Modbus Register Map:Galaxy VM (3: kVA 400/480V)
|
|
- Moris Darrell Shields
- 6 years ago
- Views:
Transcription
1 Modbus Register Map:Galaxy VM (3: kVA 400/480V) Part number: Notes:. 6-bit registers are transmitted MSB first (i.e. big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least significant word in n+ (i.e. big-endian). 3. Function codes 3 and 4 are supported 4. Modbus serial RTU and Modbus over TCP is supported. 5. Signed numbers are twos-compliment 6. Status bits are atomic within a single Modbus register. User should not look for consistency across multiple registers, only within a single register. 7. For ASCII strings less than the maximum length, the unused characters are filled with nulls. 8. Single-register reads of reserved or undefined registers will return an error. Block reads which begin with a valid register will not return an error but will return zeros for undefined registers. 9. Strings are two characters per register, first character in high-order byte, second character in low-order byte. Printable ASCII only. 0. Bit #0 is least significant bit.. Data Type column: "INT6"=signed 6-bit integer, "UINT6" = unsigned 6-bit integer, "INT32" = signed 32-bit integer, "UINT32" = unsigned 32-bit integer, "ENUM" is a UINT6 value which maps to a defined list of states, "ASCII" = the printable ASCII subset from 0x20-0x7E. BOOLEAN= a single bit, 0 or. 2. " Register Address" = 0 (the column heading used in this table) is equivalent to "Register 4000" in Modicon terminology, which is address zero when transmitted over the wire. For detailed modbus configuration settings, please refer to the Display or AP9635 User s Guide. Modicon Standard Status Data x000 UPS Status 0 UPS operation mode - Battery BOOLEAN =UPS operation mode - Battery Battery is below minimum acceptable runtime BOOLEAN =Battery is below minimum acceptable runtime 2 Bypass BOOLEAN =UPS is in Bypass 3 UPS operation mode - Battery Test BOOLEAN =UPS operation mode - Battery Test 9 Battery fault BOOLEAN =Battery fault 3 Informational alarm present BOOLEAN =Informational alarm present 4 Warning alarm present BOOLEAN =Warning alarm present 5 Critical alarm present BOOLEAN =Critical alarm present x Alarm Register 0 Lost local network management interface - to - UPS communication BOOLEAN =Lost local network management interface - to - UPS communication Display communication is lost BOOLEAN =Main Controller is unable to communicate with the display 2 Parallel communication error on PBUS cable BOOLEAN =Parallel communication error on PBUS cable 3 Parallel communication error on PBUS cable 2 BOOLEAN =Parallel communication error on PBUS cable 2 2 Communication cable termination fault BOOLEAN =Communication cable termination fault 3 General parallel system error BOOLEAN =General parallel system error 4 Lost parallel redundancy BOOLEAN =Lost parallel redundancy x Alarm Register
2 UPS operation mode - Requested Static Bypass BOOLEAN =UPS operation mode - Requested Static Bypass 2 UPS operation mode - Forced Static Bypass BOOLEAN =UPS operation mode - Forced Static Bypass 3 UPS operation mode - Maintenance Bypass BOOLEAN =UPS operation mode - Maintenance Bypass 4 Started a self-test BOOLEAN 5 UPS operation mode - Off BOOLEAN =UPS operation mode - Off 6 UPS operation mode - Initialize BOOLEAN =UPS operation mode - Initialize Input phase sequence error BOOLEAN =Input phase sequence error 2 Input frequency fault BOOLEAN =Input frequency fault 3 Input voltage error BOOLEAN =Input voltage is out of range 4 Selftest - Failed BOOLEAN =Self test has failed x Alarm Register Reserved BOOLEAN 3 Bypass frequency fault BOOLEAN =Bypass frequency fault 4 Bypass phase sequence error BOOLEAN =Bypass phase sequence error 8 Overload on UPS BOOLEAN =Overload on UPS 9 Overload on Static bypass switch BOOLEAN =Overload on Static bypass switch 0 Ambient temperature out of range BOOLEAN =Ambient temperature out of range EPO Switch Activated BOOLEAN =EPO Switch activated 2 Ground fault detected BOOLEAN =Ground fault detected 4 Bypass voltage error BOOLEAN =Bypass input voltage is out of range x Alarm Register 0 System locked in bypass operation BOOLEAN =System locked in bypass operation Batteries are discharging BOOLEAN =Batteries are discharging 5 Charge power is reduced BOOLEAN =Charge power is reduced 2 Battery condition is weak BOOLEAN =Battery condition is weak 3 Battery condition is poor BOOLEAN =Battery condition is poor x RESERVED x Alarm Register Reserved BOOLEAN 3 Ambient temperature high BOOLEAN = Ambient temperature is high 4 Overload on UPS due to high ambient temperature BOOLEAN = Overload on UPS due to high ambient temperature 5 Output frequency fault BOOLEAN =Output frequency fault 6 Output voltage error BOOLEAN =Output voltage is outside its defined limits 2
3 x RESERVED x Alarm Register Reserved BOOLEAN 9 Unit Unit Breaker (UIB) open BOOLEAN =Unit Unit Breaker (UIB) open 0 Unit Ouput Breaker (UOB) open BOOLEAN =Unit Ouput Breaker (UOB) open Maintenance Bypass Breaker (MBB) closed BOOLEAN =Maintenance Bypass Breaker (MBB) closed 2 System Isolation Breaker (SIB) open BOOLEAN =System Isolation Breaker (SIB) open 3 Static Switch Input Breaker (SSIB) open BOOLEAN =Static Switch Input Breaker (SSIB) open 400 0x000A 0 Alarm Register Reserved BOOLEAN 8 Static bypass switch fault BOOLEAN 9 Static bypass switch warning BOOLEAN =Static bypass switch has a critical fault that prevents it from operating =Static bypass switch has an error with severity level warning x000B RESERVED x000E 4 Alarm Register BOOLEAN Reserved BOOLEAN 3 High Battery Temperature Level BOOLEAN =Battery temperature above alarm setting 4 Low Battery Temperature Level BOOLEAN =Battery temperature below alarm setting 3
4 Battery breaker BB open BOOLEAN =Battery breaker BB open 2 Battery breaker BB2 open BOOLEAN =Battery breaker BB2 open x000F 5 RESERVED x000 6 Alarm Register 0 UPS operation mode - Static bypass standby BOOLEAN =UPS operation mode - Static bypass standby UPS operation mode - Inverter standby BOOLEAN =UPS operation mode - Inverter standby 4 General UPS settings error BOOLEAN =General UPS settings error 5 UPS configuration error BOOLEAN =UPS has general configuration error 6 Synchronization error BOOLEAN =Synchronization error-system is free running =UPS has one or more faulty fans. Fan redundancy is lost. 7 Fan fault BOOLEAN 8 Inverter is Off due to a request by the user BOOLEAN = Inverter is Off due to a request by the user 9 Restricted air flow BOOLEAN =Restricted air flow 0 Surveillance fault BOOLEAN =Surveillance fault exists in UPS Charger status BOOLEAN =Faulty 2 Inverter status BOOLEAN =Faulty 3 PFC status BOOLEAN =Faulty 4 Battery status BOOLEAN =Faulty x00 7 Alarm Register 0 Technical check recommended BOOLEAN =Technical check recommended Start-up recommended BOOLEAN = Secure start-up recommended 2 Warranty expiring soon BOOLEAN =Warranty expiring soon 4 Air filter check recommened BOOLEAN =Air filter check recommened x002 8 RESERVED x003 9 Alarm Register =Warning alarm in Prallel UPS Reserved BOOLEAN =Warning alarm in Prallel UPS 2 =Warning alarm in Prallel UPS 3 =Warning alarm in Prallel UPS 4 =Warning alarm in Prallel UPS 5 5 Not enough UPS ready to turn on inverter BOOLEAN =Not enough UPS ready to turn on inverter 6 Parallel UPS not present BOOLEAN =Parallel UPS not present 7 Parallel UPS 2 not present BOOLEAN =Parallel UPS 2 not present 8 Parallel UPS 3 not present BOOLEAN =Parallel UPS 3 not present 9 Parallel UPS 4 not present BOOLEAN =Parallel UPS 4 not present 0 Parallel UPS 5 not present BOOLEAN =Parallel UPS 5 not present Parallel mixed operation mode BOOLEAN =Parallel mixed operation mode 4
5 4002 0x RESERVED x005 2 Alarm Register 0 System operation mode - Off BOOLEAN = System operation mode - Off System operation mode - Forced static bypass BOOLEAN = System operation mode - Forced static bypass 2 System operation mode - Requested static bypass BOOLEAN = System operation mode - Requested static bypass 3 System operation mode - Maintenance bypass BOOLEAN = System operation mode - Maintenance bypass x Alarm Register 0 Input missing phase error BOOLEAN =Input is missing a phase Bypass missing phase error BOOLEAN =Bypass input is missing a phase 2 External sync voltage error BOOLEAN =External sync voltage is out of range 3 External sync phase sequence error BOOLEAN =The phase rotation on external sync is wrong 4 External sync frequency fault BOOLEAN =External sync frequency is out of range 5 External sync missing phase error BOOLEAN =External sync is missing a phase 8 Display firmware incompatibility detected BOOLEAN =Display firmware incompatibility detected 9 NMC firmware incompatibility detected BOOLEAN =NMC firmware incompatibility detected 0 NMC 2 firmware incompatibility detected BOOLEAN =NMC 2 firmware incompatibility detected 2 Inverter output is not in phase with bypass input BOOLEAN =Inverter output is not in phase with bypass input x Alarm Register 0 Modular battery cabinet fault BOOLEAN =Modular battery cabinet fault Modular battery cabinet 2 fault BOOLEAN =Modular battery cabinet 2 fault 2 Modular battery cabinet 3 fault BOOLEAN =Modular battery cabinet 3 fault 3 Modular battery cabinet 4 fault BOOLEAN =Modular battery cabinet 4 fault 4 Modular battery cabinet 5 fault BOOLEAN =Modular battery cabinet 5 fault 5 Modular battery cabinet 6 fault BOOLEAN =Modular battery cabinet 6 fault 6 Modular battery cabinet 7 fault BOOLEAN =Modular battery cabinet 7 fault 7 Modular battery cabinet 8 fault BOOLEAN =Modular battery cabinet 8 fault x Alarm Register 0 Modular battery cabinet breaker open BOOLEAN =Modular battery cabinet breaker open Modular battery cabinet breaker 2 open BOOLEAN =Modular battery cabinet breaker 2 open 2 Modular battery cabinet 2 breaker open BOOLEAN =Modular battery cabinet 2 breaker open 3 Modular battery cabinet 2 breaker 2 open BOOLEAN =Modular battery cabinet 2 breaker 2 open 4 Modular battery cabinet 3 breaker open BOOLEAN =Modular battery cabinet 3 breaker open 5 Modular battery cabinet 3 breaker 2 open BOOLEAN =Modular battery cabinet 3 breaker 2 open 5
6 6 Modular battery cabinet 4 breaker open BOOLEAN =Modular battery cabinet 4 breaker open 7 Modular battery cabinet 4 breaker 2 open BOOLEAN =Modular battery cabinet 4 breaker 2 open 8 Modular battery cabinet 5 breaker open BOOLEAN =Modular battery cabinet 5 breaker open 9 Modular battery cabinet 5 breaker 2 open BOOLEAN =Modular battery cabinet 5 breaker 2 open 0 Modular battery cabinet 6 breaker open BOOLEAN =Modular battery cabinet 6 breaker open Modular battery cabinet 6 breaker 2 open BOOLEAN =Modular battery cabinet 6 breaker 2 open 2 Modular battery cabinet 7 breaker open BOOLEAN =Modular battery cabinet 7 breaker open 3 Modular battery cabinet 7 breaker 2 open BOOLEAN =Modular battery cabinet 7 breaker 2 open 4 Modular battery cabinet 8 breaker open BOOLEAN =Modular battery cabinet 8 breaker open 5 Modular battery cabinet 8 breaker 2 open BOOLEAN =Modular battery cabinet 8 breaker 2 open Static Data x Display/NMC Model Number 9 ASCII x Display/NMC Serial Number 8 ASCII 444 0x0 43 Display/NMC Firmware Revision APP 9 ASCII x0A 422 Display/NMC Hardware Revision 9 ASCII x Display/NMC Date of Manufacture 6 ASCII x RESERVED x UPS Serial Number 6 ASCII x UPS Firmware Version 2 ASCII x Product Name 40 ASCII Dynamic Data x RESERVED x Runtime remaining 2 UINT32 Seconds x Estimated charge time 2 UINT32 Seconds x Estimated charge % UINT6 % x RESERVED x0F 4367 Battery Temperature (for classic battery solution) UINT6 C x Charger Mode 0 Float Charging BOOLEAN =Charger mode is float charging Boost Charging BOOLEAN =Charger mode is boost charging 5 Equalization Charging BOOLEAN =Charger mode is eqalization charging 6 Not Charging BOOLEAN =Charger mode is Off 7 Test In Progress BOOLEAN =Test is in progress 8 Cyclic Charging BOOLEAN =Charge mode is cyclic charging x 4369 Battery Power INT6 0, 0 kw x RESERVED x3 437 Battery Voltage UINT6 0, 0 Vdc x Battery Current INT6 0, 0 amps x Modular Battery cabinet temperature UINT6 C x Modular Battery cabinet 2 temperature UINT6 C x Modular Battery cabinet 3 temperature UINT6 C x Modular Battery cabinet 4 temperature UINT6 C x Modular Battery cabinet 5 temperature UINT6 C xA 4378 Modular Battery cabinet 6 temperature UINT6 C xB 4379 Modular Battery cabinet 7 temperature UINT6 C xC 4380 Modular Battery cabinet 8 temperature UINT6 C x Frequency (input) UINT6 0, 0 Hz x Voltage L-2 (input) UINT6 Vrms 446 0x Voltage L2-3 (input) UINT6 Vrms x Voltage L3- (input) UINT6 Vrms 6
7 4463 0x Current L (input) UINT6 amps x Current L2 (input) UINT6 amps x Current L3 (input) UINT6 amps x Active power L (input) UINT6 kw x Active power L2 (input) UINT6 kw x Active power L3 (input) UINT6 kw x20A 468 Apparent power L (input) UINT6 kva x20B 469 Apparent power L2 (input) UINT6 kva x20C 4620 Apparent power L3 (input) UINT6 kva x20D 462 Total active power (input) UINT6 kw x20E 4622 Total apparent power (input) UINT6 kva x20F 4623 Voltage L-N (input) UINT6 Volts x Voltage L2-N (input) UINT6 Volts x Voltage L3-N (input) UINT6 Volts x Maximum RMS Current L (input) 2 UINT6 amps x Maximum RMS Current L2 (input) 2 UINT6 amps x Maximum RMS Current L3 (input) 2 UINT6 amps x Power factor L (input) UINT6 0, 0 Unitless x Power factor L2 (input) UINT6 0, 0 Unitless x2A 4634 Power factor L3 (input) UINT6 0, 0 Unitless x Frequency (bypass) UINT6 0, 0 Hz x Voltage L-2 (bypass) UINT6 Vrms x Voltage L2-3 (bypass) UINT6 Vrms x Voltage L3- (bypass) UINT6 Vrms x Current L (bypass) UINT6 amps x Current L2 (bypass) UINT6 amps x Current L3 (bypass) UINT6 amps x Active power L (bypass) UINT6 kw x Active power L2 (bypass) UINT6 kw x Active power L3 (bypass) UINT6 kw x30A 4874 Apparent power L (bypass) UINT6 kva x30B 4875 Apparent power L2 (bypass) UINT6 kva x30C 4876 Apparent power L3 (bypass) UINT6 kva x30D 4877 Total active power (bypass) UINT6 kw x30E 4878 Total apparent power (bypass) UINT6 kva x30F 4879 Voltage L-N (bypass) UINT6 Volts x Voltage L2-N (bypass) UINT6 Volts x3 488 Voltage L3-N (bypass) UINT6 Volts x Maximum RMS Current L (bypass) 2 UINT6 amps x Maximum RMS Current L2 (bypass) 2 UINT6 amps x Maximum RMS Current L3 (bypass) 2 UINT6 amps x Power factor L (bypass) UINT6 0, 0 Unitless x Power factor L2 (bypass) UINT6 0, 0 Unitless x3A 4890 Power factor L3 (bypass) UINT6 0, 0 Unitless 452 0x UPS Power Rating UINT6 kva x40 52 Frequency (output) UINT6 0, 0 Hz x Voltage L-2 (output) UINT6 Vrms x Voltage L2-3 (output) UINT6 Vrms x Voltage L3- (output) UINT6 Vrms x Current L (output) UINT6 amps x Current L2 (output) UINT6 amps x Current L3 (output) UINT6 amps x Maximum RMS current L (output) 2 UINT32 amps 453 0x40A 530 Maximum RMS current L2 (output) 2 UINT32 amps x40C 532 Maximum RMS current L3 (output) 2 UINT32 amps x40E 534 Active power L (output) UINT6 kw x40F 535 Active power L2 (output) UINT6 kw x Active power L3 (output) UINT6 kw x4 537 Apparent power L (output) UINT6 kva x Apparent power L2 (output) UINT6 kva x Apparent power L3 (output) UINT6 kva 454 0x RESERVED 3 7
8 4544 0x Total active power (output) UINT6 kw x Total apparent power (output) UINT6 kva x Total Output Percent load UINT6 0, 0 % x4A 546 Power factor L (output) UINT6 0, 0 power factor x4B 547 Power factor L2 (output) UINT6 0, 0 power factor x4C 548 Power factor L3 (output) UINT6 0, 0 power factor x4D 549 Current crest factor L (output) UINT6 0, 0 crest factor 455 0x4E 550 Current crest factor L2 (output) UINT6 0, 0 crest factor x4F 55 Current crest factor L3 (output) UINT6 0, 0 crest factor x Voltage L-N (output) UINT6 Volts x Voltage L2-N (output) UINT6 Volts x Voltage L3-N (output) UINT6 Volts x Neutral current (output) UINT6 amps x Current THD L (output) UINT6 0, 0 % x Current THD L2 (output) UINT6 0, 0 % x Current THD L3 (output) UINT6 0, 0 % x RESERVED x Switch gear status 0 Unit Input Breaker (UIB) BOOLEAN Unit Output Breaker (UOB) BOOLEAN 2 (Maintenance Bypass Breaker (MBB) BOOLEAN 3 System Isolation Breaker (SIB) BOOLEAN 4 Static Switch Input Breaker (SSIB) BOOLEAN 5 Battery Breaker (for classic battery solution) BOOLEAN 6 Battery Breaker 2 (for classic battery solution) BOOLEAN Bit mask For each bit, 0 = open, =closed 0 = Reserved = Normal operation 2 = Battery Operation 3 = Battery Test 4 = Requested Static Bypass 5 = Forced Static Bypass 6 = Maintenance Bypass 7 = Off x UPS Operation Mode ENUM 8 = Emergency Static Bypass 9 = Static Bypass Standby 0 = Inverter Standby = Power Saving Mode 2 = SPoT Mode 3 = ECO Mode 4 = ECOnversion x Number of Active Alarms UINT6 Number of active alarms in the system x Highest alarm severity UINT6 0 = none = informational 2 = warning 3 = critical 8
9 x System Mode ENUM = Inverter 2 = Requested Static Bypass 3 = Forced Static Bypass 4 = Off 5 = Reserved 6 = Maintenance Bypass 7 = ECO Mode 8 = ECOnversion x RESERVED x NMC/UPS Time 4 ASCII hh:mm:ss format x50D 5389 NMC/UPS Date 5 ASCII mm/dd/yyyy format x Input kwh 2 UINT32 kwh x Output kwh 2 UINT32 kwh x Current L (parallel system mains input) UINT6 amps x Current L2 (parallel system mains input) UINT6 amps x Current L3 (parallel system mains input) UINT6 amps x Current L (parallel system bypass input) UINT6 amps x Current L2 (parallel system bypass input) UINT6 amps x Current L3 (parallel system bypass input) UINT6 amps x Current L (parallel system output) UINT6 amps x Current L2 (parallel system output) UINT6 amps x Current L3 (parallel system output) UINT6 amps x Total apparent power (parallel system output) UINT6 kva 464 0x90A 640 Total Percent load (parallel system) UINT6 0, 0 % Configuration Data x RESERVED x Number of Battery Modules UINT x Low Battery Alarm Threshold UINT6 Seconds 0=VRLA x Battery Type ENUM =Open Cell 0=None x Battery Solution ENUM =Classic 2=Modular 3=Unknown 0=No x Deep Discharge Allowed ENUM =Yes x Total Battery Capacity UINT6 Ah x Nominal Output Voltage x Transfer to Static Bypass Disable x Flywheel Present x Automatic Battery Disconnect x High Efficiency Mode END OF MAP ENUM ENUM ENUM ENUM ENUM 0=380V =400V 2=45V 3=480V 0=Disable =Enable 0=No =Yes 0=No =Yes 0=Disable =ECO mode 2=ECOnversion 9
Powerware Master Modbus
Powerware Master Modbus Map 164201391 Rev D This document describes the format of the data contained in the Modbus messages. Not all registers apply to all UPS modules. Please consult the individual UPS
More informationWeb/SNMP Management Card Event Support Chart
Web/SNMP Management Card Event Support Chart 0x0001 System: Coldstart. 0x0002 System: Warmstart. 0x0003 System: SNMP configuration change. System: Detected an unauthorized user attempting to access the
More informationDISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm
DISCRETE INPUTS SUGGESTED LENGTH: 39 NOTE: YOUR UPS MAY NOT SUPPORT ALL FIELDS Description Address Offset Standard Address Value 0 Value 1 Alarm Temperature 0x0100 0257 10257 OK Over Temperature Alarm
More informationPowerValue 11/31 T kva
Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power
More informationPowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter
PowerCommand ModLon II Gateway ModBus LON Converter Description The PowerCommand ModLon II Gateway is used to interface PowerCommand networks to devices and systems that communicate in Modbus communication
More informationGalaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.
Galaxy VM From 160 kva to 1000 kva Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that seamlessly integrates
More informationEasy UPS 3S. Operation 07/
Easy UPS 3S 10 40 kva Operation 07/2018 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to in this
More information#+, -".#,/.0/ &%( 8('4),54, 0/ 690/:,!.5/!./4,!! 0."+;,!<!!.9.,/ >0/)! 4,. +. A),, 9 0/:,!. 5/,?" 5?? /5.'0/.>.5,/..5 B,,+
!"#$%!"#! &' #+, -".#,/.0/ 1-20/*3)**% (-4'../".+/5/!/46&4&// 5',/%/.)*)%74 &%( 8('4),54, 0/ 690/:,!.5/!./4,!! 0."+;,!
More informationPOWER kva
+44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply SGSE_010-040_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91
More informationPOWER kva
TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power
More informationTECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)
TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5
More informationModbus Communications
Modbus Communications For Models PVI 14- Revision B 2017, Yaskawa - Solectria Solar Table of Contents 1. Yaskawa - Solectria Solar PVI 14- Modbus... 3 1.1 Introduction... 3 1.2 Abbreviations... 3 1.3 Modbus
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply SGSE_400-500_S3_UPS_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33U Series / 10 20 30 40 50 60 kva 208 VAC UL Series 1 Date of issue: 11/05/2008 LPS33U_030-040_S1 GE_01
More informationTECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)
TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power
More informationGalaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products
From 160 kva to 1000 kva Three-phase power protection 2 3 trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that seamlessly integrates into the
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TM SG Series 200-250 - 300 PurePulse CE S3 TM SG Series 160 PurePulse CE S3 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)
More informationPOWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)
TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)
More informationTechnical Data Sheets
GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01
More informationTECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)
TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5
More informationUPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES
UPS UPS MODULAR THREE-PHASE from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES Modular and upgradable with power from 10 to 60kVA in compact structures with a reduced
More informationGalaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection
Galaxy VM From 160 kva to 1000 kva, 160 kva or 200 kva modular approach Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase
More informationEaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC
Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH
More informationTECHNICAL DATA SHEET KVA UPS Systemss
Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
REC EPO STATUS BAT OUTPUT MUTE Critical Power Technical Data Sheet Uninterruptible Power Supply TLESM_UL_015-090_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationSeries. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM
Series 6 and 10 kva Rack Mount On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set
More information10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph
VEGA INDUSTRIAL UNINTERRUPTIBLE POWER SUPPLY 10 20KVA 3Ph/1Ph 10 120KVA 3Ph / 3Ph - 6 pulse SCR rectifier - IGBT inverter - Power output transformer - Low and stable ripple on battery for the highest battery
More informationPOWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting
POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series
More informationTechnical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work
Digital Energy Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91
More informationThree Phase UPS Systems Range: 10 to 500kVA
Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying
More informationEFFEKTA Power Supplies
EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TM SG Series 100 &120 PurePulse TM SG Series 60 & 80 PurePulse SGSE_060-120_S1_UPS_GE_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino
More informationTechnical Data Sheets
Digit al Energy T M L P Seri es Di gi ta l Energy TM LP Series Digita l Energ y T M L P Se rie s GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply
More informationTRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
TRIMOD HE UPS MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES TRIMOD HE HIGH performance HIGH efficiency LOW environmental impact DEVELOPMENTS
More informationTechnical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER
Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...
More informationSmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS
SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS MODEL NUMBER: S3M60KX Highlights Best-in-class footprint and power density minimize space requirements for up to 60kVA
More informationU N I T Y / Three-Phase Uninterruptible Power Systems UT380 and UT Hz
U N I T Y / I TM Three-Phase Uninterruptible Power Systems UT380 and UT3100 60 Hz Guide Specifications LTQ-1002B 12/95 In this document, explanatory notes are set in italics. Each note provides additional
More informationEATON 9315 UPS 200 TO 300 KVA Specifications
EATON 9315 UPS 200 TO 300 KVA Specifications Input Voltage Range See table below Frequency Range (60Hz) 57-64 Hz (50Hz) 47-53 Hz Surge Protection Meets ANSI C62.41, Category A & B EN 50091-2 and EN50082-2
More informationTechnical Specification SENTINEL PRO
Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES
More informationTOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS
INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...
More informationSmart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass
Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass APC Smart-UPS VT, 24 kw / 30 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9
More information1.1 GENERAL CHARACTERISTICS
1.1 GENERAL CHARACTERISTICS General characteristics - Frame Values Unit Model: Conceptpower DPA 500, UL Series Power, rated: Apparent 500 kva Active 500 kw Power, range 100-3000 kw UPS type: online, transformerless,
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TLES_040-120_S1_UPS_GE_Floor_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41
More informationSeries. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM
Series 6 and 10 kva Tower On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set user
More informationPower Lynx 3 Uninterruptible Power System (UPS) Technical Specifications
Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible
More informationMKN-DSP SERIES - THREE PHASE
Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /
More informationTender Technical Specification. For Three phase UPS, on line double conversion (VFI) 120 kva kw
Tender Technical Specification For Three phase UPS, on line double conversion (VFI) 120 kva - 120 kw 1 di 14 Index 1 GENERAL REQUIREMENTS... 4 1.1 SUBJECT AND AGREEMENT TYPE... 4 1.2 CONDITIONS... 4 2
More informationSmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option
SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT20KX Highlights On-line double-conversion topology, VFI operation
More informationPOWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division
POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com
More informationPOWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division
POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com
More informationDefender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications
Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting
More informationPower+ CLASSIC. 20/30 kva, 3x208 Vac
Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies
More informationEasy UPS 3M. Operation 01/
Easy UPS 3M Operation 01/2019 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to in this guide are
More informationMarketing Management Team of Europe
Emerson Network Power Liebert NXe UPS GUIDE SPECIFICATIONS For a 10 to 20 kva (50 or 60Hz) Parallelable Digital Uninterruptible Power Supply (UPS) System - 1 - Contents 1.1 SUMMARY... 3 1.2 STANDARDS...
More informationTECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS
Tender Paper TECHNICAL SPECIFICATIONS FOR 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS Contents 1. General 2. Tender submission requirements 3. Environmental
More informationCobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications
Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System
More informationSmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9
SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 MODEL NUMBER: AL-84111 Specifications OUTPUT Output Volt Amp Capacity (VA) 2200 Output kva Capacity
More informationGalaxy VX. 480 V UPS System Technical Specifications 07/
Galaxy VX Technical Specifications 07/2017 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to in this
More informationTender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 27 kw
Tender Technical Specification For Three phase UPS, on line double conversion (VFI) 30 kva 27 kw 1 di 14 Index 1 GENERAL REQUIREMENTS... 4 1.1 SUBJECT AND AGREEMENT TYPE... 4 1.2 CONDITIONS... 4 2 GENERALI
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company imagination at work QUITO: Elia Liut N45-26 y Edmundo Chiriboga Telf:
More informationLiebert APM UPS. For a 30 to 150 kva / kw (50 or 60Hz) Modular Digital Uninterruptible Power Supply (UPS) System. V nd February 2010
Liebert APM UPS For a 30 to 150 kva / kw (50 or 60Hz) Modular Digital Uninterruptible Power Supply (UPS) System V-1.0 22nd February 2010 Contents 1.1 SUMMARY...1 1.2 STANDARDS...1 1.3 SYSTEM DESCRIPTION...2
More informationMaster DIALOG INDUSTRY RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs Emergency devices (lights/alarms) Electro-medical devices Telecommunication devices Industrial applications
More informationgimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy
GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,
More informationGalaxy VX. 380 V, 400 V, 415, and 440 V UPS System Technical Specifications 12/
Galaxy VX Technical Specifications 12/2017 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to in this
More informationAurora Single Phase Emergency Lighting Inverters
Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available
More informationTELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)
Local Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)
More information.3 Section Waste Management and Disposal.
Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section
More informationTELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)
LOCAL Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)
More informationAPC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply
APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous
More informationConceptpowerTM Modular kVA
TECHNICAL SPECIFICATIONS ConceptpowerTM Modular 10-15-20-30-40kVA Uninterruptible Supply (UPS) Modular, n+1 redundant, three-phase On-line, Double-Conversion, VFI Classic-Line 10-40kVA Gemini-Line 10-30kVA
More informationModular UPS «AGIL» Stay on! Changing the rules for critical business continuity :
Modular UPS «AGIL» Stay on! Changing the rules for critical business continuity : Scalable Reliable Fault tolerant Dynamic Source Transfer Efficient battery management Technology in action A significant
More informationUPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES INDEX General characteristics page 4 Modular page 12 Conventional page 32 Line-interactive page 44 Communication
More informationPQube 3 Modbus Interface
PQube 3 Modbus Interface Reference manual Revision 1.9 Modbus Interface Reference Manual 1.9- Page 1 Table of Contents 1. Background... 3 2. Basics... 3 2.1 Registers and Coils... 3 2.2 Address Space...
More informationUPS. MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES
UPS MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to 10000 THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES Modular UPS redundant and upgradable up to 10k with perfomance and functions
More informationFortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications
Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state
More informationVentilation in balance
Ventilation in balance AIRLINQ - DIGITAL BMS PARAMETERS FOR MODBUS RTU RS485 BASIC INFORMATION The present document is only valid for air handling units with firmware version 6. or newer. The firmware
More informationSymmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw
Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw Modular, scalable, high efficiency power protection for data centers. The Schneider Electric Symmetra TM PX 250/500 UPS provides high-performance,
More informationPOWERTRONIX QUASAR 5-40 KVA
POWERTRONIX QUASAR 5-40 KVA DT 0251 E00 TECHNICAL DATA Rev. Description Date Checked Released Date Type of doc. Page n Pag. Tot. ISSUED 07.03.2000 E.Borsa 07.03.2000 Approved A.Gorlani Pag.1/6 Cod. DT251
More informationFortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications
Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting
More informationTechnical data sheets
GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company
More informationFeatures and Benefits
Symmetra PX 250/500 Scalable from 25 kw to 500 kw, Parallel-capable up to 2,000 kw Modular, Scalable, Ultra-high Efficiency Power Protection for Data Centers High-performance, right-sized, modular, hot-scalable,
More informationIlluminator Series CR NEMA 3R
Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the
More informationKEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader
More informationCONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...
CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. INVERTER OPERATION... 11 6. TROUBLE SHOOTING GUIDE....... 16 7.
More informationMaster Plus kva
Local Area Networks (LAN) ServerS Data Centers Telecommunication devices e-business (Servers Farms, ISP/ASP/POP) Industrial Processes Industrial PLCs Electromedical Devices Emergency Devices (lights/alarms)
More informationTLE Series UPS 400/500 kw With eboost Technology
TLE Series UPS 400/500 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical power
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TLESM_030-180_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91
More informationEMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)
LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTRES BM Plus Series BMLM 10-20 kva Single-phase BMLT 10-120 kva Three-phase CASH REGISTERS TELECOM- MUNICATIONS DEVICES E-BUSINESS (Servers Farms, ISP/ASP/POP)
More informationTLE Series UPS 160/200/225/250 kw with eboost Technology
TLE Series UPS 160/200/225/250 kw with eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical
More informationgreen power 2.0 and Delphys BC
green power 2.0 and Delphys BC Modbus - TCP / Jbus serial link Installation and operating manual GB Index 1. Foreword 4 2. Safety Requirement 4 2. 1. Using conditions 4 2. 2. DELPHYS Green Power Operating
More informationCONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9
USER MANUAL 1 CONTENTS 1. INTRODUCTION... 1 2. SAFTY INSTRUCTION... 3 3. CABLE CONNECTION... 4 4. SYSTEM DESCRIPTION... 5 5. OPERATION... 9 6. TROUBLE SHOOTING GUIDE... 25 7. OPERATION MODES..... 27 8.
More informationTechnical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality
GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino
More informationMEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA
UPS MODULAR SINGLE-PHASE from 1250 to 10000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES SINGLE PHASE MODULAR UPS Redundant modular UPS, expandable up to 10 kva with the best
More informationSymmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers
Symmetra PX 100 kw Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers High-performance, right-sized, 3-phase power protection with high efficiency and availability
More information