MANUAL FOR ROTARY ACTUATORS ABSTRACT. Doc #SED-MAN-Rotary Actuators-002. Date: 11-Sep-2017
|
|
- Osborne Collins
- 6 years ago
- Views:
Transcription
1 ABSTRACT MANUAL FOR ROTARY This manual is intended as an information guide for operating SEDEMAC's Rotary Actuator. Doc #SED-MAN-Rotary Actuators-002 Date: 11-Sep-2017 ACTUATORS Product Manual Version #1.00
2 Copyright All rights reserved. No part of this publication may be reproduced, distributed or transmitted by any means (including photocopying or storing in any medium by electronic means or other) without the prior written permission of the copyright holder. Any reference to trademarked product names used within this publication is owned by their respective companies. SEDEMAC Mechatronics Pvt. Ltd. reserves the right to change the contents of this document without prior notice. For permission requests and applications to reproduce any part of this publication should be addressed to SEDEMAC Mechatronics Pvt. Ltd at below mentioned contact details. SEDEMAC Mechatronics Pvt. Ltd. C9-10, C Block, MIDC Bhosari Pune , INDIA Web Support: support@sedemac.com Website: Telephonic Support:
3 Safety Instructions General Instructions This document includes important instructions that should be followed during installation and maintenance of the Generator Set controller. For safety reasons, the manufacturer recommends that this equipment be installed and serviced by an Authorized Service personnel. Follow all applicable state and local electrical codes. Efficient and safe operation of the controller can be acquired only if the equipment is correctly operated and maintained. Many accidents arise due to ignorance or illiteracy towards the elemental rules of safety and precautions. The following safety notations found throughout this document indicate potentially hazardous conditions to the operator, service personnel or the equipment. Highlights an essential element of a procedure to ensure correctness Indicates a procedure or practice, which, if not strictly observed, could result in damage or destruction of equipment Indicates a procedure or practice, which could result in injuring personnel or loss of life, if not followed correctly Electrical safety Electric shock can cause severe personal injury or death. Ensure the generator set must be grounded before performing any installation or service. Generators produce high electrical voltages direct contact with it can cause fatal electrical shock. Prevent contact with terminals, bare wires, connections, etc., while the generator and related equipment are running. Do not tamper with interlocks. To handle the maximum electrical current, sizes of wire gauge used for electrical connections and wirings must be appropriate to which they will be subjected to. In operation safety Before installing Genset controller, ensure that all power voltage supplies are positively turned off at their source. Disconnect the generator s battery cables and remove panel fuse to prevent accidental start up. Disconnect the cable from the battery post, indicated by a NEGATIVE, NEG, or ( ) first. Reconnect the negative cable last. Failure to do so will result in hazardous and possibly fatal electrical shock. Remove electric power supply before removing controller or touching other electrical parts. Use extreme caution when working on electrical components. High voltage can cause injury or death. Use rubber insulative mats placed on dry wood platforms over floors that are metal or concrete when working near Generator set or other electrical equipment. Do not wear damp clothing (Particularly wet shoes) or allow skin surface to be damp when handling electrical equipment. Page 1 of 15
4 Do not operate any electrical device or wires while standing in water, while barefoot, or while hands or feet are wet. IT MAY RESULT IN SEVERE ELECTRICAL SHOCK. Do not wear jewellery. Jewellery can cause a short circuit within electrical contacts and cause shock or burning. In case of an accident caused by electric shock, immediately shut down the electrical power source. If this is not possible, try to release the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a nonconducting object, like, a rope or wooden stick, to release the victim from the live conductor. If the victim is unconscious, apply first aid and get immediate medical help. Page 2 of 15
5 List of Abbreviation This list contains the list of acronyms used in this document and it can be used to refer their respective description. This List Does not contain units of measure. Acronym AC ACK ALT AMF AUX BTS CHG CKT CT Ratio DC DG DIG IN ENG TEMP GCU Genset GND HMI HSD HWT LCD LED LLOP LOP LVL MCP MPU OV PID PWM RMS RPM R-Y-B SCP SMD TEMP USB UV Description Alternating Current Acknowledge Alternator Auto Mains Failure Auxiliary Base Transceiver Station Charging Circuit Current Transformer Ratio Direct Current Diesel Generator Digital Input Engine Temperature Genset Control Unit Generator Set Ground Human Machine Interface High Side Driver High Water Temperature Liquid Crystal Display Light Emitting Diode Low Lube Oil Pressure Lube Oil Pressure Level Manual Control Panel Magnetic Pickup Unit Over Voltage Proportional Integral Derivative Pulse Width Modulation Root Mean Square Revolutions Per Minute Red-Yellow-Blue Sensor Common Point State Machine Diagram Temperature Universal Serial Bus Under Voltage Page 3 of 15
6 Table of Contents 1 Introduction Key Highlights of the Product Product Variants Specifications Operation Installation Dimensions Mounting on Genset Pin Description Connection Details Troubleshooting Maintenance Notes Page 4 of 15
7 List of Figures Figure 1: Rotary actuators... 7 Figure 2: Small size actuator... 9 Figure 3: Medium size actuator Figure 4: Large size actuator Figure 5: Actuator assembly on genset Figure 6: Actuator connector pin out when viewed from the terminal insertion side Page 5 of 15
8 List of Tables Table 1: Environmental specifications... 8 Table 2: Technical specifications... 8 Table 3: Actuator variant specifications... 8 Table 4: Actuator wiring connection details Table 5: Troubleshooting Page 6 of 15
9 1 Introduction This document describes details of SEDEMAC s Rotary Actuators. SEDEMAC SEDEMAC B12 Rotary Actuators are designed and customized for precision motion control application on wide variety of diesel/gas/gasoline engines with mechanical fuel systems. Rotary Actuators are designed to operate along with SEDEMAC s genset controller (GCU) or B12 Electronic Control Unit (ECU) to perform electronic speed governing duty. It acts as air/fuel charge control to deliver the tight speed governing performance. Its robust architecture supported by a heavy-duty plastic enclosure offers high rigidity and strength to sustain against harsh environmental conditions and mechanical vibrations for engine mounted application. 1.1 Key Highlights of the Product Tough construction for engine mounted application Precision motion combined high torque density Control capability for both rotary and inline mechanical diesel injection pumps Supports both fuel stop lever control as well as throttle lever control for mechanical diesel injection pumps Low power consumption 1.2 Product Variants ACTZ02A (Standard Torque) SM ACTZ01A (Standard Torque with return spring) SM ACTZ06A (Medium Torque) SM ACTZ09A (Medium Torque with return spring) SM ACTZ11A (High Torque) SM ACTZ10A (High Torque with return spring) SM Figure 1: Rotary actuators Page 7 of 15
10 2 Specifications SEDEMAC SEDEMAC s Rotary Actuators are to be powered only by SEDEMAC s GCU or ECU. All SEDEMAC s GCUs and ECUs are 12V and 24V complaint. Table 1: Environmental specifications Operating/Storage Temperature -20 to 105 C as per IEC , 2 Vibration 5G in X, Y and Z axes for Hz as per IEC Humidity 0 to 95% RH as per IEC Ingress Protection IP56 as per IEC Table 2: Technical specifications Power Consumption Motion or 24V 150 deg travel Electrical Interface Construction Mounting Foot Print Dimension (For All Variants) 4 wire connector Encased in tough plastic casing made of Nylon 6 with 30% glass filled 78 mm x 40 mm 4 Number of holes mm Diameter each Table 3: Actuator variant specifications Types Standard Torque Medium Torque High Torque Output Torque 0.35 Nm 0.56 Nm 0.93 Nm Weight (With 870 g 1270 g 1600 g Return Spring) Dimensions 94 mm x 84 mm x 85 mm 94 mm x 84 mm x 121 mm 94 mm x 84 mm x 140 mm 3 Operation When connected to a proportional Rotary Actuator and supplied with a magnetic speed sensor signal, GCU or ECU controls the wide variety of engines. Rotary Actuators provides accurate and efficient speed control for governing. GCU or ECU reads the engine RPM through speed sensor and commands the Actuator to maintain the target governing RPM. Actuators operates the fuel stop/throttle lever via a linkage and controls the air/fuel charge. The actuator can vary on size based on the torque output it can provide. Some Actuators are designed with return spring mounted on them. This spring pulls back the fuel stop lever to stop upon loss of power as a safety feature. Page 8 of 15
11 4 Installation 4.1 Dimensions SEDEMAC uses three types of Rotary Actuators, small, medium and large depending on the different applications. Dimensions for these three types of actuators are given below. Figure 2: Small size actuator Page 9 of 15
12 Figure 3: Medium size actuator Page 10 of 15
13 4.2 Mounting on Genset Figure 4: Large size actuator This section gives the generic stepwise recommendation for installation of the SEDEMAC s Rotary Actuator on the genset. The required parts are as follows: Actuator Actuator mounting bracket Linkage* *Linkage transfers Actuator torque to operate the fuel stop/throttle lever to control engine RPM. The following is the stepwise procedure for assembling Rotary Actuator on genset. (Refer figure) Page 11 of 15
14 Assemble the Actuator-mounting bracket on the engine with help of fasteners. Fix the Actuator on the bracket with help of fasteners and bolts (M6 Bolts), size of which depends on the Actuator thickness. Place the wire connector cover of the Actuator on the left side, when looking from the Actuator s shaft side. 4.3 Pin Description Figure 5: Actuator assembly on genset Following figure provides the pin details of 4 wire Actuator connector. Figure 6: Actuator connector pin out when viewed from the terminal insertion side Page 12 of 15
15 4.4 Connection Details Following table provides the connection details while connecting Actuator with GCU or ECU. Table 4: Actuator wiring connection details SEDEMAC Actuator Connector Pin No. Description B12 ECU Pin No. GCU Terminal No. 1 ACT 1 (Orange coloured wire) ACT 4 (Blue coloured wire) ACT 2 (Red coloured wire) ACT 3 (Yellow coloured wire) Follow the recommended connection details for connecting Actuator with ECU or GCU. 5 Troubleshooting This section explains the common faults and their remedial actions. Table 5: Troubleshooting Sr. No. Faults Remedial Actions 1 Engine does not start after crank command 2 Engine cranks, but does not performing governing Check the Linkage for loose connections Check if actuator powered properly by GCU or ECU Check the Actuator for loose connections Check if Actuator wires connected correctly For further details, please refer to Manual for B12 Electronic Governor. This manual is available on SEDEMAC s website: 6 Maintenance For the smooth functioning of Actuator, following maintenance is required after 3 month s operations. Tightening all fasteners and bolts Greasing to spring, for the Actuators with spring Page 13 of 15
16 Notes Page 14 of 15
17 Disclaimer: Due to continuous development, the details provided in this document are subject to change without any prior notice. SEDEMAC Mechatronics Pvt Ltd Technical Centre C9-10, C Block, MIDC Bhosari Pune , India Manufacturing Plant G-1, MIDC, Phase-III Chakan Industrial Area, Nighoje Pune , India Manufacturing Plant Survey No. 64/5, Off Sinhagad Road Vadgaon Budruk, Narhe Pune , India Page 15 of 15
EG1299. Variable Speed Engine Controller for Telecom Backup Gensets SEDEMAC EG1299 HIGHLIGHTS
EG1299 Variable Speed Engine Controller for Telecom Backup Gensets HIGHLIGHTS Built-in electronic governor module Variable and fixed speed operation Configurable 0% droop with paralleling support RS485
More informationUSER MANUAL FOR GC500 GENSET CONTROLLER SEDEMAC ABSTRACT
ABSTRACT This manual is intended as an information guide for operating SEDEMAC's GC500 genset controller. USER MANUAL FOR Doc #SED-MAN-GC500-002 Date: 01-Aug-2016 GC500 GENSET CONTROLLER Product Manual
More informationMANUAL FOR GC2599 CONTROLLER ABSTRACT. This manual is intended as an information guide for operating SEDEMAC's GC2599 genset controller.
ABSTRACT This manual is intended as an information guide for operating SEDEMAC's GC2599 genset controller. MANUAL FOR GC2599 CONTROLLER Doc #SED-MAN-GC2599-002 Date: 28-Sep-2017 Product Manual Revision
More informationMonicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER
CHR-1285/2485 BATTERY CHARGER TEL:886-4-2238-0698 FAX:886-4-2238-0891 Web Site:http://www.monicon.com.tw E-mail:sales@monicon.com.tw Copyright 2007 Monicon Instruments Co., Ltd. All right reserved. Contents
More informationDSEULTRA DSE6000 Quick Start Guide Document Number
n DSEULTRA DSE6000 Quick Start Guide Document Number 057-102 Author : John Ruddock Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723 890099 Sales
More informationMULTIVOLTAGE PORTABLE BATTERY CHARGER MVM
_ M MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM User's MANUAL Code: MVM Version: 01-BF Date: OCT 2005 Page 1/10 _ 1. INTRODUCTION Before starting to use your Energic plus MVM battery charger, please take
More informationHGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology
HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951
More informationOwner's/Installation Manual
Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH
More informationDISCHARGER-ANALYZER BDX USER'S MANUAL
BATTERY DISCHARGER-ANALYZER BDX USER'S MANUAL OWM-BDX-261006 Page 1/10 1. INTRODUCTION Before starting to use your BDX battery discharger/analyzer, please take the time to read these instructions carefully.
More informationR-200A Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.
R-200A Digital Controller TECHNICAL MANUAL A new standard of reliability This manual should remain with the unit. IMPORTANT SAFETY INSTRUCTIONS Save These Instructions The manufacturer suggests that these
More informationAuto Mains Failure AMF Controller AE10113
Auto Mains Failure AMF Controller AE03 Auto Mains Failure DESCRIPTION AMF Controller AE03 is an Automatic Mains Failure controller, which activates the generator during power failure & vice versa. The
More informationPan and Tilt Head CDD2416-T
Pan and Tilt Head CDD2416-T Installation guide Before attempting to connect or operate this product, please read these instructions completely Williams Electronics Ltd www.w-e.co.uk Tel: +44 (0)2921 660
More informationMODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM
MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...
More informationOPERATING INSTRUCTIONS MCP-MT1
OPERATING INSTRUCTIONS MCP-MT1 MRM PROCOM Pvt Ltd ISO-9001-2008 certified organization Plot No. : 20-21, Industrial Estate, Sector - 59, Phase-II, Faridabad (Haryana) Ph.: 0129-4700400(10 Lines) Email:
More informationDrive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions
Drive Unit e-drive1 Installation instructions 04/2014 English translation of the original German installation instructions Contents Foreword... 3 Availability... 3 Structural features in the text... 3
More informationR-200A R-200C Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.
R-200A R-200C Digital Controller TECHNICAL MANUAL A new standard of reliability This manual should remain with the unit. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS The manufacturer suggests
More informationTechnical Documentation
Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that
More informationTechnical Manual. DLM Module. This manual should remain with the unit.
Technical Manual DLM Module This manual should remain with the unit. Safety Rules SAVE THESE INSTRUCTIONS! Read the following information carefully before attempting to install, operate or service this
More informationOPERATING INSTRUCTION: DGC-6D/6D1I
OPERATING INSTRUCTION: DGC-6D/6D1I GCB Auto Man Stop Fail - PROCOM Pvt Ltd MRM PROCOM Plot No. : 20-21, Industrial Estate, Sector - 59, Phase-II, Faridabad (Haryana) Ph.: 0129-4700400(10 Lines) Email:
More informationTT /17 INSTALLATION INSTRUCTIONS. Introduction. Required Tools and Equipment
TT-1701 2/17 INSTALLATION INSTRUCTIONS Original Issue Date: 2/17 Model: 15-60REOZK with Decision-Makerr 3000 Controllers Only Market: Industrial Subject: Electronic Governor Kit GM90661-KP1 Introduction
More informationHIGH VOLTAGE PROXIMITY DETECTOR
HIGH VOLTAGE PROXIMITY DETECTOR An ISO 9001:2008 Company Model 275 HP (Upto 275KV) / 500 HP (Upto 500KV) The 275HP / 500HP is a HIGH VOLTAGE proximity detector. 275HP has eight voltage detection settings
More informationINSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)
INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU) Model Number: 41756 (100 125Vac) 41757 (220 240Vac) Manufactured in the United Kingdom CONTENTS Chapter Page Specification 3 What the TAU does
More informationHGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic
HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic Smartgen Electronic Equipment Co., Ltd No.28 Jinsuo Road Zhengzhou Henan Province P.R.China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951/67992952
More informationOperator Manual. Transfer Switch. RSS100 and RSS Cummins Inc. All rights reserved. English
Operator Manual Transfer Switch RSS100 and RSS200 English 8-2007 962 0134 Table of Contents SECTION TITLE PAGE SAFETY PRECAUTIONS................................................... ii 1. INTRODUCTION.........................................................
More informationOwner s Manual. Contents GP-PWM-30-SQ GP-PWM-30-SQ
Owner s Manual Contents 1.0 Installation Overview... 2 2.0 Warnings... 2 3.0 Choosing a Location...3 4.0 Installation Instructions... 3 5.0 Operating Instructions...4 6.0 Frequently Asked Questions (FAQs)...6
More informationR-200A R-200B Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.
R-200A R-200B Digital Controller TECHNICAL MANUAL A new standard of reliability This manual should remain with the unit. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS The manufacturer suggests
More informationDisconnect Combiner Box Installation Manual
Disconnect Combiner Box Installation Manual SolarBOS, Inc. 310 Stealth Court Livermore CA 94551-9552 925-456-7744 ph. 925-456-7710 fax www.solarbos.com Copyright 2008 SolarBOS, Inc. All rights reserved.
More informationMAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -
MAKING MODERN LIVING POSSIBLE Quick Setup VLT FCM 300 Series Factory setting Motors type B14 & B34 mounting Reset (pushbutton) Start Jog Speed reference Fig. 1 - Reset to be closed short time for resetting
More informationHST -LS Interlocking device (Translation of Original Manual)
Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image
More informationSA-WP10-10M-VSF 24 v2
SA-WP10-10M-VSF 24 v2 Washer tank with submersible pump system Installation Manual Note: To ensure proper operation, please read this manual thoroughly before using the product and retain the information
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More informationCascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75
Cascade CD101 Auto-Start Controller Installation and Operations Manual 00-02-0594 2018-02-15 Sections 40 & 75 In order to consistently bring you the highest quality, full featured products, we reserve
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE4120 AUTO MAINS FAILURE MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel:
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE710 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44
More informationGEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1
GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter Version 1.1 Global Mainstream Dynamic Energy Technology Ltd. 1 Content Prelude... 4 1. Safety... 5 1.1 How to Use This Manual... 5 1.2 Safety Rules...
More informationR-100 Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.
R-100 Digital Controller TECHNICAL MANUAL A new standard of reliability This manual should remain with the unit. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS The manufacturer suggests that these
More informationOwner s Manual. Contents GP-PWM-10-SQ
Owner s Manual Contents 1.0 Installation Overview... 2 2.0 Warnings... 2 3.0 Choosing a Location... 3 4.0 Installation Instructions... 3 5.0 Operating Instructions... 4 6.0 Frequently Asked Questions (FAQs)...
More informationdv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING
dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.
More informationSDM72 Start on Demand Modules
Capricorn Controls DA04SDM72-2 Revised Design Page 1 of 6 SDM72 Start on Demand Modules Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products Application
More informationOwner's Manual 600 and 800 Amp RTS Automatic Transfer Switch
Owner's Manual 600 and 800 Amp RTS Automatic Transfer Switch Safety Rules SAVE THESE INSTRUCTIONS! Read the following information carefully before attempting to install, operate or service this equipment.
More informationInstallation and Operating Instructions. Solar System Controller ISC3020
Installation and Operating Instructions Solar System Controller ISC3020 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s of
More information362 Clamp Meter. Users Manual
362 Clamp Meter Users Manual PN 3622678 August 2010, Rev. 1, 4/13 2010, 2013 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names
More informationPrecision Motion Control
Precision Motion Control Military Rotary Actuator MRA 60 Product Overview This actuator is used to control the fins of a Missile. The affordable actuator robust design and use of special material in gearing,
More informationPRODUCT SERIES: DPG-2100
Service Information PRODUCT SERIES: DPG-2100 DYNA Programmable Governor for Isochronous Generators Calibration and Troubleshooting for DPG-2101, DPG-2102, DPG-2103, DPG-2104 DPG-2100 The DPG-2100 governors
More informationInstruction Manual. Q Series 2 Motor Control Modules - OEM
A382-21-880 Issue B Instruction Manual Q Series 2 Motor Control Modules - OEM Pump/ Q Motor Control Module Item Number pumping system Electrical supply 24 V d.c. control 24 V a.c. control QDP40 200-230
More informationElcometer 260. UV Pinhole Flashlight. Operating Instructions
Elcometer 260 English UV Pinhole Flashlight Operating Instructions English The product is Class B, Group 1 ISM equipment according to CISPR 11. Group 1 ISM product: A product in which there is intentionally
More informationBEFORE USING THE PRODUCT
HL-17015-5 BEFORE USING THE PRODUCT Thank you for purchasing an Oriental Motor product. Please read this BEFORE USING THE PRODUCT and the separate manual entitled OPERATING MANUAL thoroughly to ensure
More informationTurbocharger / VTR..0, VTR..1 Original assembly instructions English
Assembly Instructions Turbocharger / VTR..0, VTR..1 Original assembly instructions English This document is valid for the VTR..0/..1 series: VTR160, VTR200, VTR250, VTR320, VTR400 VTR161, VTR201, VTR251,
More informationRental Industry Safety Tester Safe Check 5s
Rental Industry Safety Tester Safe Check 5s Feb 2006 2006 Clare Instruments Inc. Issue 2.0 Firmware Version : 1.2a Limited Warranty & Limitation of Liability Clare Instruments Inc, guarantees this product
More information365 Detachable Jaw True-rms Clamp Meter
365 Detachable Jaw True-rms Clamp Meter Users Manual PN 3622684 August 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product
More informationEA / 10 / 50 Clamp Coil Adapter. Operation Manual. Version 1.00 April 2007 All product names are trademarks of their respective companies
EA002 2 / 10/ 50 TURN 1500A CLAMP COIL ADAPTER Ü EA002 2 / 10 / 50 Clamp Coil Adapter Operation Manual Version 1.00 April 2007 All product names are trademarks of their respective companies Guarantee and
More informationGDB..3..1A GLB..3..1A
4 624 OpenAir Air damper actuators Rotary version, three-position control, AC 24 V or AC 230 V GDB31A GLB31A Electric motor-driven actuators for three-position control, 5 / 10 Nm nominal torque, AC 24
More informationOPERATING INSTRUCTIONS ECON-M
OPERATING INSTRUCTIONS ECON-M INDEX 1.0 Introduction 2.0 Salient features, Protection & Supervision 3.0 Display/ Front Panel 4.0 Switches Description 5.0 LED Annunciations Description 6.0 Lamp Test 7.0
More informationTurbocharger / TPL-B Original assembly instructions English
Assembly Instructions Turbocharger / TPL-B Original assembly instructions English This document is valid for the TPL-B series: TPL85-B14/15/16, TPL91-B Purpose The assembly instructions explain how the
More informationANALOG CONTROL PANEL
ANALOG CONTROL PANEL 1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz. 3. Percent of Load: Displays percentage of load on the generator.
More informationMegohmmeter Test Probe
Megohmmeter Test Probe User Manual ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP Copyright Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All rights reserved. No part of this documentation may be reproduced
More informationPowers TM Controls EA 338 Electronic Actuator
Powers TM Controls Technical Instructions Document No. 155-136P25 EA 338-1 Description Features 24 Vac power supply. The s are used with floor mount linkage kits to operate dampers in HVAC installations.
More informationAlpha Performance Ignition Management Kit Fitting Instructions. Kit K Ford Zetec 1800cc 16 Valve & Ford Zetec 2000cc 16 Valve
Alpha Performance Ignition Management Kit Fitting Instructions Kit K97017 Ford Zetec 1800cc 16 Valve & Ford Zetec 2000cc 16 Valve For further information, please contact: Webcon UK Ltd Dolphin Road Middlesex
More informationTurbocharger / A100-L Original assembly instructions English
Assembly Instructions Turbocharger / A100-L Original assembly instructions English This document is valid for the A100-L series: A165-L, A170-L, A175-L, A180-L, A185-L, A190-L Purpose The assembly instructions
More informationSteering units by SKF. By-wire technology for improved vehicle efficiency and performance
Steering units by SKF By-wire technology for improved vehicle efficiency and performance Steer-by-wire for modern off-highway vehicles By-wire technology offers several advantages in the operation and
More informationNFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V
NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB4... NFX4...
More informationInstallation Instructions. APECS 0250 Kit Isuzu 4BG1-TRV Engine. Installation Instructions. Right-Hand Version. Manual 36561
Installation Instructions APECS 0250 Kit Isuzu 4BG1-TRV Engine Installation Instructions Right-Hand Version Manual 36561 WARNING Read this entire manual and all other publications pertaining to the work
More informationBasic Electrical Safety
Basic Electrical Safety Concerned About Electricity? How many sets of holiday lights do you plug into one extension cord? Do you still use your hot and sparking electric drill? Is your vacuum cleaner s
More informationALL POSITION VARIABLE SPEED TRAVEL CARRIAGE
ALL POSITION VARIABLE SPEED TRAVEL CARRIAGE MODEL GK-189-045 PARTS LIST & OPERATING INSTRUCTIONS Distributed by: Website: www.gullco.com GULLCO INTERNATIONAL LIMITED CANADA Phone: 905-953-4140 Fax: 905-953-4138
More informationGCU-10. Automatic Engine Control Unit Operators Manual
GCU-10 Automatic Engine Control Unit Operators Manual KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw Headquarters : No.3, Lane 201, Chien Fu St.,
More informationTESTER SET SOCKET & VOLTAGE
SOCKET & VOLTAGE TESTER SET 82384 These instructions accompanying the product are the original instructions. This document is part of the product, keep it for the life of the product passing it on to any
More informationKV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: High Voltage AC Test Set KV3-250 mk2 KV4-300 mk2 KV5-100 mk2 KV5-100T mk2 KV5-200 mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE720 AUTOSTART CONTROL MODULE OPERATING MANUAL http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North
More informationEDG6000 Electronic Digital Governor
INTRODUCTION GAC s digital governor is designed to regulate engine speed on diesel and gaseous fueled engines. When paired with a GAC actuator the EDG is a suitable upgrade for any mechanical governor
More informationICON 2 1. FEATURES AND CHARACTEIRICS
ICON 2 1. FEATURES AND CHARACTEIRICS High end Micro-controller(DSP) technology Wide range of auxiliary supply: 7V to 45Vdc. Low power Consumption : 200 ma @ 12 V DC. Alphanumeric 16X4 or 16X2 LCD display
More informationTable of Contents Foreword I. Product Introduction II. Notice For Safety III. Main Technical Parameters IV.
Foreword Thank you for choosing the LGK-ID IGBT Digital Air Plasma Cutter of Delixi (Hangzhou) Inverter Co., Ltd. Before use LGK-ID IGBT Digital Air Plasma Cutter, please carefully read this Manual to
More informationWorld Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual
World Leaders in Diesel Fuel Injection Test Equipment. IFT-c Injector Function Tester Controller Operating and Servicing Manual HL048 (EN) Issue 4, H1852, August 2011 HARTRIDGE LIMITED IFT-c Operating
More informationBATTERY CHARGER AR-D
BATTERY CHARGER AR-D USER'S MANUAL (THIS PAGE WAS INTENTIONALLY LEFT BLANK) TABLE OF CONTENTS...3...3...3...3...3...3...3 1. Introduction...4 RESPONSIBILITY DISCLAIMER...4 2. Safety instructions and warnings...5
More informationSBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes
Combiner Manual SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes User Manual U.S. Version 2.4 DOC-CBUG-01 i ii Combiner Manual Combiner Manual Copyright 2012 SMA America, LLC. All rights reserved.
More informationContactor Combiner Box Installation Manual
Contactor Combiner Box Installation Manual SolarBOS, Inc. 310 Stealth Court Livermore CA 94551-9552 925-456-7744 ph. 925-456-7710 fax www.solarbos.com Copyright 2008 SolarBOS, Inc. All rights reserved.
More informationAutoranging Industrial Multimeter
Owner's Manual Autoranging Industrial Multimeter Model No. 82005 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation
More informationINSTRUCTION MANUAL CRS Combined insulation bushing
INSTRUCTION MANUAL CRS Combined insulation bushing 5COH020200 CRS REV03 2 TABLE OF CONTENTS 1 SAFETY... 5 1.1 SAFETY INSTRUCTION... 5 1.2 SPECIFIED APPLICATION... 5 1.3 SAFETY NOTES ON THE EQUIPMENT OPERATION...
More informationTable of Contents Title Page No.
Table of Contents Title Page No. INTRODUCTION 1 SAFETY PRECAUTIONS / WARNINGS 2 CONTROLS AND INDICATORS 4 PREPARATION AND CAUTION BEFORE USE 5 TESTING PROCEDURES 6 A. AC/DC VOLTAGE MEASUREMENT 6 B. RESISTANCE
More informationWELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04
WELDING INVERTER PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL PEGAS 160-200 E Smart Manual EN 04 2/12 CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL DATA...
More informationDALI 650mA LED Driver
Installation Guide DGLC650C18DD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095
More informationDeclaration of Conformity
Declaration of Conformity We, Manufacturer: Spartanics Ltd. 3605 Edison Place Rolling Meadows, Illinois 60008 Phone: 847-394-5700 Fax: 847-394-0409 USA ENGLISH declare under our sole responsibility that
More informationInstallation Instructions for Load Management Kit A051C329
Instruction Sheet 12-2014 Installation Instructions for Load Management Kit A051C329 1 Introduction The information contained within is based on information available at the time of going to print. In
More information362 Clamp Meter. Users Manual
362 Clamp Meter Users Manual PN 3622678 August 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks
More informationSD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,
4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en
More informationMount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)
EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp
More informationTorque min. 35 in-lb, for control of air dampers
LF-SR (-S) US Proportional Damper Actuator, Spring Return Fail-Safe, V for to VDC, or to ma Control Signal. Output Signal of to VDC for Position Indication. Torque min. 35 in-lb, for control of air dampers
More informationFLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE
FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information
More informationR-200A Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.
R-200A Digital Controller TECHNICAL MANUAL A new standard of reliability This manual should remain with the unit. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS The manufacturer suggests that these
More informationINVERTER FOR DC CRANE CABIN AIR CONDITIONING UNIT 3KW VERSION
Page 1 of 11 Power Assembly Doc. DOC-SE-001 Ver 5.9 Writer: LD INVERTER FOR DC CRANE CABIN AIR CONDITIONING UNIT 3KW VERSION In many locations, having air conditioning in a crane cabin is very important
More informationInstallation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206
Instruction Sheet 7-2013 Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206 1 Introduction The information contained within is based on information available at the time of going
More informationOwner's Manual. LTS Load Shed Switch. This manual should remain with the unit.
Owner's Manual LTS Load Shed Switch This manual should remain with the unit. Table of Contents SAFETY RULES SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed
More informationBP- A Series Switch-Mode 3 Stage Battery Charger User s Manual
BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual Table of Contents 1. Important Safety Information. 1 1-1 General Safety Precautions 1 1-2 Battery Precautions..... 2 2. Features... 3 2-1
More informationOwner's Manual. LTS Load Shed Switch. This manual should remain with the unit.
Owner's Manual LTS Load Shed Switch This manual should remain with the unit. Table of Contents Safety Rules... Inside Front Cover General Information... 2 1.1 Introduction... 2 1.2 Equipment Description...
More informationMinimum 27 in-lb Torque
LU Series Actuator Minimum 27 in-lb Torque For damper areas up to 6.8 sq-ft* Actuators in bold have BDCM LU Series - At A Glance LUB(X)24-3 (p. 351) LUX120-3 (p. 353) LUB(X)24-SR (p. 355) LUX120-SR (p.
More informationMETROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide
METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide Copyright 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced,
More informationPower consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3
SRFA Rotary actuator with emergency function for ball valves Torque 20Nm Nominal voltage AC 24...240V / DC 24...125V Control: Open/Close SRFA: Deenergised NC Technical data Electrical data Nominal voltage
More informationIndustrial Controls. Load Feeders and Motor Starters. SIRIUS MCU Motor Starters. Gerätehandbuch. Answers for industry.
Industrial Controls Load Feeders and Motor Starters SIRIUS MCU Motor Starters Gerätehandbuch Manual Edition 08/2014 Answers for industry. SIRIUS Manual Safety notes 1 Mechanical installation 2 Electrical
More informationTechnical Manual Electrical Power Supply System T4002
Technical Manual Electrical Power Supply System T400 MOZELT GmbH & Co. KG Please observe the following safety information and recommendations before start-up! Copyright: MOZELT GmbH & Co. KG, D-4769 Duisburg
More informationADJUSTABLE ROTARY SCRAPER TOOL SCR USER S GUIDE
ADJUSTABLE ROTARY SCRAPER TOOL SCR-090-225 USER S GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the
More informationUTS 696 Under Tailgate Spreader Owner s Manual
July 15, 2004 Lit. No. 94838 UTS 696 Under Tailgate Spreader Owner s Manual Read this manual before installing or operating the spreader. This manual is for UTS 696 Under Tailgate Spreaders with serial
More information