1 MAKING MODERN LIVING POSSIBLE Price List Water, Wastewater, and Irrigation Effective October 2012

2 VLT AQUA Drive Contents VLT AQUA Drives... 3 VLT AQUA Drive Panels...16 VLT High Power Drives...20 VLT Low Harmonic Drive Options and Accessories DrivePro Service Programs General Conditions of Sale and Warranty Section II Contents VLT Micro Drive... II-3 VLT 2800 Drive... II-4 VLT 2800 Drive Options and Accessories... II-5 VLT Drive Accessories... II-15 MCD 200 Soft Starter... II-17 MCD 500 Soft Starter... II-20 General Conditions of Sale and Warranty.... II-26 Freight Options Danfoss offers the following three freight options: 1. Prepay and do not add Eliminates the need for customers to select a carrier and manage separate freight invoices. Danfoss will select a non-expedited, ground carrier. All shipments are F.O.B. point of shipment. VLT AQUA Drives and Standard Panels Models Net price/unit Conditions FLA and demonstration unit amp amp $65 NET 48 adjacent states $110 NET AK, HI, and Canada* $120 NET 48 adjacent states $220 NET AK, HI, and Canada* $550 NET 48 adjacent states $1,100 NET AK, HI, and Canada* Drive accessories (shipped separately from the drive), spare parts Models Net price/package Conditions All bare drives, accessories and parts Drives with standard option panels $20 NET 48 adjacent states packages $40 NET AK, HI, and Canada* $65 NET 48 adjacent states $110 NET AK, HI, and Canada* Danfoss will package multiple parts and accessories in a single package when possible. * Customs broker fees for Canada: $50 per shipment, G.S.T. additional. Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a broker and handle the brokerage fees directly. 2. Collect The customer is responsible for selecting the carrier and indicating their choice on the purchase order. Danfoss will schedule the pick-up. The customer is responsible for paying the carrier for the shipment. 3. Prepay and add Available for the following shipments: Expedited shipments Products such as custom panels and others not listed above Bulk shipments of spare parts Shipment to regions other than those listed above Shipments that require specialized packaging or transport types The customer may select a carrier or allow Danfoss to make the selection. Danfoss will pay the freight at the time of shipment and invoice the customer separately at the time of invoicing from the carrier. Designations: All prices are factory list prices in US$ = Not available nc = Standard, no charge General Policy Information All orders are subject to a minimum billing of $100 NET. For information and Discount Schedule, please contact your Danfoss Representative or the factory. Prices are subject to change without notice. Danfoss reserves the right to select the freight carrier unless specified by the customer. 2 October 2012

3 VLT AQUA Drive To order a drive: Custom configured drives are specified with a discrete alpha-numeric typecode that designates all the performance features and functions of the selected drive. If an appropriately sized drive for the application has not been determined, use the Performance Data selection charts. Factors for this selection include: Supply voltage (VAC) Output power (HP or kw) Current output and input Enclosure type and frame size Once the appropriately sized drive has been determined, use the chart on the following page and on the applicable frame size page to build the the typecode that designates the specific features and functions desired. Frame Size Page A1, A2, A3, A4, A5 10 B1, B2, B3. B4 12 C1, C2, C3, C4 14 D1h, D2h, D3h, D4h 20 E1, E2 22 F1, F2, F3, F4 23 (Note: Once the order and typecode are received by Danfoss, an eight-digit number will be assigned to the requested configuration. Future orders for the same drive configuration can be made using this eight-digit number. To view this eight-digit number on any VLT AQUA Drive, simply display parameter on the LCP or using MCT 10 software.) Every slot is a placeholder for an option. Failure to supply all necessary information in the typecode could delay processing of your order. [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] FC X - G X - X - SXXX - X CX - - XX - Note: custom configured drive pricing in the chart below is for A-E frames only. Consult factory for all F frame pricing.) [1] Performance Level 202 VLT AQUA Drive [2] Power Size PK25 P1M HP (0.25 kw) 1400 kw (690 V only) [3] AC Line Voltage S2 1Ø 200/240 VAC S4 1Ø 380/480 VAC T2 3Ø 200/240 VAC T4 3Ø 380/480 VAC T6 3Ø 525/600 VAC T7 3Ø 525/690 VAC [4] Enclosure C00 Corrosion resistant chassis/ip00 E20 Protected chassis/ip20 E/P21 NEMA 1/IP21 E54 NEMA 12/IP54 E/P/Y/Z55 NEMA 12/IP55 E/Y/Z66 NEMA 4X/IP66 [5] RFI Filter H1/4 Integral class A1 and B1 RFI H2 Integral class A2 RFI Standard HX No Filter Installed (T6 Voltage Only) H5 Maritime Filter H3 Integral class A1 and B1 RFI Refer to specific frame size pages for selection, availability, & pricing [6] Braking X No brake IGBT Installed B Brake IGBT Installed R Regen Terminals (E Frame Only T Safe Stop Terminal Added U Brake IGBT installed with Safe Stoop Terminal Added [7] HMI Adder Price G Graphic LCP installed nc [8] Conformal Coating FC202 PCB s are always coated - the degree of protection is as described below X C Standard 3C2 Conformal Coating Upgraded 3C3 Conformal Coating [9] Mains Input X No Option Installed 3 Drive Fused Disconnect 4 Mains Contactor & Drive Fuses 7 Drive Fuses only A D E J Drive Fuses with Loadsharing Terminals Loadsharing Terminals Mains Disconnect, Contactor & Drive Fuses Circuit Breaker & Drive Fuses [14] Fieldbus Price AX No Fieldbus Option Installed nc A0 Profibus RT MCA101 Option $175 Card A4 DeviceNet MCA104 Option Card $135 AL Profinet MCA120 Option Card $360 AN Ethernet IP MCA121 Option $360 Card AQ Modbus TCP/IP MCA122 Option Card $360 [15] Application Option Price BX No application option nc B0 Analog I/O + RTC Battery $225 Backup MCB 109 B4 VLT Sensor Input MCB114 $140 Option Card BK General Purpose I/O MCB101 $115 Option Card BP Relay Expansion MCB105 $125 Option Card BY Extended Cascade Control with MCO 101 Option Card $995 [17] Motion Control Output Price X No motion control output nc option 5 Advanced Cascade Control with MCO102 Option Card $1,495 [19] Voltage Input Price DX No DC Input Option Installed nc D0 24 Vdc MCB107 Option Card $75 October

4 VLT AQUA Drive VLT AQUA Drives are available in numerous enclosure frame sizes illustrated at right and in several power ranges shown in the charts on the following pages. Single Phase VAC Output power HP Output Current Amps Continuous Output Power kva Input Current Amps Estimated Power loss at max load Watts Output Frequency Max Fuse Size Amps Weight lbs. Chassis NEMA 1 1 1/ FC-202-P1K1-S2 A3 A3+ A5 A FC-202-P1K5-S2 n/a B1 B1 B FC-202-P2K2-S2 n/a B1 B1 B FC-202-P3K0-S2 n/a B1 B1 B FC-202-P4K0-S2 n/a B1 B1 B1 Hz FC-202-P5K5-S2 n/a B1 B1 B FC-202-P7K5-S2 n/a B2 B2 B FC-202-P15K-S2 n/a C1 C1 C FC-202-P22K-S2 n/a C2 C2 C2 Three Phase VAC Output power HP Output Current Amps Continuous Output Power kva Input Current Amps Estimated Power loss at max load Watts Continuous Intermittent Continuoumittent Inter- 1/ Output Frequency Max Fuse Size Amps Weight lbs. NEMA 12/4X Part Number Beginning Part Number Beginning Protected Chassis/IP20 Protected Chassis/IP20 NEMA 1/IP21 NEMA 1/IP21 NEMA 12/ IP55 NEMA 12/ IP55 NEMA 4X/IP66 NEMA 4X/IP66 Chassis NEMA 1 NEMA 12/4X FC-202-PK25-T2 A2 A2+ A4* A4* 1/ FC-202-PK37-T2 A2 A2+ A4* A4* 3/ FC-202-PK55-T2 A2 A2+ A4* A4* FC-202-PK75-T2 A2 A2+ A4* A4* FC-202-P1K1-T2 A2 A2+ A4* A4* FC-202-P1K5-T2 A2 A2+ A4* A4* FC-202-P2K2-T2 A2 A2+ A4* A4* FC-202-P3K0-T2 A3 A3+ A5 A / Hz FC-202-P3K7-T2 FC-202-P5K5-T2 A3 B3 A3+ B1 A5 B1 A5 B FC-202-P7K5-T2 B3 B1 B1 B FC-202-P11K-T2 B3 B1 B1 B FC-202-P15K-T2 B4 B2 B2 B FC-202-P18K-T2 B4 C1 C1 C FC-202-P22K-T2 C3 C1 C1 C FC-202-P30K-T2 C3 C1 C1 C FC-202-P37K-T2 C4 C2 C2 C FC-202-P45K-T2 C4 C2 C2 C2 * if integral Fuses or Fused Disconnect are ordered then the frame will be A5 + includes Nema 1 Kit 4 October 2012

5 VLT AQUA Drive Single Phase VAC Output power HP Output Current Amps Continuous Output Power kva Input Current Amps Estimated Power loss at max load Watts Output Frequency Max Fuse Size Amps Continuous Intermittent Chassis NEMA 1 NEMA 12/4X FC-202-P7K5-S4 n/a B1 B1 B FC-202-P11K-S4 n/a B2 B2 B Hz FC-202-P18K-S4 n/a C1 C1 C FC-202-P37K-S4 n/a C2 C2 C2 Three Phase VAC Output power HP Output Current Amps Continuous Output Power kva Input Current Amps Estimated Power loss at max load Watts Output Frequency Max Fuse Size Amps Continuoumittent 12/4X Inter- NEMA Chassis NEMA 1 1/ FC-202-PK37-T4 A2 A2+ A4* A4* 3/ FC-202-PK55-T4 A2 A2+ A4* A4* FC-202-PK75-T4 A2 A2+ A4* A4* FC-202-P1K1-T4 A2 A2+ A4* A4* FC-202-P1K5-T4 A2 A2+ A4* A4* FC-202-P2K2-T4 A2 A2+ A4* A4* FC-202-P3K0-T4 A2 A2+ A4* A4* FC-202-P4K0-T4 A2 A2+ A4* A4* 7 1/ FC-202-P5K5-T4 A3 A3+ A5 A Hz FC-202-P7K5-T4 A3 A3+ A5 A FC-202-P11K-T4 B3 B1 B1 B FC-202-P15K-T4 B3 B1 B1 B FC-202-P18K-T4 B3 B1 B1 B FC-202-P22K-T4 B4 B2 B2 B FC-202-P30K-T4 B4 B2 B2 B FC-202-P37K-T4 B4 C1 C1 C FC-202-P45K-T4 C3 C1 C1 C FC-202-P55K-T4 C3 C1 C1 C FC-202-P75K-T4 C4 C2 C2 C FC-202-P90K-T4 C4 C2 C2 C2 * if integral Fuses or Fused Disconnect are ordered then the frame will be A5. A2+ includes NEMA 1 Kit. A3+ includes NEMA 1 Kit. VLT AQUA Drive (FC 202) VAC Output power HP Output Current Amps Output Power kva Input Current Amps Estimated Power loss at max load Watts Output Frequency Max External Input Mains Fuses Amps Continuous Intermittent Continuous Intermittent Chassis NEMA 1 NEMA 12 Chassis NEMA 1 NEMA FC-202N110T4 D3h D1h D1h FC-202N132T4 D3h D1h D1h FC-202N160T4 D4h D2h D2h FC-202N200T4 D4h D2h D2h FC-202N250T4 D4h D2h D2h FC-202P315T4 E2 E1 E FC-202P355T4 E2 E1 E FC-202P400T4 E2 E1 E1 Hz FC-202P450T4 E2 E1 E FC-202P500T4 F1/F3 F1/F FC-202P560T4 F1/F3 F1/F FC-202P630T4 F1/F3 F1/F3 n/a FC-202P710T4 F1/F3 F1/F FC-202P800T4 F2/F4 F2/F FC-202P1M0T4 F2/F4 F2/F4 Weight lbs. Weight lbs. Weight lbs. Part Number Beginning Part Number Beginning Part Number Beginning Protected Chassis/IP20 Protected Chassis/IP20 NEMA 1/IP21 NEMA 1/IP21 NEMA 12/IP55 NEMA 12/IP55 VLT 6-Pulse NEMA 4X/IP66 NEMA 4X/IP66 October

6 VLT AQUA Drive Performance Data VLT AQUA Drive (FC 202) 600 V Motor Nominal Voltage 575 VAC Output power HP Output Current Amps Continuous Output Power kva Input Current Amps Estimated Power loss at max load Watts Output Frequency Max Fuse Size Amps Continuoumittent 12/4X 12/4X Inter- NEMA NEMA Chassis NEMA 1 Chassis NEMA FC-202-PK75-T6 A2 A2+ A FC-202-P1K1-T6 A2 A2+ A FC-202-P1K5-T6 A2 A2+ A FC-202-P2K2-T6 A2 A2+ A FC-202-P3K0-T6 A2 A2+ A FC-202-P4K0-T6 A2 A2+ A FC-202-P5K5-T6 A3 A3+ A FC-202-P7K5-T6 A3 A3+ A FC-202-P11K-T6 B3 B1 B Hz FC-202-P15K-T6 B3 B1 B FC-202-P18K-T6 B3 B1 B FC-202-P22K-T6 B4 B2 B FC-202-P30K-T6 B4 B2 B FC-202-P37K-T6 B4 B2 B FC-202-P45K-T6 C3 C1 C FC-202-P55K-T6 C3 C1 C FC-202-P75K-T6 C4 C2 C FC-202-P90K-T6 C4 C2 C2 Weight lbs. Part Number Beginning VLT 6-Pulse VLT AQUA Drive (FC 202) 575 V Motor Nominal Voltage VAC Output power HP Output Current Amps Output Power kva Input Current Amps Estimated Power loss at max load Watts Output Frequency Max External Input Mains Fuses Amps Continuoumittentinuoumittent Inter- Con- Inter- Chassis NEMA 1 NEMA 12 Chassis NEMA 1 NEMA FC-202N110T7 D3h D1h D1h FC-202N132T7 D3h D1h D1h FC-202N160T7 D3h D1h D1h FC-202N200T7 D4h D2h D2h FC-202N250T7 D4h D2h D2h FC-202N315T7 D4h D2h D2h FC-202N400T7 D4h D2h D2h FC-202P450T7 E2 E1 E FC-202P500T7 E2 E1 E Hz FC-202P560T7 E2 E1 E FC-202P630T7 E2 E1 E for FC-202P710T7 F1/F3 F1/F P710, 2214 FC-202P800T7 F1/F3 F1/F3 P800, P900 FC-202P900T7 F1/F3 F1/F for 2748 FC-202P1M0T7 F2/F4 F2/F P1M2 and FC-202P1M2T7 F2/F4 F2/F P1M4 FC-202P1M4T7 F2/F4 F2/F4 Weight lbs. Part Number Beginning VLT 6-Pulse 6 October 2012

7 VLT AQUA Drive Performance Data VLT AQUA Drive (FC 202) 690 V Motor Nominal Voltage VAC Output power kw Output Current Amps Output Power kva Input Current Amps Estimated Power loss at max load Watts Output Frequency Max External Input Mains Fuses Amps Continuoumittentinuoumittent Inter- Con- Inter- Chassis NEMA 1 NEMA 12 Chassis NEMA 1 NEMA FC-202N110T7 D3h D1h D1h FC-202N132T7 D3h D1h D1h FC-202N160T7 D3h D1h D1h FC-202N200T7 D4h D2h D2h FC-202N250T7 D4h D2h D2h FC-202N315T7 D4h D2h D2h FC-202N400T7 D4h D2h D2h FC-202P450T7 E2 E1 E FC-202P500T7 E2 E1 E1 Hz FC-202P560T7 E2 E1 E FC-202P630T7 E2 E1 E n/a FC-202P710T7 F1/F3 F1/F FC-202P800T7 F1/F3 F1/F FC-202P900T7 F1/F3 F1/F FC-202P1M0T7 F2/F4 F2/F FC-202P1M2T7 F2/F4 F2/F FC-202P1M4T7 F2/F4 F2/F4 Weight lbs. Part Number Beginning VLT 6-Pulse October

8 VLT AQUA Drive (Single Phase Input) 240V Single Phase ( V) [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] FC S X - G X - X - SXXX - X CX - - XX - Frame Power ADDITIONAL PRICES HP kw Enclosure Hardware FLA FC 202 BASIC RFI NEMA NEMA IP20 NEMA 1 LCP PRICE 12 4X Coating 110% Chassis /IP21 A1 / B1 A2 Graphical /IP55 /IP66 Mains Disconnect E20 E21 E55 E66 HX H1 H2 H3 G X C 1 O A3/A P1K1 $850 std $60 $150 $365 N/A $120 std $85 $ P1K5 $935 N/A std $370 $620 N/A $135 std $95 $ P2K2 $1,250 N/A std $370 $620 N/A $150 std $110 $295 B P3K0 $1,375 N/A std $370 $620 N/A $280 std $210 $295 $ P3K7 $1,490 N/A std $370 $620 N/A $290 std $225 Included NC $150 $ P5K5 $1,625 N/A std $370 $620 N/A $330 std $275 $295 B P7K5 $1,999 N/A std $510 $850 std N/A N/A N/A $295 C P15K $4,075 N/A std $765 $1,375 std N/A N/A N/A $435 N/A C P22K $5,850 N/A std $1,000 $1,795 std N/A N/A N/A $660 N/A Metric Thread Cable Entries [5] RFI Filter H1/4 Integral class A1 and B1 RFI H2 Integral class A2 RFI Standard HX No Filter Installed H3 Integral class A1 and B1 RFI [8] Conformal Coating FC202 PCB s are always coated - the degree of protection is as described below X Standard 3C2 Conformal Coating C Upgraded 3C3 Conformal Coating [15] Application Option Price BX No application option nc B4 PTC Sensor Input MCB 114 $140 BO Analog IO + battery backup MCB109 $225 BK General purpose I/O MCB BY Extended cascade control 100 BP Relay expansion MCB [19] Voltage Input Price DX No DC input nc D0 24 VDC option MCB107 $100 [14] Fieldbus Price AX No fieldbus nc A0 Profibus MCA101 $275 A4 DeviceNet MCA AN Ethernet IP MCA AQ Modbus TCP/IP MCA AL Profinet October 2012

9 VLT AQUA Drive (Single Phase Input) 480V Single Phase ( V) [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] FC S X - G X - X - SXXX - X CX - - XX - Frame Power ADDITIONAL PRICES HP kw Enclosure Hardware RFI BASIC NEMA NEMA FLA FC 202 IP20 NEMA 1 LCP PRICE 12 4X Coating 110% Chassis /IP21 A1 / B1 A2 Graphical /IP55 /IP66 Mains Disconnect E20 E21 E55 E66 HX H1 H2 H3 G X C 1 O B P7K5 $2,010 N/A std $370 $620 N/A $290 std $225 $315 $25 B P11K $3,025 N/A std $510 $850 N/A $375 std $310 $315 Included NC $150 C P18K $4,550 N/A std $765 $1,375 std N/A N/A N/A $460 N/A C P37K $7,625 N/A std $1,000 $1,795 std N/A N/A N/A $700 N/A Metric Thread Cable Entries [5] RFI Filter H1/4 Integral class A1 and B1 RFI H2 Integral class A2 RFI Standard HX No Filter Installed H3 Integral class A1 and B1 RFI [8] Conformal Coating FC202 PCB s are always coated - the degree of protection is as described below X Standard 3C2 Conformal Coating C Upgraded 3C3 Conformal Coating [14] Fieldbus Price AX No fieldbus nc A0 Profibus MCA101 $275 A4 DeviceNet MCA AN Ethernet IP MCA AQ Modbus TCP/IP MCA AL Profinet 435 [15] Application Option Price BX No application option nc B4 PTC Sensor Input MCB 114 $140 BO Analog IO + battery backup MCB109 $225 BK General purpose I/O MCB BY Extended cascade control 100 BP Relay expansion MCB [19] Voltage Input Price DX No DC input nc D0 24 VDC option MCB107 $100 October

10 VLT AQUA Drive A1 A2 A3 A4 A5 A Frame Sizes FC 202 Use the Performance Data Selection charts on pages 4-6 to determine the frame size and enclosure style availability for the selected Power Size [2]. [1] [2] [3] [4] [5] [6] [7] [8] [9] [10]* [11] [12] [13] [14] [15] [16] [17] [18] [19] FC X - G X - X - SXXX - X CX - - XX VAC - T VAC - T4 E20 with [2] [4] Enclosure Options [5] RFI Options Graphic LCP Size HP FLA Frame Base E20 E21 Frame E55 E66 P55 Frame Y55 Z55 Y66 Z66 H1 H2 H3 1/3 1.8 PK25 A2 $559 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $50 nc $35 1/2 2.4 PK37 A2 $583 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $55 nc $35 3/4 3.5 PK55 A2 $600 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $60 nc $ PK75 A2 $613 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $70 nc $50 1-1/2 6.6 P1K1 A2 $655 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $80 nc $ P1K5 A2 $698 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $95 nc $ P2K2 A2 $772 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $115 nc $ P3K0 A3 $850 nc $60 A5 $150 $365 $ $130 nc $ P3K7 A3 $928 nc $60 A5 $150 $365 $ $140 nc $105 Brake Option Display Option [8] Coating [9] Mains Input Option HP FLA Size X G X C /3 1.8 PK25 nc $130 $195 $350 $155 1/2 2.4 PK37 nc $130 $195 $350 $155 3/4 3.5 PK55 nc $130 $195 $350 $ PK75 nc $130 $195 $350 $ /2 6.6 P1K1 nc nc nc $130 $195 $350 $ P1K5 nc $130 $195 $350 $ P2K2 nc $130 $195 $350 $ P3K0 nc $130 $195 $350 $ P3K7 nc $130 $195 $350 $155 E20 with [2] [4] Enclosure Options [5] RFI Options Graphic LCP Size HP FLA Frame Base E20 E21 Frame E55 E66 P55 Frame Y55 Z55 Y66 Z66 H1 H2 H3 1/2 1.2 PK37 A2 $583 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $55 nc $35 3/4 1.6 PK55 A2 $633 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $60 nc $ PK75 A2 $682 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $70 nc $50 1-1/2 2.7 P1K1 A2 $735 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $80 nc $ P1K5 A2 $789 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $95 nc $ P2K2 A2 $846 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $115 nc $ P3K0 A2 $925 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $130 nc $ P4K0 A2 $955 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $140 nc $ / P5K5 A3 $1,097 nc $60 A5 $150 $365 $ $165 nc $ P7K5 A3 $1,252 nc $60 A5 $150 $365 $ $195 nc $140 Brake Option Display Option [8] Coating [9] Mains Input Option HP FLA Size X G X C /2 1.2 PK37 nc $130 $195 $350 $155 3/4 1.6 PK55 nc $130 $195 $350 $ PK75 nc $130 $195 $350 $ /2 2.7 P1K1 nc $130 $195 $350 $ P1K5 nc $130 $195 $350 $ P2K2 nc nc nc $130 $195 $350 $ P3K0 nc $130 $195 $350 $ P4K0 nc $130 $195 $350 $ / P5K5 nc $130 $195 $350 $ P7K5 nc $130 $195 $350 $155 For Common Options see page October 2012

11 VLT AQUA Drive A1 A2 A3 A5 A Frame Sizes FC 202 Use the Performance Data Selection charts on pages 4-6 to determine the frame size and enclosure style availability for the selected Power Size [2] VAC - T6 E20 with [2] [4] Enclosure Options [5] RFI Options Graphic LCP Size HP FLA Frame Base E20 E21 Frame E55 E66 P55 Frame HX H2 H PK75 A3 $723 nc $60 A5 $150 $365 $170 - nc /2 2.4 P1K1 A3 $753 nc $60 A5 $150 $365 $170 - nc P1K5 A3 $813 nc $60 A5 $150 $365 $170 - nc P2K2 A3 $895 nc $60 A5 $150 $365 $170 - nc P3K0 A3 $995 nc $60 A5 $150 $365 $170 - nc P4K0 A2 $1,055 nc $60 A5 $150 $365 $170 - nc /2 9.0 P5K5 A3 $1,225 nc $60 A5 $150 $365 $170 - nc P7K5 A3 $1,375 nc $60 A5 $150 $365 $170 - nc - - Brake Option Display Option [8] Coating [9] Mains input HP FLA Size X B T U G X C PK75 nc $50 $30 $80 nc $130 $195 $350 $ /2 2.4 P1K1 nc $55 $30 $85 nc $130 $195 $350 $ P1K5 nc $70 $35 $105 nc $130 $195 $350 $ P2K2 nc $85 $45 $130 nc $130 $195 $350 $155 nc P3K0 nc $95 $50 $145 nc $130 $195 $350 $ P4K0 nc $105 $55 $160 nc $130 $195 $350 $ /2 9.0 P5K5 nc $120 $65 $185 nc $130 $195 $350 $ P7K5 nc $140 $70 $210 nc $130 $195 $350 $155 [1] Performance Level 202 AQUA Drive [2] Power Size (1) PK HP (0.25 kw) PK HP (0.37 kw) PK HP (0.55 kw) PK75 1 HP (0.75 kw) P1K1 1.5 HP (1.1 kw) P1K5 2 HP (1.5 kw) P2K2 3 HP (2.2 kw) P3K7 5 HP (3.7 kw) ( VAC only) P4K0 5 HP (4 kw) ( VAC only) P5K5 7.5 HP (5.5 kw) P7K5 10 HP (7.5 kw) [3] AC Line Voltage T2 3Ø VAC T4 3Ø VAC T6 3Ø VAC [4] Enclosure E20 Protected chassis/ip20 E21 NEMA 1/IP21 E55 NEMA 12/IP55 E66 NEMA 4X/IP66 P55 NEMA 12/IP55 with backplate Y55 Z55 Y66 NEMA 12/IP55 with backplate (A4 only) NEMA 12/IP55 (A4 only) NEMA 4X/IP66 with backplate (A4 only) Z66 NEMA 4X/IP66 (A4 only) [5] RFI Filter H1 Integral class A1 and B1 RFI filter H2 Integral class A2 RFI filter H3 Integral class A1 and B1 RFI filter HX None (T6 only) [6] Braking X No brake IGBT B Brake IGBT mounted (resistor sold separately T Safe stop terminal U Safe stop with brake [8] Conformal Coating FC202 PCB s are always coated - the degree of protection is as described below X Standard 3C2 Conformal Coating C Upgraded 3C3 Conformal Coating [9] Mains Input (1) X No option 1 Mains disconnect 3 Mains disconnect and drive fuses 7 Drive fueses *[10] Select S when using A5 or A4 enclosure. (1) Mains Input options not available E20 enclosures select X. For Common Options see page 3. October

12 VLT AQUA Drive B1 B2 B3 B4 B Frame Sizes FC 202 Use the Performance Data Selection charts on pages 4-6 to determine the frame size and enclosure style availability for the selected Power Size [2]. [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] FC X - G X - X - SXXX - X CX - - XX VAC - T VAC - T VAC - T6 E20 w [2] [4] Enclosure Options [5] RFI Option Brake Option Graphic LCP Size HP FLA Frame Base E20 P20 Frame E21 E55 E66 P21 P55 H1 H2 H3 X B T U 7-1/ P5K5 B3 $1,165 nc - B1 $250 $370 $620 $270 $390 $265 nc $200 nc $120 $80 $ P7K5 B3 $1,325 nc - B1 $250 $370 $620 $270 $390 $275 nc $210 nc $140 $95 $ P11K B3 $1,480 nc - B1 $250 $370 $620 $270 $390 $315 nc $255 nc $170 $120 $ P15K B4 $1,826 nc $30 B2 $340 $510 $850 $370 $540 $405 nc $350 nc $190 $165 $355 Display Option [8] Coating [9] Mains Input Option HP FLA Size G X C X A D 7-1/ P5K5 nc $130 nc $295 $460 $580 $165 $415 $285 $ P7K5 nc $130 nc $295 $460 $600 $165 $435 $305 $140 nc P11K nc $130 nc $295 $460 $610 $165 $445 $315 $ P15K nc $130 nc $295 $580 $765 $285 $480 $470 $185 E20 w [2] [4] Enclosure Options [5] RFI Option Brake Option Graphic LCP Size HP FLA Frame Base E20 P20 Frame E21 E55 E66 P21 P55 H1 H2 H3 X P11K B3 $1,499 nc - B1 $250 $370 $620 $270 $390 $265 nc $ P15K B3 $1,834 nc - B1 $250 $370 $620 $270 $390 $275 nc $ P18K B3 $2,339 nc - B1 $250 $370 $620 $270 $390 $315 nc $255 nc P22K B4 $2,750 nc $30 B2 $340 $510 $850 $370 $540 $355 nc $ P30K B4 $3,413 nc $30 B2 $340 $510 $850 $370 $540 $405 nc $350 Display Option [8] Coating [9] Mains Input Option HP FLA Size G X C X A D P11K nc $130 nc $295 $460 $580 $165 $415 $285 $ P15K nc $130 nc $295 $460 $600 $165 $435 $305 $ P18K nc nc $130 nc $295 $460 $610 $165 $445 $315 $ P22K nc $130 nc $295 $495 $670 $200 $470 $375 $ P30K nc $130 nc $295 $580 $765 $285 $480 $470 $185 E20 w [2] [4] Enclosure Options [5] RFI Options Brake Option Graphic LCP Size HP FLA Frame Base E20 P20 Frame E21 E55 E66 P21 P55 HX H2 H3 X P11K B3 $1,739 nc - B1 $250 $370 $620 $270 $390 nc P15K B3 $2,175 nc - B1 $250 $370 $620 $270 $390 nc P18K B3 $2,823 nc - B1 $250 $370 $620 $270 $390 nc P22K B4 $3,340 nc $30 B2 $340 $510 $850 $370 $540 nc - - nc P30K B4 $4,049 nc $30 B2 $340 $510 $850 $370 $540 nc P37K B4 $5,111 nc $30 B2 $340 $510 $850 $370 $540 nc - - Display Option [8] Coating [9] Mains Input Option HP FLA Size G X C X A D P11K nc $130 nc $295 $460 $580 $165 $415 $285 $ P15K nc $130 nc $295 $460 $600 $165 $435 $305 $ P18K nc $130 nc $295 $460 $610 $165 $445 $315 $150 nc P22K nc $130 nc $295 $495 $670 $200 $470 $375 $ P30K nc $130 nc $295 $540 $725 $245 $480 $430 $ P37K nc $130 nc $435 $720 $930 $285 $645 $495 $210 For Common Options see page October 2012

13 VLT AQUA Drive B1 B2 B3 B4 B Frame Sizes FC 202 Use the Performance Data Selection charts on pages 4-6 to determine the frame size and enclosure style availability for the selected Power Size [2] VAC - T7 E21 w [2] [4] Enclosure Options [5] RFI Options Brake Option Graphic LCP Size kw FLA Frame Base E20 P20 Frame E21 E55 E66 P21 P55 H2 H4 H5 X P11K B2 $2, B2 nc $170 - $30 $200 nc $530 $ P15K B2 $2, B2 nc $170 - $30 $200 nc $545 $ P18K B2 $3, B2 nc $170 - $30 $200 nc $625 $190 nc P22K B2 $3, B2 nc $170 - $30 $200 nc $705 $ P30K B2 $4, B2 nc $170 - $30 $200 nc $810 $245 Display Option [8] Coating [9] Mains Input Option kw FLA Size G X C X A D P11K - nc nc $ $520 - $ P15K - nc nc $ $530 - $ P18K nc - nc nc $ $535 - $ P22K - nc nc $ $550 - $ P30K - nc nc $ $555 - $260 [1] Performance Level 322 AQUA Drive [2] Power Size P5K5 7.5 HP (5.5 kw) P7K5 10 HP (7.5 kw) P11K 15 HP (11 kw) P15K 20 HP (15 kw) P18K 25 HP (18 kw) P22K 30 HP (22 kw) P30K 40 HP (30kW) P37K 50 HP (37 kw) [3] AC Line Voltage T2 3Ø VAC T4 3Ø VAC T6 3Ø VAC T7 3Ø VAC [4] Enclosure E20 Protected chassis/ip20 E21 NEMA 1/IP21 E55 NEMA 12/IP55 E66 NEMA 4X/IP66 P20 Protected chassis/ip20 with backplate P21 NEMA 1/IP21 with backplate P55 NEMA 12/IP55 with backplate [5] RFI Filter H1 Integral class A1 and B1 RFI filter H2 Integral class A2 RFI filter H3 H4 H5 HX Integral class A1 and B1 RFI filter Integral class A1 and B1 RFI filter Maritime Filter (690 V only) None (T6 only) [6] Braking X No brake IGBT B Brake IGBT mounted (resistor sold separately T Safe stop terminal U Safe stop with brake [8] Conformal Coating FC202 PCB s are always coated - the degree of protection is as described below X Standard 3C2 Conformal Coating C Upgraded 3C3 Conformal Coating [9] Mains Input (1) X No option 1 Mains disconnect 3 Mains disconnect and drive fuses 5 Mains disconnect, drive fuses and loadsharing 7 Drive fuses 8 Mains disconnect and loadsharing A Drive fuses and loadsharing D Loadsharing terminals (1) Mains Input options not available E20 enclosures select X. For Common Options see page 3. October

14 VLT AQUA Drive C1 C2 C3 C4 C Frame Sizes FC 202 Use the Performance Data Selection charts on pages 4-6 to determine the frame size and enclosure style availability for the selected Power Size [2]. [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] FC X - G X - X - SXXX - X CX - - XX VAC - T VAC - T4 E20 w [2] [4] Enclosure Options [5] RFI Option Brake Option Graphic LCP Size HP FLA Frame Base E20 P20 Frame E21 E55 E66 P21 P55 H1 H2 H3 X P18K B4 $2,341 nc $35 C1 $615 $765 $1,375 $650 $800 $415 nc $ P22K C3 $2,948 nc $35 C1 $615 $765 $1,375 $650 $800 $495 nc $ P30K C3 $3,717 nc $35 C1 $615 $765 $1,375 $650 $800 $670 nc $595 nc P37K C4 $4,559 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 $885 nc $ P45K C4 $5,317 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 $990 nc $905 Display Option [8] Coating [9] Mains Input Option HP FLA Size G X C X A D P18K nc $255 nc $435 $910 $1,120 $475 $645 $685 $ P22K nc $255 nc $435 $910 $1,130 $475 $655 $695 $ P30K nc nc $255 nc $435 $1,000 $1,255 $565 $690 $820 $ P37K nc $255 nc $660 $1,305 - $ $ P45K nc $255 nc $660 $1,625 - $ $335 E20 w [2] [4] Enclosure Options [5] RFI Option Brake Option Graphic LCP Size HP FLA Frame Bae E20 P20 Frame E21 E55 E66 P21 P55 H1 H2 H3 X B T U P37K B4 $4,135 nc $35 C1 $615 $765 $1,375 $650 $800 $415 nc $365 nc $390 $200 $ P45K C3 $4,852 nc $35 C1 $615 $765 $1,375 $650 $800 $495 nc $440 nc $480 $245 $ P55K C3 $5,765 nc $35 C1 $615 $765 $1,375 $650 $800 $670 nc $595 nc $575 $295 $ P75K C4 $6,934 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 $885 nc $800 nc $655 $335 $ P90K C4 $8,365 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 $990 nc $905 nc $750 $400 $1,150 Display Option [8] Coating [9] Mains Input Option HP FLA Size G X C X A D P37K nc $255 nc $435 $910 $1,120 $475 $645 $685 $ P45K nc $255 nc $435 $910 $1,130 $475 $655 $695 $ P55K nc nc $255 nc $435 $1,000 $1,255 $565 $690 $820 $ P75K nc $255 nc $660 $1,305 - $ $ P90K nc $255 nc $660 $1,625 - $ $335 For Common Options see page October 2012

15 VLT AQUA Drive C1 C2 C3 C4 C Frame Sizes FC 202 Use the Performance Data Selection charts on pages 4-6 to determine the frame size and enclosure style availability for the selected Power Size [2] VAC - T VAC - T7 E20 w [2] [4] Enclosure Options [5] RFI Option Brake Option Graphic LCP Size HP FLA Size Base E20 P20 Frame E21 E55 E66 P21 P55 HX H2 H3 X P45K C3 $6,001 nc $35 C1 $615 $765 $1,375 $650 $800 nc P55K C3 $6,732 nc $35 C1 $615 $765 $1,375 $650 $800 nc - - nc P75K C4 $8,162 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 nc P90K C4 $9,806 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 nc - - Display Option [8] Coating [9]Mains Input Option HP FLA Size G X C X A D P45K nc $255 nc $435 $910 $1,130 $475 $655 $695 $ P55K nc $255 nc $435 $1,000 $1,255 $565 $690 $820 $255 nc P75K nc $255 nc $660 $1,305 $ $ P90K nc $255 nc $660 $1,625 $ $335 E20 w [2] [4] Enclosure Options [5] RFI Options Brake Option Graphic LCP Size kw FLA Frame Base E20 P20 Frame E21 E55 E66 P21 P55 H2 H4 H5 X P37K C2 $5, C2 nc $200 - $35 $235 nc $840 $ P45K C2 $6, C2 nc $200 - $35 $235 nc $960 $ P55K C2 $8, C2 nc $200 - $35 $235 nc $1,055 $330 nc P75K C2 $8, C2 nc $200 - $35 $235 nc $1,175 $ P90K C2 $9, C2 nc $200 - $35 $235 nc $1,310 $395 Display Option [8] Coating [9] Mains Input Option kw FLA Size G X C X A D P37K - nc nc $ P45K - nc nc $ P55K nc - nc nc $ P75K - nc nc $1, P90K - nc nc $1, [1] Performance Level 322 AQUA Drive [2] Power Size P18K 25 HP (18 kw) P22K 30 HP (22 kw) P30K 40 HP (30 kw) P37K 50 HP (37 kw) P45K 60 HP (45 kw) P55K 75 HP (55 kw) P75K 100 HP (75 kw) P90K 125 HP (90 kw) [3] AC Line Voltage T2 3Ø VAC T4 3Ø VAC T6 3Ø VAC T7 3Ø VAC (1) Mains Input options not available E20 select X. For Common Options see page 3. [4] Enclosure E20 Protected chassis/ip20 E21 NEMA 1/IP21 E55 NEMA 12/IP55 E66 NEMA 4X/IP66 P20 Protected chassis/ip20 with backplate P21 NEMA 1/IP21 with backplate P55 NEMA 12/IP55 with backplate [5] RFI Filter H1 Integral class A1 and B1 RFI filter H2 Integral class A2 RFI filter H3 H4 HX Integral class A1 and B1 RFI filter Integral class A1 and B1 RFI filter None (T6 only) [6] Braking X No brake IGBT B Brake IGBT mounted (resistor sold separately T Safe stop terminal U Safe stop with brake [8] Conformal Coating FC202 PCB s are always coated - the degree of protection is as described below X Standard 3C2 Conformal Coating C Upgraded 3C3 Conformal Coating [9] Mains Input (1) X No option 1 Mains disconnect 3 Mains disconnect and drive fuses 5 Mains disconnect, drive fuses and loadsharing 7 Drive fuses 8 Mains disconnect and loadsharing A Drive fuses and loadsharing D Loadsharing terminals October

16 VLT AQUA Drive Panels Danfoss Drives now offers drive bypass and non-bypass panels in two different configurations. The Traditional bypass panels are the legacy product and are available from 0.5 to 350 HP. Danfoss has enhanced this product lineup with Vertical panel designs to appeal to those applications where wall space is a premium. The vertical designs are NEMA / UL Type 1 rated, begin at 7.5 HP and continue to 125 HP, and are available as either non-bypass panels with fuses and disconnects, or in 3 contactor electromechanical or electronic bypass designs. All Danfoss panels included are UL508A listed. Drive with disconnect or fused disconnect The sections that follow describe: Drives with disconnects or fused disconnects Vertical bypass and non-bypass panels and pricing Traditional Bypass panels and pricing (including 3R panels) Drive and panel options and accessories Electro-Mechanically Controlled Bypass panels Drive Drive Motor Motor Traditional bypass panel Vertical bypass panel Drive with Input Disconnect Switch A padlockable, defeatable, two-position rotary switch that allows the input line to the drive to be disconnected. For safety, the switch must be in the OFF position before the enclosure cover can be removed. Includes drive and disconnect switch. For single motor applications only. Drive with Input Disconnect Switch and Input Fuses Includes drive, drive fuses, and disconnect switch. For single motor applications only. The VLT AQUA drive Vertical panel is designed around the FC202 drive and has the same performance as the Traditional panel with a smaller footprint. The sleek vertical layout requires less horizontal wall space than Traditional panels. The units are offered as NEMA / UL Type 1 designs and are UL/cUL 508A listed. The panels have been seismically certified and OSHPD Pre-Approved. The 3 contactor bypass units are priced like 2 contactor panels and are available with 24VDC control in all but the largest sizes minimizing product damage and downtime in adverse power quality installations. Includes back plate if required and graphical control panel. Maximum Drive Output Current rating of drive must always equal or exceed nameplate full-load amps of motor(s). Disconnects and fused disconnects mount below the drive in an extended drive enclosure for all A2 and A3 frame sizes and all Vertical Non-Bypass panels. For all other Traditional panel sizes, disconnect and fuses will mount inside the drive enclosure. No additional enclosure is required. The Vertical panels are designed for VAC up to 60 HP, and for 460 and 575 VAC up to 125 HP. The units can be built with fused disconnect or circuit breaker protection in nonbypass and 3 contactor bypass designs. Panels are available with a 100kA SCCR rating and a multitude of fieldbus and I/O options. 16 October 2012

17 VLT AQUA Drive Panels Vertical Bypass Panel Dimensions Frame NEMA 1 Non- Bypass 208V Bypass 208V Dimensions (inches) HP Range Non-Bypass Tier 1 Bypass tier 2 Non- Bypass 230V Bypass 230V 460V & 600V Height Width Depth Height Width Depth Mechanical Submittal Drawing Number Non Bypass Tier 1 Bypass Tier 2 P2/B3 x R R0201 P3/B4 x R R0203 P4/C3 x R R0205 P5/C4 x R R0207 October 2012 page updated 10/26/

18 VLT AQUA Drive Panels [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] FC X - G X - X - SXXX - X CX - - XX - 200V ( V) BASIC E20 H2 Drive Frame Bypass Frame Power String Code Position HP kw [4] [9] 110% FC 202 IP21 Vert. Panel NEMA 1 Enclosure EMB2+main Disconn. & Drive Fuses EMB2+Main Disc.+Main & Drive Fuses EMB2+CB+ Drive Fuses+ S21 L M N P5K5 $105 $760 $900 $900 B3 P P7K5 $135 $840 $990 $ P11K $175 $865 $1,025 $1,025 B4 P P15K $250 $885 $1,045 $1, P18K $315 $1,120 $1,330 $1,330 C3 P P22K $365 $1,310 $1,550 $1, P30K $405 $2,170 $2,440 $2,440 C4 P P37K $495 $2,635 $2,960 $2, P45K $575 $3,165 $3,560 $3, V ( V) E20 H2 B3 B4 C3 C4 P2 P3 P4 P P11K $105 $760 $900 $ P15K $135 $840 $990 $ P18K $175 $865 $1,025 $1, P22K $205 $875 $1,040 $1, P30K $250 $885 $1,045 $1, P37K $315 $1,120 $1,330 $1, P45K $365 $1,310 $1,550 $1, P55K $405 $2,170 $2,440 $2, P75K $495 $2,635 $2,960 $2, P90K $575 $3,165 $3,650 $3, V* ( V) B3 B4 C3 C4 P2 P3 P4 P P11K $125 $790 $935 $ P15K $165 $875 $1,030 $1, P18K $205 $900 $1,065 $1, P22K $245 $910 $1,080 $1, P30K $300 $920 $1,090 $1, P37K $375 $1,165 $1,380 $1, P45K $450 $1,360 $1,615 $1, P55K $475 $2,255 $2,540 $2, P75K $575 $2,740 $3,080 $3, P90K $675 $3,290 $3,700 $3,700 EMB2 L 3 Contactor Electro Mechanical ByPass with Main Disconnect and Drive Fuses M 3 Contactor Electro Mechanical ByPass with Main Fused Disconnect and Drive Fuses (100 KA SCCR) N 3 Contactor Electro Mechanical ByPass with Main Circuit Breaker and Drive fuses (100 KA SCCR) * 600V Panel Fusing is rated 5 KA SCCR 18 October 2012

19 VLT AQUA Drive Panels For the EMB, an enclosure mounted Drive/OFF/Bypass/Test Selector switch is used to electrically select whether the motor is driven by the drive, connected to the full speed bypass, or disconnected from both. The test position applies power to the motor through the bypass (M3 closed) while removing power to the motor (M2 open) but keeps the drive powered (M1 closed). A Pilot light indicates when in bypass. Contactor Drive Mode Off Bypass Mode Test Mode M1 Closed Open Open Closed M2 Closed Open Open Open M3 Open Open Closed Closed Features of the EMB2 Bypass Configuration The main disconnect removes line input power to the drive and bypass. A main disconnect is available in three options: Main Disconnect with Drive Fuses For user-supplied Circuit Breaker or fuses for bypass operation of motor Main Fused disconnect with Main and Drive Fuses Two-position (ON/OFF) rotary switch, padlock compatible, with three fuses, one on each phase, built into the switch. For safety, the switch must be in the OFF position before the option panel door can be opened. Main circuit breaker with Drive Fuses A thermal/ magnetic current interrupt device using an ON/ TRIP/OFF/RESET switch. When in the ON position, a trip fault removes power from the drive/bypass circuit and the switch moves to the TRIP setting. It must be moved to the RESET position momentarily after the fault has been cleared to reset the circuit breaker. Standard Control Features Common Run/Stop with Bypass Allows a common remote signal through the VFD input terminals to initiate operation in either drive control or bypass. A relay closure starts the motor(s) in drive or bypass, depending upon the position of the bypass selector switch. Automatic Bypass Automatically transfers the motor(s) from drive to bypass without operator intervention when a fault condition trips the drive, after a programmable time-out period. The VFD s internal fault circuitry controls this action. The time delay permits all automatically resettable faults to clear prior to transfer to bypass. Run permissive or safety circuit signals override the auto bypass function and may prevent or delay running in bypass. Run Permissive in Bypass With run permissive active, the drive sends a run request and waits for a remote response to before notifying the motor to start. The response indicates the system is safe to operate. October

20 VLT High Power Drives (New D Frames) [1] [2] [3] [4] [5] [6] [7] [8] [9] FC NXXX - TX - EXX - H2 - X - G - C - X T4 = VAC 480 V [2] E20 with Graphic LCP [5] RFI Options Brake Option [4] Enclosure Options Chassis Display Option Frame FLA Frame Size FC202 E20 Frame E21 E54 E2M E5M H2 H4 X G L D3h N110 $9,313 nc D1h $975 $1,585 $1,235 $1,845 nc $1,275 nc D5h nc D3h N132 $11,611 nc D1h $975 $1,585 $1,235 $1,845 nc $1,540 nc D5h nc D3h N160 $15,030 nc D1h $1,880 $3,050 $2,355 $3,525 nc $1,885 nc D5h nc D4h N200 $18,121 nc D2h $1,880 $3,050 $2,355 $3,525 nc $2,250 nc D7h nc D4h N250 $20,743 nc D2h $1,880 $3,050 $2,355 $3,525 nc $2,685 nc D5h nc D4h N315 $24,363 nc D2h $3,260 $5,295 $3,955 $5,985 nc $3,250 nc D7h nc $60 T7 = VAC 690 V [2] E20 with Graphic LCP [5] RFI Options Brake Option [4] Enclosure Options Chassis Display Option Frame FLA Frame Size FC202 E20 Frame E21 E54 E2M E5M H2 H4 X G L D3h N75K $7,690 nc D1h $975 $1,585 $1,235 $1,845 nc $1,175 nc D5h nc D3h N90K $8,847 nc D1h $975 $1,535 $1,235 $1,845 nc $1,310 nc D5h nc D3h N110 $9,771 nc D1h $975 $1,585 $1,235 $1,845 nc $1,565 nc D5h nc D3h N132 $11,182 nc D1h $975 $1,585 $1,235 $1,845 nc $1,910 nc D5h nc D3h N160 $12,919 nc D1h $975 $1,585 $1,235 $1,845 nc $2,305 nc D5h nc D4h N200 $15,348 nc D2h $1,880 $3,050 $2,355 $3,525 nc $2,825 nc D7h nc D4h N250 $19,560 nc D2h $1,880 $3,050 $2,355 $3,525 nc $3,375 nc D7h nc D4h N315 $23,067 nc D2h $1,880 $3,050 $2,355 $3,525 nc $4,030 nc D7h nc D4h N400 $27,475 nc D2h $3,260 $5,295 $3,955 $5,985 nc $4,455 nc D7h nc $60 [1] Performance Level 202 AQUA Drive [2] Power Size N75K 75kW (690 Volt Only) N90K 90 kw (690 Volt Only) N HP (110 kw) N HP (132 kw) N HP (160 kw) N HP (200 kw) N HP (250 kw) N kw (315 kw) N kw (690 Volt Only) [3] AC Line Voltage T4 3 phase Vac T7 3 phase Vac [4] Enclosure E20 Protected Chassis IP20 E21 NEMA 1/IP21 E54 NEMA 12/IP54 E2M NEMA 1/ IP21 with Main Shields E5M NEMA 12/IP54 with Main Shields [5] RFI Filter H2 Integral Class A2 RFI Filter H4 Integral Class A1 RFI Filter [6] Brake Options X No Option Installed B Brake IGBT (Brake Resistor sold separately) R Regen Terminals T Safe Stop Terminal U Safe Stop Terminal & Brake IGBT S Regen Terminals & Brake IGBT [7] HMI Option G Graphic LCP Installed L Graphical LCP Installed with USB port on door [8] Conformal Coating C 3C3 Conformal Coated PCB s [9] Mains Input Options X No Option Installed 3 Drive fused Disconnect 4 Mains Contactor & Drive fuses 7 Drive fuses Only A Drive fuses with Loadsharing Terminals D Loadsharing Terminals E Mains Disconnect, Contactor & Drive fuses J Circuit Breaker & Drive fuses [11] Access Panel Options X No Option Installed Q Heat Sink Access Panel [14] Fieldbus Options Adder AX No Option Installed nc A0 Profibus MCA101 Option Card $175 Installed A4 DeviceNet MCA104 Option Card $135 Installed AL ProfiNet MCA120 Option Card $360 Installed AN EtherNet IP MCA121 Option Card $360 Installed AQ Modbus TCP/IP MCA122 Option Card Installed $360 [15] I/O Expansion Option Adder BX No Option Installed nc B0 Analog I/O Batt backup MCB109 $140 Option Card Installed B4 VLT Sensor Input MCB114 Option $140 Card Installed BK General Purpose I/O MCB101 $115 Option Card Installed BP Relay Expansion MCB105 Option $125 card Installed BY Extended Cascade Control MCO101 Option Card Installed $ October 2012

21 VLT High Power Drives (New D Frames) [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] X - X - SXXX - X - AX - BX - CX - X - XX - DX Coating [9] Mains Input Option Access Panel C X 7 A D Frame 3 Frame 4 5 E J X Q T4 = VAC nc nc $315 $690 $375 D5h $2,400 D6h $4,190 $2,770 $5,830 $6,210 nc $330 nc nc $315 $770 $455 D5h $2,400 D6h $4,190 $2,850 $5,830 $6,210 nc $330 nc nc $500 $1,055 $555 D5h $2,400 D6h $4,190 $2,950 $5,830 $6,210 nc $330 nc nc $500 $1,160 $660 D7h $4,125 D8h $6,865 $4,780 $9,605 $10,675 nc $330 nc nc $500 $1,290 $790 D5h $4,125 D8h $6,865 $4,905 $9,605 $10,675 nc $330 nc nc $810 $1,760 $950 D7h $4,125 D8h $6,865 $5,065 $9,605 $10,675 nc $330 Coating [9] Mains Input Option Access Panel C X 7 A D Frame 3 Frame 4 5 E J X Q T7 = VAC nc nc $235 $515 $280 D5h $2,400 D6h $4,190 $2,910 $5,830 $6,210 nc $330 nc nc $315 $690 $375 D5h $2,400 D6h $4,190 $3,080 $5,830 $6,210 nc $330 nc nc $315 $690 $375 D5h $2,400 D6h $4,190 $3,080 $5,830 $6,210 nc $330 nc nc $315 $690 $375 D5h $2,400 D6h $4,190 $3,080 $5,830 $6,210 nc $330 nc nc $315 $770 $455 D5h $2,400 D6h $4,190 $3,160 $5,830 $6,210 nc $330 nc nc $500 $1,055 $555 D7h $4,125 D8h $6,865 $5,170 $9,605 $10,675 nc $330 nc nc $500 $1,160 $660 D7h $4,125 D8h $6,865 $5,275 $9,605 $10,675 nc $330 nc nc $500 $1,290 $790 D7h $4,125 D8h $6,865 $5,405 $9,605 $10,675 nc $330 nc nc $810 $1,760 $950 D7h $4,125 D8h $6,865 $5,485 $9,605 $10,675 nc $330 [17] Motion Control Output Option Adder X None Installed nc 5 Advanced Cascade Control MCO102 Option Installed $1,495 [19] Voltage Input Option Adder DX No Option Installed nc D0 24 V dc Input MCB107 Option Card Installed $75 Accessories Part Number Description List Price 176F3625 kit, cooling, in back out back, D3h $ F3626 kit, cooling, in back out back, D4h $ F3633 kit, cooling, in back out back, 3R, D3h $ F3634 kit, cooling, in back out back, 3R, D4h $ F3627 kit, duct, btm, top, 1800 mm, Rittal, D3h $ F3628 kit, duct, btm, top, 1800 mm, Rittal, D4h $ F3629 kit, duct, btm, top, 2000 mm, Rittal, D3h $ F3630 kit, duct, btm, top, 2000 mm, Rittal, D4h $ F3631 kit, pedestal, 400 mm, D1h $ F3632 kit,pedestal,400mm,d2h $ F3648 kit, cooling, in back out back, D1h $ F3649 kit, cooling, in back out back, D2h $ F3409 kit, adaptor plate, D1h/ D3h $ F3410 kit, adaptor plate, D2h/ D4h $ Power Wiring Lugs are not included in products above 150 HP October 2012 page updated 11/8/

22 VLT High Power Drives E1 E2 E Frame Sizes FC 202 Use the Performance Data Selection charts on pages 5-7 to determine the frame size and enclosure style availability for the selected Power Size [2]. [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] FC X - G X - X - SXXX - X CX - - XX VAC - T VAC - T7 [2] E00 with Graphic LCP [4] Enclosure Options [5] RFI Options Brake Option HP FLA Size Frame Base E00 C00 Frame E21 E54 E2M E5M H2 H4 X P315 E2 $24,363 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc $3, P355 E2 $28,689 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc $3, P400 E2 $34,730 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc $4,355 nc P450 E2 $37,741 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc $4,995 Display Option [8] Coating [9] Mains Input Option HP FLA Size G X C X A D P315 - nc nc $4,150 $5,100 $810 $1,760 $ P355 - nc nc $4,150 $5,270 $810 $1,930 $1,120 nc P400 - nc nc $4,150 $5,420 $810 $2,080 $1, P450 - nc nc $4,150 $5,660 $810 $2,320 $1,510 [2] E00 with Graphic LCP Enclosure Options RFI Options Brake Option kw FLA Size Frame Base E00 C00 Frame E21 E54 E2M E5M H2 H4 X P450 E2 $33,576 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc P500 E2 $43,013 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc P560 E2 $53,459 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc - nc P630 E2 $62,253 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc - Display Option Coating Mains Input Option kw FLA Size G X C X A D P450 - nc nc $4,150 $5,100 $810 $1,760 $ P500 - nc nc $4,150 $5,270 $810 $1,930 $1,120 nc P560 - nc nc $4,150 $5,420 $810 $2,080 $1, P630 - nc nc $4,150 $5,660 $810 $2,320 $1,510 [1] Performance Level 322 AQUA Drive [2] Power Size P HP (315 kw T4 Voltage Only) P HP (355 kw T4 Voltage Only) P HP (400 kw T4 Voltage Only) P HP (450 kw) P kw (T7 Voltage Only) P kw (T7 Voltage Only) P kw (T7 Voltage Only) [3] AC Line Voltage T2 3Ø VAC T4 3Ø VAC [4] Enclosure E00 Chassis IP00 C00 Chassis IP00 with Stainless Steel Back Channel E2M NEMA 1/IP21 with Mains Shield E5M NEMA 12/IP54 with Mains Shield E21 NEMA 1/IP21 E54 NEMA 12/IP54 [6] Braking X No brake IGBT B Brake IGBT mounted (resistor sold separately T Safe stop terminal U Safe stop with brake R Regen Terminals [8] Conformal Coating FC202 PCB s are always coated - the degree of protection is as described below C Upgraded 3C3 Conformal Coating [5] RFI Filter H2 Integral class A2 RFI filter H4 Integral class A1 and B1 RFI filter Power Wiring Lugs are not included in products above 150 HP For Common Options see page 3. [9] Mains Input X No option 3 Mains disconnect and drive fuses 5 Mains disconnect, drive fuses and loadsharing 7 Drive fuses A Drive fuses and loadsharing D Loadsharing terminals 22 October 2012

23 VLT High Power Drives F1 F2 F3 F4 F Frame Sizes FC 202 Use the Performance Data Selection charts on pages 5-7 to determine the frame size and enclosure style availability for the selected Power Size [2]. Contact Factory for complete pricing and ordering instructions [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] FC X - G X - X - SXXX - X CX - - XX - [1] Performance Level 202 AQUA Drive [2] Power Size P HP (480 VAC Only) P HP (480 VAC Only) P HP (480 VAC Only) P HP/630 kw P HP/710 kw P HP/800 kw P kw (690 VAC Only) P1M2 P1M kw (690 VAC Only) 1400 KW (690 V only) [3] AC Line Voltage T4 3Ø VAC T7 3Ø VAC [4] Enclosure E21 IP21 NEMA 1 IP21 NEMA 1 with cabinet light and L2X IEC 230 VAC power outlet IP21 NEMA 1 with cabinet light and L2A IEC 115 VAC power outlet H21 IP21 NEMA 1 with space heater and thermostat R2X IP21 NEMA 1 with space heater, thermostat, cabinet light and IEC 230 VAC power outlet R2A IP21 NEMA 1 with space heater, thermostat, cabinet light and IEC 115 VAC power outlet E54 IP54 NEMA 12 LEX IP54 NEMA 12 with cabinet light and IEC 230 VAC power L5A IP54 NEMA 12 with cabinet light and IEC 115 VAC power H54 IP54 NEMA 12 with space heater and thermostat R5X IP54 NEMA 12 with space heater, thermostat, cabinet light and IEC 230 VAC power outlet R5A IP54 NEMA 12 with space heater, thermostat, cabinet light and IEC 115 VAC power outlet E5H IP54 NEMA 12 hybrid for low harmonic drive (must specify L2 or L4 for RFI option) [5] RFI filter H2 Integral Class A2 filter H4 Integral Class A1 & B1 filter HE Integral Class A2 filter with residual current monitor HF Integral Class A1 & B1 filter with residual current monitor HG Integral Class A2 filter with insulation resistance monitor HH Integral Class A1 & B1 filter with insulation resistance monitor HJ Integral Class A2 filter with NAMUR terminals HK Integral Class A1 & B1 filter with NAMUR terminals HL Integral Class A2 filter with residual current monitor & NAMUR terminals HM Integral Class A1 & B1 filter with residual current monitor & NAMUR terminals HN Integral Class A2 filter with insulation resistance monitor & NAMUR terminals HP Integral Class A1 & B1 filter with insulation resistance monitor & NAMUR terminals N2* Low Harmonic Filter with integral A2 filter (specify E21 or E5H for enclosure option) Power Wiring Lugs are not included in products above 150 HP October

24 VLT High Power Drives Contact Factory for complete pricing and ordering instructions [6] Braking X None B Brake IGBT only (resistor sold separately) M IEC emergency stop pushbutton with Pilz safety relay N Brake IGBT with IEC emergency stop pushbutton with Pilz safety relay P IEC emergency stop pushbutton with regeneration terminals R Regeneration terminals only [8] Conformal Coating FC202 PCB s are always coated - the degree of protection is as described below X Standard 3C2 Conformal Coating C Upgraded 3C3 Conformal Coating [9] Mains Input X None E Mains disconnect switch, contactor and drive fuses F Mains circuit breaker, contactor and drive fuses G Mains disconnect switch, contactor, loadsharing terminals and drive fuses H Mains circuit breaker, contactor, loadsharing terminals and drive fuses J Mains circuit breaker and drive fuses K Mains circuit breaker, loadsharing terminals and drive fuses [10] Power Terminals and Motor Starters X None E 30 Amp fuse protected power terminal F 30 Amp fuse protected power terminal & Amp manual motor starter G 30 Amp fuse protected power terminal & Amp manual motor starter H 30 Amp fuse protected power terminal & Amp manual motor starter J 30 Amp fuse protected power terminal & Amp manual motor starter K Two Amp manual motor starters L Two Amp manual motor starters M Two Amp manual moor starters N Two Amp manual motor starters [11] Auxiliary 24 V Supply & External Temperature Monitoring X None H 5 Amp 24 V power supply G 5 Amp 24 V power supply & External Temperature Monitoring J External Temperature Monitoring [12] Language Package X Standard Package [13] LCP Language Pack Price X Standard language pack nc [14] Fieldbus Price AX No Fieldbus Option Installed nc A0 Profibus MCA101 Option Card $175 A4 DeviceNet MCA104 Option Card $135 AL Profinet MCA120 Option Card $360 AN Ethernet IP MCA121 Option $360 Card AQ Modbus TCP/IP MCA122 Option Card $360 [15] Application Option Price BX No application option nc B0 Analog I/O + RTC Battery $225 Backup MCB 109 B4 VLT Sensor Input MCB114 $140 Option Card BK General Purpose I/O MCB101 $115 Option Card BP Relay Expansion MCB105 $125 Option Card BY Extended Cascade Control with MCO 101 Option Card $995 [17] Motion Control Output Price X No motion control output nc option 5 Advanced Cascade Control with MCO102 Option Card $1,495 [19] Voltage Input Price DX No DC Input Option Installed nc D0 24 Vdc MCB107 Option Card $75 24 October 2012

25 VLT AQUA Low Harmonic Drive Custom Drives Configured Drives New Danfoss low harmonic drives continuously regulate the network and load conditions without affecting the connected motor. Low harmonic drives are available for the D, E and F frame size drives covering the power range. The low harmonic drives are offered in a NEMA 1/ IP21, or NEMA 12/IP54 rated enclosure. Low harmonic drives are available for VAC (T4) input only. Two low harmonic versions are available: N2 With integral A2 Filter N4 With Integral A1 & B1 Filter How to Order: When specifying a D, E or F Frame Size drive, use N2 or N4 (see table below) for item [5] in the typecode. Note: for the D Frame Size, G (Graphic LCP installed) for item [7] and C (conformal coating on all PCBs) for item [8] must be selected. Refer to page 3 for complete typecode information. [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] FC X - G X - X - SXXX - X CX - - XX - T4 Frame HP FLA w Graphic LCP Enclosure Options LHD Option [8] Coating Mains Input Option Size Base E21 E54 N2 N4 X C X P160 $15,030 $ 1,880 $ 4,895 $ 20,070 $ 22,838 nc $425 nc $1,645 $ 500 D P200 $18,121 $ 1,880 $ 4,895 $ 21,260 $ 25,410 nc $425 nc $1,645 $ P250 $20,743 $ 1,880 $ 4,895 $ 23,725 $ 29,095 nc $425 nc $1,645 $ P315 $24,363 $ 3,260 $ 9,360 $ 27,815 $ 34,310 - nc nc $4,150 $ 810 E P355 $28,689 $ 3,260 $ 9,360 $ 30,395 $ 38,060 - nc nc $4,150 $ P400 $34,730 $ 3,260 $ 9,360 $ 31,580 $ 40,285 - nc nc $4,150 $ P450 $37,741 $ 3,260 $ 9,360 $ 36,720 $ 46,710 - nc nc $4,150 $ 810 [2] Power Size P HP/160 kw P HP/200 kw P HP/250 kw P HP/315 kw P HP/355 kw P HP/400 kw P HP/450 kw [3] AC Line Voltage T4 3 Ø VAC [4] Enclosure Type E21 NEMA 1/ IP21 E54 NEMA 12/IP54 [5] RFI Filter N2 Low harmonic filter with integral A2 filter. N4 Low harmonic filter with integral A1 & B1 filter. [6] Brake/Safe Stop Options X None B Brake igbt installed (resistor sold separately) R Regen terminals (e frame drives only) T Safe stop terminal (FC202 Only) U Brake igbt with safe stop terminal (FC202 only) [7] HMI Option G Graphical LCP included on all models [8] Conformal Coating FC202 PCB s are always coated - the degree of protection is as described below X Standard 3C2 Conformal Coating C Upgraded 3C3 Conformal Coating [9] Mains Input Options X No option installed 3 Mains disconnect switch & drive fuses 5 Mains disconnect switch, drive fuse and loadshare terminals 7 Drive fuses only A Drive fuses with loadshare terminals D Loadshare terminals only Power Wiring Lugs are not included in products above 150 HP For Common Options see page 3. October

26 VLT AQUA Drive Options and Accessories Fieldbus options/accessories (A-Card) The VLT AQUA Drive is available with a variety of fieldbus products which are available as factory-installed options or as field-installed accessories. VLT Modbus RTU Modbus RTU is a standard Protocol built-in to every FC 202 AQUA drive. Modbus is a serial communications protocol that follows the Modbus Organization standards. It is used to connect a supervisory control and data acquisition (SCADA) system with a remote terminal unit (RTU) VLT MCA 101 Profibus Supported by all major PLC vendors, PROFIBUS DP V1 gives you a high level of availability and compatibility with future versions. Fast and efficient communication, advanced diagnosis and autoconfiguration of process data via GSD files Acyclic parameterization using PROFIBUS DP V1, PROFIdrive or Danfoss FC profi e state machines, PROFIBUS DP V1, Master Class 1 and 2 VLT MCA 104 DeviceNet Based on Producer/Consumer technology, DeviceNet offers robust, efficient data handling. Allows the user to select the nature and timing of reported information Certified by ODVA to meet the stringent ODVA standard ADR (Auto Device Recovery) Compatible VLT Profinet RT MCA 120 The VLT PROFINET Option offers connectivity to PROFINET based networks via the PROFINET Protocol. The option is able to handle a single connection with an Actual Packet Interval down to 1 ms in both directions, positioning it among the fastest performing PROFINET devices in the market. Built-in web server for remote diagnosis and reading out of basic drive parameters An notificator can be configured for sending an message to one or several receivers, if certain warnings or alarms occur, or have cleared again TCP/IP for easy access to Drive configuration data from VLT MCT 10 FTP (File Transfer Protocol) file up and download Support of DCP (discovery and configuration protocol) VLT MCA 121 EtherNet IP Provides the network tools to deploy standard Ethernet technology for manufacturing applications while enabling Internet and enterprise connectivity. Built-in advanced switch with diagnostic functions and two ports for line topology Built-in web server and client for service notification Transparent socket channel Certified by ODVA to meet the stringent ODVA standard Option Order Code* Conformal Coated to 3C2 Accessory Part Number Conformal Coated to 3C3 List Price MCA 101 Profibus A0 130B B MCA 104 DeviceNet A4 130B B MCA 120 Profinet RT AL 130B B MCA 121 Ethernet AN 130B B MVA 122 Modbus TCP/IP AQ 130B B * Factory installed at time of drive purchase. See order configuration code on page 3. Inserted into position [14] of the string code. 26 O/A PL page updated 10/26/2012 October 2012

27 VLT AQUA Drive Options and Accessories VLT MCB 105 Relay Extend the relay functions of the VLT AQUA Drive with 3 extra relay outputs. Max. terminal load: AC-1 Resistive load 240V AC: 2A AC-15 cos φ 0.4: 0.2A DC-1 Resistive load 240V AC: 1A DC-13 cos φ 0.4: 0.1A Min. terminal load: DC 5 V: 10 ma Max. switch rate at rated load/min. load: 6 min -1 /20 sec -1 Protected control cable connection Spring-loaded connection of control wires Selection of relay functions in parameter settings Application Options/Accessories (B-Card) The VLT AQUA Drive is available with several added-functionality application products which are available as factoryinstalled options or as field-installed accessories. VLT MCB 101 General Purpose I/O Offers an extended number of control inputs and outputs: 3 digital inputs 0 24 V: Logic 0 < 5 V; Logic 1 >10V 2 analog inputs 0 10 V: Resolution 10 bit plus sign 2 digital outputs NPN/PNP push pull 1 analog output 0/4 20 ma Spring-loaded connection Separate parameter settings VLT MCB 109 Analog I/O Provides battery back-up of clock function on control card Extension of analog I/O selection Support Extended PID controllers VLT MCB 114 sensor inputs 1 Analog Input 0/4-20mA Input Impedance <200Ω Sample rate 1kHz 3 PT100/ or 3 wire Option Order Code* Conformal Coated to 3C2 Accessory Part Number Conformal Coated to 3C3 List Price MCB 114 PTC Sensor input card B4 130B B MCB 101 I/O BK 130B B MCB 105 Relay BP 130B B MCB 109 Analog I/O B0 130B B * Factory installed at time of drive purchase. See order configuration code on page 3. Insert into position [15] of the string code. MCB 101 MCB 105 MCB 109 MCB 114 I/O FC 200 GP I/O Relay Analog I/O Sensor Input Digital Input 6* +3 Digital Output 2* +2 Analog Input (0-10V) +1 Analog Output (0-10V) Relay-form c 2 +3 Real Time Clock Battery Back-up 1 PT100/PT * 2 Digital inputs can be configured as Digital Outputs. October 2012 O/A PL 27

28 VLT AQUA Drive Options and Accessories VLT MCO 101 Extended Cascade Controller (B-Card) Extends the capabilities of the standard Cascade Controller built into VLT Series drives: Provides 3 additional relays for staging of additional motors Provides accurate flow, pressure, and level control for optimizing the efficiency of systems that use multiple pumps or blowers Master/Follower mode runs all blowers/pumps at the same speed, potentially reducing the energy consumption to less than half that of valve throttling or traditional, across-the-line on/off cycling Lead pump alternation assures that pumps or blowers are used equally VLT MCO 102 Advanced Cascade Controller (C-Card) MCO 102 Advanced Cascade Controller The Advanced Cascade Controller option provides the capability to control multiple pumps configured in parallel in a way that makes them appear as a single larger pump. Using the Advanced Cascade Controller individual pumps are automatically turned on (staged) and turned off (destaged) as needed to satisfy the required system output for flow or pressure. The speed of the pumps connected to the VLT AQUA Drives is also controlled to provide a continuous range of system output. The Advanced Cascade Controller option card controls up to five parallel pumps. The controller provides constant pressure or level control in such systems, and reduces water hammer and energy consumption. The controller also eliminates the need for PLCs and external controllers. The Advanced Cascade Controller is available as a factory-installed option or as field-installed accessory, and is designed for a variety of applications including: Pressure booster pump systems Tank level control Pressure control Lift station pump control Irrigation pump systems Wastewater blower systems Function Option Order Code* This illustration depicts a typical VLT AQUA Drive installation utilizing the Cascade Controller option. The controller is being used in conjunction with MCD Series Soft Starters to operate one to four pumps as demand requires. VLT AQUA Standard Accessory Part Number Conformal Coated to 3C2 EXTENDED MCO 101 Option B Conformal Coated to 3C3 ADVANCED MCO 102 Option C VLT AQUA Relays Maximum number of pumps to control Variable Speed Constant speed (softstarter or across the line) BASIC functionality X X X Master-Follower X X Maximize system efficiency X X Stage/De-Stage operation Automatic Tuning for best efficiency Automatic for minimum surge/sag Runtime priority X X Alternating lead pump with one relay per pump (only old and new lead pump to stop) X (2) X (4) Alternating lead pump at staging X (4) Control of unequal sized pumps X X Operation hours counter for relays X Operation hours counter for both relays and pumps X X If you use the Extended Controller, which fits in the B option slot, you cannot add additional I/O to the VLT AQUA If you use the Advanced Controller, which fits in the C option slot, you can add additional I/O to the VLT AQUA List Price MCO 101 Extended Cascade Controller BY 130B B1218 $1, MCO 102 Advanced Cascade Controller C5** 130B B1254 $1, * Factory installed at time of drive purchase. See order configuration code on page 3. Insert into position [17] of string code ** See option field mounting kits. X X X X 28 O/A PL October 2012

29 VLT AQUA Drive Options and Accessories D Option Card Part # Product Type Description List Price 130B1108 MCB 107 Uncoated 24V supply input option $ B1208 MCB 107 Coated 24V supply input option $ D Option Card Local Control Panels & Accessories Part # Product Type Description List Price 130B1124 LCP101 LCP 101 Numerical Local Control Panel $ B1107 LCP102 LCP 102 Graphical Local Control Panel $ B1113 MCF102 LCP Panel Mounting Kit, incl. graph. LCP $ B1114 MCF102 LCP Panel Mounting Kit, incl. numeric LCP $ B1117 MCF102 LCP Panel Mounting Kit, All LCPs $ Z0929 Option, Remote LCP cable,3m $ B1155 MCF103 USB extension, 350 mm cable $ B1156 MCF103 USB extension, 650 mm cable $55.00 HMI (faceplate) options from left to right: Graphic 130B1124 Numeric 130B1107 Blank (must be configured with drive) Accessories Part # Description List Price 130B1116 Screw terminals/screw terminal kit $ B1064 Terminal Block for DC Link connection on A2/A3 Frames $ B1021 Accessory Bag for A1 Frame $ B1022 Accessory Bag for A5 Frame $ B1023 Accessory Bag for A2/A3 Frame $ B0633 Accessory Bag for A1-A5 Frame (brake & load share connector) $ B2060 Accessory Bag for B1 Frame $ B2061 Accessory Bag for B2 Frame $ B0980 Accessory Bag for B3 Frame $ B1300 Accessory Bag for B4 Frame ( kw) $ B1301 Accessory Bag for B4 Frame (30 kw) $ B0046 Accessory Bag for C1 Frame $ B0047 Accessory Bag for C2 Frame $ B0981 Accessory Bag for C3 Frame $ B0982 Accessory Bag for C4 Frame (55 kw) $ B0983 Accessory Bag for C4 Frame (75 kw) $45.00 Remote mounting kit 130B1117 C Option Field Mounting Kits Part # Description List Price 130B7530 C Option Mounting Kit for A2 & A3 (40 mm) $ B7531 C Option Mounting Kit for A2 & A3 (60 mm) $ B7532 C Option Mounting Kit for A5 $ B7533 C Option Mounting Kit for B, C, D, E, F $ B1413 C Option Mounting Kit for B3 (40 mm) $ B1414 C Option Mounting Kit for B3 (60 mm) $ pole, spring-loaded connector 130B1071 October 2012 page updated 11/8/2012 O/A PL 29

30 VLT AQUA Drive Options and Accessories High Power Option Kits Part # DescrIPtion List Price 176F4600 kit,nema 3R,rittal,D3 $1, F4601 kit,nema 3R,rittal,D4 $1, F1852 kit,nema 3R,rittal,E2 $4, F0296 kit,nema 3R,industrial enclosure,d3 $1, F0295 kit,nema 3R,industrial enclosure,d4 $ F0298 kit,nema 3R,industrial enclosure,e2 $2, F1827 kit, pedestal, D1 D2 $1, F1824 kit,cooling duct,1800 mm rittal,d3 $ F1823 kit,cooling duct,1800 mm rittal,d4 $ F1826 kit,cooling duct,2000 mm rittal,d3 $ F1825 kit,cooling duct,2000 mm rittal,d4 $ F1850 kit,cooling duct,2000 mm rittal,e2 $1, F0299 kit,cooling duct,2200 mm rittal,e2 $2, F1775 kit, duct, top only, D3/D4 $ F1776 kit, duct, top only, E2 $ F1862 kit,top and bottom covers,d3,d4 $ F1861 kit, top and bottom covers, E2 $ F1946 IP21/54 top and bottom covers, E1 $ F1945 IP21/54 top/bottom covers, D1/D2 $ Steel Backplates Part # Type Description List Price 130B3150 MCF108 Backplate A B1098 MCF108 Backplate A B3383 MCF108 Backplate B B3397 MCF108 Backplate B B4172 MCF108 Backplate B B3910 MCF108 Back plate C B3911 MCF108 Back plate C B4170 MCF108 Back plate C B4171 MCF108 Back plate C F1781 top & bottom covers for rittal enclosure, D3 $ F1782 top & bottom covers for rittal enclosure, D4 $1, F1783 top & bottom covers for rittal enclosure, E2 $2, F1774 kit,motor cable clamp brkt,ip00,d3 $ F1746 kit,motor cable clamp brkt,ip00,d4 $ F1745 kit,motor cable clamp brkt,ip00,e2 $ F1779 kit, IP20 conversion, D3/D4 $ F1884 IP20 conversion kit, E2 $ F0799 kit,mains shield,d1 D2 $ F1851 kit,mains shield,e1 $ F8456 kit,loadshare,d1 D3 $ F8455 kit,loadshare,d2 D4 $ F1843 kit,loadshare,e-frame, T4/T5 $ F1844 kit,loadshare,e-frame, T7 $ F1742 kit,fc profibus sub-d9, D and E $ Stainless Steel Backplates (Type 304) Part # Type Description List Price 130B3158 MCF108 Backplate A4, NEMA 4X/IP B3242 MCF108 Backplate, A5, NEMA 4X/IP B3434 MCF108 Backplate/ B1, NEMA 4X/IP B3465 MCF108 Backplate B2, NEMA 4X/IP B3468 MCF108 Backplate C1, NEMA 4X/ IP B3491 MCF108 Backplate C2, NEMA 4X/ IP Weather Shield Part # Description List Price 130B4598 A4 B2 Frames B4597 C1 C2 Frames B O/A PL October 2012

31 VLT AQUA Drive Options and Accessories Through Panel Mounting Kits Fits Frame Height Width Depth Part Number List Price A B1028 $90.00 B B1046 $ B B1047 $ C B1048 $ C B1049 $ Allows the drive to be mounted through the back of a panel wall so that cooling air can remove the heat without the risk of damaging electronics with dust, heat, moisture, or corrosive elements. For use with IP21 and IP55 units with the front cover removed. The drive can be mounted with the heatsink exposed in a duct with a cooling airstream provided by external fans either dedicated for the purpose or as part of a process close to the drive. If this configuration is used, the drive s built-in fan can be removed. If the drive is not mounting into a duct with an existing airflow, adding a backplate (purchased separately) creates a duct through which the drive s built-in fan can force cooling air over the heatsink. NEMA 1 Option Kits for IP20 A, B and C Frames Fits Frame HP Range (High Overload) 230V 460V 600V Height Width Depth Part Number List Price A2 1/3 to 3 1/2 to B B1132* A3 4 to 5 7-1/2 to 10 1 to B B1133* B B B B C B C B * Top Only subtract 3.1 from height. B and C Frames October 2012 page updated 10/31/2012 O/A PL 31

32 DrivePro Professional Drive Support Danfoss DrivePro TM offers a comprehensive selection of startup and servicing programs that ensure your drive installation s performance from date of shipment through the life of the application. Prices and Multipliers The DrivePro products and services described on the following pages are all at list price. Multipliers apply as follows: Extended Warranty or Startup & Training Services ordered with a drive will use the same multiplier as the drive Startup & Training Services ordered on demand (separately from the drive order) will use the standard VLT AQUA Drive multiplier, as applicable Repair and field support orders use the standard DrivePro multiplier Additional Service Options Please call Danfoss for a quote on any service options not listed in this book, including but not limited to: Post-warranty service contracts Preventive maintenance contracts Equipment migration contracts Extended service warranty contracts for nondrive products Repairs of other products Spare drives on-site service contracts Drive lease-to-own programs Micro & VLT 2800 VLT AQUA Drive Products covered MCD 200 MCD 500 AAF AHF LHD, AFE, 12 Pulse DrivePro Applications & Field Service Assistance 33 DrivePro Exchange Warranty year coverage DrivePro Startup Service 34 Optional Onsite Training Factory Depot Repairs 35 DrivePro Startup Service with DrivePro-tection Onsite Drive Coverage Contract year coverage DrivePro-tection Onsite Drive Coverage Contract year coverage DrivePro Startup with Enhanced Onsite Service Warranty year coverage Enhanced Onsite Service Warranty year coverage Page 32 DPRO PL October 2012

33 DrivePro Professional Drive Support DrivePro Applications & Field Assistance DrivePro product multiplier applies to repair services Emergency Shipping Services A $300 handling fee will be added for emergency shipments performed outside of normal working hours (8:00 am to 5:00 pm or weekends). Additional charges will apply to cover shipping and delivery cost. Field Service Rates Product Applications Support Hourly rates* Product Service and Training Support Monday Friday 8:00 am to 5:00 pm $180 $120 Monday Friday Before 8:00 am and after 5 pm Saturday 8:00 am to 5:00 pm Saturday Before 8:00 am or after 5:00 pm Sunday and US Holidays * Field Service pricing applies to locations in the U.S. or Canada. The minimum available field support is 4 hours of billable support in addition to travel and expense charges. Travel time is billed at 1/2 the applicable field service rate. Travel expenses (air fare, hotel, auto rental, fuel, parking tolls, etc.) are billed at cost. DrivePro Exchange Warranty Drive order multiplier applies when purchased with drive Available for: VLT MICRO VLT 2800 MCD 100 & 200 Soft Starters Exchange Warranty extends the product warranty beyond the standard period. Coverage begins on the date of shipment and extends to the end of the contract period. Micro < 7.5 Hp VLT 2800 < 1.5 kw MCD 100 & 200 < 55kW Micro Hp VLT kw MCD 100 & 200 > 55kW MCD 200 ( kw)vlt 2800 > 7.5 kw Total coverage from end of std warranty Tier 2 year 3 year 4 year 5 year EX124 EX136 EX148 EX160 Ordering number 1 $90 $120 $150 $180 List price per drive 2 3 EX224 EX236 EX248 EX260 Ordering number $140 $190 $250 $300 List price per drive EX324 EX336 EX348 EX360 Ordering number $240 $350 $460 $570 List price per drive October 2012 DPRO PL 33

34 DrivePro Professional Drive Support DrivePro Startup Service Drive order multiplier applies when purchased with drive Standard Drive multiplier applies for on-demand purchases This chart applies to All Danfoss Drive Products Purchase type Pre Pay* On Demand** Pre Pay* or On Demand** Power range 1/2 Day 1/2 Day Full Day Max hours onsite All VAC Frame 1**** 1**** 1**** Max trips included All power sizes All SUPW01 SUDW01 SUFW01 Ordering number $830 $890 $1,400 List price per service during standard business hours*** *Pre Pay = purchased with drive - invoiced at the time of drive shipment **On demand = purchased after drive shipment from factory - invoiced at the time of service *** Standard business hours = 8:00 AM - 5:00 PM Monday - Friday excluding holidays **** Maximum 2 hour round-trip Additional services Product training by a DrivePro certified technician at time of start-up service during standard business hours***. Training includes basic product operating instructions and application specific drive programming. Additional trips (when service purchased is split over multiple days) List Price $120 / hour $120 / hour Non Standard business hours Start-up or Training Service Monday - Friday before 8:00 AM or after 5:00 PM or Saturdays 8:00 AM - 5:00 PM LP x 1.5 Sundays, Holidays and Saturdays before 8:00 AM or after 5:00 PM LP x 2 Service Terms Start-up service is performed by a Danfoss Authorized Service Partner organization. DrivePro certified technician inspects drive & installation, programs the Danfoss product as needed for application and tests drive functions as allowed by customer & system readiness. Danfoss reserves the right to bill at standard Danfoss onsite labor rates for time over the maximum and additional trips. Pricing applies to drives installed in the 48 adjacent states; Oahu, Hawaii; Anchorage, Alaska; and major metropolitan areas of Canada. Travel to other areas within the U.S. or Canada is available at the additional trip hourly rate plus overnight expenses. Startup Stipulation Start-up service does not include product installation, wiring, technical support of system integrations such as PLC programming or serial communications system verification. Wire terminations are to be completed but no power is to be applied to the drive prior to Danfoss Start-up service. Application of power prior to Start-up service may result in damage to the drive product. Repair of this type of damage is not included in the product warranty or startup service. Pricing applies to drives installed in the 48 adjacent states; Oahu, Hawaii; Anchorage, Alaska; and Canada. Danfoss will charge for Start-up and/or service travel time over 1 hour each way; refer to the Field Service Rate price table on page 33 for pricing. 34 DPRO PL October 2012

35 DrivePro Professional Drive Support Factory Depot Repairs Flat Rate Repair Pricing Drive repairs and other services performed by Danfoss technicians at the Danfoss Drives North America facility. Service multiplier applies. Ordering number List price Variable torque models Constant torque models VLT 4000, VLT 6000, VLT 8000 VLT HVAC Drive, VLT AQUA VLT 5000, VLT 5000 FLUX VLT AutomationDrive V V V V V V V V V V V V FFR-1 $320 X002 X002 X X003 X FFR-2 $370 X003 X004 X X004 X X005 X006 X FFR-3 $470 X006 X008 X X008 P5K FFR-4 $650 X011 X011 X011 P7K P5K5 X016 X016 P11K P11K FFR-5 $850 X016 X022 X022 P11K P15K P15K P7K5 P11K P11K X022 P15K 5016 P11K FFR-6 $1,070 X027 X027 X027 P18K P18K P18K P15K P15K P15K X032 P22K 5027 P18K FFR-7 $1,170 X032 X032 P22K P22K P18K P18K X042 X042 P30K P30K P22K P22K FFR-8 $1,280 X042 X052 X052 P30K P37K P37K P22K P30K P30K FFR-9 $1,530 X052 X062 X062 P37K P45K P45K P30K P37K P37K FFR-10 $1,630 X072 X072 P55K P55K P45K P45K FFR-11 $1,820 X062 X102 X102 P45K P75K P75K P37K P55K P55K FFR-12 $1,940 X122 X122 P90K P90K P75K P75K FFR-13 $2, P90K P90K Factory Inspection Fees PART NO. LIST PRICE DRIVES COVERED INSP-1 $85 FCM/FCD INSP-2 $85 VLT MICRO INSP-3 $85 VLT 2800 INSP-4 $165 All series 1-10 HP INSP-5 $235 All series HP INSP-6 $350 All series HP INSP-7 $175 All Soft Staters & AHF Depot Service Expedite Fees Same day turnaround* $ hour turnaround* $ hour turnaround* $ hour turnaround* $110 Turnaround times are based on normal 8:00 am to 5:00 pm Monday through Friday work days and apply from the time the product is received until the time it is shipped from the repair facility. For same day turnaround, products must be received at the repair facility by 9:00 am. Service Depot Repair Rates Monday - Friday 8:00 AM - 5:00 PM Monday - Friday before 8:00 AM or after 5:00 PM Saturday 8:00 AM - 5:00 PM Saturday before 8:00 AM or after 5:00 PM Sunday or US Holiday $100 / hr $130 / hr $130 / hr $170 / hr $170 / hr *Expedited turnaround is available during normal M - F workdays. Turnaround time does not include product transit time. Products must be received by 9:00 AM to qualify for same day turnaround Flat Rate price repairs excludes shipping Repairs for drives not listed: FC series A Frame, MICRO Drive, VLT 2800 Drive, FCM & FCD Drive repairs are not available FC series D, E & F frame, and MCD 500 repaired at hourly Service Depot Repair rates October 2012 DPRO PL 35

36 DrivePro Professional Drive Support DrivePro Startup Service with DrivePro-tection Onsite Drive Coverage Contract Drive order multiplier applies when purchased with drive Use this table for VLT AQUA & VLT Automation Drive, MCD 500 Soft Starter, Advance Harmonic Filter (AHF), Advanced Active Filter (AAF), Standard panel options (bypass, motor selection & line or load filters) HP Range (VT) Total coverage from date of shipment 208 VAC 460 / 600 VAC Frame 1.5 year 2 year 3 year 4 year 5 year 6 year A Ordering number DTSW118 DTSW124 DTSW136 DTSW148 DTSW160 DTSW172 List price per drive $930 $970 $1,060 $1,140 $1,210 $1, B Ordering number DTSW218 DTSW224 DTSW236 DTSW248 DTSW260 DTSW272 List price per drive $1,020 $1,100 $1,240 $1,380 $1,530 $1, C Ordering number DTSW318 DTSW324 DTSW336 DTSW348 DTSW360 DTSW372 List price per drive $1,230 $1,370 $1,660 $1,940 $2,220 $2, D Ordering number DTSW418 DTSW424 DTSW424 DTSW448 DTSW460 DTSW472 List price per drive $1,570 $1,830 $2,350 $2,860 $3,390 $3, E Ordering number DTSW518 DTSW524 DTSW536 DTSW548 DTSW560 DTSW572 List price per drive $2,830 $3,480 $4,800 $6,120 $7,420 $8,720 Use this table for Engineered Drives Systems (EDS - drives & panel packages), Low Harmonic Drive (LHD), Active Front End Drive (AFE), 12 Pulse Drive HP Range (VT) Total coverage from date of shipment 208 VAC 460 / 600 VAC Frame 1.5 year 2 year 3 year 4 year 5 year 6 year A Ordering number DTPSW118 DTPSW124 DTPSW136 DTPSW148 DTPSW160 DTPSW172 List price per drive $980 $1,020 $1,130 $1,220 $1,320 $1, B Ordering number DTPSW218 DTPSW224 DTPSW236 DTPSW248 DTPSW260 DTPSW272 List price per drive $1,090 $1,180 $1,350 $1,530 $1,700 $1, C Ordering number DTPSW318 DTPSW324 DTPSW336 DTPSW348 DTPSW360 DTPSW372 List price per drive $1,340 $1,510 $1,870 $2,220 $2,560 $2, D Ordering number DTPSW418 DTPSW424 DTPSW436 DTPSW448 DTPSW460 DTPSW472 List price per drive $1,760 $2,080 $2,720 $3,350 $4,000 $4, E Ordering number DTPSW518 DTPSW524 DTPSW536 DTPSW548 DTPSW560 DTPSW572 List price per drive $3,300 $4,110 $5,740 $7,360 $8,960 $10,560 Coverage Terms: DrivePro-tection w/ Start-up combines SU service for one drive with a product warranty upgrade by covering travel cost (maximum 2 hours round trip) to the customer site and coverage of accidental damage to the product after installation, including the following: Momentary line or load anomalies such as lightning strikes. Accidental collision after installation Temporary exposure to moisture or corrosives Danfoss excludes coverage for failures due to product vandalism, miss-application, shipping or installation damage, chronic destructive site conditions or site catastrophes such as floods, fires, hurricanes or tornados. Pricing applies to drives installed in the 48 adjacent states; Oahu, Hawaii; Anchorage, Alaska; and Canada. Danfoss will charge for Startup and/or service travel time over 1 hour each way; refer to the Field Service Rate price table on page 33 for pricing. 36 DPRO PL page updated 11/6/2012 October 2012

37 DrivePro Professional Drive Support DrivePro-tection Onsite Drive Coverage Contract Drive order multiplier applies when purchased with drive Use this table for VLT AQUA & VLT Automation Drive, MCD 500 Soft Starter, Advance Harmonic Filter (AHF), Advanced Active Filter (AAF), Standard panel options (bypass, motor selection & line or load filters) HP Range (VT) Total coverage from date of shipment 208 VAC 460 / 600 VAC Frame 1.5 year 2 year 3 year 4 year 5 year 6 year A Ordering number DTW118 DTW124 DTW136 DTW148 DTW160 DTW172 List price per drive $190 $230 $310 $390 $470 $ B Ordering number DTW218 DTW224 DTW236 DTW248 DTW260 DTW272 List price per drive $280 $350 $490 $640 $780 $ C Ordering number DTW318 DTW324 DTW336 DTW348 DTW360 DTW372 List price per drive $480 $620 $910 $1,190 $1,470 $1, D Ordering number DTW418 DTW424 DTW436 DTW448 DTW460 DTW472 List price per drive $820 $1,080 $1,600 $2,120 $2640 $3, E Ordering number DTW518 DTW524 DTW536 DTW548 DTW560 DTW572 List price per drive $2,080 $2,730 $4,050 $5,370 $6,670 $7, F Ordering number DTW618 DTW624 DTW636 DTW648 DTW660 DTW672 List price per drive $4,000 $5,240 $7,740 $10,270 $12,710 $15,250 Use this table for Engineered Drives Systems (EDS - drives & panel packages), Low Harmonic Drive (LHD), Active Front End Drive (AFE), 12 Pulse Drive HP Range (VT) Total coverage from date of shipment 208 VAC 460 / 600 VAC Frame 1.5 year 2 year 3 year 4 year 5 year 6 year A Ordering number DTPW118 DTPW124 DTPW136 DTPW148 DTPW160 DTPW172 List price per drive $230 $280 $380 $480 $570 $ B Ordering number DTPW218 DTPW224 DTPW236 DTPW248 DTPW260 DTPW272 List price per drive $340 $430 $600 $780 $960 $1, C Ordering number DTPW318 DTPW324 DTPW336 DTPW348 DTPW360 DTPW372 List price per drive $590 $760 $1,120 $1,470 $1,810 $2, D Ordering number DTPW418 DTPW424 DTPW436 DTPW448 DTPW460 DTPW472 List price per drive $1,010 $1,330 $1,970 $2,600 $3,250 $3, E Ordering number DTPW518 DTPW524 DTPW536 DTPW548 DTPW560 DTPW572 List price per drive $2,560 $3,360 $4,990 $6,610 $8,210 $9, F Ordering number DTPW618 DTPW624 DTPW636 DTPW648 DTPW660 DTPW672 List price per drive $4,920 $6,450 $9,520 $12,640 $15,640 $18,770 Coverage Terms: DrivePro-tection upgrades the product warranty by covering travel cost to the customer site and coverage of accidental damage to the product after installation, including the following: Momentary line or load anomalies such as lightning strikes. Accidental collision after installation Temporary exposure to moisture or corrosives Danfoss excludes coverage for failures due to product vandalism, miss-application, shipping or installation damage, chronic destructive site conditions or site catastrophes such as floods, fire, hurricanes or tornados. Coverage begins on the date of shipment and extends to the end of the contract period. Pricing applies to drives installed in the 48 adjacent states; Oahu, Hawaii; Anchorage, Alaska; and Canada. Danfoss will charge for Startup and/or service travel time over 1 hour each way; refer to the Field Service Rate price table on page 33 for pricing. October 2012 DPRO PL 37

38 DrivePro Professional Drive Support DrivePro Startup with Enhanced On-Site Service Warranty Drive order multiplier applies when purchased with drive Use this table for VLT AQUA & VLT Automation Drive, MCD 500 Soft Starter, Advance Harmonic Filter (AHF), Advanced Active Filter (AAF), Standard panel options (bypass, motor selection & line or load filters) HP Range (VT) Total coverage from date of shipment 208 VAC 460 / 600 VAC Frame 2 year 3 year 4 year 5 year 6 year A Ordering number ESW124 ESW136 ESW148 ESW160 ESW172 List price per drive $920 $990 $1,050 $1,110 $1, B Ordering number ESW224 ESW236 ESW248 ESW260 ESW272 List price per drive $1,020 $1,130 $1,240 $1,350 $1, C Ordering number ESW324 ESW336 ESW348 ESW360 ESW372 List price per drive $1,230 $1,450 $1,670 $1,880 $2, D Ordering number ESW424 ES W436 ESW448 ESW460 ESW472 List price per drive $1,580 $1,980 $2,380 $2,780 $3, E Ordering number ESW524 ESW536 ESW548 ESW560 ESW572 List price per drive $2,850 $3,870 $4,880 $5,880 $6,880 Use this table for Engineered Drives Systems (EDS - drives & panel packages), Low Harmonic Drive (LHD), Active Front End Drive (AFE), 12 Pulse Drive HP Range (VT) Total coverage from date of shipment 208 VAC 460 / 600 VAC Frame 2 year 3 year 4 year 5 year 6 year A B C D E Ordering number ESPW124 ESPW136 ESPW148 ESPW160 ESPW172 List price per drive $970 $1,060 $1,140 $1,210 $1,290 Ordering number ESPW224 ESPW236 ESPW248 ESPW260 ESPW272 List price per drive $1,100 $1,240 $1,380 $1,530 $1,670 Ordering number ESPW324 ESPW336 ESPW348 ESPW360 ESPW372 List price per drive $1,370 $1,660 $1,940 $2,220 $2,500 Ordering number ESPW424 ESPW436 ESPW448 ESPW460 ESPW472 List price per drive $1830 $2,350 $2,860 $3,390 $3,900 Ordering number ESPW524 ESPW536 ESPW548 ESPW560 ESPW572 List price per drive $3,480 $4,800 $6,120 $7,420 $8,720 Coverage Terms: Enhanced Service Warranty with Start-up combines SU service for one drive with a product warranty upgrade by covering travel cost (maximum of 2 hours) to the customer site. Coverage begins on the date of shipment and extends to the end of the contract period. Pricing applies to drives installed in the 48 adjacent states; Oahu, Hawaii; Anchorage, Alaska; and Canada. Danfoss will charge for Startup and/or service travel time over 1 hour each way; refer to the Field Service Rate price table on page 33 for pricing. 38 DPRO PL October 2012

39 DrivePro Professional Drive Support Enhanced On-Site Service Warranty Drive order multiplier applies when purchased with drive Use this table for VLT AQUA & VLT Automation Drive, MCD 500 Soft Starter, Advance Harmonic Filter (AHF), Advanced Active Filter (AAF), Standard panel options (bypass, motor selection & line or load filters) HP Range (VT) Total coverage from date of shipment 208 VAC 460 / 600 VAC Frame 2 year 3 year 4 year 5 year 6 year A Ordering number EWW124 EWW136 EWW148 EWW160 EWW172 List price per drive $170 $235 $295 $355 $ B Ordering number EWW224 EWW236 EWW248 EWW260 EWW272 List price per drive $265 $375 $485 $595 $ C Ordering number EWW324 EWW336 EWW348 EWW360 EWW372 List price per drive $475 $700 $915 $1,130 $1, D Ordering number EWW424 EWW436 EWW448 EWW460 EWW472 List price per drive $830 $1,230 $1,625 $2,030 $2, E Ordering number EWW524 EWW536 EWW548 EWW560 EWW572 List price per drive $2,100 $3,115 $4,130 $5,130 $6, F Ordering number EWW624 EWW636 EWW648 EWW660 EWW672 List price per drive $4,030 $5,950 $7,900 $9,770 $11,730 Use this table for Engineered Drives Systems (EDS - drives & panel packages), Low Harmonic Drive (LHD), Active Front End Drive (AFE), 12 Pulse Drive HP Range (VT) Total coverage from date of shipment 208 VAC 460 / 600 VAC Frame 2 year 3 year 4 year 5 year 6 year A B C D E F Ordering number EWPW124 EWPW136 EWPW148 EWPW160 EWPW172 List price per drive $230 $310 $390 $470 $540 Ordering number EWPW224 EWPW236 EWPW248 EWPW260 EWPW272 List price per drive $350 $490 $640 $780 $920 Ordering number EWPW324 EWPW336 EWPW348 EWPW360 EWPW372 List price per drive $620 $910 $1,190 $1,470 $1,750 Ordering number EWPW424 EWPW436 EWPW448 EWPW460 EWPW472 List price per drive $1,080 $1,600 $2,120 $2,640 $3,160 Ordering number EWPW524 EWPW536 EWPW548 EWPW560 EWPW572 List price per drive $2,730 $4,050 $5,370 $6,670 $7,970 Ordering number EWPW624 EWPW636 EWPW648 EWPW660 EWPW672 List price per drive $5,240 $7,740 $10,270 $12,710 $15,250 Coverage Terms: Enhanced Service Warranty upgrades the product warranty by covering travel cost to the customer site. Coverage begins on the date of shipment and extends to the end of the contract period. Pricing applies to drives installed in the 48 adjacent states; Oahu, Hawaii; Anchorage, Alaska; and Canada. Danfoss will charge for Start-up and/or service travel time over 1 hour each way; refer to the Field Service Rate price table on page 33 for pricing. October 2012 DPRO PL 39

40 General Conditions of Sale and Warranty These General Terms and Conditions of Sale ( Terms ) apply to all deliveries of products and services ( Products ) from Danfoss LLC or its Affiliates (each of which is referred to as Danfoss ) to any customer ( Customer ). In these Terms Affiliate shall mean any entity that directly or indirectly through one or more intermediaries, controls, is controlled by or is under common control by Danfoss LLC at such time. No terms and conditions other than these Terms shall be binding upon Danfoss and the Customer unless agreed in writing by both Danfoss and Customer. All terms and conditions contained in any prior communication which are different from or in addition to the Terms shall not be binding on Danfoss unless otherwise expressly agreed in writing by both Danfoss and Customer. 1. Confirmation of Order Danfoss shall not be deemed to have accepted an order until a written, including electronic, acceptance of the Customer s purchase order by Danfoss is received by Customer or Danfoss has received a written, including electronic, timely and unconditional acceptance by Customer of Danfoss quotation. 2. Terms of Delivery The Products are delivered F.O.B. Seller, [freight and insurance prepaid and add]. If the Customer does not provide written instructions, Danfoss may deliver the Products to Customer, at the risk and expense of Customer, by a transport method chosen by Danfoss. Unless otherwise agreed in writing, Danfoss may make delivery in installments. All installments will be separately invoiced and paid as billed without regard to subsequent deliveries. Failure to pay any installment when due will excuse Danfoss from making all future deliveries. 3. Shipment Delay If Danfoss does not ship on the promised date, Customer is entitled to request a reasonable, revised shipment date in writing without undue delay. No claims can be made by the Customer as a result of the delay. 4. Price Prices for Products do not include taxes or duties.danfoss reserves the right to adjust accepted prices for non-delivered Products in the event of alterations in rates of exchange, variations in costs of materials, a sub-supplier s price increases, changes in wages, state requisitions or similar conditions over which Danfoss has no or limited control. 5. Packing Disposable packing is not included in the price and will not be credited if returned. Cost of special boxing, export boxing, cartage or transfer expenses will be added to the invoice unless charges are shown to be included in the prices quoted. 6. Terms of Payment Invoices are payable in full 30 days following the invoice date unless other payments terms are agreed to in writing between Danfoss and the Customer, subject to approval and continuance of approval of credit by Danfoss. In the event that Danfoss does not approve credit to the Customer, or if at any time Danfoss reverses its prior approval of credit for any reason, terms of payment shall be C.O.D., or immediate partial, or full advance payment, or a combination of the foregoing methods, all as Danfoss may then, or thereafter from time to time, elect or specify. All payments shall be in U.S. dollars. Invoices not paid within 30 days of the invoice date are subject to an interest rate of the lesser of 1½% per month or the highest rate allowable under applicable law. 7. Group Set-off Danfoss and its Affiliates shall be entitled to set off their own claims against the Customer, in event of Customer s possible claims against any of said companies. 8. Product Information While Danfoss attempts to provide helpful and accurate information on the weight, dimensions, capacity, and performance capabilities of the Products in catalogues, literature, brochures and advertisements, and on its website, the Customer should not rely on any such information, and no such information is binding on Danfoss, unless explicit reference to the specific information in question is made in a written offer from Danfoss and/or a written order acceptance by Danfoss. Specific demands from the Customer are only binding if and to the extent they have been accepted by Danfoss in writing. 9. Proprietary Information and Confidentiality Any non-public information, including but not limited to, drawings, descriptions and any other technical documents which Danfoss makes available to the Customer ( Confidential Information ) shall remain the property of Danfoss and shall be treated as confidential by Customer and its representatives and must not, without the written consent of Danfoss, be copied, reproduced, or transferred to third parties or be used for other purposes than those intended when the Confidential Information was made available. Confidential Information shall be returned upon Danfoss request. 10. Alterations Danfoss reserves the right to make, without notice to Customer, alterations to a Product that do not materially affect agreed specifications or the Product s form, fit or function. 11. Limited Warranty 11a Danfoss warrants that VLT Variable Frequency Drives, AC VFD Panels and Harmonic Filters, except VLT Micro Drive, Decentral Drives, Soft Starters and their options to be free from defects in material and workmanship for 18 months from date of shipment. DrivePro Plus units are warranted for 36 months from date of shipment. 11b Danfoss warrants that VLT Micro Drive, Decentral Drives and Soft Starters and their options will be free from defects in materials and workmanship for a period of 12 months from date of shipment. 11c Accessories for all drives ordered for shipment subsequent to the drive and all items mounted separate from the drive will be free from defects in materials or workmanship for a period of 12-month, from date of shipment. 11d All drives parts will be free from defects in materials or workmanship for a period of 6 months from date of shipment. This warranty shall be voided if the article in question is improperly installed, applied, operated or maintained; subjected to overload, misuse, negligence or an accident; or repaired or altered outside of the Danfoss factory or by anyone other than an authorized Danfoss service partner under direction of Danfoss. Products manufactured by others, but supplied by Danfoss as part of a Danfoss Product, are not warranted by Danfoss, and Customer s sole recourse if any such product should fail shall be under the warranty, if any, of such other manufacturer. Fuses are warranted only when a defect or malfunction of the Product or its components are found to be the cause of the fuse failure. Customer s sole and exclusive remedy against Danfoss and Danfoss only obligation, for breach of warranty, shall be, at Danfoss option, the repair or replacement (with either a refurbished or new Product) of any Product that on Danfoss examination is found to be defective at the time of delivery due to faulty workmanship and/ or defective material, but only if the Customer submits a claim in writing to Danfoss within the warranty period. When making a warranty claim, the Customer must forward the Product to Danfoss in a manner to be agreed upon between Customer and Danfoss with a description of the reason for returning the Product. Freight and insurance will be paid by the Customer. If Danfoss determines that the Product is not defective due to faulty workmanship and/or defective material or that the warranty has been voided, the Product shall be returned to the Customer, if the Customer requests. In such case, freight and insurance shall be paid by the Customer. If Danfoss ascertains that the Product is defective due to faculty workmanship and/ or defective material, Danfoss shall send the repaired Product or a replacement Product to the Customer. Danfoss may choose the method of delivery and will pay freight and insurance. Products or product parts which have been replaced shall be the property of and retained by Danfoss. The Customer is responsible for repackaging Products returned in suitable packing material to prevent damage in transit. Danfoss may elect to provide service personnel at Customer s premises to affect Product repair or replacement covered by the terms of the warranty. Danfoss may pay for a portion or all of the travel time and expense for Products located in the 48 adjacent states; island of Oahu, Hawaii; 40 TERMS PL October 2012

41 Anchorage, Alaska; and major metropolitan areas of Canada. For products located in the rest of Hawaii, Alaska, Canada and other countries, travel time and travel expenses will be billed to the Customer. 12. Disclaimer of Warranties EXCEPT FOR THE WARRANTIES STATED IN SECTION 11, THE PRODUCTS ARE SUPPLIED AS IS, WHERE IS AND WITH ALL FAULTS. DANFOSS DISCLAIMS ALL OTHER WARRANTIES WITH RESPECT TO THE PRODUCTS, EITHER EXPRESS OR IMPLIED, ARISING BY OPERATION OF LAW, COURSE OF DEALING, USAGE OF TRADE OR OTHERWISE, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 13. Indemnification Customer shall indemnify, defend and hold Danfoss harmless from all claims, including but not limited to all claims filed by third parties, for injuries, harms, losses or damages of any kind, (a) caused by or resulting from, (i) the Product after it has been delivered, (ii) the improper use, repair, maintenance or operation of the Product by Customer, (iii) the failure of Customer to adequately train personnel in the operation of the Product, or (iv) the Customer s failure to comply with applicable laws or regulations or (b) to products manufactured by the Customer or to products of which the Customer s products form a part. The Customer consents to the jurisdiction of any court or arbitral tribunal in which any third party files a claim for injuries, harms, losses or damages allegedly caused by any Product sold to Customer. 14. Limitation of Liability IN NO EVENT SHALL DANFOSS BE LIABLE FOR ANY SPECIAL, INDIRECT, CONSEQUENTIAL, PUNITIVE OR EXEMPLARY DAMAGES OR LOSSES ARISING OUT OF ANY BREACH OF WARRANTY, FAULTY PRODUCT, DELAY IN THE DELIVERY OF THE PRODUCT, PRODUCT LIABILITY, FAILURE TO WARN, RECALL OR OTHERWISE, IRRESPECTIVE OF THE CAUSE, INCLUDING BUT NOT LIMITED TO, LOSS OF PRODUCTION, LOSS OF PROFIT AND LOSS OF GOODWILL. 15. Notice of Claims Claims or complaints as to defects and/or delay in delivery of the Products or other claims shall be submitted in writing by Customer to Danfoss without undue delay. 16. Intellectual Property Rights If the Product is delivered with embedded software, Customer obtains a non-exclusive, software license in form of a right to use the software solely for the purposes set out in the applicable specification of the Product. Aside from this, Customer obtains no rights in form of license, patent, copyright, trademark or other proprietary right connected to the Products. Customer shall not obtain any rights to source codes to such software. Danfoss, at its election, may defend any suit or proceeding brought against Customer as far as the same is based on a claim that any Product of Danfoss design furnished hereunder or any part thereof, constitutes an infringement of any United States or Canadian patent, if notified promptly in writing and given authority, information and assistance for the defense of the same and if such alleged infringement is not the result of the design or other special requirements specified by Customer or the application or use to which such Product is put to use by Customer or others. In the event that Danfoss elects to defend such suit or proceeding, Danfoss will pay all damages and costs awarded in such suit or proceeding against Customer. In the event that such Product or part in such suit is held to infringe any such patent and use thereof is enjoined, Danfoss will, at its option, (a) procure Customer with the right to continue use of such Product or part, (b) replace same with non-infringing Product(s) or parts, (c) modify the same so that it becomes non-infringing, or (d) remove said Product or part and refund the purchase price and the transportation and installation costs thereof. The foregoing states the entire liability of Danfoss to Customer for patent infringement. 17. Export Customer is hereby advised and put on notice that Products may be subject to export controls and regulations of the United States, another country of manufacture or a country of transshipment, and export may require a valid export license. Danfoss acceptance of Customer s order and delivery of the Products is expressly conditioned on compliance by Customer with all applicable export controls. Danfoss is under no obligation to sell or deliver the Products until all required export licenses have been granted. No Products sold to Customer may be exported unless such export complies fully with all applicable export regulations. Customer shall be responsible for obtaining all required export licenses and for all expenses of obtaining such licenses. 18. Prohibition on Resale and Use for Certain Purposes Danfoss Products are produced exclusively for civilian use. Customer is not allowed to use or to resell the Products for purposes which have any connection to chemical, biological or nuclear weapons or for missiles which are capable of delivering such weapons. Customer is not allowed to sell the Products to persons, companies or any other kind of organization if Customer has knowledge of or suspects that said persons or entities are related to any kind of terrorist or narcotics activities. The Products may be subject to legal regulations and restrictions and may therefore be subject to restrictions in case of sale to countries/customers covered by export and import ban. These restrictions shall be observed in case of resale of the Products to such countries/ customers. Customer is not allowed to resell the Products if there is doubt or suspicion that the Products can be used for the purposes mentioned in the preceding paragraph. If Customer receives knowledge of or suspects that the conditions in this clause have been violated, Customer shall immediately inform Danfoss. 19. Force Majeure Danfoss is entitled to cancel orders or suspend or delay delivery of Products and will not be liable for such cancellation, suspension, or any nondelivery, faulty or delayed delivery which partly or wholly is caused by circumstances beyond Danfoss control, including, but not limited to, riots, civil unrest, war, terrorism, fire, insurrection, requisition, seizure, embargo or defects or delays in deliveries by sub-contractors, strikes, lockouts, slow downs, lack of transportation, scarcity of materials, accidents in product testing, and insufficient supplies of energy. Any of Customer s contractual rights are suspended or become void in any such circumstances referred to in this clause. Customer is not entitled to any kind of damages or to make a claim whatsoever in case of cancellation or delayed delivery due to such circumstances. 20. Global Compact Danfoss has joined the United Nations Global Compact initiative which means that Danfoss has undertaken to live up to 10 principles on human rights, employees rights, the environment and corruption. These principles are listed in Danfoss Code of Conduct for Suppliers to be seen on Therefore Danfoss encourages the Customer to comply with these fundamental principles. For further information on Global Compact: unglobalcompact.org 21. Partial Invalidity If one or more of the terms and conditions in these Terms or any part of a term is deemed invalid, unenforceable, illegal or inoperable, the validity, enforceability, legality or operability of all further terms and conditions shall not be affected or diminished thereby. 22. Disputes Any dispute between the parties concerning or arising from (a) a purchase of a Product or (b) any damages, injuries, losses or harms allegedly caused by any Product shall be decided under Wisconsin law. Any such dispute which the parties themselves are unable to resolve shall be referred to and settled by arbitration in Chicago, Illinois under the American Arbitration Association s Commercial Arbitration Rules ( AAA Rules ) by one arbitrator appointed in accordance with said AAA Rules. The Parties may refer the enforcement of any arbitral award to any competent court. English shall be the language to be used in the arbitration proceeding unless otherwise agreed between the parties. The arbitration proceedings and the arbitral award shall be confidential and involved persons on both sides are pledged to secrecy. October 2012 TERMS PL 41

42 EnVisioneering As a world leader in components and solutions, Danfoss meets our customers challenges through EnVisioneering. This approach expresses our views on engineering innovation, energy efficiency, environmental responsibility and sustainable business growth that create strong customer partnerships. This vision is realized through a global production, sales, and service network focused on refrigeration, air conditioning, heating and water, and motion control. Through EnVisioneering, Danfoss is Making Modern Living Possible. Danfoss EnVisioneering : Engineered solutions to improve performance and profitability Energy efficiency to meet higher standards and to lower operating costs Environmental sustainability to provide a financial and social payback Engaged partnerships to foster trust, reliability, and technological superiority Danfoss can accept no responsibility for possible errors in catalogs, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss VLT Drives 4401 N. Bell School Rd. Loves Park, IL 61111, USA Phone: Fax: Danfoss VLT Drives 8800 W. Bradley Rd. Milwaukee, WI 53224, USA Phone: Fax: Copyright 2012 by Danfoss 10/12 175R5515

43 MAKING MODERN LIVING POSSIBLE. Section II VLT General Purpose Products Price List Effective June 1, 2012

44 Danfoss General Purpose Products Contents VLT Micro Drive...II-3 VLT 2800 Drive...II-4 VLT 2800 Drive Options and Accessories...II-5 VLT Drive Accessories... II-15 MCD 100 Soft Starter... II-16 MCD 200 Soft Starter...II-17 MCD 500 Soft Starter... II-20 FCM 300 Series... II-22 FCD 300 Decentral Drive... II-24 General Conditions of Sale and Warranty... II-26 Freight Options Danfoss offers three freight options: 1. Prepay and do not add Eliminates the need for customers to select a carrier and manage separate freight invoices. Danfoss will select a non-expedited, ground carrier. All shipments are F.O.B. point of shipment. AHF Filters and MCD 500 Soft Starters Models Net price/unit Conditions FLA and demonstration unit amp amp $65 NET 48 adjacent states $110 NET AK, HI, and Canada* $120 NET 48 adjacent states $220 NET AK, HI, and Canada* $550 NET 48 adjacent states $1,100 NET AK, HI, and Canada* VLT 2800, VLT Micro, drive accessories (shipped separately from the drive), spare parts General Policy Information Minimum Order All orders are subject to a minimum billing of $100 NET. For information and Discount Schedule, please contact your Danfoss Representative or the factory. Terms NET 30 Days Prices are subject to change without notice. Freight Danfoss reserves the right to select the freight carrier unless specified by the customer. Designations: All prices are factory list prices in US$ = Not available nc = Standard, no charge Models Net price/package Conditions All bare drives, accessories and parts Drives with standard option panels $20 NET 48 adjacent states packages $40 NET AK, HI, and Canada* $65 NET 48 adjacent states $110 NET AK, HI, and Canada* Danfoss will package multiple parts and accessories in a single package when possible. * Customs broker fees for Canada: $50 per shipment, G.S.T. additional. Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a broker and handle the brokerage fees directly. 2. Collect The customer is responsible for selecting the carrier and indicating their choice on the purchase order. Danfoss will schedule the pick-up. The customer is responsible for paying the carrier for the shipment. 3. Prepay and add Available for the following shipments: Expedited shipments Products such as custom panels and others not listed above Bulk shipments of spare parts Shipment to regions other than those listed above Shipments that require specialized packaging or transport types The customer may select a carrier or allow Danfoss to make the selection. Danfoss will pay the freight at the time of shipment and invoice the customer separately at the time of invoicing from the carrier. II-2 06/01/12

45 VLT Micro Drive FC 51 MICRO VAC Single Phase NEMA Size 1 230V Input Output Chassis/IP20 Heat Output Order HP Current Current W H D Frame Watts Number List 1/ F0001 $205 1/ M F0002 $ F0003 $ M F0005 $ M F0007 $400 FC 51 MICRO VAC Three Phase NEMA Size 1 230V Input Output Chassis/IP20 Heat Output Order HP Current Current W H D Frame Watts Number List 1/ F0008 $205 1/ M F0009 $ F0010 $ M F0012 $ F0014 $ M F0016 $475 M1 M2 M3 M4 M5 FC 51 MICRO VAC Three Phase NEMA 460V Input Output Chassis/IP20 Heat Output Order Size HP Current Current W H D Frame Watts Number List 1/ F0017 $ M F0018 $ F0020 $ M F0022 $ F0024 $ F0026 $ M F0028 $ F0030 $ F0058 $1, M F0059 $1, F0060 $1, M F0061 $2,010 Options Description Order Number List VLT LCP 11 w/o potentiometer 132B0100 $25 VLT LCP 12 with potentiometer 132B0101 $25 VLT LCP Blank Cover 132B0131 $25 Remote Mounting Kit for LCP 132B0102 $15 NEMA 1 kit for M1 frame 132B0103 $10 NEMA 1 kit for M2 frame 132B0104 $11 NEMA 1 kit for M3 frame 132B0105 $12 NEMA 1 kit for M4 frame 132B0120 $22 NEMA 1 kit for M5 frame 132B0121 $25 De-coupling plate kit for M1 and M2 frames 132B0106 $10 De-coupling plate kit for M3 frame 132B0107 $10 Decoupling kit for M4 and M5 132B0122 $10 IP21 for M1 frame 132B0108 $20 IP21 for M2 frame 132B0109 $25 IP21 for M3 frame 132B0110 $30 DIN rail mounting kit for M1 132B0111 $10 LCP 12 with potentiometer Remote mounting kit LCP blank cover MCC Line FIlter Line Filter MCC 107 Option for FC51 Order Number List M v 1ø HP 130B2522 $80 M v 1ø - 1 HP 130B2533 $80 M v 3ø HP 130B2523 $80 M v 1ø - 2 HP 130B2525 $135 M v 3ø - 2 HP 130B2524 $135 M v 3ø HP & v 3ø - 3 HP 130B2526 $135 M v 1ø - 3 HP 130B2530 $165 M v 3ø - 4 HP & v 3ø HP 130B2528 $165 M v 3ø - 3 HP & v 3ø - 5 HP 130B2531 $165 M v 3ø - 5 HP & v 3ø - 10 HP 130B2527 $165 M v 3ø HP 130B2529 $165 FC51 Terminal Cover with RS485 Plug and Ground Screw Order Number List M1 Frame 132B0126 $5 M2 Frame 132B0127 $5 M3 Frame 132B0128 $5 M4 Frame 132B0129 $5 M5 Frame 132B0130 $6 06/01/12 II-3

46 VLT 2800 Drive How to Order: Select one item from each of the feature code blocks to complete a part number. [1] [2] [3] [4] [5] Order Example: VLT P- D2 -B20- ST - R0 -DB - F00 Fieldbus Option F00 Without Fieldbus F10 With Profibus DP (3 MB) F12 With Profibus DP (12 MB) F30 With DeviceNet [1] Power Size* HP HP HP HP HP HP HP HP HP HP HP HP HP [2] AC Line Supply D2** 230 VAC, 1Ø or 3Ø (0.5 to 2 HP only) S2*** 230 VAC, 1Ø (0.5 to 2 HP only) T VAC, 3Ø (3 and 5 HP only) T VAC, 3Ø (0.75 to 25 HP) [3] Hardware ST Standard SB Standard with Brake [4] RFI Filter R0 Without Filter R1 With Built-in 1A Filter R3 With Built-in 1B Filter [5] Fieldbus Options F00 Without Fieldbus F10 With Profibus DP F12 With Profibus DP (12 MB) F30 With DeviceNet * Power sizes 2803 thru 2875 provided in a protected chassis (IP 20); 2880 thru 2882 are NEMA 1 ** Cannot be ordered with RFI Filter. *** Must be ordered with RFI Filter HP Output Amps List Price Brake RFI Option Fieldbus Option V - Dual 1 or 3 Phase F00 F10 F12 F30 VLT 2803 D $415 $30 std $250 $225 $195 VLT 2805 D $439 $30 std $250 $225 $195 VLT 2807 D $450 $30 *D2 Units have std $250 $225 $195 VLT 2811 D $500 $40 std $250 $225 $195 VLT 2815 D $545 $40 no RFI option. std $250 $225 $195 VLT 2822 D $650 N/A std $250 $225 $195 VLT 2840 D $1,150 N/A std $250 $225 $195 *D2 - Unit cannot be ordered with RFI filter V 1 phase R1 F00 F10 F12 F30 VLT 2803 S $550 $30 $135 std $250 $225 $195 VLT 2805 S $574 $30 $135 std $250 $225 $195 VLT 2807 S $585 $30 $135 std $250 $225 $195 VLT 2811 S $645 $40 $145 std $250 $225 $195 VLT 2815 S $690 $40 $145 std $250 $225 $195 *S2 - Unit can only be ordered with RFI filter V 3 phase R0 R1 F00 F10 F12 F30 VLT 2822 T $646 $40 std $145 std $250 $225 $195 VLT 2840 T $820 $55 std $155 std $250 $225 $ V 3 Phase R0 R1 R3 F00 F10 F12 F30 VLT 2805 T $390 $30 $- $135 n/a std $250 $225 $195 VLT 2807 T $440 $30 $- $135 n/a std $250 $225 $195 VLT 2811 T $485 $40 $- $145 n/a std $250 $225 $195 VLT 2815 T $535 $40 $- $145 n/a std $250 $225 $195 VLT 2822 T $630 $40 $- $145 n/a std $250 $225 $195 VLT 2830 T4 4 7 $730 $55 $- $160 n/a std $250 $225 $195 VLT 2840 T $799 $55 $- $160 n/a std $250 $225 $195 VLT 2855 T $930 $70 $- $205 n/a std $250 $225 $195 VLT 2875 T $1,075 $70 $- $205 n/a std $250 $225 $195 VLT NEMA 1 T $1,375 $100 $- n/a $245 std $250 $225 $195 VLT NEMA 1 T $1,620 $100 $- n/a $245 std $250 $225 $195 VLT NEMA 1 T $2,050 $100 $- n/a $245 std $250 $225 $195 II-4 06/01/12

47 VLT 2800 Drive Options and Accessories Exceptional performance has made the VLT 2800 the one to beat among general purpose drives. Over the years, the VLT 2800 has proven to be dependable, versatile and easy to operate and commision. Packed with functionality at an attractive price, the VLT 2800 can be a reliable asset in many applications. Power Size* HP HP HP HP HP HP HP HP HP HP HP HP HP Accessory List Prices List Price Local Control Panel 175N0131 LCP-2 keypad $ Z0850 LCP remote mounting kit $80 175Z0929 Cable only (10 ) $40 NEMA 1 Kit 195N1900 For VLT $31 195N1901 For VLT ; VLT 2840 (460V only) $30 195N1902 For VLT 2840 (230V only); VLT 2855 and 2875 $75 Add on modules 195N3100 RFI B1/LC Filter For VLT (230V); VLT (460V) $ N3101 RFI B1/LC Filter For VLT (230V); VLT (460V) $ N3103 RFI B1 Filter For VLT (230V); VLT (460V) $ N3110 Motor Coil For VLT (230V); VLT (460V) $368 RFI Filter R0 = Without Filter R1 = With Built-in A1 Filter R3 = With Built-in B1 Filter Fieldbus Options F00 = Without Fieldbus F10 = With Profibus DP (3 MB) F12 = With Profibus DP (12 MB) F10 = With DeviceNet VLT 2800 Dimensions VLT (1/2-2HP) VAC VLT 2822 (T2) 3HP / 3ø VAC VLT (3/4-2HP) VAC VLT (3-5 HP) VAC Protected Chassis / IP20 [mm] Protected Chassis / IP20 [mm] Height 7.9 in. [200] 10.5 in. [268] Width 3.0 in. [75] 3.5 in. [90] Depth 6.6 in. [168] 6.6 in. [168] VLT 2822 (3HP) 1ø/ 3ø VAC VLT 2840 (T2) (5HP) 3ø VAC VLT 2840 (5HP) 1ø/3 ø VAC VLT ( HP) VAC VLT (15-25HP) VAC Protected Chassis / IP20 [mm] Protected Chassis / IP20 [mm] Height 10.5 in. [268] 19.9 in. [505] Width 5.5 in. [140] 7.9 in. [200] Depth 6.6 in. [168] 9.6 in. [244] AC Line Voltage D2** 230 VAC, 1Ø or 3Ø, (0.5 to 5 HP only) S2 230 VAC, 1Ø (0.5 to 2 HP only) T VAC, 3Ø (3 5 HP only) T VAC, 3Ø (0.75 to 25 HP) * Power sizes provided in a protected chassis (IP 20); are NEMA 1 ** Cannot be ordered with RFI Filter Must be ordered with RFI Filter 06/01/12 II-5

48 VLT Drive Sine-Wave Filters Sine-Wave Filters IP00 3x VAC IP20 / 23 3x VAC IP00 3x VAC IP20/23 3x VAC Order Output Current Rating Dimensions ( in ) Filter Loss @100Hz Height Width Depth (w) List Price 130B2404 MCC101A2K5T3E00A $ B2406 MCC101A4K5T3E00A $ B2408 MCC101A8K0T3E00A $ B2409 MCC101A10KT3E00A $ B2411 MCC101A17KT3E00A $ B2412 MCC101A24KT3E00A $ B2413 MCC101A38KT3E00A $1, B2281 MCC101A48KT3E00A $1, B2282 MCC101A62KT3E00A $1, B2283 MCC101A75KT3E00A $2, B3179 MCC101A115T3E00B $3, B3182 MCC101A180T3E00B $4, B3184 MCC101A260T3E00B $5, B3186 MCC101A410T3E00B $8, B3188 MCC101A510T3E00B $9, B3191 MCC101A660T3E00B $12, B3193 MCC101A800T3E00B $15,700 Order Output Current Rating Dimensions ( in ) Filter Loss @100Hz Height Width Depth (w) List Price 130B2439 MCC101A2K5T3E20A $ B2441 MCC101A4K5T3E20A $ B2443 MCC101A8K0T3E20A $ B2444 MCC101A10KT3E20A $ B2446 MCC101A17KT3E20A $ B2447 MCC101A24KT3E20A $ B2448 MCC101A38KT3E20A $1, B2307 MCC101A48KT3E20A $2, B2308 MCC101A62KT3E20A $2, B2309 MCC101A75KT3E20A $3, B3181 MCC101A115T3E23B $4, B3183 MCC101A180T3E23B $6, B3185 MCC101A260T3E23B $7, B3187 MCC101A410T3E23B $10, B3189 MCC101A510T3E23B $12, B3192 MCC101A660T3E23B $15, B3194 MCC101A800T3E23B $18,995 Order Output Current Rating Dimensions ( in ) Filter Loss @100Hz Height Width Depth (w) List Price 130B3195 MCC101A13KT7E00B $1, B4112 MCC101A28KT7E00B $2, B4114 MCC101A45KT7E00B $4, B4116 MCC101A76KT7E00B $6, B4118 MCC101A115T7E00B $7, B4121 MCC101A165T7E00B $9, B4125 MCC101A260T7E00B $12, B4129 MCC101A360T7E00B $15, B4152 MCC101A430T7E00B $19, B4154 MCC101A530T7E00B $20, B4156 MCC101A660T7E00B $22,995 Order Output Current Rating Dimensions ( in ) Filter Loss @100Hz Height Width Depth (w) List Price 130B3196 MCC101A13KT7E20B $1, B4113 MCC101A28KT7E20B $3, B4115 MCC101A45KT7E20B $5, B4117 MCC101A76KT7E23B $7, B4119 MCC101A115T7E23B $9, B4124 MCC101A165T7E23B $11, B4126 MCC101A260T7E23B $14, B4151 MCC101A360T7E23B $18, B4153 MCC101A430T7E23B $22, B4155 MCC101A530T7E23B $24, B4157 MCC101A660T7E23B $27,885 II-10 06/01/12

49 VLT Drive Sine-Wave Filters Wall Mounted Sine-Wave Filter Order Number Order Number IP00 IP20 Accessory Bag List Price 130B B B B B B B0385 $40 130B B B B B B B B B0386 $45 130B B B B B B B0387 $85 130B B B B B4175 $60 130B B B4176 $60 130B B B4127 $60 Accessories L- Shaped Voltage Current Enclosure Order Number L-shape List Price B3179 N/A B3181 N/A B3182 N/A B3183 N/A B B B3137 $ V B B B B B3138 $ B B B B B B B B B4113 $ B B4115 N/A B B B B V B B B B B3137 $ B B B B B3138 $ B B B B B3139 $490 Cable Glands for Floor Standing Filters Nom. filter current rating ( /460/600/690V) [A] Filter Code Number Spare part no. List Price 315/303/242/ B /443/344/ B /590/500/ B B4178 $ /780/630/ B2848 Protective earth (PE) grounding Plate for IP00 and IP20 wall mounted filters. The accessory bag also includes all necessary screws and cable holders. Accessories Order Number List Price 130B3137 l-shape Terminal Kit 1-2 holes 10.5mm $75 130B3138 l - Shape Terminal Kit 2-4 holes 13 mm $ B4178 Cable Glands Floor Mounted IP23 Filters $ B4175 Terminal Kit for 40 Amp for dv/dt Filter $25 130B4176 Terminal Kit for 80/105 Amp for dv/dt Filter $40 130B4177 Terminal Kit 160 Amp for DV/dt Filter $45 Nom. filter current rating ( /460/600/690V) [A] Filter Code Number Accessory Bag List Price 44/40/32/27 130B B4175 $40 130B /80/58/54 130B B4176 $60 130B /105/94/86 130B B4176 $60 130B /160/131/ B B4127 $ B2845 Voltage Current V V IP Order Number L-shape List Price B B B B B B B B B4178 $ B B B B B B B B B B B4175 $ B B B B B B B B B B B B4178 $ B B B B B B B /01/12 II-11

50 VLT Drive dv/dt Filters dv/dt Filters IP00 IP20/23 Current rating (Amp) Dimensions (in) Order Number Typecode 60Hz 50Hz 60Hz 50Hz 60Hz 50Hz Filter Losses (W) H W D List Price 130B2835 MCC102A40KTME00B $ B2838 MCC102A80KTME00B $ B2841 MCC102A105TME00B $1, B2844 MCC102A160TME00B $1, B2847 MCC102A303TME00B $2, B2849 MCC102A460TME00B $2, B2851 MCC102A645TME00B $3, B2853 MCC102A800TME00B $5,275 60Hz 50Hz Current rating (Amp) 60Hz 50Hz Dimensions (in) Filter Order Number Typecode 60Hz 50Hz Losses (W) H W D List Price 130B2836 MCC102A40KTME20B $ B2839 MCC102A80KTME20B $1, B2842 MCC102A105TME20B $1, B2845 MCC102A160TME20B $2, B2848 MCC102A303TME23B $2, B2850 MCC102A460TME23B $3, B2852 MCC102A645TME23B $4, B2854 MCC102A800TME23B $8,450 Range: 0.75kW-1.2MW ( HP) Mains voltage: T2 (up to 45kW / 60 HP) T4-7 (up to 1.2MW / 1600 HP) Enclosure: IP00 and IP20/23 Max. Temp. 45C Voltage drop: 0.5% II-12 06/01/12

51 VLT Drive AHF Advanced Harmonic Filters 440V - 480VAC, 60 Hz Order Number Order Number Typecode Typecode List Price Enclosure AHF 10 AHF 5 AHF 10 AHF 5 AHF 10 AHF 005 IP00 130B B1787 AHF-DA A AHF-DB A $1,271 $1,478 IP20 130B B1752 AHF-DA A AHF-DB A $1,495 $1,673 IP00 130B B1788 AHF-DA A AHF-DB A $1,312 $1,731 IP20 130B B1753 AHF-DA A AHF-DB A $1,514 $1,933 IP00 130B B1789 AHF-DA A AHF-DB A $1,409 $1,939 IP20 130B B1754 AHF-DA A AHF-DB A $1,634 $2,133 IP00 130B B1790 AHF-DA A AHF-DB A $1,622 $2,197 IP20 130B B1755 AHF-DA A AHF-DB A $1,841 $2,417 IP00 130B B1791 AHF-DA A AHF-DB A $1,855 $2,378 IP20 130B B1756 AHF-DA A AHF-DB A $2,105 $2,579 IP00 130B B1792 AHF-DA A AHF-DB A $1,924 $2,524 IP20 130B B1757 AHF-DA A AHF-DB A $2,224 $2,782 IP00 130B B1793 AHF-DA A AHF-DB A $2,377 $3,007 IP20 130B B1758 AHF-DA A AHF-DB A $2,632 $3,312 IP00 130B B1794 AHF-DA A AHF-DB A $2,813 $3,389 IP20 130B B1759 AHF-DA A AHF-DB A $3,069 $3,650 IP00 130B B1795 AHF-DA A AHF-DB A $3,033 $3,805 IP20 130B B1760 AHF-DA A AHF-DB A $3,290 $4,079 IP00 130B B1796 AHF-DA A AHF-DB A $3,474 $4,637 IP20 130B B1761 AHF-DA A AHF-DB A $3,762 $4,252 IP00 130B B1797 AHF-DA A AHF-DB A $4,008 $5,257 IP20 130B B1762 AHF-DA A AHF-DB A $4,282 $5,664 IP00 130B B1798 AHF-DA A AHF-DB A $4,605 $6,219 IP20 130B B1763 AHF-DA A AHF-DB A $4,894 $6,109 IP00 130B B1799 AHF-DA A AHF-DB A $5,121 $6,793 IP20 130B B1764 AHF-DA A AHF-DB A $5,391 $6,719 IP00 130B B1900 AHF-DA A AHF-DB A $5,918 $7,974 IP20 130B B1765 AHF-DA A AHF-DB A $6,350 $6,883 IP00 130B B2200 AHF-DA A AHF-DB A $7,116 $9,638 IP20 130B B1766 AHF-DA A AHF-DB A $7,564 $9,875 IP00 130B B2257 AHF-DA A AHF-DB A $8,901 $11,306 IP20 130B B1768 AHF-DA A AHF-DB A $9,419 $11,973 IP00 130B B3168 AHF-DA A AHF-DB A $10,031 $12,269 IP20 130B B3167 AHF-DA A AHF-DB A $10,816 $13,454 IP00 130B B2259 AHF-DA A AHF-DB A $11,533 $13,936 IP20 130B B1769 AHF-DA A AHF-DB A $12,088 $14,987 NEMA 1 Kit Option Order NEMA 1 Enclosure AHF Dimensions List Enclosure Number a b c d e Price X1 130B $475 X2 130B $495 X3 130B $650 X4 130B $795 X5 130B $895 X6 130B $1,150 X7 130B $1,475 X8 130B $1,975 Chassis Dimensions Dimensions Enclosure H W D X X X X X X X X Backplate Option Order Enclosure Number List Price X1 130B3283 $70 X2 130B3284 $85 X3 130B3285 $115 X4 130B3286 $155 X5 130B3287 $199 X6 130B3287 $375 X7 130B3288 $375 X8 130B3288 $375 Note: All dimensional information is in Inches. 06/01/12 II-13

52 VLT Drive AHF Advanced Harmonic Filters AHF VAC, 60 Hz Order Number Order Number Typecode Typecode List Price Enclosure AHF 10 AHF 5 AHF 10 AHF 5 AHF 10 AHF 005 IP00 130B B5261 AHF-DA A AHF-DB A $2,771 $3,746 IP20 130B B5246 AHF-DA A AHF-DB A $3,071 $3,971 IP00 130B B5262 AHF-DA A AHF-DB A $3,071 $4,271 IP20 130B B5247 AHF-DA A AHF-DB A $3,296 $4,571 IP00 130B B5263 AHF-DA A AHF-DB A $3,521 $4,646 IP20 130B B5248 AHF-DA A AHF-DB A $3,746 $4,946 IP00 130B B5264 AHF-DA A AHF-DB A $3,971 $5,321 IP20 130B B5249 AHF-DA A AHF-DB A $4,271 $5,621 IP00 130B B5265 AHF-DA A AHF-DB A $4,796 $6,371 IP20 130B B5250 AHF-DA A AHF-DB A $5,063 $6,671 IP00 130B B5266 AHF-DA A AHF-DB A $5,246 $7,046 IP20 130B B5251 AHF-DA A AHF-DB A $5,621 $7,346 IP00 130B B5267 AHF-DA A AHF-DB A $5,846 $8,096 IP20 130B B5252 AHF-DA A AHF-DB A $6,146 $8,396 IP00 130B B5268 AHF-DA A AHF-DB A $6,521 $8,696 IP20 130B B5253 AHF-DA A AHF-DB A $6,863 $9,071 IP00 130B B5269 AHF-DA A AHF-DB A $7,196 $9,746 IP20 130B B5254 AHF-DA A AHF-DB A $7,496 $10,196 IP00 130B B5270 AHF-DA A AHF-DB A $8,021 $10,646 IP20 130B B5255 AHF-DA A AHF-DB A $8,321 $10,946 IP00 130B B5271 AHF-DA A AHF-DB A $8,471 $10,946 IP20 130B B5256 AHF-DA A AHF-DB A $8,771 $11,396 IP00 130B B5272 AHF-DA A AHF-DB A $10,271 $12,746 IP20 130B B5257 AHF-DA A AHF-DB A $10,496 $13,271 IP00 130B B5273 AHF-DA A AHF-DB A $11,771 $14,696 IP20 130B B5258 AHF-DA A AHF-DB A $12,296 $15,221 IP00 130B B5274 AHF-DA A AHF-DB A $12,596 $15,446 IP20 130B B5259 AHF-DA A AHF-DB A $13,121 $15,971 IP00 130B B5275 AHF-DA A AHF-DB A $14,921 $18,221 IP20 130B B5260 AHF-DA A AHF-DB A $14,996 $18,746 IP00 130B5244 n/a AHF-DA A n/a $16,046 n/a IP20 130B5227 n/a AHF-DA A n/a $16,496 n/a IP00 130B5245 n/a AHF-DA A n/a $17,021 n/a IP20 130B5228 n/a AHF-DA A n/a $17,546 n/a NEMA 1 Kit Option Order NEMA 1 Enclosure AHF Dimensions List Enclosure Number a b c d e Price X3 130B $650 X4 130B $795 X5 130B $895 X6 130B $1,150 X7 130B $1,475 X8 130B $1,975 Backplate Option Order Enclosure Number List Price X3 130B3285 $115 X4 130B3286 $155 X5 130B3287 $199 X6 130B3287 $375 X7 130B3288 $375 X8 130B3288 $375 Chassis Dimensions Dimensions Enclosure H W D X X X X X X Note: All dimensional information is in Inches. II-14 06/01/12

53 VLT Drive Brake Accessories Resistors PC Software Order Number Product Type Description List Price 130B1000 MCT 10 MCT 10 set-up software (advanced version) $275 MCT 10 software offers advanced programming functionality for all Danfoss drive products, greatly reducing programming and setup time. Download from: America/BusinessAreas/DrivesSolutions Project folders can also store user-defined files such as PDFs, CAD drawings, or Word documents. MCT 10 is the one PC tool for all your drive programming tasks. MCT 10 Basic (available free of charge from the Danfoss web site) allows access to a finite number of drives with limited functionality. The Advanced edition, offering a higher level of functionality, is available from your Danfoss sales partner. Drives are managed in a standard folderbased user interface that s familiar and easy to understand. Parameter settings for each drive are contained in a single file, allowing easy duplication of parameter sets between drives. MCT 10 Comparison MCT 10 Basic MCT 10 Advanced Number of projects Unlimited Unlimited Number of drives per project 4 Unlimited Logging and scope functions 2 channels 8 channels Real time logging from drive N/A 4 channels Alarm display View alarm history Alarm history in saved projects Motor database N/A Yes PC Software Order Number Type Description List Price 130B1000 MCT-10 VLT Software, MCT 10 set-up (1 Copy) $ B1001 MCT-10 MCT 10 set-up - PC software 5 licences $1, B1002 MCT-10 MCT 10 set-up - PC software 10 licences $2, B1003 MCT-10 MCT 10 set-up - PC software 25 licences $5, B1004 MCT-10 MCT 10 set-up - PC software 50 licences $9, B1005 MCT-10 MCT 10 set-up - PC software 100 licences $16, B1006 MCT-10 MCT 10 set-up - PC software >100 licences $22, VLT Misc Accessories Order Number Description List Price 175Z0967 VLT dialog 5/6000/2800, comm, v3.0 $ Z0850 Remote LCP Kit,IP20, N1 $ N0160 LCP Remote Kit - FCM 300 series $ N0131 LCP Control Unit - VLT 2800 $ N0162 LCP Cable FCM 300 $ N0128 FCM - Motor Remote $ Z0929 Remote LCP Cable, 3m $ N3113 Cable for DeviceNet,5 Pole Conn $ B1107 LCP Graphical Control Panel $ B1124 LCP Numberical Control Panel $ B1158 LCP (For Electronic Bypass Only) $ B1117 LCP Remote Mounting Kit $90 176F1827 Pedestal Base 8 High for D frame Drives $1240 Common Mode Filters VLT Frame Core dimension [in] Weight Packaging Order Size W w H h d (lbs) Dimensions (in) Number List Price A and B x 3.94 x B3257 $110 C x 3.94 x B3258 $460 D x 7.48 x B3259 $1,125 E and F x x B3260 $1,825 Cable Length A-and B Frame C frame D frame E-F frame ft (m) T5 T7 T5 T7 T5 T7 T5 T7 165ft (50) ft (100) ft (150) ft (300) Common Mode Filters come 2 to a package. 06/01/12 II-15

54 MCD 200 Soft Starter How to Order: Choose the Normal or Heavy Duty Rating that is best suited to the application and find the Continuous Amp value that is greater than or equal to the motor s nameplate value. Order Example: MCD [1] Series 201 Soft Start without motor protection 202 Soft Start with motor protection [2] HP Rating HP HP HP HP HP HP [1] [2] [3] [4] T6 - CV HP HP HP HP [3] Supply Voltage T4 200 ~ 440 (+10% / - 15%) T6 200 ~ 575 (+10% / - 15%) [4] Control Supply CV1 24 VAC/VDC CV3 110/240 VAC; 380/440 VAC 201 T6 ( VAC) MCD 201 without motor protection HP Rating Current Rating T6 ( VAC) Typecode Enclosure 208V* 230V* 480V* 575V* Normal Heavy Order Number List MCD T6-CV3 IP G5187 $585 MCD T6-CV3 IP /10 7.5/ G5188 $695 MCD T6-CV3 IP G5189 $730 MCD T6-CV3 IP G5190 $835 MCD T6-CV3 IP G5191 $920 MCD T6-CV3 IP G5192 $975 MCD T6-CV3 IP G5193 $1,165 MCD T6-CV3 IP G5194 $1,330 MCD T6-CV3 IP 00 40/ G5195 $1,610 MCD T6-CV3 IP G5196 $2,050 MCD T6-CV3 IP G5197 $2,299 MCD 201 without motor protection HP Rating Current Rating T6 ( VAC) Typecode Enclosure 208V* 230V* 480V* 575V* Normal Heavy Order Number List MCD T6-CV1 IP G5198 $585 MCD T6-CV1 IP /10 7.5/ G5199 $695 MCD T6-CV1 IP G5200 $730 MCD T6-CV1 IP G5201 $835 MCD T6-CV1 IP G5202 $920 MCD T6-CV1 IP G5203 $975 MCD T6-CV1 IP G5204 $1,165 MCD T6-CV1 IP G5205 $1,330 MCD T6-CV1 IP 00 40/ G5206 $1,610 MCD T6-CV1 IP G5207 $2,050 MCD T6-CV1 IP G5208 $2,299 06/01/12 II-17

55 MCD 200 Soft Starter 201 T4 ( VAC) MCD 201 without motor protection HP Rating Current Rating T4 ( VAC) Typecode Enclosure 208V* 230V* 480V* 575V* Normal Heavy Order Number List MCD T4-CV1 IP G5176 $540 MCD T4-CV1 IP /10 7.5/ G5177 $640 MCD T4-CV1 IP G5178 $670 MCD T4-CV1 IP G5179 $770 MCD T4-CV1 IP G5180 $850 MCD T4-CV1 IP G5181 $900 MCD T4-CV1 IP G5182 $1,070 MCD T4-CV1 IP G5183 $1,225 MCD T4-CV1 IP 00 40/ G5184 $1,535 MCD T4-CV1 IP G5185 $1,890 MCD T4-CV1 IP G5186 $2,120 MCD 201 without motor protection HP Rating Current Rating T4 ( VAC) Typecode Enclosure 208V* 230V* 480V* 575V* Normal Heavy Order Number List MCD T4-CV3 IP G5165 $540 MCD T4-CV3 IP /10 7.5/ G5166 $640 MCD T4-CV3 IP G5167 $670 MCD T4-CV3 IP G5168 $770 MCD T4-CV3 IP G5169 $850 MCD T4-CV3 IP G5170 $900 MCD T4-CV3 IP G5171 $1,070 MCD T4-CV3 IP G5172 $1,225 MCD T4-CV3 IP 00 40/ G5173 $1,535 MCD T4-CV3 IP G5174 $1,890 MCD T4-CV3 IP G5175 $2, T6 ( VAC) MCD 202 with motor protection HP Rating Current Rating T6 ( VAC) Catalog Number Enclosure 208V* 230V* 480V* 575V* Normal Heavy Order Number List MCD T6-CV3 IP G5231 $765 MCD T6-CV3 IP /10 7.5/ G5232 $900 MCD T6-CV3 IP G5233 $935 MCD T6-CV3 IP G5234 $1,095 MCD T6-CV3 IP G5235 $1,195 MCD T6-CV3 IP G5236 $1,240 MCD T6-CV3 IP G5237 $1,470 MCD T6-CV3 IP G5238 $1,665 MCD T6-CV3 IP 00 40/ G5239 $1,930 MCD T6-CV3 IP G5240 $2,300 MCD T6-CV3 IP G5241 $2,585 MCD 202 with motor protection HP Rating Current Rating T6 ( VAC) Catalog Number Enclosure 208V* 230V* 480V* 575V* Normal Heavy Order Number List MCD T6-CV1 IP G5242 $765 MCD T6-CV1 IP /10 7.5/ G5243 $900 MCD T6-CV1 IP G5244 $935 MCD T6-CV1 IP G5245 $1,095 MCD T6-CV1 IP G5246 $1,195 MCD T6-CV1 IP G5247 $1,240 MCD T6-CV1 IP G5248 $1,470 MCD T6-CV1 IP G5249 $1,665 MCD T6-CV1 IP 00 40/ G5250 $1,930 MCD T6-CV1 IP G5251 $2,300 MCD T6-CV1 IP G5252 $2,585 II-18 06/01/12

56 MCD 200 Soft Starter 202 T4 ( VAC) MCD 202 with motor protection HP Rating Current Rating T4 ( VAC) Typecode Enclosure 208V* 230V* 480V* 575V* Normal Heavy Order Number List MCD T4-CV3 IP G5209 $705 MCD T4-CV3 IP /10 7.5/ G5210 $830 MCD T4-CV3 IP G5211 $865 MCD T4-CV3 IP G5212 $1,010 MCD T4-CV3 IP G5213 $1,100 MCD T4-CV3 IP G5214 $1,170 MCD T4-CV3 IP G5215 $1,355 MCD T4-CV3 IP G5216 $1,575 MCD T4-CV3 IP 00 40/ G5217 $1,845 MCD T4-CV3 IP G5218 $2,250 MCD T4-CV3 IP G5219 $2,535 MCD 202 with motor protection HP Rating Current Rating T4 ( VAC) Typecode Enclosure 208V* 230V* 480V* 575V* Normal Heavy Order Number List MCD T4-CV1 IP G5220 $705 MCD T4-CV1 IP /10 7.5/ G5221 $830 MCD T4-CV1 IP G5222 $865 MCD T4-CV1 IP G5223 $1,010 MCD T4-CV1 IP G5224 $1,100 MCD T4-CV1 IP G5225 $1,170 MCD T4-CV1 IP G5226 $1,355 MCD T4-CV1 IP G5227 $1,575 MCD T4-CV1 IP 00 40/ G5228 $1,845 MCD T4-CV1 IP G5229 $2,250 MCD T4-CV1 IP G5230 $2,535 Normal rating is 40 degree C ambient, 3000 ft, 6 seconds ramp time, 400% Heavy rating is 40 degree C ambient, 3000 ft, 20 seconds ramp time, 400% * HP ratings are for normal rating ModBus Module 175G9000 $215 ProfiBus Module 175G9001 $300 DeviceNet Module 175G9002 $265 Remote Keypad 175G9004 $265 Finger Guard Kit 175G9007 $195 Remote Operator only 175G3061 $175 06/01/12 II-19

57 MCD 500 Soft Starter VLT Soft Starter MCD 500 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. AAC, the Adaptive Acceleration Control, automatically employs the best starting and stopping profile for the application. Adaptive Acceleration Control means that for each start and stop, the soft starter compares and adapts the process to the chosen profile best suited to the application. The VLT Soft Starter MCD 500 has a fourline graphical display and a logic keypad making programming easy. Advanced setup is possible displaying operational status. How to Order: Choose the Normal or Heavy Duty Rating that is best suited to the application. Find the Continuous Amp value that is greater than or equal to the motor s nameplate value. Order Example: [1] [2] [3] [4] [5] [6] [7] MCD B - T5 - G1 - X CV2 [1] Amperage rating [5] Reserved ( HP) X = Not used [2] Bypass Rating [6] IP Rating B = Bypassed ( amp only) 00 = IP 00 C = Non-Bypassed 20 = IP 20 [3] Mains Voltage [7] Control Voltage T5 = VAC CV1 = 24 VAC / VDC T7 = VAC CV2 = VAC OR [4] Frame Size VAC G1 = 21 ~105 amps G2 = 131 ~ 215 amps G3 = 245 amps G4 = 360 ~ 927 amps G5 = 1200 ~ 1600 amps II-20 06/01/12

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 INTRODUCTION The Aquavar Intelligent Pump Controller from utilizes an all new Aquavar platform, and combines it with over 20 years of

More information

ROBICON W120 enclosed drive

ROBICON W120 enclosed drive SINAMICS Drives ROBICON W120 enclosed drive 1 HP to 200 HP Introduction This technical data sheet provides a short overview of the most important characteristics of the ROBICON W120 enclosed standard 6-pulse

More information

Standard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

AuCom - Soft Starters

AuCom - Soft Starters AuCom - Soft Starters AuCom - Soft Starters 208 CSXi Compact Soft Starters AuCom s new CSX Series includes two ranges. Users can choose between a simple soft start control device and an advanced soft start

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

Sensorless Vector Drives

Sensorless Vector Drives STANDARD PRODUCTS Sensorless Vector Drives SG SERIES STANDARD DUTY / HEAVY DUTY RATINGS Variable Torque: 7.5 to 700HP @ 460V 7.5 to 40HP @ 2V Standard Duty: 7.5 to 600HP @ 460V 7.5 to 40HP @ 2V Heavy Duty:

More information

RVS-DX Digital Reduced Voltage Motor Starter

RVS-DX Digital Reduced Voltage Motor Starter RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

ADJUSTABLE FREQUENCY CRANE CONTROLS

ADJUSTABLE FREQUENCY CRANE CONTROLS IMPULSE G+ MINI ADJUSTABLE FREQUENCY CRANE CONTROLS The IMPULSEG+ Mini from Magnetek continues our history of providing the most reliable and cost-effective adjustable frequency crane controls available.

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications The Reliance Electric LiquiFlo AC drive combines high-performance variable speed drive technology with a patented liquid-cooling

More information

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC

More information

MCD 200 Series Soft Starters

MCD 200 Series Soft Starters MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When

More information

Marine Annex covering all VLT Drives Note

Marine Annex covering all VLT Drives Note Marine Annex covering all VLT Drives Note Document ID: 00735874 Rev., Sequence: A,1 Project/ Activity: File Origin Date: File Last Modified Creator: P400 - Platform 2017-03-28 2017-03-28 Jacobsen, Carsten

More information

Buildings. Product Name. THE SMART CHOICE FOR ENERGY SAVINGS. SmartVFD HVAC and BYPASS

Buildings. Product Name. THE SMART CHOICE FOR ENERGY SAVINGS. SmartVFD HVAC and BYPASS Buildings Product Name THE SMART CHOICE FOR ENERGY SAVINGS. SmartVFD HVAC and BYPASS SMARTVFD HVAC AND BYPASS Saving Energy the Smart Way Buildings consume more than 70 percent of the electricity produced

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

98% Energy efficiency

98% Energy efficiency Selection Guide VLT High Power Drives that fit your application 98% Energy efficiency Save energy and money with >98% efficient VLT drives. www.danfoss.com/drives 2 Contents Designed to be easy to own

More information

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters Motors Automation Energy Transmission & Distribution Coatings GPH2 Combination Soft Starters GPH2 Combination Soft Starter 5to 350 HP The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general

More information

BAC Custom Engineered Controls

BAC Custom Engineered Controls BAC Custom Engineered Controls Product Detail Product Introduction......................................... K2 BAC Custom Engineered Controls Benefits....................................................

More information

Features and Benefits. Control Features

Features and Benefits. Control Features Features and Benefits AC induction motors have become increasingly dominant in industrial facilities worldwide. Manufacturers faced with increasing pressure to control costs have recognized that motor

More information

HVW701 HVAC Drive with By-Pass

HVW701 HVAC Drive with By-Pass s Automation Energy Transmission & Distribution Coatings HVW701 HVAC with By-Pass Designed Especially for HVAC Systems US.HVW701.By-Pass.07/2017 www.weg.net WEG HVAC-R Products WEG, a leading supplier

More information

SP600 AC Drives MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3)

SP600 AC Drives MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3) MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3) SP Models: (4) Analog Input #1 (0-10 VDC or 4-20 ma) Analog Output (0-10 VDC) Refer to the Standard Motors and Drives Catalog for Standard features

More information

98% VLT High Power Drives to fit your application. energy efficiency. drives.danfoss.com. Selection Guide

98% VLT High Power Drives to fit your application. energy efficiency. drives.danfoss.com. Selection Guide Selection Guide VLT High Power Drives to fit your application 98% energy efficiency Save energy and money with >98% efficient VLT drives drives.danfoss.com 2 Contents Easy-to-own AC drives with application-specific

More information

Delta Products VFD CP2000 Bypass Control Packages.

Delta Products VFD CP2000 Bypass Control Packages. Delta Products VFD CP2000 Bypass Control Packages www.deltaww.com Delta Products VFD CP2000 Bypass Control Packages The Delta Products VFD CP2000 Bypass Control Packages are designed for the Delta Products

More information

High performance Vector Control. Ratings. System configuration

High performance Vector Control. Ratings. System configuration System configuration High performance Vector Control Low harmonic or regenerative drive IP54 full range Compact design and robustness Built-in filter (according to C3 class) Built-in fuses (from 200 kw)

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal

More information

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3 Type number key VFD 007 CP 43 Option cards A B C S -XY Y=0: UL open 1: NEMA1 X=0: IP00 2: IP20 Version number: A=Wall mount B=Higher rated current C=Cabinet S=Frame D0 Input voltage 23=230VAC 3φ 43=400VAC

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP Phoenix DX Sensorless AC Vector Drive 3 HP to 3500 HP Standard Features: * PRECISE CONTROL OF MOTOR SPEED AND TORQUE * BI-DIRECTIONAL FLYCATCHER (CATCH SPINNING MOTOR) * EASY TO USE, SIMPLE SETUP * POWER

More information

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA SmartVFD HVAC APPLICATION The SmartVFD HVAC is a variable frequency drive designed for use in HVAC application to control the speed of HVAC pumps and fans in order to maximize energy efficiency. Smart

More information

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS The Thyro-PX series are modular, easy-to-use premier performance SCR power controllers for heating elements, resistive loads and transformer loads,

More information

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Selection Checklist CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Use this checklist to help you configure your CENTERLINE 2500 Motor Control Center. You can type in the fields

More information

VS1PFB 230V, 50/60 Hz, 3-Phase

VS1PFB 230V, 50/60 Hz, 3-Phase Farm Duty Unit Handling Brake 200 & 575 Volt Pump and Fan Bypass AC Drive 7.5 thru 40 Hp 7.5 thru 125 Hp & Controls 230 VAC 460 VAC 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications: Pump and Fan AC Drive

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides

More information

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

A. Danfoss VLT Soft Starter The single speed drive.  For any soft start situation MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Danfoss VLT Soft Starter The single speed drive 3 1600 A For any soft start situation VLT Soft Starters cover the full range from simple start-stop operation to high end performance.

More information

3 Internal Frequency Converter Operation 43

3 Internal Frequency Converter Operation 43 High Power Service Manual for VLT FC Series Contents Contents 1 Introduction 11 Purpose 11 VLT FC Product Overview 11 For Your Safety 11 Electrostatic Discharge (ESD) 12 Frame Size Definitions 12 Tools

More information

Motors Automation Energy Transmission & Distribution Coatings UBW. Molded-Case Circuit Breaker UL 489 Listed

Motors Automation Energy Transmission & Distribution Coatings UBW. Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed USA..07/2017 Molded-Case Circuit Breaker UL 489 Listed The WEG Series of Molded Case Circuit Breakers

More information

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the

More information

CTi Automation - Phone: Fax: Web:

CTi Automation - Phone: Fax: Web: CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net The control & protection you expect in an innovative soft starter design... Flexibility

More information

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Softstarters. Softstarters Type SSM Medium voltage ,800V 1 Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum

More information

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9. SED2 with Conventional Bypass Options Important Note: VD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies

More information

Reduced Voltage Starters

Reduced Voltage Starters Reduced Voltage Starters Reduced Voltage Starters- ASTAT XT Soft Starter Description and Features...2-2 Product Number Configuration...2-3 NEMA and IEC Ratings...2-4 Technical Specifications...2-5 Functions...2-6

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives REGAL-BELOIT SpinMaster Volts/Hertz Constant Torque, Micro Inverter Applications: Constant torque or constant horsepower applications. Typical applications include conveyors, packaging machinery, machine

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

BR Second Position Voltages. AA Fourth Position

BR Second Position Voltages. AA Fourth Position 1336S First Position Bulletin Number BR Second Position Voltage Letter AQ BR CW A B BP BX C Q R RX W Voltages 200-240V AC or 3V DC 380-480VAC or 513-620V DC 500-600V AC or 775V DC or 200-240V AC 380-480V

More information

Instruction Manual. VLT AutomationDrive FC 300

Instruction Manual. VLT AutomationDrive FC 300 Instruction VLT AutomationDrive FC 300 Contents Contents 1. How to Read this Instruction 3 Approvals 4 Symbols 4 Abbreviations 5 2. Safety Instructions and General Warning 7 High Voltage 8 Avoid Unintended

More information

HVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars

HVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars HVAC Drives Lenze AC Tech MCH Series Price Book May 2015 - US Dollars Document: pcmchusd-0515_a MCH Series Drives: Model Number Designation Code The MCH Series drives are rated for variable torque applications,

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for

More information

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE Danfoss VLT Soft Starter The single speed drive 3 1600 A For any soft start situation VLT Soft Starters cover the full range from simple startstop operation to high end performance.

More information

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the

More information

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran 4 Project:_ Engineer:_ Mitsubishi Electric Automation, Inc. (MEAU) Variable Frequency Drives - HVAC System Submittal Summary Data Form NEMA 1 Bypass Systems Architect:_ Contractor:_ Submitted by: Date:

More information

HVAC-R Drive Products

HVAC-R Drive Products Motors Automation Energy Transmission & Distribution Coatings HVAC-R Drive Products Designed Especially for HVAC Systems US.HVAC-R Drive.Products.01/2017 www.weg.net/us WEG HVAC-R Products WEG, a leading

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

MCD Pump Application Module

MCD Pump Application Module Overview The Pump Application Module expands the soft starter's input and output functionality and is ideal for applications where greater control and feedback are required. The module provides three digital

More information

Product Brochure. The motor speed control experts. AC motor speed control products and peripherals for the motion and automation control industries

Product Brochure. The motor speed control experts. AC motor speed control products and peripherals for the motion and automation control industries Product Brochure AC motor speed control products and peripherals for the motion and automation control industries The motor speed control experts www.motorcontrolwarehouse.co.uk Rev 1 The Motor Control

More information

98% VLT High Power Drives that fit your application. Selection Guide. Energy efficiency MAKING MODERN LIVING POSSIBLE

98% VLT High Power Drives that fit your application. Selection Guide.   Energy efficiency MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Selection Guide VLT High Power Drives that fit your application 98% Energy efficiency Save energy and money with >98% efficient VLT drives www.danfoss.com/drives 2 Contents

More information

GPH2 Combination Soft Starters

GPH2 Combination Soft Starters Combination Soft Starters The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general purpose AC motor soft starter package. It is designed for simple and quick installation and start-up, requiring

More information

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x. Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,

More information

CUSTOMIZED OPTIONS FOR 1-WEEK DELIVERY

CUSTOMIZED OPTIONS FOR 1-WEEK DELIVERY IN STOCK GUARANTEED! Benshaw is offering the most Rugged, Reliable and Proven soft starter for your most demanding and tough applications CUSTOMIZED OPTIONS FOR 1-WEEK DELIVERY A Regal Brand 2017 Information

More information

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK PART 1 - GENERAL 1.1 GENERAL: SECTION 15150 MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK A. The Mechanical Contractor shall furnish to the Electrical Contractor for installation,

More information

Operating Instructions VLT Soft Starter MCD 500

Operating Instructions VLT Soft Starter MCD 500 MAKING MODERN LIVING POSSIBLE Operating Instructions VLT Soft Starter MCD 500 vlt-drives.danfoss.com Contents Operating Instructions Contents 1 Safety 6 1.1 Warnings 6 2 Introduction 8 3 Installation

More information

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature

More information

ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS

ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS (Disconnect and Bypass Packages are available on Pages 56 and 57) Two Year Warranty* *When Gerrie commissions the drive Features: UL/cUL/CSA Approved

More information

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive Installation Guide VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive FC 301/FC 302 Installation Guide VLT Real-time Clock MCB

More information

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company Manufacturer of Dimensions Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL April

More information

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000 VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000 Soft starts Protect Gear, Goods, Equipment and Environment An AC motor switched directly on to the mains power supply will struggle to reach its nominal

More information

825-P Modular Protection System for motors Specification Guide

825-P Modular Protection System for motors Specification Guide Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection

More information

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Application example of a motor controlled by MCD100 and protected by a circuit breaker VLT T Soft Start Controller MCD 100 MCD 100 is a cost effective and extremely compact soft starter for AC motors up to 11 kw. Due to a unique semiconductor design MCD 100 is a true fit and forget product.

More information

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein. DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings

More information

2 Safety Instructions and General Warning 2-1

2 Safety Instructions and General Warning 2-1 VLT AutomationDrive FC 300 Instruction Contents Contents 1 How to Read this Instruction 1-1 Approvals 1-2 Symbols 1-2 Abbreviations 1-3 2 Safety Instructions and General Warning 2-1 High Voltage 2-1 Safe

More information

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications Contents Selection................ Product Selection....................... Accessories........................... Technical Data and Specifications.......... Dimensions........................... Page

More information

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass SED2 VD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass Description The NEMA Type 3R Bypasses are companion packages for the family of SED2 Variable requency Drives (VD). NEMA Type 3R/3RHE enclosed

More information

1.1 Caution Statements

1.1 Caution Statements USER MANUAL 1.1 Caution Statements Caution Statements cannot cover every potential cause of equipment damage but can highlight common causes of damage. It is the installer's responsibility to read and

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Unidrive M700 Class leading performance with onboard real-time Ethernet

Unidrive M700 Class leading performance with onboard real-time Ethernet Unidrive M Class leading performance with onboard real-time Ethernet. kw -.8 MW Heavy Duty (. hp -, hp) V V V 9 V Unidrive M features Easy click-in keypad connection Range of multi-language LCD keypads

More information

NEW! Complete IMPULSE Control Panels Available

NEW! Complete IMPULSE Control Panels Available TELEMOTIVE ENRANGE MONDEL Complete IMPULSE Control Panels Available YOUR ONE-STOP SOURCE FOR MATERIAL HANDLING CONTROL SOLUTIONS Electromotive Systems IMPULSEG+ Mini STANDARD FEATURES INCLUDE: 120 Volt

More information

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10 Contents Contents 1 Warnings 3 2 Troubleshooting 5 Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10 3 Service Instructions 13 Frame

More information

Electromotive Systems IMPULSE G+ Mini Adjustable Frequency Crane Controls

Electromotive Systems IMPULSE G+ Mini Adjustable Frequency Crane Controls Electromotive Systems IMPULSE G+ Mini Adjustable Frequency Crane Controls ELECTROMOTIVE SYSTEMS Introducing IMPULSE G+ Mini Adjustable Frequency Crane Controls The new IMPULSEG+ Mini from Magnetek continues

More information

Operating Guide. VLT Soft Starter MCD 600

Operating Guide. VLT Soft Starter MCD 600 Operating Guide VLT Soft Starter MCD 600 Contents Contents 1 Introduction 8 1.1 Product Description 8 1.2 Document Version 8 1.3 Additional Resources 8 1.4 Approvals and Certifications 8 2 Safety 9 2.1

More information

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Product Description The SED2 Conventional Bypass (C-Bypass) Options are companion packages for the family of SED2 Variable Frequency

More information

Drives. Section Rev. 7/13. Prices and data subject to change without notice

Drives. Section Rev. 7/13. Prices and data subject to change without notice AF-60LP Micro Drive Product Description...15-2 Product Number System Diagram...15-2 Pricing, Dimensions and Weights...15-3 Options, Accessories, and Replacement Parts...15-4 Dynamic Braking Resistors...15-5

More information

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD Safety Precautions Read this manual thoroughly before proceeding with installation, connections (wiring), or maintenance and inspection. Ensure you

More information

ABB standard drives ACS550, Hp

ABB standard drives ACS550, Hp ABB standard drives ACS550, 0.75-550 Hp Technical catalog BUSINESS PROFILE INDUSTRIES PRODUCTS APPLICATIONS EXPERTISE PARTNERS SERVICES Two ways to select your drive Choice 1: Simply contact your local

More information

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M600 features Easy click-in keypad

More information

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass APC Smart-UPS VT, 24 kw / 30 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com ISO 9001:2000 Certified

More information

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives Technical catalog 0.75 to 75 HP @ 240 Vac 2 to 2250 HP @ 480 Vac 5 to 3000 HP @ 600 Vac BUSINESS

More information

Phone: Fax: Web:

Phone: Fax: Web: Description Wide rated operational voltage 208 690 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 30 to 1050 A (Up to 1810 A inside delta) Wide ambient temperature

More information

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs 0.25 kw - 110 kw (0.33 hp - 150 hp) 100 V 200 V 400 V 575 V 690 V Unidrive M400 features Optional AI-485

More information

L300P Inverter Specifications

L300P Inverter Specifications L300P Inverter Specifications Tables for 200V class inverters Note that General Specifications on page 1 9 covers all L300P inverters, followed by footnotes for all specifications tables. Seven 200V models

More information

DC to AC Power Inverters

DC to AC Power Inverters Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121114C OWNERS

More information

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives Technical catalog 0.75 to 75 HP @ 240 Vac 2 to 2250 HP @ 480 Vac 5 to 3000 HP @ 600 Vac BUSINESS

More information

ABB industrial drives ACS800, drive modules. 2 to Vac 5 to Vac

ABB industrial drives ACS800, drive modules. 2 to Vac 5 to Vac ABB industrial drives ACS800, drive modules Technical catalog 0.75 to 250 HP @ 240 Vac 2 to 2800 HP @ 480 Vac 5 to 2400 HP @ 600 Vac Contents ABB industrial drives 1 2 3 4 Product series Drive Modules

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW Medium Voltage Product Overview MVB SERIES, MEDIUM VOLTAGE DRAW-OUT CIRCUIT BREAKER MVB SERIES Standard Breaker Features : 1200, 2000, 3000 Amps, 3 phase, 60

More information

GS2 Series - Introduction

GS2 Series - Introduction GS2 Series - Introduction GS2 Series Drives Rating Hp.25.5 1 2 3 5 7.5 10 kw 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 Single-Phase 115 Volt Class Single/Three-Phase 230 Volt Class Three-Phase 230 Volt Class Three-Phase

More information