ENGINEERED RACK SOLUTIONS
|
|
- Mariah Neal
- 6 years ago
- Views:
Transcription
1 ENGINEERED RACK SOLUTIONS FLEXIBLE MODULAR PREWIRED SPACE EFFICIENT /012/CD
2 Part Number RD02341 MBC " Welded Steel Relay Rack 43 Rack Spaces Max wt. limit 1000 lbs. 19" Relay Rack Tray for Front & Top Terminal 19" Relay Rack Tray for Top Terminal 19" Relay Rack Tray for Front Terminal 19" Relay Rack Tray for Top Terminal 19" Relay Rack Tray for Front Terminal Dimensions Standard x 84 H 16 W x 30 D 16 W x 16 D W x D 16.7 W x 20.2 D 17.9 W x 20.0 D N/A 2 max Any TEL1270, TEL1280, TEL1290, TEL1212, TEL1210FS, TEL12160F, TEL12180F, TEL6180, TEL12210F, TEL12210FG TEL1230 & TEL124, TEL1210FS, TEL12160F, TEL12180F, TEL12210F, TEL12210FG TEL1230, TEL124 LS12100, LS6200, LS4300 & LS2600 TEL1210FNSG (use.01) TEL1211FNG (use.02) N/A NEW /012/CD 2
3 Part Number KBC " Welded Steel Relay Rack 43 Rack Spaces Max wt. limit 1000 lbs. 23" Relay Rack Tray for Top Terminal 23" Relay Rack Tray for Front Terminal 23" Relay Rack Tray for Top Terminal Dimensions Standard x 84 H 20 W x 30 D 21.0 W x D 21.2 W x D N/A N/A TEL1230, TEL124, TEL1270, TEL1280, TEL1290, TEL1212 TEL1210FS TEL12160F TEL12180F TEL1210FNSG TEL1211FNG, TEL12210F, TEL12210FG LS12100, LS6200, LS4300 & LS2600 N/A /012/CD 3
4 battery TRAy TAbLE Battery Qty in Tray Part Number Qty in Tray Part Number TEL or MBC TEL or MBC TEL or TEL or TEL TEL TEL1210FS or RD TEL1210FNSG TEL1211FNG TEL12160F or RD TEL12180F or RD TEL6180 TEL12210F or RD TEL12210FG or RD NOTE: See tray/battery diagrams on pages & 6. Battery Qty in Tray Part Number Qty in 23 Tray Part Number 23 LS MBC KBC0182 LS MBC KBC0182 LS MBC KBC0182 LS MBC KBC0182 NOTE: See tray/battery diagrams on pages & /012/CD 4
5 TEL124 TEL124 TEL124 TEL124 TEL1212 TEL1290 TEL1212 TEL1212 TEL1212 TEL1270 TEL1280 TEL1270 TEL1270 TEL1280 TEL1280 TEL6180 TEL1290 TEL1290 TEL1230 TEL1230 TEL1230 TEL1230 ( ) ( ) TEL6180 TEL6180 TEL1290 TEL6180 TEL12210FG TEL12210FG TEL12210F TEL12210F TEL12180F TEL12180F TEL12160F TEL12160F TEL1210FS TEL1210FS TEL1270 TEL1280 LS12100 LS12100 LS2600 LS2600 LS4300 LS4300 LS6200 LS6200 TEL1230 TEL1230 TEL1230 TEL1230 TEL124 TEL124 TEL124 TEL124 (MBC ) (MBC ) (MBC ) (MBC ) (MBC ) (MBC ) /012/CD
6 TEL1212 TEL1212 TEL1212 TEL1212 TEL1230 TEL1230 TEL1230 TEL1230 TEL124 TEL124 TEL124 TEL124 TEL1270 TEL1270 TEL1270 TEL1270 TEL1280 TEL1280 TEL1280 TEL1280 TEL1290 TEL1290 TEL1290 TEL1290 TEL6180 TEL6180 TEL6180 TEL6180 TEL1210FS TEL1210FS TEL1210FS TEL1210FS TEL12160F TEL12160F TEL12160F TEL12160F TEL12180F TEL12180F TEL12180F TEL12180F TEL12210F TEL12210F TEL12210F TEL12210F TEL12210FG TEL12210FG TEL12210FG TEL12210FG TEL1270 TEL1270 TEL1270 TEL1270 TEL1280 TEL1280 TEL1280 TEL1280 TEL1211FNG TEL1211FNG TEL1211FNG TEL1211FNG TEL1210FNSG TEL1210FNSG TEL1210FNSG TEL1210FNSG TEL12180F TEL12180F TEL12160F TEL12160F TEL1210FS TEL1210FS TEL1211FNG TEL1211FNG TEL1211FNG TEL1211FNG TEL1210FNSG TEL1210FNSG TEL1210FNSG TEL1210FNSG (RD02341) (RD02341) (RD02341) ( ) ( ) LS12100 LS12100 LS12100 LS4300 LS6200 LS6200 LS6200 LS4300 LS4300 LS2600 LS2600 LS2600 LS12100 LS6200 LS4300 LS2600 (KBC0182) (KBC0182) (KBC0182) (KBC0182) /012/CD 6
7 Part Number A " Welded Steel Rack with 3 Integrated Battery Trays (shown with optional DC plant). 23" Welded Steel Rack with 4 Integrated Battery Trays (shown with optional RD02319xxx side mounted breakers & DC plant). 19 Welded Steel rack with 4 Integrated Battery Trays (Shown with optional side mounted breakers and DC Plant) 24 Volt NEBS Zone 2 24 Volt NEBS Zone 2 Rack w/breakers Dimensions 24 W x 22. D x 83 H 24 W x 22. D x 83 H 20.2 W x 20. D x 84 H 2"W x 23"D x 82.1"H 2 W x 23 D x 82.1 H Battery Tiers max 16 max 16 max TEL1210FS, TEL12160F, TEL12180F, TEL12210F, TEL12210FG TEL1210FS, TEL12160F, TEL12180F, TEL12210F, TEL12210FG TEL1210FNSG, TEL1211FNG TEL 12160F or TEL 12180F TEL 12160F or TEL 12180F, TEL12210 F System Voltage or 48V or 48V 48V 606AH Max (48V) 1212AH Max () 808AH Max (48V) 1616AH Max () 432AH Max 2020AH Max 2020AH Max NEW /012/CD 7
8 Part Number Volt NEBS Zone 2 48 Volt NEBS Zone 2 Rack w/breakers 48 Volt NEBS Zone 2 Rack w/breakers 24 Volt NEBS Zone 2 24 Volt NEBS Zone 4 Rack w/breakers 48 Volt NEBS Zone 4 Dimensions 2"W x 23"D x 82.1"H 2"W x 23"D x 82.1"H 2 W x 23 D x 82.1 H 26"W x 24"D x 81"H 26"W x 24"D x 81"H 26"W x 24"D x 81"H Battery Tiers 2 TEL 12160F, TEL 12180F, TEL12210F TEL 12160F, TEL 12180F, TEL12210F TEL 12160F or TEL 12180F, TEL12210 F/FG TEL 12160F, TEL 12180F, TEL12210F TEL 12160F, TEL 12180F, TEL12210F TEL 12160F, TEL 12180F, TEL12210F System Voltage 1010AH Max 1010AH Max 1010AH Max 2020AH Max 2020AH Max 1010AH Max NEW /012/CD 8
9 Part Number (top bus) (top bus) (Rt Bus) (Left Bus) 48 Volt NEBS Zone 4 Rack w/breakers 24 Volt NEBS Zone 4 48 Volt NEBS Zone 4 24 Volt NEBS Zone 4 48 Volt NEBS Zone 4 24 Volt NEBS Zone 4 Top Plate for mounting electronics Dimensions 26"W x 24"D x 81"H 26"W x 24"D x 84"H 26"W x 24"D x 84"H 26 W x 2.3 D x 44 H 26 W x 2.3 D x 44 H 27 W x 2.3 D x 48 H Battery Tiers max 12 max 12 max TEL 12160F, TEL 12180F, TEL12210F TEL 12160F, TEL 12180F, TEL12210F TEL 12160F, TEL 12180F, TEL12210F TEL 12160F, TEL 12180F, TEL12210F TEL 12160F, TEL 12180F, TEL12210F TEL 12160F, TEL 12180F, TEL12210F System Voltage 48V 1010AH Max 2424AH Max 1212AH Max 1212AH Max 606AH Max 1212AH Max /012/CD 9
10 Part Number (RT SIDE BUS) (LFT SIDE BUS) Optional side mounted breaker/disconnect RD02319Lxxx xxx=amps RD02319xxx xxx=amps Dimensions Battery Tiers 48 Volt NEBS Zone 4 Rack w/term Bar Top Plate for mounting electronics 27"W x 2.3"D x 48"H 3 Low Profile 24 Volt NEBS Zone 4 Rack w/o Breakers 26"W x 2.3"D x 71"H Mounting Location Breaker Sizes Left Side mounted Available in 1 to 100 AMPS Sizes Right Side mounted Available in 1 to 100 AMPS Sizes 12 max TEL 12160F, TEL 12180F, TEL 12210F TEL 12160F, TEL 12180F, TEL 12210F System Voltage 606AH Max 2020AH Max 1400 Union Meeting Road P.O. Box 303 Blue Bell, PA (21) Fax (21) (800) customersvc@cdtechno.com Any data, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user s intended purpose and in user s specific application. Copyright 2012 C&D TECHNOLOGIES, INC. Printed in U.S.A /CD
Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C)
12-373 UL Recognized Component RETURN LEAD RECYCLE LIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY FOR STANDBY APPLICATIONS Capacities from 100 to 600 Ampere-hours (8 hours to 1.75 VPC) 343 to
More informationC&D VRLA Batteries Extended Run Time for Small UPS Machines
TECHNICAL BULLETIN 41-7954 C&D VRLA Batteries Extended Run Time for Small UPS Machines 41-7954/0112/CD www.cdtechno.com Small UPS machines, in the range of 400 to 2500 VA, are typically used to provide
More informationPURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell
-11 PURE LEAD PLUS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications 305-545 Watts per Cell FEATURES & benefits APPLICATIONS Data Centers Network Operations Centers Industrial
More informationLIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY For standby applications Capacities from 25 to 600 Ampere-hours
RETURN RECYCLE 12-373 LEAD LIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY For standby applications Capacities from 25 to 600 Ampere-hours UL Recognized Component C&D Technologies Powercom Division
More informationFEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1.
-1029 Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications. APPLICATIONS Data Centers Network Operations Centers Industrial Process Control Facilities Internet Housing Sites Semiconductor
More informationFEATURES & BENEFITS. 10 year design 25 C
41-27 Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications. TECHNICAL DATA FEATURES & BENEFITS 10 year design life @ 25 C Absorbent Glass Mat (AGM) technology for efficient gas
More informationUPS FEATURES & BENEFITS C&D Technologies flooded batteries are engineered to provide superior performance
12-1023 All Batteries Capacity tested to 100% H LEAD CALCIUM BATTERIES FOR UPS AND SWITCHGEAR APPLICATIONS CAPACITIES FROM 0.370 TO 7.523 KILOWATTS PER CELL L W C&D Technologies flooded batteries are engineered
More informationTECHNICAL BULLETIN Fig #1 - VRLA Battery Components. Intercell Welded Connection Strap joining neg. plates in parallel.
TECHNICAL BULLETIN 41-7264 IntegrIty testing The valve regulated lead acid (VRLA) battery has several components (Ref. Figure 1), all of which can deteriorate with storage conditions and normal as well
More informationLIBERTY 2000 SuperMAX For standby applications Capacities from 295 to 2000 Ampere-hours
RETURN RECYCLE 12-372 LEAD UL Recognized Component LIBERTY 2000 SuperMAX For standby applications Capacities from 295 to 2000 Ampere-hours C&D Technologies' Powercom Division valve regulated lead-acid
More informationInstallation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries
RS02046 Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries FOLLOW MANUFACTURER S PUBLISHED INSTRUCTIONS WHEN INSTALLING, CHARGING AND SERVICING BATTERIES.
More informationThe Birth of a Powerful Idea
you can depend on The Birth of a Powerful Idea In 1906, two high school seniors, Frank Carlile and Leon Doughty, envisioned a future where the new technology of electricity would power the nation into
More informationOnesource. Onecompany. The only. solution. The Integrated Rack System
Onesource. Onecompany. The only 10-966 solution. The Integrated Rack System innovative We simplify state-of-the-art standby power. To our telecom and utility clients, time is literally money. That s why
More informationUPS FEATURES & BENEFITS TECHNICAL DATA Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications.
41-9027 Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications. TECHNICAL DATA FEATURES & BENEFITS 10 year design life @ 25 C Absorbent Glass Mat (AGM) technology for efficient gas
More informationGM Specification Annual Test Data
GM Specification Annual Test Data GM Specification Annual Test Data Technical Bulletin The 3M IATD Quality Laboratory tested the following tapes to the Automotive Specification. The results of the testing
More informationGM Specification Annual Test Data
GM Specification Annual Test Data GM Specification Annual Test Data Technical Bulletin The 3M IATD Quality Laboratory tested the following tapes to the Automotive Specification. The results of the testing
More informationSTANDBY BATTERY LI TEL48-170C INSTALLATION AND OPERATING MANUAL
STANDBY BATTERY LI TEL48-170C INSTALLATION AND OPERATING MANUAL Before handling or storing the battery take time to read this manual. It contains information that could avoid irreparable damage to the
More informationGRANITE ENCLOSURES MODEL NO. NPS Standard Features
MODEL NO. NPS-6-- --0666 Standard Features CSA and NEMA 3R (UL50) 1800 Amps @ 24Volt / 900 Amp @ 48Volt back up power Solid steel frame and shelf construction with 2 high sub-frame platform. Available
More informationand other -48VDC Power Systems. 19 or 23 Wide (Nominal) Relay Rack (part of system).
SYSTEM OVERVIEW Description: Application: Spec. Nos.: 588820100 (19 ). 588820200 (23 ). Models: 48BA1200-19 (19 ). 48BA1200-23 (23 ). Output Voltage: Capacity: Spec No. 588820100 (Model 48BA1200-19) Spec
More informationNetSure 5100 ORDERING GUIDE. 48V & 24V DC Power System (40 A to 600 A)
NetSure 5100 ORDERING GUIDE 48V & 24V DC Power System (40 A to 600 A) NETSURE 5100 ORDERING GUIDE Description The NetSure 5100 Series, a compact -48 volt 600 A DC power solution, features an advanced control
More informationSSC Sensor Replacement Board for the SSC Evaluation Kit. Features. Benefits
SSC Sensor Replacement Board for the SSC Evaluation Kit ZSC31XXX / ZSSC3XXX Datasheet Brief Description The SSC Sensor Replacement Board is included in IDT s modular SSC Evaluation Kits, which provide
More informationInstallation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries
RS-2046 Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries FOLLOW MANUFACTURER S PUBLISHED INSTRUCTIONS WHEN INSTALLING, CHARGING AND SERVICING BATTERIES.
More informationInstallation Instructions for R-Frame G-Series (RG) 310+ Trip Unit
Instruction Leaflet IL01210020E Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit Contents Description Page 1. Removal of R-Frame Electronic Seltronic (RES) Trip Unit and Obsolete Components...
More informationDetailed Specifications & Technical Data
For more information please call 1-800-Belden1 See Put-ups and Colors Description: FiberExpress Patch Panels in rack and wall mount with Splice Tray and SUITABLE APPLICATIONS: Suitable Applications OUTLET
More informationAll products subject to this warranty must be returned for examination, repair or replacement to:
Limited Warranty The software and sensors are warranted by the manufacturer, Toledo Integrated Systems, to be free from defects in workmanship for one year from the date of manufacturer s shipment. This
More informationModels DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007
B R A N D Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email:
More informationDiaphragm Pumps & Accessories
DIAPHRAGM PUMPS Diaphragm Pumps & Accessories Delavan Powerflo Diaphragm pumps offer a wide range of products from 1 gallon per minute to 7 gallons per minute, meeting all your agricultural and industrial
More informationS T C. STC Air Actuated Valves. Fine Quality. Precision Engineered Advanced Design. Excellent Prices. connects fluid power to industrial automation TM
Precision Engineered Advanced Design Catalog No.: PUB09KS STC Air Actuated Valves Fine Quality Excellent Prices connects fluid power to industrial automation Website: StcValve.com STC PNEUMATIC ACTUATED
More informationQuickSpecs. HP 480/277 Volt Solutions. Overview
Overview As the quest for efficiency continues it becomes apparent that what worked in the past needs improvement. More and more data center managers are looking at alternate power plans to distribute
More information505 Size 5 Series A Construction
505 Size 5 Series A Construction With Overload Relays Without Overload Relays Item Part Description Left-Hand Contactor Right-Hand Contactor Both Contactors No. Part Number Part Number Part Number 1 Stationary
More informationPURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell
UPS 12-1121 PURE LEAD PLUS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications 305-545 Watts per APPLICATIONS Data Centers Network Operations Centers Industrial Process Control
More informationSECTION
SECTION 26.10 2008-08 Page 1 2 10 11 9 4 8 4 7 3 1 5 6 Designed for High Performance and Sustainability 1 2 3 4 High capacity in a small footprint. Frees up valuable floor space for other equipment. Jar
More informationValve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS
12-1079 HIGH RATE MAX UPS 12-355MRF APPLICATIONS Data Centers Network Operations Centers Industrial Process Control Facilities Internet Housing Sites Semiconductor Manufacturing Banks & Financial Markets
More informationDigitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker
IL 33-LGH-1 Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker SAFETY PRECAUTIONS WARNING POWER CIRCUIT BREAKERS ARE EQUIPPED WITH HIGH SPEED, HIGH ENERGY OPERATING MECHANISMS. THE
More information3M Collision Repair Solutions. 3M Abrasives and Power Tools. Cutting & Grinding. for Body Techs
3M Collision Repair Solutions 3M Abrasives and Power Tools Cutting & Grinding for Body Techs 3M Disc Sander Ideal for general metal fabrication applications, including grinding, blending, weld leveling
More informationFlush Mount AIN ALPHA Meters. General. Hardware Kit
January 2003 IL42-4011B Flush Mount AIN ALPHA Meters General This leaflet contains installation instructions for mounting an AIN ALPHA meter in a semiflush configuration. A mounting kit, style number 1C11497G01,
More informationIMPORTANT INFORMATION
IMPORTANT INFORMATION Issue Date 2018 Catalog 4x4QR 2018 Please read the following important information before using this Catalog: ALWAYS CONSULT AND REVIEW THE ORIGINAL MANUFACTURERS INSTRUCTION MANUAL(S)
More informationProCS and ProC Series Heat Trace Panelboards
ProCS and ProC Series Heat Trace Panelboards Introduction Contents Introduction... 2 System Overview... 3 Certifications... 4 Heat Trace Panel Images... 4-5 AMC Heat Trace Panel (HTP) Selection Guide...
More informationAgilent N2763A Rack Mount Kit for 4000 X-Series Oscilloscopes
Agilent N2763A Rack Mount Kit for 4000 X-Series Oscilloscopes Installation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by
More informationInstructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version
IB131018EN Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version Contents Description Page 1. Introduction...2 2. Description...2
More information2V1-3V1 SERIES SOLENOID VALVE
2V1-3V1 SERIES SOLENOID VALVE Valve Model 2V1 3V1 Port & Mounting Body Ported, Stacking Action & Motion Solenoid, Direct Acting, 2 Way Response Time
More informationSTC Air Cylinders. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Air Cylinders
Catalog: PUB 06 CYL STC Advanced Design Precision Engineered Fine Quality Excellent Prices connects fluid power to industrial automation F1 Table of Contents STC Air Cylinder Numbering System............F2
More information3V SERIES SOLENOID VALVE
3V110-410 SERIES SOLENOID VALVE Valve Model 3V110-1/8 3V210-1/4 3V310-3/8 3V410-1/2 Port & Mounting Action & Motion Operating Pressure Body Ported Air Pilot, Spool Design, Response Time
More informationFeatures and Benefits
C&D Tubular GEL (OPzV) Series For Standby & Cyclic Applications C&D Tubular GEL (OPzV) Series range of valve regulated lead acid stationary batteries combine the benefits of recombination technology (i.e.
More informationDoor Edge Protection Film 36 inch
Door Edge Protection Film 36 inch Technical Data Sheet June, 2013 3M Part No.(s) PN 3M Part Descriptor(s) Door Edge Protection Film 36 inch Product Description 3M Door Protection Film is a super tough
More informationWestell FUSE PANEL. Technical Practice N Position Type VDC Floating
530-101760 REV C 0808-03C December 7, 2012 Westell FUSE PANEL Technical Practice 180108-N-0808 8 Position Type 70 130 VDC Floating FEATURES Single floating input distributing power via Type-70 fuses each
More informationSECTION A Division of Exide Technologies
SECTION 26.10 2015-02 A Division of Exide Technologies Page 1 2 10 11 9 4 8 4 7 3 1 5 6 Designed for High Performance and Sustainability 1 2 3 4 High capacity in a small footprint. Frees up valuable floor
More information3 Station Bike Rack Organization Center
H O L D I N G S, L L C 3 Station Bike Rack Organization Center Model No.: SBR300 This manual is designed to ensure that your new bike rack can be assembled successfully. Most people find that by setting
More informationQuickSpecs. HP Basic Power Distribution Units. Overview
Overview HP Basic PDUs are designed for simple installation, reliability and cost effective power distribution. They come in a variety of form factors and outlet configurations to meet the needs of today's
More information3M TM Cubitron TM II Bonded Abrasive Grinding and Cut-Off Wheels. born to. grind. It s grinding reinvented. Featuring. cut & grind wheels
3M TM Cubitron TM II Bonded Abrasive Grinding and Cut-Off Wheels. born to grind. It s grinding reinvented. Featuring NEW cubitron ii cut & grind wheels Grinding Reinvented 3M TM Cubitron TM II bonded abrasive
More informationGARLAND MODEL 680 s CANADIAN MODEL
GARLAND MODEL 680 s CANADIAN MODEL Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 361-7745 http://www.garland-group.com Form # 680 Canadian (Rev 04) Page 2 Form # 680
More information4V130P-430P SERIES AIR PILOT VALVE
4V130P-430P SERIES AIR PILOT VALVE Valve Model 4V130P-1/8 4V230P-1/4 4V330P-3/8 4V430P-1/2 Port & Mounting Action & Motion Operating Pressure Body Ported Double Solenoid, Spool Design, 3 Position, Pressure
More informationEF SERIES MOTORS OPERATION & PARTS MANUAL
EF SERIES MOTORS OPERATION & PARTS MANUAL Models S1, S2, S3, S4 S1, S2, S3 S4 EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following motors fully comply with the applicable
More informationRE-SLRSYS SAFETY, STORAGE, INSTALLATION, OPERATION & MAINTENANCE MANUAL
1 RE-SLRSYS SAFETY, STORAGE, INSTALLATION, OPERATION & MAINTENANCE MANUAL NANO-CARBON ENHANCED VRLA BATTERY LB022-V000-0000-06 JUNE 11, 2018 GS BATTERY www.gsbattery.com 2 THIS MANUAL PROVIDES MANUFACTURER
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04
More informationSeries A Construction
Page 1 of 7 Knowledgebase Technote ID # Q18363 9/2/2003 505 Series A Construction 505 505 1495-F1 (1 N.O. auxiliary contact) 1495-G5 (1 N.C. early break auxiliary contact) 1495-H0 ( 1 N.C. late break auxiliary
More informationDataSafe HX Top Terminated Batteries 6 and 12 Volt HX
DATASAFE HX TOP TERMINATED BATTERIES DataSafe HX Top Terminated Batteries 6 and 12 Volt HX Available exclusively from EnerSys, the world leader in stored power solutions. DataSafe HX Top Terminated Batteries.
More informationDS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1
New Information Supersedes Data 33-790-1H, dated October 1996 DS/DSII Low Voltage Switchgear Page 1 DS Switchgear Assembly DSII Switchgear Assembly Contents Pages DS Switchgear (Front View) 2 DSII Switchgear
More informationPatient Care Facility
ISIMET Patient Care Facility DLA Controller Individual Room Configuration Style 1 W/ Ver 4.41 pcb & Pulse Relay pcb Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for
More informationSTC 2P025 Series Solenoid Valve
STC 2P025 Series Solenoid Valve 2P025 Series Solenoid Valve Specifications Valve Model Valve Type Action Cv (Orifice) Operating Pressure Operating Temperature 2P025 2 Way, Normally Closed (NC) Direct Acting
More informationSimple Electrically Operated Ground & Test Device For use in Type VCP-W Switchgear rated up to 15kV, 25 and 40kA UPPER TERMINAL SET VERSION
Page: 1 Instructions for the Type VCP-W Ground & Test Device (Simple) Upper Terminal Set Version IB131007EN Effective May 2015 Simple Electrically Operated Ground & Test Device For use in Type VCP-W Switchgear
More informationVERTIV XTE 401 SERIES. Ordering Guide
VERTIV XTE 401 SERIES Ordering Guide VERTIV XTE 401 SERIES Description The Vertiv XTE 401 Series is a family of three small single sided low-cost indoor or outdoor rated aluminum enclosures. These versatile
More information3MTM CubitronTM II Bonded Abrasive Grinding and Cut-Off Wheels. BORN TO GRIND. IT S GRINDING REINVENTED.
3MTM CubitronTM II Bonded Abrasive Grinding and Cut-Off Wheels. BORN TO GRIND. IT S GRINDING REINVENTED. 13020160.indd 1 2/8/13 9:46 PM GRINDING REINVENTED 3MTM CubitronTM II bonded abrasive grinding and
More informationDrug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions
ISIMET Drug Testing Labs DLA Controller Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for Canadian Industrial Control
More informationwww. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers
Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers The National Electrical Code makes the following statement regarding ground fault conformance testing:
More informationQuickSpecs. HP Basic Power Distribution Units (bpdu) Overview
Overview HP Basic PDUs are designed for simple installation, reliability and cost effective power distribution. They come in a variety of form factors and outlet configurations to meet the needs of today's
More informationProportioning Unit evolution G-125 A / G-200 A
Proportioning Unit evolution G-125 A / G-200 A Issue 4.2 20/05/13 Ref. NR-00007-ENG Before installing the unit and starting it up, carefully read all the technical and safety documentation included in
More informationInstallation Instructions for Part #: KRB01 Radiator and Reserve Tank Relocation Kit for K-Powered Civics
Installation Instructions for Part #: KRB01 Radiator and Reserve Tank Relocation Kit for K-Powered 1992-1995 Civics This kit provides the SOLUTION for mounting a factory or factory replacement radiator
More informationHT40KX & HT50KX Accessories (Outriggers, Pedestals, Boom Rests)
TABLE OF CONTENTS HT40KX & HT50KX Accessories (Outriggers, Pedestals, Boom Rests) SECTION 100 DESCRIPTION& SPECIFICATIONS 23982 24962 / 25100 OUTRIGGER APPLICATIONS CHART 23984 INSTALLATION DRAWING- 24971-FP
More informationSECTION
SECTION 62.61 2005-07 Page 1 A WORLD LEADER IN VALVE REGULATED LEAD ACID (VRLA) BATTERY POWER FOR PHOTOVOLTAIC AND ALTERNATIVE ENERGY APPLICATIONS Proven Field Experience Since 1983. The Absolyte was developed
More informationModel NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006
B R A N D Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com
More informationProfessional Grade Agricultural Pumps.
Professional Grade Agricultural Pumps. 1 Delavan knows what HD Magnum PowerFLO PowerMAX 2 you need out of a pump. Turbo-90 RollerPRO 3 Sizing, Selection & Plumbing Diagrams How to Determine Pump Capacity
More informationInstruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod
Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod Eaton Corporation Moon Twp, PA. U.S.A. 15108 1 INTRODUCTION READ AND UNDERSTAND
More informationGE Sensing & Inspection Technologies. Model UTXDR. Panametrics Ultrasonic Flow Transducer. Installation Guide
GE Sensing & Inspection Technologies Model UTXDR Panametrics Ultrasonic Flow Transducer Installation Guide GE Sensing & Inspection Technologies Model UTXDR Panametrics Ultrasonic Flow Transducer Installation
More informationPatient Care Facility
ISIMET Patient Care Facility DLA Controller Individual Room Configuration Style 1 W/ Ver 4.41 pcb & Pulse Relay pcb Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for
More informationPage 1 of 9 Knowledgebase Technote ID # Q /24/2006
Page 1 of 9 Knowledgebase Technote ID # Q18356 3/24/2006 Bulletin 520F/520G Multi-Speed NEMA Starters with Eutectic Alloy or Solid-State Overload Relays Sizes 0 through 4 (all series), Size 5 (series L)
More informationInstallation and Operation Instructions Safety Director Arrow
Installation and Operation Instructions Safety Director Arrow! WARNING! Failure to install or use this product according to manufacturers recommendations may result in property damage, serious bodily/personal
More informationDrug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions
ISIMET Drug Testing Labs DLA Controller Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for Canadian Industrial Control
More information12110BESTPLACE CINCINNATI,OHIO PHONE FAX
12110BESTPLACE CINCINNATI,OHIO 45241 PHONE 1-800-226-2238 FAX 1-513-326-5427 www.venturo.com BLANK TABLE OF CONTENTS - 25100-PH(E) OUTRIGGERS - INSTALLATION MANUAL DESCRIPTION INSTALLATION SECTION 01 OUTRIGGER
More informationSTC 2L Series Solenoid Valves
STC 2L170-500 Series Solenoid Valves 2L170-500 Series Solenoid Valve Specifications Valve Model 2L170-3/8 2L170-1/2 2L170-3/4 2L200-1 2L300-1 1/2 2L500-2 Valve Type Action 2 Way, Normally Closed (NC) Pilot
More information4CR SERIES MOTOR STARTING RELAY All Position, Current-Type
4CR SERIES MOTOR STARTING RELAY All Position, Current-Type Product Description The Klixon 4CR current type motor starting relay is a compact, high capacity relay, designed for universal application to
More informationInstruction Manual. Forklift-Karrier
Instruction Manual Forklift-Karrier Note: The Owner/Operator must read carefully and understand all the information presented in this manual before using this device. - 0 - Contents 1. Figure and Parameter
More information3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive
3 3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive Technical Bulletin October, 2009 Description 3M Cushion-Mount Plus Plate Mounting Tapes with Easy Mount Adhesive incorporate several
More informationSECTION TECHNOLOGIES I NDUSTRIAL E NERGY
SECTION 62.61 2009-09 TECHNOLOGIES I NDUSTRIAL E NERGY Page 1 A WORLD LEADER IN VALVE REGULATED LEAD ACID (VRLA) BATTERY POWER FOR PHOTOVOLTAIC AND ALTERNATIVE ENERGY APPLICATIONS Proven Field Experience
More informationSTC. Manual & Actuated Process Valves. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Solenoid & Process Valves
Catalog: PUB 07A PV STC Manual & Actuated Process Valves Advanced Design Precision Engineered Fine Quality Excellent Prices D1 connects fluid power to industrial automation Table of Contents STC Process
More informationCE-104 TABLE OF CONTENTS CE-1500-FB OWNER'S MANUAL TABLE OF CONTENTS CE-1500-FB DESCRIPTION & SPECIFICATIONS DIMENSIONS AND CAPACITIES
TABLE OF CONTENTS CE500FB OWNER'S MANUAL SECTION 00 CE020 SECTION 50 DESCRIPTION & SPECIFICATIONS DIMENSIONS AND CAPACITIES SAFETY CE044 CRANE SAFETY AND HAZARDS 2376 DECAL DRAWINGS & LIST 2409 DECAL DRAWING
More information12110BESTPLACE CINCINNATI,OHIO PHONE FAX
20BESTPLACE CINCINNATI,OHIO 4524 PHONE 8002262238 FAX 533265427 www.venturo.com TABLE OF CONTENTS VC500FB OWNER'S MANUAL SECTION 00 CEV46 CEV62 DESCRIPTION & SPECIFICATIONS DIMENSIONS AND CAPACITIES WIRE
More informationModel LA 4300 Time Delay OFF Controller
ISIMET LA Series Model LA 4300 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller operates as a single output controller where the application
More information700 Type P & PK DC Relays Timer Units Latch Units Series A and B Construction. Renewal Parts
Page 1 of 5 Knowledgebase Technote ID # Q19373 3/10/2004 700 Type P & PK DC Relays Timer Units Latch Units Series A and B Construction Renewal Parts Figure 1 Page 2 of 5 Knowledgebase Technote ID # Q19373
More informationTB-690 Conveyor/Stacker
TB-690 Conveyor/Stacker ASSEMBLY AND OPERATIONS MANUAL Revised: 1-9-09 RENA SYSTEMS INC. 136 Green Tree Road STE 140 Oaks, PA 19456-1069 Phone: (610) 650-9170 Fax: (610) 650-9171 E-Mail: support@renausa.com
More informationDIAMOND P R O D U C T S
DIAMOND P R O D U C T S Parts List Manual Hydra-Gen 123 HP Power Unit with Electric Controls Part #: CC-HG-SK (January 2008) Part#: 1805052 Table of Contents Hydraulic Pump and Manifold 4 Hydraulic Tank
More informationINSTALLATION & OWNER'S MANUAL
INSTALLATION & OWNER'S MANUAL THE EAGLE POWER I BATTERY BACK UP PHONE (818) 764-6690 / TOLL FREE (800) 708-8848 PRE INSTALLATION INSTRUCTIONS BEFORE PROCEEDING WITH INSTALLATION READ THIS MANUAL THOROUGHLY
More informationTECHNICAL MANUAL RS02061
TECHNICAL MANUAL RS02061 Standby Batteries for Renewable Energy Applications Installation and Operating Instructions RS02061/0514/CD www.cdtechno.com Table of Contents Table of Contents 2 SAFETY PRECAUTIONS
More informationFinish Line. Redefining The. NEW 3M Elite Series Air-Powered Random Orbital/Orbital Sanders NEW 3M Electric Random Orbital Sanders
NEW 3M Elite Series Air-Powered Random Orbital/Orbital Sanders NEW 3M Electric Random Orbital Sanders Redefining The Finish Line 3M Elite Series Sanders NEW Elite Series Air-Powered Sanders and NEW Electric
More informationModel LA 4100 Time Delay OFF Controller
ISIMET LA Series Model LA 4100 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller operates as a single output controller where the application
More informationParts Manual (EN) COMMERCIAL CLEANING EQUIPMENT. Read the Operators Manual before using the machine.
COMMERCIAL CLEANING EQUIPMENT Parts Manual (EN) Read the Operators Manual before using the machine. Read the Safety Messages before servicing machine. www.tomcatequip.com 7 South Street Racine, WI 53404
More informationSECTION A Division of Exide Technologies
SECTION 62.61 2015-02 A Division of Exide Technologies Page 1 A WORLD LEADER IN VALVE REGULATED LEAD ACID (VRLA) BATTERY POWER FOR PHOTOVOLTAIC AND ALTERNATIVE ENERGY APPLICATIONS Proven Field Experience
More informationSECTION 26.10C
SECTION 26.10C 2008-08 Page 1 2 10 11 9 4 8 4 7 3 1 5 6 Designed for High Performance 1 High capacity in a small footprint. Frees up valuable floor space for other equipment. 8 Container and Cover - Polypropylene
More informationKompensator External Low Voltage Heating Cable System
External Low Voltage Heating Cable System LOW VOLTAGE Installation Instructions General Information Kit Contents Qty Description 1 heating cable at pre-determined length Table of Contents General Information........................
More informationINSTALLATION INSTRUCTIONS 5.7L HEMI TRUCK HOT-ROD STYLE. Also covers LX 5.7L/6.1L Hemi with Truck or Manual Transmission **
INSTALLATION INSTRUCTIONS 5.7L HEMI TRUCK HOT-ROD STYLE Also covers LX 5.7L/6.1L Hemi with Truck or Manual Transmission ** 5.7L Hemi Truck Hotrod Style Page: 2 5.7L Hemi Truck Hotrod Style Page: 3 Our
More informationAC* Series Ceiling Mount Air Handlers. The last letter of the model number represents the revision level; example: AC18-00C A is AC18-00C rev. A.
REPAIR PARTS Models covered in this manual AC18-00C AC18-00C A AC18-05C AC18-05C A AC18-05C B AC18-06C AC18-06C A AC18-06C B AC18-08C AC18-08C A AC18-08C B AC24-00C AC24-00C A AC24-05C AC24-05C A AC24-05C
More information