Experience and History

Size: px
Start display at page:

Download "Experience and History"

Transcription

1 Experience and History 1956 Battery no-break 1994 New Mfg Facility 500kVA System kVA System IC with Inner Rotor x1600 MV System 1969 First Diesel CPS System (300 kva) kVA Dual Output System Move to Almelo New Mfg and Test Stand 1600kVA System kVA Dual Output 2004

2 Major Components Choke 80% - 20% Tap - Direct Connection Provides Isolation for Load Part of Active Filter Impedance Matched with Generator Induction Coupling Outer Rotor Inner Rotor 1800 rpm 2 pole AC Winding DC Winding Diesel Engine Engine is preheated Engine is pre-lubricated Gravity fed fuel system Starting redundancy (n+2) Two starting motors Two starting batteries Direct Generator Start Options Starting ONLY the diesel engine clutch open generator already running Generator 1.4 to 1.6 times rating 4 Pole AC Winding 1800 rpm Active Filter

3 WHAT WE DO The Problems 1- Spikes 2- Frequency Variations 3- Voltage Sags 4- Outages 5- Harmonic Distortions 6- Transients The Solution The RESULT 7- Continuous Quality Power

4 Power Conditioning Voltage Regulation 1% Frequency Regulation 1% Harmonics Attenuation, THD < 3% Power Factor Improvement, >PF 0.98 Peak Voltage Protection

5 HARMONIC FILTERING - Peak Voltage Protection High impedance path from Supply to Load through the Choke blocks Supply harmonics Z Input = 55% Z Choke = 50% Z = 49% Z = 1% Z Output = 7% Low impedance path from Load to Earth through Alternator absorbs Load harmonics Z Gen = 6% 1. Removes harmonics generated by both the load and the mains supply 2. No power electronics (e.g. Input rectifiers) are incorporated in design

6 Voltage Regulation PF Improvement Input pf is maintained at pf 0.98 or greater for almost all load conditions Active Power supplied by utility Supply Load Reactive Power supplied by alternator The Synchronous Alternator supplies all of the Reactive Power demanded by the load with the Mains supplying only Active Power

7 Fault Clearing Capabilities Upstream Short-circuit Downstream Short-circuit Up to 2xFLC Up to 14xFLC The Generator will maintain the supply to the load within Specification while supplying up to 2xFLC to an upstream fault

8 Complete UPS Solution!!!!!! 1800 kva CPS at 100% Load Mains Failure Main Voltage Output Voltage 1800 rpm Frequency 60.5 Hz 60 Hz 59.5 Hz Free-wheel Clutch Engaging Diesel Speed 1 sec. Diesel Start

9 ALL in ONE SOLUTION Diesel Engine Alternator Induction Coupling PFC Air Conditioning Standby Batteries Busduct & Cabling Fire Protection & Security UPS Inverters Spark-proof Lighting

10 HIGH Power SMALL Footprint <2400 sq ft (280sq meter) 5400 kva Total CPS 1350 kva Essential CAPABLE of 3kVA/sq.ft.

11 HIGH Efficiency Lower Operating Costs Efficient Total losses <4% 100% 97% Hitec UPS Inefficient Total losses >10% 100% <90%

12 PRODUCT CAPABILITIES Single Output CPS Units from 400kVA to 2750kVA 380V to 25kV 50 or 60 Hz Systems Containerized or Indoor Installation Plug & Play Modules Dual Output CPS Parallel Systems Medium Voltage Systems Isolated Redundant Distributed Redundant Master Slave

13 TECHNICAL FEATURES OF THE SOLUTION Uses Stored Kinetic Energy - 60 Hz Technology Easily Paralleled MV Applications up to 19,800kVA Integrated Power Factor Correction near Unity at Input Very Effective Filter for Spikes and Harmonic Distortion High Non-Linear Load Capability High Peak Current Capability (typical In.) Very Efficient with Low Operational Costs

14 REASONS WHY HITEC IS POWER TO RELY ON High Power in Small Foot Print - 3kVA/Sq Ft Nationwide and Global Service Organization 7/24/365 Hard, Resilient, Electrical System - 1% Regulation Unlimited Configurations and Installation Options NO Air-Conditioning and Associated Costs NO Battery Room Maintenance/Monitoring/Disposal Costs NO Energy Conversion in Power-Path

15 REASONS WHY HITEC IS PEOPLE TO RELY ON Worldwide and LOCAL Service Technicians Help desk available 7/24/365 Remote monitoring and diagnostic systems Engineer COST EFFECTIVE SOLUTIONS Responsive Project Management After The Sale On Site Customer Training

16 LESSONS LEARNED ACTIONS TAKEN Continual Process and Product Improvements Developed First Class Service Organization Improved Communications and Responsiveness Customer Oriented Business

17 RELY ON HITEC POWER PROTECTION

WELCOME! Today we d like to Introduce you to your North American Rotary UPS Solutions Partner!

WELCOME! Today we d like to Introduce you to your North American Rotary UPS Solutions Partner! WELCOME! Today we d like to Introduce you to your North American Rotary UPS Solutions Partner! BRINGS YOU Rotary UPS y Manufactured By Euro Diesel History OVER 20 YEARS IN SERVICE SERVING OVER 40 COUNTRIES

More information

CONTINUOUS POWER IN YOUR CONTROL KEM5

CONTINUOUS POWER IN YOUR CONTROL KEM5 CONTINUOUS POWER IN YOUR CONTROL KEM5 Simply Reliable Solutions to Power Quality Issues Banks, Data Centers, Telecoms, Airports, Manufacturing Processes & Major Research Projects, in fact all installations

More information

Diesel UPS/CPS systems Continuous power

Diesel UPS/CPS systems Continuous power Diesel UPS/CPS systems Continuous power Uninterruptible, continuous and conditioned power supply for mission critical applications est 1989 ACUTE DATA INFRAS TRATEGIES Power to rely on People to rely on

More information

NO-BREAK KS. Dynamic UPS system PRESENTATION

NO-BREAK KS. Dynamic UPS system PRESENTATION NO-BREAK KS Dynamic UPS system PRESENTATION Contents Chapter 1: Description of No-Break KS System...3 Chapter 2: Operation when mains power is available...4 Chapter 3: Operation when mains supply is disrupted...6

More information

Ride Through Solutions

Ride Through Solutions Ride Through Solutions Output power from 400 kva up to 1250 kva Environmentally-Friendly Continuous Power Bridges short voltage interruptions Continuous Power Conditioning Up to 30 seconds Ride Through

More information

Transforming Energy.. For Advanced Technology

Transforming Energy.. For Advanced Technology Transforming Energy.. Manufacturers of CE approved Transformers & Reactors Five Decades of Manufacturing Experience Manufacturers of Quality Reliable Transformers. Auto C 201,4 th Cross Peenya Induatrial

More information

Switchgear and Distribution Systems for Engineers and Technicians

Switchgear and Distribution Systems for Engineers and Technicians Switchgear and Distribution Systems for Engineers and Technicians WHAT YOU WILL LEARN: How to identify typical characteristics of an industrial distribution system Become familiar with the main components

More information

D Series: UPS UPTO - 300KVA - Three / Three Phase

D Series: UPS UPTO - 300KVA - Three / Three Phase D Series: UPS UPTO - 300KVA - Three / Three Phase All in one D Series UPS High Power UPS Systems, Now in India Properties : Standard Properties 1GBT rectifier inverter technology Input power factor correction

More information

Master Plus kva

Master Plus kva Local Area Networks (LAN) ServerS Data Centers Telecommunication devices e-business (Servers Farms, ISP/ASP/POP) Industrial Processes Industrial PLCs Electromedical Devices Emergency Devices (lights/alarms)

More information

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung Introduction to Pekik Argo Dahono Electrical Energy Conversion Research Laboratory Institute of Technology Bandung Why Electric Drives Electric drives are available in any power. They cover a wide range

More information

MGE TM Galaxy TM 7000

MGE TM Galaxy TM 7000 MGE TM Galaxy TM 7000 Power efficiency for business continuity 160/200/250/300/400/500 kva > Performance 3 Phase Power Protection with high adaptability to meet the unique requirements of Medium to Large

More information

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations Standalone three-phase UPS system PowerWave 33 S3 60 120 kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations Innovative technology delivering unmatched

More information

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99 80-125 kva/kw E Three-Phase Double-Conversion On-Line Full Four Year Warranty www.stacoenergy.com Up to 99% Efficient n Lower energy costs and carbon footprint Compact & Reliable n Requires either front,

More information

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality Surabaya Seminar 2014 Ferdinand Sibarani, Surabaya, 30 th October 2014 Power Quality Content 1. Power quality problems 2. ABB s low voltage (LV) solution PCS100 AVC (Active Voltage Conditioner) PCS100

More information

Achieving the Highest Power Density in the Smallest Footprint

Achieving the Highest Power Density in the Smallest Footprint Achieving the Highest Power Density in the Smallest Footprint White Paper Summary For many years, mission critical applications have required high quality power conditioning and uninterruptable power to

More information

Power Protection Discrete Automation & Motion South Africa

Power Protection Discrete Automation & Motion South Africa Carel Oberholzer, ABB South Africa, May 2013 PCS100 Power Protection Discrete Automation & Motion South Africa May 13, 2013 Slide 1 Power Protection Agenda 1. Introduction of power protection 2. Overview

More information

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

Compact Energy Storage Module. Modular Systems, EPDS. Product overview Compact Energy Storage Module Modular Systems, EPDS Product overview ABB Power Products in energy storage Portfolio coverage Stationary Application Focus ESM Load leveling Spinning reserve ESM Behind-the-meter

More information

Power Electronics

Power Electronics www.nidec-industrial.com Power Electronics NIS. A Tradition in Excellence. Nidec Industrial Solutions: destined to be number one in industrial drive solutions With over 150 years of experience in the

More information

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A. LCL FILTERS INSTRUCTIONS MANUAL (M98121701-03-09A) (c) CIRCUTOR S.A. ------ LCL filters: Instructions Manual ----- Page 2 TABLE OF CONTENTS TABLE OF CONTENTS 2 1 CHECKS ON RECEIPT OF THE EQUIPMENT. 3 2

More information

3ph UPS NS3000 series kVA

3ph UPS NS3000 series kVA 3ph UPS UPS NS3000 SERIES NS3000 series 10-120kVA UPS NS3000 SERIES Main concepts in NS3000 design Last Generation 3ph UPS Features Fast and Simplified Intervention Range and Mechanical features NS3000

More information

Steve Schouten. Donna Densmore

Steve Schouten. Donna Densmore March 12, 2013 2 Steve Schouten Donna Densmore 3 Mike Carter Justin Kale 4 Basics Motor Loads Operation Advantages/ Disadvantages Sizing a VFD Power Quality Issues Source: Emerson Industrial Automation

More information

MASTERYS IP+ 10 to 80 kva

MASTERYS IP+ 10 to 80 kva MASTERYS IP+ 10 to 80 kva OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application. the information

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

Standby Power Systems

Standby Power Systems Source: Power Quality in Electrical Systems Chapter 13 Standby Power Systems The term standby power systems describes the equipment interposed between the utility power source and the electrical load to

More information

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options /2 Overview /2 Benefits /2 Design /6 Function /8 Selection and ordering data /8 Options Technical data /1 General technical data /15 Control properties /15 Ambient conditions /16 Installation conditions

More information

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES KEOR HP THREE-PHASE from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Legrand SUPERIOR PERFORMANCE SERVICE CONTINUITY AND ENERGY EFFICIENCY Legrand, world leader

More information

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99 65-500 kva Full Two Year Warranty Three-Phase Double-Conversion On-Line Up to 98% Efficient n Lower energy costs and carbon footprint Compact & Reliable n Requires either front, top or bottom access, so

More information

MGE TM Galaxy TM 7000 GFC

MGE TM Galaxy TM 7000 GFC MGE TM Galaxy TM 7000 GFC Grid Frequency Converter (GFC) for Shore Connection solution 500 kva Performance 3 Phase Power Protection with high adaptability to meet the unique requirements of Shore Connection

More information

MKN-DSP SERIES - THREE PHASE

MKN-DSP SERIES - THREE PHASE Output Power Factor 0.9 MKN-DSP SERIES - THREE PHASE Double conversion True On-Line UPS 3 Phase Input - 3 Phase Output 10 KVA 15 KVA 20 KVA 30 KVA 40 KVA 50 KVA 60 KVA Model for: 208/120 V 220/127 V /

More information

Simply Reliable Solutions for Continuous, High Quality Power Tradition. Technology. Innovation.

Simply Reliable Solutions for Continuous, High Quality Power Tradition. Technology. Innovation. Rotabloc Diesel Rotary UPS Systems Simply Reliable Solutions for Continuous, High Quality Power Tradition. Technology. Innovation. IEM Power Systems Rotary UPS is a fully integrated system comprising the

More information

TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 400/500 kw With eboost Technology TLE Series UPS 400/500 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical power

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

Induction Motor Control

Induction Motor Control Induction Motor Control A much misunderstood yet vitally important facet of electrical engineering. The Induction Motor A very major consumer of electrical energy in industry today. The major source of

More information

4100C BOSS AC Shovel Drive System Overview. WMEA Edmonton - June 2008

4100C BOSS AC Shovel Drive System Overview. WMEA Edmonton - June 2008 4100C BOSS AC Shovel Drive System Overview WMEA Edmonton - June 2008 Overview Drives Partnership with ABB Deck Plan / One-Line Schematic ISU (IGBT Supply Unit) Shovel Motion Inverters Cabling / Grounding

More information

Industrial PFC UPS System

Industrial PFC UPS System Based on Statron s leading A.T.I.S. (Advanced Technology Industrial System) platform, the S3000 range is a true-industrial UPS system using the latest Power Factor Corrected (PFC) IGBT rectifier technology.

More information

Reduction of Harmonic Distortion and Power Factor Improvement of BLDC Motor using Boost Converter

Reduction of Harmonic Distortion and Power Factor Improvement of BLDC Motor using Boost Converter May 215, Volume 2, sue 5 Reduction of Harmonic Distortion and Power Factor Improvement of BLDC Motor using Boost Converter 1 Parmar Dipakkumar L., 2 Kishan J. Bhayani, 3 Firdaus F. Belim 1 PG Student,

More information

GENERATOR DATA MAY 10, 2018

GENERATOR DATA MAY 10, 2018 Page 1 of 10 GENERATOR DATA MAY 10, 2018 For Help Desk Phone Numbers Click here Spec Information Generator Specification Frame: 449 Type: SR4 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 14.0

More information

GENERATOR DATA SEPTEMBER 29, 2015

GENERATOR DATA SEPTEMBER 29, 2015 Page 1 of 10 GENERATOR DATA SEPTEMBER 29, 2015 For Help Desk Phone Numbers Click here Spec Information Generator Specification Frame: 685 Type: SR4 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel:

More information

Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation

Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation Dynamic Reactive Compensation Providing stability, security, and reliability to the grid Installing a STATCOM at one

More information

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous

More information

Lesson 16: Asynchronous Generators/Induction Generators

Lesson 16: Asynchronous Generators/Induction Generators Lesson 16: Asynchronous s/induction s ET 332b Ac Motors, s and Power Systems et332bind.ppt 1 Learning Objectives After this presentation you will be able to: Explain how an induction generator erates List

More information

PowerWave 33 Efficient power protection for today s IT and process-related work environments

PowerWave 33 Efficient power protection for today s IT and process-related work environments ARTICLE OR CHAPTER TITLE PowerWave 33 Efficient power protection for today s IT and process-related work environments Cooling fan UPS control panel Maintenance bypass isolator Input supply isolator Slot

More information

Diesel generator set QSK95 series engine

Diesel generator set QSK95 series engine Specification sheet Diesel generator set QSK95 series engine 2750 kw - 3350 kw 60 Hz Data Center Continuous EPA Tier 2 emissions regulated Description Cummins commercial generator sets are fully integrated

More information

Est DCM Double Conversion Module 400kVA - 800kVA

Est DCM Double Conversion Module 400kVA - 800kVA Est.1968 DCM Double Conversion Module 400kVA - 800kVA The parallel operation of converters for increased output power or redundancy is commonplace but poses problems for large systems. A new approach is

More information

Liebert. FP 50Z kva

Liebert. FP 50Z kva Liebert FP 50Z 5 250 kva Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online faster and at a lower cost when search and social

More information

Sources, Effect, and melioration. Power Quality Problems. Asnil Elektro FT UNP

Sources, Effect, and melioration. Power Quality Problems. Asnil Elektro FT UNP Sources, Effect, and melioration of Power Quality Problems Asnil Elektro FT UNP Sources of Power Quality Problems Power Electrinic Devices Arcing Devices Load Switching Large Motor Starting Embedded Generation

More information

Designing and Maintaining a Pollution-Resilient Electric Power System. Managing Pollution Issues

Designing and Maintaining a Pollution-Resilient Electric Power System. Managing Pollution Issues Designing and Maintaining a Pollution-Resilient Electric Power System Tom McDermott IEEE/PES T&D Conference April 21-24, 2008 Chicago, IL Managing Pollution Issues Define the metrics, and measure them

More information

Master Plus kva

Master Plus kva LOCAL AREA NETWORKS SERVERS DATA CENTERS TELECOM MUNICATION DEVICES (Servers Farms, ISP/ASP/POP INDUSTRIAL PROCESSES INDUSTRIAL PLCS MEDICAL DEVICES EMERGENCY DEVICES ights/alarms Master Plus 100- kva

More information

IEEE Northern Canada & Southern Alberta Sections, PES/IAS Joint Chapter Technical Seminar Series

IEEE Northern Canada & Southern Alberta Sections, PES/IAS Joint Chapter Technical Seminar Series IEEE Northern Canada & Southern Alberta Sections, PES/IAS Joint Chapter Technical Seminar Series Designing Electrical Systems for On-Site Power Generation Apr 04 th /05 th, 2016, Calgary/Edmonton, Alberta,

More information

GE Industrial Solutions ES Group / UPS Solutions. GE Flywheel UPS. Flywheel Energy. An Integrated Solution

GE Industrial Solutions ES Group / UPS Solutions. GE Flywheel UPS. Flywheel Energy. An Integrated Solution GE Industrial Solutions ES Group / UPS Solutions GE Flywheel UPS Flywheel Energy Using An Integrated Solution Key Drivers that Makes GE Flywheel UPS Attractive Low Total Cost of Ownership / Flywheel 20

More information

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology TLE Series UPS 160/200/225/250 kw with eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information

ABB n.v Power Quality in LV installations

ABB n.v Power Quality in LV installations ABB n.v. - 1 - Power Quality in LV installations PQ problems in LV installations 750 500 250 Volts 0-250 -500 Amps -750 3000 2000 1000 0-1000 -2000-3000 10:25:43.72 10:25:43.73 10:25:43.74 10:25:43.75

More information

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution 10kVA - 60kVA Compact, Efficient, and Reliable Power Solution Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online faster and at

More information

Rental Power QSB7 series engine

Rental Power QSB7 series engine Specification sheet Rental Power QSB7 series engine 150 kva 200 kva 50 Hz 135 kw 180 kw 60 Hz Description This Cummins commercial generator set is a fully integrated power generation system, providing

More information

SDC,Inc. SCR-Regenerative Ac Drive

SDC,Inc. SCR-Regenerative Ac Drive SDC,Inc WWW.STEVENSDRIVES.COM APPLICATION NOTE #: AN_REG_GEN000 EFFECTIVE DATE: 12 MAR 02 SUPERSEDES DATE: Original NO. OF PAGES: 10 SCR-Regenerative Ac Drive Using a regeneration controller with adjustable-frequency

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

Variable Frequency Drives

Variable Frequency Drives We Make Energy Engaging Variable Frequency Drives Questline Academy Meet Your Panelist Mike Carter questline.com 2 Contents Basics Motor Loads Operation Advantages/ Disadvantages Sizing a VFD Power Quality

More information

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better Pump ED 101 Power Factor (Part 2) - - Electricity Behaving Better Joe Evans, Ph.D http://www.pumped101.com Last month we took a close look at the flow of voltage and current in purely resistive and inductive

More information

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Power+ CLASSIC. 20/30 kva, 3x208 Vac Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies

More information

DRIVE THE WATER CYCLE. January 10 TH 2013

DRIVE THE WATER CYCLE. January 10 TH 2013 DRIVE THE WATER CYCLE January 10 TH 2013 DRIVE THE WATER CYCLE EXTENDED FLOW CONTROLS Throttling control Bypass control Parallel Pump control VSD control THROTTLING CONTROL The operation point is modified

More information

400/230 Volt 60Hz UPS Power

400/230 Volt 60Hz UPS Power olt 60Hz Power Using ual Voltage standby generation and in one Nothing protects quite like Piller www.piller.com Contents 1 Abstract...3 2 Introduction...4 3 Alternative Power istribution...6 4 Integrating

More information

PI044G - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

PI044G - Winding 06 APPROVED DOCUMENT. Technical Data Sheet - Winding 06 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

Integration of Large Wind Farms into Electric Grids

Integration of Large Wind Farms into Electric Grids Integration of Large Wind Farms into Electric Grids Dr Mohammad AlZoubi Introduction Development WHAT IS NEXT!! Over the next 12 years, Europe must build new power capacity equal to half the current total.

More information

PI144J - Winding 05 APPROVED DOCUMENT. Technical Data Sheet

PI144J - Winding 05 APPROVED DOCUMENT. Technical Data Sheet - Winding 05 Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international

More information

Synchronous Generators I. Spring 2013

Synchronous Generators I. Spring 2013 Synchronous Generators I Spring 2013 Construction of synchronous machines In a synchronous generator, a DC current is applied to the rotor winding producing a rotor magnetic field. The rotor is then turned

More information

Novel High Efficiency UPS System

Novel High Efficiency UPS System Novel High Efficiency UPS System Yasuhiro OKUMA Senior General Manager Technology Planning Department Power Electronics Development Center Technology Development Group Fuji Electric Systems Co., Ltd. 1

More information

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction Technical brochure The Vector series The ABB comprehensive solution for automatic power factor correction 2 Applications The Vector series The Vector series The Vector series is a powerful and compact

More information

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz Specification sheet Diesel generator set QSK78 series engine 2750kVA - 3000kVA 50 Hz Description This Cummins commercial generator set is a fully integrated power generation system, providing optimum performance,

More information

Diesel generator set QSX15 series engine

Diesel generator set QSX15 series engine Specification sheet Diesel generator set QSX15 series engine 410 kw 455 kw 60 Hz Data Center Continuous EPA Emissions Description Cummins commercial generator sets are fully integrated power generation

More information

UPS5000-E (25-75 kva) Series

UPS5000-E (25-75 kva) Series Battery Integrated Uninterruptible Power System UPS5000-E (25-75 kva) Series HUAWEI TECHNOLOGIES CO., LTD. CONTENTS 02 Solution Overview 03 Customer Benefits 09 System Architecture and Key Components 12

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

HIGH POWER RECTIFIER SYSTEMS

HIGH POWER RECTIFIER SYSTEMS HIGH POWER RECTIFIER SYSTEMS STATE OF THE ART DESIGN AND ENGINEERING Dynapower Company is the world s largest independent manufacturer of High Power Rectifier Systems. We design, manufacture and test integrated

More information

MERU Solar Off-Grid Inverters

MERU Solar Off-Grid Inverters 1 kva / 2 kva Off-Grid Solar Inverters with LCD and LED displays 24 / 48 VDC battery versions for 1 kva and 48 VDC for 2 kva Pure sine wave with highest efficiency Fully configurable (PV / Grid priority

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

Machine, Panel, and Plant Level Solutions

Machine, Panel, and Plant Level Solutions Machine, Panel, and Plant Level Solutions Mark Stephens, PE Manager Industrial Studies Electric Power Research Institute 942 Corridor Park Blvd Knoxville, Tennessee 37932 Phone 865.218.8022 mstephens@epri.com

More information

PQC - STATCON The ultra fast Power Quality Compensator

PQC - STATCON The ultra fast Power Quality Compensator PQC - STATCON The ultra fast Power Quality Compensator PQC - STATCON The ultra fast power quality compensator PQC - STATCON is based on IGBT voltage source inverter technology. It is a shunt connected

More information

TLE Series UPS 750/1000 kw With eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology TLE Series UPS 750/1000 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical

More information

Synchronous Generators I. EE 340 Spring 2011

Synchronous Generators I. EE 340 Spring 2011 Synchronous Generators I EE 340 Spring 2011 Construction of synchronous machines In a synchronous generator, a DC current is applied to the rotor winding producing a rotor magnetic field. The rotor is

More information

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw DELPHYS GP Green Power 2.0 range 160 to 1000 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.

More information

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Workshop on Grid Integration of Variable Renewable Energy: Part 1 Workshop on Grid Integration of Variable Renewable Energy: Part 1 System Impact Studies March 13, 2018 Agenda Introduction Methodology Introduction to Generators 2 Introduction All new generators have

More information

Technical Data Sheets

Technical Data Sheets GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric

More information

There are two leading power conversion technologies used in formation charging rectifiers

There are two leading power conversion technologies used in formation charging rectifiers 1 2 3 A goal of any progressive battery manufacturer is to shorten formation time while reducing energy consumed during the process. The requirement to increase capacity while reducing operating expense

More information

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP) LOCAL Area Networks (LAN) ServerS DATA CENTRES CASH REGISTERS TELECOM- MUNICATIONS DEVICES e-business (Servers Farms, ISP/ASP/POP) INDUSTRIAL PLCs ELECTRO- MEDICAL DEVICES EMERGENCY DEVICES (Lights/Alarms)

More information

Diesel generator set QSK23 series engine

Diesel generator set QSK23 series engine Specification sheet Diesel generator set QSK23 series engine 545 kw - 725 kw 60 Hz Data Center Continuous Description Cummins commercial generator sets are fully integrated power generation systems providing

More information

POWERTRONIX QUASAR 5-40 KVA

POWERTRONIX QUASAR 5-40 KVA POWERTRONIX QUASAR 5-40 KVA DT 0251 E00 TECHNICAL DATA Rev. Description Date Checked Released Date Type of doc. Page n Pag. Tot. ISSUED 07.03.2000 E.Borsa 07.03.2000 Approved A.Gorlani Pag.1/6 Cod. DT251

More information

Rental Power QSL9 series engine

Rental Power QSL9 series engine Specification sheet Rental Power QSL9 series engine 250 kva - 300 kva 50 Hz 225 kw - 275 kw 60 Hz Description This Cummins commercial generator set is a fully integrated power generation system, providing

More information

Spec Information. Reactances Per Unit Ohms

Spec Information. Reactances Per Unit Ohms GENERATOR DATA Selected Model Spec Information Generator Specification Frame: 687 Type: SR4 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 521.0 Connection: SERIES STAR Housing: 00 Phases: 3 No.

More information

Alberto Carini, June 2013 MNS irpp The ABB s Power Distribution Units

Alberto Carini, June 2013 MNS irpp The ABB s Power Distribution Units Alberto Carini, June 2013 MNS irpp The ABB s Power Distribution Units What is MNS irpp (intelligent Remote Power Panel) ABB s MNS irpp offers complete power distribution and monitoring with up to 128 poles

More information

ECE1750, Spring Motor Drives and Other

ECE1750, Spring Motor Drives and Other ECE1750, Spring 2018 Motor Drives and Other Applications 1 Three-Phase Induction Motors Reliable Rugged Long lived Low maintenance Efficient (Source: EPRI Adjustable Speed Drives Application Guide) The

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply SGSE_400-500_S3_UPS_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications True double-conversion online single-phase UPS PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications Safeguarding your power supply has never been easier One factor has become increasingly

More information

2-marks question bank UNIT I - TRANSFORMERS UNIT II: AC MACHINES

2-marks question bank UNIT I - TRANSFORMERS UNIT II: AC MACHINES 2-marks question bank UNIT I - TRANSFORMERS 1. What is all day efficiency? 2. What are the applications of auto transformers? 3. Why transformer rating is expressed in KVA? 4. Does transformer draw any

More information

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric. Galaxy VM From 160 kva to 1000 kva Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that seamlessly integrates

More information

BATTERY FREE DC ENERGY STORAGE FOR UPS. Yorba Linda CA (714)

BATTERY FREE DC ENERGY STORAGE FOR UPS. Yorba Linda CA (714) BATTERY FREE DC ENERGY STORAGE FOR UPS Yorba Linda CA (714) 386-03800 Expect More From An Energy Storage Solution VYCON s VDC DC Flywheels VYCON s VDC/XE flywheel system stores and delivers reliable DC

More information

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products From 160 kva to 1000 kva Three-phase power protection 2 3 trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that seamlessly integrates into the

More information

2 MW Flywheel System Integration

2 MW Flywheel System Integration 2 MW Flywheel System Integration Colin Young System Engineer Kodiak Electric Association Will Galton Senior Project Manager ABB Inc. Project Overview 2 MW electric crane brought in to Kodiak to replace

More information

MGE Galaxy 5500 Marine

MGE Galaxy 5500 Marine MGE Galaxy 5500 Marine 20/30/40/60/80/100/120 kva UPS solutions for marine and offshore environments 20-to-120 kva, state-of-the-art, three-phase power protection designed to meet a wide range of requirements

More information

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 106 CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 5.1 INTRODUCTION Inherent characteristics of renewable energy resources cause technical issues not encountered with conventional thermal,

More information

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop] Power Electronics & [Simulink, Hardware-Open & Closed Loop] Project code Project theme Application ISTPOW801 Estimation of Stator Resistance in Direct Torque Control Synchronous Motor ISTPOW802 Open-Loop

More information