Multi V Air Conditioner SVC MANUAL(Exploded View)
|
|
- Kristina Payne
- 6 years ago
- Views:
Transcription
1 Internal Use Only Multi V Air Conditioner SVC MANUAL(Exploded View) MODEL : ARNU073BGA4 ARNU093BGA4 ARNU123BGA4 ARNU153BGA4 ARNU183BGA4 ARNU243BGA4 ARNU283BGA4 ARNU363BGA4 ARNU423BGA4 ARNU283BRA4 ARNU363BRA4 ARNU423BRA4 ARNU483BRA4 ARNU543BRA4 ARNU363B8A4 ARNU423B8A4 ARNU483B8A4 ARNU763B8A4 ARNU963B8A4 ARNU073BHA4 ARNU093BHA4 ARNU123BHA4 ARNU153BHA4 ARNU183BHA4 ARNU243BHA4 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
2 1. Specification Cooling Capacity Heating Capacity Casing Model Unit Dimensions(WxDxH) mm Body inch Coil Rows x Columns x FPI Face Area m 2 (ft 2 ) Motor Output x Number W Running Current A (High Modefactory set) cfm Fan (Standard Mode) cfm Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side mm(inch) Pipe Connections Gas Side mm(inch) Drain Pipe(Internal Dia.) mm(inch) Net Weight Body kg(lbs) Noise Level(Sound Press, 1.5m(4.9ft) H/M/L) db(a) + 1 Power Supply Ø, V, Hz Refrigerant Control Power cable mm 2 Transmission Cable (AWG#C) mm 2 ARNU073BHA ,900 7, ,200 8, x 260 x /32 x 101/4 x 1723/32 2 x 10 x / 5.8 / / 205 / 191 8(78) 7.3 / 6.3 / / 222 / 198 6(59) Ø6.35(1/4) Ø12.7(1/2) 26(57.4) 34 / 33 / 32 CVVSB 1.0~1.5 x 2C Ceiling Concealed Duct(High Static) ARNU093BHA ,400 9, ,800 10, x 260 x /32 x 101/4 x 1723/32 2 x 10 x / 6.5 / / 230 / 205 8(78) 7.3 / 6.3 / / 222 / 198 6(59) Ø6.35(1/4) Ø12.7(1/2) 26(57.4) 36 / 35 / 33 CVVSB 1.0~1.5 x 2C ARNU123BHA ,100 12, ,400 13, x 260 x /32 x 101/4 x 1723/32 2 x 10 x / 8.1 / / 286 / 230 8(78) 8.7 / 7.3 / / 258 / 198 6(59) Ø6.35(1/4) Ø12.7(1/2) 26(57.4) 37 / 35 / 34 CVVSB 1.0~1.5 x 2C Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB Outdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB Outdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 2
3 Cooling Capacity Heating Capacity Casing Model Unit Dimensions(WxDxH) mm Body inch Coil Rows x Columns x FPI Face Area m 2 (ft 2 ) Motor Output x Number W Running Current A (High Modefactory set) cfm Fan (Standard Mode) cfm Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side mm(inch) Pipe Connections Gas Side mm(inch) Drain Pipe(Internal Dia.) mm(inch) Net Weight Body kg(lbs) Noise Level(Sound Press, 1.5m(4.9ft) H/M/L) db(a) + 1 Power Supply Ø, V, Hz Refrigerant Control Power cable mm 2 Transmission Cable (AWG#C) mm 2 ARNU153BHA ,900 15, ,300 17, x 260 x /32 x 101/4 x 1723/32 2 x 10 x / 9.6 / / 339 / 230 8(78) 11.0 / 10.1 / / 357 / 307 6(59) Ø6.35(1/4) Ø12.7(1/2) 26(57.4) 39 / 37 / 34 CVVSB 1.0~1.5 x 2C Ceiling Concealed Duct(High Static) ARNU183BHA ,800 19, ,400 21, x 260 x /32 x 101/4 x 1723/32 3 x 10 x / 11.3 / / 399 / 339 8(78) 13.2 / 11.7 / / 413 / 258 6(59) Ø6.35(1/4) Ø12.7(1/2) 26.5(58.4) 40 / 38 / 37 CVVSB 1.0~1.5 x 2C ARNU243BHA ,100 24, ,900 27, x 260 x /32 x 101/4 x 1723/32 3 x 10 x / 14.4 / / 509 / 459 8(78) 17.5 / 14.7 / / 519 / 445 6(59) Ø15.88(5/8) 26.5(58.4) 42 / 41 / 40 CVVSB 1.0~1.5 x 2C Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB Outdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB Outdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 3
4 Cooling Capacity Heating Capacity Casing Model Unit Dimensions(WxDxH) mm Body inch Coil Rows x Columns x FPI Face Area m 2 (ft 2 ) Motor Output x Number W Running Current A (High Modefactory set) cfm Fan (Standard Mode) cfm Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side mm(inch) Pipe Connections Gas Side mm(inch) Drain Pipe(Internal Dia.) mm(inch) Net Weight Body kg(lbs) Noise Level(Sound Press, 1.5m(4.9ft) H/M/L) db(a) + 1 Power Supply Ø, V, Hz Refrigerant Control Power cable mm 2 Transmission Cable (AWG#C) mm 2 ARNU073BGA ,900 7, ,200 8,500 1,182 x 298 x /32 x 1123/32 x 1723/32 3 x 12 x (2.82) / 11.5 / / 406 / 332 6(0.23) 14.6 / 13.7 / / 484 / 434 4(0.15) Ø15.88(5/8) 38(83.8) 35 / 35 / 34 CVVSB 1.0~1.5 x 2C (122) Ceiling Concealed Duct(High Static) ARNU093BGA ,400 9, ,800 10,900 1,182 x 298 x /32 x 1123/32 x 1723/32 3 x 12 x (2.82) / 11.5 / / 406 / 332 6(0.23) 15.1 / 13.7 / / 484 / 434 4(0.15) Ø15.88(5/8) 38(83.8) 35 / 35 / 34 CVVSB 1.0~1.5 x 2C (122) ARNU123BGA ,100 12, ,400 13,600 1,182 x 298 x /32 x 1123/32 x 1723/32 3 x 12 x (2.82) / 12.1 / / 427 / 332 6(0.23) 16.6 / 15.1 / / 533 / 484 4(0.15) Ø15.88(5/8) 38(83.8) 36 / 35 / 34 CVVSB 1.0~1.5 x 2C (122) Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB Outdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB Outdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 4
5 Cooling Capacity Heating Capacity Casing Model Unit Dimensions(WxDxH) mm Body inch Coil Rows x Columns x FPI Face Area m 2 (ft 2 ) Motor Output x Number W Running Current A (High Modefactory set) cfm Fan (Standard Mode) cfm Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side mm(inch) Pipe Connections Gas Side mm(inch) Drain Pipe(Internal Dia.) mm(inch) Net Weight Body kg(lbs) Noise Level(Sound Press, 1.5m(4.9ft) H/M/L) db(a) + 1 Power Supply Ø, V, Hz Refrigerant Control Power cable mm 2 Transmission Cable (AWG#C) mm 2 ARNU153BGA ,900 15, ,300 17,100 1,182 x 298 x /32 x 1123/32 x 1723/32 3 x 12 x (2.82) / 11.8 / / 417 / 293 8(0.31) 13.5 / 12.1 / / 427 / 318 6(0.23) Ø15.88(5/8) 38(83.8) 35 / 35 / 34 CVVSB 1.0~1.5 x 2C (122) Ceiling Concealed Duct(High Static) ARNU183BGA ,800 19, ,400 21,500 1,182 x 298 x /32 x 1123/32 x 1723/32 3 x 12 x (2.82) / 13.8 / / 487 / 417 8(0.31) 15.5 / 13.3 / / 470 / 427 6(0.23) Ø15.88(5/8) 38(83.8) 35 / 35 / 34 CVVSB 1.0~1.5 x 2C (122) ARNU243BGA ,100 24, ,900 27,300 1,182 x 298 x /32 x 1123/32 x 1723/32 3 x 12 x (2.82) / 15.2 / / 537 / 487 8(0.31) 19.0 / 16.3 / / 576 / 547 6(0.23) Ø15.88(5/8) 38(83.8) 36 / 35 / 34 CVVSB 1.0~1.5 x 2C (122) Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB Outdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB Outdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 5
6 Cooling Capacity Heating Capacity Casing Model Unit Dimensions(WxDxH) mm Body inch Coil Rows x Columns x FPI Face Area m 2 (ft 2 ) Motor Output x Number W Running Current A (High Modefactory set) cfm Fan (Standard Mode) cfm Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side mm(inch) Pipe Connections Gas Side mm(inch) Drain Pipe(Internal Dia.) mm(inch) Net Weight Body kg(lbs) Noise Level(Sound Press, 1.5m(4.9ft) H/M/L) db(a) + 1 Power Supply Ø, V, Hz Refrigerant Control Power cable mm 2 Transmission Cable (AWG#C) mm 2 ARNU283BGA ,100 28, ,000 31,500 1,182 x 298 x /32 x 1123/32 x 1723/32 3 x 12 x (2.82) / 24.1 / / 851 / (0.39) 25.3 / 21.8 / / 770 / 622 8(0.31) Ø15.88(5/8) 38(83.8) 36 / 35 / 34 CVVSB 1.0~1.5 x 2C (122) Ceiling Concealed Duct(High Static) ARNU363BGA ,100 36, ,200 40,600 1,182 x 298 x /32 x 1123/32 x 1723/32 3 x 12 x (2.82) / 29.0 / ,141 / 1,024 / (0.39) 28.4 / 25.3 / ,003 / 894 / 770 8(0.31) Ø15.88(5/8) 38(83.8) 36 / 35 / 34 CVVSB 1.0~1.5 x 2C (122) ARNU423BGA ,600 42, ,000 43,800 1,182 x 298 x /32 x 1123/32 x 1723/32 3 x 12 x (2.82) / 32.3 / ,218 / 1,141 / 1,084 10(0.39) 32.0 / 28.4 / ,130 / 1,003 / 961 8(0.31) Ø15.88(5/8) 38(83.8) 36 / 35 / 34 CVVSB 1.0~1.5 x 2C (122) Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB Outdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB Outdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 6
7 Ceiling Concealed Duct High Static Model Unit ARNU283BRA4 ARNU363BRA4 ARNU423BRA Cooling Capacity 7,100 9,100 10,600 28,000 36,200 42, Heating Capacity 8,000 10,200 11,000 31,500 40,600 43,800 Casing Dimensions mm 1,230 x 380 x 590 1,230 x 380 x 590 1,230 x 380 x 590 Body (WxHxD) inch 487/16 x 1431/32 x 237/32 487/16 x 1431/32 x 237/32 487/16 x 1431/32 x 237/32 Coil Rows x Columns x FPI 3 x 13 x 19 3 x 13 x 19 3 x 13 x 19 Face Area m²(sq.ft) 0.38(4.12) 0.38(4.12) 0.38(4.12) Motor Output x Number W 185 x x x 2 Running Current A Air Flow Rate(H / M / L) CMM 36.2 / 32.1 / / 33.3 / / 39.1 / 33.3 (High ModeFactory Set) cfm 1,278 / 1,134 / 1,007 1,381 / 1,176 / 1,049 1,490 / 1,381 / 1,176 Fan Ext Static Pressure mmaq(in.aq) 14(140) 14(140) 14(140) Air Flow Rate(H / M / L) CMM 32.6 / 31.3 / / 32.6 / / 40.5 / 32.6 (Standard Mode) cfm 1,151 / 1,105 / 1,074 1,430 / 1,151 / 1,105 1,497 / 1,430 / 1,151 Ext Static Pressure mmaq(in.aq) 10(100) 10(100) 10(100) Drive Motor type Temperature Control for for for cooling and heating cooling and heating cooling and heating Sound Absorbing Thermal Insulation Material Air Filter Safety Device Pipe Connections Liquid Side mm(inch) Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8) Drain Pipe(Internal Dia.) mm(inch) Net Weight Body kg(lbs) 53(116.8) 53(116.8) 53(116.8) Noise Level(Sound Press, 1.5m, H / M / L) db(a) 41 / 40 / / 41 / / 42 / 41 Power Supply Ø, V, Hz Refrigerant Control Power cable mm² Transmission Cable(AWG#C) mm² CVVSB x 2C CVVSB x 2C CVVSB x 2C Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB Outdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB Outdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 7
8 Cooling Capacity Heating Capacity Casing Model Unit Dimensions(WxDxH) mm Body inch Coil Rows x Columns x FPI Face Area m 2 (ft 2 ) Motor Output x Number W Running Current A (High Modefactory set) cfm Fan (Standard Mode) cfm Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side mm(inch) Pipe Connections Gas Side mm(inch) Drain Pipe(Internal Dia.) mm(inch) Net Weight Body kg(lbs) Noise Level(Sound Press, 1.5m(4.9ft) H/M/L) db(a) + 1 Power Supply Ø, V, Hz Refrigerant Control Power cable mm 2 Transmission Cable (AWG#C) mm 2 ARNU483BRA ,100 48, ,200 51,200 1,230 x 380 x /16 x 1431/32 x 237/32 3 x 13 x (4.12) 185 x / 40.6 / ,582 / 1,434 / 1,176 14(0.55) 44.4 / 39.5 / ,568 / 1,395 / 1,183 10(0.39) Microprocessor, Thermostat Ø15.88(5/8) 53(117) 45 / 43 / 41 CVVSB 1.0~1.5 x 2C (122) Ceiling Concealed Duct(High Static) ARNU543BRA ,600 54, ,500 61,400 1,230 x 380 x /16 x 1431/32 x 237/32 3 x 13 x (4.12) 185 x / 44.8 / ,801 / 1,582 / 1,434 14(0.55) 51.5 / 47.5 / ,819 / 1,678 / 1,395 10(0.39) Microprocessor, Thermostat Ø15.88(5/8) 53(117) 46 / 45 / 43 CVVSB 1.0~1.5 x 2C (122) Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB Outdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB Outdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 8
9 Ceiling Concealed Duct(High Static) Model Unit ARNU363B8A4 ARNU423B8A4 ARNU483B8A Cooling Capacity 9,100 10,600 12,100 36,200 42,000 48, Heating Capacity 10,200 11,000 13,200 40,600 43,800 51,200 Casing Dimensions mm 1,562 x 460 x 688 1,562 x 460 x 688 1,562 x 460 x 688 Body (WxHxD) inch 611/2 x 181/8 x /2 x 181/8 x 273/32 611/2 x 181/8 x 273/32 Coil Rows x Columns x FPI 3 x 21 x 19 3 x 21 x 19 3 x 21 x 19 Face Area m²(sq.ft) Motor Output x Number W 375 x x x 2 Running Current A Air Flow Rate(H / M / L) CMM 49.0 / 37.3 / / 41.3 / / 43.0 / 34.0 (High ModeFactory Set) cfm 1,730 / 1,317 / 1,066 1,914 / 1,458 / 1,123 2,019 / 1,518 / 1,200 Fan Ext Static Pressure mmaq(in.aq) 18(180) 18(180) 18(180) Temperature Control Air Flow Rate(H / M / L) (Standard Mode) Ext Static Pressure CMM 53.7 / 49.5 / / 50.6 / / 52.3 / 47.3 cfm 1,896 / 1,748 / 1,550 1,963 / 1,786 / 1,589 2,048 / 1,846 / 1,670 mmaq(in.aq) 9(90) 9(90) 9(90) Drive Motor type for cooling and heating for cooling and heating for cooling and heating Sound Absorbing Thermal Insulation Material Air Filter Safety Device Pipe Connections Liquid Side mm(inch) Gas Side mm(inch) Ø19.05(3/4) Ø19.05(3/4) Ø19.05(3/4) Drain Pipe(Internal Dia.) mm(inch) Net Weight Body kg(lbs) 91(200) 91(200) 91(200) Noise Level(Sound Press, 1.5m, H / M / L) db(a) 46 / 45 / / 46 / / 46 / 44 Power Supply Ø, V, Hz Refrigerant Control Power cable mm² Transmission Cable(AWG#C) mm² CVVSB 1.0~1.5 x 2C CVVSB 1.0~1.5 x 2C CVVSB 1.0~1.5 x 2C Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB Outdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB Outdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 9
10 Cooling Capacity Heating Capacity Casing Model Unit Dimensions(WxDxH) mm Body inch Coil Rows x Columns x FPI Face Area m 2 (ft 2 ) Motor Output x Number W Running Current A (High Modefactory set) cfm Fan (Standard Mode) cfm Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side mm(inch) Pipe Connections Gas Side mm(inch) Drain Pipe(Internal Dia.) mm(inch) Net Weight Body kg(lbs) Noise Level(Sound Press, 1.5m(4.9ft) H/M/L) db(a) + 1 Power Supply Ø, V, Hz Refrigerant Control Power cable mm 2 Transmission Cable (AWG#C) mm 2 ARNU763B8A ,300 76, ,700 86,000 1,562 x 460 x /2 x 181/8 x 273/32 3 x 21 x (6.39) 375 x / 50.0 / ,119 / 1,766 / 1,766 22(0.87) 58.0 / 50.0 / ,260 / 1,766 / 1,766 15(0.59) Microprocessor, Thermostat Ø19.05(3/4) 91(200) 50 / 48 / 48 CVVSB 1.0~1.5 x 2C (122) Ceiling Concealed Duct(High Static) ARNU963B8A ,100 95, , ,500 1,562 x 460 x /2 x 181/8 x 273/32 3 x 21 x (6.39) 375 x / 64.0 / ,542 / 2,260 / 2,260 22(0.87) 76.0 / 64.0 / ,684 / 2,260 / 2,260 15(0.59) Microprocessor, Thermostat Ø22.2(7/8) 91(200) 52 / 50 / 50 CVVSB 1.0~1.5 x 2C (122) Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB Outdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB Outdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. : Electronic Expansion Valve 6. Noise Level is Standard Mode (for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA) Conversion Formula = x 860 = x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 10
11 2. List of Functions Category Air flow Air purifying Installation Reliability Convenience Individual control Special function kit Function Air supply outlet Airflow direction control(left & right) Airflow direction control(up & down) Auto swing(left & right) Auto swing(up & down) Airflow steps(fan/cool/heat) Chaos swing Chaos wind(auto wind) Jet cool(power wind) Swirl wind Deodorizing filter Plasma air purifier Prefilter(washable / antifungus) Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Standard wired remote controller Wide Character wired remote controller Picto wired remote controller Deluxe wired remote controller Simple wired remote controller Wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control Zone control CTIE Electro thermostat ARNU073BHA4 ARNU093BHA4 ARNU123BHA4 ARNU153BHA4 ARNU183BHA4 ARNU243BHA4 ARNU073BGA4 ARNU093BGA4 ARNU123BGA4 ARNU153BGA4 ARNU183BGA4 ARNU243BGA4 ARNU283BGA4 ARNU363BGA4 ARNU423BGA4 ARNU283BRA4 ARNU363BRA4 ARNU423BRA4 ARNU483BRA4 ARNU543BRA4 ARNU363B8A4 ARNU423B8A4 ARNU483B8A4 ARNU763B8A4 ARNU963B8A4 1 3/3/3 X X O O O X O O O O(only heat recovery) X O(only heat pump or cooling only) O O O X O O O Accessory Accessory Accessory Accessory Accessory X Accessory Accessory O : Applied X : Not applied : No relation Option : Model name & price are different according to options, and assembled in factory with main unit. Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. 11
12 3. Piping Diagrams BH/BG/BR Chassis Heat Exchanger Filter :Cooling :Heating Th3 Th2 Filter Th1 lndoor unit Refrigerant pipe connection port diameter [Unit : mm(inch)] CHASSIS MODEL GAS LIQUID ARNU073BHA4 Ø12.7(1/2) Ø6.35(1/4) ARNU093BHA4 Ø12.7(1/2) Ø6.35(1/4) BH ARNU123BHA4 Ø12.7(1/2) Ø6.35(1/4) ARNU153BHA4 Ø12.7(1/2) Ø6.35(1/4) ARNU183BHA4 Ø12.7(1/2) Ø6.35(1/4) ARNU243BHA4 Ø15.88(5/8) ARNU073BGA4 Ø15.88(5/8) ARNU093BGA4 Ø15.88(5/8) ARNU123BGA4 Ø15.88(5/8) ARNU153BGA4 Ø15.88(5/8) BG ARNU183BGA4 Ø15.88(5/8) ARNU243BGA4 Ø15.88(5/8) ARNU283BGA4 Ø15.88(5/8) ARNU363BGA4 Ø15.88(5/8) ARNU423BGA4 Ø15.88(5/8) ARNU283BRA4 Ø15.88(5/8) ARNU363BRA4 Ø15.88(5/8) BR ARNU423BRA4 Ø15.88(5/8) ARNU483BRA4 Ø15.88(5/8) ARNU543BRA4 Ø15.88(5/8) LOC. Description PCB Connector (Color) Th1 Thermistor for room air temperature CNROOM (Yellow) Th2 Thermistor for pipe in temperature CNPIPE_IN (White) Th3 Thermistor for pipe out temperature CNPIPE_OUT (Red) 12
13 B8 Chassis Th2 Th3 Heat Exchanger Th2 Filter : Heating : Cooling Check Valve Solenoid Valve Filter Indoor Unit Th1 Refrigerant pipe connection port diameter [Unit: mm(inch)] CHASSIS MODEL GAS LIQUID ARNU363B8A4 Ø19.05(3/4) ARNU423B8A4 Ø19.05(3/4) B8 ARNU483B8A4 Ø19.05(3/4) ARNU763B8A4 Ø19.05(3/4) ARNU963B8A4 Ø22.20(7/8) LOC. Description PCB Connector (Color) Th1 Thermistor for room air temperature CNROOM (Yellow) Th2 Thermistor for pipe in temperature CNPIPE_IN (White) Th3 Thermistor for pipe out temperature CNPIPE_OUT (Red) 13
14 4. Wiring Diagrams BH Chassis CN_MOTOR1 CN_DAMPER CN_ZONE CN_ CN_DDC CN_EXT CN_OPTION CN_DISPLAY CN_PTC CN_485 CN_AIRC CN_FLOAT CN_POWER CN_D_PUMP CN_REMO CN_PIPE_IN CN_WF CN_LEAK CN_ROOM CN_PIPE_OUT CN_CC CN_HUMID 14
15 BG Chassis CN_MOTOR1 CN_DAMPER CN_ZONE CN_ CN_DDC CN_EXT CN_OPTION CN_DISPLAY CN_PTC CN_485 CN_POWER CN_D_PUMP CN_REMO CN_ROOM CN_AIRC CN_WF CN_VM CN_PIPE_IN CN_PIPE_OUT CN_LEAK CN_FLOAT CN_CC CN_HUMID 15
16 BR Chassis CN_MOTOR1 CN_MOTOR2 CN_DAMPER CN_ZONE CN_EXT CN_ CN_OPTION CN_DISPLAY CN_WRITE CN_PTC CN_485 CN_POWER CN_HUMID CN_REMO CN_WF CN_CC CN_D_PUMP CN_ROOM CN_AIRC CN_LEAK CN_PIPE_IN CN_FLOAT CN_PIPE_OUT 16
17 B8 Chassis CN_MOTOR1 CN_MOTOR2 CN_DAMPER CN_ZONE CN_EXT CN_ CN_OPTION CN_DISPLAY CN_WRITE CN_PTC CN_485 CN_POWER CN_HUMID CN_REMO CN_WF CN_CC CN_D_PUMP CN_ROOM CN_AIRC CN_LEAK CN_PIPE_IN CN_FLOAT CN_PIPE_OUT 17
18 5. DIP Switch Setting 1. Indoor Unit SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Function Description Setting Off Setting On Default Communication N/A (Default) Off Cycle N/A (Default) Off Group Control Selection of Master or Slave Master Slave Off Dry Contact Mode Selection of Dry Contact Wired/Wireless remote Mode controller Selection of Manual or Auto Auto Off operation Mode Installation Heater linkage Ventilator linkage Vane selection (Console) Region selection Etc. Fan continuous operation N/A Selection of Ventilator linkage Selection of up/down side Vane Selection tropical region Spare Continuous operation Removall Linkage Removal Up side + Down side Vane General model Working Up side Vane Only Tropical model Off Off Off Off For Multi V Models, DIP switch 1, 2, 6, 8 must be set OFF. 2. Outdoor Unit In case that the products meet specific conditions, Auto addressing function can start automatically with the improved speed by turning the DIP switch #3 of the outdoor unit and resetting the power. * Specific conditions: All names of the indoor units are ARNU****4. The serial number of Multi V super IV (outdoor units) is after October DIP switch 7 segment Outdoor Unit PCB Outdoor Unit DIP Switch 18
19 6. Exploded View BH Chassis W1JK B A B A B A C THERMISTOR 2 THERMISTOR B C W3001 W W6640B A THERMISTOR D W6640A A B A B SVC No. Description Remark (Color) A Thermistor for room air temperature CNROOM (Yellow) B Thermistor for pipe in temperature CNPIPE_IN (White) C Thermistor for pipe in temperature CNPIPE_OUT (Red) A PCB for main 210 mm X 95 mm B PCB for motor 100 mm X 100 mm C PCB for option 25 mm X 25 m D PCB for communication 65 mm X 45 mm 19
20 BG Chassis A W1JK B B A B A THERMISTOR 2 THERMISTOR B C D W B E W6640B A THERMISTOR B W6640A A W W G B A SVC No. Description Remark (Color) A Thermistor for room air temperature CNROOM (Yellow) B Thermistor for pipe in temperature CNPIPE_IN (White) C Thermistor for pipe in temperature CNPIPE_OUT (Red) B PCB for communication 65 mm X 45 mm C PCB for main 210 mm X 95 mm D PCB for motor 100 mm X 100 mm E PCB for option 25 mm X 25 m 20
21 BR Chassis W1JK A A B B W6631 THERMISTOR B THERMISTOR C W A THERMISTOR B A W6640B W6640A W D B 55211G E B A SVC No. Description Remark (Color) A Thermistor for room air temperature CNROOM (Yellow) B Thermistor for pipe in temperature CNPIPE_IN (White) C Thermistor for pipe in temperature CNPIPE_OUT (Red) B PCB for communication 65 mm X 45 mm C PCB for main 210 mm X 95 mm D PCB for motor 100 mm X 100 mm E PCB for option 25 mm X 25 m 21
22 B8 Chassis B A B C A W6640B W6640C W0FZZA W0FZZB C D A B W6640A W G B A SVC No. Description Remark (Color) A Thermistor for room air temperature CNROOM (Yellow) B Thermistor for pipe in temperature CNPIPE_IN (White) C Thermistor for pipe in temperature CNPIPE_OUT (Red) A PCB for main 210 mm X 95 mm B PCB for motor 140 mm X 100 mm C PCB for option 25 mm X 25 m D PCB for communication 65 mm X 45 mm 22
23 7. Selfdiagnosis function Error Indicator This function indicates types of failure in selfdiagnosis and occurrence of failure for air condition. Error mark is displayed on display window of indoor units and wired remote controller, and 7segment LED of outdoor unit control board as shown in the table. If more than two troubles occur simultaneously, lower number of error code is first displayed. After error occurrence, if error is released, error LED is also released simultaneously. Error Display 1st,2nd,3rd LED of 7segment indicates error number, 4th LED indicates unit number. Indicates unit number. (* = 1:Master, 2 : Slave 1, 3 : Slave 2) Ex) 211 : No.21 error of master unit (repetition) 213 : No.21 error of slave : No.105 error of master unit h Refer to the DXVenitilation manual for DXVenitilation error code Error Compressor Unit(1:Master, 2:Slave 1, 3:Slave 2) Error number Display Title Cause of Error 0 1 Air temperature sensor of indoor unit Air temperature sensor of indoor unit is open or short 0 2 Inlet pipe temperature sensor of indoor unit Inlet pipe temperature sensor of indoor unit is open or short 0 3 Communication error : wired remote controller indoor unit Failing to receive wired remote controller signal in indoor unit PCB 0 4 Drain pump Malfunction of drain pump Indoor unit related error 0 5 Communication error : Indoor communication PCB indoor unit Indoor Unit PCB did not receive signal from Indoor communication PCB for over 3 minutes continuously 0 6 Outlet pipe temperature sensor of indoor unit Outlet pipe temperature sensor of indoor unit is open or short 0 9 Indoor EEPROM Error 1 0 Poor fan motor operation In case when the serial number marked on EEPROM of Indoor unit is 0 or FFFFFF Disconnecting the fan motor connector / Failure of indoor fan motor lock Refrigerant leakage sensing error Refrigerant leakage sensing error and sensor defect error Communication defect in indoor communication PCB outdoor communication PCB Communication error in outdoor communication PCB outdoor unit Indoor communication PCB did not receive signal from outdoor communication PCB for over 3 minutes continuously Outdoor communication PCB did not receive communication signal from outdoor unit for over 3 minutes continuously 23
24 P/NO : MFL JUNE, 2014
Multi V Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU053TR*2 ARNU073TR*2 ARNU093TR*2 ARNU123TR*2 ARNU153TQ*2 ARNU183TQ*2 CAUTIN Before Servicing the unit,
More informationMulti Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : AMNW12GTRA0(LMCN125HV) AMNW18GTQA0(LMCN185HV) CAUTIN Before Servicing the unit, read the safety precautions
More informationDUCTED INDOOR UNIT ENGINEERING MANUAL
EM_MultiV_Ducted_IndoorUnits_4_16 DUCTED INDOOR UNIT ENGINEERING MANUAL High Static Ducted 7,500 to 95,900 Btu/h Low Static Ducted 7,500 to 24,000 Btu/h Low Static Built In Ducted 7,500 to 24,200 Btu/h
More informationRoom Air Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W363DGU1(Set) ASNW363DGU1 ASUW363DGU1 AS-W303DGU1(Set) ASNW303DGU1 ASUW303DGU1 CAUTION Before Servicing
More informationRoom Air Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W093F2B2(LAN090HVP/LAU090HVP) AS-W123F2B2(LAN120HVP/LAU090HVP) CAUTION Before Servicing the unit, read
More informationMulti Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : L8UC100BFA3 L8UC100BFE3 CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual.
More informationSVC MANUAL(Exploded View) Room Air Conditioner
Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W243D8B8(LSN240HSV3/ LSU240HSV3) AS-W303D8B8(LSN307HV3/ LSU307HV3) AS-W363D8B8(LSN360HV3/ LSU360HV3)
More informationMulti Air Conditioner SVC MANUAL(Exploded View)
http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : L8UC150BFA1 CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service
More informationRoom Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MDEL : ASW093MMB8(LAN090HYV/LAU090HYV) ASW123MMB8(LAN120HYV/LAU120HYV) CAUTIN Before Servicing the unit, read the
More informationMulti Zone Air Conditioner SVC MANUAL(Exploded View)
Multi Zone Air Conditioner SVC MANUAL(Exploded View) CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel. MDEL : MR36TQY3JM 960-920-04
More informationMulti Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A4UW246FA3 CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for
More informationUniversal Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Universal Air Conditioner SVC MANUAL(Exploded View) MDEL : AUUH488D(UU48 U3D) CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual.
More informationUniversal Air Conditioner SVC MANUAL(Exploded View)
http://biz.lgservice.com Universal Air Conditioner SVC MANUAL(Exploded View) MDEL : AUUW306C (UU30W UEC) CAUTIN Before Servicing the unit, read the safety precautions in Standard SVC manual. nly for authorized
More informationAir Conditioning System
For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 00 Air Conditioning System 00 Air Conditioning System Enjoy a clean
More informationSVC Manual (Exploded View)
SVC Manual (Exploded View) TYPE : WALL MOUNTED Applied Models : M09YJ M12YJ M09CJ M12CJ FAC P/no : 960-920-00 Product Specifications FAC Model Name System M09CJ M12CJ M09YJ M12YJ Outdoor Unit MR09C1J MR12C1J
More informationMulti Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A2UW18GFA0 [LMU18CHV] CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual.
More informationSingle A Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Single A Air Conditioner SVC MANUAL(Exploded View) MDEL : AUUH306D(UU30 UED) CAUTIN Before Servicing the unit, read the safety precautions in Standard SVC manual.
More informationRoom Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MDEL : AS-W093E*H0 (LAN095HV / LAU095HV) AS-W123E*H0 (LAN125HV / LAU125HV) CAUTIN Before Servicing the unit, read
More informationEngineering Data Book
40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationFault Codes. J control
J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 Enter unit inspection mode by pushing the UP and DOWN buttons simultaneously for two seconds. Ensure that the
More informationMulti Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A4UW36GFA0 [LMU36CHV] CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual.
More informationEngineering Data Book
40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationMulti Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A7UW40GFA0 [FM40AH U2] CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual.
More informationAir Conditioning System
Outdoor Unit For continual product development, LG reserves the right to change specifications without notice. LG Electronics Inc. Printed in Korea December. 00 Designed by crimad. 0 MULTI V MINI MULTI
More informationIndoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.
Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant
More informationEngineering Data Book
40VMM Medium Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationRoom Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MDEL : ASW1868RH1(C18AWR N81/C18AWU U81) CAUTIN Before Servicing the unit, read the safety precautions in General
More informationSVC Manual (Exploded View)
SVC Manual (Exploded View) Model: M24YJ M30YJ M36YJ FAC P/no : 960-920-02 Product Specifications System 24k 30k 36k FAC Model Name System M24YJ M30YJ M36YJ Outdoor Unit MR24Y3J MR30Y3J MR36Y3J Indoor Unit
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More informationMulti Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.co Multi Air Conditioner SVC MANUAL(Exploded View) MDEL : A9UW566FA3[FM56AH U33] CAUTIN Before Servicing the unit, read the safety precautions in Standard SVC anual.
More informationTechnical Service Manual
Technical Service Manual 60 Hz Low/Mid Pressure Duct Units 7 48 MBH Units 96 MBH Unit June 2009 VRF-SVM21A-EN Low and Mid Pressure Duct Units 1. Features......... 2 2. Specifications......... 3 3. Dimensions.........
More informationMulti Zone Air Conditioner SVC MANUAL(General)
Multi Zone Air Conditioner SVC MANUAL(General) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 960-920-08 Air Conditioner Service
More informationCEILING CONCEALED SPLIT SYSTEM C SERIES
CEILING CONCEALED SPLIT SYSTEM C SERIES Microprocessor Controlled ith the microprocessor controlling the operation, the ACC model can offer comfortable room conditions according to the needs of the user.
More informationLow Static Built In Ducted 7,500 to 24,200 Btu/h Vertical / Horizontal Air Handler 12,000 to 54,000 Btu/h
EM-MultiV-Ducted-IndoorUnits-02-15 Ducted INDOOR UNIT Engineering Manual High Static Ducted 7,500 to 95,900 Btu/h Low Static Ducted 7,500 to 24,000 Btu/h Low Static Built In Ducted 7,500 to 24,200 Btu/h
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2013.12 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics
More informationMulti Zone Air Conditioner SVC MANUAL(General)
Multi Zone Air Conditioner SVC MANUAL(General) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 960-914-09 Air Conditioner Service
More informationDriving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan
Driving and Connecting Globally Fan Coil Unit : PHW-K Size : 510CMH~2720CMH Made in Taiwan Features Superior low-height design. Stainless steel drain pan for condensate and corrosion protection. Flexibe-reverse
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More informationLow Static Pressure Duct(V shape evaporator)
Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...
More informationHigh Static Pressure Duct Fan Coil Unit
MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4
More informationProduct Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015
Product Catalog Variable Refrigerant Flow (VRF) Mid-Static Concealed (Ducted) Indoor Units Indoor Unit Model number: 4TVD****C***** November 2015 VRF-PRC026A-EN Introduction Trane variable refrigerant
More informationLG HVAC SOLUTION. LG Electronics. Distributed by. Copyright 2017 LG Electronics. All rights reserved.
2 0 1 7 2017 LG HVAC SOLUTION LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. ULTIMATE INVERTER COMPRESSOR As the core technology
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationPRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)
PRK 00-04 PREVIEW System OZONE FRIENDLY R-407C Series Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) 3DUW#4 2XWGRRU#8QLWV 111111111111111111111111111111111111111111111111111111111111111111111
More informationFour-Way Ceiling Cassette
Benefits of Multi F Systems Individual zone control Operating ranges of 14 F to 118 F in cooling and 0 F to 64 F in heating Quiet and comfortable environment Safer and easier installation with Cost efficient
More informationTechnical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping
More informationLG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units
Universal and Multi Split Units If there is a fault on any LG Universal or Multi unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller
More informationDucted Type (50Hz, R22/R410A)
Engineering Product Data R-410A Ducted Type (50Hz, R22/R410A) Replaces 5CSDR-01A Introduction Introduction Preface New era brings the more sophisticated and advanced buildings which in turn demands for
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationSPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU18RLF ASU24RLF AOU18RLXFW AOU24RLXFW R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL OPERATION
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASH9LSACW ASH12LSACW Outdoor unit AOH9LSAC AOH12LSAC CONTENTS SPECIFICATIONS...................... 1 DIMENSIONS..........................
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR OUTDOOR 1. INDOOR UNIT : DTR_AS046E_02 2010.12.02 1. INDOOR UNIT CONTENTS 1. FEATURE... 01-01 2. WIRELESS REMOTE CONTROLLER... 01-03 3.
More informationLow Static Pressure Duct (V shape evaporator)
MCAC-VTSM-2015-04 Low Static Pressure Duct Type Low Static Pressure Duct (V shape evaporator) 1. Features... 100 2. Specifications... 101 3. Dimensions... 105 4.Service Spaces... 106 5.Piping Diagrams...
More information1. Features Specifications Dimensions Service Spaces Piping Diagrams Wiring Diagrams...
MCAC-VTSM-2013-08 1. Features... 264 2. Specifications... 265 3. Dimensions... 268 4. Service Spaces... 272 5. Piping Diagrams... 273 6. Wiring Diagrams... 274 7. Capacity Tables... 276 8. Electrical Characteristics...
More information1. Unit selection (based on cooling load)
. Outdoor unit 1. Unit selection (based on cooling load) 11. Indoor unit selection Select the indoor unit based upon cooling load and unit capacity. (The indoor unit capacity should larger than the load.)
More informationDUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-90EB RO-90EPB C O N T E N T S SPECIFICATIONS... OUTLINE AND DIMENSIONS... CIRCUIT DIAGRAM...5 REFRIGERANT SYSTEM DIAGRAM...6
More informationMidea VRFs/ Midea V5X. Timothy Huang Senior Engineer
Midea VRFs/ Midea V5X Timothy Huang Senior Engineer VRF Product Overview General Features V5X Key Technologies V5X VRF product strategy VRF line-up Fresh air solutions Selection software Unique Innovations
More information6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH
CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration
More informationV33B High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven
More informationLG Power Distribution Indicator
Visit us at : http://www.lgservice.com LG Power Distribution Indicator LG OWNER'S & INSTALLATION MANUAL Models: PQNUD1S00 IMPORTANT Please read this user's manual completely before installing the product.
More informationLG Multi Split Air Conditioners
AUS-MUF111 New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 266 PH : 02-8805-4000 FAX : 02-8805- Queensland 23 Terrace Place MURARRIE QLD 4 PH : 0-8-000 FAX : 0--41 Victoria 3 John Deere
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationDriftsinstruks. Utopia kontroller feilkoder PCP-2HTE og PC-ART. Vi håper de får stor glede av et Novema kulde produkt!
Driftsinstruks Utopia kontroller feilkoder PCP-2HTE og PC-ART Vi håper de får stor glede av et vema kulde produkt! www.novemakulde.no 8/14 TROUBLESHOOTING 8.2. TROUBLESHOOTING PROCEDURE 8.2.1. ALARM CODE
More informationVRF. Technical Data Book. Duct S for Europe (R410, 50Hz)
VRF Technical Data Book Duct S for Europe (R410, 50Hz) Version Modification Date Remark Ver.1.0 Release VRF DVM S IDU Duct S for Europe (R410A, 50Hz) TDB 14.09.22 Ver.1.1 External Pressure Minimum data
More informationDVM. Technical Data Book
DVM Technical Data Book Outdoor Units I. Products 1 2 3 Outdoor units Indoor units Accessories 6 7 9 2 II. Outdoor units 1 2 3 4 5 6 Specifications Operation limit Electrical wiring diagram Sound level
More informationVRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series
VRF Indoor Unit 50Hz Type: Wall Mounted M Series Wall Mounted S Series Contents 01 Wall Mounted M Series 20 Wall Mounted S Series MCAC-VTSM-2016-05 Wall Mounted M Series Wall Mounted M Series 1. Features...
More informationDC INVERTER DUCTED AIR CONDITIONERS
DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies
More informationLG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units
Universal and Multi Split Units If there is fault on any LG universal or multi unit a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the
More informationSINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)
SINGLE Technical Data Book 4Way Cassette S for Nordic (R4A, 5Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) History Version Modification Date Remark Ver.1. Released SINGLE for Nordic TDB 15.3.. Ver.1.1
More informationVMDA Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the
More informationLG MULTI SPLIT SYSTEM
50Hz LG MULTI SPLIT SYSTEM Unlike traditional multitype units, it is a nextgeneration multitype airconditioner designed to be installed under any circumstance. LG Multi Split System Why? LG Multi World
More informationSERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI
SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI SERVICE INSTRUCTION Models Indoor unit Outdoor unit ASU7RLF ASU9RLF ASU2RLF ASU8RLF
More information2 1/2 Ton Convertible Air Handler TAM7A0B30H21SD Standard Coil TAM7A0B30H21EA Black Epoxy Coil
Specification 2 1/2 Ton Convertible Air Handler TAM7A0B30H21SD Standard Coil TAM7A0B30H21EA Black Epoxy Coil SAFETY WARNING TAG: Only qualified personnel should install and service the equipment. The installation,
More informationTechnical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4
More informationRESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS
RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS A Better Life, A Better World As we move towards our Centenary in 2018, our new brand slogan encapsulates Panasonic s
More informationmodular multi intelligent, environmental and versatile
modular multi intelligent, environmental and versatile system overview 2-pipe R407C heat pump VRF system From 8 to 46 HP in one piping system (19 steps) Active leak detection system option Up to 40 indoor
More informationMidea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual
Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without incurring
More informationVHIA High-Static Ducted Indoor Units - 60HZ
PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage
More informationPREMIUM INVERTER DUCTED AIR CONDITIONING
PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic
More informationStylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a
Stylus 4G Mini Split Air Conditioners Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a Stylus 4G Comfort Solutions Trane proudly presents the Stylus 4G air conditioners
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationSuperior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A
Superior Performance in Extreme Temperature Submittal Data: 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationR22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]
R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1
More informationAir Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB
Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQA3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB TABLE OF CONTENTS FXDQ-A3 1 Features.............................................................
More informationSERVICE MANUAL MODEL : ARUB Series(Heat Recovery)
Internal Use Only http://biz.lgservice.com Outdoor Unit R410A SERVICE MANUAL MODEL : ARUB Series(Heat Recovery) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only
More informationVersion Modification Date Remark
Version Modification Date Remark Index 1 Nomenclature 2 Specifications 3 Capacity table 4 Dimensional drawing 5 Electrical wiring diagram 6 Sound pressure level 7 Temperature and air flow distribution
More informationSPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................
More informationR-22, 13 SEER 60 Hertz
TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point
More informationProduct Brochure 2018
Product Brochure 2018 2018 Brand Story - 2 - HEALTH Air Filter COMFORT Auto mode heating or cooling. and other materials. Wi-Fi Control Compatible to the Internet Evaporator self-cleaning ENERGY DRED Soft
More informationProduct Data. Convertible Air Handlers 1 1/2 5 Ton D-EN. September 2016
Product Data Convertible Air Handlers 1 1/2 5 Ton TEM6A0B24H21S TEM6A0B30H21S TEM6A0C36H31S TEM6A0C42H41S TEM6A0C48H41S TEM6A0D48H41S TEM6A0C60H51S TEM6A0D60H51S The TEM6 series air handler is designed
More informationMulti-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9
ALDI # CITY, STATE SUPERMARKET MultiPath RTUTYPE 9 (RTU1) CESMPU025REVAV9 Date: December 1, 2014 2013 Consolidated Energy Solutions, Inc. UNIT FEATURES CES TYPE VAV9 Unit features include: 25 ton MultiPath
More informationMULTI SPLIT SYSTEM AIR CONDITIONERS
MULTI SPLIT SYSTEM AIR CONDITIONERS Come home to comfort with LG The Total HVAC and Energy Solution Provider Ever since manufacturing orea s first homegrown air conditioner in 1968, L has remained at the
More informationCeiling Concealed Chilled Water Fan Coil Unit
Technical Manual MODELS: ACW200 ACW300 ACW400 ACW600 ACW800 ACW1000 ACW1200 Air Flow: 112~2040 m 3 /h ACW - C/F/H - 2009-001 Ceiling Concealed Chilled Water Fan Coil Unit Contents Nomenclature... 2 Features...
More informationDC INVERTER VRF SYSTEMS C-VRF
DC INVERTER VRF SYSTEMS C-VRF Index VRF System Overview 4 C-VRF 9 Advantages 10 Benefits For Users 14 Benefits For Installers 18 C-VRF MINI 27 Advantages 28 Indoor Units 33 Indoor Units Line Up 34 Indoor
More informationVWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ
PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three
More informationHAN-L62 MOUNTING PLATE
DATE : 23/01/2013 BULLETIN NO : L62-132E-INST-REV11 SUPERSEDES : 30/11/2012 Z ABN 92 431 001 201 INSTALLATION INSTRUCTIONS FOR MODEL HAN-L62 / PCB-132 WITH EARTH SHIELD CABLE MICROPROCESSOR AIR CONDITIONING
More informationVRF. Technical Data Book. DVM IDU_Vertical AHU for NA (R410A, 60Hz, HP) Model : AM***JNZDCH/AA
VRF Technical Data Book DVM IDU_ for NA (R4A, 6Hz, HP) Model : AM***JNZDCH/AA Version Modification Date Remark Ver.. Release DVM Indoor Unit_ TDB for America 5. 6.. Ver.. Modification for Heater kit (option)
More informationVRF. Technical Data Book. DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz)
VRF Technical Data Book DVM Indoor Unit PAC for Global (INV, R410A, HP) Model : AM140JNPDKH/TK (50/60Hz) AM280JNPDKH/TK (50Hz) History Version Modification Date Remark Ver.1.0 Release DVM Indoor PAC for
More informationVRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***
VRF Technical Data Book Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH*** History Version Modification Date Remark Ver.1.0 Release Ceiling for America (R410A, 60Hz, HP) 15.11.04 - 1 Nomenclature
More information