MICRO SWITCH Compact Limit Switches NGC Series Issue 7. Datasheet FEATURES POTENTIAL INDUSTRIAL APPLICATIONS DESCRIPTION DIFFERENTIATION
|
|
- Jane McDaniel
- 6 years ago
- Views:
Transcription
1 MICRO SWITCH Compact Limit Switches NGC Series 0009 Issue 7 atasheet FETURES SPT or PT configurable circuitry Snap-action, positive-break contacts Silver alloy and gold-plated contact options UL, CE, cul, and CCC approvals Conforms to IEC , IEC 673, EN (metal variants with M connectors only) NEM, 4,, ; IP67 sealing Metal and plastic housing options Low and high temperature variants Cable and connector terminations Variety of heads and actuator levers ESCRIPTION Honeywell s MICRO SWITCH Compact Limit Switches, NGC Series, are a configurable platform of medium-duty switches that allow the customer to choose SPT (single pole, double throw) or PT (double pole, double throw) circuitry while maintaining the same housing and mounting footprint throughout the NGC Series. MICRO SWITCH NGC Series can be configured more than 380,000 ways, carries global approvals, and are sealed to IP67 for potential use in indoor and outdoor applications. VLUE TO CUSTOMERS Cost-effective: Provides a single source for a compact SPT and PT limit switch, which can help minimize the Original Equipment Manufacturer s sourcing expenses by simplifying their supply chain Versatile: urable packaging allows for use in many harsh indoor or outdoor applications, providing performance confidence Configurable: llows design engineers to standardize on a single footprint while meeting a variety of electrical requirements pplication support: Customers with a global footprint can count on Honeywell for regional support for new applications and troubleshooting POTENTIL INUSTRIL PPLICTIONS oom position detection Elevators and escalators Machine tools Mobile light towers Packaging equipment Rail doors Scissor lifts IFFERENTITION With two times the vibration (0 g) and shock (50 g) ratings of comparable competitive devices, the NGC Series can be implemented in the harshest of environmental conditions, providing enhanced reliability and repeatability roader current capacity (0 ) than comparable devices allows for potential use in a wider set of applications, making platform standardization an easier task PORTFOLIO The NGC Series joins the CE, 9CE, LS, and E6/V6 Series of Medium-uty Limit Switches. Honeywell also offers a portfolio of MICRO SWITCH Heavy-uty Limit Switches and Global Limit Switches. Sensing and Internet of Things
2 Table. Specifications Characteristic escription ctuators Terminations (SPT) Terminations (PT) Material approval standard Switching options Sealing Contacts sensing.honeywell.com Parameter compact, medium-duty limit switches Side Rotary Configurations Side rotary Side rotary (short) Side rotary with adjustable length roller lever Reversed side rotary (short) Reversed side rotary with adjustable length roller lever Normal cable (refer to table 4) PUR cable (refer to table 4) Special application cable (refer to table 4) Railway cable (refer to table 4) Connector, 4-pin male, M thread Connector, 5-pin male, M thread Normal cable (refer to table 4) PUR cable (refer to table 4) Special application cable (refer to table 4) Railway cable (refer to table 4) Plunger Configurations Pin plunger (standard 4,8 mm [0.9 in] and long 7,4 mm [0.9 in]) Roller plunger (standard 5,3 mm [0.60 in] and long 7,85 mm [0.70 in]) Cross roller plunger (standard 5,3 mm [0.60 in] and long 7,85 mm [0.70 in]) Pin plunger with boot seal Panel-mount pin plunger Panel-mount roller plunger Panel-mount cross roller plunger Panel-mount pin plunger with boot seal Top roller lever arm (only applicable for product with non-halogen cable) IN (flammability rating: S3; smoke rating: > SRI; welt rating: ST; toxic gas rating: FE(TZUL=5min)< ) SPT, PT; snap action contacts (NC/NO, NC/NO) NEM, 4,, ; IP67 per IEC 6059 suitable for outdoor applications snap action, positive break standard: silver alloy; gold: gold-plated Operating temperature -5 C to 75 C [ - F to 67 F] (for extended operating temperature options, see Table 3) Storage temperature Mechanical endurance Electrical life Thermal current Rated insulation voltage (Ui) ielectric strength Impulse voltage Pollution degree Humidity Operating speed Switching frequency Shock Vibration pprovals Conforming to standards -40 C to 85 C [-40 F to 85 F] NC/NO: 5 M cycles min. at 0 CPM NC/NO: 5 M cycles min. at 60 CPM 0 Vdc 500,000 cycles applicable only for NC circuit NC/NO: 0 ; NC/NO: 5 NC/NO: 400 V as per IEC NC/NO: 50 V as per IEC Vac for metal housing; 890 Vac for plastic housing 500 Vac between all terminals to enclsoure after durability test NC/NO: 500 Vdc as per IEC NC/NO: 500 Vac as per IEC (III) 95 %RH 0,3 mm/s to m/s NC/NO: 0 CPM NC/NO: 60 CPM 50 g for ms as per IEC ; railway application, per IEC 673 Class I Car type 0 g as per IEC , frequency range 0 Hz to 500 Hz; railway application per IEC 673 Class I Car type UL (UL508), cul, CE (IEC ), CCC (G ) IEC , IEC 673, EN HL 3 (metal variants with M connectors only)
3 Table. Electrical Ratings Circuitry/contacts NC/NO (silver-alloy contacts) NC/NO (gold-plated contacts) NC/NO (silver-alloy contacts) NC/NO (gold-plated contacts) Rating, Rated Voltage & Current 300 C5: 0 V 6 ; 0 V 3 per IEC and UL508 Q300 C: 5 Vdc 0.55 ; 50 Vdc 0.7 per IEC an UL508 low level current: 30 mvdc 0 m resistive C300 C5: Vac per IEC R300 C: Vdc per IEC low level current: 30 mvdc 0 m resistive Figure. Product Nomenclature and Order Guide NGC M 0 X Switch Type NGC Series Medium-uty Compact Limit Switch P Q Housing M Metal Plastic Plastic with mounting ring support Connection C Side exit, right ottom exit Side exit, left Cable Length No cable. Internal connector 0,5 m [0.8 ft] 0,5 m [.64 ft] 0,7 m [.3 ft],0 m [3.8 ft] 5,5 m [4.9 ft] Connector/Cable Exiting Housing Standard cable Halogen-free cable N P R PUR cable M 4-pin micro change, dc connector 5,6,8 M 5-pin micro change, dc connector 4,6,8 Railway cable7 L40 Connector at End of Cable X None Switch Type NC/NO snap action silver contacts NC/NO snap action gold contacts NC/NO snap action silver contacts NC/NO snap action gold contacts C J L Head Type Side rotary Pin plunger Roller plunger Long pin plunger Top roller lever arm Cross roller plunger Levers (Optional) 6 None Standard, fixed length djustable length, roller lever Short, fixed length Rollers (Optional) C None 8 mm nylon roller 8 mm stainless steel roller 8 mm nylon roller, reversed 3 8 mm stainless steel roller, reversed 3 Modifications Side rotary Mlever, 90 right Side rotary M0lever, 90 left Side rotary Mshort lever, 45 right Side rotary M08short lever, 45 left High temp H85 variant, 85 C 0 Low temp variant, -40 C 0,0 m [6.56 ft] M Pin plunger w/ boot seal NOTE: not all combinations of model code are available. Please contact your Honeywell provider/representative for assistance. 30 3,0 m [9.84 ft] 40 4,0 m [. ft] 50 5,0 m [6.4 ft] N Panel-mount pin plunger Only applicable for head type R Panel-mount pin plunger w/ boot seal Only applicable for lever types,, 6 and switch types and 3 Only applicable for lever types, 6 Long roller 4 Only applicable for metal housing Type M S plunger 5 Typically applicable for plastic housing Type P and Q, and without grounding metal housing Type M 6 Only applicable for switch type and T Long cross-roller 7 Cable meets EN 50306, but does not meet with UL requirement plunger 8 Only applicable for O0 cable length. Not applicable to switch types and 9 00 cable length is not applicable for connector/cable exit type,,, and R. Not applicable to switch types and 0 IN does not apply to NGC variant with suffix modification code H85. lso applicable only for connector/cable types, R, N, and P. See table 3 Modification code L40 is a -40 C variant. Only applicable to connector/cable types, R, N, and P. See table 3 P Q Panel-mount roller plunger Panel-mount cross-roller plunger 0, Table 3. Connector/Cable Type Temperature Options Connector/Cable type Standard NGC Series (with modification code, none) High Temp NGC Series (with modification code, H85) Low Temp NGC Series (with modification code, L40) Tmin Tmax Tmin Tmax Tmin Tmax -5 C 75 C -5 C 75 C -5 C 85 C -40 C 75 C -5 C 75 C R -5 C 75 C -5 C 85 C -40 C 75 C N -5 C 75 C -5 C 85 C -40 C 75 C P -5 C 75 C -5 C 85 C -40 C 75 C Sensing and Internet of Things 3
4 Figure. Connector imensions and Pin-Out Identification 4-Pin Identification 5 [0.59] [0.47] Side Exit 7 [0.67] [0.47] ottom Exit 5-Pin Identification Side Exit ±5 L (Cable Length) ± ± ±5 L (Cable Length) ottom Exit Table 4. Cable escriptions Listing NGC*00* Cable escription Length (L) min. Jacket strip length () no cable (internal connector) Insulation strip length () NGC*0* 0,5 m [9.8 in] 3 mm [0.9 in] 5 mm [0.0 in] NGC*05* 0,5 m [9,7] mm [.6] 7 mm [0.67 in] NGC** 0,7 m [7.6 in] mm [.6] 7 mm [0.67 in] NGC*0* m [39.37 in] 3 mm [0.9 in] 5 mm [0.0 in] NGC*5*,5 m [59 in] 3 mm [0.9 in] 5 mm [0.0 in] NGC*0* m [78.74 in] 3 mm [0.9 in] 5 mm [0.0 in] NGC*30* 3 m [9.84 ft] 3 mm [0.9 in] 5 mm [0.0 in] NGC*40* 4 m [. ft] 3 mm [0.9 in] 5 mm [0.0 in] NGC*50* 5 m [6.4 ft] 3 mm [0.9 in] 5 mm [0.0 in] NGCP** NGCP** ( or switch type) NGCM** NGCM** ( or switch type) NGCP** NGCP** ( or switch type) NGCM** NGCM** ( or switch type) 8 WG or 8 WG or 0 WG or 0 WG or 4 x 0,75 mm 5 x 0,75 mm 8 x 0,5 mm 9 x 0,5 mm 4 sensing.honeywell.com
5 Figure 3. Side Rotary / imensions,5 [.8] FP PT PT 7 [0.8] Figure 4. Side Rotary 6/6 imensions FP PT PT 9,9 [0.78] 7 [0.8] 65,5 [.58] Ø 8 [Ø 0.7] 6,7 [0.66] 5 [.05] Ø 8 [Ø 0.7] 67,4 [.65] 6,7 [0.66] 67,4 [.65] Type / Side Rotary Figure 5. Side Rotary / imensions PT FP 9 [.] PT 7 [0.8] Type 6/6 Side Rotary (Short) Figure 6. Side Rotary 6C/6 imensions FP 0,8 [0.43] PT PT 7 [0.8] 5 [.00] min. 03 [4.05] Ø 8 [Ø 0.7] 5 [.05] Ø 8 [Ø 0.7] 6,7 [0.66] 67,4 [.65] 6,7 [0.66] 67,4 [.65] Type / Side Rotary with djustable Length Roller Lever Type 6C/6 Reversed Side Rotary (Short) Figure 7. Side Rotary C/ imensions PT FP 9,6 [0.77] PT 7 [0.8] 5 [.00] min. 03 [4.05] 67,4 [.65] 6,7 [0.66] Type C/ Reversed Side Rotary with djustable Length Roller Lever Sensing and Internet of Things 5
6 Table 5. Side Rotary Operating Characteristics Catalog Listing ctuation Connector/ Cable Exit Switch Type Circuit iagram ar Charts ifferential Travel Operating Release NGCP*****X** Side Rotary NGCP*****X** NGCP*****X** NGCP*****X** NGCP*****X** NGCP*****X** NGCP*****X** N NGCP*****X** N NGCM*****X** NGCM*****X** NGCM*****X** NGCM*****X** NGCM*****X** NGCM*****X** NGCM*****X** P NGCM*****X** P 5 lue rown lack/ Zb lack lue 3 Zb 4 rown lack lack Zb Zb T 5 8 Ncm [.59 in-lb],5 Ncm [0. in-lb] NGCP*****X** NGCP*****X** NGCP*****X** NGCP*****X** NGCP*****X** NGCP*****X** NGCM*****X** NGCM*****X** NGCM*****X** NGCM*****X** NGCM*****X** NGCM*****X** 6 sensing.honeywell.com rown rown Zb lue lack Zb lue lack lack rown- -lue T - -lack rown- -lue How to read and understand the bar chart information Ncm [.5 in-lb], Ncm [0.9 in-lb] The following example relates to a unit which has a snap action basic and which has a roller pin plunger actuator. Follow the black arrows and the black strip on the chart. The black strip indicates that there is a circuit between the terminals whose numbers are shown on the left and when white there is no circuit. Look at Figures and as examples. ctuator type used for test is the linear Cam travel type (b) shown left. The start point is at the arrow marked (See fig. ). This shows the free position to be 5.3 mm from the vertical center line of the unit. t this stage there is a circuit between the terminals - but no circuit between terminals. The unit can be actuated until it reaches the operating position which is 0,5 mm from the center line a travel distance of 0,5 5,3 = 5, mm from the free position. t this point the circuit arrangement changes no circuit between - but making a circuit between. If, however, the contacts of terminals - weld together and will not separate, a mechanical safety feature will take effect if the switch is travelled past the point from which positive opening is assured,,9 mm. s the switch returns it reaches the release position at 8,9 mm from the center line. The circuit will change back to the original state and the difference between the operating position and the release position gives what is known as the differential travel i.e. 0,5 8,9 =,6 mm. The asterisk (*) indicates the point from which the positive opening is assured.
7 Figure 8. Pin Plunger & imensions Figure 9. Roller Plunger C & S imensions Figure 0. Cross Roller Plunger L & T imensions Ø 8 [Ø 0.3] FP ±0,5 Ø,7 x 4 [Ø 0.5 x 0.6] FP ±0,5 Ø,7 [Ø 0.5] 4 [0.6] FP ±0,5 NGC_ FP 9,8 mm NGC_ FP,4 mm Pin Plunger Figure. Pin Plunger with oot Seal M imensions Ø 6,7 [Ø 0.6],3 [.7] NGC_C FP 30,3 mm NGC_S FP,85 mm Roller Plunger Figure. Panel-Mount PIn Plunger N imensions Ø 8 [Ø 0.3] M x 7,0 [0.8] 36,5 [.44] NGC_L FP 30,3 mm NGC_T FP,85 mm Cross Roller Plunger Figure. Panel-Mount Roller Plunger P imensions Ø,7 x 4 [Ø 0.5 x 0.6] M x 7,0 [0.8] 47,5 [.87] NGC_M Pin Plunger with oot Seal Figure. Panel-Mount Cross Roller Plunger Q imensions M x Ø,7 [Ø 0.5] 7,0 [0.8] 4 [0.6] 47,5 [.87] NGC_N Panel-Mount Pin Plunger Figure 5. Panel-Mount PIn Plunger With oot Seal R imensions Ø 6,7 [Ø 0.6] M x 7,0 [0.8] 47,5 [.87] NGC_P Panel-Mount Roller Plunger Figure 6. Top Roller Lever rm J imensions Ø 6,8 [Ø 0.65] [.6] Operating Position Ø x 5 NGC_Q Panel-Mount Cross Roller Plunger NGC_R Panel-Mount Pin Plunger with oot Seal NGC_J Top Roller Lever rm Sensing and Internet of Things 7
8 Table 6. Plunger Operating Characteristics Catalog Listing Connector/ Cable Exit Switch Type Circuit iagram ar Charts ctuation ifferential Travel Operating Release NGCP*****X /C//L/M/N/P/Q/R/S/T NGCP*****X /C//L/M/N/P/Q/R/S/T NGCP*****X /C//L/M/N/P/Q/R/S/T NGCP*****X /C//L/M/N/P/Q/R/S/T NGCP*****X /C//L/M/N/P/Q/R/S/T lue rown lack/ Zb lack Plunger Head NGCP*****X /C//L/M/N/P/Q/R/S/T NGCP*****X /C//L/M/N/P/Q/R/S/T N NGCP*****X /C//L/M/N/P/Q/R/S/T N NGCM*****X /C//L/M/N/P/Q/R/S/T NGCM*****X /C//L/M/N/P/Q/R/S/T NGCM*****X /C//L/M/N/P/Q/R/S/T NGCM*****X /C//L/M/N/P/Q/R/S/T NGCM*****X /C//L/M/N/P/Q/R/S/T NGCM*****X /C//L/M/N/P/Q/R/S/T NGCM*****X /C//L/M/N/P/Q/R/S/T P NGCP*****X /C//L/M/N/P/Q/R/S/T P 5 lue 3 Zb 4 rown lack lack Zb Zb 0, 4,0 4,9 - - T, mm [0.047 in] N [.47 lb] 3 N [0.67 lb] NGCP*****X /C//L/M/N/P/Q/R/S/T NGCP*****X /C//L/M/N/P/Q/R/S/T NGCP*****X /C//L/M/N/P/Q/R/S/T NGCP*****X /C//L/M/N/P/Q/R/S/T NGCP*****X /C//L/M/N/P/Q/R/S/T NGCP*****X /C//L/M/N/P/Q/R/S/T NGCM*****X /C//L/M/N/P/Q/R/S/T NGCM*****X /C//L/M/N/P/Q/R/S/T NGCM*****X /C//L/M/N/P/Q/R/S/T NGCM*****X /C//L/M/N/P/Q/R/S/T NGCM*****X /C//L/M/N/P/Q/R/S/T rown rown Zb lue lack Zb lue lack 0, 4,0 4,9 - -lack rown- -lue - -lack rown- -lue T,4 mm [0.05 lb] 9,5 N [. lb], N [0.49 lb] NGCM*****X /C//L/M/N/P/Q/R/S/T 8 sensing.honeywell.com
9 Table 7. Top Roller rm Operating Characteristics, Head Type J Catalog Listing ctuation Connector/ Cable Exit Switch Type Circuit iagram ar Charts ifferential Travel Operating Release NGCP*****X J NGCP*****X J NGCP*****X J NGCP*****X J NGCP*****X J lue rown lack/ Zb lack Top Roller rm NGCP*****X J NGCP*****X J N NGCP*****X J N NGCM*****X J NGCM*****X J NGCM*****X J NGCM*****X J NGCM*****X J NGCM*****X J NGCM*****X J P NGCP*****X J P 5 lue 3 Zb 4 rown lack lack Zb Zb 0, 4,0 4,9 - - T 4 mm [0.57 in] 5,5 N [. lb], N [0.7 lb] NGCP*****X J NGCP*****X J NGCP*****X J NGCP*****X J NGCP*****X J rown lue lack Zb 0 - -lack rown- -lue - -lack rown- -lue NGCP*****X J NGCM*****X J NGCM*****X J NGCM*****X J NGCM*****X J NGCM*****X J rown Zb lue lack, 4,0 4,9 T 4,3 mm [0.69 in] 4,5 N [. lb], N [0.7 lb] NGCM*****X J Sensing and Internet of Things 9
10 ITIONL MTERILS The following associated literature is available on the Honeywell web site at sensing.honeywell.com: Product line guide Product part listing/nomenclature tree Product range guide pplication note m WRNING PERSONL INJURY O NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. m WRNING MISUSE OF OCUMENTTION The information presented in this product sheet is for reference only. o not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest uthorized istributor, contact your local sales office. To learn more about Honeywell s products, call or , visit sensing.honeywell.com, or inquiries to info.sc@honeywell.com Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use. Honeywell Sensing and Internet of Things 9680 Old ailes Road Fort Mill, SC 97 honeywell.com EN IL50 GLO October 7 7 Honeywell International Inc. ll rights reserved.
MICRO SWITCH Compact Limit Switches NGC Series Issue 8. Datasheet FEATURES POTENTIAL INDUSTRIAL APPLICATIONS DESCRIPTION DIFFERENTIATION
MICRO SWITCH Compact Limit Switches NGC Series 00409 Issue 8 atasheet FETURES SPT or PT configurable circuitry Snap-action, positive-break contacts Silver alloy and gold-plated contact options UL, CE,
More informationMICRO SWITCH Compact Limit Switches NGC Series Issue 9. Datasheet FEATURES POTENTIAL INDUSTRIAL APPLICATIONS DESCRIPTION DIFFERENTIATION
MICRO SWITCH Compact Limit Switches NGC Series 00409 Issue 9 atasheet FETURES SPT or PT configurable circuitry Snap-action, positive-break contacts Silver alloy and gold-plated contact options UL, CE,
More informationMICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series Issue 2. Datasheet
MICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series DESCRIPTION MICRO SWITCH GKL/R Series switches are a heavy-duty key operated solenoid safety interlock switch incorporating a key trapping mechanism.
More informationVL Series. General Purpose Compact Limit Switches. Sensing and Control
FEATURES Gold plated silver contacts Compact design for small mounting space. Special design for easy wiring with ample wiring space Two-circuit double-break Diecast base and plastic cover Standard mounting
More informationonlinecomponents.com VL Series General Purpose Compact Limit Switches Sensing and Control
FEATURES Gold plated silver contacts Compact design for small mounting space. Special design for easy wiring with ample wiring space Two-circuit double-break Diecast base and plastic cover Standard mounting
More informationMicrocontroller Unit (MCU) LCD Hour Meters/Counters. LM Series. Datasheet
Microcontroller Unit (MCU) LCD Hour Meters/Counters LM Series Datasheet LM Series Microcontroller Unit (MCU) LCD Hour Meters/Counters Honeywell s MCU (microcontroller unit) LCD (liquid crystal display)
More informationEQUIVALENT BASIC CIRCUIT
FEATURES Reliable semiconductor technology Calibrated and temperature compensated Rugged, stainless steel package NEMA 4 design Small size Absolute, gage, sealed gage, vacuum gage pressures 0 psi to 3
More informationLoad Accessories. Test & Measurement Sensors DESCRIPTION TONGUE SHACKLE FEATURES PULL PLATE FEATURES YOKE SHACKLE FEATURES LOAD BUTTON FEATURES
Test & Measurement Sensors DESCRIPTION Honeywell provides a wide range of accessories for our test and measurement sensor products, which are designed to meet additional requirements for most customer
More informationMICRO SWITCH Weather-Sealed, Explosion-Proof Switches. CX Series. Datasheet
MICRO SWITCH Weather-Sealed, Explosion-Proof Switches CX Series Datasheet MICRO SWITCH CX Series Weather-Sealed, Explosion-Proof Switches MICRO SWITCH CX switches are built especially for outdoor use in
More informationInstallation and Service Instructions for EX Series Explosion-proof Switches
Installation and Service Instructions for EX Series Explosion-proof Switches ISSUE 4 50009662 WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application
More informationMICRO SWITCH Heavy-Duty Limit Switch (Stainless Steel) HDLS LS2 Series
MICRO SWITCH Heavy-Duty Limit Switch (Stainless Steel) HDLS LS2 Series DESCRIPTION When the application requires an industrial grade limit switch where wet, dust, or corrosive environments may be present,
More informationCompact plastic limit switches with positive opening mechanism
Compact limit switches with positive opening mechanism LJK-N Series Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N
More informationInstallation Instructions for the ISSUE 2 Explosion-proof Limit Switches LSX Series PK 81181
Installation Instructions for the ISSUE 2 Explosion-proof Limit Switches LSX Series PK 81181 WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices, or in any other application
More informationCompact plastic limit switches with positive opening mechanism
Compact limit switches with positive opening mechanism LJK-NSeries Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N conforms
More informationOperation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)
Safety-door Switch D4BS The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment CSM_D4BS_DS_E_6_1
More informationSpeed Sensors Line Guide
Speed Sensors Line Guide Speed and reliability. Honeywell S&C offers electronic speed and position sensors designed for enhanced reliability and an extended life. Honeywell uses multiple technologies to
More informationPosition switches FD series
Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever
More informationPrewired position switches FF series
2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable
More informationFL series position switches
FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable
More informationHoneywell Pressure Switches. Datasheet. High Pressure: HP Series, HE Series Factory set 150 psi to 4500 psi [10,34 bar to 310,26 bar]
oneywell Switches igh : P Series, E Series actory set 150 psi to 4500 psi [10,34 bar to 310,26 bar] Low : LP Series, LE Series actory set or field adjustable 3.5 psi to 150 psi [0,24 bar to 10,34 bar]
More informationDistributed by: www.jameco.com -800-83-22 The content and copyrights of the attached material are the property of its owner. 0-5 psi Through 0-300 psi FEATURES Low Cost Sensor Element Internal Temperature
More informationPosition switches FC series
A Position switches FC series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere 6 adjustable lever safety adjustable lever
More informationD4BS CSM_D4BS_DS_E_8_4
Safety-door Switch CSM DS_E_8_4 The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment
More informationED SERIES SAFETY LIMIT SWITCH
Description The ED series safety limit switches conform to EN 547 and have been developed to provide a range of options including plastic cases in various sizes, a choice of snap acting, slow break/make
More informationLJASeries. Limit Switches with Positive Opening Mechanism
Limit Switches with Positive Opening Mechanism LJASeries Snap action limit switches with positive opening mechanism enables general industrial machines to comply with EC directives and to acquire CE marking.
More informationPrewired position switches FF series
2 Prewired position switches FF series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45 46
More informationSafety Limit Switch
Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_4_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit
More information2NC (slow-action) Direct. Model. opening
Small Safety Limit Switch D4F CSM_D4F_DS_E_5_2 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The
More informationLimit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66
Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66
More informationSafety Limit Switch
Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit
More informationPresentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508
Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:
More informationLimit Switches with Positive Opening Mechanism
Limit Switches with Positive Opening Mechanism LJA Series Positive opening mechanism Snap action limit switches with positive opening mechanism enables general industrial machines to comply with EC directives
More informationPK Installation Instructions for the 2CPS Series Cable Pull Switch Without Broken Cable Detection ISSUE 3. Sensing and Control
ISSUE 3 Installation Instructions for the 2PS Series able Pull Switch Without roken able Detection PK 80169 WRNING IF USED IN PPLITIONS ONERNING HUMN SFETY Only use N direct opening ( positive opening
More informationD2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch
Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive
More information2NC (slow-action) Direct. Model. opening
Small Safety Limit Switch CSM DS_E_3_1 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The world's
More informationMICRO SWITCH Global Limit Switches GLA Series Issue 1. Datasheet FEATURES DESCRIPTION VALUE TO CUSTOMERS POTENTIAL APPLICATIONS
MICRO SWITCH Global Limit Switches GLA Series DESCRIPTION Honeywell s MICRO SWITCH GLA Limit Switch Series is designed to global EN50041 standards and well suited for worldwide applications. The modular
More informationPosition switches FR series
Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket
More informationLimit Switch - Prewired Type Metal Body
Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation
More informationLimit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.
Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with
More information10260S Series Actuators Auto-Manual Switch Replacement Instruction
10260S Series Actuators Auto-Manual Switch Replacement Instruction Document Number Form: 62-86-33-26 Effective: 06/01 Supersedes: none Overview These instructions apply to the following kit: 51500581-501
More informationA165E CSM_A165E_DS_E_11_2
Emergency Stop Switch (16-dia.) CSM DS_E_11_2 Separate Construction with Minimal Depth Direct opening mechanism to open contacts in emergencies, such as when they are welded. Conforms to EN 6947-5-5. Includes
More informationMiniaturized limit switches
Miniaturized limit switches Selection diagram Actuators 04 0 06 Thermoplastic Bodies M3 Contact blocks NONC 1NO+1NC snap action Cable entry With screw 290 GENERAL CATALOGUE miniaturized limit switches
More informationEN REV.
Honeywell Series 6100 Pneumatically Operated Spring Opposed Diaphragm Actuators 70-17-10-05 EN REV. 2 09/2014 Page 1 of 7 Specification Series 6100 Pneumatically Operated Spring Opposed Diaphragm Actuators
More informationProduct Range Guide MICRO SWITCH Hazardous Area Switches
Product Range Guide MICRO SWITCH Hazardous rea Switches Rugged. Reliable. Ready for use. Honeywell has a complete family of hazardous area limit switches tailored to exact specifications for superior performance,
More informationCSM_D4N-_R_DS_E_6_1
Pull-reset Safety Limit Switch D4N-@R CSM_D4N-_R_DS_E_6_1 A Series of Pull-reset s Now Available Note: Contact your sales representative for details on models with safety standard certification. Lineup
More information10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512
10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits 51404974-501 through -512 Document Number Form: 62-86-33-16D Effective: 3-1-01 Supersedes: 11-00 Summary Retrofitting your 10260 actuator from
More informationHL (AZH) LIMIT SWITCHES
COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount
More informationD2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.
Highly reliable iniature Basic Switch in spite of its Ultra-low Load action Twin crossbar contact employed for exceptionally high contact reliability. Unique internal mechanism that ensures high contact
More informationCompact Limit Switches
Compact AEMG Series Compact Die-cast metal housings 3-meter cable on all units N.O. and N.C. contact on all units Compact size with standard 5 mm hole spacing Wide offering of head actuators Epoxy resin-filled
More informationHercuLine 2000 Series Gear Kit Replacement Instructions
HercuLine 2000 Series Gear Kit Replacement Instructions 51452443-501 Document Information Form: 62-86-33-35 Effective: 5/04 Supersedes: None Summary This kit contains all the gears, idler shafts and hardware
More informationPosition switches FR series
Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33
More informationApplications Mill Mill Mill Mill. 9007T Convertible sequence. L100 Fixed sequence. Extra heavy duty contact ratings. Extra heavy duty contact ratings
Selection Guide Severe Duty Mill and Foundry Switches pplications Mill Mill Mill Mill Design 9007T Convertible sequence L0 Fixed sequence L14 Single Cable Pulls Fixed sequence L525 elt Conveyor Fixed sequence
More informationOrdering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31
Snap Action Switch Subminiature Snap Action Switch Switches 3 A loads (general-purpose), 1 A loads (low force general-purpose) and 0.1 A loads(microvoltage/ microcurrent) Long life span assured by high-precision
More informationD4NH CSM_D4NH_DS_E_7_1
Safety-door Hinge Switch D4NH CSM_D4NH_DS_E_7_1 Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Lineup includes three contact models with 2NC/1NO
More informationLK Position Switches TECHNICAL DATASHEET.
LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions
More informationD4GS-N CSM_D4GS-N_DS_E_7_2
Slim Safety Door Switch D4GS-N CSM_D4GS-N_DS_E_7_2 Slim Safety Door Switches with IP67 Rating Slim design with a width of only 17 mm (three-contact models). Reversible design allowing either front or rear
More informationMultiple Limit Switch
Multiple Limit Switch CSM DS_E_1_1 A New Monoblock Multiple Limit Switch Incorporating a ead Box with a Tough ead and Ensuring igh Sealing Performance and a Mechanical Durability of 5,000,000 Operations
More informationManual Reset Limit Switch
Manual Reset Limit Switch A Series of Pull-reset Models Available Ideal for elevators (EN81), escalators (EN115), and conveyors. Positive opening mechanism insulation approved by TÜV and BIA. and double
More informationS840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en
Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break
More informationED SERIES SAFETY LIMIT SWITCH Description
Description The ED series safety limit switches conform to EN 50047 and have been developed to provide a range of options including plastic cases in various sizes, a choice of snap acting, slow break/make
More informationRatings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator
Miniature Limit Switch CSM DS_E_3_3 Many Models Including Roller Lever Switches are Only -mm Thick with Connector New center roller lever models that enable ganged mounting of up to 6 Switches. Cable connectors
More informationLimit Switches - Limit Type (PS21L) Metal Body IP66
Limit Switches - Limit Type (PS21L) Metal Body IP66 High mechanical resistance Degree of protection IP66 Zinc alloy (Zamack) or aluminium body Positive Opening Operation Minimum Actuation Force/Torque
More informationBasic, Toggle, and Rocker Switches Product Range Guide
Basic, Toggle, and Rocker Switches Product Range Guide For innovation that s well apart, there s only Honeywell With more than 50,000 products ranging from snap-action, limit, toggle, and pressure switches
More informationD4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information
Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding
More informationDIN Track Terminal Blocks with Screw Terminals XW5T
New Product DIN Track Terminal Blocks with Screw Terminals XW5T Global-standard DIN Terminal Blocks for Control Panels Wires held with screws. Compatible with a wide range of wire sizes from 0.14 to 185
More informationSafety switches for hinged doors
4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationA22LK CSM_A22LK_DS_E_6_2
Guard Lock Safety Key CSM DS_E_6_2 The guard lock prevents accidental mode changes. for secure equipment activation during maintenance The guard lock of the Operation Unit prevents incorrect operation.
More informationMetal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.
Limit switches pre-wired 3mm & 35mm Metal & plastic casings Limit switches Description Plastic are made of reinforced UL-VO thermoplastic fiberglass, offering double insulation and protection
More informationInstallation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator
www..c Installation & Operation Manual Electrak 100 Series / Electromechanical Linear Actuator Thomson has many years of experience designing and manufacturing linear actuators for a wide variety of applications
More informationDIN Track Terminal Blocks with Screw Terminals
New Product DIN Track Terminal Blocks with Screw Terminals XW5T Global-standard DIN Terminal Blocks for Control Panels Wires held with screws. Compatible with a wide range of wire sizes with a nominal
More informationDIN Track Terminal Blocks with Screw Terminals XW5T
New Product DIN Track Terminal Blocks with Screw Terminals XW5T Global-standard DIN Terminal Blocks for Control Panels Wires held with screws. Compatible with a wide range of wire sizes with a nominal
More informationD4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment
Safety-door Hinge Switch CSM DS_E_4_1 Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Note: Contact your sales representative for details on models
More informationSwitches with manual reset
Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever
More informationD4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening
Safety Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking H Contacts opened by positive opening mechanism (NC contacts only) H Double insulation makes ground terminal
More informationG3PE-Single-phase. Solid State Relays for Heaters
Solid State Relays for Heaters Single-phase CSM_Single-phase_DS_E Compact, Slim-profile SSRs with Heat Sinks. s with No Zero Cross for a Wide Range of Applications. RoHS compliant. s also available with
More informationTechnical Product Sheet
18 kg Ejection Mitigation Featureless Headform P/N ATD-7304 Technical Product Sheet On December 2, 2009 NHTSA submitted a Notice of Proposed Rulemaking (NPRM) on Ejection Mitigation (docket NHTSA-2009-0183).
More informationLimit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark
Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Features positive opening mechanism (NC contacts only) that opens contacts, thus preventing faulty
More informationSOLDER SHORT SOLDER SCREW
32 Honeywell MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945. CUT-A-WAY V3 MINIATURE BASIC SWITCH GENERAL INFORMATION V3 miniature basic switches feature high electrical capacity
More information11280A HercuLine Series Actuator. Specification. Non-Contact Position Sensing and Variable Speed Motor Control. Overview. Features. Actuator Operation
11280A HercuLine Series Actuator Non-Contact Position Sensing and Variable Speed Motor Control 10/00 Page 1 of 12 Specification Overview To operate with maximum efficiency and improve process uptime, state-of-the-art
More informationD2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend
ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject
More informationSL1Series. Compact Horizontal Limit Switches
Compact Horizontal Limit Switches SL1Series Mechanical life of 0 million operations. Robust long-life and maintenance-free compact horizontal-type limit switches with IP67 seal. Mechanical life exceeds
More informationl Snap-Action Switches
Connect - Contact - Control 2 Brochure l Snap-Action Switches Snap-action switches I Page 2 Page 3 I Snap-action switches Double Safety A sky diver's life depends on his equipment. In case of emergency
More informationM3 Series Product. Class 0 - protection against electric shock relies upon basic insulation
Product Changeover circuit with rating 16A ong life snap action contacts mechanism Self-cleaning contact action Variety of actuators Screw, front screw or quick connect (faston) terminals dimensions according
More informationPRODUCT SPECIFICATION. Foot Switches. Series.
PRODUCT SPECIFICATION Foot 46 Series www.wernerelektrik.com Foot Switch Structures...1 Technical Data...2 Model Number Structure - Foot...3 Dimensions...4 Precautions... Foot WERNERS are Rigorous and tough.
More informationInternational, LLC. HMS/HLS/HNS Series Heavy Duty Limit Switches. Specifications. Features. Electrical Ratings HNS HLS HMS. Non-plug-in.
HMS/HLS/HNS Series Heavy Duty Limit Switches Features Heavy duty zinc die cast body Conform to EN 6097-5-1, IEC 6097-5-1, UL508, NEMA250, CSA22.2 Standards Wide range of actuator available High repeatability
More informationD2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend
ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject
More informationD4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K
Guard Lock Safety-door Switch D4BL CSM_D4BL_DS_E_10_1 Die-cast aluminum body Key holding force of 700 N Auxiliary release key ensures easy maintenance and unlocks the door in the case of a power failure.
More informationDouble insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators
Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)
More informationLimit Switches - Limit Type Plastic Body IP65
Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum
More information(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet
Small Sealed Switch D4E-N CSM_D4E-_N_DS_E_6_ Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth
More informationLimit Switches - Limit Type Plastic Body IP65
Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum
More informationSafety rope switch without reset for simple stop
afety rope switch without reset for simple stop election diagram FP 4-M2 FD 4-M2 FL 4-M2 FR 4-M2 FM 4-M2 FX 4-M2 FZ 4-M2 ACTUATOR 9 ACTUATOR 9 0 CONTACT BLOCK 1 9 21 1NO+ FP FD FL FC 33 34 CONDUIT ENTRIE
More informationSafety rope switches with reset for emergency stop
Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available
More informationHL (AZH) Limit Switches
COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Wide selections of actuators, terminals and bodies to meet any application Excellent environmental resistance Die casting caseiec IP67 Plastic caseiec
More informationS826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en
2 Snap-action switches S826, S26 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en 2 Snap-action switches S826 Series Dual changeover switches with positive
More informationTraffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7
Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7 1 Table of Contents Dimensions... 3 Technical Specifications... 4 Communication... 5 Programming... 6 Data Collection and
More informationSafety rope switch with reset for emergency stop
Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With
More informationLimit Switches - Limit Type (PS31L) Plastic Body IP65
Limit Switches - Limit Type (PSL) Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque
More informationMiniature Pre-Leaded Vertical Enclosed Switches
Miniature Pre-Leaded Vertical Enclosed Switches 14CE Series Miniature enclosed switches with outstanding harsh environment resistance, ideal for compact machinery and equipment. Easy mounting by tightening
More informationInstallation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models
www..com Installation & Operation Manual Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models INTRODUCTION Thomson has many years of experience
More information