Particular requirements (apply as applicable to luminaire type) Emergency Escape Lighting and Exit Signs for Buildings

Size: px
Start display at page:

Download "Particular requirements (apply as applicable to luminaire type) Emergency Escape Lighting and Exit Signs for Buildings"

Transcription

1 LUMINAIRES IEC and AS/NZS Luminaires General requirements and tests IEC and AS/NZS Particular requirements (apply as applicable to luminaire type) IEC CISPR 15, EN and AS/NZS CISPR 15 (requirements align) Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment IEC CISPR TR 30 Test method on electromagnetic emissions from electronic ballasts for single- and double-capped fluorescent lamps AS Emergency Escape Lighting and Exit Signs for Buildings IEC 61547, EN Equipment for general lighting purposes - EMC immunity requirements IEC, EN, AS/NZS Limits for harmonic current emissions (equipment input current 16A per phase) COMPONENTS AS/NZS 4783 part 1 Performance of Electrical Lighting Equipment Ballasts for fluorescent lamps where Part 1 Test method Part 2 Energy labelling and minimum energy performance AS/NZS 4879 part 1 ELV Transformers Energy Performance of transformers and electronic step-down convertors for ELV lamps AS/NZS 4847 part 1 Self-ballasted lamps for general lighting services - Minimum Energy Performance Standards (MEPS) requirements AS NZS 4934 part 1 Incandescent lamps for general lighting services - Test methods - Energy performance IEC and AS/NZS Glow-starters for Fluorescent Lamps IEC and AS/NZS Ballasts for Tubular Fluorescent Lamps IEC and AS/NZS Ballasts for discharge lamps (excluding tubular fluorescent lamps) 10.9 IEC and AS/NZS Ballasts for discharge lamps (excluding tubular fluorescent lamps)

2 IEC and AS/NZS DC Supplied Electronic Ballasts for Tubular Fluorescent Lamps IEC and AS/NZS Starting devices other than glow-starters) IEC and AS/NZS AC supplied electronic ballasts for tubular fluorescent lamps IEC and AS/NZS AC supplied electronic ballasts for tubular fluorescent lamps IEC and AS/NZS Auxiliaries for lamps DC and AC supplied electronic step down converters for filament lamps IEC and AS/NZS DC and AC supplied electronic step down converters for filament lamps IEC and AS/NZS Capacitors for use in tubular fluorescent and other discharge lamp circuits IEC and AS/NZS Capacitors for use in tubular fluorescent and other discharge lamp circuits IEC and AS/NZS (IEC :2000, MOD) (apply as applicable to control gear type) IEC and AS/NZS Particular requirements for starting devices (other than glow starters) IEC and AS/NZS Particular requirements for DC or AC supplied electronic step-down convertors for filament lamps (IEC , Ed. 1.2 (2006) MOD) IEC and AS/NZS Particular requirements for AC supplied electronic ballasts for fluorescent lamps IEC and AS/NZS Withdrawn at IEC and is being withdrawn by AS/NZS. Replaced by IEC Particular requirements for DC supplied electronic ballasts for general lighting EC and AS/NZS Withdrawn at IEC and is being withdrawn by AS/NZS. Replaced by IEC Particular requirements for DC supplied electronic ballasts for public transport lighting

3 IEC and AS/NZS Withdrawn at IEC and is being withdrawn by AS/NZS. Replaced by IEC Particular requirements for DC supplied electronic ballasts for aircraft lighting IEC Particular requirements for DC supplied electronic ballasts for Emergency lighting IEC and AS/NZS Particular requirements for ballasts for fluorescent lamps (IEC :2000, MOD) IEC and AS/NZS Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps) (IEC :2000 MOD) IEC and AS/NZS Part 2-13: Particular requirements for DC or AC supplied electronic control gear for LED modules IEC and AS/NZS Safety of Power Transformers, Power Supplies, Reactors and Similar Products General requirements and test (IEC Ed 2, MOD) IEC and AS/NZS Safety of Power Transformers, Power Supply Units and Similar Products Particular requirements 10.11

4 APPLICATION AS/NZS Introduction AS/NZS Vehicular Traffic (Category V) Lighting Performance and design requirements AS/NZS Vehicular traffic (Category V) lighting Guide to design, installation, operation and maintenance AS/NZS Computer procedures for the calculation of light technical parameters for Category V and Category P lighting AS/NZS Pedestrian area (Category P) lighting Performance and design requirements AS/NZS Lighting of pedestrian crossings AS/NZS Part 6: Luminaires AS/NZS Safe movement (Referenced by ABCB National Construction Code) AS/NZS General principles and recommendations 10.12

5 AS/NZS Circulation spaces and other general areas AS/NZS Office and screen-based tasks AS/NZS Educational and training facilities AS/NZS Industrial tasks and processes AS/NZS Hospital and medical tasks AS Measurement, calculation and presentation of photometric data AS/NZS Maintenance of electrical lighting systems AS/NZS Outdoor workplace lighting AS Emergency Escape Lighting and Exit signs for Buildings System design, installation and operation (Referenced by ABCB National Construction Code) AS/NZS Emergency Evacuation Lighting for Buildings Inspection and maintenance AS General principles AS Lighting for outdoor tennis AS Guide to Lighting of multipurpose indoor sports centres AS Lighting for football (all codes) AS Guide to Lighting for outdoor netball and basketball

6 AS Swimming pools AS Guide to Baseball and softball AS Guide to Outdoor hockey AS Outdoor bowling greens AS 4282 Control of the obtrusive effects of outdoor lighting 10.14

LIST OF PUBLISHED STANDARDS

LIST OF PUBLISHED STANDARDS Report : 08-05-0 Page o : Of LST OF PUBLSHED STDRDS Total Count: 59 umber SS umber nt pproved mendment SBS/TC 06 SS 787:005.0 Ophthalmic lenses 005-09-6 005-09-6 07-0-6 SS 97-:0.0 Signs for street and

More information

Spiral T2 10,000 & 8,000 hours

Spiral T2 10,000 & 8,000 hours GE Lighting Spiral T2 10,000 & 8,000 hours Compact Fluorescent Lamps Integrated 8W, 12W, 15W, 20W and 23W for EU DATA SHEET information The T2 10,000 & 8,000 hours spiral lamps are one of the most popular

More information

Product Overview. Key Features. (ship.unit) PARATHOM MR ,5 W 2700 K 210 GU mm 50 mm 32 g

Product Overview. Key Features. (ship.unit) PARATHOM MR ,5 W 2700 K 210 GU mm 50 mm 32 g Product Overview Product Wattage CCT lm Base 827 3,5 2700 210 GU5.3 Benefits For all household luminaires Low energy consumption and maintenance costs Long lifetime up to 15 years² Compact 12V-LED reflector

More information

SPECIFICATION SHEET CONTOUR SUSPENDED LINEAR SYSTEM. IP40 RATED IRC. 600mm. 1200mm. 1500mm. 1800mm

SPECIFICATION SHEET CONTOUR SUSPENDED LINEAR SYSTEM.   IP40 RATED IRC. 600mm. 1200mm. 1500mm. 1800mm CONTOUR SUSPENDED Ideal linear fluorescent replacement Continuous light system with connectable modules offered in 600mm, 1200mm, 1500mm & 1800mm Premium aluminium extrusion with high quality polycarbonate

More information

Datasheet. OSRAM SubstiTUBE Trio 2

Datasheet.  OSRAM SubstiTUBE Trio 2 www.osram.com OSRAM SubstiTUBE Trio 2 Datasheet Innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Energy saving potential of up to 60% by replacing T8 fluorescent tubes.

More information

DALI 650mA LED Driver

DALI 650mA LED Driver Installation Guide DGLC650C18DD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095

More information

LED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards

LED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards GE ighting ED T8 BP Tubular lamps DATA SHEET Product information The GE ED T8 range offers safe, reliable and affordable energy saving alternatives to standard Fluorescent T8 lamps. Available in 60cm,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60923 Edition 3.1 2006-09 Edition 3:2005 consolidated with amendment 1:2006 Auxiliaries for lamps Ballasts for discharge lamps (excluding tubular fluorescent lamps) Performance

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 7176-21 Second edition 2009-04-01 Wheelchairs Part 21: Requirements and test methods for electromagnetic compatibility of electrically powered wheelchairs and scooters, and battery

More information

Indicativul și titlul standardului doc.

Indicativul și titlul standardului doc. N/o Data votării Comitetul Tehnic Indicativul și titlul standardului Tipul doc. Pro (P) Contra (C) Votul Abținere (A) Total voturi Votul final (P, C, A) Comentarii Da Nu 1. 2012 04 12 TC 88 IEC 61400 23

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification 1, Place des Alpes CH-1211 Geneva Switzerland Contact: Patricia Lumbreras Tel: +(511) 221 1159 E-Mail: patricia.lumbreras@sgs.com Locations where

More information

CATALOGUE OF STANDARDS OF CENELEC / TC9X January Documents directly steered by TC 9X 2, 3, 4, 5. Documents steered by CLC / SC 9XA 6, 7

CATALOGUE OF STANDARDS OF CENELEC / TC9X January Documents directly steered by TC 9X 2, 3, 4, 5. Documents steered by CLC / SC 9XA 6, 7 Title of TC9X: Electrical and electronic applications for railways. CLC/TC9X/Sec/679/INF Scope of TC9X: Standardisation of electrical and electronic systems, equipment and associated software for use in

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

DALI Switch Mechanisms DCDAL31 Series Installation Instructions

DALI Switch Mechanisms DCDAL31 Series Installation Instructions DALI Switch Mechanisms DCDAL31 Series Installation Instructions www.clipsal.com.au Contents 1.0 Description...3 1.1 Product Range...3 1.2 DCDAL31 Switch Mechanisms...3 1.3 Safety Information...3 2.0 Installation

More information

PARATHOM CLASSIC A60 advanced frosted PROMO. Product Overview. Key Features. (ship.unit) E27 60 mm 110

PARATHOM CLASSIC A60 advanced frosted PROMO. Product Overview. Key Features. (ship.unit) E27 60 mm 110 Product Overview Product Wattage CCT lm Base PARATHOM CLASSIC A60 adv 10 2700 806 E27 frosted E27 Benefits For all household luminaires Low energy consumption and maintenance costs Longer lifetime² GLS

More information

Background information on GRE/2012/44 (EMC) October Proposal for the 05 series of amendments of Regulation No. 10

Background information on GRE/2012/44 (EMC) October Proposal for the 05 series of amendments of Regulation No. 10 Informal document GRE-68-19 (68th GRE, 15-18 October 2012, agenda item 18(f)) Background information on GRE/2012/44 (EMC) Proposal for the 05 series of amendments of Regulation No. 10 October 2012 Objective

More information

TECTONIC LED CORP. ISO

TECTONIC LED CORP. ISO TECTONIC TECTONIC LED CORP. ISO 9001:2000 Products RoHs Compliance Instruction Menu Retrofit:LED Tube Lamps SECTION 1 - General Information Kit components: 1-LED Tube, 1-Label and 1-Set of Instructions

More information

TECHNICAL DATA CRI CURRENT

TECHNICAL DATA CRI CURRENT ACADEMY OPAL PRISM 100mm Ideal replacement for linear fluorescent Designed for surface mounting in office and educational environments Steel backplate with polycarbonate diffuser, secured by screwed endcaps

More information

Product Overview. & clear sparkling. Key Features

Product Overview. & clear sparkling. Key Features Product Overview Product Wattage CCT lm Base PARATHOM CLASSIC A40 adv 6 2700 470 E27 frosted E27 PARATHOM CLASSIC A40 adv clear sparkling E27 6 2700 470 E27 PARATHOM CLASSIC A40 adv frosted E27 6 4000

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

Installation Instructions

Installation Instructions Installation Instructions 03140 EV-MERCURY-III-40M CODE: 03140 CTENTS 1. Welcome 2. Overview 3. Safety warnings 4. Installation 5. Mounting options 6. Terminal block wiring 7. Maintaining your Mercury

More information

Dreamer Series. LED bulb A60. Product benefits. Product features. Product datasheet

Dreamer Series. LED bulb A60. Product benefits. Product features. Product datasheet Product datasheet Dreamer Series LED bulb A60 Product benefits Eye cared lamp design, no UV and IR, reducing photobiology harmful effects to a lower, meet and passed IEC/EN 62471 certification Easeful

More information

Induction lamps and control gear

Induction lamps and control gear Induction lamps and control gear The QL lamp systems are based on a unique physical principle of light generation: the QL induction technology. The QL induction technology is a breakthrough for professional

More information

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4 Data sheet Integrated emergency converter for fluorescent lamps zone 2 Ex 100,000 h suitable for zone 2 hazardous areas For mains and battery supply Integrated battery management inear V inear V Emergency

More information

DRAFT. Installation Instructions 1693 EV-LEDFIRE-III 1694 EV-LEDFIRE-III-PRO 1697 EV-LEDFIRE-III-PRO-B 1695 EV-LEDFIRE-III-ULT CONTENTS 1.

DRAFT. Installation Instructions 1693 EV-LEDFIRE-III 1694 EV-LEDFIRE-III-PRO 1697 EV-LEDFIRE-III-PRO-B 1695 EV-LEDFIRE-III-ULT CONTENTS 1. Installation Instructions 1693 EV-LEDFIRE-III 1694 EV-LEDFIRE-III-PRO 1697 EV-LEDFIRE-III-PRO-B 1695 EV-LEDFIRE-III-ULT CODE:1694 CODE:1697 CTENTS 1. Welcome 2. Overview 3. Safety warnings 4. Installation

More information

Ecoglo HYU Hybrid Photoluminescent Exit Signs: Compliance with NZBC F8/AS1

Ecoglo HYU Hybrid Photoluminescent Exit Signs: Compliance with NZBC F8/AS1 Ecoglo International Ltd 77 Kingsley Street, Christchurch New Zealand +64 3 348 3781 mark.watson@ecoglo.com www.ecoglo.co.nz 7 th September 2017 Ecoglo HYU Hybrid Photoluminescent Exit Signs: Compliance

More information

This standard covers the requirements of luminaires for emergency lighting chains. This standard covers safety and performance requirements.

This standard covers the requirements of luminaires for emergency lighting chains. This standard covers safety and performance requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of luminaires for emergency lighting chains. This standard covers safety and performance requirements. This standard (Part

More information

LED T8 Full Glass Tube

LED T8 Full Glass Tube ED T8 Full Glass Tube Product Code Watts (W) Installation Instructions: Volts (V) Cap Colour Appearance Colour Temp (K) ED T8 full glass tube providing 320 light output. Energy saving with low power consumption.

More information

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

SPECIFICATION SHEET ORION ROAD LANTERN.   IP66 RATED CRI. 230v /50hz ORION ROAD LANTERN Arc shape cooling guide design, resulting in effective heat dissipation and dust removal ability Combined optical lens, ideal for road lighting requirements Power-off protection socket,

More information

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps Reliability with the most essential intellect Philips HF-Essential Electronic ballasts for TL5 lamps HF-Essential - Reliability with the most essential intellect Electronic ballasts for TL5 lamps The cost-saving

More information

Prosport LED INTRODUCTION APPLICATION SPECIFICATION PRODUCT SPECIFICATION

Prosport LED INTRODUCTION APPLICATION SPECIFICATION PRODUCT SPECIFICATION INTRODUCTION In any sporting application high quality lighting is critical to ensure a satisfactory player experience. The offers a range of distributions and up to 34,500 lumen output allowing your scheme

More information

Lighting circuits. The different lamp technologies

Lighting circuits. The different lamp technologies Lighting circuits A source of comfort and productivity, lighting represents 10% of the quantity of electricity consumed in industry and 40% in buildings. The quality of lighting (light stability and continuity

More information

Luminaires CG-S Eaton. All Rights Reserved.

Luminaires CG-S Eaton. All Rights Reserved. Luminaires CG-S Agenda Applications / Requirements Luminaire Portfolio GuideLed Plastic Luminaires Escape Sign Panel Luminaires, LED Aluminium Luminaires Downlights Escape Sign Cubes Luminaires with High

More information

Product Information. PARATHOM MR & 24 Adv. Product Overview. Benefits. Key Features

Product Information. PARATHOM MR & 24 Adv.   Product Overview. Benefits. Key Features Product Overview Product Wattage CCT in K lm Beam Base Angle 35 24 6,5 2700 350 24 U5.3 6,5 2700 350 36 U5.3 6,5 3000 350 36 U5.3 6,5 4000 350 36 U5.3 Benefits True replacement of low voltage halogen MR16W

More information

Product Description. MASTER TL-D Super 80. Low-pressure mercury discharge lamps with a tubular 26 mm envelope

Product Description. MASTER TL-D Super 80. Low-pressure mercury discharge lamps with a tubular 26 mm envelope Product Description MASTER TL-D Super 80 Low-pressure mercury discharge lamps with a tubular 26 mm envelope Benefits Special fluorescent coating gives good colour rendering Relatively high efficacy, both

More information

Amendment to Schedule 15 for Ballasts Electromagnetic & Electronic ballasts

Amendment to Schedule 15 for Ballasts Electromagnetic & Electronic ballasts Revision 1 Date: 28/01/2016 Amendment to Schedule 15 for Ballasts Electromagnetic & Electronic ballasts In the said schedule, (i) in paragraph 7, for sub-paragraph (i) the following shall be substituted,

More information

650mA Phase Dimmable LED Driver

650mA Phase Dimmable LED Driver Installation Guide DGLC650C18PD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095

More information

Product Description. MASTER TL-D 90 De Luxe. Benefits. Features. Application. Low-pressure mercury discharge lamps with a tubular 26 mm envelope

Product Description. MASTER TL-D 90 De Luxe. Benefits. Features. Application. Low-pressure mercury discharge lamps with a tubular 26 mm envelope Lighting Product Description Low-pressure mercury discharge lamps with a tubular 26 envelope Benefits Very good colour rendering. Making colours appear rich, deep and enhanced as they do in daylight, making

More information

IP65 FLUO 2X18W 2X36W

IP65 FLUO 2X18W 2X36W IP65 FLUO 2X18W 2X36W Features Housing made of reinforced polyester glass fiber (GRP) High transparent and impact resistant PC diffuser Both standard and emergency modes available Operation and survive

More information

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE:

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: THE HIGH PERFORMANCE LED Fixture Series (surfacemount or hung) for Passageway, Stairwells, General, Direct and Indirect Illumination KEY FEATURES INCLUDE: Advanced Thermal Management Industry Leading Deep

More information

A7 Magnetic Contact/Switch CONTENTS

A7 Magnetic Contact/Switch CONTENTS A7 Magnetic Contact/Switch CONTENTS A7-02 Magnetic Contact / Switch VMC9~85 Medium/Small Capacity VITZRO Magnetic Contact/Switch provides customers with the safety as the first priority which is the core

More information

SubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M

SubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M SubstiTUBE Value EM T8 (AUS Fighter Tube) ST8V-0.6M ST8V-1.2M ST8V-1.5M Innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Type A design complies with AS/NZS 60598.2.1:2014/

More information

Locations of Reading High School and Reading Middle School Home Athletic Events by Sport (Scroll Down for Directions to Each Venue.

Locations of Reading High School and Reading Middle School Home Athletic Events by Sport (Scroll Down for Directions to Each Venue. Locations of Reading High School and Reading Middle School Home Athletic Events by Sport (Scroll Down for Directions to Each Venue.) JV and Varsity Basketball, Volleyball, and Wrestling Reading High School

More information

1000mA - 650mA Phase Dimmable LED Driver

1000mA - 650mA Phase Dimmable LED Driver Installation Guide DGLC1000C25PD 1000mA - 650mA Phase Dimmable LED Driver PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

LED 2/3/4ft T8 Tube 120V

LED 2/3/4ft T8 Tube 120V E-T8-1200-YR LED 2/3/4ft T8 Tube 120 Our LED Tubes utilize the latest LED chips as the light source, whilst using the standard T8 end caps, which makes it easy to install and replace traditional fluorescent

More information

Standards, Regulations and Labelling Requirements for Lighting Products Irosha S. Kalugalage

Standards, Regulations and Labelling Requirements for Lighting Products Irosha S. Kalugalage Standards, Regulations and Labelling Requirements for Lighting Products Irosha S. Kalugalage Sri Lanka Sustainable Energy Authority Content of Presentation 2 Lighting Products with National Standards in

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60034-1 Eleventh edition 2004-04 Rotating electrical machines Part 1: Rating and performance This English-language version is derived from the original bilingual publication

More information

Installation Instructions

Installation Instructions SOLAR GARDEN POWER CELL SKU#229120 Rated Voltage 12VDC Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions carefully before

More information

An Overview of Automotive EMC Standards & Emerging Requirements

An Overview of Automotive EMC Standards & Emerging Requirements An Overview of Automotive EMC Standards & Emerging Requirements 2015. 5. 29 Korea Automobile Testing & Research Institute (KATRI) TOPICs 1. Automotive Electronics of the Future 2. Automotive EMC Standards

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

A List of Standards Often Used for Designing Electrical Systems and for Specifying Equipment

A List of Standards Often Used for Designing Electrical Systems and for Specifying Equipment Appendix B A List of Standards Often Used for Designing Electrical Systems and for Specifying Equipment Note... erence in {} brackets supersede the original references. B.1 INTERNATIONAL ELECTRO-TECHNICAL

More information

Switchgear for Luminaires

Switchgear for Luminaires www.eaton.com www.moeller.net Switchgear for Luminaires Technical Paper Dipl.-Ing. Dirk Meyer Mr. Dirk Meyer (Dipl.-Ing.) Division Industrial Automation Division Electromechanical motor starter product

More information

POWERSTAR HQI -T W Metal halide lamps with quartz technology for enclosed luminaires

POWERSTAR HQI -T W Metal halide lamps with quartz technology for enclosed luminaires l d a l POWERSTAR HQI -T 250 400 W Metal halide lamps with quartz technology for enclosed luminaires d a 1 2 GTIN (EAN) HQI-T 250 W/D PRO 4008321677846 250 19000 E40 46 226 150 A 12 1 HQI-T 250 W/N/SI

More information

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps T5 versus T8 Fluorescent Lamps The good, the bad, & the ugly about T8 and T5 lamps Association of Energy Engineers- Cleveland Chapter Tuesday, February 22, 2005 Presented by: Lewis S. Sternberg, LC Consultants

More information

CATALOGUE.

CATALOGUE. CATALOGUE www.dgr.com.my D TUBE LED D TL2 LED TUBE LED TUBE LIGHTING SERIES FAMILY NAME: LEMNIS TL2 1200 CORRELATED COLOUR TEMPERATURE: 3500K / 4000K / 5000K / 6500K PRODUCT CODE: 2R3MEB / 2R4MEB / 2R2MEB

More information

Instruction/Installation Manual

Instruction/Installation Manual Instruction/Installation Manual Retrofit:LED Tube Lamp 4ft. Fluorescent T8/T10 Replacement 1 SECTION 1 - General Information Kit components:1-led Tube, 1-Label and 1-Set of Instructions Models were only

More information

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVNL LED fitting - zones 2, & 22 65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress

More information

TECHNICAL DATA CRI. 230v /50hz. EFFICACY WATTAGE Llm/W. EFFICACY WATTAGE Llm/W

TECHNICAL DATA CRI. 230v /50hz. EFFICACY WATTAGE Llm/W. EFFICACY WATTAGE Llm/W TECHNICAL DATA CLIMATE SINGLE SINGLE ARRAY TWIN ARRAY Complete with array, ideal replacement for linear fluorescent Designed for surface mount application in industrial and commercial environments Polycarbonate

More information

Lighting Tables for Existing/Base Equipment 1/1/2014

Lighting Tables for Existing/Base Equipment 1/1/2014 T12 Fluorescent Lamps and Fixtures LENGTH Lighting Tables for Existing/Base Equipment OF CODE WATTS LENGTH OF CODE WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO

More information

1992 Energy Policy Act A Pacific Energy Center Factsheet

1992 Energy Policy Act A Pacific Energy Center Factsheet 1992 Energy Policy Act A Pacific Energy Center Factsheet The Energy Policy Act of 1992 affected all users of electric lighting. In addition to instituting requirements for electric motors, utility distribution

More information

PIB5 PIB6 PIB7. Pg

PIB5 PIB6 PIB7. Pg 7.2 Emergency 7.2 7.3 7.3 PEM6 PEM7 PEM8 PEM2 7.4 7.4 7.5 7.5 PIB1 PIB2 PIB3 PIB4 7.5 7.6 7.6 PIB5 PIB6 PIB7 7.7 7.7 1.9 1.9 1.10 1.10 1.11 1.11 1.12 1.10 Pg7 LEGAL REQUIREMENTS The Occupational Health

More information

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011 2CDC 071 020 S0012 The Room Master is a modular installation device (MDRC) in Pro M design. It is intended for installation in the distribution board on 35 mm mounting rails. The assignment of the physical

More information

Product Description. TL-D Standard Colours. Low-pressure mercury discharge lamps with a tubular 26 mm envelope

Product Description. TL-D Standard Colours. Low-pressure mercury discharge lamps with a tubular 26 mm envelope Product Description TL-D Standard Colours Low-pressure mercury discharge lamps with a tubular 26 mm envelope Benefits Create atmospheres from warm white to cool daylight Features Standard colors with moderate

More information

RadioRA 2 Maestro Local Controls

RadioRA 2 Maestro Local Controls RadioRA 2 Maestro local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where single

More information

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality

More information

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Linear fittings EVTL Weatherproof LED fitting - Industrial applications 89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted

More information

LIST OF PUBLISHED STANDARDS

LIST OF PUBLISHED STANDARDS Report : 08-06-08 Page o : Of 8 LIST OF PUBLISHED STDRDS umber SS umber pproved mendment SBS/TC 069 SS 959-:06/RS 05-:0.0 Photovoltaic systems for use in individual homes, schools and clinics Part : 06--8

More information

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR) WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,

More information

Informal document No. 5 (47th GRE, 1-5 October 2001, agenda item 5.8.)

Informal document No. 5 (47th GRE, 1-5 October 2001, agenda item 5.8.) Informal document No. 5 (47th GRE, 1-5 October 2001, agenda item 5.8.) Date: 4-6-01 Subject: Revision of Standards for 42V Automotive Electrical Systems To: Economic Commission for Europe Please recall

More information

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads 22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil

More information

L I G H T W A V UV Electronic Ballast E 2010

L I G H T W A V UV Electronic Ballast E 2010 L I G H T W A V UV Electronic Ballast 2010 E LIGHTWAVE High Frequency Electronic Ballast Function of an UV ballast To provide the proper voltage and current such that a steady plasma can be established

More information

Installation Instructions

Installation Instructions LEDLUX TELLA SKU# 231091, 231093 Rated Voltage 220-240V~ 50Hz Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions carefully

More information

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire

More information

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S T A B L E O F C O N T E N T S A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S LLF755 - Low Level Flood with Anti-Glare Faceplate C1.1 LLF800 - Low Level Flood with Anti-Glare Faceplate

More information

DALI Emergency LED Driver - 350/700/1000mA Constant Current

DALI Emergency LED Driver - 350/700/1000mA Constant Current User and Installation Guide DGLCEM035CD-AU DGLCEM070CD-AU DGLCEM100CD-AU - 350/700/1000mA Constant Current PATENT PENDING/REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation

More information

Product Overview. Product. LED PARATHOM PRO MR16 50 advanced. advanced. advanced. Key Features

Product Overview. Product. LED PARATHOM PRO MR16 50 advanced. advanced. advanced. Key Features Product Overview Product Wattage CCT in K lm Beam Angle Base 12 2700 620 36 GU 5,3 12 3000 620 36 GU 5,3 12 4000 620 36 GU 5,3 Benefits suitable for indoor application. for outdoor applications and operation

More information

OSRAM DULUX L LUMILUX CFLni, with 4-pin 2G11 base for ECG/CCG operation

OSRAM DULUX L LUMILUX CFLni, with 4-pin 2G11 base for ECG/CCG operation OSRAM DULUX L LUMILUX CFLni, with 4-pin 2G11 base for ECG/CCG operation l 38 43,9 23,6 1 17,5 23,6 Product name GTIN (EAN) DULUX L 18 W/827 2G11 1) 531748 18 LUMILUX INTERNA 2G11 1 DULUX L 18 W/83 2G11

More information

Lessons Learned in Lighting Equipment Testing in the Philippines

Lessons Learned in Lighting Equipment Testing in the Philippines Lessons Learned in Lighting Equipment Testing in the Philippines Engr. Arturo M. Zabala, PEE Fuels and Appliance Testing Laboratory DEPARTMENT OF ENERGY Lessons Learned in Asia: Regional Symposium on Energy

More information

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short

More information

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Linear fittings EVTL Weatherproof LED fitting - Industrial applications 89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted

More information

INDUCTION FLUORESCENT LAMPS are one of the oldest energy saving lighting technologies in

INDUCTION FLUORESCENT LAMPS are one of the oldest energy saving lighting technologies in INDUCTION FIXTURES INDUCTION OVERVIEW INDUCTION FLUORESCENT LAMPS are one of the oldest energy saving lighting technologies in existence with many years of positive field test results and which has recently

More information

IMPROVED LIGHTING CONTROLS

IMPROVED LIGHTING CONTROLS IMPROVED LIGHTING CONTROLS Lighting controls give you the flexibility to design a space for multiple use and easy access. They should be a part of the lighting plan for every room. Both manual and automatic

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

PC T8 TEC, W PC TEC

PC T8 TEC, W PC TEC T8 TC-L PC T8 TEC, 18 58 W PC TEC Product description CELMA Energy Efficiency Index A2 Nominal life time up to 30,000 h (at ta 50 C with a failure rate max. 0.3 % per 1,000 h) Large temperature range (for

More information

EU RO Mutual Recognition Technical Requirements

EU RO Mutual Recognition Technical Requirements 1. PRODUCT DESCRIPTION... 1 2. DESIGN EVALUATION... 2 3. PRODUCTION REQUIREMENTS... 6 4. MARKING REQUIREMENTS... 6 5. TYPE APPROVAL CERTIFICATE CONTENT... 7 6. APPROVAL DATE AND REVISION NUMBER... 7 7.

More information

Technical specifications

Technical specifications Technical specifications Type 3RW30 03 3RW3-1B0 3RW3-1B1 Control electronics Rated control supply voltage V 24 230 CDC 24 CDC (+10 %-15 %) 110 230 CDC (+10 %-15 %) Rated control supply Without fanwith

More information

Electrical Systems and Fault Finding

Electrical Systems and Fault Finding Unit 31: Unit code Electrical Systems and Fault Finding A/615/1500 Unit level 4 Credit value 15 Introduction Electrical systems can be found in a very wide range of locations such as in manufacturing facilities,

More information

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8

FL ballasts Electronic fixed output PC T8 TEC, W PC TEC T8 T8 TC-L PC T8 TEC, 18 58 W PC TEC T8 Product description CELMA Energy Efficiency Index A2 Nominal life time up to 30,000 h (at ta 50 C with a failure rate max. 0.3 % per 1,000 h) Large temperature range

More information

FLUORESCENT INDUCTION

FLUORESCENT INDUCTION FLUORESCENT INDUCTION Electrodeless Lamp OPENING NEW FRONTIERS FOR LIGHTING IT IS IMPOSSIBLE TO IMAGINE MODERN LIFE WITHOUT ELECTRIC LIGHTING. WITH THE WIDE AVAILABILITY AND AFFORDABILITY OF TODAY S LIGHTING,

More information

Potenza Commercial Pendant Compact Fluorescent, Incandescent, HID Medium, Large

Potenza Commercial Pendant Compact Fluorescent, Incandescent, HID Medium, Large PRODUCT SPECIFICATIONS PENDANT: Extruded aluminum body with silver powder coat finish. Clear prismatic acrylic diffuser dome provides soft self-illumination. MOUNTING: 4 solid square fixture hanger attached

More information

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice. WSV600 Wall Luminaire with Open faceplate 2007.4.13 Applications: Oval Surface Wall Sconce Luminaires are ideal for indoor or outdoor applications in, residential, commercial, or architectural installations

More information

E/ECE/324/Add.5/Rev.6/Amend.2 E/ECE/TRANS/505/Add.5/Rev.6/Amend.2

E/ECE/324/Add.5/Rev.6/Amend.2 E/ECE/TRANS/505/Add.5/Rev.6/Amend.2 5 December 2017 Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and

More information

CCE RR KARNATAKA SECONDARY EDUCATION EXAMINATION BOARD, MALLESWARAM, BANGALORE G È.G È.G È.. Æ fioê, d È 2017

CCE RR KARNATAKA SECONDARY EDUCATION EXAMINATION BOARD, MALLESWARAM, BANGALORE G È.G È.G È.. Æ fioê, d È 2017 CCE RR O %lo ÆË v ÃO y Æ fio» flms ÿ,» fl Ê«fiÀ M, ÊMV fl 560 003 KARNATAKA SECONDARY EDUCATION EXAMINATION BOARD, MALLESWARAM, BANGALORE 560 003 G È.G È.G È.. Æ fioê, d È 017 S. S. L. C. EXAMINATION,

More information

Lighting Tables for New Equipment 7/16/2008

Lighting Tables for New Equipment 7/16/2008 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH 2' F17T8 1 18 200 9.00 --- --- 2 32 201 9.00 --- --- 3 48 202 15.00 --- --- 4 57 203 15.00 --- --- F17T8 with Reflectors 1

More information

Easy and safe installation

Easy and safe installation ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield

More information

EMC for E-mobility. William Radasky presenting for Jacques Delaballe IEC TC 69 representative in ACEC. APEMC Symposium May 2015

EMC for E-mobility. William Radasky presenting for Jacques Delaballe IEC TC 69 representative in ACEC. APEMC Symposium May 2015 INTERNATIONAL ELECTROTECHNICAL COMMISSION EMC for E-mobility William Radasky presenting for Jacques Delaballe IEC TC 69 representative in ACEC APEMC Symposium May 2015 1 Outline IEC bodies involved Situation

More information

6.1. Lighting Contactors. Contents. Application Description. Product Overview. Open Control

6.1. Lighting Contactors. Contents. Application Description. Product Overview. Open Control .1 - Contents Description C30CN Mechanically and Electrically Held.... CN35 Electrically Held.................... A202 Magnetically Latched................ Page V5-T-3 V5-T-1 V5-T-23 Product Overview C30CN

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11068-09-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 10.07.2014 to 09.07.2019 Holder of certificate: Karlsruher

More information