1 User Manual Inverter/Charger Oasis 6000 Rev 1.0 Oasis 6000 Series MAY 2012 ISSUE 01
2 PAGE 2 MAY 2012 ISSUE 01
3 Oasis 6000 Series User Manual Contents 1. Introduction Warnings and Cautions Contacting MLT Drives Product Support Contact Details Telephone System Configuration Specifications AC Output specifications AC Input specifications DC specifications General technical specifications Climatic conditions System Description Setup and Operation Installing the Oasis Selecting a suitable location Mounting Making the electrical connections Setting up the Oasis Powering up the Oasis Powering down the Oasis Operation of the Oasis The user interface Operational Modes MAY 2012 ISSUE 01 PAGE 3
4 2.2.3 Status indicators Connecting an external AC source Preparation Installing a Generator About Batteries General Battery Bank Location Maintenance Replacing a Battery Battery charger settings Selecting the battery charging current Selecting the battery charging voltage About Solar Panels Introduction Using a Solar System with the Oasis Trouble Shooting Faults Typical Problems Glossary PAGE 4 MAY 2012 ISSUE 01
5 List of Illustrations Figure 1: De-rating the Oasis 6000 output power at high altitude Figure 2: Typical Oasis 6000 System Figure 3: Identifying parts of the Oasis Figure 4: Positioning the mounting holes Figure 5: M8 Rawl bolt Figure 6: Detail of mounting bolt Figure 7: Detail of hanging bar Figure 8: Removing the user interface connectors Figure 9: AC Input/output Connections on the Oasis Figure 10: DC cables Figure 11: Oasis 6000 DC connections Figure 12: Oasis 6000 Front panel Figure 13: Selecting the charging current and voltage MAY 2012 ISSUE 01 PAGE 5
6 1. Introduction 1.1 Warnings and Cautions A safety instruction (message) includes a hazard alert symbol and a signal word, WARNING or CAUTION. Each signal word has the following meaning: HIGH VOLTAGE: This symbol indicates the presence of a high voltage. It calls your attention to items or operations that could be dangerous to yourself or others operating this equipment. Read the message and follow the instructions carefully. WARNING: Indicates a potentially hazardous situation which, if not avoided, can result in serious injury or death. CAUTION: Indicates a potentially hazardous situation which, if not avoided, can result in minor to moderate injury, or serious damage to the product. The situation described in the CAUTION may, if not avoided, lead to serious results. WARNINGS DANGER OF ELECTRIC SHOCK. There are no user serviceable parts inside the Oasis DO NOT attempt to make repairs or alterations to the unit. WARNING: This equipment should be installed, adjusted, and serviced by qualified electrical maintenance personnel familiar with the construction and operation of the equipment and the hazards involved. Failure to observe this precaution could result in personal injury. CAUTIONS CAUTION: Always wear personal protective equipment (protective clothing, gloves, and safety boots) while performing an installation or maintenance, to avoid the danger of injuries. CAUTION: Proper grounds, disconnecting devices, e.g. bypass boxes and other safety devices and their location are the responsibility of the user and are not provided by MLT Drives CAUTION: Do not cover the device or store it in a small space - always keep it well ventilated and well away from flammable gases or powders. Components in the device could potentially cause a small electric spark that could ignite flammable gas or powders. Flammable gases are created by batteries and can become a hazard in poorly ventilated spaces. CAUTION: For indoor use only and MUST be installed in a dry area free from conductive liquids or conductive debris. If part of the inverter becomes submerged in water look for a safe way to isolate it at the distribution board and if possible at the batteries. PAGE 6 MAY 2012 ISSUE 01
7 1.2 Contacting MLT Drives Product Support When contacting Product Support via telephone, or fax please provide the following information for the fastest possible service: Type of Inverter Serial number Battery type Battery bank capacity Battery bank voltage A description of the error The above details (apart from the Description of the error should be available from your System Configuration sheet (see page 8). Note that the serial number is available on the serial plate that is attached to the bottom of the machine Contact Details Telephone: info@mltdrives.com Address: Telephone 97 Garfield Road Kenilworth 7000 Cape Town South Africa You can reach technical support by telephone directly Monday to Friday between 08h00 and 16h30 (GMT +2 hours). Queries outside of these hours should be directed to techsupport@mltdrives.com and will be answered at the earliest opportunity. When contacting technical support, please ensure that you have the information listed above available. MAY 2012 ISSUE 01 PAGE 7
8 1.3 System Configuration The system configuration table below should be completed by the installer after installing your Oasis 6000 system. We recommend that you check that it is completed as it contains most of the information needed when contacting MLT Drives for assistance. Item Parameter Description 1. System Type Oasis 2. Serial Number 3. Battery Type 4. Battery Bank Capacity Ah 5. Battery Bank Fuse Fitted Yes No Rating = A PAGE 8 MAY 2012 ISSUE 01
9 1.4 Specifications AC Output specifications AC Output Unit Oasis 6036 / Oasis 6048 Voltage V 230 Volts ±2 %, Single Phase, 2 Wire Output. Frequency Hz 50 Continuous output power kva 6 Rated output current A 26 Maximum output current A 39 (for 30s), 52 (for 2s) THD V (at rated power) % < 5 Surge protection Yes, Between Phases and to Ground Short circuit protection Internal Protection System (using electronic detection) Control Type Waveform Yes Continuous Overload Protection Short Circuit Protection Heat-sink over temperature Over/Under Battery Voltage Reverse-power protection Voltage Source, Microprocessor Regulated Pure sine-wave, low THD AC Input specifications AC Input Unit Oasis 6036 / Oasis 6048 Rated voltage V , Single Phase, 2 Wire Input Rated frequency Hz Rated input current A DC specifications Battery Input Unit Oasis 6036 Oasis 6048 Battery Voltage (Nominal) V Short Circuit Protection Yes, Fused Yes, Fused Charging Voltage V 42.3 / 44.1 (User 56.4 / 58.8 (User selectable) Charging current A 30 / 60 (User selectable) selectable) 25 / 50 (User selectable) MAY 2012 ISSUE 01 PAGE 9
10 1.4.4 General technical specifications System Unit Oasis 6036 Oasis 6048 Efficiency % Up to 94 Up to 94 No load power consumption (Manual W <40 (0.8 A Typical) <40 (0.7 A Typical) mode) No load power consumption (Auto mode) W 6 6 General technical specifications EMI Installation Mounting method Cooling method Enclosure Colour Unit Oasis 6036 / Oasis 6048 Designed to minimise both conducted and radiated EMI emissions Suitable for indoor installation only Wall mounted Convection Cooled (Heat-sink) Forced air ventilation(internal components) Air intake at bottom Air discharge through the enclosure sides IP30 Not Weatherproof Cadac Blue Connectors Oasis 6036 / Oasis 6048 Load Output Terminal Blocks for 10 mm 2 wire with bootlace ferrule Input DC (Battery) Cable terminal for 35mm 2 x10 lugs per pole (positive and negative) Operator Panel Oasis 6036 / Oasis 6048 User Input 3 position rocker switch to select one of the following modes: System Off Manual mode Auto mode Display Type 3 LED s. See Status indicators on page 22 PAGE 10 MAY 2012 ISSUE 01
11 1.4.5 Climatic conditions Climatic conditions Unit Oasis 6036 / Oasis 6048 Ambient temperature C (continuous operation) Ambient temperature for C transport Maximum ambient for C 45 continuous rated power Relative humidity % (Non-condensing) Maximum altitude above sea level for rated power at rated temperature m 1000 (See power de-rating graph on page 11 for altitudes higher than 1000m) Figure 1: De-rating the Oasis 6000 output power at high altitude MAY 2012 ISSUE 01 PAGE 11
12 1.5 System Description MLT Oasis 6000 series systems are mechanically and electrically robust and tough, with a wide operating temperature range suitable for operation in harsh environments. The Oasis 6000 has a 150% overload capacity and is the perfect fit for low maintenance, off grid, remote installations. A typical Oasis 6000 system application is shown below in Figure 2 involving the integration of generator backup power, solar energy and batteries Solar Array Fuse Solar Regulator Generator Fuse Fuse Battery Bank Load Figure 2: Typical Oasis 6000 System The Oasis 6000 system integrates a battery charger with a standalone inverter, so that power is supplied to the local load from the batteries and renewable energy until a generator or utility become available, the load is then connected to the generator or utility and the Oasis 6000 switches to charging mode. In charging mode, the Oasis 6000 will attempt to charge the batteries with the maximum allowed current. If however the load on the Oasis 6000 is large, it will reduce the charging current to prevent the generator from being overloaded. If the generator is still too small to supply the charging current and/or the load, and drops out within the first 5 minutes of charging, the Oasis 6000 will reduce the maximum charging current and try to connect again. This will continue until the generator remains connected. If this has happened due to a large load and the charging current has been greatly reduced, pressing the Reset button on the front panel will restore the charging current to its original value. See 3.5 Battery charger settings on page 26 for details on selecting the maximum charging current and voltage. PAGE 12 MAY 2012 ISSUE 01
13 If a short circuit or continuous overload condition is present on the output of the Oasis 6000 it will switch off to protect itself, and indicate the error using the buzzer and the front panel LEDs. Once the Oasis 6000 has turned off due to an overload or short circuit error, it will wait 10 seconds and then re-start. If the fault condition is still present after three attempts, it will remain off and the Reset button will need to be pressed before it will restart. Make sure to remove the cause of the overload or short circuit before pressing the Reset button. For a complete description of all the possible faults and operational modes that can be displayed on the LEDs, refer to Status indicators on page 22. MAY 2012 ISSUE 01 PAGE 13
14 Figure 3: Identifying parts of the Oasis 6000 PAGE 14 MAY 2012 ISSUE 01
15 2. Setup and Operation 2.1 Installing the Oasis 6000 For optimal performance, please refer to the following instructions regarding the installation and setup of your newly purchased Oasis Selecting a suitable location When selecting a location to mount your Oasis 6000, take note of the following: 1) The Oasis 6000 should be mounted in a well-ventilated area out of direct sunlight. 2) The Oasis 6000 is designed to be wall-mounted, and must therefore be installed upright to allow sufficient cooling. Operating the Oasis 6000 while it is lying flat will cause it to heat excessively. 3) The battery leads should be as short as possible, so the Oasis 6000 will need to be near to the batteries. 4) While charging the batteries, the Oasis 6000 will emit an audible hum. This should be taken into account when selecting a suitable location. Note: At high altitudes the cooling of electrical equipment is degraded by the reduced ability of the thinner air to remove heat from the heatsink. In accordance with the standards, the Oasis 6000 is rated for altitudes up to 1000m above sea level. If it is going to be installed in an area where the altitude is greater than 1000m above sea level, refer to the power de-rating graph (Figure 1) to establish the maximum continuous load Mounting The Oasis 6000 is designed to be wall-mounted. Once a suitable location has been chosen, use the following information as a guide to make the mounting process easier: 1) Using a 14mm masonry drill bit, drill 4 holes 55mm deep using Figure 4 on page 16 as a guide. 2) Insert the M8 rawl bolts (Figure 5) into the holes, and tighten with a 13mm spanner. 3) The spacers supplied on the shaft of the bolt should ensure that there is a 2 4mm gap between the washer and the wall (Figure 6). 4) Holding the Oasis 6000 vertically, lift it onto the bolts, so that the hanging bars fit between the washers and the wall (Figure 7). Caution: The Oasis 6000 is quite heavy; dropping it could result in personal injury and damage to the machine. It is therefore recommended that this step be performed by 2 people. MAY 2012 ISSUE 01 PAGE 15
16 300mm 340mm Figure 5: M8 Rawl bolt Figure 4: Positioning the mounting holes Figure 6: Detail of mounting bolt Figure 7: Detail of hanging bar Figure 8: Removing the user interface connectors PAGE 16 MAY 2012 ISSUE 01
17 2.1.3 Making the electrical connections Once your Oasis 6000 has been mounted on the wall, you can begin making the electrical connections. Follow these steps to make the task as simple as possible. Caution: Failure to follow these instructions carefully could increase the risk of personal injury, death or damage to property or equipment. If in doubt about anything, contact MLT Drives for assistance. 1) Remove the 14 screws that secure the front cover, taking care not to let the cover fall when removing the final screws. 2) Carefully pull the cover towards you until you have access to the user interface connectors (Figure 3). 3) Disconnect the cables from the user interface connectors by pushing the tab gently away from the connector and pulling the plug out. (See Figure 8) 4) Once both connectors have been removed, the front panel can be put aside. 5) The Load connections inside the Oasis 6000 will need to be connected into your distribution board to provide power to your house. These connections should be made with 6mm² cables, which can be brought in from the bottom of the machine through the cable-gland provided. Take care to connect the Live wire to the L terminal and the Neutral wire to the N terminal. 6) If you are installing a generator, make sure it is switched off and any Automatic starting circuitry is disabled before continuing. Referring to Figure 9, bring 6mm² cables through the cable gland provided into the Generator terminals of the Oasis 6000, taking care to connect the Live wire to the L terminal and the Neutral wire to the N terminal. While every attempt has been made to insure the safety and reliability of the Oasis 6000, there is a chance that connecting the generator incorrectly could cause damage to the unit. 7) If the Oasis 6000 is being used without a generator, the Generator Neutral terminal inside the unit must be connected to the Earth so that external earth-leakage protection devices can operate correctly. In installations with a generator, the generator chassis must be grounded to the same earth as the Oasis ) The Earth terminal inside the Oasis 6000 must be grounded to reduce the risk of electrical shock and to ensure that external earth-leakage protection device can operate correctly. 9) The Oasis 6000 comes from the factory with battery leads pre-installed. It is not recommended that these be removed or lengthened. If, however, replacing the DC cables is unavoidable, make sure to use cables of the same size and rating (35mm²) to avoid any problems. MAY 2012 ISSUE 01 PAGE 17
18 10) Caution: Once all the internal electrical connections have been made check that they are secure, as a loose connection could get hot enough to cause a fire. Note: External protection devices such as fuses, circuit breakers and earth-leakage protection are the responsibility of the owner, and not of MLT Drives. MLT Drives cannot be held responsible for personal injury, death or damage to property or equipment caused by the improper use or installation of this equipment. It is therefore recommended that all the electrical connections must be made by a qualified electrician or an MLT Drives approved installer. Figure 9: AC Input/output Connections on the Oasis 6000 PAGE 18 MAY 2012 ISSUE 01
19 2.1.4 Setting up the Oasis 6000 After making the electrical connections and before powering up your Oasis 6000 for the first time, it is recommended that you follow the instructions in 3.5 Battery charger settings on page 26. Once the settings are correct, the front panel must be replaced, taking care to reconnect the cables to the user interface connectors. Secure the front panel by replacing the screws Powering up the Oasis ) Make sure all source (Generator or utility) and load AC wires and the DC cables are connected correctly and securely inside the Oasis 6000, and that the front cover is secured. 2) Make sure the rocker switch on the front panel of the Oasis 6000 is in the Off position. 3) Connect the Negative battery cable to the Negative (-) terminal of the battery. 4) Put the pre-charge cable onto the Positive (+) terminal on the battery and hold it there for about ten seconds, this will pre-charge the DC capacitors inside the Oasis 6000 so that there is no spark when the Positive cable is connected. 5) Leaving the Pre-charge cable on the Positive (+) terminal of the battery, connect the Positive cable onto the Positive (+) terminal on the battery as well. See Figure 11. 6) Make sure the battery connections are secure. 7) Put the rocker switch into the desired position, i.e. Either Auto or Manual to start the Oasis Powering down the Oasis 6000 If it is necessary to turn off or disconnect your Oasis 6000 for some reason, follow these simple steps: 1) Put the rocker switch into the Off position. 2) If a source such as a generator or utility is connected, make sure it is turned off. 3) If required, the Oasis 6000 can now be disconnected from the batteries. 4) Once disconnected from the batteries, connect the Pre-charge cable to the Negative cable, this will discharge the DC capacitors inside the Oasis ) If required, the front cover of the Oasis 6000 can now be removed. WARNING: There is the possibility of dangerously high voltages inside the Oasis 6000 if the connected Generator or Utility is not turned off. MAY 2012 ISSUE 01 PAGE 19
20 Figure 10: DC cables Figure 11: Oasis 6000 DC connections PAGE 20 MAY 2012 ISSUE 01
21 2.2 Operation of the Oasis 6000 The Oasis 6000 has been designed to be very simple to operate. The entire user interface consists of only three LEDs, a rocker switch and a reset button. This section explains the function of each of these items The user interface Figure 12: Oasis 6000 Front panel LEDs The LEDs are used to indicate the status of the Oasis 6000, refer to Status indicators on Page 22 for a complete description of the functions of the LEDs. Rocker switch Put this switch into the Auto position to enable automatic load sensing, where the Oasis 6000 will go into a low power standby mode when there is no load connected. Putting this switch into the Off position will turn off the output of the Oasis Note: All power to the load will be lost. Put this switch into the Manual position to force the Oasis 6000 to run regardless of the presence of a load. MAY 2012 ISSUE 01 PAGE 21
22 Reset button Operational Modes Press the reset button to re-start the Oasis 6000 if it has turned off due to a fault. Note: Make sure to remove the cause of the fault before resetting the Oasis Off: In Off mode, the Oasis 6000 will stop supplying power to the load and charging the battery. Auto: In Auto mode the Oasis 6000 will run in a low power standby mode if no load is connected. This helps to reduce the current drawn from the batteries while the Oasis 6000 is not in use. If a load greater than 20W is switched on, the Oasis 6000 will detect it and start up automatically. If a source is connected, the Oasis 6000 will use the source to power the load and charge the batteries. Manual: In this mode the Oasis 6000 will run continuously, even if there is no load connected. If a source is connected, the Oasis 6000 will use the source to power the load and charge the batteries. Battery charging: If a source (Generator or Utility) is connected while the Oasis 6000 is in either Auto or Manual mode, the Oasis 6000 will connect the load directly to the source and begin charging the batteries. When the battery charging is complete, the Oasis 6000 will stop charging but leave the load powered by the source until the source is stopped, at which point the Oasis 6000 will resume supplying power to the load from the batteries Status indicators The LED s on the front panel along with the audible alarm indicate the status of the Oasis The following table describes all of the possible combinations. Indicators Inverter status Required Action (If any) All LEDs flashing in alternating Red, Yellow, Green pattern Green LED lit Green LED flashing slowly. (On for about 1 second every 3 seconds) The Oasis 6000 is connected to the batteries and has power, but is in the Off mode. The Oasis 6000 is operating normally, supplying power to the load. The Oasis 6000 is in a low power standby mode. If a load is turned on, the Oasis 6000 will start automatically. Putting the Oasis 6000 into Auto or Manual mode will cause it to start. PAGE 22 MAY 2012 ISSUE 01
23 Green LED flashing quickly. Yellow LED flashing and audible alarm beeping. Yellow LED lit and audible alarm beeping. Yellow LED pulsing briefly every 2 seconds. Red LED flashing and audible alarm beeping. Red LED lit and audible alarm beeping. All LEDs flashing simultaneously. Red and Yellow LEDs flashing, and audible alarm beeping. Three short beeps every 2 seconds. Red and green LEDs lit and audible alarm sounding continuously. The Oasis 6000 is busy charging the batteries. Once the charge cycle is complete, the Green LED will stop flashing. The Oasis 6000 has overheated. The battery voltage is too low, and the Oasis 6000 has turned off to protect the battery. The Oasis 6000 is currently connected to an external AC source, which is being used to power the load. The battery voltage is very high. The Oasis 6000 has shut down to protect itself. There was a continuous overload or short circuit condition on the output of the Oasis The generator voltage is out of range. The external AC source is connected to the Load terminals of the Oasis The battery voltage is low and the Oasis 6000 will turn off shortly. The Oasis 6000 is overloaded, and will switch off shortly. Allow the Oasis 6000 to cool down, and it will restart automatically. Charge the battery. Find and remove the cause of the high battery voltage (Usually an external wind or solar charger). Remove the excess load or the cause of the short and press the Reset button. Find the cause of the incorrect generator voltage, and correct it. Turn off the AC source (generator or grid) and the Oasis 6000, and correct the wiring fault. To avoid a loss of power, charge the batteries and/or remove excess loads. To avoid a loss of power, turn off excess loads. MAY 2012 ISSUE 01 PAGE 23
24 2.3 Connecting an external AC source Follow these steps when connecting an external AC source such as a generator or utility to ensure your safety Preparation Before starting the installation ensure that you read the owner s handbook for the generator that you are installing and that you are fully aware of requirements such as minimum cable size and generator siting information. MLT Drives recommends using 6mm² wire to connect your generator to your Oasis Installing a Generator 1) Power down the Oasis 6000 by completing the instructions in Powering down the Oasis 6000 on page 19, taking care to disconnect the user interface connectors when removing the front panel. 2) If a generator or utility is connected, double check that it is OFF and any Automatic starting circuitry that could cause the generator to start is disabled. 3) Referring to Figure 9, bring 6mm² cables from the generator or utility through the cable gland provided into the Generator terminals of the Oasis 6000, taking care to connect the Live wire to the L terminal and the Neutral wire to the N terminal. While every attempt has been made to insure the safety and reliability of the Oasis 6000, there is a chance that connecting the generator incorrectly could cause damage to the unit. 4) Make sure to ground the generators chassis to the same Earth connection as the Oasis ) Once all the internal electrical connections have been made, check that they are secure as a loose connection could get hot enough to cause a fire. 6) The front cover must now be replaced taking care to re-connect the cables to the user interface connectors. 7) Replace the 14 screws that secure the front panel. 8) Follow the instructions in Powering up the Oasis 6000 on page 19 to re-start your machine. PAGE 24 MAY 2012 ISSUE 01
25 3. About Batteries 3.1 General A number of lead acid batteries are used together to form the battery bank for the Oasis Basically there are two types of lead acid battery that can be used as follows: Standard, Gel, Sealed or Low Maintenance battery which is another name for a normal car battery. This type of battery is designed to provide a large current for a very short period of time. They are not designed to be regularly discharged by more than 25% of their capacity. This battery is suitable for backup applications. Deep cycle lead acid batteries are designed to be repeatedly discharged to at least 50% of their capacity, which makes them suitable for homes using solar power or off-grid power use. Thus if in your application you are repeatedly charging and discharging your batteries you should be using deep cycle batteries. If, however, you are using your system as a UPS, low maintenance batteries may be sufficient. Standard batteries can be flooded batteries which require regular maintenance or sealed which are maintenance free. Deep cycle batteries are available only in the flooded variety. If standard batteries are suitable, maintenance free type should be selected as they do not require topping up of their electrolyte during their life. Your Oasis 6000 will have either a 36 or 48 volt battery bank while the number of batteries will depend on the capacity required. Batteries will be connected in series to give the required 36 or 48 volts. Further strings of batteries may be connected in parallel with the first group to increase the capacity of the battery bank. 3.2 Battery Bank Location When selecting a suitable location for your battery bank, take the following into consideration: Batteries MUST be installed in a well-ventilated environment away from direct sunlight Ensure that the battery leads are as short as possible for maximum efficiency and avoid extending the battery cables that ship with your Oasis A Battery Fuse MUST ALWAYS be installed and be as close as possible to the batteries! ALWAYS observe the electrical wire colour coding convention i.e. connect the red wire to POSITIVE, and the black wire to NEGATIVE MAY 2012 ISSUE 01 PAGE 25
26 3.3 Maintenance Battery maintenance required will be detailed in the documentation supplied with the battery and for flooded batteries generally includes checking of the electrolyte levels on a regular basis and topping up with distilled water when necessary Providing it is maintained and sited correctly, a good quality battery should last at least 3 year s continuous use before needing replacement. 3.4 Replacing a Battery Always replace a battery with a battery of the same type and capacity. Never replace a flooded battery with a maintenance free battery or vice-versa. If you are not sure about the type and capacity of the batteries installed refer to the System Configuration guide on page 8. To replace a battery: 1) Follow the instructions for Powering down the Oasis 6000 on page 19 2) Taking care not to short circuit the battery terminals, disconnect and remove the faulty battery. NOTE: To prevent short circuits it is recommended that you always use an insulated spanner when connecting or disconnecting individual batteries or battery banks. 3) Place the new battery in position and connect and tighten positive and negative connections (red positive, black negative). 4) Repeat steps 2 and 3 for any other batteries that need replacing. 5) Replace Battery Fuse and, if applicable, Solar Array Fuse. 6) Follow the instructions for Powering up the Oasis 6000 on page Battery charger settings It is important to select the correct charging current and voltage for your batteries during the installation of your Oasis 6000, also if you increase or decrease your battery capacity or replace the battery bank with a different type of battery it may be necessary to change the battery charger settings. Before removing the front cover or making any adjustments, follow the instructions on page 19 for powering down and discharging your Oasis PAGE 26 MAY 2012 ISSUE 01
27 3.5.1 Selecting the battery charging current The battery charging current can be set by the charging current select jumper (see Figure 5) on the control card inside the Oasis The jumper selects between 25A and 50A for the Oasis6048 or 30A and 60A for the Oasis Note that the actual charging current will depend on the battery voltage and the load. Figure 13 shows all the possible jumper configurations. The Oasis 6000 always ships with the jumpers removed as in Figure 13A. The battery charging current should not be set to more than 15% of the nominal Ah capacity of your batteries Selecting the battery charging voltage The battery charging voltage can be set by the charging voltage select jumper (see Figure 13) on the control card inside the Oasis The jumper selects between 56.4 and 58.8V on an Oasis 6048 or 42.3 and 44.1V on an Oasis Figure 13 shows all the possible jumper configurations. The Oasis 6000 always ships with the jumpers removed as in Figure 13A. Generally Standard, Gel, Sealed or Low Maintenance batteries should be charged at the lower voltage setting, and flooded Deep cycle batteries should be charged at the higher voltage setting. Figure 13: Selecting the charging current and voltage. MAY 2012 ISSUE 01 PAGE 27
28 4. About Solar Panels 4.1 Introduction The term solar panel refers to a panel comprising a number of Photovoltaic (PV) cells which convert sunlight into electricity.. Solar panels are a source of renewable energy which is becoming increasingly accessible. As with most renewable systems solar panels are unable to provide energy at all times as there may be insufficient sunlight available. To fill the gaps, electricity can be supplied from storage batteries or generators in stand-alone systems or from the electricity grid in grid connected systems. 4.2 Using a Solar System with the Oasis 6000 If you are considering adding a solar system to your installation, contact MLT or the person who installed your system for advice on the type of solar regulator you should use and for details on its installation. CAUTION: DO NOT connect solar panels directly to the batteries, a solar regulator must be used, otherwise damage to the batteries and or Oasis 6000 could result. PAGE 28 MAY 2012 ISSUE 01
29 5. Trouble Shooting 5.1 Faults If there is a fault with the Oasis 6000, the LEDs and audible alarm will indicate what fault has occurred. Refer to Status indicators on Page 22 for a complete list of faults and the action required to correct them. If you have a fault that is not addressed in this manual then you should contact the person who installed your Oasis 6000 or, alternatively, MLT Drives product support. See Contacting MLT Drives on Page Typical Problems Why does the Oasis 6000 not connect to a running generator? Check that any circuit breaker on the generator is in the up position, and the Oasis 6000 is in either Auto or Manual mode. If the generator voltage is very low or high, all three LED s on the front of the Oasis 6000 will begin flashing simultaneously. If this happens, check the generator output to ensure that it is operating correctly. If the generator is operating normally, check the wiring between the generator and the Oasis 6000 for a fault. The allowable input voltage range can be found in the specifications on page 9. Why does the generator connect and then immediately drop out? This could be caused by overloading of the generator. Check that the generators rated capacity is large enough to supply the load that is connected to the Oasis Turn off some loads if necessary. If the generator is very small and drops out soon after the Oasis 6000 begins charging, the Oasis 6000 will reduce the charging current before re-starting the charging cycle. If this has happened due to a large load on the output of the Oasis 6000, the charging current may be very low; pressing the reset button on the front of the Oasis 6000 will restore the charging current to that set by the jumper. (Refer to Selecting the battery charging current, on Page 27). Why didn t I get the usual capacity from my storage batteries? Were the batteries fully charged to start with? To ensure a consistent performance from the batteries it is important that they are charged correctly. Each battery type (flooded deep cycle, sealed, gel etc.) has different charging requirements. Incorrect adjustment of battery settings is the most common cause of reduced backup time from your batteries. For Flooded Lead Acid Batteries it is important to check the battery electrolyte level periodically. Never leave the battery cells with the electrolyte below the required level. One or more of the batteries in the battery bank could be faulty. Check the batteries in accordance with the manufacturer s documentation and replace as necessary. MAY 2012 ISSUE 01 PAGE 29
30 Flooded lead-acid batteries can be checked with a hydrometer. All batteries should measure the same specific gravity ±10%. Sealed batteries can be tested with a multi-meter. All batteries should measure the same voltage. Why doesn t my Oasis 6000 wake up when I switch on a load? Is the load large enough? The load sensing feature of the Auto mode requires a minimum load of 20W to be connected before the Oasis 6000 will start. A single cellphone charger, for example, is not large enough. Try switching on a light bulb or TV to increase the load, or putting the Oasis 6000 into Manual mode. A typical compact fluorescent or Energy saver light bulb uses about 11W. PAGE 30 MAY 2012 ISSUE 01
31 6. Glossary AC DC Generator Grid/Utility PV SRC or SOURCE Wind Turbine Alternating current. The utility, generators, and inverters can supply AC. The AC voltage to homes in South Africa is described as 230V AC 50Hz meaning 230V RMS that is alternating between a positive voltage and a negative voltage 50 times a second. Direct current. Batteries, solar panels (PV) and some wind turbines provide DC. The Oasis 6000 can take DC from batteries and output 230V AC to supply homes and businesses. This is a machine that usually runs off diesel or petrol to provide AC power. Generators are usually only run when needed. Generators need to be run periodically to keep their moving parts functional. Generators usually provide most power per litre when they are electrically loaded to 80% of their rating. This is an AC power source that is usually will be present most of the time. The utility is often provided by some power producing company and is not always reliable due to lack of capacity. Photo voltaic cell. Also known as solar panels. PV cells generate DC electricity when sunlight strikes them. A source (abbreviated as SRC) is the general definition for an AC supply such as the Grid or a Generator. This is a modern form of wind mill. Wind turbines generate electricity when their blades are rotated by the wind. Wind turbines usually generate DC. MAY 2012 ISSUE 01 PAGE 31
CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...
CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. INVERTER OPERATION... 11 6. TROUBLE SHOOTING GUIDE....... 16 7.
More informationCONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9
USER MANUAL 1 CONTENTS 1. INTRODUCTION... 1 2. SAFTY INSTRUCTION... 3 3. CABLE CONNECTION... 4 4. SYSTEM DESCRIPTION... 5 5. OPERATION... 9 6. TROUBLE SHOOTING GUIDE... 25 7. OPERATION MODES..... 27 8.
More informationUSER MANUAL MPS 1-5KW SERIES
USER MANUAL MPS 1-5KW SERIES Low Series Frequency Solar and Wind Power Charging Inverter CONTENTS 1 WWW.NEXTGENNRG.COM 1. Introduction... 3 2. Profile Structure 4 2.1. Working Principle 4 2.2.Product Features..5
More informationPure Sine Wave Inverter Charger
Pure Sine Wave Inverter Charger Renogy 1000W 2000W Pure Sine Wave Inverter Charger Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.6 1 Important Safety Instructions Please save
More informationAUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465
AUTOMOTIVE POWER INVERTERS INSTRUCTIONS Item #31463, #31464, #31465 EASTWOOD AUTOMOTIVE POWER INVERTERS are heavy-duty professional grade pieces of equipment designed to bring 120 volt power to any automobile.
More informationBattery Power Inverters
Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.4 Important Safety Instructions Please save these instructions.
More informationUSER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER
USER'S GUIDE WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER LEN.MAN.STA.145 Rev.5.00/2010 CONTENTS 1. SAFETY INSTRUCTIONS 1 2. INTRODUCTION 2 3. FRONT PANEL AND INSIDE
More informationLow Frequency Inverter. User Manual
Pure Sine Wave 220-240V 50-60Hz Low Frequency Inverter User Manual For LK/LW series Power Star inverters only, models: LK2000, LK2000-24, LK3000, LK3000-24, LK3000-48, LK6000-24, LK6000-48 1. Safety precautions
More informationUser Manual 1KVA-5KVA INVERTER / CHARGER
User Manual 1KVA-5KVA INVERTER / CHARGER Version: 1.7 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationUser Manual Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...
More informationUser Manual. Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5
More informationUser Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER
User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture... 2 Product Overview...
More information10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL
10A / 15A / 20A Solar Charge Controller PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL Dear Customer, Thank you very much for choosing our product. This manual contains important information about
More informationUser s Manual. Automatic Switch-Mode Battery Charger
User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service
More informationUser manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger
User manual Solar Hybrid 1-5KVA Uninterruptible Power Supply / Charger All rights reserved. The information in this document is subject to change without notice. Thank you for purchasing this series UPS.
More informationGeneral Precautions. Personnel Precautions
USER MANUAL General Precautions 1. Before using Inverex, read all instructions and cautionary markings on : (1) Inverex (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only
More informationDuo Battery Charge Controller
Duo Battery Charge Controller RENOGY 10A 20A Pulse Width Modulation Solar Charge Controller Manual 1 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678 Version: 1.2 Important Safety Instructions
More informationUser Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1
User Manual 1.5KVA-3KVA INVERTER / CHARGER Version: 1.1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationSOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan
SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA Appliances 420-00300-02 PC TV Light Electricfan Table Of Contents GENERAL PRECAUTIONS... 1 PERSONNEL PRECAUTIONS... 1 INTRODUCTION...
More informationBRAVER UPS. (Uninterruptible Power System) User s Manual
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
More informationUser Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3
User Manual 5KVA/5KW INVERTER / CHARGER Version: 1.3 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationUSER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4
USER S MANUAL PowerWalker VFI 1000 / 3000VA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION......... 2 3. SYSTEM DESCRIPTION......... 4 4. CABLE CONNECTION......... 7 5. OPERATION...... 8 6. TROUBLE
More informationUser Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER
User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER WWW.POWERHIGHWAY.NET CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS...... 1 INTRODUCTION... 2 Features... 2 Basic System
More informationOWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.
OWNER S MANUAL DP AUDIO Model No. DN350 12 Volt DC to 115 Volt AC 150 WATT 300WATT HIGH SURGE POWER INVERTER Please read installation and operation instruction before using this Power inverter. Contents
More informationPOWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System
POWER TROLLEY 8 Model: SINE 1548 Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System Version 07 CONTENTS Page 1. INTRODUCTION... 1 2. USING THE POWER TROLLEY.... 2 3. BATTERY BACKUP
More informationUSER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment
USER MANUAL FOR 2000 WATTS POWER INVERTER Your 2000 watts power inverter converts 12-volt vehicle battery power into 230 volts of AC power. You can use the inverter in your vehicle to operate many types
More informationUser Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller
User Manual 4KVA/ 5KVA INVERTER / CHARGER With MPPT Controller CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationMPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4
User Manual 800W-4000W Hybrid solar inverter Version: 1.4 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationATD WATT INVERTER
ATD-5954 1500 WATT INVERTER Welcome. This ATD product has been carefully engineered and manufactured to give you dependable operation. Please read this manual thoroughly before operating your new ATD product,
More informationUser Manual WT Combi-S Pure Sinus Wave Inverter
User Manual WT Combi-S Pure Sinus Wave Inverter Contents 1. Important Safety information 1.1. Safety Information part 1 1.2. Safety information part 2 2. General Features 2.1. Product overview 3. Connection
More informationSOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V
SOLAR LIGHTING CONTROLLER OPERATOR S MANUAL SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V 10A / 12V 10A / 24V 20A / 12V 20A / 24V 1098 Washington Crossing Road Washington Crossing,
More informationc-go 12V/10A 12V/20A Power supply and battery charger Instruction manual
c-go 12V/10A 12V/20A Power supply and battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Mounting and installation... 4 4. Operation... 5 5. Problem solving...
More informationUSER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4
USER S MANUAL ON-LINE 1K/2K/3KVA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. UPS OPERATION...... 12 6. TROUBLE
More information15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries
15Amp Intelligent Battery Charger Suitable for SLA, Gel, Maintenance Free, AGM, Deep Cycle batteries MB-3622 READ THESE INSTRUCTIONS BEFORE USE AND RETAIN FOR FUTURE REFERENCE! 1 CAUTION! When working
More informationInverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.
Inverter / Charger Accessory for Steca Solarix PLI 5000-48 3-Phase / Parallel Kit Installation and operating instructions GB Z01 17.31 Table of Contents About this Manual... 2 Purpose... 2 Scope... 2 Keywords
More informationUser Manual 1KVA-5KVA INVERTER / CHARGER
User Manual 1KVA-5KVA INVERTER / CHARGER Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture... 2 Product
More informationThe Traveler Series: Wanderer
The Traveler Series: Wanderer RENOGY 30A PWM Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version: 2.3 Important Safety Instructions Please save these instructions.
More informationDC TO AC POWER INVERTER
DC TO AC POWER INVERTER 12V / 24V / 48Vdc Input 115V / 230Vac Output 150W ~ 6000W Output cont. L-Series User Manual Before install and use your Inverter, read the User Manual and safety instructions. Cooler
More informationSinergex. PureWatts Elite 150. User's Manual. Sinergex Technologies L.L.C. (USA) Website:
Sinergex PureWatts Elite 150 User's Manual Sinergex Technologies L.L.C. (USA) Website: www.sinergex.com Email: info@sinergex.com WELCOME Thank you for purchasing a Sinergex PureWatts Elite 150 power inverter.
More informationSolar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C
Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5
More informationPhoenix Inverter
Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC
More informationSolar Hybrid Inverter SP Brilliant Series
User Manual Solar Hybrid Inverter SP Brilliant Series Version: 1.5 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System
More informationGSL Electronics Modified Sine Wave Power Inverters
GSL Electronics Modified Sine Wave Power Inverters Congratulations on choosing one of our Modified Sine Wave Inverters for your application. There are 6 models in the range, which will meet most of your
More informationThe purpose of this document is to help familiarize you with some of the terminology, definitions and system types used. It helps to answer some of
The purpose of this document is to help familiarize you with some of the terminology, definitions and system types used. It helps to answer some of the questions frequently asked by customers. Contents
More informationThe Traveler Series: Adventurer
The Traveler Series: Adventurer RENOGY 30A Flush Mount Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.2 Important Safety Instructions Please save these instructions.
More informationUser Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1
User Manual 3KVA-5KVA INVERTER / CHARGER Version: 1.1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More information1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3
1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER User Manual Version: 2.3 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features...
More informationTurbo M Series onboard charger
Turbo M Series onboard charger Operation Manual Model # Output Bank Max. Output Turbo M106 1 6 Amps Turbo M108 1 8 Amps Turbo M208 2 8 Amps Turbo M212 2 12 Amps Turbo M220 2 20 Amps Turbo M230 2 30 Amps
More informationUser Manual. 3kW Hybrid PV Inverter HX-3000
User Manual 3kW Hybrid PV Inverter HX-3000 Table Of Contents 1. Introduction...1 2. Important Safety Warning...2 3. Unpacking & Overview...4 3-1. Packing List... 4 3-2. Product Overview... 4 4. Installation...5
More informationSolar Hybrid Inverter SP Efecto Series
User Manual Solar Hybrid Inverter SP Efecto Series Version 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationUser Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0
User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER Version: 1.0 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationVLT SERIES. True Sine Wave AC Power Inverter. Owner s Manual. Owner s Manual D Rev.B
Owner s Manual VLT SERIES True Sine Wave AC Power Inverter 60Hz Models VLT12-600 VLT12-1000 VLT12-1500 VLT24-600 VLT24-1000 VLT24-1500 VLT48-1000 VLT48-1500 50Hz Models VLTE12-600 VLTE12-1000 VLTE12-1500
More informationOn Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual
On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains
More informationThe Traveler Series: Wanderer
The Traveler Series: Wanderer RENOGY 30A Charge Controller Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 2.0 Important Safety Instructions Please save these instructions. This
More informationATD WATT INVERTER
ATD-5955 2000 WATT INVERTER Welcome. This ATD product has been carefully engineered and manufactured to give you dependable operation. Please read this manual thoroughly before operating your new ATD product,
More informationInstallation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z
Installation and operating instructions Solar charge controller MPPT 10 A / 20 A EN 1 Contents 1. About these instructions... 3 1.1 Applicability... 3 1.2 Users... 3 1.3 Description of symbols... 3 2.
More informationUser Manual 1.5KVA-3KVA INVERTER / CHARGER
User Manual 1.5KVA-3KVA INVERTER / CHARGER Version: 1.0 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationUSER MANUAL. GS Series Hybrid Inverter
USER MANUAL GS Series Hybrid Inverter CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 IMPORTANT SAFETY INSTRUCTIONS... 1 General Precautions... 1 Personal Precautions... 2 INSTALLATION... 3 Unpacking
More informationPure Sine Wave Inverter GP-HS1500. Owner s Manual
Pure Sine Wave Inverter GP-HS1500 Owner s Manual 2 Table of Contents Introduction 3 Specifications 4 Name and Main Function 5 Installation 7 Operation 9 Operating Limits 13 Troubleshooting 13 Maintenance
More informationArt. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2
SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...
More informationModels: SP3, SPSS3 Automatic Battery Charger
OWNERS MANUAL Models: SP3, SPSS3 Automatic Battery Charger PLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE. This manual will explain how to use the charger safely and effectively. Please read and
More informationLS0512 Solar Charge Controller
LandStar LS0512 Solar Charge Controller Nominal system voltage Maximum PV input voltage Nominal charge / discharge current 12VDC 35V 5A Contents 1 Important Safety Information... 1 2 General Information...
More informationDC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual
DC AC POWER INVERTER LIV 10 / LIV 20 / LIV 30 User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the Power Inverter. This
More informationInverter User Manual
Inverter User Manual -------------for standard model DC TO AC Power Inverter CONTENTS Safety First 1. Introduction 2. Installation Guidelines 3. Using the inverter 4. Troubleshooting 5. Specifications
More informationSOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine
SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA Appliances 420-00288-01 PC TV Airconditioning Fridge Washing machine Table Of Contents ABOUT THIS MANUAL...1 Purpose... 1 Scope... 1 SAFETY
More informationSP6. Automatic Battery Charger. Model
Model SP6 Automatic Battery Charger OWNERS MANUAL PLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE. This manual will explain how to use the charger safely and effectively. Please read and follow
More informationUsers Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B
Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:
More informationManual. BlueSolar Grid Inverter 1500 / / / / / 230
Manual EN BlueSolar Grid Inverter 1500 / 230 2000 / 230 2800 / 230 4000 / 230 5000 / 230 Before you start This manual contains important information regarding installation and safe operation of this unit.
More informationc-go 24V/6A 24V/8A 24V/12A
c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...
More informationUser Manual Back-UPS BX650CI-MS 230 Vac with AVR
User Manual Back-UPS BX650CI-MS 230 Vac with AVR Overview Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Read the Safety
More informationUSER MANUAL. PW Series Inverter / Charger
USER MANUAL PW Series Inverter / Charger CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 IMPORTANT SAFETY INSTRUCTIONS... 1 General Precautions... 1 Personal Precautions... 2 INSTALLATION... 3
More informationOutdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...
Contents 1 Introduction...1 2 Safety...4 3 Product Specifications...6 Outdoor UPS User Manual 4 Installation...8 4.1 Inspection...8 4.2 Installing the UPS Cabinet...8 4.3 Connecting the Power Supply...10
More informationYSmart Technology Co., Ltd. User Manual. GTI Grid Series. GTI Series Inverters for Grid-connected PV system
YSmart Technology Co., Ltd. User Manual Contact Us Address: No. 30 XinFeng Road,Potoubei Village,Ailian Town,Longgang Dist, Shenzhen 51872,P.R. China Tel: (86)755-85232255 Fax: (86)755-85232255 Email :
More informationHYBRID 5048E. Hybrid Inverter INSTALLATION AND OPERATION MANUAL. Version 2.0E
HYBRID 5048E Hybrid Inverter INSTALLATION AND OPERATION MANUAL Version 2.0E SAFETY INSTRUCTIONS Risk of Electric Shock Alternating Current (AC) and Direct Current (DC) sources are connected to this device.
More informationNature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual
Version 1.1 Version 2 Nature Power Inverters True Sinewave Inverter Modified Sinewave Inverter Owner s Manual!!!!!!!!!!! 38304 38204 For safe and optimum performance, the Power Inverter must be used properly.
More informationGeneral safety and installation information.
Read these instructions before connecting and using your PowerBright Pure Sine Power Inverters. Failure in observing this warning may result in injury to persons and damage to equipment. General safety
More informationPower Inverter 400 MW Owner s Manual
Power Inverter 400 MW 1204 Owner s Manual For safe and optimum performance, the Power Inverter must be used properly. Carefully read and follow all instructions and guidelines in this manual and give special
More informationV 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual
DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W Instruction Manual Introduction The AIMS Power 5000 Watt series inverters are the most advanced line of mobile DC to AC power
More informationCar Battery Charger Instructions for Use
BATTERY CHARGER 12Volt 4Amp FOR INDOOR USE ONLY Power Details: Input: 230-240Vac; 50Hz; 52W Output: 12V DC; 2.8A Maximum Charge Rate: 4A RMS Read these instructions before operating this car battery charger
More informationGP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:
Go Power! Manual GP-1000 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION 3 2. SPECIFICATIONS
More informationTOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS
INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...
More informationSCC-MPPT Solar Charge Controller
Table 4: Alarm point for low battery voltage table Model Alarm point SCC-MPPT-300 10.5 V SCC-MPPT-600 21.0 V Table 5: Charging hour table for reference Battery Capacity To 90% capacity @ 25A charging current
More informationDC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL
DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL 1 A. INTRODUCTION The AIMS Power pure sine inverter product line is used for back-up power. The pure sine product line is ideal for sensitive
More informationUsers Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B
Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com
More informationUSER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply
www.eaton.com/dxups USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply CONTENTS 1.Brief introduction 1 1.1 System and model description 1 1.2 Description of commonly used symbols
More informationTECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT
TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT 1.0 PURPOSE: 1. To charge the battery bank through Solar PV source and AC supply. 2. To invert and produce utility quality sine wave. 3. Inverters
More informationGo Power! Manual. GP-1750HD Inverter GP-2500 Inverter
Go Power! Manual GP-1750HD Inverter GP-2500 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION...
More informationSolar Hybrid Inverter SP Efecto Series
User Manual Solar Hybrid Inverter SP Efecto Series Version 1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationUser Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1
User Manual 1KVA-5KVA INVERTER / CHARGER Version: 2.1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationSMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY
SMT WITH MPPT TECHNOLOGY Installation and Operation Manual Model:SMT SMT Dimensions Specification Summary System Voltage 12 V/24V Rated Battery Current 12V, 5A 8A 10A 15A 20A 25A 24V, 5A 8A 10A 15A Rated
More information12V/25A BATTERY CHARGER MAINTAINER / JUMPSTARTER
12V/25A BATTERY CHARGER MAINTAINER / JUMPSTARTER OWNER S MANUAL Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic
More informationThe Traveler Series TM : Adventurer
The Traveler Series TM : Adventurer 30A PWM Flush Mount Charge Controller w/ LCD Display 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version: 3.4 Important Safety Instructions Please save
More information230VAC Power Inverter 400W Owner s Manual
400W 230VAC Power Inverter 400W Owner s Manual For safe and optimum performance, the Enerdrive epower Inverter must be used properly. Carefully read and follow all instructions and guidelines in this manual
More informationInstallation and Operating Instructions. Solar System Controller ISC3030
Installation and Operating Instructions Solar System Controller ISC3030 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s of the
More informationFlinSlim Lite Solar Hybrid Inverter 1KVA-5KVA USER MANUAL. Version: 1.3
1KVA-5KVA USER MANUAL Version: 1.3 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture... 2 Product Overview...
More informationSteca Solarix PLI. Inverter / Charger with Solar Charge Controller. Installation and operating instructions. Download manual at
Inverter / Charger with Solar Charge Controller Steca Solarix PLI Installation and operating instructions GB Z03 18.20 Download manual at www.steca.com Table of Contents About this manual... 1 Purpose...
More informationPulsar EXtreme CLA 1500C
www.mgeups.com MGE UPS SYSTEMS Pulsar EXtreme CLA 500C Installation and user manual 503998EN/AA - Page Introduction Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment.
More informationBack-UPS 650 VA 230 V with AVR (BX650CI-ZA)
Back-UPS 650 VA 230 V with AVR (BX650CI-ZA) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit