APS & APS
|
|
- Valentine Tate
- 5 years ago
- Views:
Transcription
1 POWER INVERTER APS & APS
2 Table of Contents Important Safety Information General Safety Precautions Precautions When Working With Batteries General Informtion Application Features Basis System Architecture Product Overview Installation Unpacking and Inspection Preparation Mounting The Unit Battery Connection AC Input/Output Connection Electrical Performance LCD Display Icons Relay connections for gate operator auto open/close functions Operating Mode Description Warning Code/Audible Alarm Troubleshooting Guide
3 Important Safety Information D í! wb Lb This manual contains important instructions for APS & APS models that shall be followed during installation and maintenance of the inverters. General Safety Precautions 1. Before installing and using the inverter/charger, read all instructions and cautionary markings on the inverter/charger and all appropriate sections of this guide. Be sure to read all instructions and cautionary markings for any equipment attached to this unit. 2. Install this unit away from direct sun light and where is not exposed to water sprinklers. 3. To reduce risk of fire hazard, do not cover or obstruct the ventilation openings. Do not install the inverter/charger in a zero-clearance compartment. Otherwise overheating may occur.\ 4. Use only attachments recommended or sold by the manufacturer. Doing otherwise may result in a risk of fire, electric shock, or injury to persons. 5. To avoid a risk of fire and electric shock, make sure that existing wiring is in good condition and that wire is not undersized. Do not connect the inverter/charger with damaged or substandard wiring. 6. Do not operate the inverter/charger if it has received a sharp blow, been dropped, or otherwise damaged in any way. If the inverter/charger is damaged, read the warranty section. 7. Do not disassemble the inverter/charger. It contains no user-serviceable parts. See warranty for instructions on obtaining service. Attempting to service the inverter/charger yourself may result in a risk of electrical shock or fire. Internal capacitors remain charged after all power is disconnected. 8. The inverter contains more than one live circuit (batteries and AC line). Power may be present at more than one source. To reduce the risk of electric shock, disconnect both AC and DC power from inverter/charger before attempting any maintenance or cleaning or working on any circuits connected to the inverter/charger. Turning off controls will not reduce this risk. 9. Use insulated tools to reduce the chance of short-circuits when installing or working with the inverter or the batteries. Precautions When Working with Batteries 1. Make sure the batteries are well ventilated. Avoid blocking enclosure vents. 2. Never smoke or allow a spark or flame near the inverter or batteries. 3. Use caution to reduce the risk of dropping a metal tool on the batteries. It could spark or short circuit the battery or other electrical parts and could cause an explosion. 4. Remove all metal items, like rings, bracelets, and watches when working with lead-acid batteries. Lead-acid batteries produce a short circuit current high enough to weld metal to skin. 5. Make sure someone is close enough to aid should anything dangerous occur when you re working near a lead-acid battery.
4 6. Prepare enough fresh water and soap in case battery acid contacts skin, clothing or eyes. 7. Wear complete eye protection and clothing protection. Avoid touching your eyes while working near batteries. 8. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters your eyes, immediately flood in cold water and get medical attention immediately. 9. If you need to remove a battery, always remove the ground terminal from the battery first. Make sure all accessories are off so you don t cause a spark. 10. Always use identical types of batteries. 11. Never install old or untested batteries. Check each battery s date code label to ensure age and type. 12. Batteries are temperature sensitive. For optimal performance, they should be installed in a stable temperature environment. 13. Always recycle old batteries. Contact your local recycling center for proper disposal information. General Information Thank you for purchasing the APS inverter series. The inverter is a combination of an inverter, charger. It is packed with unique features and it is one of the most advanced inverter/charger in the market today. The inverter features an AC bypass circuit, powering your gate operators and access controls or any appliance from the utility power or generator power while charging the battery. When utility power fails, the battery backup system keeps your equipment powered until utility power is restored. Internal protection circuits prevent overdischarging the batteries by shutting down inverter when a low battery condition occurs. When utility or generator power is restored, the inverter transfer to the AC source and recharges the batteries. The series inverter can also serve as a central hub of renewable energy system. Set the series inverter to battery priority mode to designate it to inverter-preferred UPS configuration. In this configuration, the load power is normally provided by the inverter, However, if the inverter output is interrupted, an internal transfer switch automatically transfers the load from the inverter to commercial utility power. The transfer time between inverter and line is short(6ms typically), and such transfers are normally not detected by even highly sensitive loads. Upon restoration of battery capacity, the inverter will transfer back to inverter power (battery). In the line priority mode, when utility power cuts off (or drops below acceptable range), the transfer relay is de-energized and the load is automatically transferred to inverter output. Once the qualified utility power is restored, the relay is energized and the load is automatically reconnected to utility power. It features power factor, sophisticated multi-stage charging and pure sine wave output with unprecedentedly high surge capability to meet demanding power needs of inductive loads without endangering the equipment. The inverter is equipped with a powerful charger of up to 70Amp (depending on mode). The overload capacity is 125~150% of continuous output for up to 20 seconds to reliably support tools and equipment longer. Another important feature is that the inverter can be easily customized to solar priority by DIP switch, this helps to extract maximum power from solar in renewable energy systems. To get the most out of the power inverter, it must be installed, used and maintain properly. Please read the instructions in the manual before installing.
5 Gate operators, access control devices and accessories. Power tools-circular saws, drills, grinders, sanders, buffers, weed and hedge trimmers, air compressors. Office equipment such as computers, printers, monitors, facsimile machines, scanners. Household items, vacuum cleaners, fans, fluorescent and incandescent lights, shavers, sewing machines. Kitchen appliances-coffe makers, blenders, ice makers, toasters. Industrial equipment-metal halide lamp, high-pressure sodium lamp. Home entertainment electronics-television, VCRs, video gate consoles, stereos, musical instruments, satellite equipment. Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Pure sine wave output AC/Battery priority Via function DIP switch Auto generator start. For gate operators Auto open relay. Max. AC charge current 35A Built-in pure copper transformer Low battery trip voltage 10.5V/11.0V setting Auto sense 50HZ/60HZ The following illustration shows basic application for this inverter. It also includes following devices to have a complete running system: Generator or Utility. Battery Also Gate Operators and accessories. APS includes two 35Ahr batteries APS includes two 50Ahr batteries
6 Charge Current Adjuster:25%,50%,75%,100%. Battery Type Selector
7 ON(Power Saver) INVERTER OFF ON IMPORTANT: When the inverter is used to power Gate Operators, switch must be in the ON position. Not the ON (Power Saver) position. Connectors 8, 9 and 10 are extended to the inverter front panel for easy wiring.
8 Before installation, please inspect the unit. Be sure that nothing inside is damaged. You should see the following items inside the main enclosure of the APS series inverters: Ÿ Ÿ Ÿ Main inverter Unit Two Batteries 35Ahr for APS Ahr for APS Battery breaker on the left side inside enclosure Ÿ AC Input/Output and relay connector on inverter front panel Mounting the unit Consider the following before selecting where to install the unit: Ÿ Do not install the inverter on flammable construction materials. Ÿ Mount on a solid surface. Ÿ Install the inverter at eye level in order to read the LCD display clearly. Ÿ For proper air circulation to dissipate heat, leave at least 3 gap above, below and sides of the inverter enclosure. Ÿ The ambient temperature should be between 0ºF and 105ºF to ensure optimal operation. Ÿ The recommended installation position is to be against the wall horizontally. SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY. Install the unit using 4 screws on four mounting holes Mounting holes Mounting holes behind packaging foam
9 Battery Connection CAUTION: For safety and regulation compliance, it s requested to install a separate DC over-current protector between battery and inverter. DO NOT bypass the over-current breaker that s installed between inverter and batteries. Doing so, will increase the risk of fire and possible harm to persons. DC Wiring Recommendation It is recommended the battery bank be kept as close as possible to the inverter. the following is the recommended wiring options for 3 feet long cable. APS series inverters use 4AWG cable that meet or exceed this requirement. If there is a need to replace the battery cables, you must use the proper size to handle the power. If Batteries need to be moved outside the inverter enclosure and need to extend the cable, also increase the wire gauge thickness. 1000W 0-3 feet 2000W 0-3 feet Over-Current Breaker Two Batteries 4AWG BATTERY CABLE One cable is always best, but cable is just copper and copper is what s required, so it does not matter if you use one cable or 10 cables as long as the square are adds up. Performance of any product will be improved by thicker cable and shorter runs, so it is recommended to keep the cables as short as possible.
10 Please follow steps below in case battery cables need to be replaced: 1. Install battery ring terminals on recommended cable and terminal size. 2. Connect battery pack as unit requires. APS must have batteries connected in parallel, and the APS in series. NOTE: Please only use Sealed Lead Acid or Sealed GEL/AGM Lead-Acid Batteries. 3. Connect ring terminals of battery cable into inverter battery connector and make sure bolts are tightened. Make sure polarity is correct at both ends of the cable (battery terminals and inverter connectors) and that ring terminals are tightly screwed to battery terminals. + PARALLEL 12V 35Ahr + 12V V 35Ahr APS Main battery bank, 12VDC. (35Ahr included) wired in parallel SERIES 24V V 12V 50Ahr 50Ahr APS Main battery bank, 24VDC. (50Ahr included) wired in series.
11 AC Input/Output Connection Caution!! Before connecting AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be safely disconnected during maintenance and fully protected from over current of AC input. The recommended AC breaker is 30A for both APS and APS models. Caution!! Please don t connect the output AC to Grid terminals nor connect the grid to the Load terminals. Doing so will permanently damage inverter. WARNING! All wiring must be performed by a qualify person. WARNING! It s very important for system safety and efficiency operation to use appropriate cable for Grid connection. To reduce risk of injury, please use the recommended proper cable size as below. AC Wiring We recommend using 12AWG wire to the AC terminal block. If the inverter is installed farther than 70 feet from main power source, wire gauge must be sized properly to avoid big voltage drops. Be sure all wiring is UL compliant, call our tech support if you are not sure how to wire any part of the inverter. WARNING! It s very important to do the wiring correctly on battery terminals and high voltage AC side. APS APS RLY 2 N.O. COMMON RLY 1 N.O. COMMON 120V AC 60Hz 1000W L N N L INPUT OUTPUT AC Wiring (120VAC, Single phase, 60Hz) Input: Groung +Hot line +Neutral (Main Source) Output: Neutral +Hot line +Ground (Load)
12 Please follow these steps to connect inverter to Load/Grid: 1. Before making Load/Grid connection, be sure to open DC protector/breaker first. 2. Strip each individual wire/conductor about 3/8. 3. Connect grid wires according to polarity indicated on terminal block and tighten the terminal screws. Be sure to connect protective earth conductor ( ) first. -> Ground (green) L-> LINE (black) N-> Neutral (white) RLY 2 N.O. COMMON RLY 1 N.O. COMMON 120V AC 60Hz 1000W L N N L INPUT OUTPUT 4. Then, connect Load (output) wires according to polarity indicated on terminal block and tighten terminal screws. Be sure to connect protective earth conductor ( ) first. -> Ground (green) L-> LINE (black) N-> Neutral (white) RLY 2 N.O. COMMON RLY 1 N.O. COMMON 120V AC 60Hz 1000W L N N L INPUT OUTPUT 5. Make sure all wires are securely connected. AC output (load) CAUTION: Appliances such as air conditioner require at least 2~3 minutes to restart to have enough time to balance refrigerant gas inside of circuits. If a power outage occurs and recovers in a short time, it will cause damage to your connected appliance. To prevent this kind of damage, please check manufacturer of air conditioner if it s equipped with time-delay function before installation. Otherwise, this inverter will trigger overload fault and cut off output to protect your appliance but it is still possible it will cause internal damage to the air conditioner.
13 APS APS Vac 75Vac 2% 80Vac 2% 140Vac 2% 135Vac 2% 140Vrms Same as Input Waveform 30A 40A
14 APS APS VAC 2,000VA Instant Reverse Gate Motors Two 1/2 HP or One 1HP 4,000VA Instant Reverse Gate Motors Four 1/2 HP or Two 1HP 11V 22V 11Vdc ± 0.3Vdc 22Vdc ± 0.6Vdc 10.5Vdc ± 0.3Vdc 21Vdc ± 0.6Vdc 16Vdc ± 0.3Vdc 32Vdc ± 0.6Vdc 15.5Vdc ± 0.3Vdc 31Vdc ± 0.6Vdc
15 APS Vac Vac APS A Vdc 21V-31.4Vdc 15.7Vdc 31.4Vdc Alarm beeps 0.5s second & Fault after 60s
16
17 Auto generator start (AGS) There is an extra connector in front of the inverter (Relay 2) used to start a generator or to trigger a gate operator to open the gate before battery runs out of power. If the utility power is abnormal and single battery discharges below 11VDC, the inverter will send out a signal to either a generator start circuit or to a gate operator to trigger the gate to open. Once the battery is charged to 13.5VDC or higher, the signal will deactivate and switch to normal operation. Auto AC power off signal Includes a relay N.O. contact used to trigger a gate operator to open the gate on AC utility power failure. Once AC utility power fails, the relay will trigger the signal. Relay Function for gate operators: RELAY 1: Activates immediately after a power outage. I can be to trigger a gate operator to open the gate. One time open. It will stay active until power is restored. RELAY 2: Activates after a power failure and battery voltage has reached the low level threshold. It could be used to trigger a gate operator to open before battery is fully depleted. Using this relay to trigger a gate to open, will allow a gate operator to run on battery backup but will ensure gate opens before battery fails. For Failsafe connect to gate operator OPEN CMD For Failsecure connect to gate operator CLOSE_CMD RLY 2 N.O. COMMON RLY 1 N.O. COMMON 120V AC 60Hz 1000W L N N L INPUT OUTPUT
18 *2 for APS VAC VAC VAC SW3 Power saver auto setting check load every 5s check load every 30s SW5 Battery/AC priority setting Utility priority Battery priority For APS , the low battery trip volt is set at 11.0VDC for sealed lead acid battery. It can be changed to 10.5VDC using Sw1 for deep cycle lead acid battery, this is to prevent batteries from over-discharging while there is only a small load applied on the inverter. (*2 for APS ) There are different acceptable AC voltage input ranges for different kinds of loads. For some relatively sensitive electronic devices, a narrow input range of VAC is required to protect them. While for some resistive loads which work in a wide voltage range, the input AC range can be customized to VAC, this helps to power loads with the most AC input power without switching to battery bank. For gate operators we use the setting VAC By default the inverter is set to detect the load for 250ms every 5 seconds. This cycle can be customized to 30 seconds through the Sw3 DIP switch. Note: Power saver mode should not be used when using inverter for a gate operator. Set the inverter frequency while in battery mode. The inverter is designed with AC priority by default. This means, when AC input is present, the battery will be charged first, and the inverter will transfer the input AC to power the load. Only when AC input is stable for a continuous period of 15 days, the inverter will start a battery inverting cycle to protect the battery. After 1 cycle normal charging and AC will be restored and go back to bypass mode.
19 The AC priority and battery priority switch is SW5. When switch is set to battery priority, the inverter will run on battery power even if AC input is present. Only when the battery voltage reaches the low voltage threshold (11.5V for 12V & 23V for 24V). The inverter transfers to AC input, charges battery, and switches back to battery when it is fully charged. This function is mainly for wind/solar applications and utility power is strictly backup. But it could also be useful in locations where a lot of brow-outs happen. Battery voltage restart After low battery voltage shut off (10.5V for 12V model / 20V for 24V model), the inverter is able to restore operation after the battery recovers to 13V for 12V model and 26V for 24V model (with power switch still in the ON position). This function helps to save the users extra work reactivating the inverter when the low battery voltage returns to an acceptable range in the renewable energy systems. the built in battery charger will automatically reactivate as soon as utility/generator ac has been stable for 15 seconds. USA AGM 1 AGM 2 EURO Open lead acid 7 Calcium De sulphation APS /APS Low trip to AC model 11.5V/23V 14V/28V 14.1V/28.2V 14.6V/29.2V 14.4V/28.8V 14.4V/28.8V 14.8V/29.6V 15.1V/30.2V 15.5V/31V APS /APS V/28V 13.4V/27.4V 13.4V/26.8V 13.7V/27.4V 13.6V/27.2V 13.8V/27.6V 13.3V/26.6V 13.6V/27.2V 4 hours then off Note: APS series inverter include Sealed Lead Acid Batteries. If different chemistry batteries are used, this setting must be adjusted to match the charging voltage appropriate for the type of battery.
20 By restarting the inverter. Turn it OFF and back ON.
21 Indicators on display panel Note: = indicator ON. x = indicator OFF., blink shows the indicator blinking about 0.5s on and 0.5s off.
22 APS series inverter Battery discharged main no output voltage not charging fan stopped running charger fault/battery connection fault too many devices connected connected motor s current draw exceeds inverter power There isn t enough ventilation to cool the inverter. inverter overload charger fault/charger battery select switch in wrong battery setting power switch in wrong position wire connections are incorrect inverter is damaged inverter battery selector in wrong setting wire connections are incorrect inverter is not in AC mains mode panel switch is on power saver ON check charger, and check and make sure battery connection is correct motor current draw at start is huge, 3-4 times. you need inverter with higher wattage keep batteries separated from eachother set the battery select switch to correct battery setting set power switch to power ON (down position) select the correct battery chemistry turn ON AC mains to switch to AC mode turn panel switch to power ON (down position) check if something is blocking the fan Open the inverter and find a white prove cable (on cooling fan). Keep it at short-circuit, the fan should run. If not, then there s a problem with the fan. Check inside inverter Note: APS and APS inverter s fan starts to run when temperatures reach º F
23
24 POWER INVERTER
PureWatts Elite Power Inverter. Instruction Manual 1000 / 2000 WATTS
PureWatts Elite Power Inverter Instruction Manual 1000 / 2000 WATTS www.sinergex.com 1 CONTENTS Introduction 3 Important Safety Information 3 Features & Applications 4 Electrical Performance 5 Mechanical
More informationSA-1000K & SA-3000K Series Pure Sine Wave Inverter User s Manual
SA-1000K & SA-3000K Series Pure Sine Wave Inverter User s Manual Table of Contents 1. Important Safety Information. 1 1-1 General Safety Precautions 1 1-2 Battery Precautions.... 1 2. Features... 2 2-1
More informationS600,S600R Series Pure Sine Wave Inverter User s Manual
S600,S600R Series Pure Sine Wave Inverter User s Manual Table of contents 1. Important Safety Information. 1 1-1 General Safety Precautions 1 1-2 Batteries Precautions.. 1 2. Features... 2 2-1 Applications..
More informationDon't let the shadows of yesterday hide the sunshine of tomorrow Nandina Morris
Don't let the shadows of yesterday hide the sunshine of tomorrow. -------------- Nandina Morris Hybrid MPPT Solar Inverter Main Features Pure sine wave inverter Built-in MPPT solar charge controller Selectable
More informationCS+ Series. Pure Sine Wave Inverter/Charger User s Manual. Version 1.0 DIF
CS+ Series Pure Sine Wave Inverter/Charger User s Manual Version 1.0 DIF The CS+DIF range of Inverter /Chargers are powerful, robust and professional. It includes in one unit three functions : a powerful
More informationS600,S600R Series Pure Sine Wave Inverter User s Manual
S600,S600R Series Pure Sine Wave Inverter User s Manual List of contents 1. Important Safety Instructions 1 1-1 General Safety Precautions 1 1-2 Precautions When Working With Batteries.. 1 2. Features...
More informationPure Sine Wave DC TO AC Power Inverter. User s Manual
Pure Sine Wave DC TO AC Power Inverter User s Manual Distributed by: Tech Brands by Electus Distribution 320 Victoria Road, Rydalmere NSW Australia Tel: 1300 738 555 Fax: 1300 738 500 www.techbrands.com
More informationPureSine 150/300 Pure Sine Wave Inverter User s Manual
PureSine 150/300 Pure Sine Wave Inverter User s Manual 1. Important Safety Instructions WARNING! Before you install and use your Inverter, please read and follow these safety instructions. 1-1. General
More informationPure Sine Wave Inverter Charger
Pure Sine Wave Inverter Charger Renogy 1000W 2000W Pure Sine Wave Inverter Charger Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 Version 1.6 1 Important Safety Instructions Please save
More informationUser Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER
User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture... 2 Product Overview...
More informationMASTERsine Inverter PXA Series Installation Guide
Backup Power System Expert TM MASTERsine Inverter PXA Series Installation Guide Important Safety Instructions IMPORTANT: Read and save this Installation Guide for future reference. This chapter contains
More informationUser manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger
User manual Solar Hybrid 1-5KVA Uninterruptible Power Supply / Charger All rights reserved. The information in this document is subject to change without notice. Thank you for purchasing this series UPS.
More informationUser Manual 1KVA-5KVA INVERTER / CHARGER
User Manual 1KVA-5KVA INVERTER / CHARGER Version: 1.7 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationS600,S600R Series Pure Sine Wave Inverter User s Manual
S600,S600R Series Pure Sine Wave Inverter User s Manual Table of contents 1. Important Safety Information.... 1 1-1 General Safety Precautions...... 1 1-2 Batteries Precautions... 1 2. Features... 2 2-1
More informationMPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4
User Manual 800W-4000W Hybrid solar inverter Version: 1.4 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationSolar Hybrid Inverter SP Efecto Series
User Manual Solar Hybrid Inverter SP Efecto Series Version 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationGeneral Precautions. Personnel Precautions
USER MANUAL General Precautions 1. Before using Inverex, read all instructions and cautionary markings on : (1) Inverex (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only
More informationUser Manual 1KVA-5KVA INVERTER / CHARGER
User Manual 1KVA-5KVA INVERTER / CHARGER Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture... 2 Product
More informationUser Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER
User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER WWW.POWERHIGHWAY.NET CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS...... 1 INTRODUCTION... 2 Features... 2 Basic System
More informationS150,S300 Series Pure Sine Wave Inverter User s Manual
S150,S300 Series Pure Sine Wave Inverter User s Manual List of contents 1. Important Safety Instructions 3 1-1 General Safety Precautions 3 1-2 Precautions When Working With Batteries.. 3 2. Features...
More informationSOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan
SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA Appliances 420-00300-02 PC TV Light Electricfan Table Of Contents GENERAL PRECAUTIONS... 1 PERSONNEL PRECAUTIONS... 1 INTRODUCTION...
More informationUser Manual & Installation Instructions
12KW Inverter Charger Residential & Commercial User Manual & Installation Instructions Model SEI 12 Off Grid + On Grid + AC Charger + MPPT + AGS +ATS + UPS 1-1. General Safety Precautions 1. Before installing
More informationAP Series Pure Sine Wave Inverter/Charger User s Manual. Version 1.0
AP Series Pure Sine Wave Inverter/Charger User s Manual Version 1.0 Composer: Franklin Chu Date: Feb 12 th, 2012 1 Table of Contents 1. Important Safety Information... 3 1-1. General Safety Precautions...
More informationUser Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller
User Manual 4KVA/ 5KVA INVERTER / CHARGER With MPPT Controller CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationUser Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1
User Manual 1.5KVA-3KVA INVERTER / CHARGER Version: 1.1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationUser Manual 1.5KVA-3KVA INVERTER / CHARGER
User Manual 1.5KVA-3KVA INVERTER / CHARGER Version: 1.0 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationSolar Hybrid Inverter SP Efecto Series
User Manual Solar Hybrid Inverter SP Efecto Series Version 1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationST Series. Pure Sine Wave Power Inverter User s Manual
ST Series Pure Sine Wave Power Inverter User s Manual Contents 1. Important Safety Instructions. 2 1-1 General safety precautions 2 1-2 Precautions when working with Batteries 2 2. Functional Characteristics..
More informationUSER MANUAL. GS Series Hybrid Inverter
USER MANUAL GS Series Hybrid Inverter CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 IMPORTANT SAFETY INSTRUCTIONS... 1 General Precautions... 1 Personal Precautions... 2 INSTALLATION... 3 Unpacking
More information1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3
1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER User Manual Version: 2.3 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features...
More informationSolar Hybrid Inverter SP Brilliant Series
User Manual Solar Hybrid Inverter SP Brilliant Series Version: 1.5 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System
More informationUser Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3
User Manual 5KVA/5KW INVERTER / CHARGER Version: 1.3 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationST Series Pure Sine Wave Power Inverter User s Manual
ST Series Pure Sine Wave Power Inverter User s Manual 正式文件 妥善保存 Contents 1. Important Safety Instructions. 2 1-1 General safety precautions 2 1-2 Precautions when working with Batteries 2 2. Functional
More informationUSER MANUAL. PW Series Inverter / Charger
USER MANUAL PW Series Inverter / Charger CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 IMPORTANT SAFETY INSTRUCTIONS... 1 General Precautions... 1 Personal Precautions... 2 INSTALLATION... 3
More informationUser Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0
User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER Version: 1.0 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationAUTO CHARGE D PUMP PLUS
INSTRUCTION MANUAL AUTO CHARGE D PUMP PLUS AUTOMATIC DUAL OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-9-DPP INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY:
More information400 Watt Backup Power System Owner s Manual
400 Watt Backup Power System Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
More informationTable of Contents 文管中心 發行章
ST600-XXX Series Pure Sine Wave Power Inverter User s Manual Table of Contents 1. Important Safety Instructions 1-1 General Safety Precautions 1 1-2 Battery Precautions. 1 2. Basic Descriptions 2-1 Mechanical
More informationUser Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1
User Manual 1KVA-5KVA INVERTER / CHARGER Version: 2.1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationDC TO AC POWER INVERTER
DC TO AC POWER INVERTER 12V / 24V / 48Vdc Input 115V / 230Vac Output 150W ~ 6000W Output cont. L-Series User Manual Before install and use your Inverter, read the User Manual and safety instructions. Cooler
More informationOPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS
ASSOCIATED OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS MODEL 6366 12 VOLT, 0-20 AMP 4 X 20 BATTERY CHARGER 1. SAVE THESE INSTRUCTIONS. This manual contains important safety and operating instructions
More informationGlobal LF Series Pure Sine Wave Inverter Charger User s Manual PICOGLF12W12V120AL & PICOGLF25W12V120AL
Global LF Series Pure Sine Wave Inverter Charger User s Manual PICOGLF12W12V120AL & PICOGLF25W12V120AL Table of Contents... - 1-1. Important Safety Information... - 2-1-1. General Safety Precautions...
More informationSolar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-
Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva With integrated star point grounding* according to VDE AR-E 2510- and power factor 1.0 AX-M series: Part numbers: 4000 VA 5000
More informationAUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL
INSTRUCTION MANUAL AUTO CHARGE D2 AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-74-12 INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY 1
More informationUser Manual. Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5
More informationSOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine
SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA Appliances 420-00288-01 PC TV Airconditioning Fridge Washing machine Table Of Contents ABOUT THIS MANUAL...1 Purpose... 1 Scope... 1 SAFETY
More informationDC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL
DC TO AC PURE SINE POWER INVERTER PWRI18012S INSTRUCTION MANUAL 1 A. INTRODUCTION The AIMS Power pure sine inverter product line is used for back-up power. The pure sine product line is ideal for sensitive
More informationBATTERY SAVER LOW RIPPLE HO
INSTRUCTION MANUAL BATTERY SAVER LOW RIPPLE HO LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS MODEL #: 091-195-12 INPUT: 120 Volt, 50/60 Hz, 4.5 Amps RMS OUTPUT: 13.2 Volts DC,
More informationBattery Power Inverters
Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.4 Important Safety Instructions Please save these instructions.
More informationGlobal LF Series Pure Sine Wave Inverter/ Charger User s Manual
Global LF Series Pure Sine Wave Inverter/ Charger User s Manual For PICOGLF6W12V120VR 1 Table of Contents 1.1 General Safety Precautions... 3 1.2 Precautions When Working with Batteries... 3 2.1 General
More informationCompact Sine Inverter
Compact Sine Inverter Instructions for installation & use Applies to the following models: Output power: 700watt, 1000 watt, 1500watt, 2000 watt & 3000 watts Output voltage: and output, 50Hz & 60Hz Output
More informationAlphapower HTU UPS. Some key features include:
The is a durable, high operating temperature UPS, ideal for outdoor applications. It is a combination of an inverter, battery charger and AC transfer switch in one complete system with a peak conversion
More informationAUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL
INSTRUCTION MANUAL AUTO CHARGE 4000 LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER Unit supplied with this display MODEL #: 091-89-12 INPUT: 120 Volt, 50/60 Hz, 5 Amps OUTPUT: 45 Amps File:
More informationLINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL
LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL Important Safety Information Before installing UPS EN-1000/ EN-2000, please read the operating instructions carefully. Special attention
More informationGlobal LF Series Pure Sine Wave Inverter Charger User s Manual. Version 2.0 PICOGLF10KW48V240VS
Global LF Series Pure Sine Wave Inverter Charger User s Manual Version 2.0 PICOGLF10KW48V240VS Table of Contents 1. Important Safety Information... - 3-1.1 General Safety Precautions... - 3-1.2 Precautions
More informationGlobal LF Series Pure Sine Wave Inverter/AC Charger User s Manual. Version 7.0
Global LF Series Pure Sine Wave Inverter/AC Charger User s Manual Version 7.0 Table of Contents 1. Important Safety Information... - 2-1-1. General Safety Precautions... - 2-1-2. Precautions When Working
More informationMINI/ PSW7 Series. Pure Sine Wave Inverter/Charger User s Manual. Version 1.0. Your Best Partner for Power
MINI/ PSW7 Series Pure Sine Wave Inverter/Charger User s Manual Version 1.0 Contact information email: sales@foxpowerups.com Website: www.foxpowerups.com Table of Contents 1. Important Safety Information
More informationPure Sine Wave Inverter User Manual
48-3000RM 2U 19, 2 Post Rack Mount & 4 Post Open Frame Cabinet Mount Pure Sine Wave Inverter User Manual Newmar PO Box 1306 Newport Beach, CA 92663 www.poweringthenetwork.com Tel: 714-751-0488 M-483000RM
More informationAC CONVERTER / BATTERY CHARGER
AC CONVERTER / BATTERY CHARGER User s Manual MODEL #: CON120AC12/24VDC Listed to UL 458 and CSA 22.2 NO. 107.1 Standards Contents INTRODUCTION... 3 Important Safety Instructions... 3 1. General Description...
More informationLESTRONIC II BATTERY CHARGER MODEL 07210
LESTRONIC II BATTERY CHARGER MODEL 07210 PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment, it is important to read and be familiar with this entire manual
More information1000 Watt Pure Sine Wave Power Inverter, Users Manual
WF-5100 Series 1000 Watt Pure Sine Wave Power Inverter, Users Manual Distributed in the USA and Canada by Arterra Distribution 2021 Aeroplex Drive North. Elkhart, IN. 46514 Phone: 877-294-8997, Fax: 547-294-8698
More informationAUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:
INSTRUCTION MANUAL AUTO CHARGE DUAL AUTOMATIC DUAL OUTPUT BATTERY CHARGER MODEL #: 091-145-12 INPUT: 120 Volt, 50/60 Hz, 3.5 Amps OUTPUT BAT 1: 10 Amps OUTPUT BAT 2: 10 Amps File: IM_091-145-12_revb.indd
More informationPure Sine Wave Inverter GP-HS1500. Owner s Manual
Pure Sine Wave Inverter GP-HS1500 Owner s Manual 2 Table of Contents Introduction 3 Specifications 4 Name and Main Function 5 Installation 7 Operation 9 Operating Limits 13 Troubleshooting 13 Maintenance
More informationAUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:
INSTRUCTION MANUAL AUTO CHARGE 4000 AUTOMATIC DUAL OUTPUT BATTERY CHARGER MODEL #: 091-89-12 INPUT: 120 Volt, 50/60 Hz, 8 Amps OUTPUT BATTERY CHARGER: 40 Amps OUTPUT BATTERY SAVER: 5 Amps File: IM_091-89-12_reve.indd
More informationCruising Charger Series OWNER S MANUAL
R Cruising Charger Series OWNER S MANUAL ON BOARD BATTERY CHARGERS Models DC Amperage No. Of Banks Volts 2614A 5,10 Amps 2 Bank 12/12 2614A-230 2621A 5,5,10 Amps 3 Banks 12/12/12 2621A-230 2622A 10,10
More informationBATTERY CHARGER CHR-1445
BATTERY CHARGER CHR-1445 / 2685 TEL:886-4-2238-0698 FAX:886-4-2238-0891 Web Site:http://www.monicon.com.tw E-mail:sales@monicon.com.tw Copyright 2007 Monicon Instruments Co., Ltd. All right reserved. Contents
More informationGlobal LF Series Pure Sine Wave Inverter Charger User s Manual
Global LF Series Pure Sine Wave Inverter Charger User s Manual Version 2.0 PICOGLF4KW & 6KW ETL Certified to UL 1741 & CSA STDC 22.2 NO. 107.1 Table of Contents 1. Important Safety Information... - 3-1.1
More informationIPS3000P 3KVA INVERTER / CHARGER. Version 1.00 (English) BEFORE GETTING STARTED
IPS3000P 3KVA INVERTER / CHARGER Version 1.00 (English) BEFORE GETTING STARTED This document is designed to aid you to get started with the device. If you experience problems following these guides or
More informationPure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A
Pure Sine Wave Power Inverter SSW-350-12A SSW-600-12A SSW-1000-12A SSW-1500-12A SSW-2000-12A Owner's Manual Please read this manual before installing your inverter 1 IMPORTANT SAFETY INSTRUCTIONS THIS
More informationTXF Series. Pure Sine Wave Inverter/AC Charger User s Manual. Version 1.0. TorTech. Designed to ISO9001 manufacturing standard
TXF Series Pure Sine Wave Inverter/AC Charger User s Manual Version 1.0 TorTech Designed to ISO9001 manufacturing standard Total Transformer Solutions Australia s Transformer Specialist for 25 Years Tel:
More informationGP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:
Go Power! Manual GP-1000 Inverter Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: 866-247-6527 Fax: 866-607-6527 Email: info@gpelectric.com Table of Contents 1. INTRODUCTION 3 2. SPECIFICATIONS
More information12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer
12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer For lead-acid batteries THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR 12V BATTERY CHARGER: YUA1201000 / INT1201000 KEEP
More informationSolar Inverter Manual
Solar Inverter Manual Introduction SMPS series solar inverter power charging efficiency increased by 30%~60% than traditional controller charging. This inverter has automatic identification, three-stage
More informationSentry Battery Charger. Installation and Operations Manual Section 75
Sentry Battery Charger Installation and Operations Manual 00-02-0616 03-03-08 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our
More informationGlobal LF Series Pure Sine Wave Inverter/ Chargers 5-12KW User s Manual. Version 4.0 (Code: / Updated on NOV 14 th 2013)
Global LF Series Pure Sine Wave Inverter/ Chargers 5-12KW User s Manual Version 4.0 (Code: 614-01208-00 / Updated on NOV 14 th 2013) 1 Table of Contents 1. Important Safety Information... 3 1-1. General
More informationSolar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C
Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5
More informationDC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual
DC AC POWER INVERTER LIV 10 / LIV 20 / LIV 30 User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the Power Inverter. This
More informationPUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL
INSTRUCTION MANUAL PUMP PLUS 2000 PLC AUTOMATIC DUAL OUTPUT BATTERY CHARGER Supplied with Dual Bar Graph Display MODEL #: 091-237-12-PP INPUT: 120 Volt, 60 Hz, 3.5 Amps OUTPUT BATTERY 1 and 2: 15 or 18
More informationPI1500X Power Inverter User s Manual
PI1500X Power Inverter User s Manual featuring WARNING Failure to follow instructions may cause damage or explosion, always shield eyes. Read entire instruction manual before use. Warning: This product
More informationGSL Electronics Modified Sine Wave Power Inverters
GSL Electronics Modified Sine Wave Power Inverters Congratulations on choosing one of our Modified Sine Wave Inverters for your application. There are 6 models in the range, which will meet most of your
More informationAUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL
INSTRUCTION MANUAL AUTO CHARGE 12 HO AUTOMATIC SINGLE OUTPUT BATTERY CHARGER MODEL #: 091-170-6 MODEL #: 091-170-12 MODEL #: 091-170-24 File: IM_091-170-xx_revd.indd Rev: D Revised By: MFG Date: 10-23-2013
More informationUser Manual 200Ah INVERTER / CHARGER
User Manual 200Ah INVERTER / CHARGER TABLE OF CONTENT 1. ABOUT MANUAL... 1 2. SAFETY INSTRUCTION... 1 3. INTRODUCTION... 2 3.1 FEATURES... 2 3.2 PRODUCT OVERVIEW... 2 4. INSTALLATION... 3 4.1 UNPACKING
More informationArt. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2
SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...
More informationDeltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord
Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System Designed for Six-cell and three-cell Flooded/AGM/GEL Lead-Acid Batteries and Four-Cell Lithium Iron Phosphate (LiFePO4) Batteries
More informationUSER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA
USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA Important Safety Information Before installing UPS Endure 500VA/750VA/1000VA/2000VA, please read the operating instructions carefully.
More informationInverter User Manual
Inverter User Manual -------------for standard model DC TO AC Power Inverter CONTENTS Safety First 1. Introduction 2. Installation Guidelines 3. Using the inverter 4. Troubleshooting 5. Specifications
More informationLow Frequency Inverter. User Manual
Pure Sine Wave 220-240V 50-60Hz Low Frequency Inverter User Manual For LK/LW series Power Star inverters only, models: LK2000, LK2000-24, LK3000, LK3000-24, LK3000-48, LK6000-24, LK6000-48 1. Safety precautions
More informationPSJ-2212, PSJ-3612, PSJ-4424
Model: PSJ-2212, PSJ-3612, PSJ-4424 Jump Starter and DC Power Source OWNER S MANUAL PSJ-2212 PLEASE SAVE THIS OWNER S MANUAL AND READ BEFORE EACH USE. This manual will explain how to use your jump starter
More informationFlinSlim Lite Solar Hybrid Inverter 1KVA-5KVA USER MANUAL. Version: 1.3
1KVA-5KVA USER MANUAL Version: 1.3 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture... 2 Product Overview...
More informationMODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE
MODEL A96 SERIES 130Vdc Switchmode Utility Rectifier / Battery Charger Used with LaMarche Power Cage CPN112138 ECN/DATE ISSUE DATE: ECN 17010-12/05 106 BRADROCK DRIVE DES PLAINES, IL. 60018-1967 (847)
More informationSCC-MPPT Solar Charge Controller
Solar Charge Controller Quick Guide 200W 300W 400W 600W 850W V. 2.2 1. Introduction solar charge controller uses PWM-based DSP controller to keep the batteries regulated and prevent batteries from overcharging
More informationUser Manual LV 3KVA-24V INVERTER / CHARGER. Version: 1.1
User Manual LV 3KVA-24V INVERTER / CHARGER Version: 1.1 Table of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More informationUser Manual 3KVA-5KVA INVERTER / CHARGER. Version: 1.1
User Manual 3KVA-5KVA INVERTER / CHARGER Version: 1.1 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture...
More information1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY
1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY CONTENTS Warranty 2 Introduction 3 Environmental protection 3 Specifications 3 General safety warnings and instructions 4 Important safety instructions
More informationLPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL
INSTRUCTION MANUAL LPC 20 LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-207-12 INPUT: 120 Volt, 50/60 Hz, 7 Amps OUTPUT: 20 Amps File:
More informationAUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL
INSTRUCTION MANUAL AUTO CHARGE 11 AUTOMATIC BATTERY CHARGER U.L. Configuration MODEL #: 091-11-XX NOTE : This charger is designed for vehicles with dual batteries and negative ground. CAUTION This unit
More informationUser Manual / Manuel utilisateur
User Manual / Manuel utilisateur Inverter Charger / Convertisseur Chargeur English version...1 English Version 1 Table of Contents ABOUT THIS MANUAL... 3 Purpose... 3 Scope... 3 SAFETY INSTRUCTIONS...
More information24 VOLT AUTOMATIC BATTERY CHARGER PART NO
24 VOLT AUTOMATIC BATTERY CHARGER PART NO. 957732 AC Input: DC Output: Battery Type: Specifications 230 volts, 50 hertz, 3.5 amps, single-phase 24 volts, 20 amps initially tapering to 6 amps 24 volt, 12
More informationNB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS
NB 0811 - NB 1511 NB 0831 - NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS LEN.MAN.UPS.069 Rev.2.00/2002 CONTENTS Safety Instructions 1 Introduction 3 2.1 FEATURE 3 2.2 UPS modules 4 How the UPS works 5 3.1
More informationPUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL
INSTRUCTION MANUAL PUMP PLUS 1000 PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-215-12-PP INPUT: 120 Volt, 60 Hz, 3.5 Amps OUTPUT BATTERY 1 and 2: 15
More information