Pre-Delivery Guide.

Size: px
Start display at page:

Download "Pre-Delivery Guide."

Transcription

1 Thank you for purchasing a Clearwater spa. Clearwater manufacturers the best built and most energy efficient spas in the industry. You have now entered an elite group of spa owners. pre-delivery guide

2 IMPORTANT INFORMATION Please take a moment to read through the information provided on these pages. We want you to receive your purchase in excellent condition so you can begin enjoying it. The information also includes important specifications about how to prepare the site for the delivery. This book specifically covers site preparation, delivery access, and electrical requirements. Remember to read the Owner s Manual, located in the equipment area of the spa. Some of the instructions here are also located in the Owner s Manual. On the data plate is the spa model and serial number, which is important for warranty claims. Clearwater Spas reserves the right to change or modify the spas or any of the features without notification or any obligation. Please make a record of the following information. It will be valuable if service is required. Date Purchased: Date Installed: Dealer: Address: Phone: 2

3 In most cities, permits are required for the installation of electrical circuits or the construction of a deck or gazebo. In addition, some communities have ordinances concerning hot tubs, usually directed toward their safety when no one is home. Your Clearwater Spa cover is equipped with safety locks to prevent unsupervised child access. For any further questions or clarifications, your local building department is a good source. Your Clearwater Spas dealer will be able to answer all of your questions. Clearwater Spas Woodinville/Snohomish Rd. Woodinville, WA Phone: Fax:

4 DELIVERY ACCESS MEASURE BEFORE YOU PURCHASE On the chart below, find your spa and relevant dimensions. These dimensions are of the spa laying on its side. Next, contact your spa dealer for the dimensions of the cart used to deliver your spa. Use the height of the cart and the H measurement for the vertical dimension. Use the width of the cart or W, whichever is greater, to determine the maximum clearances of the width. Dimensions Jets Seats Weights - Empty Filter Area Resort Series Inches Centimeters # # Lbs Kilograms Orlando 92.5" x 92.5" x 39.5" 235 x 235 x cm sf 1100 lbs. 499 Monaco 92.5" x 92.5" x 39.5" 235 x 235 x cm sf 1100 lbs. 499 Cabo 84" x 84" x 34" 213 x 213 x 86 cm sf 800 lbs. 363 Rio 84" x 75" x 34" 213 x191 x sf 700 lbs. 318 Dimensions Jets Seats Weights - Empty Filter Area Beachcraft Series Inches Centimeters # # Lbs Kilograms Pearl Island 92.5" x 92.5" x 39.5" 235 x 235 x cm sf 900 lbs. 408 Tradition 92.5" x 92.5" x 39.5" 235 x 235 x cm sf 900 lbs. 408 St. Andrew 84" x 84" x 34" 213 x 213 x 86 cm sf 700 lbs. 318 Myrtle Beach 84" x 84" x 34" 213 x 213 x 86 cm sf 700 lbs. 318 Dimensions Jets Seats Weights - Empty Filter Area Northwest Series Inches Centimeters # # Lbs Kilograms Broadmoor 92.5" x 92.5" x 39.5" 235 x 235 x cm sf 750 lbs. 340 Twin Peaks 92.5" x 84" x 34.5" 235 x x 87.5 cm sf 700 lbs. 318 Concordia 92.5" x 92.5" x 39.5" 235 x 235 x cm sf 750 lbs. 340 Liberty Lake 84" x 84" x 34" 213 x 213 x 86 cm sf 600 lbs. 272 Fairview 84" x 84" x 34" 213 x 213 x 86 cm sf 600 lbs. 272 Dimensions Jets Seats Weights - Empty Filter Area ES & Lite Series Inches Centimeters # # Lbs Kilograms ES93L 92.5" x 92.5" x 39.5" 235 x 235 x cm sf 750 lbs. 340 ES93L Lite sf ES93NL 92.5" x 92.5" x 39.5" 235 x 235 x cm sf 750 lbs. 340 ES93NL Lite sf ES84L 84" x 84" x 34" 213 x 213 x 86 cm sf 600 lbs. 272 ES84L Lite sf ES84NL 84" x 84" x 34" 213 x 213 x 86 cm sf 600 lbs. 272 ES84NL Lite sf ES76L 76" x 76" x 34" 193 x 193 x 86 cm sf 420 lbs. 191 ES76L Lite sf ES76NL 76" x 76" x 34" 193 x 193 x 86 cm sf 420 lbs. 191 ES76NL Lite sf ES76R 76" x 53" x 34" 193 x 135 x sf 360 lbs. 163 ES76R Lite sf ES76CC 76"x76"x40"(c) x 34" 193 x 193 x x sf 410 lbs

5 Note: If there are stairs or other obstacles, the spa will have to travel over to get to the site, additional clearances may be required. Use the supplied measurements to help you determine the best location for your new spa. If you have any problems, contact your dealer for assistance. CAUTION: Clearwater Spas suggests an engineer or contractor be consulted before the spa is placed on an elevated deck. *NOTE: The Weight - Empty and Weight - w/water of the spa includes the weight of the occupants (assuming an average occupant weight of 175 lbs). Weights - w/water Water Capacity Electrical Reqmts. Pumps - U.S. / Can. Pumps - Europe Lbs Kilograms Gallons Liters U.S./Can Euro Pumps Circulation Pumps Circulation 5604 lbs v 220 v hp 1 circ hp 1 circ lbs v 220 v hp 1 circ hp 1 circ lbs v 220 v hp 1 circ hp 1 circ lbs v 220 v hp 1 circ hp 1 circ. Weights - w/water Water Capacity Electrical Reqmts. Pumps - U.S. / Can. Pumps - Europe Lbs Kilograms Gallons Liters U.S./Can Euro Pumps Circulation Pumps Circulation 4486 lbs v 220 v hp 1 circ hp 1 circ lbs v 220 v hp 1 circ hp 1 circ lbs v 220 v hp 1 circ hp 1 circ lbs v 220 v hp 1 circ hp 1 circ. Weights - w/water Water Capacity Electrical Reqmts. Pumps - U.S. / Can. Pumps - Europe Lbs Kilograms Gallons Liters U.S./Can Euro Pumps Circulation Pumps Circulation 4336 lbs v 220 v hp 1 circ hp 1 circ lbs v 220 v hp 1 circ hp 1 circ lbs v 220 v hp 1 circ hp 1 circ lbs v 220 v hp 1 circ hp 1 circ lbs v 220 v hp 1 circ hp 1 circ. Weights - w/water Water Capacity Electrical Reqmts. Pumps - U.S. / Can. Pumps - Europe Lbs Kilograms Gallons Liters U.S./Can Euro Pumps Circulation Pumps Circulation 4336 lbs v 220 v hp 1 circ hp 1 circ. 240 v 220 v hp hp 4503 lbs v 220 v hp 1 circ hp 1 circ. 240 v 220 v hp hp 3269 lbs v 220 v hp 1 circ hp 1 circ. 240 v 220 v hp hp 3436 lbs v 220 v hp 1 circ hp 1 circ. 240 v 220 v hp hp 2588 lbs v 220 v hp 1 circ hp 1 circ. 240 v 220 v hp hp 2922 lbs v 220 v hp 1 circ hp 1 circ. 240 v 220 v hp hp 1861 lbs v 220 v hp 1 circ hp 1 circ. 240/120 v 220 v hp hp 2245 lbs v 220 v hp 1 circ hp 1 circ. 5

6 STEPS FOR A SUCCESSFUL INSTALLATION: 1. PREPARING FOR YOUR SPA Prior to receiving your new spa, you will need to prepare an area to install the spa. You will need to arrange to have your spa placed in your desired location and for the connection of the electrical circuits. In most cities, permits are required for the installation of electrical circuits. Review the path that your spa will take through your property along with the size of the spa to ensure you have enough clearance. If there are stairs or other obstacles, the spa will have to travel over to get to the site, additional clearances may be required. We have listed some key points to installing your spa that will help eliminate some of the unforeseeable situations that could occur. Avoid installing too close to a building or structure. Leave enough room around all sides to allow access to service panels. Install on a load bearing, level platform. Do not install less than 5 feet from ground conductors. Use non-conductive conduit for all wiring. If installing below a deck surface, leave enough room to access and remove service panels. We recommend a level 4 thick concrete pad if you are installing on land (versus deck or platform). The dimensions of the pad should be at least the outside dimension of the spa. You should also accommodate for steps or other items around the spa. Allow a few days for curing the cement when calculating your scheduled delivery date. Balconies and upper decks are not recommended for spa installations, but if you choose to do so, keep in mind that a large filled spa with 6 people can weigh as much as three tons. Balconies and decks must be constructed to current state and local building codes and must support at least 100 pounds per square foot. If you are building a deck around the spa, be sure that the deck does not cover any of the service panels to the spa. If you are building stairs for getting up to the spa, it is recommended that they be installed in such a way that they can be moved out of the way if entrance to the service panels is required. The most obvious thing to remember is to plan your installation in a location where it will be easy to move from the delivery truck to the location site. Spas are typically transported on a mover s dolly lying on their side. Check for adequate gate clearance and remove any fence panels if necessary to allow access to the installation site. 6

7 2. SITE SELECTION AND PREPARATION The location of your hot tub is entirely up to you. Carefully read these instructions for various ideas of locations that your new hot tub may be placed. By the time you have made your spa purchase, you probably have a spot already picked out. Prior to the spa delivery, please verify the following: Always place the spa on a compacted and level surface. The best surface is a level concrete pad. A spa, full of water, can weigh a great deal. Please ensure the spot can support the weight. Make sure to level your spa before filling it. Locate the equipment panel. The control box, drain valve, and optional ozone generator are usually located all in the same area. Be sure that the connections are tightened during filling. Water inside the system pack will cause the pack to fail and the breaker to trip. The panels, on all four sides, are removable. Be sure to have access on all four sides. Be sure to have easy access to the circuit breaker in the sub panel (220 volt models). Never let water into the sub panel (220 volt models), or into the electrical outlet that your spa is plugged in to. Your 220 volt spa s control box is rain tight when installed correctly with the door closed. 3. INSTALLATION - PLACING YOUR SPA OUTDOOR AND PATIO INSTALLATION To position the spa correctly in your backyard is very important. The warranty on a spa is voided if the site is not level. If you install your hot tub outdoors, a concrete pad is the best method for a stable and level surface. The concrete pad should be four inches thick. Your spa may be installed on a deck, providing the load rating can handle a full spa with people in it. DECK INSTALLATION When placing the spa on a deck, please ensure the maximum load capacity of the deck. Consult a qualified deck builder or structural engineer before you place the hot tub on an elevated deck or indoors. To determine the weight of your hot tub, please refer to the specifications on the website. This weight must not exceed the structural weight of the deck. 7

8 INDOOR INSTALLATION When installing a spa indoors, there are some special considerations. The combination of heat and moisture will accumulate on the floor and surrounding the spa. The flooring material needs to provide a grip when wet. The location also needs proper drainage to prevent water build-up around the spa. When building a room for your spa, it is best to have a floor drain installed. The humidity of a room with a spa can become a problem if there is not enough proper ventilation. Otherwise, problems such as dry rot, mildew or other problems may occur. GROUND PREPARATION Your spa has been engineered to rest on a variety of surfaces. The insulated spa floor base gives you the ability to find the perfect place. A concrete slab is the best for long term. There are other options available as long as the surface is level prior to delivery. The alternatives are 5/8 minus crushed packed rock, or a deck that is rated for the load. Brick pavers Cement Stone, slate, granite Decking: wood, synthetic When placing a spa on crushed rock, the easiest way to maintain its form is to build a frame and fill it with the crushed packed rock. Remember, if the spa is placed on grass or dirt, debris will get inside the spa as the users enter and exit. It is incredibly important to the operation and the draining of the tub for the tub to be level once it is installed. Failure to have the spa level prior to adding water can affect the warranty. Packed/crushed gravel: 5/8 minus Marble, travertine Decorative cement, stained Decorative cement & bricks 4. ELECTRICAL HOOK-UP REQUIREMENTS - 220V REMOVING SPA PANELS: DURATECH 1. Unscrew and remove trim pieces Unscrew and remove cabinet panel. This allows access to spa components.

9 REMOVING RIM 1. Remove the plastic tap-cap decorative screw head covers from screws on access spa panel. 2. Unscrew the screws from the access spa panel. 3. Remove the spa panel for access to spa components. Reverse these steps to attach the spa panel. ELECTRICAL CONNECTIONS BY LICENSED PERSONNEL To ensure you will have an opportunity to use your hot tub soon after delivery, it is very important that the required electrical service has been installed beforehand. IMPORTANT: ELECTRICAL CONNECTIONS MUST BE MADE BY QUALIFIED, LICENSED PERSONNEL. PLEASE CONTACT A LICENSED RESIDENTIAL ELECTRICIAN FOR THESE SERVICES. All models require a 50 amp single phase, 220 volt circuit breaker in the main electrical service panel. NOTE: WE REQUIRE THAT A SUB PANEL BE USED TO SUPPLY POWER AND PROTECT THE SPA. All 220 volt Clearwater spas must be wired in accordance with applicable local electrical codes, and all electrical work must be done by a licensed electrician. A licensed electrician should install a four-wire electrical service (two line voltages, one neutral, one ground) from the main electrical service panel to the sub-panel, and from the subpanel to the spa per the appropriate wiring diagram as illustrated on the next page (Figure 1-1). The grounding conductor must be at least #6 AWG. Your electrician should mount the sub-panel in the vicinity of the spa but it should not be closer than five (5) feet from the spa s water edge (NEC to 41-A-3). WARNING: Removing or bypassing the GFCI breakers in the sub panel at any time will result in an unsafe spa and will void the warranty. WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge feed wire than stated. We recommend that a maximum voltage drop of 3% be used when calculating the larger wire size. Refer to the Wiring Diagrams (figure 1-1) for the electrical requirements of the 220 volt models. Do not turn on power to the spa when the tub is not filled with water. The closer you locate the spa to the main service panel, the less money you will have to spend on wire. Wire can become expensive if you run long lengths. Always shut off power at the source when working with any electrical power!! Failure to do this could result in serious injury or even death! 9

10 ELECTRICAL REQUIREMENTS - 220V (CONT.) IMPORTANT: Electrical connections must be made by qualified, licensed personnel. Please contact a licensed residential electrician for these services. Figure volt wiring configuration from the house to the spa 10

11 ENERGY EFFICIENCY GREEN TECHNOLOGY PROVIDING A GREENER SPA. Clearwater Spas is strongly committed to protecting the health of our environment and manufacturing energy efficient hot tubs that help to conserve our natural resources. We strive to provide clean air, clean water and recycling solutions in our manufacturing process and the components that go into our spas. E-SMART TECHNOLOGY Your spa is made with e-smart or technology built into every hot tub to provide a complete energy efficient system. From the initial engineering design stage through our manufacturing, product usage, we have set a high standard to keep our hot tubs environmentally sound. This symbol signifies the highest energy efficiencies, the smartest engineering detail standards, global environmentally green components and e-cycling sound programs. Energy Efficient ENERGY EFFICIENT Clearwater Spas RTB (reflective thermal barrier) rigid insulation is 12% more energy efficient than spray foam insulation. Our insulation panels reflect and recycle heat from within the cabinet keeping it warm and dry. CEC Certified CALIFORNIA ENERGY COMMISSION (CEC) CERTIFIED All of Clearwater Spas are certified to California s Energy Commission (CEC) the most stringent energy efficiency standards in the United States. We not only meet these standards we exceed them. Manufacturing HEALTHY FACTORY PROCESS We are focused on providing healthy and safe solutions in our factory for our employees and our environment. This includes processes for good air quality, and energy efficient components. Clean Air CLEAN AIR FACTORY Our Eco-Spray process for strengthening every spa shell has 0% styrene, no odor and emits no VOC s (volatile organic compounds) for a cleaner air environment. Clean Water CLEAN WATER SOLUTIONS We provide cutting edge clean water sanitizing solutions to help provide natural alternatives and help reduce the need for chemicals. UV-C light, ozone and re-usable filters provide natural clean water solutions. 11

12 Resort Series Orlando 92.5" (235 cm) Ground Contact 86" (218.4 cm) 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #2 Pump #4 Circ. Pump Pump #3 Pump #1 31" (78.7 cm) 12

13 Monaco 92.5" (235 cm) Ground Contact 86" (218.4 cm) Resort Series 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16" (41 cm) 16" (41 cm) Pump #3 Pump #4 Circ. Pump Pump #1 Pump #2 31" (78.7 cm) 13

14 Resort Series Cabo 84" (213.4 cm) Ground Contact 76" (193 cm) 84" (213.4 cm) Ground Contact 76" (193 cm) 16" (41cm) 16" (41cm) Pump #3 Pump #4 Pump #1 Pump #2 Circ Pump 28" (68.6 cm) 14

15 Rio 75" (190.5 cm) Ground Contact 71" (180.3 cm) Resort Series 84" (213.4 cm) Ground Contact 78" (198 cm) 16" (41 cm) 16" (41 cm) Pump #1 Pump #2 Circ. Pump 28" (71 cm) 15

16 Beachcraft Series Pearl Island 92.5" (235 cm) Ground Contact 86" (218.4 cm) Circ. Pump 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #2 Pump #1 Pump #3 31" (78.7 cm) Electrical Knockout 16

17 Tradition 92.5" (235 cm) Ground Contact 86" (218.4 cm) Beachcraft Series 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #2 Pump #3 Circ. Pump Pump #1 31" (78.7 cm) Electrical Knockout 17

18 Beachcraft Series St. Andrew 84" (235 cm) Ground Contact 78" (198.1 cm) Circ. Pump 84" (235 cm) Ground Contact 78" (198.1 cm) 16 (40.6 cm) Pump #3 16 (40.6 cm) Pump #2 27" (68.6 cm) 18

19 Myrtle Beach Beachcraft Series 84" (235 cm) Ground Contact 78" (198.1 cm) 84" (235 cm) Ground Contact 78" (198.1 cm) 16" (41 cm) 16" (41 cm) Pump #2 Pump #3 Circ. Pump Pump #1 28" (71cm) 19

20 Northwest Series Broadmoor 92.5" (235 cm) Ground Contact 86" (218.4 cm) 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #3 Pump #1 Pump #2 Circ. Pump 31" (78.7 cm) Electrical Knockout 20

21 Concordia Northwest Series 92.5" (235 cm) Ground Contact 86" (218.4 cm) 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #3 Pump #1 Pump #2 Circ. Pump 31" (78.7 cm) Electrical Knockout 21

22 Northwest Series Twin Peaks 84" (213 cm) Ground Contact 86" (218.4 cm) 92.5" (235 cm) Ground Contact 86" (218.4 cm) 16 (40.6 cm) 16 (40.6 cm) Pump #3 Pump #1 Pump #2 Circ. Pump 31" (78.7 cm) Electrical Knockout 22

23 Liberty Lake Northwest Series 84" (235 cm) Ground Contact 78" (198.1 cm) 84" (235 cm) Ground Contact 78" (198.1 cm) 16 (40.6 cm) Pump #3 Pump #1 Pump #2 Circ. Pump 16 (40.6 cm) 27" (68.6 cm) 23

24 Northwest Series Fairview 84" (235 cm) Ground Contact 78" (198.1 cm) 84" (235 cm) Ground Contact 78" (198.1 cm) 16 (40.6 cm) Pump #1 Pump #2 Circ. Pump 16 (40.6 cm) 27" (68.6 cm) 24

25 ES Series ES93L 92.5" (235 cm) Ground Contact 84" (213.4 cm) 92.5" (235 cm) Ground Contact 84" (213.4 cm) 16" (41 cm) 16" (41 cm) Pump #1 Circ. Pump Pump #2 31" (78.7 cm) 25

26 ES Series ES " (235 cm) Ground Contact 84" (213.4 cm) 92.5" (235 cm) Ground Contact 84" (213.4 cm) 16 (40.6 cm) Pump #2 Pump #1 16 (40.6 cm) Circ. Pump 31" (78.7 cm) Electrical Knockout 26

27 ES Series ES84L 84" (213.4 cm) Ground Contact 76" (193 cm) 84" (213.4 cm) Ground Contact 76" (193 cm) 16" (41 cm) 16" (41 cm) Pump #1 Pump #2 Circ. Pump 28" (71 cm) 27

28 ES Series ES84 84" (213.4 cm) Ground Contact 76" (193 cm) 84" (213.4 cm) Ground Contact 76" (193 cm) 16 (40.6 cm) Pump #2 Pump #1 16 (40.6 cm) Circ. Pump 28" (68.6 cm) Electrical Knockout 28

29 ES Series ES76L 76" (193 cm) Ground Contact 72" (183 cm) 76" (193 cm) Ground Contact 72" (183 cm) 16" (41 cm) 16" (41 cm) Pump #1 Pump #2 Circ. Pump 28" (71 cm) Electrical Knockout 29

30 ES Series ES76 76" (193 cm) Ground Contact 72" (183 cm) 76" (193 cm) Ground Contact 72" (183 cm) 16" (41 cm) 16" (41 cm) Pump #2 Pump #1 Circ. Pump 27" (69 cm) 30

31 ES Series ES76CC 76" (193 cm) Ground Contact 69" (175 cm) 77" (193 cm) Ground Contact 69" (175 cm) 16" (41 cm) 16" (41 cm) Pump #1 Pump #2 Circ. Pump Approx. 36" (91 cm) 23" (58.4 cm) Electrical Knockout 31

32 ES Series ES76R 53" (135 cm) Ground Contact 46" (117 cm) Pump #2 Circ. Pump 76" (193 cm) Ground Contact 69" (175 cm) Pump #1 24" (61 cm) 16" (40.6 cm) Electrical Knockout 32

33 ES93L-Lite ES Lite Series 92.5" (235 cm) Ground Contact 84" (213.4 cm) Pump #1 (Euro Pump #1) 92.5" (235 cm) Ground Contact 84" (213.4 cm) Circ. Pump Subwoofer 8" (20 cm) (Euro Blower) Pump #2 (Euro Pump #2) 31" (78.7 cm) Salt System Control Salt System Electrode Topside Control Equipment Access 33

34 ES Lite Series ES93-Lite 92.5" (235 cm) Ground Contact 84" (213.4 cm) Pump #1 (Euro Pump #1) Pump #2 (Euro Pump #2) 92.5" (235 cm) Ground Contact 84" (213.4 cm) Subwoofer (Euro Blower) Circ. Pump 8" (20 cm) 31" (78.7 cm) Salt System Control Salt System Electrode Topside Control Equipment Access 34

35 ES84L-Lite 84" (213.4 cm) Ground Contact 76" (193 cm) ES Lite Series Pump #1 (Euro Pump #1) Pump #2 (Euro Blower) 84" (213.4 cm) Ground Contact 76" (193 cm) Circ. Pump (Euro Pump #2) 8" (20 cm) Subwoofer 27" (68.6 cm) Equipment Access Salt System Electrode Salt System Control Topside Control 35

36 ES Lite Series ES84-Lite 84" (213.4 cm) Ground Contact 76" (193 cm) Pump #1 (Euro Pump #1) Pump #2 (Euro Blower) 84" (213.4 cm) Ground Contact 76" (193 cm) (Euro Pump #2) 8" (20 cm) Circ. Pump Subwoofer 27" (68.6 cm) Equipment Access Salt System Control Topside Control Salt System Electrode 36

37 ES76L Lite ES Lite Series 76" (193 cm) Ground Contact 72" (183 cm) 76" (193 cm) Ground Contact 72" (183 cm) 16" (41 cm) 16" (41 cm) Circ. Pump Pump #1 25" (64 cm) Electrical Knockout 37

38 ES Lite Series ES76 Lite 76" (193 cm) Ground Contact 72" (183 cm) 76" (193 cm) Ground Contact 72" (183 cm) 16" (41 cm) 16" (41 cm) Circ. Pump Pump #1 25" (64 cm) Electrical Knockout 38

39 ES76R Lite 76" (193 cm) Ground Contact 72" (183 cm) ES Lite Series 76" (193 cm) Ground Contact 72" (183 cm) Circ. Pump Opt. Pump #1 8" (20 cm) 25" (64 cm) Salt System Control Salt System Electrode Topside Control Equipment Access 39

40 NOTES FOR YOUR HOT TUB CONTRACTOR SUGGESTIONS Electrician Name: Telephone: Name: Telephone: Masonry Name: Telephone: Name: Telephone: General Name: Telephone: Name: Telephone: Services available from your Clearwater Spas dealer SERVICE CHECKLIST AND ANY COSTS Pre-Delivery site inspection Deliver spa to installation site Unwrap spa and haul away packaging material Set up and level spa General spa operation and maintenance orientation Water quality and maintenance operation Adjust the water s Total Alkalinity, Calcium Hardness and ph Sanitize the water Inspect the spa cover, place on spa Review winterizing instructions Review Owner s Manual Follow-up call In-store water analysis Total Costs 40

41 NOTES FOR YOUR HOT TUB Additional products that may be available from your Clearwater Spas Dealer Salt Sanitation System Clean Light UV-C Sanitation System CD Ozone Generator Nature 2 Sticks Nature 2 test strips Stain and Scale Remover Filter Cleaner Ph-Alkalinity Up Ph-Alkalinity Down Concentrated Chlorinating Granules Defoamer Calcium Hardness Increaser 4-way test strips Coverlift Cover Rock-It Vinyl covers Spa vacuums Spa steps Stain kits Replacement filter cartridges Pillows 41

42 NOTES: 42

43 NOTES: 43

44 18800 Woodinville/Snohomish Rd. P.O. Box 2140 Woodinville, WA pre-delivery guide

Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners. DATE INSTALLED: DEALER:

Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners. DATE INSTALLED: DEALER: HIGHLIFE COLLECTION Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners. Pre-Delivery Instructions Please take the time to read

More information

Spa Location and Preparation 4-5. Wood or Synthetic Deck Installation 6. Delivery Access Backyard Delivery 7. How To Measure For Backyard Delivery 8

Spa Location and Preparation 4-5. Wood or Synthetic Deck Installation 6. Delivery Access Backyard Delivery 7. How To Measure For Backyard Delivery 8 PRE- DELIVERY GUIDE Pre-Delivery Guide Congratulations. Your new Spa is designed to give you years of pleasure. Please take the time to read this booklet carefully, as it will provide you with the information

More information

Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners.

Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners. Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners. Pre-Delivery Instructions Please take the time to read this booklet carefully,

More information

Pre-Delivery Instructions

Pre-Delivery Instructions HIGHLIFE COLLECTION Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of HOT SPRING spa owners. Pre-Delivery Instructions Please take the time to read

More information

Pre-Delivery Guide. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

Pre-Delivery Guide. How to make delivery and installation of your new hot tub fast, easy and trouble-free. Pre-Delivery Guide How to make delivery and installation of your new hot tub fast, easy and trouble-free. Important Service Information Please make a record of the following information. It will be valuable

More information

PRE-DELIVERY GUIDE How to make the delivery and installation of your new hot tub fast, easy, and trouble-free

PRE-DELIVERY GUIDE How to make the delivery and installation of your new hot tub fast, easy, and trouble-free PRE-DELIVERY GUIDE 2008 How to make the delivery and installation of your new hot tub fast, easy, and trouble-free Important Pre-Delivery Information Please read this booklet before your scheduled delivery

More information

PRE-DELIVERY GUIDE 2011

PRE-DELIVERY GUIDE 2011 PRE-DELIVERY GUIDE 2011 How to make the delivery and installation of your new hot tub fast, easy, and trouble-free WATER THAT MOVES YOU Important Pre-Delivery Information Please read this booklet before

More information

LTR , Rev. P 1/14/15

LTR , Rev. P 1/14/15 1/14/15 Locating Your Spa...1 Pre-Delivery Checklist....1 Planning the Best Location...1 Getting the Spa Into Your Yard... Preparing a Good Foundation... Clearance for Service Access...4 Electrical Service

More information

PRE-DELIVERY GUIDE How to make the delivery and installation of your new hot tub fast, easy, and trouble-free

PRE-DELIVERY GUIDE How to make the delivery and installation of your new hot tub fast, easy, and trouble-free PRE-DELIVERY GUIDE 2015 How to make the delivery and installation of your new hot tub fast, easy, and trouble-free Important Pre-Delivery Information Please read this booklet before your scheduled delivery

More information

saratoga spas ADVANCE DELIVERY GUIDE Key steps to making the delivery and installation of your new spa smooth and hassle-free

saratoga spas ADVANCE DELIVERY GUIDE Key steps to making the delivery and installation of your new spa smooth and hassle-free saratoga spas ADVANCE DELIVERY GUIDE» Key steps to making the delivery and installation of your new spa smooth and hassle-free Essential Product Information Please make a note of the following information,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

Installation Manual. D3600- Series Duplex Grinder Systems. Contents Installation Manual 7353000E D3600- Series Duplex Grinder Systems Features: 36 Diameter Fiberglass Tank Available in 48, 60, 72, 84, and 96 heights LSG Single or LSGX 2 Stage 2HP Grinder Pumps Factory

More information

Owner's/Installation Manual

Owner's/Installation Manual Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH

More information

PRE-DELIVERY. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

PRE-DELIVERY. How to make delivery and installation of your new hot tub fast, easy and trouble-free. PRE-DELIVERY How to make delivery and installation of your new hot tub fast, easy and trouble-free. Important Pre-Delivery Information Please read this booklet before your scheduled delivery day. Record

More information

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Installation Manual. Q Series Quadplex Grinder Systems. Contents Installation Manual 7759000A Q4800 - Series Quadplex Grinder Systems Features: 48 Diameter Fiberglass Tank Available in 84, 96, and 120 heights LSG Single or LSGX 2 Stage 2 HP Grinder Pumps Factory Installed

More information

poollux Power plx-pw60 & plx-pw100

poollux Power plx-pw60 & plx-pw100 poollux Power plx-pw60 & plx-pw100 ETL LISTED Conforms to UL STD 379; Certifi.ed.to.CSA.STD.C22.2.#218.1 5005508 Installation Instructions Read all instructions before attempting to perform installation

More information

Installation Instructions

Installation Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Installing and servicing air conditioning equipment

More information

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 AQUALUMIN III NICHELESS POOL LIGHT INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Section Contents 1. Installing a mounting bracket and light

More information

IntelliTouch Pool and Spa Control System Load Center and Power Center

IntelliTouch Pool and Spa Control System Load Center and Power Center pool/spa control system IntelliTouch Pool and Spa Control System Load Center and Power Center IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation Guide 2008

More information

HERCULES II DC OWNER S MANUAL HERCULES II DC RESIDENTIAL & COMMERCIAL

HERCULES II DC OWNER S MANUAL HERCULES II DC RESIDENTIAL & COMMERCIAL HERCULES II DC OWNER S MANUAL Please read this Owner s Manual carefully before using your Hercules II Vertical Platform Lift to ensure safe and correct operation. Keep this manual in a safe place for future

More information

MODEL D-SBG Single Arm Barrier Gate Operator

MODEL D-SBG Single Arm Barrier Gate Operator INSTALLATION AND OWNER S MANUAL MODEL D-SBG Single Arm Barrier Gate Operator UL 325 and UL 991 Listed WITH NITRO BOARD (SEE SUPPLEMENTAL MANUAL) Serial #: Date Installed: Your Dealer: READ THIS MANUAL

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products 2 to 5 Tons Accessory Electric Heaters Cancels: IIK 564A-24-2 IIK 564A-24- -02 Installation Instructions Electric Heaters 5 20 kw NOTE: Read the entire instruction manual before

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products to 5 Tons Accessory Electric Heaters Cancels: IIK 564A--1 IIK 564A-- 11-01 Installation Instructions Electric Heaters 5 0 kw NOTE: Read the entire instruction manual before starting

More information

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light installation Manual English Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified

More information

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch. 3560 NE ROZENE WAY BREMERTON, WASHINGTON 98311 (530) 316-1049 Generator Transfer Switch Model; HTS15-MAN & HTS15-MAN-2 Tools Needed For Installation Power drill Wire stripper and cutter (10 to 14 gauge)

More information

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -

More information

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016 UTILITY/CATV SERVICES CHAPTER 9 900. GENERAL A. Alliant Energy receives many requests for electric service from other utilities; telephone, telecommunications companies, cable television, the Department

More information

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems INSTALLATION GUIDE For Carrier/Bryant Residential Power Systems For 100 Amp Automatic Transfer Switch/Load Center Model: KGATX0116100 16 circuit installed with 16kW generators. This Automatic Transfer

More information

Transformer Installation, Operation, and Maintenance Manual

Transformer Installation, Operation, and Maintenance Manual Transformer Installation, Operation, and Maintenance Manual CONTENTS INTRODUCTION......................................... 2 INSPECTION UPON RECEIVING... 2 STORAGE...............................................

More information

Model 8144NC Fresh Air Ventilator

Model 8144NC Fresh Air Ventilator Model 8144NC Fresh Air Ventilator Installation and Operating Instructions MOUNTING BRACKETS WIRE ENTRY LOCATION INTEGRAL PRESSURE PORTS (PORT ON INLET SIDE NOT SHOWN) OVAL OUTLET COLLAR FOR 6" DIAMETER

More information

Users Manual Certified Series Direct Drive Pump 1-7 LPM

Users Manual Certified Series Direct Drive Pump 1-7 LPM Users Manual Certified Series Direct Drive Pump 1-7 LPM Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232 www.fogco.com

More information

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS Body Specifications 236 Protecting your vehicle from corrosion 237 Washing and waxing 238 Cleaning the interior 239 235 SPECIFICATIONS DIMENSIONS AND WEIGHT

More information

2460 / 2472 / Series Simplex Grinder Systems

2460 / 2472 / Series Simplex Grinder Systems Installation Manual 5651000I 2460 / 2472 / 2484 - Series Simplex Grinder Systems Features: LSG or LSGX Series 2HP Grinder Pump 24 dia. Basin available in 60, 72, or 84 depths Guide Rail System Preassembled

More information

8300 Series Installation Guidelines

8300 Series Installation Guidelines 1-800-443-4859 8300 Series Installation Guidelines WARNING: RISK OF ELECTRICAL SHOCK OR BURNS. THIS CONVERTER ASSEMBLY SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN OR CERTIFIED RV TECHNICIAN. IMPROPER

More information

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS PowerMaster TABLE OF CONTENTS MODEL MBG MEDIUM DUTY BARRIER GATE OPERATOR Important Safety Information...... 3 System Designer Safety Instructions.......4 Installer Safety Instructions....... 5 Installation

More information

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding

More information

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt Owners Manual Fiberstars 44259 Nobel Drive Fremont, CA 94538 www.fiberstars.com 79-15014-00 REV B - 1 - CAREFULLY READ AND

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be

More information

UPPCO SERVICE MANUAL

UPPCO SERVICE MANUAL Revised 01/2015 Section 6 ELECTRIC SERVICE - GENERAL Page 1 of 10 Section 6 Electric Service - General 6-1 Number of Services and Voltages / Meter... 2 6-2 Energy Conversion Factors... 7 6-3 Lightning

More information

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body

SECTION 6 5 SERVICE PROCEDURES AND SPECIFICATIONS. Body SERVICE PROCEDURES AND SPECIFICATIONS Body SECTION 6 5 Specifications........................................... 208 Protecting your vehicle from corrosion...................... 209 Washing and waxing.....................................

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following models: 9000 Series 6000 Series To ensure that the system is installed properly, provide your electrician with these instructions.

More information

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

4 ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause 4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. CAUTION Fill pump with water before starting or pump will be damaged. The motor on

More information

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System Installation Instructions DuraMAC TM Light Commercial & Irrigation Water Pressure Booster System The DuraMAC TM Water Pressure Booster System is the first booster pump of its kind to be designed for virtually

More information

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5 PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument

More information

ALL PURPOSE CNC/HEAVY DUTY

ALL PURPOSE CNC/HEAVY DUTY ALL PURPOSE CNC/HEAVY DUTY Rotary Phase Converters 240 & 480 VOLT SERIES Rotary Phase Con verter Operation & Installation Manual MTPC-RB-208.240-1P-10HP-3P DANGER: HIGH VOLTAGE Electric shock could result

More information

! WARNING! WARNING. Dock Boxes Unlimited, Inc. strongly recommends that these products be installed by a qualified electrician.

! WARNING! WARNING. Dock Boxes Unlimited, Inc. strongly recommends that these products be installed by a qualified electrician. Coming together is a beginning. Keeping together is progress. Working together is success. Installation Instructions for the Hatteras Light Power Pedestal (#70-8631)! DANGER! WARNING! WARNING Hazardous

More information

Contents. Delivering your Canadian Spa. Pre-Delivery Guide.

Contents. Delivering your Canadian Spa. Pre-Delivery Guide. Contents CHOOSE YOUR LOCATION PLANNING PERMISSION PRE-DELIVERY PREPARATION DELIVERY AND ACCESS Delivering your Canadian Spa POSITIONING OF YOUR SPA SETTING UP YOUR HOT TUB/SPA INSTALLATION AND ELECTRICAL

More information

Refer to the franchised waste hauler for further assistance with capacity needs and container sizes:

Refer to the franchised waste hauler for further assistance with capacity needs and container sizes: COMMERCIAL ESTABLISHMENT ENCLOSURE GUIDELINES Alameda County s Mandatory Recycling Ordinance #2012-01 requires businesses to have sufficient recycling collection services to handle the amount of recyclable

More information

Technical Manual. DLM Module. This manual should remain with the unit.

Technical Manual. DLM Module. This manual should remain with the unit. Technical Manual DLM Module This manual should remain with the unit. Safety Rules SAVE THESE INSTRUCTIONS! Read the following information carefully before attempting to install, operate or service this

More information

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS The DuraMAC TM Water Pressure Booster System is the first booster pump of its kind to be designed for virtually

More information

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m) Model T0828 Primary pump 1/HP 200 GPH Head of 20 (6 m) SUBMERSIBLE SUMP DUPLEX SYSTEM Professional Séries Discharge: 1 1/2 ABS DWV pipe Electric cable: 9 piggyback type Oil cooled Cast iron construction

More information

CHAPTER V RESIDENTIAL WIRING

CHAPTER V RESIDENTIAL WIRING CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this

More information

SOLID WASTE AND RECYCLING ENCLOSURE STANDARDS

SOLID WASTE AND RECYCLING ENCLOSURE STANDARDS SOLID WASTE AND RECYCLING ENCLOSURE STANDARDS Kitsap County Public Works July 2019 If you have any questions regarding the Standards or have recommendations for improvement, please contact: Sarah Olson

More information

Load & Lock Cremators

Load & Lock Cremators Earth Smart Solutions Load & Lock Cremators Instruction Manual Product/Service Information Installer/Service Tech This manual must be used only by a qualified service technician. Failure to comply with

More information

MODEL D-WBG Wishbone Arm Barrier Gate Operator

MODEL D-WBG Wishbone Arm Barrier Gate Operator INSTALLATION AND OWNER S MANUAL MODEL D-WBG Wishbone Arm Barrier Gate Operator UL 325 and UL 991 Listed WITH NITRO BOARD (SEE SUPPLEMENTAL MANUAL) Serial #: Date Installed: Your Dealer: READ THIS MANUAL

More information

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 4558-153-E75 4558-153-E75 APPLICATION: Multi-fixture Marine fresh water system installation.

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090529 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW Line/Load Reactors are components designed to improve the

More information

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s.   PEGAS E Smart Manual EN 04 WELDING INVERTER PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL PEGAS 160-200 E Smart Manual EN 04 2/12 CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL DATA...

More information

JAZZ J400C (COLOR), J400AS (AUTO SYNC)

JAZZ J400C (COLOR), J400AS (AUTO SYNC) Fiberstars JAZZ J400C (COLOR), J400AS (AUTO SYNC) Owners Manual Fiberstars 44259 Nobel Drive Fremont, CA 94538 www.fiberstars.com Rev.E 08/04/04-1 - P/N 75-15046-PM CAREFULLY READ AND FOLLOW ALL SAFETY

More information

PRE-PLUMBED SEWAGE SYSTEM

PRE-PLUMBED SEWAGE SYSTEM PRE-PLUMBED SEWAGE SYSTEM Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1910-0009 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL 10-04-00 CONTENTS Safety Precautions... 2 Applications... 3 Pre-Installation Checklist...

More information

Owner s Information Manual

Owner s Information Manual 50ES---A and 50VL---C Comfort 13SEERThreePhase2½---5NominalTons (Sizes 30---60) Comfort 14 SEER Single and Three Phase 2---5 Nominal Tons (Sizes 24---60) Single Packaged Air Conditioner System With Puronr

More information

Metering and Service Installation:

Metering and Service Installation: Table of Contents 1. Metering Installation Requirements, General... 1 2. Type of Service... 2 3. Definitions... 2 4. Who Provides Metering Equipment?... 2 5. Establishment of Service... 2 6. Meter Access...

More information

Owner s Manual. Important!

Owner s Manual. Important! Owner s Manual Watkins Manufacturing Corporation congratulates you on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners. Owner s Manual This Owner

More information

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh TECHNICAL SPECIFICATIONS P3R(A,C) Series Single Packaged Air Conditioner, Single Phase P3RA-10 SEER 2 thru 5 Ton Units Cooling: 24,000 to 59,000 Btuh P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800

More information

Air Curtain. Installation, Operating and Maintenance Instructions

Air Curtain. Installation, Operating and Maintenance Instructions Installation, Operating and Maintenance Instructions Save this manual for future reference. Air Curtain Model Numbers: ES026, ES036, ES042, ES048, ES060, ES072 READ THIS OWNER S MANUAL CAREFULLY BEFORE

More information

Florham Park, NJ USA Call (ASCO) for sales or service

Florham Park, NJ USA Call (ASCO) for sales or service Operator s Manual 7000 Series ATS Automatic Transfer Switches D design, 30 through 230 A DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious

More information

SOUTH SEAS SPAS HYDROTHERAPY BENEFITS FEATURES. Deluxe and Standard South Seas Spas are as dynamic in quality as

SOUTH SEAS SPAS HYDROTHERAPY BENEFITS FEATURES. Deluxe and Standard South Seas Spas are as dynamic in quality as SOUTH SEAS SPAS Deluxe and Standard South Seas Spas are as dynamic in quality as age-old form of healing and stress relief is based on three simple of the body, including skeletal, respiratory, circulatory,

More information

Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle A dream home COMFORT Advanced technology and warm, sober lines for a functional day-to-day. The best sensation is not to notice anything. A dream lifestyle Smooth Silent Precise 3 ACCESSIBILITY Enjoy the

More information

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL Photovoltaic (PV) Residential Page 1 of 10 Revision Date: 07/18/2018 INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL INSPECTION CODE: 703 SCOPE: RESIDENTIAL APPLICABLE CODES: 2016 CBC, CRC, CPC,

More information

Patios Porches Pools Walkways

Patios Porches Pools Walkways Patios Porches Pools Walkways Why Choose Oakville Stone 2 Oakville Blue Ice Why choose Oakville Stone: Proven durability in all climates Large inventory to supply any landscape project Precision cut with

More information

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI 15 GALLON AIR COMPRESSOR Model: 7678 DO NOT RETURN TO STORE Please call 800-348-5004 for parts and service CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials

More information

PRE-DELIVERY. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

PRE-DELIVERY. How to make delivery and installation of your new hot tub fast, easy and trouble-free. PRE-DELIVERY How to make delivery and installation of your new hot tub fast, easy and trouble-free. Important Pre-Delivery Information Please read this booklet before your scheduled delivery day. Record

More information

Nanometrics Solar Power System

Nanometrics Solar Power System Nanometrics Solar Power System Installation Guide Nanometrics Inc. Kanata, Ontario Canada 2003 Nanometrics Inc. All Rights Reserved. Installation Guide The information in this document has been carefully

More information

Electric Vehicle Charging Station

Electric Vehicle Charging Station EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;

More information

Installation Instructions for Lighthouse SS Power Pedestal Rev. 3 5/20/14

Installation Instructions for Lighthouse SS Power Pedestal Rev. 3 5/20/14 Installation Instructions for Lighthouse SS Power Pedestal Rev. 3 5/20/14 Hazardous voltage. Can cause severe injury or death. Turn off main power before opening panel. Eaton Electrical Inc. strongly recommends

More information

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE Please read these instructions thoroughly before installing and operating the range. LDE3019ST LDE3017ST LDE3017SB LDE3017SW LDE3015ST LDE3015SB

More information

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752 Rocking Piston Compressors Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752 Thank you for purchasing the Stratus SRC series rocking piston compressor. This instruction manual

More information

Service Requirements

Service Requirements Service Requirements General Contact Idaho Power before beginning work on any new service. All meter installations must meet current electrical code requirements and display the proper electrical permit.

More information

Solar Power Owner s Manual

Solar Power Owner s Manual Solar Power Owner s Manual Domestic Photovoltaic Systems Introduction Congratulations on the purchase of your solar electricity system. Not only are you protecting yourself from current and future price

More information

Model Numbers SAVI-NOTE75, SAVI-NOTE150

Model Numbers SAVI-NOTE75, SAVI-NOTE150 Installation INSTRUCTIONS & OWNERS Manual SAVI NOTE UNDERWATER LED LIGHT Model Numbers SAVI-NOTE75, SAVI-NOTE150 Safety Precautions...2 SAVI Note Install Instructions...3-4 1 READ AND FOLLOW ALL INSTRUCTIONS

More information

Instruction & Owner s Manual

Instruction & Owner s Manual Instruction & Owner s Manual Table of Contents Page Installation - Plumbing of Chamber 3 Installation - Electronic Control Box 3-4 Transformer Connection 115VDC or 230VDC 4-5 Instructions for use with

More information

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

3 FT CORD Models , , , FT CORD W/GFCI Models , , , POWERLINE XP II Swimming Pool Pump (Light Oak color model) With Automatic Timer 3 FT CORD Models 0-1395-226, 0-1396-226, 0-1397-226, 0-1398-226 25 FT CORD W/GFCI Models 0-1395-220, 0-1396-220, 0-1397-220,

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

OBE-3-FT Outdoor Series

OBE-3-FT Outdoor Series OBE-3-FT Outdoor Series Installation Guide WARNING: Serious Personal Injury Securely mount the enclosure to the ground to prevent tipping. Failure to do so could lead to serious injury or death. Wear appropriate

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com INSTALLATION INSTRUCTIONS MODEL 506518SS AND BY-PRODUCTS LIKE Your pump has been

More information

Owner s Manual GLASSLINED PUMP TANK

Owner s Manual GLASSLINED PUMP TANK Owner s Manual GLASSLINED PUMP TANK ANSI/NSF 61 Annex G Thank You for purchasing a pump tank. Properly installed and maintained, it should give you years of trouble free service. If you should decide that

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium Electric Drive Vehicle Infrastructure Training Instructor s Manual National Alternative Fuels Training Consortium Part 4: : Service Panel to Receptacle Overview of Service Panel The role of the service

More information

VPL-SH1 Vertical Platform Lift

VPL-SH1 Vertical Platform Lift VPL-SH1 Vertical Platform Lift SH1-28 SH1-52 SH1-72 SH1-105 www.serenityhcp.com Page 1 of 27 Standard_Vertical_Lift_Rev 7 Table of Contents Site Preparation and Electrical Guidelines..... 3 Specifications...

More information

LIGHTNING PROTECTION UNIT (LPU)

LIGHTNING PROTECTION UNIT (LPU) LIGHTNING PROTECTION UNIT (LPU) Photovoltaic Lightning Protection Device Installation and Operation Manual SPECIALTY CONCEPTS, INC. 8954 Mason Ave. Chatsworth, CA 91311 USA MODELS COVERED: LPU-50, LPU-150,

More information

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS MANUAL TRANSFER SWITCHES FROM 0 Residential Wattage Requirements Appliance Running Watts Add watts for starting Furnace blower, gas or fuel 1/8 hp 300 500 1/8 hp

More information

SmartBoost 50 INSTALLATION INSTRUCTIONS & OWNER S MANUAL LT93 SMTBST50 1. Issue 1 Print 2 AUTOMATIC SHORELINE TRANSFORMER

SmartBoost 50 INSTALLATION INSTRUCTIONS & OWNER S MANUAL LT93 SMTBST50 1. Issue 1 Print 2 AUTOMATIC SHORELINE TRANSFORMER SmartBoost 50 AUTOMATIC SHORELINE TRANSFORMER INSTALLATION INSTRUCTIONS & OWNER S MANUAL 1 Contents INTRODUCING... THE SmartBoost 50............................................................ 3 Manual

More information

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13 GRINDER PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #2701-0005 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and

More information

Installation Instructions for Admiral Power Pedestal (# )

Installation Instructions for Admiral Power Pedestal (# ) Installation Instructions for Admiral Power Pedestal (#70-8643) Hazardous voltage. Can cause severe injury or death. Turn off main power before opening panel. Eaton Electrical Inc. strongly recommends

More information