Polymer Insulator. ITEM 15kV 25kV 35kV 69kV. Section length(l) 330±15mm 445mm 539mm 888mm. Min. arcing distance 215mm 300mm 340mm 701

Size: px
Start display at page:

Download "Polymer Insulator. ITEM 15kV 25kV 35kV 69kV. Section length(l) 330±15mm 445mm 539mm 888mm. Min. arcing distance 215mm 300mm 340mm 701"

Transcription

1 Polymer Insulator Characteristics of Polymer Insulator The main element of polymer insulator displays very excellent properties in terms of heatproof performance, chemical stability, electrical insulation, wear resistance and glossy performance compared to general organic rubbers thanks to its both sides nature-organic and inorganic properties expressed simultaneously by silicone. Merits of Polymer Insulator 1. Light weight : Lighter than porcelain insulator, providing easy work and shortened period of construction(reducing power interference by shortened electricity failure time) 2. Elastic body : Easier handing and transportation by reduced damage from careless 3. Weather resistance : Reducing maintenance cost without need for washing or cleaning 4. Water repellency : Excellent insulation performance with water-resistion properties Product Picture Specification ITEM 15kV 25kV 35kV 69kV Section length(l) 330±15mm 445mm 539mm 888mm Dimension Leakage distance 439mm 642mm 850mm 2037mm Min. arcing distance 215mm 300mm 340mm 701 Electrical Rating Mechanical Rating Low frequency dry flash over voltage test Low frequency wet flash over voltage test Critical impulse flashover voltage test Radio influence Voltage test Positive Negative Max. Voltage test 1(Max) 1(Max) 1(Max) 3 Phase to earth Failing load test 700kgf 700kgf 700kgf 1000kgf Number of sheds

2 CUT OUT SWITCH Introduction The Cut out switch is used with expulsion fuse links for sectionalizing and transformer protection. Features of cut out switchs include, Fuse holders are mutually Interchangeable with the other company s cutouts. Single vent and drop-out type. Repeated usability after operation (replace the fuse link only) Cut out provide reliablee protection from low level overload that just melt the fuse link. Superior breaking capability from intermediate through maximum interrupting current. Product Picture Drop-out action Outdoor distribution Single-Insulator (Polymer) Light-Weight Hot Stick operation Specification Bending Nominal Power freq. voltage Lighting Impulse No. TYPE Withstand Creepage Withstand Load(kN) Distance(mm) Dry Wet voltage(kv) 1 YJC27K YJC36K

3 LIGHTNING ARRESTER Introduction & Installation Polymer-housed arresters are used for limiting the overvoltage due to a lightning and switching surge to the required protective level. The superior protective characteristics of arrester provide level. The superior protective characteristics of arrester provide excellent overvoltage protection for distribution system equipments. Features of arresters include, Light weight and easy installation. Excellent discharge capacity compared with porcelain-housed arrester Verified the performance in contaminated environments. Insulated mounting base and ground lead isolator, wildlife protector available(optionally). Product Picture 10kV Electrical Character TYPE Rated Voltage(kN ) MCOV (kv) Steep Current Impulse Switching Current Impulse Lighting Current Impulse High Current Impulse KW10A KW10A KW10A KW10A KW10A KW10A KW10A KW10A

4 INTERRUPTER SWITCH Introduction Interrupter switch(lbs) is a three phase transmission part operated swith utilized to sectionalize or isolate circuits on electrical distribution systems up through 25.8KV, the distribution switch is rated for 600 amperes continuous current and amperes momentary. Specification Items Data Origin Rated voltage(kv) 24/25.8 Rated current(a) 600/630 Momentary(KA) 40 1 sec(ka) 25 Rated frequency(hz) 50/60 Han Sung/ Withstand voltage(1 Min, Dry)(KV) 70 Korea Impulse withstand voltage(kv) 150 Support insulator (polymer) TR-208 Weight(Kg) 90 Tolerance ±5%

5 Vertical Axis Wind Turbine Introduction This product can be used by in any areas where has good wind resource, such as building roofs in cities, environment favorable buildings, and dependent small power stations in suburbs. It can provide stable and reliable electricity for lighting, household electrical appliances, beacon light, microwave communication, equipment, meters. It is ideal power supply equipment for families and companies. Specification P - 10 Mill diameter:30cm Blade length:30cm Start up wind speed: Working wind speed: 4.20m/ /s Rating wind speed: 10m/s Safe wind speed: 40m/s Rating out put: DC 12V Brake style: Mechanism Net weight: 20kg (No pillar) P Mill diameter:138cm Blade length:130cm Start up wind speed: 2m/s Working wind speed: 4-25m/ /s Rating wind speed: 10m/s Safe wind speed: 40m/s Rating out put: DC28/36V Brake style: Mechanism Pillar high: 5.5m Net weight: 90 Kg (No Pillar)

6 P Mill diameter:180cm Blade length:200cm Start up wind speed: 2m/s Working wind speed: 4-25m/ /s Rating wind speed: 12m/s Safe wind speed: 50m/s Rating out put: DC48V Brake style: Mechanism Pillar high: 5.5m Net weight: 180 Kg (No Pillar) P 3000 Milll diameter:300cm Blade length:360cm Start up wind speed: 2m/s Working wind speed: 4-25m/s Rating wind speed:12m/s Safe wind speed: 50m/ /s Rating out put: AC230/ /115V Brake style: Mechanism Pillar high: 5.5m/11m Net weight: 500 Kg (No Pillar)

7 SOLAR HOME SYSTEM General Information. I. Use MCU and professional software as the control center to fulfill intelligent system control. II. The accurate control point depends on the battery discharge rate, final discharging voltage is the control point of corrected discharging curve. eliminate the discrepancy by the single voltage control, meet the battery characteristics, which is different charge rate has different final voltage. III. With intelligent protection against over charging, over discharging, electronicc short-circuit, over load, polarity reverse and etc. no damage for any components, and no burning for the fuse. IV. With series PWM charging circuit, the voltage loss of charging loop is only half of the LED charging circuit, the charging efficiency is higher 3% %-6% than the ON/OFF one, and saved the energy. The boost, direct, and float charging enhanced the lifetime of the system. Also it has specific temperature compensation. V. Direct LED indicator for the statues of the system. With flash memory saving the control make the setting digital, eliminate the discrepancy. VI. One key setting, easy and convenient. Specifications Type Rated charge current Rated DC load current Rated AC load Capacity Work voltage Solar home system 50W MAX DC 10A MAX DC 10A MAX 150W DC 12V / AC 220V

8 1.25 rated load current 60sec Over load, short circuit protection DC 1.5 rated loads current 5sec over load protection action. 3 Rated load current short circuit protection action. AC Fuse Quiescent current 6 ma Charge circuit voltage drop DC 0.26V Load circuit voltage drop DC 0.15V Over voltage protection Work temperature Boost charge voltage Direct charge voltage 17V Industry stage:-35 to +55 ;Commercial stage -5 to V; (keep 10min) 14.4V; (keep 10min) Float charge voltage 13.6V charge return voltage 13.2v Temperature compensation -5mv/ /2v(Boost charge, Direct charge, Float charge, charge return voltage); Lower voltage indicate 12.0V Over discharge voltage Over discharge return voltage Over-discharge pressed return voltage DC Control mode 11.1V(no load)- modified voltage by discharge rate of battery; 2/24V 13.1 V 12.4 V PWM charge mode; modified discharge voltage by the discharge rate Description Rated Power Voltage Using Time Fluorescent lamp 1EA 7 W 12Vdc 50 Hour Radio 1EA 50W 12Vdc 7 Hour 14 Notebook 75W 220Vac 5 Hour 19 Color TV 160W 220Vac 2 Hour Desktop Computer with Monitor 500W 220Vac 1 Hour

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION HIGH VOLTAGE SURGE ARRESTER SPECIFICATION Applications: (Polymer housed MOA for 110kv) (The polymer housed MOA for 10kv) (Porcelain housed MOA for 220kv) (35kv MOA without gaps for middle phase) (110kv

More information

KC5 PV Charge Controller Instruction Manual

KC5 PV Charge Controller Instruction Manual KC5 PV CHARGE CONTROLLER Instruction Manual Ningbo Komaes Solar Technology Co., Ltd. 1.Characteristics 1.1 PWM to prevent power loss. 1.2 Reasonable management for Batteries Charge & Discharge. 1.3 Working

More information

PO Box 2484 Rowville Vic 3178

PO Box 2484 Rowville Vic 3178 www.solar4rvs.com.au info@solar4rvs.com.au 0488 918 910 PO Box 2484 Rowville Vic 3178 1. Primary Functions and Features The Controller provides three primary functions: 1. The Maximum Power Point Tracking

More information

User Manual. Wind and Solar Hybrid Charge Controller 1KW / 2KW 48VDC. HCON Series

User Manual. Wind and Solar Hybrid Charge Controller 1KW / 2KW 48VDC. HCON Series User Manual Wind and Solar Hybrid Charge Controller HCON Series 1KW / 2KW 48VDC Dear Customer, Thank you very much for choosing our product. This manual contains important information about the installation

More information

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv

Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv Type HS PEXLIM-P Surge Arresters Maximum System Voltage 123 kv to 800 kv HS PEXLIM-P Metal Oxide Surge Arrester HS PEXLIM-P Surge Arresters are used for the protection of switchgear, transformers and other

More information

Distribution Arresters

Distribution Arresters Heavy Duty & Riser Pole Ÿ Tested to the latest IEEE C62.11 standards Ÿ High Strength Fiberglass Isolator Brackets Ÿ Ground Lead Disconnect will operate with a minimum of 1 amp Ÿ Protective Cap RUS APPROVED

More information

GROUP D. Switch & Protective device.

GROUP D. Switch & Protective device. GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated

More information

High Voltage Surge Arresters Station Class

High Voltage Surge Arresters Station Class Power Transmission and Distribution High Voltage Surge Arresters Station Class Product Overview High Voltage High Protection Just as the Golden Gate Bridge has successfully defied all winds, weather and

More information

LS0512 Solar Charge Controller

LS0512 Solar Charge Controller LandStar LS0512 Solar Charge Controller Nominal system voltage Maximum PV input voltage Nominal charge / discharge current 12VDC 35V 5A Contents 1 Important Safety Information... 1 2 General Information...

More information

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL EPSOLAR LS1024BP/ LS2024BP Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation, use

More information

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv

Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv Type POLIM-S Surge Arresters Maximum System Voltage 2.52 to 245 kv POLIM-S Metal Oxide Gapless Surge Arresters POLIM-S Surge Arresters are used for the protection of switchgear, transformers and other

More information

USER MANUAL MPS 1-5KW SERIES

USER MANUAL MPS 1-5KW SERIES USER MANUAL MPS 1-5KW SERIES Low Series Frequency Solar and Wind Power Charging Inverter CONTENTS 1 WWW.NEXTGENNRG.COM 1. Introduction... 3 2. Profile Structure 4 2.1. Working Principle 4 2.2.Product Features..5

More information

LS0512R Solar Light Controller

LS0512R Solar Light Controller LandStar LS0512R Solar Light Controller Nominal system voltage Maximum PV input voltage Nominal charge / discharge current 12VDC 35V 5A Contents 1 Important Safety Information... 1 2 General Information...

More information

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL EPSOLAR LS1024BP/ LS2024BP Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation, use

More information

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product.

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product. User s Manual Wind/Solar Hybrid Street Light Controller Please Read This Carefully Prior to Installation and Operation of This Product. 2012 Version: 1.0 1. Product Introduction The wind/solar hybrid street

More information

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER

12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER 12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER P/No.s SC320 & SC330 WARNING Please read these instructions completely prior to installation. Lead acid batteries can be dangerous. Ensure no sparks or flames

More information

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL 10A / 15A / 20A Solar Charge Controller PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL Dear Customer, Thank you very much for choosing our product. This manual contains important information about

More information

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION Surge Arresters UltraSIL Housed VariSTAR Station Class Surge Arresters Electrical Apparatus 235-88 GENERAL Cooper Power Systems has set a new standard of excellence for polymerhoused station class surge

More information

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV December, 1975 New nformation and Supersedes DB 38-131 Pages 1-4, dated May 1972, and 38-121 D WE A, Pages 1-4, dated April1974 E, D, C/1981/ DB Westinghouse Electric Corporation Distribution Apparatus

More information

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter Outdoor Distribution (5 kv through 25 kv) S&C Fault Tamer Fuse Limiter Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles

More information

Solar Inverter 3kW-8kW Inverter (off-grid)

Solar Inverter 3kW-8kW Inverter (off-grid) Solar Inverter 3kW-8kW Inverter (off-grid) Max. DC Power Data: 5.67kW-11.52kW Max. DC Voltage: 200V-400V Max. AC Power: 3kW-8kW Output AC Voltage: 220V (Range: 209-231V) Frequency: 50, 60Hz (49.5-60.6Hz)

More information

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv)

S&C Fault Tamer Fuse Limiter. Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter Outdoor Distribution (5 kv through 25 kv) Introducing S&C s new generation of pole-top transformer protection... Application Although the S&C Fault Tamer Fuse Limiter handles

More information

Solar Inverter Manual

Solar Inverter Manual Solar Inverter Manual Introduction SMPS series solar inverter power charging efficiency increased by 30%~60% than traditional controller charging. This inverter has automatic identification, three-stage

More information

EE 741 Over-voltage and Overcurrent. Spring 2014

EE 741 Over-voltage and Overcurrent. Spring 2014 EE 741 Over-voltage and Overcurrent Protection Spring 2014 Causes of Over-voltages Lightning Capacitor switching Faults (where interruption occurs prior to zero current crossing) Accidental contact with

More information

Duo Battery Charge Controller

Duo Battery Charge Controller Duo Battery Charge Controller RENOGY 10A 20A Pulse Width Modulation Solar Charge Controller Manual 1 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678 Version: 1.2 Important Safety Instructions

More information

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0 PRO POWER 2 0 A L I T H I U M B AT T E RY C H AR G E R M O D E L : P P - L B C - 1 2 2 0 V E R S I O N : V 1. 0 Contents 1. Revised History... 1 2. Warning... 1 3. Notes... 1 4. Product Number System...

More information

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description Type L Cutouts UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout Electrical Apparatus 327-30 Description Cooper Power Systems has set a new standard of excellence for polymer distribution

More information

Solar Power System. User Manual

Solar Power System. User Manual Solar Power System User Manual System introduction The point of the Solar Power System is to replace home power. It is also useful in situations such as: emergencies (rescue and disaster support), no power

More information

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc. DO-III DO-III Fuse Holder TPL 44-835, May 2000, Page 1 of 4 General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder ABB Inc. General Description The ABB DO-III fuse holder is a draw

More information

H U B B ELL L ABOR ATORIES CAPABILITY GUIDE

H U B B ELL L ABOR ATORIES CAPABILITY GUIDE H U B B ELL L ABO R ATO R I E S CAPABILITY GUIDE INTRODUCTION Hubbell Power Systems, Inc. manufactures a wide variety of products for the electric utility, telecommunications, civil construction, transportation,

More information

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv 3EP1 Surge Arrester Metal-oxide surge arrester without series gaps for high-voltage systems up to U m = 170 kv Rated voltage up to 180 kv Nominal discharge current 10 ka, 8/20 µs Line discharge class LD1,

More information

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV The recloser you want, all in one package. Single- and Three-Phase, 15 38kV The need for automated reclosers has never been greater, but many of today s reclosers come with penalties. They weigh too much,

More information

The wind/solar hybrid controller is control device which can control wind turbine and solar panel at the same time and

The wind/solar hybrid controller is control device which can control wind turbine and solar panel at the same time and I. PRODUCT INTRODUCTION The wind/solar hybrid controller is control device which can control wind turbine and solar panel at the same time and transform wind and solar energy into electricity then store

More information

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3. CONTENTS About the company 4 1. Low-voltage arresters LVA type 5 2. Metal-oxide surge arresters for distribution systems. 6 2.1 PA-DM type 6 Dimensions of arresters of PA-DM 9 2.2 PA-DH types 10 Dimensions

More information

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR MB-3688 120A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR User Manual Warning and Precautions MB-3688 is built with corrosion resistant material and the main electronic assembly is well sealed inside

More information

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

ST - II Series POWER SUPPLIES USER INSTRUCTIONS Introduction ST - II Series POWER SUPPLIES These instructions detail the installation and operation requirements for the ST20-II & ST35-II power supplies. These have been designed for operation in RV s

More information

MEDIUM VOLTAGE NETWORKS

MEDIUM VOLTAGE NETWORKS MEDIUM VOLTAGE NETWORKS LIGHTNING ARRESTERS & INSULATORS SICAME GROUP OUR EXPERIENCE With 25 years of experience in the field of over protection for medium lines, DERVASIL designs and manufactures zinc

More information

Don't let the shadows of yesterday hide the sunshine of tomorrow Nandina Morris

Don't let the shadows of yesterday hide the sunshine of tomorrow Nandina Morris Don't let the shadows of yesterday hide the sunshine of tomorrow. -------------- Nandina Morris Hybrid MPPT Solar Inverter Main Features Pure sine wave inverter Built-in MPPT solar charge controller Selectable

More information

TP-BC AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual. DC power output 8A Charge current 7.5A

TP-BC AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual. DC power output 8A Charge current 7.5A TP-BC24-300 AC to DC24V UNINTERRUPTED POWER SUPPLY User Manual Specifications and Features: 210W Total Max. DC power output 8A Max. @24V Charge current 7.5A Max. @28V Net weight, only 4.63 lbs/2.1kg Dimensions

More information

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION 92 Section VI. Schedule of Requirements 7.0 Technical Guarantee Specification of 60MV, 132/33 Mobile Substation TECHNICL DT SCHEDULE 60MV, 132/33 MOBILE SUBSTTION ITEM DESCRIPTION UNITS REQUIRED GURNTEED

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Battery 12V battery system 24V battery system Type Type Code Bulk Floating Bulk Floating Vented 01 14.3 V 13.2 V 28.6 V 26.4 V Sealed 02 14.3 V

More information

Solar Charge Controller

Solar Charge Controller Table 3: Charging voltage for 4 types of battery Battery Type Battery Type Code SC-600W MPPT Bulk Voltage Floating Voltage Vented 01 28.6 V 26.4 V Sealed 02 28.6 V 26.8 V Gel 03 28.6 V 27.4 V NiCd 04 28.6

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Solar Charge Controller Quick Guide 200W 300W 400W 600W 850W V. 2.2 1. Introduction solar charge controller uses PWM-based DSP controller to keep the batteries regulated and prevent batteries from overcharging

More information

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified Surge s Catalog Data CA235022EN Supersedes TD235009EN September 2014 COOPER POWER SERIES VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified General Eaton s Cooper

More information

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) GENERIC TECHNICAL DATA Maximum system voltage U m 800 System voltage U s 750 Nominal discharge current ka 20 High current impulse (4/10 µs) ka 100 Arrester class

More information

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller Table 4: Alarm point for low battery voltage table Model Alarm point SCC-MPPT-300 10.5 V SCC-MPPT-600 21.0 V Table 5: Charging hour table for reference Battery Capacity To 90% capacity @ 25A charging current

More information

Figure 1. HX cutout fuseholders.

Figure 1. HX cutout fuseholders. Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus K-SEC 010 GENERAL Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted

More information

Owner s Manual. Advanced Wind/Solar Hybrid (Street Light) Controller

Owner s Manual. Advanced Wind/Solar Hybrid (Street Light) Controller Owner s Manual Advanced Wind/Solar Hybrid (Street Light) Controller 1. General Description The advanced wind/solar hybrid controller is specially designed for high-end small-scale wind/solar hybrid system

More information

Surge Arrester 3EL2 superior protection up to 550 kv

Surge Arrester 3EL2 superior protection up to 550 kv Certified according to IEC 60099-4 Edition 2.1 (2006) Surge Arrester 3EL2 superior protection up to 550 Light weight. Strong performance. Answers for energy. Simply irresistible. By resisting wear in any

More information

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Solid Dielectric, Three Phase Reclosers CATALOG VS11 Solid Dielectric, Three Phase Reclosers Providing electronic, three phase overcurrent protection for systems rated through 38kV, 800A continuous current, 12.5kA symmetrical interrupting Reliable performance

More information

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC

BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) ENERGY /// MCA/MDA SURGE ARRESTERS IEC BOWTHORPE EMP MCA/MDA SURGE ARRESTERS (IEC) GENERIC TECHNICAL DATA MCA MDA Maximum system voltage U m 420 550 System voltage U s 400 500 Nominal discharge current ka 10 20 High current impulse (4/10 µs)

More information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV) Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82314 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.

More information

Suitcase solar power system

Suitcase solar power system Suitcase solar power system 一 Product features 1. This system with microprocessor and special control algorithm to make intelligent control into reality. Which is a nice power system for outdoor working,

More information

34-SDMS-01 SPECIFICATIONS FOR

34-SDMS-01 SPECIFICATIONS FOR SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES

More information

Figure 1. HX cutout fuseholders. Positive Interruption

Figure 1. HX cutout fuseholders. Positive Interruption Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus 327-10 general Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted to

More information

Domae. The right solution for distribution boards

Domae. The right solution for distribution boards Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:

More information

3EQ Composite Housed Surge Arresters

3EQ Composite Housed Surge Arresters Power Transmission and Distribution 3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability A perfect Combination of Cost-Savings, Safety and Reliability 3EQ Surge Arresters: Your

More information

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating Fusing Equipment Edison Links Electrical Apparatus K-SEC 100 GENERAL Cooper Power Systems Kearney line of fuse links, Edison Links, can be applied to a variety of applications requiring overcurrent protection

More information

شركة كهرباء محافظة القدس المساهمة المحدودة

شركة كهرباء محافظة القدس المساهمة المحدودة Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories

More information

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER USER MANUAL βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER (OPTIONAL) CHARACTERISTICS LCD display: all systems parameters

More information

Directly Molded Polymer Surge Arresters

Directly Molded Polymer Surge Arresters Directly Molded Polymer Surge Arresters Ideal means to reduce environmental impact Up to 420kV, Comply with IEC60099-4, Line discharge class 2-4 l Long-life performance (Hydrophobic silicone rubber) l

More information

PRODUCT CATALOGUE. Overhead System

PRODUCT CATALOGUE. Overhead System PRODUCT CATALOGUE Overhead System Information Tel : 03-4777547 Fax : 03-4777570 E-mail : overseas@jaker.com.tw Web : www.jaker.com.tw Add : No.787, Xinwen Rd. Xinwu Dist., Taoyuan City 327, Taiwan Contents

More information

EPEVER. LS-E Series. Solar Charge Controller USER MANUAL

EPEVER. LS-E Series. Solar Charge Controller USER MANUAL EPEVER LS-E Series Solar Charge Controller USER MANUAL LandStar LS-E Series Solar Charge Controller Nominal System Voltage Maximum PV Input Voltage Nominal Charge/Discharge Current LS0512E/LS1012E LS1024E/LS2024E

More information

3EK7 Medium Voltage Silicone Insulated Surge Arresters

3EK7 Medium Voltage Silicone Insulated Surge Arresters 3EK7 Medium Voltage Silicone Insulated Surge Arresters Power Transmission and Distribution Setting new Standards The 3EK7 s mechanical features: Glass-collared MOV, Silicone rubber housing, FRP rods and

More information

3EP6 porcelain surge arrester

3EP6 porcelain surge arrester www.siemens.com/energy/arrester 3EP6 porcelain surge arrester Safe, reliable, long-lasting, and stable Answers for energy. Compact design high mechanical stability Sealing system Spring Maximum values

More information

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka) Surge s UltraSIL Polymer-Housed VariSTAR Surge s: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka) Electrical Apparatus 235-35 General Cooper Power Systems has set the standard

More information

Product Group Brochure. PS Range Capacitor Vacuum Switches

Product Group Brochure. PS Range Capacitor Vacuum Switches Product Group Brochure PS Range Capacitor Vacuum Switches Introduction ABB introduces the latest range of PS capacitor vacuum switches. Building on the proven PS switch design, new single phase and three

More information

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) M-RING 24 SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A) Contents General Description Advanced facilities and process Advanced design philosophy Definition of M-RING 24 Standards Service conditions

More information

Technical Specification for Pole Mounted Capacitor Rack

Technical Specification for Pole Mounted Capacitor Rack Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to

More information

1 Phase electronic contactor (SC 1)

1 Phase electronic contactor (SC 1) 1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Fusing Equipment Catalog Data CA132035EN Supersedes November 2015 COOPER POWER SERIES UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout Description Eaton has set a standard

More information

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required! DB 750-205 January 2007 Supercedes: December 2006 Now available with Vacuum Interrupter Monitor VBT Switch 15kV - 69kV VBU-T Switch 69kV - 230kV Longest Life Product for Electric Furnace Applications!

More information

GENERAL. CONSTRUCTION External

GENERAL. CONSTRUCTION External Surge Arresters VariSTAR Type AZG4 Surge Arresters for Systems through 400 kv IEC 20-kA; Line Discharge Class 4 Electrical Apparatus I235-84 GENERAL VariSTAR AZG4 Surge Arresters incorporate the latest

More information

Protection and Disconnection Equipment for High and Medium Voltage and Transformers Line

Protection and Disconnection Equipment for High and Medium Voltage and Transformers Line Protection and Disconnection Equipment for High and Medium Voltage and Transformers Line IUSA is present in Mexico, Europe, Asia, the US, Central and South America. Established in 1939. Workforce of over

More information

SPECIFICATIONS LOW COST 2404R CHARGER

SPECIFICATIONS LOW COST 2404R CHARGER SPECIFICATIONS LOW COST 2404R CHARGER Totally Automatic Switch-Mode Battery Chargers "Suitable for Gel, Sealed & Wet Lead Acid Batteries" Summary: 24 Volts, 2 Amp Constant Current (Equivalent to 4A tapered

More information

Elite Pure Sine. DC To AC Power Inverters Convert 12V DC electricity into clean household-like power.

Elite Pure Sine. DC To AC Power Inverters Convert 12V DC electricity into clean household-like power. Elite Pure Sine DC To AC Power Inverters Convert 12V DC electricity into clean household-like power. Elite Pure Sine Inverters Size Comparison (20% scale) 5000W 3000W 1500W & 2000W Pure Sine Wave Modified

More information

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION Fusing Equipment Tandem ELF Current-Limiting Dropout Fuse Electrical pparatus 240-67 GENERL The Cooper Power Systems Tandem ELF current-limiting fuse is designed for transformer protection. The Tandem

More information

Eclipse Solar Suitcase

Eclipse Solar Suitcase Eclipse Solar Suitcase Renogy 100W 200W 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.0 Important Safety Instructions Please save these instructions. This manual contains important

More information

SPECIFICATIONS CAA Supercharger

SPECIFICATIONS CAA Supercharger SPECIFICATIONS - 2408CAA Totally Automatic Switch-Mode Battery Chargers "Suitable for Gel, Sealed & Wet Lead Acid Batteries" Summary: 24 V, 4A Constant Current (equivalent to 8A tapered charger in charging

More information

KC3 PV Charge Controller Instruction Manual

KC3 PV Charge Controller Instruction Manual KC3 PV CHARGE CONTROLLER Instruction Manual Ningbo Komaes Solar Technology Co., Ltd. 1.Characteristics 1.1 PWM to prevent power loss 1.2 Reasonable management for Batteries Charge & Discharge. 1.3 Four

More information

POLYMER INSULATOR. Index

POLYMER INSULATOR. Index POLYMER INSULATOR Index INTRODUCTION...2 IEC COMPOSITE INSULATORS...7 ANSI COMPOSITE INSULATORS...14 Introduction General This new generation of Polymer Insulator characterized with: Small Light High mechanical

More information

Silicone Suspension/Tension Insulator 120kN. up to LIWV 450kV (BIL)

Silicone Suspension/Tension Insulator 120kN. up to LIWV 450kV (BIL) Silicone Suspension/Tension Insulator 120kN up to LIWV 450kV (BIL) CABLE SYSTEMS FOR ENERGY & ROLLING STOCK APPLICATIONS MV Silicone Tension Insulators The high tensile strength of glass fibre has been

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

3EK7 Distribution Class Surge Arresters. Answers for energy.

3EK7 Distribution Class Surge Arresters. Answers for energy. 3EK7 Distribution Class Surge Arresters Answers for energy. Siemens at Your Service As a global leader of the electronics industries, Siemens has been active in the fields of power transmission and distribution

More information

SPECIFICATIONS SRF SuperchargerPlus

SPECIFICATIONS SRF SuperchargerPlus SPECIFICATIONS - 2412SRF Totally Automatic Switch-Mode Battery Chargers "Suitable for Gel, Sealed & Wet Lead Acid Batteries" Summary: 24 V, 6Amp Constant Current (equivalent to 12A tapered charger in charging

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance [ ] There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing

More information

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze

More information

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13. MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. - 1 - Table of Contents 1. SALIENT FEATURES...3 2.. PRODUCT INSTALLATION & PRECAUTIONS...3 2.1. PRODUCT INSTALLATION &

More information

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability

3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability 3EQ Composite Housed Surge Arresters Saving Money and Space, Gaining Reliability Power Transmission and Distribution 1 A perfect Combination of Cost-Savings, Safety and Reliability 3EQ Surge Arresters:

More information

LS1024R / LS1524R / LS2024R. Solar Light Controller INSTRUCTION MANUAL

LS1024R / LS1524R / LS2024R. Solar Light Controller INSTRUCTION MANUAL EPSOLAR Design patent NO.: 201130028317.3 Utility model patent NO.: 201120064092.1 LS1024R / LS1524R / LS2024R Solar Light Controller INSTRUCTION MANUAL Thank you very much for selecting our product! This

More information

K-Limiter high ampere Companion II fuse

K-Limiter high ampere Companion II fuse Fusing Equipment Catalog Data CA132059EN Supersedes February 2016 COOPER POWER SERIES K-Limiter high ampere Companion II fuse General Eaton designs its Cooper Power series K-Limiter fuse to be conveniently

More information

USER MANUAL. Insulation Tester + DMM. Model MG320

USER MANUAL. Insulation Tester + DMM. Model MG320 USER MANUAL Insulation Tester + DMM Model MG320 Table of Contents 1. INTRODUCTION 3 2. SAFETY 3 3. METER DESCRIPTION 5 4. CONTROL BUTTONS 6 5. SYMBOLS AND ANNUNCIATORS 6 6. OPERATING INSTRUCTIONS 7 6.1

More information

True RMS Autoranging Multimeter

True RMS Autoranging Multimeter Owner's Manual True RMS Autoranging Multimeter Model No. 73754 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

Manual Installation & Operation

Manual Installation & Operation Manual Installation & Operation Model: NCxxLxx 12A or 30A Solid State Solar Charging Regulator and 12A Load Controller. 231 Patent #: 5,642,030 Applies Page 1 Warnings When Installing, connect grounds,

More information

MANBLAN Hybrid Powered Landscape Lights SL C-00-5 <Assembly Type>

MANBLAN Hybrid Powered Landscape Lights SL C-00-5 <Assembly Type> MANBLAN Hybrid Powered Landscape Lights SL03-13024C-00-5 1 MANBLAN Hybrid Powered Landscape Lights SL03-13024C-00-5 INDEX 1. Design Overview 3-4 2. Wind Turbine 5 3. Solar Panel 6 4. LED

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Safety technique. Emergency Stop Module BH 5928, BI 5928

Safety technique. Emergency Stop Module BH 5928, BI 5928 Safety technique Emergency Stop Module BH 5928, BI 5928 with time delay safemaster 0226419 Function diagram According to EU directive for machines 98/37/EG According to IEC/E 60 204, E 954-1 Safety category

More information

SPECIFICATIONS SRF

SPECIFICATIONS SRF 6033 Shawson Dr., Unit 29, Mississauga Ontario, Canada L5T 1H8 e-mail: info@soneil.com Ph.: 905 565 0360 Fax: 905 565 0352 Visit us on the web at www.soneil.com SPECIFICATIONS - 2416SRF Totally Automatic

More information

General Precautions. Personnel Precautions

General Precautions. Personnel Precautions USER MANUAL General Precautions 1. Before using Inverex, read all instructions and cautionary markings on : (1) Inverex (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only

More information