LEAB ChAmp. Product Specification. Idavägen Växjö Tel Fax Art 00438XX 00338XX
|
|
- Richard Fitzgerald
- 1 years ago
- Views:
Transcription
1 Product Specification Idavägen Växjö Tel Fax LEAB ChAmp Art 00438XX 00338XX
2 General description This Primepower product is a high efficient, intelligent and very compact battery charger. Suitable for all Lead acid batteries. It is a switch mode design and includes the latest component and technology in power conversion. The internal electronics controls the charging phase. The charging phases are monitored and adjusted continuously during the charging process. The product is suitable both in marine and automotive applications. Features Latest MosFET technology High efficiency, Cool running normal operation Adaptable to different battery types Waterproof and shock resistant, IP67 Powder coated Metal enclosure Small and easy to install Part number / order information Primepower part number Specification V / 17A V / 12A V / 17A Temp V / 12A Temp V / 30A Temp V / 20A Temp 110V version on request Numbers shows the basic standard models Different charging algorithms or cables results into other article numbers.
3 Theory of operation The Primepower LEAB champ family is one of the most compact battery chargers available. The input AC voltage is feed through a passive PFC stage and converted into a DC Voltage of approx 350V. A high frequency switch into a low dc voltage does the power conversion. This voltage is controlled by the internal electronics and rectified to a correct charging voltage on output. Block Diagram champ PFC AC/DC Power converter Rectifier DC output AC input Power control Charging control Charging algorithm Depending on program, please see the below descriptions
4 Above values only / Below value for models with tempsense The temp sensor is integrated in the black cable connector (minus) Following charging curves is available:
5 GEL AGM Traction Descriptions of features
6 The complete electronics are covered in polyurethane. Water, oil or other substances will thereby be effectively kept out. The champ can be mounted in very harsh environment such as engine-compartment due to the encapsulation. Before potting different charging algorithms can be applied and customized chargers can be made upon request. Temperature sensor is built in on the temp version, located in the black cable shoe. This ensures the correct charging voltage in cold or warm environment. Optional feature The charger has a build in relay which can be used to control external features (start protection, external relays) Electrical specifications ABSOLUTE MAXIMUM RATINGS Maximum ratings establish the maximum electrical rating to which the unit may be subjected without damage Parameter Value Units Notes Output Current / Voltage 18 A V A V Stand off voltage 20 V Nom 12V Stand off voltage 40 V Nom 24V Heat Sink Temperature 65 C Operating Temperature Range -25 C C Storage Temperature Range -55 C- 85 C Fuse A Fuse A Electrical Characteristics Unless otherwise stated, conditions apply to full temperature range and full input voltage range. Characteristic 230V MIN TYP MAX Unit Notes: Input Voltage VAC 1 Input Over Voltage 285 VAC Input voltage frequency 40-60Hz Quiescent Current off <1 ma Quiescent Current on 150 ma Efficiency 91% Voltage rippel mv Environmental Specifications
7 Parameter Level Conditions / Notes Humidity Splash Pressure Wash %RH Yes, IP67 Yes, IP67 Mechanical Vibration 40G according to standard IEC Handling Shock Will Show Damage Mechanical specifications The unit utilizes two 2,5mm2 (<17A) 6mm2 (>17A) Tin plated cupper cable making power connections. Cable mounted fuse on plus lead.(only / ) All models with temp sense is without fuse on battery cable. Length 1,5M. The AC connection is with standard rubber cord 3x0,75 1,5M. Finish: Grey RAL 7035, powder coated aluminium Potting material: Polyurethane Mounting Slots: 4X, Accepts M4-M5 (6mm diam) Hardware (not included) Weight: 1,6Kg Unit Dimensions: 195 x 98 x 47 Connection and installation: Mount the charger with LED:s facing up and cable downwards. This will maintain an efficient cooling and a maximum output current during the whole charging cycle. Do not extend charging cables. That may affect the charging result. Batteries can generate explosive gases - avoid open flames or sparks It is not allowed to modify the main cable. No reliability will be excepted for damages occurred by use without observation.
8 Low Voltage Directive, 2006/95/EC, the EMC Directive, 2004/108/EC, including Amendments by the CE marking Directive, 93/68/EEC The following harmonized European standards or technical specifications have been applied: Standards regarding EN Intertek SEMKO electrical safety EN ,SS Intertek SEMKO electrical safety EN :2000 Intertek SEMKO EMC emission EN :2000 Intertek SEMKO EMC immunity EN 50366:2003+A1 Intertek SEMKO EMF, magnetics
9 Ambient temperature deration curve All specification can be changed without prior notice
LEAB champ family 300W
Product Specification Idavägen 11 352 46 Växjö Tel +46 470 72 74 95 Fax +46 470 72 74 99 www.primepower.se LEAB champ family 300W Art 00438XX 00338XX General description This Primepower product is a high
LEAB Voltage converter
Product Specification Idavägen 11 352 46 Växjö Tel +46 470 72 74 95 Fax +46 470 72 74 99 www.primepower.se LEAB Voltage converter 0037195 General description This LEAB Voltage conditioner is designed for
Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC
Cxx Features: Universal AC input with active PFC Compatible with Lead Acid, Li-ion, Gel and AGM batteries Support optional remote controller (CR-) Voltage / temperature compensation with battery temp.
600W Intelligent Single Output Battery Charger 21A 10.5A VOLTAGE RANGE FREQUENCY RANGE
Bauart gepruft Sicherheit egelma ge od o s be wac g 600W Intelligent Single Output Charger PB600 series SPECIFICATION SAFETY & EMC (Note 3) SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
GV-Boost Waterproof Manual
GV-Boost Waterproof Manual Waterproof Voltage Boosting Solar Charge Controllers with Maximum Power Point Tracking For models: GVB-8-Pb-36V-WP: GVB-8-Pb-48V-WP: 36V Lead-Acid/AGM/Gel/Sealed/Flooded 48V
Max. Output Power. Efficiency (1) 110Vac 220Vac. 450 ma 90 ~ 305 Vac 445 Vdc 200 W 92% EUC-200S045ST
LED Driver EUC200SxxxST 20110114 D Features Ultra High Efficiency (Up to ) Active Power Factor Correction (0.99 Typical) Constant Current Output Lightning Protection AllRound Protection: SCP, OTP, OVP
Industrial PFC UPS System
Based on Statron s leading A.T.I.S. (Advanced Technology Industrial System) platform, the S3000 range is a true-industrial UPS system using the latest Power Factor Corrected (PFC) IGBT rectifier technology.
GV-Boost Manual. 8A Input / W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking
GV-Boost Manual Solar Charge Controllers with Maximum Power Point Tracking For models: GVB-8-Pb-12V: GVB-8-Pb-24V: GVB-8-Pb-36V: GVB-8-Pb-48V: GVB-8-Li-**.*V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded 24V Lead-Acid/AGM/Gel/Sealed/Flooded
Pressure transmitter for industrial applications Type MBS 4500
MAKING MODERN LIVING POSSIBLE Data sheet Pressure transmitter for industrial applications Type MBS 4500 The high accuracy pressure transmitter MBS 4500 is designed for use in almost all industrial applications,
CTE7000 / CTU7000 Series Miniature pressure transmitters
FEATURES 10 mbar to bar, 0.1 to 7 psi gage 1 pressure 0..., 0...10, 0...4., 1...6 or 4...20 ma output Field interchangeable Rugged stainless steel housing EMC according to EN 61326-1 9 MEDIA COMPATIBILITY
Mass Sine 24/10000 Mass Sine 24/15000
USERS- AND INSTALLATION MANUAL Mass Sine 24/10000 Mass Sine 24/15000 Modular high power inverter system MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands ENGLISH: PAGE 1 Tel.: +31-20-342
INDUSTRIAL POWER SUPPLIES SFL-SERIES
INDUSTRIAL POWER SUPPLIES SFL-SERIES Operating Instructions 1. Application The SFL-series are compact, rugged switching power supplies designed for applications in process automation and other industrial
1000W Intelligent Single Output Battery Charger PB PB PB V 28.8V 57.6V 13.8V 85% 88% 89%
PB000 series SPECIFICATION MODEL OUTPUT INPUT PROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note ) OTHERS NOTE BOOST CHARGE VOLTAGE FLOAT CHARGE VOLTAGE OUTPUT CURRENT RECOMMENDED BATTERY 00 ~ 600Ah CAPACITY(AMP
Pressure transmitter for marine applications MBS 33M
Data sheet Pressure transmitter for marine applications MBS 33M The standard pressure transmitter MBS 33M is designed for use in almost all marine applications, and offers a reliable pressure measurement,
TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)
LOCAL Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)
BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL
BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1 IMPORTANT
SCXI Power Supply/Float Charger Installation Guide
SCXI -1383 Power Supply/Float Charger Installation Guide Conventions This guide describes how to install and use the SCXI-1383 power supply/float charger. The SCXI-1383 is a 13.8 VDC, 4 A power supply/float
UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS
BATTERY MODULE 24V, 7Ah Battery Capacity (2x 12V Batteries in Series) Small Mounting Footprint 2m Power Leads Included PT1000 Sensor for Battery Module Temperature Included Includes a Center-tap Terminal
Intelligent Charging System Series
R Intelligent Charging System Series OWNER S MANUAL ON BOARD BATTERY CHARGERS Models Amperage No. Of Banks Volts 16061 s 1 Bank 12 16102 6,s 2 Banks 12 or 24 16153 6,6,s 3 Banks 12 or 24 or 36 16202 10,10
FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units
THE DIN-A-MITE FAMILY 1 Refer to curves on reverse side for specific ratings. ➁ angle fire is not CE approved for conducted or radiated emissions. ➂ Will fit within the width dimension of most comparable
MINI MCR-SL-UI-UI(-SP)(-NC)
Configurable 3-Way Isolating Amplifier Data Sheet 04/2005 Functions Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP)(-NC) is used to electrically isolate, condition, amplify,
Don't let the shadows of yesterday hide the sunshine of tomorrow Nandina Morris
Don't let the shadows of yesterday hide the sunshine of tomorrow. -------------- Nandina Morris Hybrid MPPT Solar Inverter Main Features Pure sine wave inverter Built-in MPPT solar charge controller Selectable
Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS
Application: The VISTA range of analog panel meters offers accurate measurement and indication of most electrical and electronic parameters in industry as per industrial standard case size. Available Models:
TECHNICAL DATA SHEET KVA UPS Systemss
Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800
Self-regulating frost protection system for pipes
AT-TS-13 60 30 90 0 C 120 Self-regulating frost protection system for pipes eliability: protects your pipes from frost damage Maintenance-free Efficient energy use FS-A-2X: 10 W/m at 5 C FS-B-2X: 26 W/m
Type A-10 General Purpose Pressure Transmitters
Type A-10 General Purpose Pressure Transmitters Applications Mechanical engineering Machine tools Process control and automation Hydraulics and pneumatics Pumps and compressors Special Features Pressure
ID ID. Series 19. Mechanical Products Company
H i g h A m p e r a g e 2 5 t o 2 0 0 A M P New LED tripid ID ID TM Option T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 & I P 6 9 K W a t e r p r o o f I g n i t i o n - P r o t e c t e
CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media
FEATURES mbar to 35 bar, 15 to 500 psi gage 1 or absolute 10 pressure 05, 010, 0545, 16 or 420 ma output Field interchangeable All welded stainless steel diaphragm construction EMC according to EN 61326-1
UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.
BATTERY MODULE Long Life Battery: 10 to 12 Years According to EUROBAT Small Mounting Footprint Easy Access to the Terminals and the Fuse Heavy Duty Fuse Holder and Spare Fuse Included 3 Year Warranty,
POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting
POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running
MINI MCR-SL-UI-UI(-SP)
Configurable 3-Way Isolating Amplifier Data Sheet 11/2004 Product Description Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP) is used to electrically isolate, condition, amplify,
Product Specification 21XXXE00 EQUALIZER AND 21XXXC00 CONVERTER FAMILY
ISIONS ECO DESCRIPTION DTE BY 001 5332 PRODUCTION RELESE 11/26/08 JT 5489 DD 21100C00 MODEL NUMBER CLRIFY EQULIZER S OUTPUT VOLTGE DURING NO-LOD CHG SLES/MRKTG PPROVL BLOCK TO PROD MNGER PPROVL BLOCK 10/15/09
Thermal Overcurrent Circuit Breaker 3120-F...
Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of
PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations
Standalone three-phase UPS system PowerWave 33 S3 60 120 kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations Innovative technology delivering unmatched
PRODUCTS: POWER SUPPLY
PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER
VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA
P Temperature monitoring (PTC) Short-circuit monitoring Supply voltage 24-240 V AC/DC 1 normally open contact Width 22,5 mm Status indication LED U: Supply voltage LED TFailure: Temperature failure TECHNICAL
FL ballasts Electronic fixed output. PC TC PRO 1/2x9 70 W PC PRO compact
EL HE PC TC PRO 1/2x9 70 W PC PRO compact Product description CELMA Energy Efficiency Index A2 BAT / A2 Nominal life-time up to 100,000 h (at ta 50 C with a failure rate max. 0.2 % per 1,000 h) Large temperature
Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050
Data sheet Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050 The compact pressure transmitter, type MBS 3000, is designed for use in almost all industrial applications, and offers
THERMAL MANAGEMENT
DESIGN GUIDELINES XL-TRACE LSZH SELF-REGULATING HEATING CABLES FOR PIPE FREEZE PROTECTION SYSTEMS THERMAL MANAGEMENT WWW.PENTAIRTHERMAL.COM PIPE FREEZE PROTECTION SYSTEM OVERVIEW SBS Control Panel T-Connection
ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.
ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance
Electronic Circuit Breaker ESS20-0..
Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode
Aurora Wind Interface Box
Aurora Wind Interface Box Installation and Operator s Manual Page 2 of 15 REVISION TABLE Document Revision Author Date Change Description 1.0 T. Melzl 5/9/2006 First release of the document SAVE THESE
Standalone three-phase UPS system. PowerWave kw Unmatched power performance
Standalone three-phase UPS system PowerWave 33 60 500 kw Unmatched power performance PowerWave 33 the powerhouse ABB has always set global standards in uninterruptible-powersupply solutions. The latest
FL ballasts Electronic fixed output. PC BASIC sl, 4 28 W PC BASIC
T8 c PC BASIC sl, 4 28 W PC BASIC Product description CELMA Energy Efficiency Index A2 / A3 Nominal life-time up to 50,000 h (at max. ta with a failure rate max. 0.2 % per 1,000 h) Large temperature range
ALPHA S NEXT-GENERATION UNINTERRUPTIBLE POWER SUPPLY
ALPHA S NEXT-GENERATION UNINTERRUPTIBLE POWER SUPPLY next-generation power From ground-breaking transformer design to the most intuitive and user-friendly interface in the industry, the XM3-HP sets the
2006/2007 Product Catalog. The World s Leading SOLAR Controllers
2006/2007 Product Catalog The World s Leading SOLAR Controllers OUR COMPANY Morningstar Corporation, founded in 1993, is the world s leading supplier of photovoltaic (PV) controllers. In 2005 we shipped
Temperature Controller (Heat Pumps)
3 345 Temperature Controller (Heat Pumps) For comfort control in HVAC systems RWD31 RWD41 Stand-alone electronic temperature controller Four 2-position (On/Off) outputs Easy adjustment of parameters via
Master MPS kva kva 3:1 3:3 VFI TYPE
DATACENTER E-MEDICAL INDUSTRY TRANSPORT EMERGENCY VFI TYPE ONLINE Master MPS 3:1 3:3 10-100 kva 10- kva 4 SmartGrid ready f lywheel compatible Supercaps UPS Service 1st start HIGHLIGHTS Efficiency Control
PowerMASTER M-frame GENERAL SPECIFICATIONS. DC connection. AC connection. Liquid cooled heavy duty inverter PRODUCT DATA. Visedo PowerMASTER features:
PowerMASTER M-frame Liquid cooled heavy duty inverter PRODUCT DATA Visedo PowerMASTER features: Extremely compact design 300 kw unit only 15 kg High enclosure class IP67 sealed from moisture and dust Liquid
AXS 215S: Continuous actuator for unit valves, with stroke indicator
AXS 215S: Continuous actuator for unit valves, with stroke indicator How energy efficiency is improved Reliable, precise actuation in efficient control systems Features Fitted to the valve using no force
Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions
Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester Charge & Testing Integrated Electronic Solutions Connect Multimediality The new ADELSystem platform communication ADELBus
BlueSolar charge controller MPPT 100/30
Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Användarhandbok SE Appendix BlueSolar charge controller MPPT 100/30 1. General Description 1.1 Charge current up to 30 A and PV voltage up to 100
ABB Component Drives ACS150, 0.5 to 5 Hp
ABB Component Drives ACS150, 0.5 to 5 Hp Technical Catalog BUSINESS PROFILE INDUSTRIES PRODUCTS APPLICATIONS EXPERTISE PARTNERS SERVICES Contents Choice 1: Simply contact your local ABB drives sales office
Inline filter with filter element according to DIN 24550
Inline filter with filter element according to DIN 24550 RE 51422/07.11 Replaces: 12.10 1/18 Type 350LEN0040 to 1000; 350LE0130, 0150 Size according to DIN 24550: 0040 to 1000 Additional sizes: 0130, 0150
C3 Operating Instructions
Version 3.1 Stand 09.2014 Robert Bosch (Australia) Pty. Ltd. 1555 Centre Road Clayton, Victoria 3168 C3 Operating Instructions For further information please contact Bosch at: Australia 1300 30 70 40 www.boschautoparts.com.au
DKG-114 MANUAL AND REMOTE START UNIT
DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional
AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL
INSTRUCTION MANUAL AUTO CHARGE D2 AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-74-12 INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY 1
Phoenix Inverter
Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC
NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.
Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high
The breakers offer thermal-magnetic trip protection according to Z and K characteristics.
Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific
PowerScale kva Technical Specifications
PowerScale 10-50 kva Technical Specifications Copyright 2015 ABB, All rights reserved. TABLE OF CONTENTS 10.1 POWERSCALE SYSTEM DESCRIPTION... 3 10.2 TECHNICAL CHARACTERISTICS... 4 10.2.1 MECHANICAL CHARACTERISTICS
LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request
The shelf consists of a ruggedized Battery Charger, PSU with a 3-phase input for 400 / 480 VAC (line to line) and with an output suitable for 110V battery charging. DC-DC stage to convert the 3-phase input
Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor
Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient
PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE
Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option
J1000. Compact Inverter Series.
J1000 Compact Inverter Series www.yaskawa.eu.com Focus on Application Customer orientation and application focus two attributes of machine equipment YASKAWA offers with its J1000 compact inverter drive
Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)
PSC9733 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression
Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.
X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off
PSU EN54-4 Power Supplies
PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in
PC T8 PRO, W T8 fluorescent lamps
T8 PC T8 PRO, 18 70 W T8 fluorescent lamps Product description Average life = 50,000 hours (at max ta. with a failure rate 0.2 % per 1,000 hours) Large temperature range (for values see table) Safety shutdown
Electrical Actuators
OEM Electrical Actuators SSY319 for valves VXG48, VXB489R, VXI48 VVP459, VXP459, VMP459, VVG549 AC 230 V operating voltage, 3-position control signal Positioning force 300 N Manual override with indication
Electronic Circuit Breaker ESS20
Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode
AUTO CHARGE D PUMP PLUS
INSTRUCTION MANUAL AUTO CHARGE D PUMP PLUS AUTOMATIC DUAL OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-9-DPP INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY:
Technical Data Sheets
Digit al Energy T M L P Seri es Di gi ta l Energy TM LP Series Digita l Energ y T M L P Se rie s GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply
Control solutions Biofloor
ACTUONOFF Actuator ON/OFF Normally Closed for valves and manifolds Application Actuation of common valves, for example Comap thermostatic valves for radiators, Ballorex Dynamic valves and underfloor heating
Power Supplies. Series FLEX Power Supplies...P2 Technical Information & Dimensions (Online)...P5. ADEL Power Supplies
ower Supplies Series...2 Technical Information & Dimensions (Online)...5 ADEL ower Supplies 1 Flexible Switching ower Supplies Sprecher + Schuh is proud to bring you a Flexible ower Supply from the best
SDS Enclosed Star-Delta Starter User Guide
SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING
Manual. EN Appendix. Blue Smart IP65 Charger 120V 12/7 12/10 12/15 24/8
Manual EN Appendix Blue Smart IP65 Charger 120V 12/7 12/10 12/15 24/8 IMPORTANT SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for Blue
GEBRUIKERSHANDLEIDING / USERS MANUAL BETRIEBSANLEITUNG / MODE D EMPLOI ALPHA PRO
- 1 -- 1 - GEBRUIKERSHANDLEIDING / USERS MANUAL BETRIEBSANLEITUNG / MODE D EMPLOI ALPHA PRO MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com
Inline filter with filter element according to DIN 24550
Inline filter with filter element according to DIN 24550 RE 51448/06.11 Replaces: RE 51400 1/18 Type 110LEN0040 to 0400; 110LE0130, 0150 Size according to DIN 24550: 0040 to 0400 Additional sizes: 0130,
Inline filter with filter element according to DIN 24550
Inline filter with filter element according to DIN 24550 RE 51421/07.11 Replaces: 12.10 1/16 Type 245LEN0040 to 400; 245LE0130, 0150 Size according to DIN 24550: 0040 to 0400 Additional sizes: 0130, 0150
Installation Instructions - K-Safe-T-Rip Belt Rip Detector
Kinder Australia product: Preferred Setup Instructions Note: The correct Belt Rip pick up detachment operation of the Rip Socket, is in a sideways motion to the attachment point. This means once the Socket
Piston Pumps with Reservoir
Piston Pumps with Reservoir 1-0107-2-US for grease up to NLGI grade 2 with electric drives for progressive and multiline systems KFA1 / KFA10 KFG1-5-W2-M KFGS30-5 Because of their delivery rates and reservoir
MPPT Solar Charger With Constant Current Driver
KMPA200JU SERIES MPPT Solar Charger With Constant Current Driver Professional for the solar street light system MPPT efficiency 99.9% Constant current driving power: 100W(12V), 200W(24V) 3 Year Warranty
MKN-DSP SERIES - THREE PHASE
Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /
Super PWRgate PG40S Spring City Drive Waukesha, WI
Super PWRgate PG40S www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 sales@westmountainradio.com 2015, All rights reserved. All trademarks are the property of their respective
Technical Documentation
Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that
TZIM. Electropneumatic Analog Positioner 10/ EN
TZIM Electropneumatic Analog Positioner EP001XA.tif Q Convenient, simple design Q Easy to handle Q User-friendly operation, easy to understand Q Reliable concept, I/P conversion through the 500,000 times
LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL
INSTRUCTION MANUAL LPC 20 LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-207-12 INPUT: 120 Volt, 50/60 Hz, 7 Amps OUTPUT: 20 Amps File:
EUROTHERM ONTROLS. Two phase thyristor power switches. Product data
TC2000 TC2001 EUROTHERM ONTROLS Two phase thyristor power switches Product data TC2000 TC2001 Thyristor power switches Compact, two phase thyristor power switches for electrical heating applications from
ABB industrial drives ACS800, single drives, 0.55 to 5600 kw
ABB industrial drives ACS800, single drives, 0.55 to 5600 kw Technical catalogue PROFILE INDUSTRIES PRODUCTS APPLICATIONS EXPERTISE PARTNERS SERVICES Contents 1 2 Type code Product series Single drives
Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger
Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,
SPECIFICATIONS SRF SuperchargerPlus
SPECIFICATIONS - 2412SRF Totally Automatic Switch-Mode Battery Chargers "Suitable for Gel, Sealed & Wet Lead Acid Batteries" Summary: 24 V, 6Amp Constant Current (equivalent to 12A tapered charger in charging
FL ballasts Electronic fixed output
T8 PC T8 PRO lp, PC T8 PRO sl, 18 58 W PC PRO T8 Product description Highest possible CELMA Energy Efficiency Index EEI = A2 BAT 21 0 Nominal life up to 100,000 h (at ta. 50 C with a failure rate max.
Resistance thermometer Model TR10-L, Ex d, for additional thermowell
Electrical temperature measurement Resistance thermometer Model TR10-L, Ex d, for additional thermowell WIKA data sheet TE 60.12 for further approvals see page 6 Applications Chemical industry Petrochemical
Digital Intelligent Battery Charger OPERARATOR S MANUAL
Digital Intelligent Battery Charger OPERARATOR S MANUAL WARNING! Before you install and use your Nitro Battery Charger, be sure to read and save these safety instructions. INTRODUCTION The Sinergex Nitro
PowerScale TECHNICAL SPECIFICATIONS
PowerScale TECHNICAL SPECIFICATIONS PowerScale highlights at a glance Best in class efficiency Cost savings during the entire life-cycle(tco) Low input harmonic distortion Cost saving during installation
Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)
817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global
Versatile and Rugged Industrial LIthium/LiPO Charger Series
Versatile and Rugged Industrial LIthium/LiPO Charger Series Description The M-series is an environmentally robust and sophisticated battery chargers with models supporting Lithium or LiPo batteries. With
DIAMOND POINT VIBRATING PROBES
DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527