The maximum diversion load current capability for the two TriStar versions is 45 amps (TS-45) and 60 amps (TS-60/M). The diversion loads must be sized so that the peak load current cannot exceed these maximum ratings. See section 6.4 below for selecting and sizing the diversion loads. The total current for all combined charging sources (wind, hydro, solar) should be equal or less than two-thirds of the controller s current rating: 30A (TS-45) and 40A (TS-60/M). This limit will provide a required margin for high winds and high water flow rates as well as a margin for error in the rating and selection of the diversion load. This protects against an overload and a safety disconnect in the TriStar controller, which would leave the battery charging unregulated. CAUTI: If the TriStar s rating is exceeded and the controller disconnects the diversion load, Morningstar will not be responsible for any damage resulting to the system battery or other system components. Refer to Morningstar s Limited Warranty in Section PRUDENCE : Si la capacité du TriStar est dépassée et que le contrôleur déconnecte la charge de diversion, Morningstar ne sera pas responsable de tout dommage résultant de la batterie du système ou d autres composants du système. Reportez-vous à la Garantie limitée de Morningstar dans la Section Standard Diversion Battery Charging Programs The TriStar provides 7 standard diversion charging algorithms (programs) that are selected with the switches. An 8th algorithm can be used for custom set-points using the PC software. The table below summarizes the major parameters of the standard diversion battery charging algorithms. Note that all the voltages are for 12V systems (24V = 2X, 48V = 4X) LOAD CTROL 45 MORNINGSTAR CORPORATI

26 All values (77ºF). A. B. C. Time D. E. F. G. Max. PWM Until Time Equalize Equalize Switches Absorp. Float Float Equalization in Equal. Interval Cycle (4-5-6) Voltage Voltage (hours) Voltage (hours) (days) (hours) off-off-off off-off-on off-on-off off-on-on on-off-off on-off-on on-on-off on-on-on Custom Custom Custom Table 6.1 Standard Diversion Charging Programs 6.4 Selecting the Diversion Load It is critical that the diversion load be sized correctly. If the load is too small, it cannot divert enough power from the source (wind, hydro, etc). The battery will continue charging and could be overcharged. If the diversion load is too large, it will draw more current than the rating of the TriStar. The controller s overload protection may disconnect the diversion load, and this will result in all of the source current going to the battery. CAUTI: The diversion load must be able to absorb the full power output of the source, but the load must never exceed the current rating of the TriStar controller. Otherwise, the battery can be overcharged and damaged. A. PWM Absorption Voltage - This is the PWM Absorption stage with constant voltage charging. The PWM absorption voltage is the maximum battery voltage that will be held constant. B. Float Voltage - When the battery is fully charged, the charging voltage will be reduced to the float voltage for all diversion settings. The float voltage and transition values are adjustable with the PC software. C. Time Until Float - This is the cumulative time in PWM before the battery voltage is reduced to the float voltage. If loads are present during the PWM absorption, the time to transition into float will be extended. D. Equalization Voltage - During an equalization cycle, the charging voltage will be held constant at this voltage. Equalizations are manual, and can be selected for automatic (See Section 4.4.1). E. Time in Equalization - Charging at the selected equalization voltage will continue for this number of hours. F. Equalization Interval - Equalizations are typically done once a month. The cycles are 28 days so the equalization will begin on the same day of the week. Each new cycle will be reset as the equalization starts so that a 28 day period will be maintained. G. Maximum Equalization Cycle - If the battery voltage cannot reach the equalization voltage, the equalization will terminate after this number of hours to avoid over gasing or heating the battery. If the battery requires more time in equalization, the manual push-button can be used to continue for one or more additional equalization cycles Battery Charging References The diversion load battery charging is similar to conventional solar charging. Refer to the following sections in this manual for additional battery charging information. 4.1 Four stages of charging (applies to diversion) 4.3 Temperature Effects and Battery Voltage Sense 4.4 Equalization 4.5 Float 9.0 Battery Information PRUDENCE : La charge de diversion doit être capable d absorber toute la puissance de sortie de la source, mais la charge ne doit jamais dépasser l intensité nominale du contrôleur TriStar, pour ne pas surcharger et endommager la batterie Suitable Loads for Diversion Water heating elements are commonly used for diversion load systems. These heating elements are reliable and widely available. Heating elements are also easy to replace, and the ratings are stable. NOTE: Do not use light bulbs, motors, or other electrical devices for diversion loads. These loads will fail or cause the TriStar to disconnect the load. Only heating elements should be used. REMARQUE : N utilisez pas d ampoules, de moteurs ou d autres appareils électriques pour les charges de diversion. Ces charges ne fonctionneront pas ou provoqueront une déconnexion de la charge par le TriStar. Seuls les éléments de chauffe doivent être utilisés. Water heating elements are typically 120 volts. Elements rated for 12, 24 and 48 volts are also available, but more difficult to source. The de-rating for 120 volt heating elements is discussed in below Definition of Terms Maximum Source Current: This is the maximum current output of all the energy sources (hydro, wind, solar, etc.) added together. This current will be diverted through the TriStar to the diversion load. Maximum Battery Voltage: This maximum voltage is the PWM regulation voltage selected with the switches, plus the increase with an equalization, plus the increase due to lower temperatures. The highest battery voltage is commonly 15, 30 and 60 volts for 12-, 24- and 48-volt systems. Peak Load Current: At the maximum battery voltage, this is the current the diversion load will draw. This peak load current must not exceed the TriStar s rating. 46 DIVERSI CHARGE CTROL 47 MORNINGSTAR CORPORATI 6.0

27 NOTE: Because the battery can supply any size load, the peak load current is not limited by the source (hydro or wind rating). The diversion load s power rating is the critical specification for reliable battery charging. REMARQUE : La batterie pouvant fournir une charge de n importe quelle dimension, le pic d intensité de la charge n est pas limité par la source (puissance hydro ou éolienne). La puissance nominale de la charge de diversion constitue la spécification critique pour une charge fiable de la batterie Load Power Ratings The power rating of the diversion load will depend on the voltage of the battery being charged. If the heating element is not rated for the same voltage as the diversion system, the power rating of the load must be adjusted to the diversion system s voltage. The manufacturers typically rate the heating elements for power at a specified voltage. The peak load current at the load s rated voltage will be the power divided by the rated voltage (I = P / V). For example: 2000W / 120V = 16.7 amps of current. If the load is being used at a voltage less than the load s rated voltage, the power can be calculated by the ratio of the voltages squared. For example, a 120 volt 1000 watt heating element being used at 60 volts: 1000W x (60/120) 2 = 250 watts The 1000W element will only dissipate 250W when being used at 60 volts. NOTE: The loads (heating elements) can be used at the manufacturer s voltage rating, or at a lower voltage. Do not use the load at a higher voltage than the load s rating. REMARQUE : Les charges (éléments de chauffe) peuvent être utilisées à la tension nominale du fabricant ou à une tension inférieure. N utilisez pas la charge à une tension supérieure à la tension nominale Maximum Diversion Load The diversion load should never exceed the TriStar s current rating (45A or 60A). Note that the load is not limited by the source (wind, hydro), and will draw its rated current from the battery. The following table specifies the absolute maximum diversion loads that can be used with each TriStar version. These loads (heating elements) are rated for the same voltage as the system voltage. Nominal Voltage TriStar-45 TriStar-60 48V 2700W at 60V 3600W at 60V 24V 1350W at 30V 1800W at 30V 12V 675W at 15V 900W at 15V These maximum power ratings are translated to the equivalent at 120 volts in the following table. If using heating elements rated for 120 volts, the power ratings of all the elements can be simply added up and the sum compared with this table and no further math is required. Nominal Voltage TriStar-45 TriStar-60 48V 10,800W at 120V 14,400W at 120V 24V 21,600W at 120V 28,800W at 120V 12V 43,200W at 120V 57,600W at 120V To illustrate the same point from the opposite perspective, a heating element rated for 120 volts will draw reduced load current as indicated by the following table. A standard 2,000 watt / 120 Vac heating element is used as the reference. Voltage Power Current 120V 2000 W 16.7 A 60V (48V nominal) 500 W 8.3 A 30V (24V nominal) 125 W 4.2 A 15V (12V nominal) 31 W 2.1 A Whether using dc rated loads (the first table) or 120V elements, the total diversion load current must not exceed the current rating of the TriStar Minimum Diversion Load The diversion load must be large enough to divert all the current produced by the source (wind, hydro, etc.). This value is the maximum battery voltage times the maximum source current. For example, if a hydro source can generate up to 30 amps of current in a nominal 48 volt system (60V maximum), the minimum diversion load size = 60V x 30A = 1,800 watts (for loads rated at 60 volts). General Sizing Example Consider a 24V system with a wind turbine that is rated to generate 35A of current. A TriStar-45 will not provide the 150% diversion load margin, and the TS-45 is only rated for 30A of source current. The TS-45 will not provide enough margin for wind gusts and overloads, so a TS-60/M should be used. The diversion load should be sized for 52.5A (150% of the source current) up to 60A (the rating of the TriStar-60). If 55A is selected for the diversion load, the load must be capable of diverting 55A at 30V (maximum battery voltage). If a 30V heating element is used, it would be rated for 1,650 watts (or from 1,575W to 1,800W per the load range noted above). If a 2,000 watt / 120 volt heating element is used, 13 of these elements in parallel will be required for the diversion load (4.2 amps per element [Table in 6.4.4] x 13 = 54.6 amps). 6.0 continued DIVERSI CHARGE CTROL 49 MORNINGSTAR CORPORATI

28 The minimum diversion load would be the source output (35A) times the voltage (30V). This would require a 1,050 watt heating element rated at 30 volts. Or if a 2,000W heater element rated for 120 volts is used, 9 heater elements will be required to draw the required minimum diversion load at 30 volts. 6.5 NEC Requirements To comply with NEC (B), the following requirements will apply when the TriStar is being used as a diversion charge controller in a photovoltaic system Second Independent Means If the TriStar is the only means of regulating the battery charging in a diversion charging mode, then a second independent means to prevent overcharging the battery must be added to the system. The second means can be another TriStar, or a different means of regulating the charging Percent Rating The current rating of the diversion load must be at least 150% of the TriStar source current rating. Refer to Section 6.2 (Diversion Current Rating). The maximum allowable current ratings for both TriStar versions are summarized below: Max. Input Current Max. Diversion Load Rating TS A 45 A TS-60/M 40 A 60 A CAUTI: The NEC requirement that the diversion load must be sized at least 150% of the controller rating does NOT mean the diversion load can exceed the maximum current rating of the TriStar. NEVER size a diversion load that can draw more than the 45 amps or 60 amps maximum rating of the TriStar controllers. PRUDENCE : L obligation de la CNE indiquant que la charge de diversion doit être 150 % plus grande que la puissance nominale du contrôleur NE signifie PAS que la charge de diversion peut dépasser l intensité maximum du TriStar. Ne dimensionnez JAMAIS une charge de diversion qui peut appeler plus de 45 A ou l intensité maximum de 60 A des contrôleurs TriStar. 7.0 Custom Settings with PC Software An RS-232 connection between the TriStar and an external personal com puter (PC) allows many set-points and operating parameters to be easily adjusted. The adjustments can be simply a small change to one setpoint, or could include extensive changes for a fully customized battery charging or load control program. CAUTI: Only qualified service personnel should change operating parameters with the PC software. There are minimal safeguards to protect from mistakes. Morningstar is not responsible for any damage resulting from custom settings. PRUDENCE : Seul le personnel d entretien qualifié doit modifier les paramètres de fonctionnement avec le logiciel sur ordinateur. Des protections minimales protègent contre les erreurs. Morningstar n est pas responsable des dommages résultants de réglages personnalisés. Consult Morningstar s website for the latest TriStar PC software and instructions. 7.1 Connection to a Computer An RS-232 cable with DB9 connectors (9 pins in 2 rows) will be required. If the computer will be used to change battery charging or load control setpoints, verify that switches 4, 5, 6 are in the custom position (On, On, On) before connecting the TriStar to a computer. The custom position is required to change set-points. See Section Step 3. Disconnect power before changing switches. 7.2 Using the PC Software Download the TriStar PC software from Morningstar s website. Follow the instructions on the website for installing the software on your computer. Open the TriStar PC software. This software will make the connection with the TriStar via the RS-232 cable. The TriStar must be powered by the battery or a power supply to complete the connection. If there is a conflict between the TriStar and PC comm ports, the software will provide instructions to resolve the problem Additional Information Visit Morningstar s website ( for additional diversion charge control information. The website provides expand ed technical support for more complex diversion load systems. 50 DIVERSI CHARGE CTROL 51 MORNINGSTAR CORPORATI

29 7.3 Changing Set-points Follow the instructions in the PC software. CAUTI: There are few limits to the changes that can be made. It is the responsibility of the operator to be certain all changes are appropriate. Any damage resulting to the controller or the system from TriStar setpoint adjustments will not be covered under warranty. PRUDENCE : Les modifications pouvant être effectuées sont sujettes à quelques limites. Il incombe à l opérateur de s assurer que toutes les modifications sont appropriées. Tout dommage au contrôleur ou au système résultant de réglages des points de consigne du TriStar ne sera pas couvert par la garantie. If you are not certain about each of the changes you are making, the software provides for returning to the factory default settings. 7.4 Finish Confirm that the changes made to the TriStar are as you intended. It is advisable to make a record of the changes for future reference. Observe the system behavior and battery charging for a few weeks to verify that the system is operating correctly and as you intended. Exit the software. The PC/TriStar connection can either be disconnected or left in place. 8.0 Self-Test / Diagnostics The TriStar performs a continuous self-test to monitor controller and system operation. Detected problems are classified as either faults or alarms. Typi cally, faults are problems that stop the normal operation of the controller and require immediate attention. Alarms indicate an abnormal condition, but will not stop the controller s operation. If a problem is detected, the TriStar will alert the user to an existing fault or alarm. In this situation, the LED indicators will flash a particular sequence. Section 3.3 references these sequences with their associated faults and alarms. Flashing LED sequences can indicate conditions ranging from a simple battery service reminder to an existing short circuit in the system. It is recommended that the user become familiar with the LED indications and their meanings. If a TriStar meter option has been added, more detailed information concerning faults and alarms will be available. Menus provide text displays of the specific fault as well as indicating on the standard display screens when a problem exists. Consult the meter manual for further details. 8.1 General Troubleshooting TriStar is not powering up Confirm that all circuit breakers and switches in the system are closed Check all fuses Check for loose wiring connections and wiring continuity Verify that the battery voltage is not below 9Vdc (brownout: section 3.4) Verify that the battery power connection is not reversed polarity Flashing/Sequencing LEDs Reference Section 3.3 for a list of LED indications and their corresponding faults/ alarms Self-Test Indication (R - Y - G sequencing) Self-testing will also detect various system wiring faults outside the TriStar Check for both TriStar faults and external system wiring problems The RTS or Battery Sense is not working properly R/Y G/Y sequencing LEDs indicates an RTS or Sense fault Check for a reverse polarity connection on the sense leads Verify that the RTS and Sense connections are wired to the correct terminals Check for shorts and continuity in the cables Verify that good electrical contact is made at the terminals Note that if the TriStar is restarted with an RTS or Sense fault present, it will not detect the RTS or Sense connection and the LED indication will stop CUSTOM SETTINGS WITH PC SOFTWARE 53 MORNINGSTAR CORPORATI

30 8.2 Troubleshooting Solar Charging Over-charging or under-charging the battery switch settings may be wrong RTS is not correcting for high or low temperatures Over-temperature condition is reducing the charging current (heat sink cooling may be blocked indicated with LEDs) Voltage drop between TriStar and battery is too high (connect the battery voltage sense see Section 2.3 Step 5) Battery charging requires temperature compensation (connect a remote temperature sensor) Load is too large and is discharging the battery Not charging the battery switch settings may be wrong (check each switch position carefully) TriStar has detected a fault (indicated by sequencing LEDS, refer to Section 3.3) Solar circuit breaker or disconnect is open Reversed polarity connections at the solar terminals (TriStar will not detect the solar array) Short circuit in the solar array has eliminated part of the array output Solar array is not providing enough current (low sun or fault in the array) Battery is failing and cannot hold a charge 8.3 Troubleshooting Load Control No power to the load switch settings may be wrong (check each switch position carefully) Controller is in LVD (check the LEDs) Load circuit breaker or disconnect may be open Check the load cables for continuity and good connection An over-temperature condition may have caused the load to be disconnected 8.4 Troubleshooting Diversion Control Diversion load is too small so PWM reaches 99% Diversion load is burned out so PWM reaches 99% Diversion load is too large so TriStar faults on overcurrent An overtemperature condition may have caused the load to be disconnected The RTS is not correcting for high or low temperatures Voltage drops between the TriStar and battery are too high Still having problems? Point your web browser to morningstarcorp.com for technical support documents, FAQs, or to request technical support. 9.0 Battery Information The standard battery charging programs in the TriStar controller, as described in Section 4.2, are typical charging algorithms for three battery types: sealed (VRLA) flooded (vented) L-16 group Other battery chemistries such as NiCad, or special voltages such as 36V, can be charged using a custom charging algorithm modified with the PC software. Only the standard TriStar battery charging programs will be discussed here. CAUTI: Never attempt to charge a primary (non-rechargeable) battery. PRUDENCE : N essayez jamais de charger une batterie primaire (non-rechargeable). All charging voltages noted below will be for 12V batteries at 25 C. 9.1 Sealed Batteries The general class of sealed batteries suitable for solar systems are called VRLA (Valve Regulated Lead-Acid) batteries. The two main characteristics of VRLA batteries are electrolyte immobilization and oxygen recombination. As the battery recharges, gasing is limited and is recombined to minimize the loss of water. The two types of VRLA batteries most often used in solar are AGM and Gel. AGM: Absorbed Glass Mat batteries are still considered to be a wet cell because the electrolyte is retained in fiberglass mats between the plates. Some newer AGM battery designs recommend constant voltage charging to 2.45 volts/cell (14.7V). For cycling applications, charging to 14.4V or 14.5V is often recommended. AGM batteries are better suited to low discharge applications than daily cycling. These batteries should not be equalized since gasing can be vented which causes the battery to dry out. There is also a potential for thermal runaway if the battery gets too hot, and this will destroy the battery. AGM batteries are affected by heat, and can lose 50% of their service life for every 8 C (15 F) over 25 C (77 F). It is very important not to exceed the gas recombination capabilities of the AGM. The optimum charging temperature range is from 5 to 35 C (40 to 95 F). Gel: Gel batteries have characteristics similar to AGM, except a silica additive immobilizes the electrolyte to prevent leakage from the case. And like AGM, it SELF-TESTING/DIAGNOSTICS 55 MORNINGSTAR CORPORATI

31 is important to never exceed the manufacturer s maximum charging voltages. Typically, a gel battery is recharged in cycling applications from 14.1V to 14.4V. The gel design is very sensitive to overcharging. For both AGM and Gel batteries, the goal is for 100% recombination of gases so that no water is lost from the battery. True equalizations are never done, but a small boost charge may be needed to balance the individual cell voltages. Other Sealed Batteries: Automotive and maintenance-free batteries are also sealed. However, these are not discussed here because they have very poor lifetimes in solar cycling applications. NOTE: Consult the battery manufacturer for the recommended solar charging settings for the battery being used. REMARQUE : Consultez le fabricant de la batterie quant aux réglages recommandés de charge solaire pour la batterie utilisée. 9.2 Flooded Batteries Flooded (vented) batteries are preferred for larger cycling solar systems. The advantages of flooded batteries include: ability to add water to the cells deep cycle capability vigorous recharging and equalization long operating life In cycling applications, flooded batteries benefit from vigorous charging and equalization cycles with significant gasing. Without this gasing, the heavier electrolyte will sink to the bottom of the cell and lead to stratification. This is especially true with tall cells. Hydrocaps can be used to limit the gasing water loss. Note that a 4% mixture of hydrogen in air is explosive if ignited. Make certain the battery area is well ventilated. Typical equalization voltages for flooded batteries are from 15.3 volts to 16 volts. However, a solar system is limited to what the solar array can provide. If the equalization voltage is too high, the array I-V curve may go over the knee and sharply reduce the charging current. Lead-Calcium: Calcium batteries charge at lower voltages (14.2 to 14.4 typically) and have strong advantages in constant voltage or float applications. Water loss can be only 1/10th of antimony cells. However, calcium plates are not as suitable for cycling applications. Lead-Selenium: These batteries are similar to calcium with low internal losses and very low water consumption throughout their life. Selenium plates also have poor cycling life. Lead-Antimony: Antimony cells are rugged and provide long service life with deep discharge capability. However, these batteries self-discharge much faster and the selfdischarging increases up to five times the initial rate as the battery ages. Charging the antimony battery is typically from 14.4V to 15.0V, with a 120% equalization overcharge. While the water loss is low when the battery is new, it will increase by five times over the life of the battery. There are also combinations of plate chemistries that offer beneficial tradeoffs. For example, low antimony and selenium plates can offer fairly good cycling performance, long life, and reduced watering needs. NOTE: Consult the battery manufacturer for the recommended solar charging settings for the battery being used. REMARQUE : Consultez le fabricant de la batterie quant aux réglages recommandés de charge solaire pour la batterie utilisée. 9.3 L-16 Cells One particular type of flooded battery, the L-16 group, is often used in larger solar systems. The L-16 offers good deep-cycle performance, long life, and low cost. The L-16 battery has some special charging requirements in a solar system. A study found that nearly half of the L-16 battery capacity can be lost if the regulation voltage is too low and the time between finish-charges is too long. One standard charging program in the TriStar is specifically for L-16 batteries, and it provides for higher charging voltages and more frequent equalizations. Additional equalizations can also be done manually with the push-button. A good reference for charging L-16 batteries is a Sandia National Labs report (year 2000) titled PV Hybrid Battery Tests on L-16 Batteries. Website: www. sandia.gov/pv. NOTE: The best charging algorithm for flooded, deep-cycle batteries depends on the normal depth-of-discharge, how often the battery is cycled, and the plate chemistry. Consult the battery manufacturer for the recommended solar charging settings for the battery being used. REMARQUE : Le meilleur algorithme de charge pour les batteries à électrolyte liquide à décharge poussée dépend de l amplitude de la décharge, de la fréquence du cycle de batterie et de la composition chimique des plaques. Consultez le fabricant de la batterie quant aux réglages recommandés de charge solaire pour la batterie utilisée BATTERY INFORMATI 57 MORNINGSTAR CORPORATI

32 10.0 Warranty 11.0 Technical Specifications LIMITED WARRANTY Morningstar TriStar-PWM The TriStar-PWM is warrantied to be free from defects in material and workmanship for a period of FIVE (5) years from the date of shipment to the original end user. Morningstar will, at its option, repair or replace any such defective products. WARRANTY EXCLUSIS AND LIMITATIS: This warranty does not apply under the following conditions: Damage by accident, negligence, abuse or improper use PV or load currents exceeding the ratings of the product Unauthorized product modification or attempted repair Damage occurring during shipment Damage results from acts of nature such as lightning and weather extremes THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHERS, EXPRESS OR IMPLIED. MORNINGSTAR SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATI, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. NO MORNINGSTAR DISTRIBUTOR, AGENT OR EMPLOYEE IS AUTHORIZED TO MAKE ANY MODIFICATI OR EXTENSI TO THIS WARRANTY. MORNINGSTAR IS NOT RESPSIBLE FOR INCIDENTAL OR CSEQUENTIAL DAMAGES OF ANY KIND, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DOWN-TIME, GOODWILL OR DAMAGE TO EQUIPMENT OR PROPERTY. ELECTRICAL System voltage ratings 12, 24, 48 Vdc Current ratings Solar Input TS-45: 45 A TS-60/M: 60 A Current ratings Battery Charge Control TS-45: 45 A TS-60/M: 60 A Current ratings Load Control TS-45: 45 A TS-60/M: 60 A Current ratings Diversion Charge Control TS-45: 45 A diversion load TS-60/M: 60 A diversion load Accuracy 12/24V: 0.1 % ± 50 mv 48V: 0.1 % ± 100 mv Min. voltage to operate 9 V Max. solar array Voc 125 V Max. operating voltage 68 V Self-consumption less than 20 ma High temp shutdown 95ºC disconnect solar 90ºC disconnect load / diversion load 70ºC reconnect solar / load / diversion load Solar high voltage disconnect highest equalization + 0.2V HVD reconnect 13.0V Transient surge protection: 4500 watts Pulse power rating response < 5 nanosec BATTERY CHARGING / RTS Charge algorithm: PMW, constant voltage Temp comp. coefficient 5mV/ºC/cell (25ºC ref) Temp comp. range: 30ºC to +80ºC Temp comp. set-points PWM, float, equalize, HVD (with RTS option) 11.0 R17-8/16 58 WARRANTY INFORMATI 59 MORNINGSTAR CORPORATI

33 BATTERY CHARGING STATUS LEDs G 13.3 to PWM G/Y 13.0 to 13.3 V Y to 13.0 V Y/R 12.0 to V R 0 to 12.0 V Note: Multiply x 2 for 24V systems, x 4 for 48V systems Note: The LED indications are for charging a battery. When discharging, the LEDs will typically be Y/R or R. Appendix 1 Load & Lighting Control Settings The Control Mode/ DC Load Control (1) MECHANICAL Dimensions (mm/inch) Weight (kg/lb) Power terminals: largest wire smallest wire Terminal wire slot Knockout sizes Torque terminals RTS / Sense terminals: wire sizes torque ENVIRMENTAL Operating Altitude Ambient temperature Storage temperature Humidity Enclosure H: mm / inch W: mm / 5.0 inch D: 71.0 mm / 2.8 inch 1.6 kg / 3.5 lb compression connector lug 35 mm 2 / 2 AWG 2.5 mm 2 / 14 AWG 8.2 mm / in wide 9.4 mm / 0.37 in high 1 and 1.25 inch 5.65 Nm / 50 in-lb 1.0 to 0.25 mm 2 / 16 to 24 AWG 0.40 Nm / 3.5 in-lb Below 2000 meters 40 to +45ºC 55 to +85ºC 100% (NC) IP20 Type 1 (indoor & vented), powder coated steel System Voltage (2,3) LVD/LVD R (4,5,6) Not Used (7) Off - Load Control (8) On - Lighting control (8) Figure A1-1 - Step 3. Load / lighting Switch Functions NOTE: The switches should be changed only when there is no power to the controller. Turn off disconnect switches and remove power to the controller before changing a switch. A fault will be indicated if a switch is changed with the controller powered. REMARQUE : Les commutateurs ne doivent être changés que si le contrôleur est hors tension. Mettez les interrupteurs sur arrêt et mettez le contrôleur hors tension avant de changer un commutateur. Une panne sera indiquée en cas de changement d un commutateur quand le contrôleur est sous tension. CAUTI: The TriStar is shipped with all the switches in the position. Each switch position must be confirmed during installation. An incorrect setting could cause damage to the load or other system components. PRUDENCE : Le TriStar est expédié avec tous les interrupteurs en position «ARRÊT». La position de chaque interrupteur doit être confirmée pendant l installation. Un mauvais réglage peut endommager la charge ou d autres composants du système. Appendices 60 TECHNICAL SPECIFICATIS II 61 MORNINGSTAR CORPORATI

34 The switch settings described below are for Load and Lighting Control only. The switches are shipped in the position. The settings will operate as follows: Switch Function 1 Must be for Load, Lighting or Diversion Control 2, 3 Auto voltage select 4, 5, 6 Lowest LVD = 11.1V 7 Diversion Control mode 8 Lighting Control mode To configure your TriStar for the Load Control you require, follow the switch adjustments described below. To change a switch from to, slide the switch up toward the top of the controller. Make sure each switch is fully in the or position. Switch Number 1 - Control Mode: Load & Lighting Control Mode Switch 1 Charging Off Load/Lighting On The switch selectable voltages are for 12V, 24V or 48V lead-acid batteries. Although the auto voltage selection is very dependable, it is recommended to use the switches to secure the correct system voltage. Switches Number 4,5,6 - Load Control Algorithm: For normal Load Control Mode, set the switches 4,5,&6 according to the table below. For Lighting Control, see the table and Figure 2.4 on the next page. LVD Switch 4 Switch 5 Switch Off Off Off 11.3 Off Off On 11.5 Off On Off 11.7 Off On On 11.9 On Off Off 12.1 On Off On 12.3 On On Off Custom On On On Figure A1-2 - Step 3 Switch #1 For Load or Lighting Control mode, move the switch to the position as shown. Switches Number 2,3 - System Voltage: Voltage Switch 2 Switch 3 Auto Off Off 12 Off On 24 On Off 48 On On Auto Select 24 Volts LVD 11.1V LVD 11.9V LVD 11.3V LVD 12.1V LVD 11.5V LVD 12.3V LVD 11.7V Custom Figure A1-4 - Step 3 Switch # 4,5,6 12 Volts Figure A1-3 - Step 3 Switches # 2,3 48 Volts Select one of the 7 standard load control algorithms, or select the custom switch for special custom settings using the PC software. Refer to Section 5.1 for the 7 standard LVD settings, LVD R reconnect settings, and current compensation values. The auto voltage selection occurs when the battery is connected and the TriStar starts up. There should be no loads on the battery that might cause a discharged battery to indicate a lower system voltage. Appendices 62 APPENDICES 63 MORNINGSTAR CORPORATI

35 Switches Number 4,5,6 - Lighting Control Algorithm: For Lighting Control mode, set the switches 4,5,& 6 according to the table below. hrs hrs after before Sunset Sunrise Switch 4 Switch 5 Switch Off Off Off 8 0 Off Off On 10 0 Off On Off 3 1 Off On On 4 2 On Off Off 6 2 On Off On Dusk to Dawn On On Off Custom On On On 4 hours 6 hours after sunset after sunset, 2 hours before sunrise 8 hours after sunset 10 hours after sunset 6 hours after sunset, 2 hours before sunrise Dusk to Dawn Switch Number 7 - Must be : Switch 7 Off Figure A1-6 - Step 3 Switch # 7 In Load Control and Lighting modes, switch #7 must be in the position. Switch Number 8 - Lighting Control: Control Switch 8 Lighting Disabled Off Lighting Enabled On Lighting Figure A1-7 - Step 3 Switch # 8 Lighting To enable lighting control, switch #8 must be in the position. NOTE: Confirm all dip-switch settings before going to the next installation steps. 3 hours after sunset, 1 hour before sunrise Custom Settings REMARQUE : Confirmez les réglages de tous les commutateurs dip avant de passer aux étapes suivantes d installation. Figure A1-5 - Step 3 Switch # 4,5,6 Select one of the 7 standard Lighting Control algorithms, or select the custom switch for special custom settings using the PC software. The default LVD and LVD reconnect settings for Lighting Control are listed below. These values can be changed in custom settings. LVD LVDR Volts Volts Appendices 64 APPENDICES 65 MORNINGSTAR CORPORATI

36 Appendix 2 - Diversion Charge Control Switch Settings The Diversion Charge Control function adjustments: Control Mode/ Load (1) System Voltage (2,3) Diversion Charge Algorithm (4,5,6) Select Diversion Mode (7) Battery Equalization (8) Figure A2-1 - Step 3 (Diversion) Switch Functions As shown in the diagram, all the positions are in the position except switches 1 and 7, which are. NOTE: The switches should be changed only when there is no power to the controller. Turn off disconnect switches and remove all power to the controller before changing a switch. A fault will be indicated if a switch is changed with the controller powered. REMARQUE : Les commutateurs ne doivent être changés que si le contrôleur est hors tension. Mettez les interrupteurs sur arrêt et mettez le contrôleur hors tension avant de changer un commutateur. Une panne sera indiquée en cas de changement d un commutateur quand le contrôleur est sous tension. the position, Diversion Charge Contol is set. The settings will operate as follows: Switch Function 1 Must be to set Diversion Control 2, 3 Auto voltage selected 4, 5, 6 Lowest battery charging voltage 7 Must be to set Diversion Control 8 Manual Equalization To configure your TriStar for the diversion battery charging and control you require, follow the switch adjustments described below. To change a switch from to, slide the switch up toward the top of the controller. Make sure each switch is fully in the or position. Switch Number 1 - Control Mode: Solar Battery Charging Control Switch 1 Charging Off Load On Figure A2-2 - Step 3 Switch #1 For the Diversion Charge Control mode, move the switch to the position as shown. Switches Number 2,3 - System Voltage: Voltage Switch 2 Switch 3 Auto Off Off 12 Off On 24 On Off 48 On On Auto Select 24 Volts CAUTI: The TriStar is shipped with all the switches in the position. Each switch position must be confirmed during installation. A wrong setting could cause damage to the battery or other system components. PRUDENCE : Le TriStar est expédié avec tous les interrupteurs en position «ARRÊT». La position de chaque interrupteur doit être confirmée pendant l installation. Un mauvais réglage peut endommager la charge ou d autres composants du système. The switch settings described below are Diversion Charge Control only. The switches are shipped in the position. With switches 1 and 7 in 12 Volts Figure A2-3 - Step 3 Switches # 2,3 48 Volts The auto voltage selection occurs when the battery is connected and the TriStar starts-up. There should be no loads on the battery that might cause a discharged battery to indicate a lower system voltage. The switch default voltages are for 12V, 24V or 48V lead-acid batteries. Although the auto voltage selection is very dependable, it is recommended to use the switches to secure the correct system voltage. Appendices 66 APPENDICES 67 MORNINGSTAR CORPORATI

37 Switches Number 4,5,6 - Diversion Charge Control: Battery Type PWM Switch 4 Switch 5 Switch Off Off Off Off Off On Off On Off Off On On On Off Off On Off On On On Off 8 Custom On On On Switch Number 8 - Battery Equalization: Equalize Switch 8 Manual Off Auto On Manual DIV 13.8V DIV 14.6V Automatic Figure A2-6 - Step 3 Switch # 8 DIV 14.0V DIV 14.2V DIV 14.4V DIV 14.8V DIV 15.0V Custom Figure A2-4 - Step 3 Switches # 4,5,6 Select one of the 7 standard diversion charging algorithms, or select the custom switch for special custom settings using the PC software. Refer to Section 6.3 for information describing the 7 standard diversion charging algorithms. Refer to Section 9.0 of this manual for battery charging information. In the Auto Equalization mode (switch 8 On), battery equalization will automatically start and stop according to the battery program selected by the switches 4,5,6 above. See Section 6.0 for detailed information about each standard diversion battery charging algorithm and equalization. In the Manual Equalization mode (switch # Off), equalization will occur only when manually started with the push-button. Automatic starting of equalization is disabled. The equalization will automatically stop per the battery algorithm selection. In both cases (auto and manual mode), the push-button can be used to start and stop battery equalization. NOTE: Confirm all dip-switch settings before going to the next installation steps. REMARQUE : Confirmez les réglages de tous les commutateurs dip avant de passer aux étapes suivantes d installation. Switch Number 7 - Select Diversion: Switch 7 On Figure A2-5 - Step 3 Switch # 7 In the Diversion Charge Control mode, switch 7 must be in the position. Appendices 68 APPENDICES 69 MORNINGSTAR CORPORATI

38 Appendix 3 - LED Indications LED Display Explanation: G = green LED is lit Y = yellow LED is lit R = red LED is lit G/Y = Green and Yellow are both lit at the same time G/Y - R = Green & Yellow both lit, then Red is lit alone Sequencing (faults) has the LED pattern repeating until the fault is cleared 1. General Transitions: Controller start-up G - Y - R (one cycle) Push-button equalize start G/Y/R - G/Y/R - G (one cycle) Push-button equalize stop G/Y/R - G/Y/R - R (one cycle) Battery service is required all 3 LEDs blinking until service is reset 2. Battery Status General state-of-charge see battery SOC indications below PWM absorption G blinking (1/2 second on / 1/2 second off) Equalization state G fast blink (2 to 3 times per second) Float state G slow blink (1 second on / 1 second off) Battery State-of-Charge LED Indications (when battery is charging): G on 80% to 95% SOC G/Y on 60% to 80% SOC Y on 35% to 60% SOC Y/R on 0% to 35% SOC R on battery is discharging 3. Faults & Alarms Short circuit - solar/load Overload - solar/load Over-temperature High voltage disconnect Reverse polarity - battery Reverse polarity - solar switch fault Self-test faults Temperature probe (RTS) Battery voltage sense R/G - Y sequencing R/Y - G sequencing R - Y sequencing R - G sequencing no LEDs are lighted No fault indication R - Y - G sequencing R - Y - G sequencing R/Y - G/Y sequencing R/Y - G/Y sequencing LOAD CTROL 2. Load Status G G/Y Y Y/R R-Blinking R-LVD 12V 24V 48V LVD+ 0.60V 1.20V 2.40V LVD+ 0.45V 0.90V 1.80V LVD+ 0.30V 0.60V 1.20V LVD+ 0.15V 0.30V 0.60V LVD The load status LEDs are determined by the LVD voltage plus the specified transition voltages. As the battery voltage rises or falls, each voltage transition will cause a change in the LEDs. Appendices 70 APPENDICES 71 MORNINGSTAR CORPORATI

39 12.0 Certifications TUVRheinland CERTIFIED ALL COMPENTS REACH COMPLIANT Registration, Evaluation and Authorization of Chemicals THIS PAGE IS LEFT BLANK INTENTIALLY Complies with ETL UL 1741 and cetl CSA-C22.2 No Complies with TUV IEC Complies with the US National Electrical Code Complies with the Canadian Electrical Code FCC Class B compliant ENs Directives: Complies with ENs and LVD standards for CE marking Immunity: EN : 2006 EN : 2009 Emissions: CISPR 22: 2008 Safety: EN , EN (battery chargers) EN : 2010 TrisStar TM, MeterBus TM are trademarks of Morningstar Corporation MODBUS TM and MODBUS TCP/IP TM are trademarks of Modbus IDA Morningstar Corporation. All rights reserved. MS v CERTIFICATIS

Installation and Operation Manual

Installation and Operation Manual Solar System Controller Installation and Operation Manual... Solar Battery Charging... Load Control... Diversion Charge Control email: info@morningstarcorp.com www.morningstarcorp.com Table of Contents

More information

SUNSAVER MPPT TM. Installation, Operation and Maintenance Manual. For the most recent manual revisions, see the version at:

SUNSAVER MPPT TM. Installation, Operation and Maintenance Manual. For the most recent manual revisions, see the version at: SUNSAVER MPPT TM WITH TRAKSTAR TM MPPT TECHNOLOGY Installation, Operation and Maintenance Manual For the most recent manual revisions, see the version at: www.morningstarcorp.com MAXIMUM POWER POINT TRACKING

More information

SUNSAVER MPPT TM. Installation, Operation and Maintenance Manual. For the most recent manual revisions, see the version at:

SUNSAVER MPPT TM. Installation, Operation and Maintenance Manual. For the most recent manual revisions, see the version at: SUNSAVER MPPT TM WITH TRAKSTAR TM MPPT TECHNOLOGY Installation, Operation and Maintenance Manual For the most recent manual revisions, see the version at: www.morningstarcorp.com MAXIMUM POWER POINT TRACKING

More information

ProStar MPPT TM. Solar Charging System Controller. Installation, Operation and Maintenance Manual

ProStar MPPT TM. Solar Charging System Controller. Installation, Operation and Maintenance Manual ProStar MPPT TM Solar Charging System Controller Installation, Operation and Maintenance Manual For the most recent manual revisions, see the e-version at: www.morningstarcorp.com www.morningstarcorp.com

More information

ProStar MPPT TM. Solar Charging System Controller. Installation, Operation and Maintenance Manual

ProStar MPPT TM. Solar Charging System Controller. Installation, Operation and Maintenance Manual ProStar MPPT TM Solar Charging System Controller Installation, Operation and Maintenance Manual For the most recent manual revisions, see the version at: www.morningstarcorp.com www.morningstarcorp.com

More information

ProStar MPPT TM. Solar Charging System Controller. Installation, Operation and Maintenance Manual

ProStar MPPT TM. Solar Charging System Controller. Installation, Operation and Maintenance Manual ProStar MPPT TM Solar Charging System Controller Installation, Operation and Maintenance Manual For the most recent manual revisions, see the version at: www.morningstarcorp.com www.morningstarcorp.com

More information

Solar Charging System Controller. Installation, Operation and Maintenance Manual. Solar Battery Charger

Solar Charging System Controller. Installation, Operation and Maintenance Manual.  Solar Battery Charger TRISTAR MPPT TM Solar Charging System Controller Installation, Operation and Maintenance Manual For the most recent manual revisions, see the version at: www.morningstarcorp.com Solar Battery Charger With

More information

Solar - Wind Charging System Controller. Installation and Operation Manual

Solar - Wind Charging System Controller. Installation and Operation Manual TRISTAR MPPT 600V TM Solar - Wind Charging System Controller Installation and Operation Manual Solar-Wind Battery Charger With TrakStar TM Maximum Power Point Tracking Technology www.morningstarcorp.com

More information

WITH TRAKSTAR TM MPPT TECHNOLOGY. Installation and Operation Manual. Model: SS-MPPT-15L

WITH TRAKSTAR TM MPPT TECHNOLOGY. Installation and Operation Manual. Model: SS-MPPT-15L SUNSAVER MPPT TM WITH TRAKSTAR TM MPPT TECHNOLOGY Installation and Operation Manual Model: SS-MPPT-15L 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com SunSaver MPPT

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: ZR-RK Series LED Retrofit Troffer Kit Includes: ZR22RK and ZR24RK Standard and Emergency Luminaires IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed

More information

PV SYSTEM CONTROLLERS. Installation and Operation Manual. SunSaver Models Included in this Manual:

PV SYSTEM CONTROLLERS. Installation and Operation Manual. SunSaver Models Included in this Manual: SUNSAVER PV SYSTEM CONTROLLERS Installation and Operation Manual SunSaver Models Included in this Manual: SS-6-12V / SS-6L-12V SS-10-12V SS-10L-12V / SS-10L-24V SS-20L-12V / SS-20L-24V 8 Pheasant Run Newtown,

More information

Parent s Guide. This guide contains important information. Please keep it for future reference US

Parent s Guide. This guide contains important information. Please keep it for future reference US Parent s Guide This guide contains important information. Please keep it for future reference. 91-003324-000 US INTRODUCTION The Stack & Tumble Elephant TM provides a silly twist on the classic ring stacker.

More information

Solar System Controller. Installation and Operation Manual. Solar Battery Charger

Solar System Controller. Installation and Operation Manual. Solar Battery Charger TRISTAR MPPT TM Solar System Controller Installation and Operation Manual Solar Battery Charger with TrakStar TM Maximum Power Point Tracking Technology MAXIMUM POWER POINT TRACKING 8 Pheasant Run Newtown,

More information

GVB-8 (Boost) Manual

GVB-8 (Boost) Manual GVB-8 (Boost) Manual Solar Charge Controllers with Maximum Power Point Tracking For models: GVB-8-Pb-12V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded GVB-8-Pb-24V: GVB-8-Pb-36V: GVB-8-Pb-48V: GVB-8-Pb-CV: 24V

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide Current Revision: June 2009 Table of Contents PAGE IMPORTANT NOTES ------------------------------------------------------------------- 3 20T Main Electrical System --------------------------------------------------------------

More information

www.fisher-price.com P6246 R2772 P6248 P6247 Each sold separately and subject to availability. Vehicles shown in illustrations may be different than the vehicle included with your toy. 1 Battery Installation

More information

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY SMT WITH MPPT TECHNOLOGY Installation and Operation Manual Model:SMT SMT Dimensions Specification Summary System Voltage 12 V/24V Rated Battery Current 12V, 5A 8A 10A 15A 20A 25A 24V, 5A 8A 10A 15A Rated

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION UR Series LED Upgrade Kit Includes: 24" Linear Option IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL

More information

GV-10 Manual 10.5A / 140W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking

GV-10 Manual 10.5A / 140W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking GV-10 Manual Solar Charge Controllers with Maximum Power Point Tracking For models: GV-10-Pb-12V: GV-10-Pb-CV: 12V Lead-Acid/AGM/Gel/Sealed/Flooded 12V Custom Multi-Stage Lead-Acid/AGM/Gel/ Sealed/Flooded

More information

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V PHOTOVOLTAIC SYSTEM CONTROLLERS OPERATOR S MANUAL SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V 6A / 12V 10A / 12V 10A / 24V 20A / 12V 20A

More information

Palomino BATTERY CHARGERS. Installation and Operating Instructions. One Technology Place Caledonia, New York The Power of Excellence

Palomino BATTERY CHARGERS. Installation and Operating Instructions. One Technology Place Caledonia, New York The Power of Excellence Palomino BATTERY CHARGERS Installation and Operating Instructions One Technology Place Caledonia, New York 14423 The Power of Excellence FM1320 REV - B IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS IMPORTANTES

More information

ProStar TM. Solar Charging System Controller Installation, Operation, and Maintenance Manual. Languages: English, French, German, Spanish

ProStar TM. Solar Charging System Controller Installation, Operation, and Maintenance Manual. Languages: English, French, German, Spanish ProStar TM Solar Charging System Controller Installation, Operation, and Maintenance Manual Languages: English, French, German, Spanish For the most recent manual revisions, see the version at: www.morningstarcorp.com

More information

P

P P7639 Please keep this instruction sheet for future reference, as it contains important information. Requires four AA batteries (included) for operation. Adult assembly is required. Tool required for assembly:

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Solar Charge Controller Quick Guide 200W 300W 400W 600W 850W V. 2.2 1. Introduction solar charge controller uses PWM-based DSP controller to keep the batteries regulated and prevent batteries from overcharging

More information

The Traveler Series: Adventurer

The Traveler Series: Adventurer The Traveler Series: Adventurer RENOGY 30A Flush Mount Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.2 Important Safety Instructions Please save these instructions.

More information

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit TRMUNV065ECxyyZ TRAUNV065ECxyyZ Installation Instructions subject to change without notice. Page 1 of 8 1.0 INSTALLATION WARNINGS 1. 2. 3. 4. 5. 6. "THIS

More information

Letter Band Phonics Jam

Letter Band Phonics Jam Letter Band Phonics Jam TM Parent s Guide This guide contains important information. Please keep it for future reference. 91-003480-005 US INTRODUCTION Thank you for purchasing the Letter Band Phonics

More information

Duo Battery Charge Controller

Duo Battery Charge Controller Duo Battery Charge Controller RENOGY 10A 20A Pulse Width Modulation Solar Charge Controller Manual 1 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678 Version: 1.2 Important Safety Instructions

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Battery 12V battery system 24V battery system Type Type Code Bulk Floating Bulk Floating Vented 01 14.3 V 13.2 V 28.6 V 26.4 V Sealed 02 14.3 V

More information

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F SAFETY S IMPORTANT SAFETY INFORMATION SUITABLE FOR DRY OR DAMP LOCATIONS. NOT FOR USE WITH PHASE CUT DIMMERS. Risk of shock. Disconnect power before installation. DANGER CONVIENT AUX EMPLACEMENTS HUMIDES.

More information

GVB-8 (Boost) Manual

GVB-8 (Boost) Manual www.genasun.com GVB-8 (Boost) Manual Solar Charge Controllers with Maximum Power Point Tracking For models: GVB-8-Pb-12V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded GVB-8-Pb-24V: 24V Lead-Acid/AGM/Gel/Sealed/Flooded

More information

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame Installation Guide Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF ELECTRIC SHOCK Turn power off before

More information

GVB-8 (Boost) Manual

GVB-8 (Boost) Manual GVB-8 (Boost) Manual Solar Charge Controllers with Maximum Power Point Tracking For models: GVB-8-Pb-12V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded GVB-8-Pb-24V: GVB-8-Pb-36V: GVB-8-Pb-48V: GVB-8-Pb-CV: 24V

More information

ProStar TM. Solar Charging System Controller Installation, Operation, and Maintenance Manual

ProStar TM. Solar Charging System Controller Installation, Operation, and Maintenance Manual ProStar TM Solar Charging System Controller Installation, Operation, and Maintenance Manual For the most recent manual revisions, see the version at: www.morningstarcorp.com www.morningstarcorp.com MODELS

More information

Solar Charge Controller

Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Type Battery Type Code SC-600W MPPT Bulk Voltage Floating Voltage Vented 01 28.6 V 26.4 V Sealed 02 28.6 V 26.8 V Gel 03 28.6 V 27.4 V NiCd 04 28.6

More information

The Traveler Series: Wanderer

The Traveler Series: Wanderer The Traveler Series: Wanderer RENOGY 30A PWM Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version: 2.3 Important Safety Instructions Please save these instructions.

More information

The Traveler Series TM : Adventurer

The Traveler Series TM : Adventurer The Traveler Series TM : Adventurer 30A PWM Flush Mount Charge Controller w/ LCD Display 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 3.4 Important Safety Instructions Please save

More information

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.

More information

Press the buttons for fun sounds and music! fisher-price.com

Press the buttons for fun sounds and music! fisher-price.com K7189 Press the buttons for fun sounds and music! fisher-price.com Please keep these instructions for future reference, as they contain important information. Requires three button cell (LR44) batteries

More information

Powerware Vdc Extended Battery Cabinet User s Guide.

Powerware Vdc Extended Battery Cabinet User s Guide. Powerware 9125 48 Vdc Extended Battery Cabinet User s Guide www.powerware.com FCC Part 15 Class A EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class A digital

More information

Specification Grade Contemporary Wall Mount/Technical Installation Data

Specification Grade Contemporary Wall Mount/Technical Installation Data AVAILABLE CONFIGURATIONS RECESSED MOUNT SURFACE MOUNT MOUNTING REQUIREMENTS A. Recessed Mount: Minimum 4-Gang Box, 1-5/8 in. Deep (72.8 Cubic Inches) with 4-Gang Box Cover (20.3 Cubic Inches) B. Surface

More information

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries 8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A Charges & Maintains Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries USER S MANUAL 5 User s Manual And Guide To Professional Battery Charging

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 4: Alarm point for low battery voltage table Model Alarm point SCC-MPPT-300 10.5 V SCC-MPPT-600 21.0 V Table 5: Charging hour table for reference Battery Capacity To 90% capacity @ 25A charging current

More information

UB-2 2 Universal Button

UB-2 2 Universal Button UB-2 2 Universal Button UB-2/LTUL Universal Button with Latching Timer ADA Compliant For UB-2/LTUL the enclosed timer is to be used and installed per the enclosed LT-1UL installation sheet. For access

More information

The Traveler Series: Wanderer

The Traveler Series: Wanderer The Traveler Series: Wanderer RENOGY 30A Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.0 Important Safety Instructions Please save these instructions. This

More information

X0056. fisher-price.com

X0056. fisher-price.com X0056 Please keep this instruction sheet for future reference, as it contains important information. Adult assembly is required. Requires three button cell (LR44) alkaline batteries (included). Batteries

More information

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité ! Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité Manual for the following Battery Fuel Gauge models: BFGOV12V, BFGOV24V, BFGOV36V, BFGOV48V, BFGOV64V and

More information

Y9854. fisher-price.com

Y9854. fisher-price.com Y9854 Please keep this instruction sheet for future reference, as it contains important information. Requires two AA (LR6) alkaline batteries for operation (not included). Adult assembly is required. Tool

More information

Captivate Illuminated Mirror Light

Captivate Illuminated Mirror Light ENGLISH WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY FRANÇAIS MISES EN GARDE ET SÉCURITÉ: SE IL VOUS PLAÎT LIRE ATTENTIVEMENT WARNING: RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRE WIRING AND ELECTRICAL

More information

Cable Cubby 1202 and 1402 Installation Guide

Cable Cubby 1202 and 1402 Installation Guide Cable Cubby 0 and 40 Installation Guide IMPORTANT: Go to www.extron.com for the complete user guide, installation instructions, and specifications. This guide provides instructions for an experienced technician

More information

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité Manual for the Following Battery Discharger: BD6812QUAD 022118-70329 IMPORTANT NOTICE: Please save and read

More information

RAPID SHUTDOWN COMBINER

RAPID SHUTDOWN COMBINER RAPID SHUTDOWN COMBINER Installation and Operation Guide Revision B 2017, Yaskawa Solectria Solar IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 1. General Safety Information This manual contains

More information

GP-PWM-30-UL. User Manual GoPower!

GP-PWM-30-UL. User Manual GoPower! User Manual Contents 1.0 Installation Overview 4 1.1 Introduction 4 1.2 System Voltage and Current 4 1.3 Battery Type 4 1.4 Low Voltage Disconnect Function (USB Port) 5 1.5 Regulatory Information 5 1.6

More information

XM Series. Quick Start Guide. Technology at Work XMCom9

XM Series. Quick Start Guide. Technology at Work XMCom9 XM Series Quick Start Guide Technology at Work. 062411XMCom9 Copyright 2011 Janam Technologies LLC. All rights reserved. XM Series, Janam and the Janam logo are trademarks of Janam Technologies LLC. Other

More information

MNBE-8D2x2 INSTRUCTIONS

MNBE-8D2x2 INSTRUCTIONS MNBE-8D2x2 INSTRUCTIONS MNBE-8D2x2 OUTDOOR 3R ENCLOSURE MNBE-8D2x2 Battery Enclosure with locking door and one shelf. Outdoor 3R rain type design. Powder coated aluminum and stainless steel construction.

More information

Cruising Charger Series OWNER S MANUAL

Cruising Charger Series OWNER S MANUAL R Cruising Charger Series OWNER S MANUAL ON BOARD BATTERY CHARGERS Models DC Amperage No. Of Banks Volts 2614A 5,10 Amps 2 Bank 12/12 2614A-230 2621A 5,5,10 Amps 3 Banks 12/12/12 2621A-230 2622A 10,10

More information

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3) A. CHECKLIST (4 each AA Batteries Included) FOR DOOR AND FRAME PREPARATION INSTRUCTIONS, SEE APPENDIX A OR GO TO PROXESS.COM Parts List: Each Proxess C-Series lockset includes Exterior lock assembly (include

More information

Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included).

Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included). Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included). Adult assembly is required. Tool required for battery

More information

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité Manual for the Following Battery Charger Models i2412, i3612, i4809, i2425, i3625, and i4818 081808 IMPORTANT

More information

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V SOLAR LIGHTING CONTROLLER OPERATOR S MANUAL SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V 10A / 12V 10A / 24V 20A / 12V 20A / 24V 1098 Washington Crossing Road Washington Crossing,

More information

V9961 V9961

V9961 V9961 V9961 www.fisher-price.com Please keep this instruction sheet for future reference, as it contains important information. Adult assembly required. Requires one "AAA" battery (included). Tool required for

More information

MOONRING 1.5 MOONRING 3

MOONRING 1.5 MOONRING 3 INSTALLATION INSTRUCTIONS MOONRING 1.5 MOONRING 3 MR1.5 & MR3 Suspended, Ceiling LED n A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings!

More information

CSD Series Current Devices Split Core

CSD Series Current Devices Split Core CSD Series Current Devices Split Core Installation Instructions CSD-CF0A0-1 CSD-CF0J0-1 CSD-CA1G0-1 Part. 24-10345-34, Rev. D Issued March 31, 2014 Supersedes April 5, 2013 Applications The Current Switch

More information

2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY / ANT-2WDSS. User Guide For Key

2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY / ANT-2WDSS. User Guide For Key 2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY / ANT-2WDSS User Guide For Key This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled

More information

EcoBoost MPPT TM. Solar Charging System Controller. Installation, Operation and Maintenance Manual

EcoBoost MPPT TM. Solar Charging System Controller. Installation, Operation and Maintenance Manual EcoBoost MPPT TM Solar Charging System Controller Installation, Operation and Maintenance Manual For the most recent manual revisions, see the version at: www.morningstarcorp.com www.morningstarcorp.com

More information

LED DayLite WireLess Mini

LED DayLite WireLess Mini LED DayLite WireLess Mini User Guide Ver. 10.17 Contents Indications for Use... 3 Device Description... 3 Device Diagrams... 4 Directions for Use... 6 Charging the Batteries... 6 Using the Headlight...

More information

W1392. fisher-price.com

W1392. fisher-price.com W1392 Please keep this instruction sheet for future reference, as it contains important information. Requires three C batteries (LR14) alkaline batteries (not included) for operation. Adult assembly is

More information

W9740. fisher-price.com. 2 Ride. 1 Sit. 3 Walk

W9740. fisher-price.com. 2 Ride. 1 Sit. 3 Walk W9740 2 Ride 1 Sit 3 Walk Please keep this instruction sheet for future reference, as it contains important information. For ages 9 36 months and up to 44 lbs (20 kg). Adult supervision is required. Never

More information

Certification Exhibit FCC ID: SK9OW1 IC: 864G-OW1. FCC Rule Part: IC Radio Standards Specification: RSS-247. ACS Project Number:

Certification Exhibit FCC ID: SK9OW1 IC: 864G-OW1. FCC Rule Part: IC Radio Standards Specification: RSS-247. ACS Project Number: Certification Exhibit FCC ID: SK9OW1 IC: 864G-OW1 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-247 ACS Project Number: 16-0295 Manufacturer: Itron, Inc. Model: OW1 Manual 5015 B.U. Bowman

More information

GP-PWM-30-SB. User Manual 30 AMP PWM SOLAR CONTROLLER Go Power!

GP-PWM-30-SB. User Manual 30 AMP PWM SOLAR CONTROLLER Go Power! GP-PWM-30-SB User Manual 30 AMP PWM SOLAR CONTROLLER Contents 1.0 Installation Overview 3 1.1 Introduction 3 1.2 System Voltage and Current 3 1.3 Battery Type 3 1.4 Low Voltage Disconnect Function (USB

More information

W9740. Ride. Sit. Walk. fisher-price.com

W9740. Ride. Sit. Walk. fisher-price.com W9740 Ride Sit Walk Please keep this instruction sheet for future reference, as it contains important information. For ages 9 36 months and up to 44 lbs (20 kg). Adult supervision is required. Never use

More information

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité Manual for the Following Battery Charger Models: 1250OB, 2440OB, 2450OB and 4836OB 030713 IMPORTANT NOTICE:

More information

Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries (included) for operation. Adult assembly is required. Tool required for battery

More information

Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord

Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System Designed for Six-cell and three-cell Flooded/AGM/GEL Lead-Acid Batteries and Four-Cell Lithium Iron Phosphate (LiFePO4) Batteries

More information

BFK51 CFD40 CHM41. fisher-price.com

BFK51 CFD40 CHM41. fisher-price.com BFK51 CFD40 CHM41 Please keep this instruction sheet for future reference, as it contains important information. Requires three AA (LR6) alkaline batteries (not included). Adult assembly is required. Tool

More information

Solar System Controller. Installation and Operation Manual. Solar Battery Charger with TrakStar TM Maximum Power Point Tracking Technology

Solar System Controller. Installation and Operation Manual. Solar Battery Charger with TrakStar TM Maximum Power Point Tracking Technology TRISTAR MPPT TM Solar System Controller Installation and Operation Manual Solar Battery Charger with TrakStar TM Maximum Power Point Tracking Technology MAXIMUM POWER POINT TRACKING 8 Pheasant Run Newtown,

More information

- Wiring Brochure Zone Manager 335

- Wiring Brochure Zone Manager 335 - Wiring Brochure W 335 12/08 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications Rough-in Wiring Rough-in wiring instructions 3 4 Wiring

More information

Cable Cubby 650 UT Installation Guide

Cable Cubby 650 UT Installation Guide e NT: RTA.com for thtion O P IM tron talla w.ex uide, ins ations. o ww Go t te user g specific nd ple com ctions, a u instr Cable Cubby 650 UT Installation Guide This guide provides instructions for an

More information

W3599

W3599 www.fisher-price.com W3599 Please keep this instruction sheet for future reference, as it contains important information. Requires two "AAA" batteries (included) for vehicles. Requires six "AAA" (LR03)

More information

X2916. fisher-price.com WARNING. Overhead Gym. Tummy Time Fun

X2916. fisher-price.com WARNING. Overhead Gym. Tummy Time Fun X2916 Overhead Gym Tummy Time Fun WARNING To prevent entanglement injury, never place gym in a crib or playpen. Never add strings, ties or other products to the gym. Please keep this instruction sheet

More information

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series) GE Lighting Installation Guide Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series) Features UL 1598 Suitable for Wet Locations IP66 Rated Ingress Protection BEFORE YOU BEGIN Read these

More information

W

W W0275 Actual product may vary from the photos. Please keep this instruction sheet for future reference, as it contains important information. Requires four "AA" (LR6) alkaline batteries (not included)

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 6400 Vehicle Dock INSTALLATION INSTRUCTIONS " " " " " " " " " " " " " " " " " " " " " " " " " " " " PN: 962-020-006 Revision B August 1998 " NOTICE The information contained herein is proprietary and is

More information

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Lumination TM LED Luminaires LAL Series - Continuous Run Option GE Lighting Installation Guide Lumination TM LED Luminaires LAL Series - Continuous Run Option BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF ELECTRIC

More information

T

T T4262 Please keep this instruction sheet for future reference, as it contains important information. Maximum weight: 44 lbs. (20 kg). For ages between 9 months and 3 years. Requires three AA batteries

More information

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa. Oakland, INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5 LP3.5 Suspended LED A 1035 22nd Avenue, Unit 1 n CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com Safety & Warnings! 1. Read all instructions.

More information

OPTI-Solar PWM SERIES

OPTI-Solar PWM SERIES OPTI-Solar PWM SERIES SOLAR CHARGE CONTROLLER SC-45/ SC-60 Installation and Operation Manual USER MANUAL Solar Battery Charging Load Control Diversion Charge Control CONTENTS Specifications...I Chapter

More information

Tracer- BN Series. MPPT Solar Charge Controller. User Manual. Models: Tracer1215BN/Tracer2215BN Tracer3215BN/Tracer4215BN

Tracer- BN Series. MPPT Solar Charge Controller. User Manual. Models: Tracer1215BN/Tracer2215BN Tracer3215BN/Tracer4215BN Tracer- BN Series MPPT Solar Charge Controller User Manual Models: Tracer1215BN/Tracer2215BN Tracer3215BN/Tracer4215BN Important Safety Instructions Please reserve this manual for future review. This

More information

Tractor Interface Module Installation Instructions. Switch Input (TIM-SI)

Tractor Interface Module Installation Instructions. Switch Input (TIM-SI) Tractor Interface Module Installation Instructions Switch Input (TIM-SI) 821-7002 Installation Instructions Tractor Interface Module Switch Input (TIM-SI) 821-7002 Getting Started... 1 Installing the TIM...

More information

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité Manual for the Following Battery Charger Models: 1212, 1212OB, 1225, 1225OB, 2412, 2412OB, 2420, 2420OB,

More information

R

R R3858 Please keep this instruction sheet for future reference, as it contains important information. Adult assembly is required. Tools required for assembly: Phillips Screwdriver, Hammer and Scrap Block

More information

WITH TRAKSTAR TM MPPT TECHNOLOGY. Installation and Operation Manual. Model: SS-MPPT-15L

WITH TRAKSTAR TM MPPT TECHNOLOGY. Installation and Operation Manual. Model: SS-MPPT-15L SUNSAVER MPPT TM WITH TRAKSTAR TM MPPT TECHNOLOGY Installation and Operation Manual MAXIMUM POWER POINT TRACKING Model: SS-MPPT-15L 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com

More information

WASP-P PRESSURE SENSOR

WASP-P PRESSURE SENSOR WASP-P PRESSURE SENSOR USER MANUAL VERSION 03.22 15/03/2016 WASP is a registered trademark owned by BossPac Engineering & Technology WASP is a PATENT PENDING technology owned by BossPac Engineering & Technology

More information

V-D2425 and V-D2440 Digital Clock

V-D2425 and V-D2440 Digital Clock Installation Manual V1.03 V-D2425 and V-D2440 Digital Clock Valcom, Inc. V-D2425 and V-D2440 Wired Clock Table of Contents Table Installation of Contents 2 Instructions Flush Mount Installation 3 3 Wall

More information

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa. INSTALLATION INSTRUCTIONS SUPERPLANE 2.5 Suspended A 1035 22nd Avenue, Unit 1 Oakland, CA 94606 P 510.489.2530 E TalkToUs@alwusa.com W alwusa.com SP2.5S - Safety & Warnings! 1. Read all instructions. 2.

More information

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité Manual for the Following Battery Charger Models: 1212, 1212OB, 2412, 2412OB, 3612, 3612OB, 3617, 3617OB,

More information

User s Manual ATTILA THE ANKYLOSAURUS TM VTech Printed in China US

User s Manual ATTILA THE ANKYLOSAURUS TM VTech Printed in China US User s Manual ATTILA THE ANKYLOSAURUS TM TM 2012 VTech Printed in China 91-002772-000 US Hi Friend, You re about to embark on a dino-mite adventure with me, Attila the Ankylosaurus! Just so you know, I

More information

X7298. fisher-price.com WARNING

X7298. fisher-price.com WARNING X7298 WARNING To prevent entanglement injury, never place gym in a crib or playpen. Never add strings, ties or other products to the gym. Please keep this instruction sheet for future reference, as it

More information