1 POWER SUPPLIES & RECTIFIERS TRANSFORMER RECTIFIERS The simple design of a transformer rectifier makes it one of the most reliable and durable forms of power supply. Another advantage is the easy maintenance due to very few electronic components. Usually the circuity would comprise a transformer, bridge-rectifier and output fuse for over-current protection. The term power supply would imply that the supply of power is regulated by means of an electronic control circuit. A transformer rectifier is generally unregulated i.e. the voltage can vary depending on the load current, but this is quite acceptable in many applications. TRANSFORMER RECTIFIER. 2x24VDC and 4x15VDC OUTPUTS This transformer rectifier is simple in design and cost effective. A 230VAC mains voltage is applied and the output DC voltage includes 2x24VDC and 4x15VDC outputs. 230VAC INPUT TO 24VDC OUTPUT

2 A simple single output voltage rectifier. We offer these rectifiers in an enclosure and at voltage and current specifications of your choice. 3-PHASE TRANSFORMER RECTIFIER. 400VAC 5 AMPS. We also offer a simple solution to obtain rectified 3 phase power. This transformer rectifier is powered by 400V 3-phase power and provides a single output of 5 Amps. A rectifier like this is suitable to mount into an existing cabinet and therefore does not need its own enclosure, which makes it more affordable.

3 POWER SUPPLIES We build power supplies in the following styles and according to customer requirements: Desktop: Ideal for laboratory and tertiary applications. Modular: 19 inch rack-mount. Ideal for a redundancy system. Mobile: The power supply is built into a cubicle with castor wheels. MOBILE POWER SUPPLY. 5 AMPS WITH HANDLES, CASTOR WHEELS AND PROTECTION LID These power supplies are designed to accommodate standard mains input supply voltages: 110VAC 230VAC 380VAC 525VAC Output voltages: 5VDC to 500VDC fixed or adjustable. Output current: 1 25 amps.

4 MOBILE POWER SUPPLY. 25 AMPS Power supplies like this are ideal for standby power on 110VDC systems when the main power supply or battery charger fails. These power supplies have kept railway signal stations online while the main source of power was being repaired. The voltage is variable between volts and the current limit can be adjusted between 0-25 amps to ensure that the load or batteries are protected. The front panel is vivid and easy to operate on all our mobile power supplies. MOBILE POWER SUPPLY CONTROL AND INDICATION PANEL

5 HIGH VOLTAGE POWER SUPPLIES. 3KV 3 KILO VOLT DC TO 24 VOLTS DC At some remote railway signal and relay rooms there is no 230V mains supply available. The only source of power is the 3kV DC form the overhead line. The high voltage connection of this unit is mounted up onto the 3kV mast which feeds the low voltage section installed in the signal room where 24VDC is generated.

6 30 KILO VOLT (30KV) AC INSULATION RESISTANCE (IR) POWER SUPPLY The insulation materials used on electrical devices eventually ages and therefore its insulating performance deteriorates. Any harsh installation environment, especially those with temperature extremes and/or chemical contamination accelerates this process. This deterioration can result in dangerous conditions in power reliability and personnel safety. As such, it is important to identify this deterioration quickly so that corrective steps can be taken. 500 VOLT DC 1 milli-amp (1mA) POWER SUPPLY This little high voltage and low current power supply was designed especially for the testing of laboratory equipment. Tell us what you need and we will design it accordingly.

7 BENCHTOP POWER SUPPLY. 10 AMPS. BENCH-TOP POWER SUPPLY 0-40 VOLT 0-10 AMP Power supplies like this are ideal for testing apparatus. Multi-turn adjustment knobs allow for very fine adjustments of the voltage and current outputs. Controlled voltage controlled current (CVCC) features are included.

PS24/AC Volt AC 16 Amp

PS24/AC Volt AC 16 Amp ALTERNATING CURRENT POWER SUPPLY PS24/AC-6 24 Volt AC 6 Amp FEATURES: Mains Fail Relay Output and Indicator. Fuse blow indication and relay output. 6 fused outlets DESCRIPTION: SPECIFICATIONS: Inputs Voltage-

More information

Biasing the Vintage Series (Nomad, BelAir, VT50, Vintage 33)

Biasing the Vintage Series (Nomad, BelAir, VT50, Vintage 33) Biasing the Vintage Series (Nomad, BelAir, VT50, Vintage 33) This chapter will outline and guide you through the procedures of biasing the Vintage series amplifier. The procedures are broken down in a

More information

Excel Series Value Engineered Access Hardware

Excel Series Value Engineered Access Hardware Excel Series Value Engineered Access Hardware Excel E1200 Economically Priced Alternative to Low Cost Imports Quality and Flexibility for Commercial Applications. The Excel product line is designed for

More information

A1P OPERATING MANUAL

A1P OPERATING MANUAL A1P OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty...

More information

How to bias: Vintage 16 Rev C 6/27/2012 carvinservice.com

How to bias: Vintage 16 Rev C 6/27/2012 carvinservice.com How to bias: Vintage 16 Rev C 6/27/2012 carvinservice.com - 1 - Only a certified technician should bias Carvin amps, this is very dangerous, you can get hurt, please be very careful when working with any

More information

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual Valcom Failsafe Unit 1620ESv2 SERIES Operation and Maintenance Manual Table of Contents Section Title Page 1. - Introduction.. 2. - Unpacking the Failsafe unit. 3. - Installation 3.1 - Auto / Timed UPS

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

ELSEMA Single / Double Gate Controller, for 12V / 24V Motor, GATCO12S, GATCO24S, GATCO12D, GATCO24D

ELSEMA Single / Double Gate Controller, for 12V / 24V Motor, GATCO12S, GATCO24S, GATCO12D, GATCO24D GATCO12S, GATCO24S, GATCO12D, GATCO24D Single / Double Gate Controller, for 12V / 24V Motor Features 4 Versions: 12V / 24V Single / Double Motor Application Control an automatic door or Gate GATCO12S 12V

More information

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C)

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C) 12-373 UL Recognized Component RETURN LEAD RECYCLE LIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY FOR STANDBY APPLICATIONS Capacities from 100 to 600 Ampere-hours (8 hours to 1.75 VPC) 343 to

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

TRANSMISSION SYSTEMS

TRANSMISSION SYSTEMS TRANSMISSION SYSTEMS Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution of electric

More information

OPERATION MANUAL TWE-375 CAPACITOR DISCHARGE WELDER

OPERATION MANUAL TWE-375 CAPACITOR DISCHARGE WELDER OPERATION MANUAL TWE-375 CAPACITOR DISCHARGE WELDER TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO 44677 (330) 725 7744 TWE@tfpcorp.com Version 1.0 Date 8/13/2013 TRU WELD EQUIPMENT

More information

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A) A Complete solution for small battery-backed dc instrument power systems. DATASHEET Supply 12Vdc 8A or 24Vdc 6A loads Ideal for RTU s, dataloggers, remote field instrumentation, alarm systems, etc. where

More information

LED Drivers A Practical Understanding for Lighting Applications. Dr. Adan Hernandez, Philips-Advance Al Marble, Philips-Advance

LED Drivers A Practical Understanding for Lighting Applications. Dr. Adan Hernandez, Philips-Advance Al Marble, Philips-Advance LED Drivers A Practical Understanding for Lighting Applications Dr. Adan Hernandez, Philips-Advance Al Marble, Philips-Advance Outline What is a driver? Design types Constant current vs. constant voltage

More information

Power Supplies DORMA PS

Power Supplies DORMA PS Power Supplies DORMA PS DORMA PS Power Supplies Main System On/Off or Fire Panel Relay - The power supply output voltage can be controlled by the main system on/off control relay which accepts a closed

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE 82013-800 January 2006 INDEX PAGE 1. General Information... 2 1.1 Description... 2 1.2 Safety precautions to be observed before operating the centrifuge...

More information

A Caspian Technology Company all materials presented are trade mark and copyright protected by C.M.TECHNOLOGY Pty Ltd

A Caspian Technology Company all materials presented are trade mark and copyright protected by C.M.TECHNOLOGY Pty Ltd PPS12 230v AC to 12 VDC POWER SUPPLY WITH BATTERY MANAGER OPTION 2 Table of Contents Introduction:... 3 1.0: Input Voltage:... 4 1.1: Mains Hold Up (missing mains cycles):... 4 1.2: Mains Input:... 4 1.3:

More information

ELSEMA 240VAC Slider Control Board, SLD

ELSEMA 240VAC Slider Control Board, SLD SLD Slider Control Board ELSEMA Features For Single 240VAC Motor Built-in transformer, auto close, open only, security close & special security close Application Control an automatic door or gate with

More information

How to bias: V3M, V3MC Rev A 9/23/2011

How to bias: V3M, V3MC Rev A 9/23/2011 How to bias: V3M, V3MC Rev A 9/23/2011 www.carvinservice.com - 1 - Only a certified technician should bias Carvin amps, this can be very dangerous, you can get hurt, please be very careful when working

More information

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave Rectifiers for use with Armature Actuated Brakes Product Overview NOTE: For brake response times with and without rectifiers see page 94. Full Wave A rectifier in which both positive and negative half-cycles

More information

Filtered PWM Speed Control for Permanent Magnet DC Motors

Filtered PWM Speed Control for Permanent Magnet DC Motors Instructions for Installation and Operation Filtered PWM Speed Control for Permanent Magnet DC Motors Model 0794 Speed and Direction Control up to 5/8 HP NEMA-1/IP-20 Specifications Product Type:... WPM-2148E1

More information

ELSEMA Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor, Enclosed, GATCOxxxCH

ELSEMA Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor, Enclosed, GATCOxxxCH GATCO12SCH, GATCO24SCH, GATCO12DCH, GATCO24DCH Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor Features 4 Versions: GATCO12SCH 12V Single motor GATCO24SCH 24V Single motor GATCO12DCH

More information

KILOVOLT POWER SUPPLY

KILOVOLT POWER SUPPLY Instruction Sheet for the PASCO Model SF-9586 KILOVOLT POWER SUPPLY 012-02815D 1/95 $1.00 SF-9586 KILOVOLT POWER SUPPLY ON kv HIGH VOLTAGE ADJUST OFF 6 KV 6.3 VAC CAUTION! HIGH VOLTAGE 3 KV 3 KV Introduction

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

0500 Low Voltage on the Battery or Dead Cell in the Battery

0500 Low Voltage on the Battery or Dead Cell in the Battery 0500 Low Voltage on the Battery or Dead Cell in the Battery Whenever you press the remote transmitter and you get one short beep from the control box, you press the remote and hear a warning buzzer but

More information

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / / Non-Regen Drives Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor.

More information

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016 DISTRIBUTED GENERATION CHAPTER 5 500. SCOPE This chapter includes distributed or customer-owned generation connected in parallel and operating with Alliant Energy s electric distribution system. For all

More information

Installation Instructions Central Battery Units

Installation Instructions Central Battery Units Phone: 605.542.4444 concealite.com! Installation Instructions s Please Save These Instructions Important Safeguards Read and Follow All Safety Instructions When using electrical equipment, basic safety

More information

SDS Enclosed Star-Delta Starter User Guide

SDS Enclosed Star-Delta Starter User Guide SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING

More information

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS MANUAL NUMBER: 64073 REV: 2 DATE: October 3, 2006 INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS AMERICAN BATTERY CHARGING, INC. P.O. BOX 17040 28 MAPLE AVENUE SMITHFIELD,

More information

Experiment 3: Ohm s Law; Electric Power. Don t take circuits apart until the instructor says you don't need to double-check anything.

Experiment 3: Ohm s Law; Electric Power. Don t take circuits apart until the instructor says you don't need to double-check anything. Experiment 3: Ohm s Law; Electric Power. How to use the digital meters: You have already used these for DC volts; turn the dial to "DCA" instead to get DC amps. If the meter has more than two connectors,

More information

Parts. WindyNation s 40 to 120 AMP Diversion Charge Controller Wiring Diagram (copyright 2009) 40 AMP Relay. Enclosure Charge Controller

Parts. WindyNation s 40 to 120 AMP Diversion Charge Controller Wiring Diagram (copyright 2009) 40 AMP Relay. Enclosure Charge Controller WindyNation s 40 to 120 AMP Diversion Charge Controller Wiring Diagram (copyright 2009) Parts 1 AMP fuse fuse holder Enclosure Charge Controller fuse fuse holder Female spade connectors Terminal connectors

More information

LEAB ChAmp. Product Specification. Idavägen Växjö Tel Fax Art 00438XX 00338XX

LEAB ChAmp. Product Specification. Idavägen Växjö Tel Fax Art 00438XX 00338XX Product Specification Idavägen 11 352 46 Växjö Tel +46 470 72 74 95 Fax +46 470 72 74 99 www.primepower.se LEAB ChAmp Art 00438XX 00338XX General description This Primepower product is a high efficient,

More information

Overview of the Grid-Saver Fast Energy Storage System

Overview of the Grid-Saver Fast Energy Storage System Overview of the Grid-Saver Fast Energy Storage System November 17, 2014 1 Introduction and Background Transportation Power, Inc. ( TransPower ) has developed a battery energy storage system called Grid-Saver,

More information

LEAB champ family 300W

LEAB champ family 300W Product Specification Idavägen 11 352 46 Växjö Tel +46 470 72 74 95 Fax +46 470 72 74 99 www.primepower.se LEAB champ family 300W Art 00438XX 00338XX General description This Primepower product is a high

More information

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 120628 REV. 007 2012 MTE Corporation Matrix Series D User s Manual 600VAC IMPORTANT USER INFORMATION NOTICE The MTE Corporation

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

8460SRC Replacement Chassis for Scully ST-6 and Biclops Monitors

8460SRC Replacement Chassis for Scully ST-6 and Biclops Monitors 8460SRC Replacement Chassis for Manual Part Number: OPTI-THERM is a registered trademark of CIVACON, A Dover Company QUICK-START is a registered trademark of CIVACON, A Dover Company Biclops is a registered

More information

MBCM-24 MULTIPLE BATTERY CHARGING MODULE (FOR MARINE APPLICATIONS) FEATURES SPECIFICATIONS APPLICATIONS DESCRIPTION & OPERATION ORDERING INFORMATION

MBCM-24 MULTIPLE BATTERY CHARGING MODULE (FOR MARINE APPLICATIONS) FEATURES SPECIFICATIONS APPLICATIONS DESCRIPTION & OPERATION ORDERING INFORMATION FEATURES Extends the trolling motor run time by charging the trolling motor batteries each time the boat s main engine is used. Automatically senses engine s alternator charge voltage, connects trolling

More information

General Purpose US Fuses

General Purpose US Fuses SMARTSPOT with Maximum circuit protection Amp-trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides

More information

LEAB Voltage converter

LEAB Voltage converter Product Specification Idavägen 11 352 46 Växjö Tel +46 470 72 74 95 Fax +46 470 72 74 99 www.primepower.se LEAB Voltage converter 0037195 General description This LEAB Voltage conditioner is designed for

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

QSSE, QSSEX INDUSTRIAL Battery Chargers

QSSE, QSSEX INDUSTRIAL Battery Chargers C O R P O R A T IO N O P E R A T I N G I N S T R U C T I O N S QSSE, QSSEX INDUSTRIAL Battery Chargers INTRODUCTION The QSE line are electronically controlled float chargers. The batteries are brought

More information

SCHALTBAU CONNECTIONS ALL FROM ONE SOURCE

SCHALTBAU CONNECTIONS ALL FROM ONE SOURCE SCHALTBAU CONNECTIONS ALL FROM ONE SOURCE SCHALTBAU CONNECTIONS PRE-ASSEMBLED CONNECTORS Schaltbau connectors assembled as set Whether it is for railway vehicles, charging stations of modern li-ion batterypowered

More information

Maxum II Modular Oven Automatic Purge Control Unit Product Update PU-002

Maxum II Modular Oven Automatic Purge Control Unit Product Update PU-002 Maxum II Modular Oven Automatic Purge Control Unit Product Update PU-002 Revision History Issue Date Reason 001 6/15/2016 Initial Issue Copyright Siemens AG 2015 All rights reserved atable of Contents

More information

INTELEPOWER CXS SWITCHING SYSTEMS

INTELEPOWER CXS SWITCHING SYSTEMS INTELEPOWER CXS SWITCHING SYSTEMS INTELEPOWER CXS SWITCHING SYSTEMS Intelepower DC UPS - CXS Range Designed For Switching The demands for quality power in switching applications are placing new demands

More information

PORTABLE TUBING PUMP MANUAL

PORTABLE TUBING PUMP MANUAL PORTABLE TUBING PUMP MANUAL TABLE OF CONTENTS SECTION PAGE SECTION PAGE 1.0 SAFETY INSTRUCTIONS................... 2 5.0 TUBING REPLACEMENT................... 1.1 1.2 General Safety Considerations.............

More information

Power Supplies PSS Series

Power Supplies PSS Series 8 January 2009 PSS Supplies Product Description Eaton s of power supplies is designed to work in a variety of applications, including the power supply to the IT. line of power control products. They also

More information

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS

nonstopower sdn bhd ( P) Power Management Instruments DC Battery Charger / Automation Type RELIABLE SOLUTIONS in POWER ELECTRONICS RELIABLE SOLUTIONS in POWER ELECTRONICS Power Management Instruments DC Battery Charger / Automation Type Distributed by : nonstopower sdn bhd (822490-P) no. 78 & 80, jalan rimbunan raya, laman rimbunan,

More information

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to RS-3 PRO RS-1007 PRO CAT IV Analog Clamp meter Series Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com RS-3 PRO RS-1007 PRO CAT IV Analog Clampmeter Series English

More information

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity

NetSure 701 Series DC Power System. DC Power for Business-Critical Continuity NetSure 701 Series DC Power System DC Power for Business-Critical Continuity Key Features n n High Efficiency approaching 97%, esure rectifiers reduce power consumption for lower operating costs Modular

More information

Current Switches and Transducers

Current Switches and Transducers Current Switches and Transducers Models CT-800,-805, -810, -815, -820, -825, -830 and CU-850, -855, -860, -865, -870, -875, -880, and -885 Easy to install... Small size, built-in mounting flanges, and

More information

CABINET REEL OPERATING INSTRUCTIONS

CABINET REEL OPERATING INSTRUCTIONS CABINET REEL OPERATING INSTRUCTIONS MODELS 15, 25, 40 & 60 SERIES RAPID-AIR CORPORATION 4601 KISHWAUKEE ST. ROCKFORD, IL 61109-2925 Phone: (815) 397-2578 Fax: (815) 398-3887 Web Site: www.rapidair.com

More information

SPECIFICATIONS LOW COST 2404R CHARGER

SPECIFICATIONS LOW COST 2404R CHARGER SPECIFICATIONS LOW COST 2404R CHARGER Totally Automatic Switch-Mode Battery Chargers "Suitable for Gel, Sealed & Wet Lead Acid Batteries" Summary: 24 Volts, 2 Amp Constant Current (Equivalent to 4A tapered

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

Z100A Clinical Centrifuge

Z100A Clinical Centrifuge Z100A Clinical Centrifuge User Manual C0100-A Rev 2 August 2016 About This Manual This manual is designed to assist you in the optimal usage of your Labnet Z100A Clinical Centrifuge. The manual is available

More information

Troubleshooting Bosch Proportional Valves

Troubleshooting Bosch Proportional Valves Troubleshooting Bosch Proportional Valves An Informative Webinar Developed by GPM Hydraulic Consulting, Inc. Instructed By Copyright, 2009 GPM Hydraulic Consulting, Inc. TABLE OF CONTENTS Bosch Valves

More information

Types VSA12, VSA12B, VSA16, VSA20, and VSA20A; three-phase; air-insulated; electronically controlled recloser

Types VSA12, VSA12B, VSA16, VSA20, and VSA20A; three-phase; air-insulated; electronically controlled recloser Reclosers Catalog Data CA280008EN Supersedes 280-45 July 2014 COOPER POWER SERIES Types VSA12, VSA12B, VSA16, VSA20, and ; three-phase; air-insulated; electronically controlled recloser VSA16 recloser

More information

Application. Battery. Public Grid GS HYBRID INVERTER

Application. Battery. Public Grid GS HYBRID INVERTER GS HYBRID SOLAR INVERTER Feed from Solar and Power, Grid backup, Build-in Transfer Switch / Solar Charger/ AC Charger, 500W~3kW, Pure Sine Wave Output GSH-15XX and GSH-30XX are the ideal solutions for

More information

PSU EN54-4 Power Supplies

PSU EN54-4 Power Supplies PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in

More information

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual 25500181 Rev. A0 415 Printed in U.S.A. Copyright 2015 Federal Signal Corporation Limited Warranty The Alerting and Notification Systems

More information

Unity Low Voltage Disconnect & Monitor

Unity Low Voltage Disconnect & Monitor Unity Low Voltage Disconnect & Monitor Installation/Operation Manual Model: ULM-100 Table of Contents Page Table of Contents Page 1.0 Overview 2 5.14 LVD Level Mapping 4 2.0 Materials Provided 2 5.2 Meter

More information

Super PWRgate PG40S Spring City Drive Waukesha, WI

Super PWRgate PG40S Spring City Drive Waukesha, WI Super PWRgate PG40S www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 sales@westmountainradio.com 2015, All rights reserved. All trademarks are the property of their respective

More information

5 MW 36 MW, kv. ACS6000 Medium Voltage Drive The modularity you require. The reliability you expect.

5 MW 36 MW, kv. ACS6000 Medium Voltage Drive The modularity you require. The reliability you expect. 5 MW 36 MW, 2.3 3.3 kv ACS6000 Medium Voltage Drive The modularity you require. The reliability you expect. The ACS6000 special purpose drive The ACS6000 medium voltage drive is part of ABB s special purpose

More information

SECURITRON POWER SUPPLIES MODELS: BPS-12-3, , 9 AND 15; BPS-24-2, 3, 4, 6 AND 10 OPERATION AND INSTALLATION INSTRUCTIONS

SECURITRON POWER SUPPLIES MODELS: BPS-12-3, , 9 AND 15; BPS-24-2, 3, 4, 6 AND 10 OPERATION AND INSTALLATION INSTRUCTIONS PN# 500-10300 Page 1 Rev. A.3, 9/03 SECURITRON POWER SUPPLIES MODELS: BPS-12-3, 4.5. 6, 9 AND 15; BPS-24-2, 3, 4, 6 AND 10 OPERATION AND INSTALLATION INSTRUCTIONS 1. DESCRIPTION These instructions cover

More information

EVS RP6020. Instruction Manual

EVS RP6020. Instruction Manual Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.

More information

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz. 103158 March 9, 2011 FOR INDOOR USE ONLY Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com

More information

Power Connect TM Series RX60

Power Connect TM Series RX60 Specification sheet Power Connect TM Series RX60 Features and benefits Robust product design and testing - The generator is designed to operate under extreme environmental conditions including cold weather

More information

ENGINEERED TO ORDER SOLUTIONS

ENGINEERED TO ORDER SOLUTIONS DM-Series ENGINEERED TO ORDER SOLUTIONS for Transformer Bushing, Winding Hot Spot and PD Monitoring Features & Benefits Advanced Analytics Flexible and Modular Hardware Platform Bushing Monitoring Optional

More information

RESISTIVITY MONITOR/CONTROLLERS

RESISTIVITY MONITOR/CONTROLLERS RESISTIVITY MONITOR/CONTROLLERS Installation Operation Maintenance User Manual for Models: 750, 752, 753, 762 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel: 1-760-438-2021 Fax: 1-800-869-7668 / 1-760-931-9189

More information

S25500 MAXI STIRRER OPERATION MANUAL AND PARTS LIST SERIES 849

S25500 MAXI STIRRER OPERATION MANUAL AND PARTS LIST SERIES 849 BARNSTEAD THERMOLYNE S25500 MAXI STIRRER OPERATION MANUAL AND PARTS LIST SERIES 849 Model S25535 Series 849 120 Volt 50/60 HZ Model S25530 Series 849 240 Volt 50/60 HZ Model S25530-26 Series 849 220-240

More information

400/230 Volt 60Hz UPS Power

400/230 Volt 60Hz UPS Power olt 60Hz Power Using ual Voltage standby generation and in one Nothing protects quite like Piller www.piller.com Contents 1 Abstract...3 2 Introduction...4 3 Alternative Power istribution...6 4 Integrating

More information

CHAPTER V RESIDENTIAL WIRING

CHAPTER V RESIDENTIAL WIRING CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this

More information

PRODUCTS: POWER SUPPLY

PRODUCTS: POWER SUPPLY PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER

More information

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1 Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG102909 iss 9 1 This drive is an isolated 4 Quadrant speed controller for shunt wound or permanent magnet motors. It utilises speed feedback

More information

315 kw 5000 kw, kv. ACS1000 Medium Voltage Drive The flexibility you require. The reliability you expect.

315 kw 5000 kw, kv. ACS1000 Medium Voltage Drive The flexibility you require. The reliability you expect. 315 kw 5000 kw, 2.3 4.16 kv ACS1000 Medium Voltage Drive The flexibility you require. The reliability you expect. The ACS1000 industrial drive The ACS1000 medium voltage drive is part of ABB s industrial

More information

GES-202TLP Traffic Light System Installation Manual

GES-202TLP Traffic Light System Installation Manual GES-202TLP Traffic Light System Installation Manual M1603_TLP_Installation_Manual V1.0 2012-06-12 IMPORTANT EMERGENCY SHUTDOWN PROCEDURE ON THE INSIDE OF REAR COVER NOTE: The instructions contained in

More information

SAFETY EQUIPMENT FOR RAILWAYS

SAFETY EQUIPMENT FOR RAILWAYS SAFETY EQUIPMENT FOR RAILWAYS Safety Equipment for Railways Our product range of safety equipment for railways is listed separately in Publication No. DS 501/E. The devices shown are compatible to systems

More information

Customer Substation Manual

Customer Substation Manual Customer Substation Manual Table of Contents Section Page 2 of 81 Description 0 Preface 010.00 General 010.10 Information Required for the Review of New Customer Substations 010.20 New Customer Substation

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Introduction A modular system of switchgear building blocks and cassettes provide untouchable

More information

SPECIFICATIONS SRF SuperchargerPlus

SPECIFICATIONS SRF SuperchargerPlus SPECIFICATIONS - 2412SRF Totally Automatic Switch-Mode Battery Chargers "Suitable for Gel, Sealed & Wet Lead Acid Batteries" Summary: 24 V, 6Amp Constant Current (equivalent to 12A tapered charger in charging

More information

Managing regeneration in RoboteQ controllers

Managing regeneration in RoboteQ controllers Managing regeneration in RoboteQ controllers Application Note Introduction Electrical motors are reversible machines; they can function as motors or as generators. A motor receives electrical power from

More information

Swing Gate Kits AUTOMATIC GATE KITS & ACCESSORIES SECURING GATES SINCE Control Cards. Accessories 2017 / Gate & Door Controls Catalogue

Swing Gate Kits AUTOMATIC GATE KITS & ACCESSORIES SECURING GATES SINCE Control Cards. Accessories 2017 / Gate & Door Controls Catalogue Sliding Gate Kits 3G Gate Opener Swing Gate Kits AUTOMATIC GATE KITS & ACCESSORIES SECURING GATES SINCE 1978 Control Cards Accessories 2017 / 2018 Gate & Door Controls Catalogue Gate and Door Technology

More information

Phase Modular Finally the benefits of Modular ups are for all

Phase Modular Finally the benefits of Modular ups are for all MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 The MUST 30/120 is an uninteruptible power supply, three phase input/ output, ranging from 15 kva to 120 kva

More information

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

Trane Liqui-Flo Addendum. Instruction Manual D2-3415

Trane Liqui-Flo Addendum. Instruction Manual D2-3415 Trane Liqui-Flo Addendum Instruction Manual D2-3415 The information in this manual is subject to change without notice. Throughout this manual, the following notes are used to alert you to safety considerations:!

More information

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data TC2000 TC2001 EUROTHERM ONTROLS Two phase thyristor power switches Product data TC2000 TC2001 Thyristor power switches Compact, two phase thyristor power switches for electrical heating applications from

More information

OPERATION MANUAL. Model TWP-2. Toll free customer support:

OPERATION MANUAL. Model TWP-2. Toll free customer support: OPERATION MANUAL TWE StudPro Pin Welder Lite Model TWP-2 Downey, CA 9459 Washburn Rd. Downey, CA 90242 Phone- 800.252.1919 Fax- 562.862.3022 Hayward, CA Phoenix, AZ 2391 American TRU WELD Ave. EQUIPMENT

More information

INSTRUCTION MANUAL FOR PC63 CAGE

INSTRUCTION MANUAL FOR PC63 CAGE INSTRUCTION MANUAL FOR PC63 CAGE CPN106833 ISSUE DATE: 15689-12/02 ECN/DATE 106 BRADROCK DRIVE DES PLAINES, IL. 60018 (847) 299-1188 FAX: (847) 299-3061 16816-6/05 INSTRUCTION DRAWING NUMBER: P25-LPC63-1

More information

Power Supplies. Series FLEX Power Supplies...P2 Technical Information & Dimensions (Online)...P5. ADEL Power Supplies

Power Supplies. Series FLEX Power Supplies...P2 Technical Information & Dimensions (Online)...P5. ADEL Power Supplies ower Supplies Series...2 Technical Information & Dimensions (Online)...5 ADEL ower Supplies 1 Flexible Switching ower Supplies Sprecher + Schuh is proud to bring you a Flexible ower Supply from the best

More information

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES TABLE OF CONTENTS 1. Introduction...1 1.1 The Alpha Redundant Control Unit (RCU)... 1 1.2 A Tour

More information

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS Hammond Power Solutions Inc. Page 1 of 1 ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS HPS Titan has been designed to operate in harsh environments/hazardous locations where dangerous gases, liquids,

More information

operation manual DUFT-TEC Solo (11//05)

operation manual DUFT-TEC Solo (11//05) operation manual DUFT-TEC Solo (11//05) page 1 of 8 DUFT-TEC Solo Table of contents Page 1. Function... 2 2. Technical data... 2 3. The fragrance pump... 2 3.1 Changing the hose set... 3 3.2 Dosing valve...

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Solar Combiner Solutions

Solar Combiner Solutions Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from

More information

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation

More information