COMPONENTS. Multi-functional Main AC Switch for rolling stock Type MACS

Size: px
Start display at page:

Download "COMPONENTS. Multi-functional Main AC Switch for rolling stock Type MACS"

Transcription

1 COMPONENTS Multi-functional Main AC Switch for rolling stock Type MACS

2 GENERAL INFORMATION MACS is a platform for Main AC Switch installed on electric rail vehicles running on AC networks. The AC vacuum Circuit-Breaker (AC VCB), which is the core function of the assembly, can be combined on the same base plate with other functions, such as Earthing Switch (), Surge Arrester (SA), Roof Switch (RS), offering the car builders the most modular platform, particularly well adapted to match their different applications and requirements. MACS can be mounted either vertically on the vehicle s roof of EMUs and Trains as well as inside traction container for locomotives. Another option is horizontally inside Sécheron s high voltage modular compact enclosure, AC MODBOX, to be installed on the roof- or under the frame of trains. APPLICATIONS Switching and protection of main and auxiliary electric circuits for locomotives, trains and EMUs running on 15 kvac or/and 25 kvac networks. MACS is a fully electrically operated circuit-breaker, designed to automatically open through spring release in case the low supply voltage is interrupted. This fail-safe concept is a key safety issue for rolling stock circuitbreakers, equipped with electric or electro-pneumatic operation. MACS platform with its small dimensions and light weight, completed with the compact and modular AC AC MODBOX, which integrates MACS in an aluminium housing with other high voltage functions such as current and voltage measurements, disconnect switch, fi lters, transient inductors, is the perfect solution for your rolling stock material running on 15 kvac or/and 25 kvac networks. MAIN FEATUR Compact multi-functional switch including: AC circuit-breaker, earthing switch (option) and surge arrester (option) on a single support of 940 mm x 430 mm. /// AC CIRCUIT-BREAKER Suitable for 15 kvac and/or 25 kvac networks Conventional free air thermal current: 1000 A Rated impulse withstand voltage (1.2 / 50 µs): Uimp = 125 kv or 170 kv External creepage distances > 1000 mm Vacuum interrupter Electric operation (closing and holding) Usable in various ranges of ambient temperature from -40 C to +70 C (-50 C to +70 C in option) Reference standards: IEC /-2 /-4, IEC61373, EN , NF F /-102 /// EARTHING SWITCH Optional integrated earthing switch with manual or electric operation Safe manual operation guaranteed by optional interlocking keys Ice breaking capability (20 mm ice) /// SURGE ARRTER Optional integrated surge arrester r (to be defi ned by Sécheron upon customer s specifi cations) MAIN BENEFITS Indoor or outdoor installation Vertical or horizontal mounting High safety thanks to the automatic opening through spring release in case of interruption of supply voltage (no need of stored auxiliary electrical energy Compliant to LOC & PAS TSI (Technical specification for interoperability), 1302/2014/EU. High mecanical durability: > operations Low height: 563 mm (for Uimp = 125 kv) above the roof and 140 mm below the roof Low weight: < 100 kg for the AC circuit-breaker MAIN BENEFITS 2 AC CIRCUIT-BREAKER FOR ROLLING STOCK, TYPE MACS

3 DATA FOR PRODUCT SELECTION MAIN HIGH VOLTAGE CIRCUIT AC circuit-breaker Symbol Unit 15 kv 25 kv Rated operational voltage Ue [VAC] (1) (1) Rated insulation voltage Ui [VAC] (1) (1) Rated operational current Ie [A] Conventional free air thermal current (2) Ith [A] Rated operational frequency f [Hz] , 60 Operational category C3 C3 Peak short-circuit making current IMC [ka] Rated short-circuit breaking current / % value of the DC component [ka]/% 25/50 20/50 Peak and rated short-time withstand current (1 s) Îcw/Icw [ka]/[ka] 63/25 63/25 Short-time withstand currents 100 ms Icw Rated power-frequency withstand voltage (50 Hz, 1 mn) U50 [kvrms] Rated impulse withstand voltage (1.2/50 µs) Uimp [kv] /170 (1) For higher values, please contact Sécheron. (2) At Tamb = +40 C and tested with high voltage connections according to standard IEC/EN Earthing switch Peak and rated short-time withstand current Îcw/Icw/t [ka]/[ka]/[s] 63/25/1 63/25/1 LOW VOLTAGE AUXILIARY CIRCUIT Control circuit AC circuit-breaker Nominal voltage (power supply and control order) Un [Vdc] 24 to 110 Range of voltage (power supply and control order) [ ] Un Maximum power (loading and holding) (3) (4) Pmax [W] 100 Nominal holding power (4) Ph [W] 35 Opening power [W] 0 Mechanical opening time (4) To [ms] 50 Mechanical closing time (4) Tc [ms] 65 Earthing switch (optional electric operation) Nominal voltage Un [Vdc] 24, 32, 36, 48/50, 72, 110 Operating power (4) [W] 125 Commutation time (4) [s] 3 (3) Loading time < 12 seconds. (4) At Un and Tamb = + 20 C. Auxiliary contacts Type of contacts (5) Potential free Rated voltage [VDC] 24 to 110 Conventional thermal current Ith [A] 10 Switching categories according to EN60947 (silver contacts) - AC VAC 1.0 A - DC VDC 0.5 A Minimum let-through current at 24 VDC (6) [ma] 10 (silver contacts) or 4 I < 10 (gold contacts) (5) Refer to page 6. (6) For a dry and clean environment. Low voltage interface Type of connection (7) - AC VCB with or without manual earthing switch 1 Connector: Harting 51 P - AC VCB with electric earthing switch 2 Connectors: Harting 51 P + Harting 24 DD (7) Refer to page 7 for mobile connector information. Insulation Rated power-frequency withstand voltage (50 Hz, 1 mn) U50 [kvrms] 1.5 OPERATING CONDITIONS Installation Indoor or outdoor Altitude [m] < 1400 Working ambient temperature Tamb [ C] -40 to +70 / -50 to +70 Humidity Class 5K2 Pollution degree PD4 Minimum mechanical durability N [Cycles] AC CIRCUIT-BREAKER FOR ROLLING STOCK, TYPE MACS 3

4 PRODUCT INTEGRATION MAIN DIMENSIONS Dimensions without tolerances are indicative. All dimensions are in mm. The maximum allowed flatness deviation of the support frame is 0.5 mm. and earth connections: M12 screws. /// AC CIRCUIT-BREAKER 15 KVAC AND 25 KVAC Weight: Refer to the table below Uimp [kv] A B kv 25 kv 25 kv A (mm) B (mm) Weight (kg) 90 ±3 90 ±3 91 ±3 15 Frame level > Roof opening and frame dimensions x M12 >940 MOUNTING POSSIBILITI /// VERTICAL MOUNTING ON THE ROOF /// HORIZONTAL MOUNTING ON THE ROOF Underframe mounting or roof mounting in special high voltage box (Sécheron AC MODBOX ) 4 AC CIRCUIT-BREAKER FOR ROLLING STOCK, TYPE MACS

5 LOW VOLTAGE WIRING DIAGRAM (HARTING HAN MODULAR 51-PINS CONNECTOR) Legend of the schemes: Circuit-breaker main contacts Low voltage connector interface (male pin) Earthing switch main contacts a b 1a + 1b - switch PF Closing coil Earthing switch manual operation The bellow scheme represents MACS standard configuration (4a+4b switch PF), with optional additional auxiliary switches (4a+4b switch PF) and optional manual earthing switch (2a+2b switch PF). For electric earthing switch, please contact Sécheron. c1 c2 c7 c8 c3 B + B - O + O - R Control Unit MACS a7 a1 a9 a14 A B C D E a8 a2 a3 a12 a4 a13 a10 a15 a5 a16 a6 a17 b1 b7 b2 b8 b12 b3 F b13 b4 b14 b9 G b15 b10 b16 b5 H b17 b6 c9 c14 Ra Rb c4 c5 c6 c15 B : Battery power supply O : Control order R : Ready switch (MACS ready to close) : Earthing switch : Optional auxiliary contacts I c16 c10 J c11 c17 a b c AC CIRCUIT-BREAKER FOR ROLLING STOCK, TYPE MACS 5

6 OPTIONS (SUBJECT TO ADDITIONAL COSTS) AC CIRCUIT-BREAKER 15KVAC& 25 KVAC (Uimp=125 KV or 170 KV) AND EARTHING SWITCH Electric version (option) Manual version (standard) Weight: AC circuit-breaker + 13 kg (manual version) AC circuit-breaker + 20 kg (electric version) (170 kv) 521 (125 kv) * * 220* * (*) Space needed to remove the cover and to operate the optional earthing switch Note : roof opening and frame dimensions for optional configuratopn are the same as for standard configuration. AC CIRCUIT-BREAKER AND SURGE ARRTER AC VCB SA2 Overhead line 15 or 25 kvac SA1, SA2: surge arresters AC VCB: AC vacuum circuit-breaker : earthing switch SA1 For a safe and effi cient protection of the vehicle s high voltage circuits against ligthning and switching overvoltages, Sécheron strongly recommends to use two surge arresters SA1 and SA2 in the high voltage circuit of the vehicle. In order to protect effi ciently the AC circuit-breaker, the distance between each surge arrester and the AC circuit-breaker must not exceed 15 meters. Should the customer want to integrate one surge arrester to the MACS, he can rely on Sécheron s specialists to defi ne the appropriate type. /// AC CIRCUIT-BREAKER AND SURGE ARRTER CONNECTIONS Surge arrester connections: M12 screws. 424 The connection between the ac circuit-breaker and the surge arrester is not represented on the drawing but is available in the scope of supply from Sécheron. Weight and Height of surge arresters depend on selected type 15 6 AC CIRCUIT-BREAKER FOR ROLLING STOCK, TYPE MACS

7 LV MOBILE CONNECTOR FOR AC CIRCUIT-BREAKER (SEPARATELY ORDERED ITEM) MACS configurations Auxilliary Switches Fixed connector Number of pin Size Size Device (1) Number Type (2) type Type 2.5 mm mm 2 Mobile connectors Cable gland Cable entry Secheron s number AC circuit-breaker without earthing switch Case 1 AC VCB 4a + 4b PF 3 21 M25 SG325249R00101 SG325249R00201 Case 2 AC VCB 8a + 8b PF 3 37 M32 SG325249R00302 SG325249R00402 AC circuit-breaker with manual earthing switch Case 3 AC VCB + 4a + 4b 0a + 0b PF 3 21 M25 SG325249R00101 SG325249R00201 Case 4 AC VCB + 4a + 4b 2a + 2b PF 3 29 M32 SG325249R00303 SG325249R00403 Case 5 AC VCB + 8a + 8b 0a + 0b PF 3 37 M32 SG325249R00302 SG325249R00402 Case 6 AC VCB + 8a + 8b 2a + 2b PF 3 45 M32 SG325249R00304 SG325249R00404 AC circuit-breaker with electric earthing switch In this case the customer shall buy a second LV mobile connector for the electric earthing switch, additionally to the LV mobile connector of the AC circuit-breaker (case 1 or 2). Case 7 2a + 2b PF Harting HAN 24 DD Harting HAN 24 DD 2 12 M25 SG325249R00521 SG325249R00520 (1) AC VCB: AC Vacuum Circuit-Breaker : Earthing Switch. (2) PF: Potential Free. Notes: Harting Han Modular 51 pins connector is made of 3 Harting HAN DDD17 modules (each module supplied with 17 pins). The above references are given for mobile connectors considering that all the auxiliary contacts are wired, with an external wire diameter of 2.8 mm for a copper section of 2.5mm² and 2.3 mm for a copper section of 1.5 mm². If the conditions are different from these, the above references may change. In such case please inform Sécheron accordingly. AC CIRCUIT-BREAKER FOR ROLLING STOCK, TYPE MACS 7

8 DIGNATION CODE FOR ORDERING Be sure to establish the designation code from the latest version of our brochure by downloading it from the website: Be careful to write down the complete alphanumerical designation code with 11 characters when placing your order For technical reasons some variants and options indicated in the designation code might not be combined For other confi gurations not described in the brochure, please contact Secheron. Example of customer s choice: M 4 A 1 A E A B Z Z 1 Line: The bold characters of the designation code defi ne the device type. DIGNATION CODE Line Description Designation Standard Options Customer s choice 10 Product type MACS M M 11 Nominal voltage 15 kv or 25 kv (Uimp = 125 kv) 4 25 kv (Uimp = 170 kv) 3 12 Mechanical interface Standard base plate / vertical mounting A A 13 Earthing switch No 0 Yes (with manual operation) 1 Yes (with electric operation) 2 14 Surge arrester No 0 Yes - For surge arrester type and code, please contact Sécheron Control voltage 24 VDC A 32 VDC F 36 VDC B 48 VDC / 50 VDC C 72 VDC D 110 VDC E 16 Auxiliary contacts on the AC circuit-breaker 4a + 4b - (switch PF) - silver type A 4a + 4b - (switch PF) - gold type C 8a + 8b - (switch PF) - silver type B 8a + 8b - (switch PF) - gold type D 17 Auxiliary contacts on the earthing switch (No earthing switch) Not applicable Z None (1) 0 2a + 2b - (switch PF) - silver type H 2a + 2b - (switch PF) - gold type C 18 Interlocking keys for earthing switch (Electric operation or no earthing switch) Not applicable Z No key / lock 0 1 blue (master) + 1 yellow (slave) B 1 blue (master) + 2 yellow (slave) C 2 blue (master) + 1 yellow (slave) F 1 yellow (master) + 1 green (slave) H 1 yellow (master) + 2 green (slave) I 2 yellow (master) + 1 green (slave) L Key / locks delivered by customer S 19 Key and lock codification for each unit (Electric operation or no earthing switch) Not applicable Z No 0 Yes 1 20 Ambient temperature range -40 C to +70 C 1-50 C to +70 C 2 (1) For manual switch only. The low voltage connector must be ordered separately (refer to page 7). Place and date: Name: Signature: - LV mobile connector for the AC circuit-breaker with or without manual earthing switch: SG325249R00101 SG325249R00201 SG325249R00302 SG325249R00303 SG325249R00304 SG325249R00402 SG325249R00403 SG325249R Additional LV mobile connector for the electric earthing switch: SG325249R00521 SG325249R00520 This document is not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the right to modify and/or improve the product, whose characteristics are described in these documents, as required by new technology at any time. It is the purchaser s responsibility to inform himself, no matter what the circumstances, of the product s maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our General Delivery Conditions. Copyright 2018 Sécheron SA Sécheron SA Rue du Pré-Bouvier Satigny - Geneva CH-Switzerland Tel: Fax: info@secheron.com SG325101BEN_E

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

COMPONENTS. Off-load Switch for Fixed Installation Title type SW COMPONENTS Off-load Switch for Fixed Installation Title type SW General information The SW off-load switch is a complete range designed to cover all the applications to be met in DC traction power substations

More information

COMPONENTS. High-speed DC circuit-breakers for Rolling Stock Type UR6, UR10 & UR15

COMPONENTS. High-speed DC circuit-breakers for Rolling Stock Type UR6, UR10 & UR15 OMPONNT Highspeed circuitbreakers for Rolling tock Type UR, UR & UR General information UR, UR and UR are highspeed current limiting circuitbreakers with natural cooling, trip free, single pole, bidirectional,

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

COMPONENTS / SUPPLY PROGRAM FOR RAIL TRANSPORTATION

COMPONENTS / SUPPLY PROGRAM FOR RAIL TRANSPORTATION COMPONENTS / SUPPLY PROGRAM FOR RAIL TRANSPORTATION Sécheron SA, member of the Sécheron Hasler Group, is one of the world leaders for the design, manufacturing and supply of components and systems, for

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650515200 Ed.1 of 21/02/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650523200 Ed.1 of 23/07/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Outdoor vacuum breaker for railway applications - FSK II

Outdoor vacuum breaker for railway applications - FSK II Outdoor vacuum breaker for railway applications - FSK II Single or two-pole outdoor vacuum breaker with magnetic actuator 27.5 kv - 250 kv BIL - 1250 A. 2000 A - 25.0 ka - 50/60 Hz 27.5 kv - 200 kv BIL

More information

Surge arrester POLIM-H..SD

Surge arrester POLIM-H..SD Data sheet Surge arrester POLIM-H..SD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work GE Electrical Distribution Gerapid High Speed DC Circuit Breakers On the move imagination at work Gerapid High Speed DC Circuit Breakers To stay up and running today, you need equipment that delivers both

More information

Surge arrester POLIM-H.. ND

Surge arrester POLIM-H.. ND DATA SHEET Surge arrester POLIM-H.. ND Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

Zinc Oxide Surge Arrester EXLIM R

Zinc Oxide Surge Arrester EXLIM R Zinc Oxide Surge Arrester EXLIM R Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. For use when requirements of lightning intensity, energy

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

Surge arrester POLIM-C.. HD

Surge arrester POLIM-C.. HD DATA SHEET Surge arrester POLIM-C.. HD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-A High current impulse I hc (4/10

More information

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en Connect - Contact - Control 3 Contactors CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en 2 CL1115/02, CL1215/02, CL1315/02 1, 2 and 3

More information

T-Switches Range. TL Contactors TS disconnectors TP Contactors. TELARC s multipurpose DC and AC current switches for multiple application.

T-Switches Range. TL Contactors TS disconnectors TP Contactors. TELARC s multipurpose DC and AC current switches for multiple application. TP-PNORM T-Switches Range TL Contactors TS disconnectors TP Contactors TELRC s multipurpose DC and C current switches for multiple application Rolling Stock Energy generation Substation equipment Industrial

More information

Scheda prodotto Relè Series E

Scheda prodotto Relè Series E Relè Miniatura All-or-Nothing relays ideally suited for any electronic appliances demanding very compact design and low power consumption. Design includes a protective dust cover and a completete range

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

SUBSTATIONS. Energy Storage System

SUBSTATIONS. Energy Storage System SUBSTATIONS Energy Storage System ENERGY STORAGE SYSTEM Description The purpose of the Energy Storage System (E.S.S.) is to collect and store energy generated during the braking sequence of a vehicle such

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

B kv Gas-insulated Substations

B kv Gas-insulated Substations 72.5 145 kv Gas-insulated Substations The increasing demand for electrical power in cities and industrial centres requires the installation of a compact and efficient distribution and transmission network.

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

K50F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-50 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K63F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-63 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20.

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20. Connect - Contact - Control Contactors CT5/0, CT0/0 CT5/0, CT0/0 CT5/0, CT0/0, and pole power contactors for AC and DC Catalogue C0.en Power contactors for AC and DC, Series CT Owing to a new blowout technology,

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV Air Insulated Switchgear TAP17. Technical Data TGOOD MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A Characteristics power relay plug-in - Zelio RPF - 2 NO - 120 V AC - 30 A Product availability : Stock - Normally stocked in distribution facility Price* : 12.69 USD Main Range of product Series name Product

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

Zinc-Oxide Surge Arrester TEXLIM Q-C

Zinc-Oxide Surge Arrester TEXLIM Q-C Zinc-Oxide Surge Arrester TEXLIM Q-C Protection of switchgear, transformers and other equipment in high systems against atmospheric and switching overs. in areas with very high lightning intensity where

More information

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control Connect - Contact - Control 3 Contactors CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en More information at: schaltbau-gmbh.com 42 CH1130/02 Single pole high-voltage contactor

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

Single foot switches - PX and PA series

Single foot switches - PX and PA series Single foot switches - PX and PA series Description The PX and PA foot switches are traditional products of Pizzato Elettrica that have recorded a continuous growth and success in the market. Modified

More information

Low Voltage Main Distribution Board

Low Voltage Main Distribution Board s M series... Low Voltage Main Distribution Board Safe and intelligent power distribution Whether in industrial plants, in infrastructure or in buildings, all technical plant depends on the reliable supply

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................

More information

500 / 630 / 720 / 760 / 800 / 850 / 900

500 / 630 / 720 / 760 / 800 / 850 / 900 SUNNY CENTRAL STORAGE 500 / 630 / 720 / 760 / 800 / 850 / 900 SCS 500 / SCS 630 / SCS 720 / SCS 760 / SCS 800 / SCS 850 / SCS 900 Durable Full nominal power in continuous operation at ambient temperatures

More information

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact

More information

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12) s www.siemens.com/energy Auxiliary Relay (7PJ) and Trip Relay (7PJ2) Better protection and more efficiency for your power system Answers for infrastructure and cities. Auxiliary Relay and Trip Relay Catalogue

More information

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key! 655 Door with Key SERIES Related Information General terms and conditions... F-7 General precautions... P.50 PHOTO PHOTO Conforming to Machine & EMC Directives Recognition Certified MEASURE ITY panasonic.net/id/pidsx/global

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

Microswitches MK series

Microswitches MK series Microswitches MK series Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica. These products have been designed with

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

CP Automatic capacitor bank

CP Automatic capacitor bank CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor

More information

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A. SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation 630 3150A SYSclad 12 17,5kV 16 31,5kA Generalities SYSclad is a medium voltage switchboard metal clad

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O Characteristics pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O Product availability : Non-Stock - Not normally stocked in distribution facility Main Range of product Product or component

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1. DISTRIBUTION SOLUTIONS ZX1.5-R Gas-insulated medium voltage for railway application Safety and reliability 20% footprint saving Easy operation Complete solution ZX1.5-R Gas-insulated medium voltage for

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

Medium Voltage Distribution FBX. Gas insulated switchgear up to 24 kv. Technical Characteristics Catalogue 2011

Medium Voltage Distribution FBX. Gas insulated switchgear up to 24 kv. Technical Characteristics Catalogue 2011 Medium Voltage Distribution FBX Gas insulated switchgear up to 24 kv Technical Characteristics Catalogue 2011 A new path for achieving your electrical installations A comprehensive offer The FBX range

More information

Door Interlock Switches

Door Interlock Switches HS5B Series HS5B Series Miniature Interlock Switch HS5B features: mm x mm x 9mm Compact Housing Available with Contact Confi gurations (NO + NC or NC) Flexible Installation: By turning the head of the

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications Protection and Connection -disconnectors OTDC and OTDCP for photovoltaic applications -disconnectors OTDC and OTDCP for photovoltaic applications DC swi-disconnectors Premium performance for DC applications

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Metal Clad Air Insulated Switchgear

Metal Clad Air Insulated Switchgear Metal Clad Air Insulated Switchgear 1/ SecoGear Metal Clad Switchgear Features Fully metal-clad Equipped with Embedded pole VCB Full Front access (can be installed against wall) Perfect interlocking system

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A Quality For You. How simple and functional can a range of moulded-case circuit-breakers be? It was answering this question, which

More information

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ

More information

RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...

More information

FA Off-Load Switches. Up to 8000 A and 3000 V AC/DC Expertly engineered for reliable performance

FA Off-Load Switches. Up to 8000 A and 3000 V AC/DC Expertly engineered for reliable performance F Off-Load Switches Up to 8000 and C/DC Expertly engineered for reliable performance For more than years has been providing safe and reliable solutions for switching and disconnecting high power. High

More information

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED Characteristics universal plug-in relay - Zelio RUM - 2 C/O - 120 V AC - 10 A - with LED Product availability : Stock - Normally stocked in distribution facility Price* : 13.79 USD Main Range of product

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

Switches with manual reset

Switches with manual reset Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Voltage limiting device HVL

Voltage limiting device HVL Datasheet Voltage limiting device HVL 60-0.3 1 2 3 3 Equivalent circuit of voltage limiting device Type HVL 60-0.3 1 MO-surge arrester 2 Trigger electronics 3 Thyristor Product Description The HVL 60-0.3

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

The vacuum circuit breaker for commercial buildings, industrial plants and utilities The vacuum circuit breaker for commercial buildings, industrial plants and utilities EasyPact EXE The easy choice for more value 2 EasyPact EXE EasyPact EXE, a medium voltage vacuum circuit breaker optimizing

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information