1 Integra Operation and Service Manual

2 1 Integra

3 Table of contents Indications For Use Contraindications Table of Symbols General Warnings Battery Warnings Battery Charger Warnings Overview Preparing to Use the System Operating the System Battery Charge Status and Low Battery Notification Recharging the Battery Maintenance and Cleaning Troubleshooting Specifications Electromagnetic Compatibility (EMC) Integra Surgical Headlight Systems Ordering Information Replacement Parts & Accessories Ordering Information Repair and Return Limited Warranty

4 Integra CAUTION: FEDERAL (USA) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN Indications for use The Integra is designed to provide illumination to aid visualization during minor surgical, diagnostic, or therapeutic procedures. This device is intended to be used by professional users. Contraindications The Integra is contraindicated for use in neonate transillumination, ophthalmic procedures, or with photosensitive patients or patients who have received photosensitizing agents (hematoporphyrin derivatives) within three months. 3

5 Table of Symbols Do not dispose No naked flames Meets requirements of the Medical Device Directive Recycle symbol Listed by ETL UN approved container Eligible for Call2Recycle Program Recycling symbol (Taiwan) REF Part Number Restriction of Hazardous Substances (China) 5 Year safe use period Serial Number Refer to Manual In this manual, this symbol and Warning indicate conditions or practices that could lead to illness or injury In this manual, this symbol and Caution indicate conditions or practices that could damage the equipment or other property Caution: Federal (USA) law restricts this device to sale by or on the order of a physician Temperature limitations EU Authorized Representative Humidity limitations Manufacturer Atmospheric pressure 4

6 Integra General Warnings The user should carefully study the Operation and Service Manual before using the in the clinical environment. Instructions should be followed, with special attention given to warnings, controls, and user specifications. The Manual should be available to appropriate personnel. This Manual contains information about the proper procedures for preparing this product for its use and care. Before every procedure, carefully inspect the LED Surgical Headlight System to ensure it has been properly maintained, cleaned, and is fully functional. DO NOT use if an inspection reveals any damage such as case damage or loose connectors. Follow the instructions of other manufacturer s equipment when used in conjunction with this product. To reduce the risk of fire and electric shock, do not expose electrical equipment to moisture. When cleaning, do not immerse any electrical device in liquid. Do not use or store liquids on or above the LED Surgical Headlight System. SAFETY PRECAUTIONS MUST ALWAYS BE EXERCISED WHEN USING ELECTRICAL EQUIPMENT TO PREVENT OPERATOR/PATIENT SHOCK, FIRE HAZARD OR EQUIPMENT DAMAGE. Electric shock hazard. If unit is not functioning properly, DO NOT OPEN. Please refer to the Repair and Return section of this Manual. The must be used with the recommended Integra battery or with recommended Integra power cords with plugs inserted into properly grounded AC power outlets. The should never be used in ocular surgery or in a surgical procedure requiring direct illumination of the eye. Only use enough light to ensure good visualization, and avoid prolonged close stationary illumination of tissue to reduce the risk of thermal injury to tissue. When the is not in use, turn off the power. Explosion Hazard. Do not use the LED Surgical Headlight System in an oxygen rich environment or in the presence of flammable anesthetics, liquids, vapors, gases, or dusts. Keep cooling vent and fans free of obstructions. To ensure patient and operator safety and optimal product performance, use only accessories and supplies recommended for or supplied with the system, and use them according to the directions for use. The Headlight System complies with applicable domestic and international standards for electromagnetic interference. As a precaution, avoid using the device in close proximity to other equipment. Do not directly connect or short-circuit the positive (+) and negative (-) battery terminals. To avoid short circuits, keep battery terminals away from metal objects. Do not expose the battery to temperatures higher than 49C/120F. You must charge the batteries for four (4) hours or until completely charged before using the battery power option. A dead battery may result if the batteries are left uncharged or unused for a long period of time. If the will be unused for several months or longer, remove the battery from the battery holster prior to storing the system. The produces high intensity light. Use care not to point the Headlight directly at the eye while in use. 5

7 Battery Warnings Battery Charger Warnings Defective batteries can damage the Surgical Headlight System. If the battery shows any signs of damage, leakage, or cracking, it must be replaced immediately and only with an Integra battery recommended for or supplied with the system. Improper disposal of batteries may create an explosion or contamination hazard. Never dispose of batteries in refuse containers. Do not dispose of the battery in fire. Always recycle batteries according to local regulations. Improper handling of the battery can lead to heat generation, smoke, bursting, or fire. Do not remove the label from the battery. Do not immerse the battery in water or other liquids. Do not disassemble, modify, or solder the battery. Do not directly connect or short-circuit the positive (+) and negative (-) battery terminals. To avoid short circuits, keep battery terminals away from metal objects. Do not expose the battery to temperatures higher than 49C/120F. Do not expose the charger or power supply to water or liquids. The case is not sealed. Do not open the charger or power supply case. No user serviceable parts are inside. Do not cover the fan exhaust or obstruct the airflow, this will cause overheating. Use only the manufacturer s recommended power supply, charger, batteries and power cords. Store the charger in a cool spot, away from external heat sources. If replacement is necessary, replace only with approved power cord. Caution During recharging, the charger may become warm. No modification of this equipment is allowed. This device should be used in environments that meet the operating environmental conditions in the specification section of this manual. You must charge the batteries for four (4) hours or until completely charged, before using the battery power option. A dead battery may result if the batteries are left uncharged or unused for a long period of time. If the will be unused for several months or longer, remove the battery from the battery holster prior to storing the system. 6

8 Integra Overview 1 The Integra is a self-contained headlight system that can be operated using either a battery or a direct power supply. Using a battery pack gives the surgeon complete mobility, allowing unrestricted movement in and around the operating suite. The direct power supply option can be used as a primary power source for unlimited operating time, or as a back-up to the battery system. The Integra utilizes an LED light source with an active cooling system. A thermostaticallycontrolled cooling fan draws air at a very low flow rate through ports on the side and back of the headlight module, quietly cooling the LED. The air is drawn through a system of ducts and is gently exhausted behind the surgeon. The major components of the Headlight itself are shown in Figure 1 and described below. 1 Headband Suspension Linkage Controller Headlight Module Duct System Headlight Cable Headlight Module Controller Duct System Contains the LED light source, a thermostat for monitoring LED temperature, an iris for controlling spot size, and optical elements to project a homogeneous spot of light to the surgical field. Regulates power to the LED from either Battery or Direct DC Power Supply, adjusts the cooling fan according to LED temperature and houses a four position rotary switch to control LED intensity. Serves as a conduit for airflow from the headlight module to the cooling fan. Headband Suspension Linkage Headlight Cable Offers versatile size adjustment using two knobs (top and back) and incorporates a replaceable pad set. Connects the headlight module to the headband and allows for positioning of the headlight module Connects the Battery or Direct DC Power Supply to the Controller. 7

9 90520 LED Headlight w/batteries and AC/DC Power Supply 2 The deluxe model includes components for both the portable battery operation as well as AC/DC Power operation. LED Headlight with Cable 2 Batteries Battery Holster Battery Charger Base 60W Power Supply AC Mains Power Cords 30W Power Supply 20 DC Power Extension Cord D LED Headlight with AC/DC Power Only 3 The AC/DC Power Only model comes equipped with these components: LED Headlight with Cable AC Mains Power Cord 30W Power Supply 20 DC Power Extension Cord 3 8

10 Integra Preparing to Use the System- With Battery Option 4 1. Clip the Battery Holster in a comfortable location Insert and fully seat the Battery into the Battery Holster. For proper battery orientation, align the battery so that the 5-pin connector in the holster mates with the 5 slots on the battery. The battery label will be visible through the opening in the outside surface of the holster, as shown in Figure Approximate battery continuous run time is dependent on switch setting, level of charge and calibration state of battery. On a fully charged battery, approximate run times are: High Switch setting is approximately 2 hours plus low battery notification cycle Medium Switch setting is approximately 2 1/2 hours plus low battery notification cycle Low Switch setting is approximately 3 hours plus low battery notification cycle With AC/DC Power Option 1. Connect the AC/DC Power Supply to the supplied AC Mains power cord. Plug the AC Mains power cord into any standard 100 VAC to 240 VAC Hz outlet. 2. Connect the output cord of the AC/DC Power Supply to the Extension DC Power Cord. Align the connectors and push firmly until they are firmly seated. The connector pins are not keyed and will accept either orientation. 9

11 Preparing to Use the System- With Battery Option Place the LED Headlight on the head, with the light module located between the eyes (Figure 5). Optimal coaxial (shadow-free) positioning is achieved when a line drawn between the pupils bisects the headlight module lens. 2. Adjust the headband for optimal comfort by rotating the adjustment knobs on the top and back of the headband. 3. Connect the Headlight s power cable to the power source. For the Portable Battery Option, this is the battery holster (Figure 7). For the Direct Power Option, this is the 20 DC Power Extension cord from the Direct Power Supply (Figure 8). The connectors are not keyed and will accept either orientation. 4. To illuminate the LED headlight, turn the rotary switch located on the back of the headlight to the desired intensity (Figure 6). The available settings are Low, Medium, and High Battery power #90500 LED Headlight AC/DC power #90500 LED Headlight #90522 Battery # DC Power Cord # AC/DC Power Supply Connector #90521 Holster 10

12 Integra Battery Charge Status and Low Battery Notification 9 1. The Battery utilizes a 5-bar LCD fuel gauge to indicate its charge 9 status (Figure 9): 5 bars displayed 81% - 100% charged 4 bars 61% - 80% 3 bars 41% - 60% 2 bars 21% - 40% 1 bar 1% - 20% No bars Fully discharged 2. An audible notification in the form of a three-tone cycle will sound when the battery has fifteen minutes of charge remaining. The notification will repeat more frequently as the battery approaches the fully-discharged state. 15 minutes remaining 1 audible notification cycle 12 minutes 1 cycle 9 minutes 2 cycles 6 minutes 3 cycles 3 minutes Notification cycle repeats until battery is fully discharged 3. Lowering the Headlight intensity setting will extend the duration of the charge. If the intensity setting is lowered after the low battery notification sounds, the system will be reset and will reflect the longer remaining battery charge. 4. Approximate battery continuous run time is dependent on switch setting, level of charge and calibration state of battery. On a fully charged battery, approximate run times are: High Switch setting is approximately 2 hours plus low battery notification cycle Medium Switch setting is approximately 2 1/2 hours plus low battery notification cycle Low Switch setting is approximately 3 hours plus low battery notification cycle 11

13 Recharging the Battery Place the Battery Charger on a flat, level surface away from 10 sources of heat and moisture. 2. Connect the Battery Charger base to the 60W power supply. Insert the supplied AC Mains cord into the power supply. Plug the AC Mains cord into any standard 100 VAC to 240 VAC Hz outlet. 3. Place the battery into the Charger s battery bay, ensuring that the 5-pin connector is fully seated (Figure 10). 4. The Battery Charger will automatically begin charging. The LEDs in the charger status window will provide charging status information: Green flashing Green solid Red solid Battery charging Battery fully charged Error replace battery 5. A completely discharged battery should become fully charged in approximately two and one-half (2.5) hours. 6. Each fully charged battery is designed to operate for approximately 2 hours plus low battery warning cycle on the high switch setting. 12

14 Integra Maintenance and Cleaning Maintenance The Integra requires no routine maintenance. For servicing and/or repair, refer to the Repair and Return section of this manual. Cleaning 1. Unplug the unit prior to cleaning. 2. Wipe the surfaces of the Headlight and cables with a cloth slightly dampened with a mild detergent, 70% isopropyl alcohol, mild soap and water or solution of 10% bleach and water. Use only 70% isopropyl alcohol to clean the Headlight lens. Excess solution entering the headlight assembly could damage internal components. Use caution to ensure cloth is not saturated with solution. 3. Do not operate the system until the Headlight is thoroughly dry. Caution Do not immerse any component of the in cleaning solution. Caution Do not sterilize the. 13

15 Troubleshooting Trouble Area Possible Cause Corrective Action Headlight will not switch on Brightness of spot decreases during use Brightness of spot is diminished and / or the spot appears fuzzy Fully charged battery operates headlight for less than 2 hours Cooling fan is making a whirring or clicking sound Power cord connections may not be effective Temperature of LED may have increased due to blockage of airflow Lens may be contaminated Battery may be losing charge capacity Fan may have been damaged after dropping headlight Detach and firmly seat to assure complete connection Turn off the headlight, check and remove any obstructions from the headlight module and controller fan vents. a Clean lens with 70% Isopropyl Alcohol Replace battery Return to Integra for service a The operating temperature of the LED is continuously monitored and the fan speed is adjusted to maintain proper LED operating temperatures. In the event of a malfunction in the cooling system or blockage of airflow, the power in the LED will be reduced to the low setting. If the temperature of the LED continues to rise, the intensity of the headlight will default to a setting less than the low setting of the headlight. This serves to communicate the overheating condition while maintaining some level of illumination until an alternate light source can be employed. 14

16 Integra Electromagnetic Compatibility Portable LED Headlight Type Wattage Lamp Life Color Temperature Spot Size Range Power Input Battery Power Kit Type Lithium Ion, 4 cell pack Capacity Wh Voltage Ah Electrical Safety IEC Battery Charger, Single Bay Classifications Input Output Direct Power Kit Classifications Power Input Power Output AC Power Leakage Electromagnetic Compatibility Power Cords Type Appliance End Outlet End Environment LED 13 Watts >25,000 hours 5,250 K 25mm to 125mm at 16 in (~40cm) working distance 9-15 VDC US/FDA, Canada, Australia, EU: Class II, Double Insulated VAC, Hz, 1.5 A 24 VDC, 2.7 A US/FDA, Canada, Australia, EU: Class II, Double Insulated VAC, Hz, 1.0 A 15 VDC, 2.0 A 264VAC, 60Hz EN55022/55024/61000 Class II, A, Double Insulated, Detachable IEC C17 Country specific for US, UK, AU, EU Operating Temperature 6 C to 40 C (43 F to 104 F). Above 5,000 ft (1,524 m) elevation, the maximum operating temperature is 32 C (90 F). Operating Humidity 10% to 95% Relative Humidity, non-condensing Storage/Transport Temperature -20 C to 49 C (-4 F to 120 F) Storage/Transport Humidity 30% to 80% Relative Humidity, non-condensing Mode of Operation Continuous Ingress Protection IP20 Pressure Operating hPa / Storage hPa 15

17 Electromagnetic Compatibility (EMC) User Information Table 201 Guidance and Manufacturer s Declaration Emissions All Equipment and Systems The Integra is intended for use in the electromagnetic environment specified below. The customer or user should insure that it is used in such an environment. Emissions Test Compliance Electromagnetic Enforcement -- Guidance RF Emissions CISPR 11 Group 1 The Integra uses RF energy only for its internal function. Therefore, RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF Emissions CISPR 11 Harmonics IEC Voltage fluctuations/flicker emissions IEC Class B Radiated and Conducted Emissions Class A Complies The Integra is suitable for use in all establishments including domestic and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes. Table 202 Guidance and Manufacturer s Declaration Immunity All Equipment and Systems The Integra is intended for use in the electromagnetic environment specified below. The customer or user should insure that it is used in such an environment. Immunity Test IEC Test Level Electrostatic Discharge (ESD) IEC Electrical Fast Transient/burst IEC Surge IEC For Direct Power (AC) Operation: Voltage dips, short interruptions and voltage variations on power supply input lines IEC Power Frequency 50/60 Hz Magnetic Field IEC ± 6 kv contact ± 8 kv air ± 2 kv mains ± 1 kv I/O ±1 kv Differential ± 2 kv Common >95% Dip for 0.5 Cycle 60% Dip for 5 Cycles 30% Dip for 25 Cycles >95% Dip for 5 sec Compliance Level ± 6 kv contact ± 8 kv air ± 2 kv mains Not applicable ±1 kv Differential ± 2 kv Common >95% Dip for 0.5 Cycle 60% Dip for 5 Cycles 30% Dip for 25 Cycles >95% Dip for 5 sec Electromagnetic Environment -- Guidance Floors should be wood, concrete, or ceramic tile. If floors are synthetic, the relative humidity should be at least 30% Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. If the user requires continued operation during power mains interruptions, it is recommended that the unit be powered from an uninterruptable power supply or battery accessory. 3 A/m 3 A/m Power frequency magnetic fields should be that of a typical commercial or hospital environment. 16

18 Integra Electromagnetic Compatibility (continued) Table 204 Guidance and Manufacturer s Declaration Electromagnetic Immunity The Integra is intended for use in the electromagnetic environment specified below. The customer or user should insure that it is used in such an environment. Immunity Test IEC Test Level Conducted RF IEC Radiated RF IEC Vrms from 150 khz to 80 Mhz 3 Vrms from 80 MHz to 2.5GHz Compliance Level V1 = 3 Vrms E1 = 3V/m Electromagnetic Environment Guidance Portable and mobile RF communications equipment should be no closer to any part of the LED Surgical Headlamp System, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter (distances 1.17 and 2.33). Recommended separation distance: d = [3.5/V1] P d = [3.5/E1] P 80 MHz to 800 MHz d = [3.5/E1] P 800 MHz to 2.5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic survey a, should be less than the compliance level in each frequency range b. NOTE 1. At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2. These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the system under test is used exceeds the applicable RF compliance level above, the system under test should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the system under test. b Over the frequency range 150 khz to 80 MHz, field strengths should be less than [V1]V/m 17

19 Integra Surgical Headlight Systems Ordering Information REF # Description Headlight Battery Kit AC/DC Power Kit Integra with Batteries and AC/DC Power 90520US 90520EU 90520UK 90520AU LED Headlight w/batteries & AC/DC Power Supply - US LED Headlight w/batteries & AC/DC Power Supply - EU LED Headlight w/batteries & AC/DC Power Supply - UK LED Headlight w/batteries & AC/DC Power Supply - AU 90520D Integra with AC/DC Power Only 90520DUS 90520DEU 90520DUK 90520DAU LED Headlight with AC/DC Power Supply Only - US LED Headlight with AC/DC Power Supply Only - EU LED Headlight with AC/DC Power Supply Only - UK LED Headlight with AC/DC Power Supply Only - AU US 90550US EU 90550EU UK 90550UK AU 90550AU N/A 90550US N/A 90550EU N/A 90550UK N/A 90550AU 18

20 Integra Replacement Parts & Accessories Ordering Information 90530US Battery Kit - US Contains Holster, Charger, W Charger Power Supply, Batteries (QTY.2), 90590US Power Cord 90530EU Battery Kit - EU Contains Holster, Charger, W Charger Power Supply, Batteries (QTY. 2), 90590EU Power Cord 90530UK Battery Kit - UK Contains Holster, Charger, W Charger Power Supply, Batteries (QTY. 2),, 90590UK Power Cord 90530AU Battery Kit - AU Contains Holster, Charger, W Charger Power Supply, Batteries (QTY. 2),, 90590AU Power Cord 90550US ac/dc Power Kit - US Contains AC/DC 30W Power Supply, DC Power Cord, 90590US Power Cord 90550EU ac/dc Power Kit - EU Contains AC/DC 30W Power Supply, DC Power Cord, 90590EU Power Cord 90550UK ac/dc Power Kit - UK Contains AC/DC 30W Power Supply, DC Power Cord, 90590UK Power Cord 90550AU ac/dc Power Kit - AU Contains AC/DC 30W Power Supply, DC Power Cord, 90590AU Power Cord LED Headlight Only LED Headband Replacement Pads (10/Box) Battery Holster Lithium Ion Batteries-QTY DC Power Cord ac/dc 30W Power Supply Battery Charger, Single Bay Battery Charger 60W Power Supply 90590US ac Mains Power Cord - US 90590EU ac Mains Power Cord - EU 90590UK ac Mains Power Cord - UK 90590AU ac Mains Power Cord - AU 19

21 Repair and Return Returning Device for Repair This device must be clean and decontaminated prior to return to Integra. Integra reserves the right to return any unrepaired equipment that is contaminated with blood or other organic material. Warranty Service and Repair To obtain service under warranty or return product for repair, the customer should contact its local Integra representative or call Integra Customer Service at , or US and Canada Toll Free: 1-(800) Limited Warranty Integra warrants that the shall be free from defects in material and workmanship under normal use and service for a period of three (3) years from the date of shipment, except the batteries, which are warranted for one (1) year from the date of shipment. Integra s sole and exclusive liability under the warranty shall be, at Integra s option, either to repair or replace any component which fails during the warranty period due to any defect in workmanship or material, F.O.B. factory if: 1. Customer promptly reports such defect to Integra in writing, 2. If requested by Integra, customer returns equipment to Integra with shipping charges paid by Integra 3. Upon inspection, Integra finds the equipment to be defective. This warranty is contingent upon normal and proper use of the. It does not cover equipment that has been modified with non-integra parts without the written approval of Integra, subjected to unusual physical or electrical stress, or damaged during shipment. This warranty is non-transferable unless authorized in writing by Integra. Integra reserves the right to make design changes on its products without liability to incorporate said change in Integra products previously designed or sold. Upon receipt of the product, it should be carefully inspected. If any defect is discovered, notification must be given immediately to the manufacturer or authorized distributor. 20

22 Integra Manufactured by: Integra Burlington MA, Inc 22 Terry Avenue Burlington, MA Authorized EU Representative: Integra LifeSciences Services France Immeuble Séquloa 2, 97 allée Alexandre Borodine Parc Technologique de la Porte des Alpes Saint Priest - France +33 (0) For more information or to place an order, please contact: Integra n 311 Enterprise Drive, Plainsboro, NJ USA n outside USA n fax integralife.com Integra and the Integra logo are trademarks of Integra LifeSciences Corporation in the United States and/or other countries Integra LifeSciences Corporation. All rights reserved. Printed in the USA. P/N Rev. A

Charging Station - Instructions For Use

Charging Station - Instructions For Use Charging Station - Instructions For Use READ THE HYBRESIS CONTROLLER AND PATCH INSTRUCTIONS FOR USE FOR ADDITIONAL IMPORTANT INFORMATION. REF: 199586 GLOSSARY OF SYMBOLS This device may contain one or

More information

Power Blade Charger Users Guide

Power Blade Charger Users Guide Power Blade Charger Users Guide Desktop Configuration Wall Mount Configuration Desktop Configuration (Displayed with Jaco Power Blade Batteries and 300 Series Laptop and LCD carts. Sold separately) 25-0180

More information

UNIVERSAL BATTERY CHARGER II

UNIVERSAL BATTERY CHARGER II UNIVERSAL BATTERY CHARGER II USER S MANUAL TABLE OF CONTENTS INTRODUCTION General Information 2 Intended use 2 Compatibility 2 Abbreviations 2 Safety precautions 3 Scope of delivery 3 Storage and transport

More information

ELORA BATTERY INTERFACE. Owner s Manual

ELORA BATTERY INTERFACE. Owner s Manual ELORA BATTERY INTERFACE Owner s Manual CONTENTS 3 4 7 8 12 19 IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE OPERATION INTRODUCTION KEY FEATURES AND BENEFITS ORDERING INFORMATION MOUNTING FUEL GAUGE

More information

LED-HL2-CMP LED Headlight System Operation Manual

LED-HL2-CMP LED Headlight System Operation Manual LED-HL2-CMP LED Headlight System Operation Manual Manufactured for: Cardio Medical Products, Inc. 385 Franklin Avenue, Suite L Rockaway, NJ 07866 USA Customer Service: 800-227-3633 info@cardiomedicalproducts.com

More information

6 Bay Battery Charger Operation Manual

6 Bay Battery Charger Operation Manual 6 Bay Battery Charger Operation Manual Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216 USA Customer Service: 904 737 7611 Toll Free 877 677 2832 EC REP RMS UK, Ltd. 28 Trinity Road

More information

Blades with the MatrixPRO Driver may result in damage to the MatrixPRO Driver and/or screwdriver blades, and should

Blades with the MatrixPRO Driver may result in damage to the MatrixPRO Driver and/or screwdriver blades, and should Description: The MatrixPRO Driver (05.000.020) is designed to insert DePuy Synthes MatrixNEURO TM Self Drilling Screws (3 4mm lengths) and Low Profile Neuro Self Drilling Screws (3 4mm lengths) and features

More information

Universal Battery Charger II.

Universal Battery Charger II. Universal Battery Charger II. Instructions for Use This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation Table of Contents Introduction General

More information

Operator s Manual. Pre-Clinical Blood Sampling Tool

Operator s Manual. Pre-Clinical Blood Sampling Tool Operator s Manual Pre-Clinical Blood Sampling Tool + Read the entire Operator s Manual before using GentleSharp Model 101. Disregarding the cautions and instructions presented in this manual constitutes

More information

Hand-held Fundus Camera (Model :HFC) Operating Manual

Hand-held Fundus Camera (Model :HFC) Operating Manual Hand-held Fundus Camera (Model :HFC) Operating Manual V1.0 July. 2015 Preface Thank you for purchasing our HFC (Handheld Fundus Camera). Please read this manual carefully before using this instrument in

More information

Simplicity Light Post Mount

Simplicity Light Post Mount Simplicity Light Post Mount Table of Contents Section I Introduction Specifications... 2 Classifications...2-3 Packaging... 3 Section II Installation Post Mount with Service Console...4-5 Section III Operation

More information

HEINE NT4 MED V

HEINE NT4 MED V HEINE NT4 MED 113594 2018-01-23 V-200.00.601 HEINE NT4 Please read and follow these instructions for use and keep them for future reference. Intended Use The HEINE charger NT4 is to be used exclusively

More information

DenLite Illuminated Dental Mirror

DenLite Illuminated Dental Mirror DenLite Illuminated Dental Mirror Directions for Use DenLite Illuminated Dental Mirror Miltex, Inc. assumes no responsibility for any injury to anyone, for any illegal or improper use of the product that

More information

Installation Operation Maintenance Troubleshooting Version Dec/ EL / Biscayne E.L.

Installation Operation Maintenance Troubleshooting Version Dec/ EL / Biscayne E.L. Installation Operation Maintenance Troubleshooting Version Dec/17 6000EL / Biscayne E.L. Table of Contents DEAR CUSTOMER... 3 PRODUCT DESCRIPTION... 3 CLASSIFICATIONS... 4 GENERAL DATA... 8 TECHNICAL SPECIFICATIONS...

More information

SurePower Battery Pack Guide

SurePower Battery Pack Guide ? SurePower Battery Pack Guide 9650-0536-01 Rev. B The issue date for the SurePower Battery Pack Guide (9650-0536-01 Rev. B) is September, 2010. If more than three years have elapsed since the issue date,

More information

ZOLL Base PowerCharger 1x1. Operator s Manual

ZOLL Base PowerCharger 1x1. Operator s Manual ZOLL Base PowerCharger 1x1 Operator s Manual The revision level for this document is shown on the front cover. ZOLL, PowerCharger 1x1, QuickCharge, and AutoTest are trademarks of ZOLL Medical Corporation.

More information

SurePower TM II Battery Pack Guide

SurePower TM II Battery Pack Guide TM SurePower TM II Battery Pack Guide? 1:00+ 2:00+ 3:00+ TM 9650-000840-01 Rev. B The issue date for the SurePower II Battery Pack Guide (REF 9650-000840-01 Rev. B) is December, 2012. If more than three

More information

1 Intended Use. 2 Precautions for handling and operation. English

1 Intended Use. 2 Precautions for handling and operation. English Thank you for purchasing the NSK icare. Please read this Operation Manual carefully before use to become familiar with operation instructions and care & maintenance. Keep this Operation Manual for future

More information

Gutta Percha Heating System

Gutta Percha Heating System Gutta Percha Heating System Instructions for Use PLEASE READ ALL INSTRUCTIONS PROVIDED FOR THIS DEVICE BEFORE USING IT. Caution: This product should only be used by dental professionals. The Obtura Spartan

More information

MIDAS REX ELECTRIC BONE MILL BM110 & BM120

MIDAS REX ELECTRIC BONE MILL BM110 & BM120 MIDAS REX ELECTRIC BONE MILL BM110 & BM120 User s Guide Rx Only The information contained in this document was accurate at time of publication. Medtronic reserves the right to make changes in the product

More information

R06 JH 03/19/13 EN-INTL SimplyGo USER MANUAL

R06 JH 03/19/13 EN-INTL SimplyGo USER MANUAL 1083703 1069062 R06 JH 03/19/13 EN-INTL SimplyGo USER MANUAL Table of Contents Introduction...1 Intended Use...1 Contraindications...1 Device and Accessories Description...1 SimplyGo System...2 Warnings

More information

SurePower Charger Station Operator s Guide

SurePower Charger Station Operator s Guide SurePower Charger Station Operator s Guide 9650-0535-01 Rev. C The issue date for the SurePower Charger Station Operator s Guide (REF 9650-0535-01 Rev. C) is April, 2015. If more than three years have

More information

PAP battery kit. Lithium ion battery with integrated uninterruptible power supply (UPS)

PAP battery kit. Lithium ion battery with integrated uninterruptible power supply (UPS) PAP battery kit Lithium ion battery with integrated uninterruptible power supply (UPS) Manufactured for: Respironics Inc. 1001 Murry Ridge Lane Murrysville, PA 15668 USA 1126218 Respironics Deutschland

More information

XENON 300 LIGHT SOURCE

XENON 300 LIGHT SOURCE XENON 300 LIGHT SOURCE Thank you for purchasing the Welch Allyn Xenon 300 Light Source. By following the use and care guidelines given in this booklet, you will be rewarded with years of dependable, trouble-free

More information

Electric Handpiece System OPERATION MANUAL

Electric Handpiece System OPERATION MANUAL 0344 Electric Handpiece System OPERATION MANUAL OM-EZ505E The EU directive 93/42/EEC was applied in the design and production of this medical device. Please Read this operation manual carefully before

More information

Welch Allyn Insight Wireless LED Binocular Indirect Ophthalmoscope. Directions for use

Welch Allyn Insight Wireless LED Binocular Indirect Ophthalmoscope. Directions for use Welch Allyn 13500 Insight Wireless LED Binocular Indirect Ophthalmoscope Directions for use 2017 Welch Allyn. All rights are reserved. To support the intended use of the product described in this publication,

More information

Xenon Fiberoptic Lightsource

Xenon Fiberoptic Lightsource Xenon Fiberoptic Lightsource Operating Instructions for ASB-XE-175W Lightsource 2659A Pan American Frw N.E Albuquerque, New Mexico 87107 USA (English) Page 1 of 12 TABLE OF CONTENTS PAGE 1. INTRODUCTION

More information

MatrixPRO Driver Instructions for Use

MatrixPRO Driver Instructions for Use DESCRIPTION: The MatrixPRO Driver (05.000.020) is designed to insert DePuy Synthes MatrixNEURO TM Self-Drilling Screws (3-4mm lengths) and Low Profile Neuro Self-Drilling Screws (3-4mm lengths) and features

More information

ACTIVE COLD COMPRESSION DEVICE & COLD PACK INSTRUCTIONS FOR USE

ACTIVE COLD COMPRESSION DEVICE & COLD PACK INSTRUCTIONS FOR USE INSTRUCTIONS FOR USE ACTIVE COLD COMPRESSION DEVICE & COLD PACK GO DEEP TABLE OF CONTENTS PACKAGE COMPONENTS & ACCESSORIES 1 TECHNICAL DESCRIPTION 2 INDICATIONS FOR USE 3 CONTRAINDICATIONS 4 SAFETY INFORMATION

More information

v900l TM Visualization System

v900l TM Visualization System v900l TM Visualization System Directions for Use v900l-dfu Doc #9001_1 TM Scientific Syris Scientific Syris Scientific, LLC. 22 Shaker Rd., P.O. Box 127, Gray, Maine, USA 04039 Phone: 207.657.7050 Fax:

More information

Visum XBlade LED Exam Light. Operations Manual

Visum XBlade LED Exam Light. Operations Manual Visum XBlade LED Exam Light Operations Manual Contents S 1. Indications for Use...5 1.1 Device Description...5 1.2 Intended User Profile...5 2. Warnings and Cautions...6 2.1 Warnings...6 2.2 Cautions...7

More information

User Manual. Patient Programmer Recharger for Deep Brain Stimulation. Beijing PINS Medical Co., Ltd. MODEL R801. Beijing PINS Medical Co., Ltd.

User Manual. Patient Programmer Recharger for Deep Brain Stimulation. Beijing PINS Medical Co., Ltd. MODEL R801. Beijing PINS Medical Co., Ltd. Beijing PINS Medical Co., Ltd. 1st Floor and 5th Floor Building 1,No.1,Xingchang Road Changping Science Park Beijing 102200 P. R. China E-mail: service_en@pinsmedical.com www.pinsmedical.com Patient Programmer

More information

Resuscitation System Model 100

Resuscitation System Model 100 Resuscitation System Model 100 AutoPulse Power System User Guide P/N. 12457-001 Rev. 4 Notice About this Guide The information in this User Guide applies to the ZOLL AutoPulse Power System designed for

More information

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH OPERATING MANUAL POWER DRIVE SYSTEM Cat. No. 400005 525-1300-00 RevH System components Symbol Definitions Qty Description Catalog Number 1 Power Drive System 300106 1 Controller 300108 1 Cutter Drive

More information

PORTABLE SUCTION ASPIRATOR

PORTABLE SUCTION ASPIRATOR PORTABLE SUCTION ASPIRATOR PART NUMBER 758000 OPERATOR / MAINTENANCE M A N U A L P a g e 2 The care-e-vac 3 is a portable medical aspirator to suction fluids or foreign bodies from a patient. The medical

More information

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority VX-2 Model 2310 Series Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com techsupport@sscor.com

More information

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty. 729/729 FC Automatic Pressure Calibrator Safety Information 3-Year Limited Warranty. See the Users Manual for the full warranty. Go to Fluke's website at www.fluke.com to read the User Manual and find

More information

OPERATION MANUAL. Motor Handpiece System for Root Canal Enlargement

OPERATION MANUAL. Motor Handpiece System for Root Canal Enlargement Motor Handpiece System for Root Canal Enlargement OPERATION MANUAL OM-E0202E 001 Please Read this operation manual carefully before use and keep for future reference. Thank you for purchasing the EndoDrive

More information

Setting New Standards through Innovation FUSION INSTRUCTIONS FOR USE. Ortho LED Curing Light System (Rev 4) Powered by Patented Focus Beam Technology

Setting New Standards through Innovation FUSION INSTRUCTIONS FOR USE. Ortho LED Curing Light System (Rev 4) Powered by Patented Focus Beam Technology Setting New Standards through Innovation FUSION INSTRUCTIONS FOR USE Ortho LED Curing Light System (Rev 4) Powered by Patented Focus Beam Technology Product Information Description and Indications for

More information

Owner s Manual Ultra DBI TM Model: 9400

Owner s Manual Ultra DBI TM Model: 9400 Owner s Manual Ultra DBI TM Model: 9400 Owner Model Serial # Date Medical Positioning, Inc. 1146 Booth Street, Kansas City, Kansas 66103 T: 816-474-1555 1-800-593-3246 www.medicalpositioning.com Table

More information

Keeler Spectra Plus. Instructions. Next

Keeler Spectra Plus. Instructions. Next Keeler Spectra Plus Instructions Next Introduction Thank you for purchasing the Keeler Spectra Plus Indirect Ophthalmoscope. We have taken the greatest care in the design, development and manufacture of

More information

EDITION : A. Description: SCALE : 100% (L4 FFL-201 ANZ) manual artwork PART NO COLOR ITEM ID. MATERIAL 50gsm recycle paper REV.

EDITION : A. Description: SCALE : 100% (L4 FFL-201 ANZ) manual artwork PART NO COLOR ITEM ID. MATERIAL 50gsm recycle paper REV. Description: EDITION : A 018331003(L4 FFL-201 ANZ) manual artwork SCALE : 100% PART NO ITEM ID REV. 961001550 MODEL NO 018331003 COLOR Black CM00166845 DIELINE 01 SIZE unfold:280mmx203mm; fold:70mmx26mm(+/-2mm)

More information

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority Quickdraw Model 2400 Series Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com

More information

Clinical Electric OPERATION MANUAL

Clinical Electric OPERATION MANUAL Clinical Electric OPERATION MANUAL Electric Micromotor Standard Electric Micromotor Miniature Please Read this operation manual carefully before use and keep for future reference. OM-ER206E Autoclavable

More information

USER S GUIDE 2880 SERIES. 3 Safety Instructions. Product View. Assembly 4-5. Operation. Maintenance and Care. Troubleshooting.

USER S GUIDE 2880 SERIES. 3 Safety Instructions. Product View. Assembly 4-5. Operation. Maintenance and Care. Troubleshooting. USER S GUIDE 2880 SERIES 3 Safety Instructions 4 Product View 4-5 Assembly 5 Operation 6 Maintenance and Care 7 Troubleshooting 7 Replacement Parts 8 Warranty Thanks for buying a BISSELL Perfect Sweep

More information

R0 JH 11/3/11. SimplyGo

R0 JH 11/3/11. SimplyGo 1083700 1079142 R0 JH 11/3/11 SimplyGo Table of Contents Introduction...1 Intended Use...1 Contraindications...1 Device and Accessories Description...1 SimplyGo System...2 Warnings and Cautions...3 Symbol

More information

USER'S GUIDE 9151 SERIES V

USER'S GUIDE 9151 SERIES V USER'S GUIDE 9151 SERIES 220-240 V 2 Thank You 3 Safety Instructions 4 Product View 4-5 Assembly 5 Operations 6 Maintenance and Care 7 Troubleshooting 7 Replacement Parts 8 Warranty 8 Consumer Care Thanks

More information

OAKWORKS 300 Series Procedure Chair

OAKWORKS 300 Series Procedure Chair USER MANUAL OAKWORKS 300 Series Procedure Chair www.oakworksmed.com 717.235.6807 made in the USA with US & imported parts Copyright 2013 OAKWORKS, Inc. Notice This manual was originally drafted and approved

More information

OAKWORKS 300 Series Procedure Chair

OAKWORKS 300 Series Procedure Chair User MANUAL OAKWORKS 300 Series Procedure Chair www.oakworksmed.com 717.235.6807 made in the USA with US & imported parts Copyright 2013 OAKWORKS, Inc. Notice This manual was originally drafted and approved

More information

Switching DC Power Supply

Switching DC Power Supply 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary

More information

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority DCell Suction Model DM10-001 Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com

More information

Ti200, Ti300, Ti400, Ti450, Ti480 Thermal Imagers

Ti200, Ti300, Ti400, Ti450, Ti480 Thermal Imagers Ti200, Ti300, Ti400, Ti450, Ti480 Thermal Imagers Safety Information 2-Year Limited Warranty. See the Users Manual for the full warranty. Go to www.fluke.com to register your product, download manuals,

More information

Language specific user manuals are available on

Language specific user manuals are available on User Manual WEB Charger for LiFePO 4 Batteries EN User Manual Language specific user manuals are available on www.mascot.no/downloads/usermanuals Bruksanvisning Käyttöohjeet Bedienungsanleitung Mode d

More information

IsoLED FLEX I CUSTOMER MANUAL

IsoLED FLEX I CUSTOMER MANUAL IsoLED FLEX I CUSTOMER MANUAL 1 IsoLED FLEX I CUSTOMER MANUAL Document No. OM-1221-C Version 1.0 AUGUST 14, 2015 ISOLUX LLC 1045 Collier Center Way Suite 6 Naples FL, 34110 2 TABLE OF CONTENT TABLE OF

More information

3-Year Limited Warranty. See the Users Manual for the full warranty.

3-Year Limited Warranty. See the Users Manual for the full warranty. MDA-550/MDA-510 Motor Drive Analyzer Safety Information 3-Year Limited Warranty. See the Users Manual for the full warranty. Go to www.fluke.com to register your Product, read the Users Manual, and find

More information

Fixed Ceiling Lift FL

Fixed Ceiling Lift FL Savaria Fixed Ceiling Lift FL OWNER S MANUAL To Be Retained by Owner After Installation by Authorized Savaria Dealer Part No. 001108-EN Rev. 00 -m -201 2 IMPORTANT Be sure to read this entire manual before

More information

Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers

Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers Safety Information 2-Year Limited Warranty. See the Users Manual for the full warranty. To register your product, visit www.fluke.com.

More information

OWNER S MANUAL Please read and understand all precautions prior to use.

OWNER S MANUAL Please read and understand all precautions prior to use. INPUT: 120V AC 60Hz 250mA. OUTPUT: 14.4V DC 500mA. OWNER S MANUAL Please read and understand all precautions prior to use. Thank you for choosing a premium New Bright product. USA & Canada 30-Day Limited

More information

MULTI-FUNCTION JUMP STARTER

MULTI-FUNCTION JUMP STARTER MULTI-FUNCTION JUMP STARTER FEATURES 1. Flashlight 2. Jump Start Port 3. LED Power indicator 4. USB Output 5. Power button 6. Charging port 7. Car battery clamp 8. Home charger&car charger 9. Portable

More information

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A RemRest Tiers 1-3 900 Series Service Manual CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N 22054 Rev A Table of Contents IEC Symbols 3 SIZE 4.7" H X 8.6"

More information

The device Vulcan has the function of rotating electric engines.

The device Vulcan has the function of rotating electric engines. Vulcan User Manual Vulcan is a device manufactured with the latest technology and all devices is tested individually. The device has the INMETRO seal and registration with the Brazilian Health Surveillance

More information

LIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063

LIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063 LIGHTBOLT MAX EXTENDABLE WORK LIGHT Model No. 4063 INSTRUCTION MANUAL MobilePower, LLC. Miami, FL www.mobilepower-us.com Customer Support: (800) 708-8550 customerservice@mobilepower-us.com BEFORE YOU USE

More information

Operating Instructions

Operating Instructions Operating Instructions Contents Introduction 1 Operating Instructions 2-7 Storing/Handling/Cleaning 7 Safety Precautions 7-8 Specifications 9 FCC Compliance Statement 9-10 Limited Warranty 10-11 Contact

More information

EMB-901 Built In Fiber Optic Brushless Electric Micromotor Set Operation Manual

EMB-901 Built In Fiber Optic Brushless Electric Micromotor Set Operation Manual High / Low Speed Handpiece for Dental EMB-901 Built In Fiber Optic Brushless Electric Micromotor Set Operation Manual Content 1.Component Instructions...03 2.Symbols...04 3.Description of Products...05

More information

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide Podiatry Procedures Chair For Models: 646 647 Barrier-Free User s Guide Product Information (The information below is required when calling for service.) Dealer : Date of Purchase: Model / Serial Number:

More information

Please read and understand all precautions prior to use.

Please read and understand all precautions prior to use. INPUT: 120V AC 60Hz 8W. OUTPUT: 13V DC 440mA. OWNER S MANUAL Please read and understand all precautions prior to use. Thank you for choosing a premium New Bright product. L897121239/JN113-16 CONTENTS Component

More information

PM-X IR SURGICAL POWER & ACCESSORIES

PM-X IR SURGICAL POWER & ACCESSORIES PM-X12-700-IR-12.13 SURGICAL POWER & ACCESSORIES Table of Contents Introduction Page 4 Intended Use Page 4 Warnings Page 4 Cautions Page 6 Explanation of Symbols Page 7 Features Page 8 Battery Pack - Installation

More information

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY MB3730 12V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY 1 IMPORTANT SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS - This manual contains important safety and operating instructions for this PowerStation.

More information

Owner's Manual. For latest instructions please go to

Owner's Manual. For latest instructions please go to mycharge name and logo are registered trademarks of RFA Brands. 2012-2013 RFA Brands. All Rights Reserved. Patent Pending. Made in China. IB-MYC0600 Owner's Manual For latest instructions please go to

More information

PM-X IR SURGICAL POWER & ACCESSORIES

PM-X IR SURGICAL POWER & ACCESSORIES PM-X14-700-IR-12.13 SURGICAL POWER & ACCESSORIES Table of Contents Introduction Page 4 Intended Use Page 4 Warnings Page 4 Cautions Page 6 Explanation of Symbols Page 7 Features Page 8 Battery Pack -

More information

Invacare. Battery Charger User Manual. Model: POC1 115, POC1 115 AZ, POC1 115 C, POC1 115 EU

Invacare. Battery Charger User Manual. Model: POC1 115, POC1 115 AZ, POC1 115 C, POC1 115 EU Invacare Model: POC1 115, POC1 115 AZ, POC1 115 C, POC1 115 EU en Battery Charger User Manual This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save

More information

1 User and Intended Use. 2 Precautions for handling and operation. English. Thank you for purchasing the VarioSurg 3.

1 User and Intended Use. 2 Precautions for handling and operation. English. Thank you for purchasing the VarioSurg 3. Thank you for purchasing the VarioSurg 3. Please read this Operation Manual carefully before use to become familiar with operation instructions and care & maintenance. Keep this Operation Manual for future

More information

PlayPRO. Vascular Therapy System (Compressible Limb Sleeve Device)

PlayPRO. Vascular Therapy System (Compressible Limb Sleeve Device) Triple PlayPRO Vascular Therapy System (Compressible Limb Sleeve Device) Manufactured for: Wildcat Medical, Inc. dba: Compression Solutions 817 E. 4th Street Tulsa, OK 74120 USA Customer Service Toll Free:

More information

Powerware Vdc Extended Battery Cabinet User s Guide.

Powerware Vdc Extended Battery Cabinet User s Guide. Powerware 9125 48 Vdc Extended Battery Cabinet User s Guide www.powerware.com FCC Part 15 Class A EMC Statements NOTE This equipment has been tested and found to comply with the limits for a Class A digital

More information

User guide User guide English

User guide User guide English User guide English Contents Welcome... 1 Indications for use... 1 Contraindications... 1 At a glance... 4 About your device... 5 Control panel... 6 Display screen... 7 Getting started... 8 Using the carrying

More information

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # / ITEM #0506882 / 0506883 40 V LITHIUM-ION BATTERY MODEL #KB 240-06 / KB 440-06 Français p. 7 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date AB13786C 1 PRODUCT SPECIFICATIONS Battery

More information

Owner s Manual EchoBed X VasScan Table X

Owner s Manual EchoBed X VasScan Table X Owner s Manual EchoBed X VasScan Table X Owner Model Serial # Date Echo/Vascular User Manual (15381-C) Page 1 of 46 DCR-00172 Table of Contents Symbols and Definitions... 3 Safety Warnings & Cautions...

More information

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on User Manual Charger for LTO Batteries EN User Manual Language specific user manuals are available on www.mascot.no/downloads/usermanuals Bruksanvisning Käyttöohjeet Bedienungsanleitung Mode d emploi Manual

More information

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual Sentinel Enteral Feeding Pump Model: S-1000-SI Operating Manual CONTENTS 1. Introduction.. 2 2. Control Panel 5 3. Operating Instructions.. 6 4. Indicators and Alarms.. 9 5. Maintenance.. 10 6. Troubleshooting

More information

Manual of use and maintenance

Manual of use and maintenance Manual of use and maintenance Summary 00.0 Introduction......4 00.1 Foreword......4 00.2 Description of the apparatus......4 00.3 Intended use......4 00.4 Safety requirements......5 01.0 Identification

More information

Owner's Manual. For latest instructions please go to

Owner's Manual. For latest instructions please go to mycharge name and logo are registered trademarks of RFA Brands. 2012-2013 RFA Brands. All Rights Reserved. Patent Pending. Made in China. IB-RFAM0237 Owner's Manual For latest instructions please go to

More information

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems OPERATION AND MAINTENANCE INSTRUCTION MANUAL AEU-707A & AEU-707AV2 Implant / Surgery Systems TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up the

More information

Handheld LED Light Source (HLS) Operator s Manual

Handheld LED Light Source (HLS) Operator s Manual This device is covered under US Patents issued and pending. Handheld LED Light Source (HLS) Operator s Manual Sales and Service by: Myriad Fiber Imaging 56 Southbridge Road Dudley, MA 01571 USA USA Tel:

More information

1. D-Lux Introduction ENGLISH Parts & Components Product Overview. 4. Precautions. 5. Hand-piece Components Installation

1. D-Lux Introduction ENGLISH Parts & Components Product Overview. 4. Precautions. 5. Hand-piece Components Installation 1. D-Lux Introduction ENGLISH D-Lux is a new advanced cordless LED curing light. Made from the highest quality aluminum, D-Lux dissipates heat quickly to prevent overheating problem so that it can produce

More information

400 Watt Backup Power System Owner s Manual

400 Watt Backup Power System Owner s Manual 400 Watt Backup Power System Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

MS Medical Scale USER MANUAL. Please keep the instruction manual at hand all the time for future reference

MS Medical Scale USER MANUAL. Please keep the instruction manual at hand all the time for future reference MS 3800 Medical Scale USER MANUAL Please keep the instruction manual at hand all the time for future reference. - 0 - TABLE OF CONTENTS PREFACE... 2 GENERAL INFORMATION... 2 SAFETY INSTRUCTION... 2 ENVIROMENTAL...

More information

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS R A Valley Forge Company MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS 1. INTRODUCING THE CHARGER The 2602A-12 is a 3-stage electronic battery charger. Rainproof,

More information

English ATMOS LS 21 LED. Light source. Operating Instructions. GA1GB Index: 13

English ATMOS LS 21 LED. Light source. Operating Instructions. GA1GB Index: 13 English ATMOS LS 21 LED Light source Operating Instructions GA1GB.150302.0 2017-11 Index: 13 ATMOS MedizinTechnik GmbH & Co. KG Ludwig-Kegel-Straße 16 79853 Lenzkirch Germany Phone +49 (0) 76 53 / 689-0

More information

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems OPERATION AND MAINTENANCE INSTRUCTION MANUAL AEU-17B & AEU-17BV2 Implant / Surgery Systems TABLE OF CONTENTS: Specifications........................i Introduction.........................1 Package Contents....................1

More information

MICRO-START SAFETY GUIDE

MICRO-START SAFETY GUIDE ANTIGRAVITY BATTERIES MICRO-START ALL MODELS 2018 CONTENTS: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 IMPORTANT INTRODUCTION PERSONAL PRECAUTION MINORS CHOKING HAZARD HANDLING MODIFICATIONS ACCESSORIES

More information

Owner's Manual. For latest instructions please go to

Owner's Manual. For latest instructions please go to mycharge name and logo are registered trademarks of RFA Brands. 2012-2013 RFA Brands. All Rights Reserved. Patent Pending. Made in China. IB-RFAM0232 Owner's Manual For latest instructions please go to

More information

Product Data Sheet : LIGHTHAWK 6 CELL

Product Data Sheet : LIGHTHAWK 6 CELL Specifications Power Source: Lithium-Ion, 6600mAH, 7.8V Lamp: XPR12, PN 20356 Lamp Life: 100 hrs Light Output: 264 lumens Burn Time: up to 4 hrs. 4.5 Hour Charging Time Weight: 2.1 lbs Unit Dimensions:

More information

Contents. 1. Warnings and Cautions Warnings Cautions... 3

Contents. 1. Warnings and Cautions Warnings Cautions... 3 Contents 1. Warnings and Cautions... 2 1.1 Warnings... 2 1.2 Cautions... 3 2. Vein Finder Overview... 4 2.1 Intended Use... 4 2.2 Product Descriptions... 4 2.3 VS400 Symbol Definitions... 6 2.4 Displays...

More information

Operating Manual. Follow all safety precautions!

Operating Manual. Follow all safety precautions! Operating Manual This manual contains important information necessary for the safe and efficient operation of the PhotoFluor LM-75 light source. Please read the manual in its entirety and heed all safety

More information

Operating Instructions for PAC800 Battery Charger

Operating Instructions for PAC800 Battery Charger Operating Instructions for PAC800 Battery Charger General Safety The charger may only be used for the specified battery types. This battery charger is supplied with pre-set charging curves that are adapted

More information

10 AMP ON BOARD BATTERY CHARGER

10 AMP ON BOARD BATTERY CHARGER R A Valley Forge Company MODEL 2611A-1-B 10 AMP ON BOARD BATTERY CHARGER One Output OWNER S MANUAL IMPORTANT! READ THESE INSTRUCTIONS BEFORE INSTALLING AND USING THIS PRODUCT. Keep these instructions for

More information

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System USER MANUAL Blazer Vista 1000/1400/2000 Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for model Blazer Vista 1000/1400/2000

More information

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE W.CHRISTIE (INDUSTRIAL) LTD CHRISTIE HOUSE, MEADOWBANK ROAD, ROTHERHAM, SOUTH YORKSHIRE, S61 2NF, UK T: +44(0)1709 550088 F: +44(0)1709 550030 E:

More information

LED Pinspot 2. Snapshot. User Manual

LED Pinspot 2. Snapshot. User Manual LED Pinspot 2 Snapshot Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave Auto-ranging Power Supply Replaceable Fuse User-Serviceable User Manual 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.

More information

15 N ONE Multi-Purpose Vehicle Jumpstart System

15 N ONE Multi-Purpose Vehicle Jumpstart System 15 N ONE Multi-Purpose Vehicle Jumpstart System Double Injection Casing with Rubberized Protective Bumper Guards 400 Watt Continuous 800 Watt Peak Inverter With two 110 V AC Outlets Two Detachable LED

More information