Question Number: 1. (a)
|
|
- Ada Barker
- 6 years ago
- Views:
Transcription
1 Session: Summer 2008 Page: 1of 8 Question Number: 1 (a) A single winding machine cannot generate starting torque. During starting the switch connects the starting winding via the capacitor. The capacitor causes phase lead (a time shift) between the starting winding current and the main winding current. The starting winding is aligned at 90 to the main winding so the combination of main winding and starting winding creates a field which rotates from one axis to the other. This rotating field generates torque to start the machine. Once the machine is rotating the starter winding may be switched out and the main winding will continue to provide a pulsating torque. Diagram Description [6 ] [2 ]
2 Session: Summer 2008 Page: 2of 8 Question Number: 1 (b) Total Electricity Cost for 2 years operation with standard motor: 8kW Electricit y Cost (standard) = 2 years*365 days* 24 hours * * 0.15 / kwh= 24, Total Electricity Cost for 2 years with high efficiency motor: 8kW Electricit y Cost (Efficient) = 2 years*365 days* 24 hours * * 0.15 / kwh= 23, Saving in electricity with high efficiency motor = 24,734-23,360 = 1,374 Since the 2 year saving is greater than the 500 price difference between standard and high efficiency motor we should choose the high efficiency motor. (c) Fuse Characterisitic Time (t) (Log Scale) Typical Melting Time Curves Slow Blow General Purpose Fuse Rating Current (I) [6 ] Typical Application requiring a slow blow fuse: A Motor which draws high inrush during starting. Typical Application requiring a Fast Blow fuse: A Semiconductor load such as a rectifier. [1 mark] [1 mark]
3 Session: Summer 2008 Page: 3of 8 Question Number: 1 (d) The four main functions with the appropriate components are as follows: (1) Isolation Lockable MCB or Isolator (2) Short-circuit protection A magnetic coil in the MCB which activates on high current, opening the supply to the load (3) Overload protection A bi-metallic strip in the MCB which bends when heated OR a Bi-metallic thermal overload relay (Motor) (4) Power switching Electromagnetic contactor (e) N S = (f 60)/p = (10 60)/3 = 200 revs/min. N R = 200 4% = 192 revs/min. One problem of running the motor at such a low speed is that the temperature of the motor can rise as there may not be enough air being drawn along the cooling fins of the motor. A solution is to use a separate cooling fan to assist in the motor cooling. Total Question 1 [40 marks]
4 Session: Summer 2008 Page: 4of 8 Question Number: 2 (a) (b) (c) V a = E a + R i a a E = V R 2πN 60Ea Ea = kaφ kaφ = 60 2πN Rotationallosses= E i P P nm a a a a nm i a a = = 180V = = 0.859Vs / A 2π 2000 = 0 ( no load) Rotationallosses= 180V 1= 180W Factors contributing to rotational losses: Iron losses Windage Friction [5 marks] [3 marks] (d) If the field current was reduced then the the flux φ would be reduced and the machine would have to rotate faster in order to produce the same back emf E a. Therefore the machine would speed up. [6 marks] Total Q2 [30 marks]
5 Session: Summer 2008 Page: 5of 8 Question Number: 3 (a) The peak load power requirement is 10 kw [2 marks] (b) The average load power requirement is 4kW 5s+ 10kW 5s+ 2kW 10s = 4.5kW 20s [6 marks] (c) The root mean square load power is (d) = 5.57kW Peak Power requirement requires that the motor rating be greater than the peak load power / (1+service factor) = 10kW / (1.2) = 8.33kW The rms power requirement requires that the motor rating be greater than rms load power = 5.57kW [10 marks] (e) In this case the peak power requirement dominates and an 8.33kW motor is required. 2π N 60P 60 10kW P= T T = = = 47. 7Nm 60 2πN 2π 2000 [4 marks] Total Q3 [30 marks]
6 Session: Summer 2008 Page: 6of 8 Question Number: 4 (a) Q4 (a) H1 is the motor overload tripped indicator and H2 is the motor run indicator. S1 is the stop push-button and S2 is the start push-button. (b) The utilisation categories cover the main application areas foe alternating current (AC-Categories) and direct current (DC-Categories). For normal operation of contactors they define the making and breaking conditions at rated operational current (Ie) and at rated operational voltage (Ue). They depend on (1) the nature of the load to be switched (resistive, squirrel cage motor, etc), (2) the conditions under which making and breaking occurs (motor started or stalled, reversing direction of operation, etc.). The operating rate is less than 30 starts per hour and standard motors are designed for 6 starts per hour. Applications AC-1: this applies to all loads supplied by alternating current at a power factor greater than 0.95, for example resistive loads. Also a low number of cycles/hour operation. AC-2: starting and inching of asynchronous 3-phase slip-ring motors. AC-3: controlling the full load breaking current for squirrel cage motors, and breaking with motor running. AC-4: breaking the stalled rotor current for a squirrel cage motor.
7 Session: Summer 2008 Page: 7of 8 Question Number: 4 (cont.) (c) (i) AC Input Smoothing Capacitor 3-Phase Motor Rectifier (AC to DC) Inverter (DC to AC) Figure 1 Block diagram of frequency inverter Figure 2 More detail on frequency inverter The rectifier converts the supply voltage, single-phase or three-phase A.C. at 50 hertz, to a D.C. value. The D.C. has ripples which the filter capacitor smoothes out to give a constant D.C. value (straight line). This signal is the fed into an inverter that converts the D.C. back to an A.C. signal at whatever frequency is desired, depending on the required motor speed. To switch the current from D.C. to A.C. IGBT s are used. Insulated Gate Bipolar Transistor (IGBT) is a special transistor which is controlled by a very low voltage, hence there is no relation between the energy necessary for control and the current switched. Each time the device is switched puts stress on the semiconductor, because of the dv/dt relation due to the high speed switching. To minimise this stress, inductances and switching circuits comprised of resistors, capacitors and diodes are employed. In order to achieve a constant torque whatever the speed, it is necessary to maintain a constant flux. This means that the voltage and frequency must evolve simultaneously and in the same proportion. This is achieved using the Pulse Width Modulation (PWM) technique, as the width of the pulse is increased, the effective voltage is increased. [9 marks]
8 Session: Summer 2008 Page: 8of 8 Question Number: 4 (cont.) (c) (ii) Advantages of Inverter control over DOL Range of speeds available Soft start whereby speed ramps up slowly reducing sudden mechanical jerks Soft stop available Regenerative braking possible Direction is easily reversed using software Overload current value is programmable Disadvantages of Inverter control over DOL At low speeds, cooling may not be sufficient At high speeds, mechanical problems with bearings, fixings coming loose Cost [5 marks] Total Q4 [30 marks]
EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION
EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION 1. What is meant by drive and electric drive? Machines employed for motion control are called drives and may employ any one of the prime movers for
More informationStarting of Induction Motors
1- Star Delta Starter The method achieved low starting current by first connecting the stator winding in star configuration, and then after the motor reaches a certain speed, throw switch changes the winding
More informationDirect On Line (DOL) Motor Starter. Direct Online Motor Starter
Direct On Line (DOL) Motor Starter Direct Online Motor Starter Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting.
More informationSHRI ANGALAMMAN COLLEGE OF ENGINEERING AND TECHNOLOGY (An ISO 9001:2008 Certified Institution) SIRUGANOOR, TIRUCHIRAPPALLI
SHRI ANGALAMMAN COLLEGE OF ENGINEERING AND TECHNOLOGY (An ISO 9001:2008 Certified Institution) SIRUGANOOR, TIRUCHIRAPPALLI 621 105 DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE1205 - ELECTRICAL
More informationSDC,Inc. SCR-Regenerative Ac Drive
SDC,Inc WWW.STEVENSDRIVES.COM APPLICATION NOTE #: AN_REG_GEN000 EFFECTIVE DATE: 12 MAR 02 SUPERSEDES DATE: Original NO. OF PAGES: 10 SCR-Regenerative Ac Drive Using a regeneration controller with adjustable-frequency
More informationAmerican Traction Systems. DC Bus Capacitorss. Total. Dual Chopper Module. Dual. Inverter. 750kW. 750kW Generator Module. Module
EFFECTIVE DATE JULY 28 204 OF 8 Dual Hybrid Ship Propulsion System 750V BUS Generator Generator Propulsion Propulsion Bus Capacitorss 50,000µF Total Traction Inverter Dual Inverterr e Power Inverter L
More informationFull Voltage Starting (Number of Starts):
Starting Method Full Voltage Starting (Number of Starts): Squirrel cage induction motors are designed to accelerate a NEMA inertia along a NEMA load curve with rated voltage applied to the motor terminals.
More information(d) None of the above.
Dr. Mahalingam College of Engineering and Technology, Pollachi-3 (An Autonomous Institution affiliated to Anna niversity) CCET II (2016 Regulation) Name of Programme: B.E. (EEE) Course Code & Course Title:
More informationWhen to use a Soft Starter or an AC Variable Frequency Drive
White Paper When to use a or an AC Variable Frequency Product lines: Smart Motor Controllers (SMCs), AC Variable Frequency s (VFDs) Topic Page Introduction 2 Starting Methods 3 How does a VFD work? 7 Comparisons
More informationContactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660
Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,
More informationApplication Note CTAN #127
Application Note CTAN #127 Guidelines and Considerations for Common Bus Connection of AC Drives An important advantage of AC drives with a fixed DC is the ability to connect the es together so that energy
More informationA Novel Technique for Energy & Cost Effective Drives for AC & DC Motors
International Journal of Electrical Engineering. ISSN 0974-2158 Volume 3, Number 3 (2010), pp. 241--250 International Research Publication House http://www.irphouse.com A Novel Technique for Energy & Cost
More informationFATIMA MICHAEL COLLEGE OF ENGINEERING & TECHNOLOGY Senkottai Village, Madurai Sivagangai Main Road, Madurai
Department of Mechanical Engineering QUESTION BANK SUBJECT NAME: ELECTRICAL DRIVES AND CONTROL YEAR / SEM: II / III UNIT I INTRODUCTION PART-A (2 MARKS) 1. Define Drives 2. Define Electric Drives. 3. What
More informationVariable Speed Pumping
Variable Speed Pumping Jim Vukich Application Engineer ITT Corp. Malvern, PA Why Do It? Why Do It? Flow-Matching Minimize Starting & Stopping Flexibility Different Discharge Points, Flows Changing Conditions
More informationRVS-AX Instruction Manual
RVS-AX Analog Soft Starter 8-170A, 220-600V Instruction Manual Ver. 10/11/2009 2 Table of Content RVS-AX Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationChapter 5: DC Motors. 9/18/2003 Electromechanical Dynamics 1
Chapter 5: DC Motors 9/18/2003 Electromechanical Dynamics 1 Reversing the Rotation Direction The direction of rotation can be reversed by reversing the current flow in either the armature connection the
More informationDEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1
It is the mark of an educated mind to be able to entertain a thought without accepting it. DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1 1. Explain the Basic concepts of rotating machine. 2. With help
More informationTeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30
Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,
More information10. Starting Method for Induction Motors
10. Starting Method for Induction Motors A 3-phase induction motor is theoretically self starting. The stator of an induction motor consists of 3-phase windings, which when connected to a 3-phase supply
More informationVariable Speed Drives in Electrical Energy Management. Course Content
Variable Speed Drives in Electrical Energy Management Course Content Introduction & Overview The basic equation for a 3 phase electric motor is: N = rotational speed of stator magnetic field in RPM (synchronous
More informationPrinciples of iers (intelligent
Principles of iers (intelligent Energy Recovery System) Chapter 4 Table of Contents............... 4 1 Principles of the iers....................................... 4 2 Enabling Intelligent Energy Recovery
More informationPractical Variable Speed Drives and Power Electronics
Practical Variable Speed Drives and Power Electronics Malcolm Barnes CPEng, BSc(ElecEng), MSEE, Automated Control Systems, Perth, Australia AMSTERDAM BOSTON HEIDELBERG LONDON. NEW YORK OXFORD PARIS SAN
More informationGENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER
XXXX H02 GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER XXXX CONTROL OR REGULATION OF ELECTRIC MOTORS, GENERATORS, OR DYNAMO-ELECTRIC CONVERTERS; CONTROLLING TRANSFORMERS, REACTORS OR CHOKE
More informationBenefits of VFD for single to three phase conversion
Benefits of VFD for single to three phase conversion Agenda Differences between three phase and single phase power & effects on devices they power What is a VFD and how does it work when used for phase
More informationDHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING ME 6351 ELECTRICAL DRIVES AND CONTROL UNIVERSITY QUESTIONS AND ANSWERS
DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING ME 6351 ELECTRICAL DRIVES AND CONTROL UNIVERSITY QUESTIONS AND ANSWERS 1) What is the Necessity of starter? UNIT 3 Two Marks Both
More informationEXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1
University f Jordan School of Engineering Department of Mechatronics Engineering Electrical Machines Lab Eng. Osama Fuad Eng. Nazmi Ashour EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1 OBJECTIVES To
More informationR13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]
Code No:RT32026 R13 SET - 1 III B. Tech II Semester Regular Examinations, April - 2016 POWER SEMICONDUCTOR DRIVES (Electrical and Electronics Engineering) Time: 3 hours Maximum Marks: 70 Note: 1. Question
More informationInduction Motor Control
Induction Motor Control A much misunderstood yet vitally important facet of electrical engineering. The Induction Motor A very major consumer of electrical energy in industry today. The major source of
More informationTechnical Explanation for Inverters
CSM_Inverter_TG_E_1_2 Introduction What Is an Inverter? An inverter controls the frequency of power supplied to an AC motor to control the rotation speed of the motor. Without an inverter, the AC motor
More informationSynchronous Motor Drives
UNIT V SYNCHRONOUS MOTOR DRIVES 5.1 Introduction Synchronous motor is an AC motor which rotates at synchronous speed at all loads. Construction of the stator of synchronous motor is similar to the stator
More informationABB machinery drives. Application guide Common DC system for ACS380 drives
ABB machinery drives Application guide Common DC system for ACS380 drives List of related manuals Drive manuals and guides ACS380 hardware manual ACS380 firmware manual ACS380 quick installation and start-up
More informationSt.MARTIN S ENGINEERING COLLEGE Dhulapally, Secunderabad
St.MARTIN S ENGINEERING COLLEGE Dhulapally, Secunderabad-500 014 Subject: STATIC DRIVES Class : EEE III TUTORIAL QUESTION BANK Group I QUESTION BANK ON SHORT ANSWER QUESTION UNIT-I 1 What is meant by electrical
More informationCircuit Diagram For Speed Control Of Slip Ring Induction Motor
Circuit Diagram For Speed Control Of Slip Ring Induction Motor A wound-rotor motor is a type of induction motor where the rotor windings are Compared to a squirrel-cage rotor, the rotor of the slip ring
More informationSECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
More informationElectrical Drives I. Week 11: Three phase Induction Motor Starting
Electrical Drives I Week 11: Three phase Induction otor Starting Starting Problem Definition: ' I r Rs Vs 2 R ' r S 2 Xeq At S=0 and S=1, thus the current can be determined as: ' I r st Vs 2 ' Rs Rr Xeq
More informationTWO MARK QUESTIONS-ANSWERS
TWO MARK QUESTIONS-ANSWERS DEPARTMENT: MECH SEMESTER : III SUBJECT CODE: ME2205 SUBJECT NAME: ELECTRIC DRIVES & CONTROL 1. Define Drive and Electric Drive. Drive: A particular system employed for motion
More informationTypes of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:
Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.
More informationMeasurement of induction motor characteristics
Measurement of induction motor characteristics ES163 Electrical and Electronic Systems MR TJ KENNAUGH School of Engineering, University of Warwick 27/01/01 Summary The aim of the laboratory is to increase
More informationEEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines
Department of Electrical Engineering Lecture Introduction to Electrical Machines 1 In this Lecture Induction motors and synchronous machines are introduced Production of rotating magnetic field Three-phase
More informationIJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online):
IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online): 2321-0613 Thermal Protection of Induction Motor using DSP Dipak Banbakode 1 Millan Sabat 2 Tanmay
More informationLecture 20: Stator Control - Stator Voltage and Frequency Control
Lecture 20: Stator Control - Stator Voltage and Frequency Control Speed Control from Stator Side 1. V / f control or frequency control - Whenever three phase supply is given to three phase induction motor
More informationECE1750, Spring Motor Drives and Other
ECE1750, Spring 2018 Motor Drives and Other Applications 1 Three-Phase Induction Motors Reliable Rugged Long lived Low maintenance Efficient (Source: EPRI Adjustable Speed Drives Application Guide) The
More informationAC/DC FFE converter power module
Sheet 1 PRODUCT DESCRIPTION The converter series FFE (Fundamental Front End) consists of a three-phase IGBT bridge working at mains frequency and works as rectifier/regenerative bridge allowing the flow
More informationPart- A Objective Questions (10X1=10 Marks)
Dr. Mahalingam College of Engineering and Technology, Pollachi-3 (An Autonomous Institution) CCET 3(2016Regulation) Name of Programme: B.E. (EEE) Course Code&Course Title: 16EET41 & Synchronous & Induction
More informationA. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.
DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings
More informationRE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW
Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No
More informationVALLIAMMAI ENGINEERING COLLEGE MECHANICAL ENGINEERING ANNA UNIVERSITY CHENNAI II YEAR MECH / III SEMESTER EE6351 - ELECTRICAL DRIVES AND CONTROL (REGULATION 2013) UNIT I INTRODUCTION PART-A (2 MARKS) 1.
More informationPAC TRAINING PUMP MOTORS
PAC TRAINING PUMP MOTORS 1 Basics Magnet supported from above N S N S Since unlike poles repel each other, the magnet will rotate Stationary Magnet 2 Basics N S Stationary Magnet 3 Basics N N S S Stationary
More informationELECTRICAL POWER and POWER ELECTRONICS
Introduction to ELECTRICAL POWER and POWER ELECTRONICS MUKUND R PATEL (cj* CRC Press Taylor & Francis Group Boca Raton London New York CRC Press is an imprint of the Taylor & Francis Croup, an informa
More informationELECTRIC MACHINES EUROLAB 0.3 kw
index SINGLE-PHASE MOTORS SPLIT-PHASE MOTOR DL 30130 CAPACITOR MOTOR DL 30140 UNIVERSAL MOTOR DL 30150 REPULSION MOTOR DL 30170 THREE PHASE ASYNCHRONOUS MOTORS SQUIRREL CAGE THREE PHASE ASYNCHRONOUS MOTOR
More informationCT430 - Soft Starters on Motor Applications
CT430 - Soft Starters on Motor Applications Bill Bernhardt Sr. Commercial Engineer May 16, 2018 PUBLIC Copyright 2018 Rockwell Automation, Inc. All Rights Reserved. 1 Topics Traditional Motor Starting
More informationPresentation Soft starters 0 Altistart 48 soft start - soft stop units
Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled
More informationANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS)
ANALYSIS OF WIND AND PV SYSTEMS 4.1 Wind Energy Conversion Systems (WECS) A wind energy conversion system (WECS) is composed of blades, an electric generator, a power electronic converter, and a control
More informationELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET
Candidate Code No. EST 2075 For Board Use Only Result Date Int Result Date Int ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed:
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationChapter 3.2: Electric Motors
Part I: Objective type questions and answers Chapter 3.2: Electric Motors 1. The synchronous speed of a motor with 6 poles and operating at 50 Hz frequency is. a) 1500 b) 1000 c) 3000 d) 750 2. The efficiency
More informationSOLSTART Instruction Manual
Solstart Analog Soft Starter 8-58A, 220-600V Instruction Manual Ver. 23/03/2009 2 Table of Content SOLSTART Instruction Manual 1. TABLE OF CONTENT 1. Table of Content...2 2. Safety & Warnings...3 2.1 Safety...3
More informationStator rheostat, Autotransformer Star to Delta starter and rotor resistance starter.
UNIT-IV 1.What are the types of starters? Stator rheostat, Autotransformer Star to Delta starter and rotor resistance starter. 2. List out the methods of speed control of cage type 3-phase induction motor?
More information9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc.
Chapter 2 MOTOR CLASSIFICATION 1 In general, motors are classified according to the type of power used (AC or DC) and the motor's principle of operation. AC DC Motor Family Tree 2 DC MOTOR CONNECTIONS
More informationELECTRONIC SOFT STARTERS. S Gibson
ELECTRONIC SOFT STARTERS S Gibson Electronic soft starters, although a relatively new member to the family of power technology, have proved to be technically sound and versatile in the starting of belt
More informationInverter control of low speed Linear Induction Motors
Inverter control of low speed Linear Induction Motors Stephen Colyer, Jeff Proverbs, Alan Foster Force Engineering Ltd, Old Station Close, Shepshed, UK Tel: +44(0)1509 506 025 Fax: +44(0)1509 505 433 e-mail:
More informationVARIABLE FREQUENCY DRIVE AND ITS INDUSTRIAL APPLICATIONS
VARIABLE FREQUENCY DRIVE AND ITS INDUSTRIAL APPLICATIONS Ms. Mrunal Khadke 1 Mr. V. S. Kamble 2 1 Student, Department of Electrical Engineering, AISSMS-IOIT, Pune, Maharashtra, India 2 Assistant Professor,
More informationINSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING
Course Name Course Code Class Branch INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad - 500 0 DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING : Static Drives : A60225 : III -
More informationElectrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)
Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition) 1. Which drawing type shows physical details as seen by the eye? 2. Which drawing is similar to a pictorial drawing but has
More informationVariable Speed Drives Controlling Centrifugal Pumps Energy Savings
2018 Clean and Safe Drinking Water Workshop Hotel Gander Variable Speed Drives Controlling Centrifugal Pumps Energy Savings Presenter: Dave Galbraith What is a Variable Speed (Frequency) Drive? AKA VFD,
More informationAn Engineering Guide to. Soft Starters
An Engineering Guide to Soft Starters Contents 1 Introduction 5 1.1 General 5 1.2 Benefits of soft starters 5 1.3 Typical Applications 6 1.4 Different motor starting methods 7 1.5 What is the minimum
More information2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4
CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power
More informationASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.
ASHRAE - Variable Speed Drives By Dan Watkins, LEED BD+C Bornquist, Inc. Adjustable Frequency Drive Fundamentals How does a VFD actually work VS Pumping Analysis VS Pumping Features Harmonics VFDs and
More informationCódigo de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código
Letra de código Código de rotor bloqueado Rotor bloqueado, Letra de código kva / hp kva / hp A 0.00 3.15 L 9.00 10.00 B 3.15 3.55 M 10.00 11.00 C 3.55 4.00 N 11.00 12.50 D 4.00 4.50 P 12.50 14.00 E 4.50
More informationDesign, Engineering, and Manufacturing of Motors for Electric Vehicle Applications
Design, Engineering, and Manufacturing of Motors for Electric Vehicle Applications Mark Steffka Email: msteffka@ieee.org FR-AM-5 History of Electric Drives in Transportation 2 Why Use Electric Drives?
More informationELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET
Candidate Code No. EIN 08 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three
More informationIntroduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung
Introduction to Pekik Argo Dahono Electrical Energy Conversion Research Laboratory Institute of Technology Bandung Why Electric Drives Electric drives are available in any power. They cover a wide range
More informationWARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.
SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.
More information2. Draw the speed-torque characteristics of dc shunt motor and series motor. (May2013) (May 2014)
UNIT 2 - DRIVE MOTOR CHARACTERISTICS PART A 1. What is meant by mechanical characteristics? A curve is drawn between speed-torque. This characteristic is called mechanical characteristics. 2. Draw the
More informationYaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.
Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW) Page 1 Introduction This manual is divided into three sections:
More informationTable of Contents. Foreword...xiii. Chapter One Introduction, Objectives of the Guide...1
Table of Contents Foreword...xiii Chapter One Introduction, 9 1.1 Objectives of the Guide...1 Chapter Two Pumping System Hydraulic Characteristics, 3 2.1 System Characteristics...3 2.2 Pump Curves...9
More informationWHY USE ELECTRONIC VARIABLE SPEED DRIVES ON CONVEYOR APPLICATIONS. Mr. Howard Dunn ABB Automation (Pty) Limited, RSA
INTRODUCTION WHY USE ELECTRONIC VARIABLE SPEED DRIVES ON CONVEYOR APPLICATIONS Mr. Howard Dunn ABB Automation (Pty) Limited, RSA As customer demands for lower prices, increased quality and shorter delivery
More informationPHY 152 (ELECTRICITY AND MAGNETISM)
PHY 152 (ELECTRICITY AND MAGNETISM) ELECTRIC MOTORS (AC & DC) ELECTRIC GENERATORS (AC & DC) AIMS Students should be able to Describe the principle of magnetic induction as it applies to DC and AC generators.
More informationEE6351 ELECTRICAL DRIVES AND CONTROL UNIT 5 CONVENTIONAL AND SOLID STATE SPEED CONTROL OF A.C. DRIVES PART A
EE6351 ELECTRICAL DRIVES AND CONTROL UNIT 5 CONVENTIONAL AND SOLID STATE SPEED CONTROL OF A.C. DRIVES PART A 1. What are the different types of slip power control system? Kramer system, Scherbius system..
More informationPretest Module 21 Units 1-4 AC Generators & Three-Phase Motors
Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors 1. What are the two main parts of a three-phase motor? Stator and Rotor 2. Which part of a three-phase squirrel-cage induction motor is a
More informationAUCOM WHITE PAPER SERIES GET YOUR MOTOR RUNNING. An introduction to reduced voltage starting of three phase induction motors
AUCOM WHITE PAPER SERIES GET YOUR MOTOR RUNNING An introduction to reduced voltage starting of three phase induction motors GET YOUR MOTOR RUNNING WHITE PAPER #1 Reduced voltage starting of three phase
More informationElectrical Machines -II
Objective Type Questions: 1. Basically induction machine was invented by (a) Thomas Alva Edison (b) Fleming (c) Nikola Tesla (d) Michel Faraday Electrical Machines -II 2. What will be the amplitude and
More informationInstallation Manual for DC Injection Brake Units
Power Drive Services INJ Series DC brake modules PDS 11-30-100A Page 1 of 17 Issue 15 Contents. 1. Safety. 2. Installation. 3. Setting Up. 4. Wiring Diagrams. 5. Specifications. 6. Selection. 7. Timing
More informationECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Lecture 8 Motor Control Circuits
ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Text Book: Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015. Paul I-Hai Lin, Professor
More informationAC Motors vs DC Motors. DC Motors. DC Motor Classification ... Prof. Dr. M. Zahurul Haq
AC Motors vs DC Motors DC Motors Prof. Dr. M. Zahurul Haq http://teacher.buet.ac.bd/zahurul/ Department of Mechanical Engineering Bangladesh University of Engineering & Technology ME 6401: Advanced Mechatronics
More informationELECTRONIC EQUIPMENT DISTRIBUTION POWER ELECTRONIC COMPONENTS
ELECTRONIC EQUIPMENT DISTRIBUTION POWER ELECTRONIC COMPONENTS Founded in 1975, SECOM is a leading distributor in the Power Electronic Components market. Over time the company evolved, becoming an important
More informationMotor Protection Fundamentals. Motor Protection - Agenda
Motor Protection Fundamentals IEEE SF Power and Energy Society May 29, 2015 Ali Kazemi, PE Regional Technical Manager Schweitzer Engineering Laboratories Irvine, CA Copyright SEL 2015 Motor Protection
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More informationEE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011
EE 742 Chap. 7: Wind Power Generation Y. Baghzouz Fall 2011 Overview Environmental pressures have led many countries to set ambitious goals of renewable energy generation. Wind energy is the dominant renewable
More informationQUESTION BANK SPECIAL ELECTRICAL MACHINES
SEVENTH SEMESTER EEE QUESTION BANK SPECIAL ELECTRICAL MACHINES TWO MARK QUESTIONS 1. What is a synchronous reluctance 2. What are the types of rotor in synchronous reluctance 3. Mention some applications
More informationAbstract- A system designed for use as an integrated starter- alternator unit in an automobile is presented in this paper. The
An Integrated Starter-Alternator System Using Induction Machine Winding Reconfiguration G. D. Martin, R. D. Moutoux, M. Myat, R. Tan, G. Sanders, F. Barnes University of Colorado at Boulder, Department
More informationDHANALAKSHMI COLLEGE OF ENGINEERING MANIMANGALAM. TAMBARAM, CHENNAI B.E. ELECTRICAL AND ELECTRONICS ENGINEERING
DHANALAKSHMI COLLEGE OF ENGINEERING MANIMANGALAM. TAMBARAM, CHENNAI B.E. ELECTRICAL AND ELECTRONICS ENGINEERING V SEMESTER EE2305 ELECTRICAL MACHINES II LABORATORY LABORATORY MANUAL 1 CONTENT S. No. Name
More informationTutorial 2. Controlled converter driven DC motor
ELEC4613 University of New South Wales School of Electrical Engineering & Telecommunications Tutorial 2. Controlled converter driven DC motor PWM converter driven DC motor 1. A separately excited DC motor
More informationIntroduction. Upon completion of Basics of AC Drives you should be able to: Explain the concept of force, inertia, speed, and torque
Table of Contents Introduction...2 Siemens AC Drives and Totally Integrated Automation...4 Mechanical Basics...6 AC Motor Construction...15 Developing A Rotating Magnetic Field...19 Rotor Construction...22
More informationChapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.
Chapter 8 Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Article 430 of the NEC covers application and installation of
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More informationDEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK 16EET41 SYNCHRONOUS AND INDUCTION MACHINES UNIT I SYNCHRONOUS GENERATOR 1. Why the stator core is laminated? 2. Define voltage regulation
More informationELECTRIC MACHINES EUROLAB 0.3 kw
index SINGLE-PHASE MOTORS SPLIT-PHASE MOTOR DL 30130 CAPACITOR MOTOR DL 30140 UNIVERSAL MOTOR DL 30150 REPULSION MOTOR DL 30170 THREE PHASE ASYNCHRONOUS MOTORS SQUIRREL CAGE THREE PHASE ASYNCHRONOUS MOTOR
More informationCOLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES
KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES YEAR / SEM : IV / VII UNIT I SYNCHRONOUS RELUCTANCE
More informationContents. Review of Electric Circuitd. Preface ;
Preface ; Chapter 1 Review of Electric Circuitd 1.1 Introduction, 1 1.2 Direct Circuit Current, 1 1.2.1 Voltage, 3 1.2.2 Power, 3 1.2.3 Ohm's Law, 5 1.2.4 KirchhofTs Laws, 5 1.2.4.1 Kirchhoff s Current
More information