LED Emergency Drivers

Size: px
Start display at page:

Download "LED Emergency Drivers"

Transcription

1 LED Emergency Drivers McWong Interna onal, Inc Arena Blvd., Sacramento, CA Tel: Fax: Web: Copyright 2015 McWong Interna onal, Inc. Speci ca ons subject to change without no ce V2.0

2 Table of Contents Product Lis ngs LED Emergency Driver: Linear Case LED Emergency Driver: Rectangular Case...12 LED Emergency Driver: Extra Compact Driverless LED Emergency..24 Addi onal Resources Other Product Lines Limited Warranty

3 How to Order LEM U Input U = Universal VAC Opera ng Current: 0700 = 700mA Max : 026 = 26VDC 028 = 28VDC 056 = 56VDC McWong s LEM series of LED Emergency Drivers is designed to provide emergency backup power for safety compliance to UL 924; CAN/CSA-C22.2 No and NFPA requirements for 90 minute egress. This product replaces emergency uorescent ballasts when xtures are converted from uorescent to LED light sources, or for new LED luminaires. One set of two NiCd ba ery packs Standard Features: Safety compliance to UL 924; CAN/CSA- C22.2 No and NFPA requirements for 90 minute egress Open circuit / short circuit protec on Opera ng temperature: 32 F/0 C to 122F/50 C Test switch / charging indicator light Emergency reac on me 1 sec Powder coat steel, stainless or galvannealed case Standard installa ons require three separate parts to func on: One non-emergency LED driver (AC input) LEM U x BCP-NiCd L 4 One LEM series LED emergency driver *Each LED emergency driver model is assigned a default set of ba ery packs, which are automa cally included with your order. Other ba ery pack One set of two NiCd ba ery packs op ons are available, but must be special ordered. This product series is op mized for use with McWong s LED modules. For ques ons regarding compa bility with light sources from other manufacturers please contact technical support. Field-replaceable NiCd ba ery pack (x2) with Emergency-only installa ons require two separate parts: Min. Lead length: 6 UL1452 solid/18awg quick connect 5 One LEM series LED emergency driver 1000V/90 C 4 LED Emergency Drivers: Linear Case Model No.* Input Power Current Ba ery Wa age & Case Type: 0xx = Linear Case Mxx = Rectangular Case Cxx = Extra Compact Case Dxx = Driverless x07 = 7W x18 = 18W Product Series: LEM = LED Emergency Driver Ba ery Capacity Recharge Time (VAC) (W) (VDC) (ma) (VDC) (Ah) (hr) Default Ba ery Pack* LEM U x BCP-NiCd L LEM U x BCP-NiCd L UL

4 LED Emergency Drivers: Linear Case LED Emergency Drivers: Linear Case Dimensions: LEM U Wiring Diagrams: LEM U LEM Driver LEM U 31 mm 25 mm 337 mm 356 mm Con gura on #1: Shared Load Ba ery Pack BCP-NiCd L Dia. 21 mm 20 mm Con gura on #2: Par al Load 2 mm 270 mm 320 mm Model No. Max Overall Length Width Height Moun ng Centers Min Lead Length Weight 6 77 (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (lbs) LEM U BCP-NiCd L* Con gura on #3: Separate Emergency / AC Loads *The driver and ba ery packs are a matched set, which are automa cally paired together when you order. Other ba ery pack op ons are available, but must be special ordered.

5 LED Emergency Drivers: Linear Case LED Emergency Drivers: Linear Case Dimensions: LEM U Wiring Diagrams: LEM U LEM Driver LEM U 31 mm 25 mm 337 mm 356 mm Con gura on #1: Shared Load Ba ery Pack BCP-NiCd L Dia. 25 mm 21 mm Con gura on #2: Par al Load 2 mm 340 mm 388 mm Model No. Max Overall Length Width Height Moun ng Centers Min Lead Length Weight 8 99 (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (lbs) LEM U BCP-NiCd L* Con gura on #3: Separate Emergency / AC Loads *The driver and ba ery packs are a matched set, which are automa cally paired together when you order. Other ba ery pack op ons are available, but must be special ordered.

6 LED Emergency Drivers: Linear Case LED Emergency Drivers: Linear Case Dimensions: LEM U Wiring Diagrams: LEM U LEM Driver LEM U 31 mm 337 mm 356 mm Con gura on #1: Shared Load 25 mm Ba ery Pack BCP-NiCd L Dia. 25 mm 20 mm Con gura on #2: Par al Load 2 mm 388 mm 440 mm Model No. Max Overall Length Width Height Moun ng Centers Min Lead Length Weight (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (lbs) LEM U BCP-NiCd L* Con gura on #3: Separate Emergency / AC Loads *The driver and ba ery packs are a matched set, which are automa cally paired together when you order. Other ba ery pack op ons are available, but must be special ordered.

7 How to Order LEM - M U Input U = Universal VAC Opera ng Current: 0350 = 350mA Max : 056 = 56VDC LED Emergency Drivers: Rectangular Case Wa age & Case Type: 0xx = Linear Case Mxx = Rectangular Case Cxx = Extra Compact Case Dxx = Driverless x07 = 7W x18 = 18W McWong s LEM series of LED Emergency Drivers is designed to provide emergency backup power for safety compliance to UL 924; CAN/CSA-C22.2 No and NFPA requirements for 90 minute egress. This product replaces emergency uorescent ballasts when xtures are converted from uorescent to LED light sources, or for new LED luminaires. Once set of two NiCd ba ery packs Standard Features: Safety compliance to UL 924; CAN/CSA- C22.2 No and NFPA requirements for 90 minute egress Open circuit / short circuit protec on Opera ng temperature: 32 F/0 C to 122F/50 C Test switch / charging indicator light Emergency reac on me 1 sec Powder coat steel, stainless or galvannealed case 12 Standard installa ons require three separate *Each LED emergency driver model is assigned a default set of ba ery packs, which are automa cally included with your order. Other ba ery pack parts to func on: op ons are available, but must be special ordered. This product series is op mized for use with McWong s LED modules. For ques ons regarding One non-emergency LED driver (AC input) compa bility with light sources from other manufacturers please contact technical support. One LEM series LED emergency driver One set of two NiCd ba ery packs Field-replaceable NiCd ba ery pack (x2) with Emergency-only installa ons require two separate parts: Min. Lead length: 6 UL1452 solid/18awg quick connect 13 One LEM series LED emergency driver 1000V/90 C 12 Model No.* Input Power Current Ba ery Product Series: LEM = LED Emergency Driver Ba ery Capacity Recharge Time (VAC) (W) (VDC) (ma) (VDC) (Ah) (hr) Default Ba ery Pack* LEM-M U x BCP-NiCd M LEM-M U x BCP-NiCd M UL 13

8 LED Emergency Drivers: Rectangular Case LED Emergency Drivers: Rectangular Case Dimensions: LEM-M U Wiring Diagrams: LEM-M U LEM Driver LEM-M U Ba ery Pack BCP-NiCd M 400 Con gura on #2: Par al Load 45 Con gura on #1: Shared Load 49.6 MAX 133 MAX 21 Model No. Max Overall Length Width Height Moun ng Centers Min Lead Length Weight (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (lbs) LEM-M U BCP-NiCd M* Con gura on #3: Separate Emergency / AC Loads *The driver and ba ery packs are a matched set, which are automa cally paired together when you order. Other ba ery pack op ons are available, but must be special ordered.

9 LED Emergency Drivers: Rectangular Case LED Emergency Drivers: Rectangular Case Dimensions: LEM-M U Wiring Diagrams: LEM-M U LEM Driver LEM-M U Con gura on #1: Shared Load Ba ery Pack BCP-NiCd M Con gura on #2: Par al Load Model No. Max Overall Length Width Height Moun ng Centers Min Lead Length Weight (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (lbs) LEM-M U BCP-NiCd M* Con gura on #3: Separate Emergency / AC Loads *The driver and ba ery packs are a matched set, which are automa cally paired together when you order. Other ba ery pack op ons are available, but must be special ordered.

10 How to Order LEM - C U Input U = Universal VAC Opera ng Current: 0200 = 200mA 0400 = 400mA Max : 036 = 36VDC LED Emergency Drivers: Extra Compact Wa age & Case Type: 0xx = Linear Case Mxx = Rectangular Case Cxx = Extra Compact Case Dxx = Driverless x07 = 7W x18 = 18W McWong s LEM series of LED Emergency Drivers is designed to provide emergency backup power for safety compliance to UL 924; CAN/CSA-C22.2 No and NFPA requirements for 90 minute egress. This product replaces emergency uorescent ballasts when xtures are converted from uorescent to LED light sources, or for new LED luminaires. Standard installa ons require three separate parts to func on: One non-emergency LED driver (AC input) One LEM series LED emergency driver One NiMH ba ery pack Emergency-only installa ons require two separate parts: One LEM series LED emergency driver One NiMH ba ery pack Standard Features: Safety compliance to UL 924; CAN/CSA- C22.2 No and NFPA requirements for 90 minute egress Open circuit / short circuit protec on Opera ng temperature: 32 F/0 C to 122F/50 C Test switch / charging indicator light Emergency reac on me 1 sec Powder coat steel, stainless or galvannealed case Field-replaceable NiMH ba ery pack (x1) with quick connect Min. Lead length: 6 UL1452 solid/18awg 1000V/90 C Product Series: LEM = LED Emergency Driver *Each LED emergency driver model is assigned a default set of ba ery packs, which are automa cally included with your order. Other ba ery pack op ons are available, but must be special ordered. This product series is op mized for use with McWong s LED modules. For ques ons regarding compa bility with light sources from other manufacturers please contact technical support Model No.* Input Power Current Ba ery Ba ery Capacity Recharge Time (VAC) (W) (VDC) (ma) (VDC) (Ah) (hr) Default Ba ery Pack* LEM-C U x BCP-NiMH C LEM-C U x BCP-NiMH C UL

11 LED Emergency Drivers: Extra Compact Dimensions: LEM-C U LED Emergency Drivers: Extra Compact Wiring Diagrams: LEM-C U LEM Driver LEM-C U Ba ery Pack BCP-NiMH C Con gura on #2: Par al Load Con gura on #1: Shared Load 49.6 MAX 150 MAX 17 Model No. Max Overall Length Width Height Moun ng Centers Min Lead Length Weight (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (lbs) LEM-C U BCP-NiMH C* N/A N/A Con gura on #3: Separate Emergency / AC Loads *The driver and ba ery packs are a matched set, which are automa cally paired together when you order. Other ba ery pack op ons are available, but must be special ordered.

12 LED Emergency Drivers: Extra Compact Dimensions: LEM-C U LED Emergency Drivers: Extra Compact Wiring Diagrams: LEM-C U LEM Driver LEM-C U Con gura on #1: Shared Load Ba ery Pack BCP-NiMH C Con gura on #2: Par al Load Model No. Max Overall Length Width Height Moun ng Centers Min Lead Length Weight (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (lbs) LEM-C U BCP-NiMH C* N/A N/A Con gura on #3: Separate Emergency / AC Loads *The driver and ba ery packs are a matched set, which are automa cally paired together when you order. Other ba ery pack op ons are available, but must be special ordered.

13 How to Order LEM - D P U Ba ery Amp-Hour Suffix Code and Max Emergency Power* 1.0 NiCd1.0Ah 9.6V (AA) Max 4W 2.0 NiCd 2.0Ah 9.6V (sc) Max 8W 4.0 NiCd 4.0Ah 9.6V (D) Max 17W Input U = Universal VAC Max Opera ng Current: 0600 = 600mA P = Programmable (DIP switch) Max : 042 = 42VDC Driverless LED Emergency Normal Power & Case Type: 0xx = Linear Case Mxx = Rectangular Case Cxx = Extra Compact Case Dxx = Driverless x07 = 7W x18 = 18W McWong s LEM-Dxx series of Driverless LED emergency products is designed to provide emergency backup power for safety compliance to UL 924; CAN/CSA-C22.2 No and NFPA requirements for 90 minute egress. This product replaces emergency fluorescent ballasts when fixtures are converted from fluorescent to LED light sources, or for new LED luminaires. Standard installa ons of the driverless models require two separate parts to func on: One LEM-Dxx series LED emergency driver One NiCd ba ery pack Normal mode LED so start, emergency mode conversion within 1 second Aluminum low profile housing Field-replaceable NiCd ba ery pack with quick connect Constant current, mul -current selectable output 0-10V dimmable Emergency mode DIP se ngs for 150mA, 300mA, 450mA, or 600mA output current Class I CE & UL Recognized for US and Canada. Suitable for indoor, dry and damp applica ons RoHS compliant (NiCd ba ery excepted) Model No.* Input Max Power Range Max Current Ba ery Ba ery Capacity Product Series: LEM = LED Emergency Driver Recharge Time Emergency Opera on (VAC) (W) (VDC) (ma) (VDC) (Ah) (hr) Ba ery Pack Op ons (See Emergency Power Limits above) LEM-D25-042P0600-U * 6 38* 600* 9.6 See specs , 2.0, 1.0 Ah LEM-D42-042P1000-U * 6 42* 600* 9.6 See specs , 2.0, 1.0 Ah Normal Opera on (VAC) (W) (VDC) (ma) (VDC) (Ah) (hr) LEM-D25-042P0600-U UL Rec. Standard Features: LEM-D42-042P1000-U Safety compliance to UL 924; CAN/CSA-C22.2 No and NFPA requirements for 90 minute egress Open circuit / short circuit protec on Opera ng temperature: 32 F/0 C to 122F/50 C Test switch / charging indicator light * current se ngs must be limited such that the product of the Emergency LED Array mes the Emergency Current does not exceed Ba ery Max Emergency Power ra ng. The driverless LED emergency series is designed for maximum adaptability to accommodate a wide range of outputs. Driverless means that there is no need for a separate AC LED driver; i.e., both normal power and emergency power are regulated by a single self-contained, hybrid AC/emergency driver. The models in this table can be paired with several different ba ery packs. When ordering, you must include a suffix code to indicate the ba ery type desired. For ques ons please contact technical support. Toll Free: (888) Support@McWonginc.com

14 Driverless LED Emergency Driverless LED Emergency Dimensions: LEM-D25-042P0600-U and LEM-D42-042P1000-U Wiring Diagrams: LEM-D25-042P0600-U and LEM-D42-042P1000-U LEM Driver LEM-D25-042P0600-U and LEM-D42-042P1000-U W A L 4.2 Driverless LED Emergency 0-10V L Unswitched L Switched LEM-D25-042P0600-U/ LEM-D42-042P1000-U 0-10V X BLK RED H Ba ery Pack BCP-NiCd , BCP-NiCd , and BCP-NiCd Dipswitch Se ngs: L A D W B E C Dipswitches 1-3 determine the normal mode output current. LEM-D25-042P0600-U LEM-D42-042P1000-U Dipswitches 4 and 5 set various emergency current values. LEM-Dxx-042Pxxxx-U Ba ery Op ons at Typical s Model No. L W H A B C D (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm) (lbs) E Weigh t 4 5 Iemergency Req d Ba ery Typical Ra ng mA 1.0Ah 12V 1.0Ah 24V 2.0Ah 36V LEM-D25-042P0600-U LEM-D42-042P1000-U BCP-NiCd BCP-NiCd Ah 12V mA 26 BCP-NiCd Ah 24V 27 *The driverless LED emergency series is designed for maximum adaptability to accommodate a wide range of outputs. Driverless means that there is no need for a separate AC LED driver; i.e., both normal power and emergency power are regulated by a single self-contained, hybrid AC/emergency driver mA mA * current se ngs must be limited such that the product of the Emergency LED Array mes the Emergency Current does not exceed Ba ery Max Emergency Power ra ng. 1.0Ah 12V 2.0Ah 24V 2.0Ah 36V 2.0Ah 12V 2.0Ah 24V 4.0Ah 36V

15 YEARS OF EXCELLENCE YEARS OF EXCELLENCE Notes: Notes:

16 Limited Warranty LED Emergency Drivers McWong Interna onal, Inc. (herea er referred to as MCWONG ), corporate headquarters located at 1921 Arena Blvd., Sacramento, CA 95834, warrants its products to be free from defects in materials and workmanship from the date of manufacture for the following me periods: Product Series LED Emergency Drivers (all types) Warranty 60 months MCWONG cannot assume any obliga ons or liabili es for consequen al or incidental damages arising from, or in connec on with, the use or performance of its products or other indirect damages with respect to loss of property, revenue or pro t, or cost of removal, installa on or reinstalla on. This limited warranty is not applicable to any product subjected to abnormal stress, such as improper storage, installa on, use and/or maintenance. This warranty is invalid for any product not installed and operated in accordance with all relevant federal, state, and local government regula ons, established industry safety standards, published electrical and temperature ra ngs, and any speci c instruc ons provided by MCWONG for the installa on of the product(s). This limited warranty is extended by MCWONG only to the original or rst end-user purchaser. The standards and condi ons of any tests performed on any MCWONG product(s) by the original purchaser, or by any third party ac ng on behalf of the original purchaser, shall be mutually agreed upon in wri ng and MCWONG shall be noed of, and may be represented at any such tests. Should defects occur a er installa on, and within the warranty period, they should be speci cally described to a MCWONG representa ve. MCWONG shall correct any defects, at MCWONG s op on, by furnishing materials to repair or replace any product(s) that may prove defec ve in materials or workmanship within the warranty period, or by extending a credit in the amount of the purchase price. This does not apply to: (1) damage caused by accident, abuse, mishandling, or dropping; (2) materials which have been subject to unauthorized repair; (3) materials not used in accordance with instruc ons; (4) ordinary wear and tear. MCWONG will be limited to the furnishing of new parts, free of charge, or extending credit for in the amount of the purchase price, in exchange for parts proven to be defec ve and does not include any other costs of removal or installa on. This limited warranty cons tutes the sole and exclusive remedy of the purchase and the exclusive liability of MCWONG, and is in lieu of any and all other warran es, expressed, implied, or statutory as to merchantability, tness for purpose sold, descrip on, quality produc veness, or any other ma er. NO IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY BEYOND THE AFOREMENTIONED WARRANTY PERIOD. Warranty claims can be submi ed by calling our toll free technical support hotline (888) or by visi ng our website and lling out a Warranty Replacement Form (Click on Support >> Warranty Statements). Completed forms should be faxed to (916) or ed to Support@McWonginc.com

LED Emergency Drivers

LED Emergency Drivers LED Emergency Drivers 30 YEARS OF EXCELLENCE Since 1985 Incorporated in the state of California in 1985, McWong International, Inc. has grown to become a strategic supplier of high-quality lighting control

More information

LED Emergency Drivers

LED Emergency Drivers LED Emergency Drivers Incorporated in the state of California in 1985, McWong International, Inc. has grown to become a strategic supplier of high-quality lighting control equipment and related electrical

More information

LED Auxiliary Devices

LED Auxiliary Devices LED Auxiliary Devices 30 YEARS OF EXCELLENCE 1985-2015 Incorporated in the state of California in 1985, McWong International, Inc. has grown to become a strategic supplier of high-quality lighting control

More information

LED Auxiliary Devices

LED Auxiliary Devices LED Auxiliary Devices 30 YEARS OF EXCELLENCE Since 1985 Incorporated in the state of California in 1985, McWong International, Inc. has grown to become a strategic supplier of high-quality lighting control

More information

Power Jumper P8 USER MANUAL AND SAFETY GUIDELINE

Power Jumper P8 USER MANUAL AND SAFETY GUIDELINE Power Jumper P USER MANUAL AND SAFETY GUIDELINE Thank you for choosing Energen Power Jumper. Please always follow basic safety precau ons when using electrical appliances. Read all instruc ons carefully

More information

Amplifier Type K Thermocouple Input Connec on: Thermocouple Input Chanel # Wiring the Thermocouple Ma ng Connector: Use a Type K Therm

Amplifier Type K Thermocouple Input Connec on: Thermocouple Input Chanel # Wiring the Thermocouple Ma ng Connector: Use a Type K Therm Instruc on Manual 8-Channel Type K Thermocouple Amplifier + Accelerometer TCA-MS-K-8-A4 11-2013 www.thesensorconnec on.com Page 1 of 8 Amplifier Type K Thermocouple Input Connec on: Thermocouple Input

More information

Power Specifications. Input Specifications Number of Input Channels 1

Power Specifications. Input Specifications Number of Input Channels 1 Instruc on Manual Single Channel Type K Thermocouple Amplifier TCA-MS-K-1 11-2013 www.thesensorconnec on.com Page 1 of 6 Wiring Schema c: BATTERY AMPLIFIER (-) (+) THERMOCOUPLE PROBE Red Black White DATA

More information

LED Drivers and Modules

LED Drivers and Modules LED Drivers and Modules 30 YEARS OF EXCELLENCE Since 1985 Incorporated in the state of California in 1985 McWong International, Inc. has grown to become a strategic supplier of high-quality lighting control

More information

40W Briefcase Solar Panel & 120W Briefcase Solar Panel

40W Briefcase Solar Panel & 120W Briefcase Solar Panel 40W Briefcase Solar Panel & 120W Briefcase Solar Panel Item 55701 Item 55702 Thank you very much for choosing a Nature Power Product! For future reference, please complete the owner s record below: Model:

More information

Street Sleeper III Air Cleaner Kit for 99 Up Twin Cam 9605

Street Sleeper III Air Cleaner Kit for 99 Up Twin Cam 9605 Street Sleeper III Air Cleaner Kit for 99 Up Twin Cam 9605 THANK YOU FOR CHOOSING CRUSHER! PROTECT YOURSELF AND OTHERS FROM POTENTIAL INJURY AND PROPERTY DAMAGE OR LOSS. PAY CLOSE ATTENTION TO ALL INSTRUCTIONS,

More information

Maintenance Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Maintenance Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL Maintenance Manual Automated Fuel Maintenance System FTI 10A & FTI 20A FUEL TECHNOLOGIES INTERNATIONAL Replacement Manuals Available on Website: www.fueltechnologiesinterna onal.com 03/01/2011 Rev D Fuel

More information

Street Sleeper III Air Cleaner Kit for '08 UP Touring and Trike 9606

Street Sleeper III Air Cleaner Kit for '08 UP Touring and Trike 9606 Street Sleeper III Air Cleaner Kit for '08 UP Touring and Trike 9606 THANK YOU FOR CHOOSING CRUSHER! PROTECT YOURSELF AND OTHERS FROM POTENTIAL INJURY AND PROPERTY DAMAGE OR LOSS. PAY CLOSE ATTENTION TO

More information

Bee Access Products. Aluminum Parapet Clamp. Specifications. Description. Manual M

Bee Access Products. Aluminum Parapet Clamp. Specifications. Description. Manual M Description Made to clamp onto structural parapet walls up to 33 in. thick. Designed for use with suspended scaffolding (for suspension as well as ebacks, except in Canada), or as an anchorage point for

More information

ATD 3-Ton Jack Pack. Jack Size (L x W x H) Saddle Diameter Net Weight

ATD 3-Ton Jack Pack. Jack Size (L x W x H) Saddle Diameter Net Weight Opera ng Instru ons & Parts Manual ATD 3-Ton Jack Pack Model: ATD-7500 Service Jack Model Number: ATD-7504 Capacity Min. Height Max Height Jack Size (L x W x H) Saddle Diameter Net Weight 3 Ton 5-3/8 19-1/2

More information

This Driver Will Operate Constant Current LED Arrays With a Working Voltage Between 11-56VDC And Not Exceeding 20W.

This Driver Will Operate Constant Current LED Arrays With a Working Voltage Between 11-56VDC And Not Exceeding 20W. FHS2-UNV-56S SPECIFICATION SHEET: This Is An Original Product From Fulham Co., Inc Description: Emergency LED Driver For Back-up Lighting. This Driver Will Operate Constant Current LED Arrays With a Working

More information

ATD-80050A 1,500 Lumen SMD LED Underhood Light Owner s Manual Features:

ATD-80050A 1,500 Lumen SMD LED Underhood Light Owner s Manual Features: ATD-80050A 1,500 Lumen SMD LED Underhood Light Owner s Manual Features: ATD80050A_Rev_0218 General Safety Warnings: WARNING: The instruc ons and warnings contained in this manual should be read and understood

More information

LED RECESSED LIGHTS Rev./150827/CLZ

LED RECESSED LIGHTS Rev./150827/CLZ Rev./50827/CLZ Overview Revolucionary built-in driver design with extremely simple and clean appearance. The JIANG H-Series LED recessed lights are using highly luminous-efficient LUMILEDS LUXEON TX luminous

More information

MODEL Model 55. Model 135 CUSTOMER MUST RECEIVE THIS MANUAL AT TIME OF SALE OR AFTER INSTALLATION. Rev 3/17 PN

MODEL Model 55. Model 135 CUSTOMER MUST RECEIVE THIS MANUAL AT TIME OF SALE OR AFTER INSTALLATION. Rev 3/17 PN MODEL 55 135 Model 55 Rated for motors up to 55 horsepower and 250 lbs. Model 135 Rated for motors up to 135 horsepower and 350 lbs. CUSTOMER MUST RECEIVE THIS MANUAL AT TIME OF SALE OR AFTER INSTALLATION

More information

HOOKS HOOKS. VANGUARD STEEL LTD.

HOOKS HOOKS.     VANGUARD STEEL LTD. www.vanguardsteelvancouver.com www.vanguardsteel.com TABLE OF CONTENTS Page Alloy Clevis Grab 1 Alloy Clevis Slip 2 Alloy Clevis Slip with Latch Kit 3 Barrel 4 Carbon Clevis Grab 5 Carbon Clevis Slip 6

More information

2016 MASTER CATALOGUE

2016 MASTER CATALOGUE 2016 2016 MASTER CATALOGUE 2 www.vanguardsteelvancouver.com www.vanguardsteel.com TABLE OF CONTENTS Page Criteria 1 'Golden Pin' Anchor 2 'Golden Pin' Chain 3 'Golden Pin' Safety Anchor 4 Golden Pin Super

More information

MODEL 35 MOTOR LIFT INSTALLATION AND OPERATING INSTRUCTIONS THIS UNIT IS SUITABLE FOR USE WITH AUXILIARY OR KICKER MOTORS UP TO 35 HP OR 150 LBS

MODEL 35 MOTOR LIFT INSTALLATION AND OPERATING INSTRUCTIONS THIS UNIT IS SUITABLE FOR USE WITH AUXILIARY OR KICKER MOTORS UP TO 35 HP OR 150 LBS MODEL 35 MOTOR LIFT INSTALLATION AND OPERATING INSTRUCTIONS THIS UNIT IS SUITABLE FOR USE WITH AUXILIARY OR KICKER MOTORS UP TO 35 HP OR 150 LBS CUSTOMER MUST RECEIVE THIS MANUAL AT TIME OF SALE OR AFTER

More information

LDW-HK. Deadweight Tester / Pressure Balance Hydraulic & Compact Design

LDW-HK. Deadweight Tester / Pressure Balance Hydraulic & Compact Design Deadweight Tester / Pressure Balance LDW-HK Rel. 20120820 Applica ons: Primary standard for defining the pressure scale in a range up to 1200 bar hydraulic Reference instrument for factory and calibra

More information

Model 2314 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Model 2314 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority Model 2314 Series Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com shop.sscor.com Email: marketing@sscor.com techsupport@sscor.com Tel 1+818-504-4054

More information

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Open Display Merchandiser Installation and Operation Manual Please read this manual completely

More information

LED STREET LIGHTS Rev./150617/AL

LED STREET LIGHTS Rev./150617/AL Rev./150617/AL Overview An elegant design with LED module combined with highly efficient PHILIPS LUXEON T LED luminous source and a highly reliable Mean Well driver series HLG. The H2-Series LED street

More information

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria

More information

HBC-20 - LED HIGH BAY

HBC-20 - LED HIGH BAY To prevent death, injury or damage to property, this product must be installed in accordance to National Electrical Code (NFPA70) in the US or Canadian Electrical Code (CSA.) in Canada. Risk of fire or

More information

G3PE-Single-phase. Solid State Relays for Heaters

G3PE-Single-phase. Solid State Relays for Heaters Solid State Relays for Heaters Single-phase CSM_Single-phase_DS_E Compact, Slim-profile SSRs with Heat Sinks. s with No Zero Cross for a Wide Range of Applications. RoHS compliant. s also available with

More information

BLOCKS VANGUARD STEEL LTD. BLOCKS.

BLOCKS VANGUARD STEEL LTD. BLOCKS. BLOCKS www.vanguardsteelvancouver.com www.vanguardsteel.com BLOCKS TABLE OF CONTENTS General Information 1 SK-05 Korean Type 2 V-1800 Snatch Block with Hook 3 V-1900 Snatch Block with Swivel Shackle 4

More information

Power Series Amplifiers Installation Manual / Quick Start Guide

Power Series Amplifiers Installation Manual / Quick Start Guide REL T REB BAL FADE VOL CD -R/R W AU i E JPTH IN X LOC/DX 1 2 INT 5 6 BAND SCAN i MUTE 3 RPT 4 SHF DN CHANGER UP i BA X- SS SU B-W MONO AS /PS DIS P MODE Installation Assistance For installation assistance,

More information

LED Auxiliary Devices

LED Auxiliary Devices LED uxiliary Devices Page 21 MTM Series (V) Model Number MTM - Slimline Stepdown uto-transformer Dimensions (in)* B W H M MTM0030252C MTM0030227C MTM0030224C MTM00304852C MTM00303452C MTM00304827C MTM00304824C

More information

Type Flexair Pneumatic Pressure Control Valves

Type Flexair Pneumatic Pressure Control Valves Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Type Flexair Pneumatic Pressure Control Valves Catalog pages from

More information

Instruction Sheet. SFR Series. Swing Frame rack

Instruction Sheet. SFR Series. Swing Frame rack Instruction Sheet SFR Series Swing Frame rack THANK YOU Thank you for purchasing the SFR Series Swing Frame Rack. Please read these instructions thoroughly before installing/assembling this product. PRODUCT

More information

MODEL AL ADJUSTABLE ALUMINUM BRACKET DESIGNED FOR AUXILIARY MOTORS UP TO 15HP INSTRUCTION MANUAL

MODEL AL ADJUSTABLE ALUMINUM BRACKET DESIGNED FOR AUXILIARY MOTORS UP TO 15HP INSTRUCTION MANUAL MODEL 55-0407AL ADJUSTABLE ALUMINUM BRACKET DESIGNED FOR AUXILIARY MOTORS UP TO 15HP INSTRUCTION MANUAL This is the side that faces the transom Ver cal travel : 10 inches [25.4 cm] Setback up: 8 3/4 inches

More information

Distributed by: LED Hawaii Kauhi St. Kapolei, HI / E: / Phone: (808) LED HIGH BAY LIGHTS Rev.

Distributed by: LED Hawaii Kauhi St. Kapolei, HI / E: / Phone: (808) LED HIGH BAY LIGHTS Rev. Distributed by: LED Hawaii 91-335 Kauhi St. Kapolei, HI 96707 / E: sales@ledhawaii.com / Phone: (808) 306-7873 Rev./150617/AL Overview Revolucionary built-in driver design with extremely simple and clean

More information

Cabling for power, control, and video must be run to the installation site before the mount is installed.

Cabling for power, control, and video must be run to the installation site before the mount is installed. User Installation User Guide Guide & Operation Manual V940D V-20B-A-2 V940D Mounting Kits Mounting Pole Mounting Kits Adapter X532-11-00 Vicon Industries Inc. does not warrant that the functions contained

More information

Installation Instructions

Installation Instructions Installation Instructions Bradley Touch Time Valve for Column Showers Table of Contents Pre-Installation Information...............2 Touch Time Valve Installation............3 Touch Time Valve Wiring Diagram........4

More information

Series 2100 Operating Instructions

Series 2100 Operating Instructions Series 2100 Operating Instructions Installation Instructions Visit the link below or scan the QR code to watch a detailed installation video: http://triteqlock.com/fresh After the lock, temperature probe,

More information

Applica on Note 109. Switch for Smart Locks. Relevant Products: Introduc on. Smart Lock System Diagram. Features and Benefits

Applica on Note 109. Switch for Smart Locks. Relevant Products: Introduc on. Smart Lock System Diagram. Features and Benefits Relevant Products: CT510 Series Digital Switch Introduc on New keyless, smart locks are emerging and replacing the tradi onal key deadbolt locks. With this new technology, the key is no longer used and

More information

TUV Listed LED Gas Station Lights LED STREET LIGHTS LED GAS STATION LIGHTS

TUV Listed LED Gas Station Lights LED STREET LIGHTS LED GAS STATION LIGHTS TUV isted ED Gas Station ights ED STREET IGHTS ED GAS STATION IGHTS TUV isted ED GAS STATION IGHTS PRODUCT CATAOG Overview The ENETEC H /H5-Series ED Gas Station lights are using UMIEDS UXEON 00 D luminous

More information

SUB-8100 Active Bass Subwoofer

SUB-8100 Active Bass Subwoofer SUB-8100 Active Bass Subwoofer The informa on enclosed in this installa on guide is to be used as merely an outline to assist you during the process of installa on. This guide does not cover every installa

More information

NPC-2006 Nitrous Power Controller

NPC-2006 Nitrous Power Controller NPC-2006 Nitrous Power Controller Induction Solutions 16121 Flight Path Dr Brooksville, FL 34604 352-593-5900 Phone 352-593-5901 Fax email: info@inductionsolutions.com 2 What is Included with the NPC 2006

More information

Thomson Engineering Design Ltd. Drag Clamp. Operator s Instructions. Original Document in English Language. Issue 2 March 2015

Thomson Engineering Design Ltd. Drag Clamp. Operator s Instructions. Original Document in English Language. Issue 2 March 2015 Thomson Engineering Design Ltd Drag Clamp Operator s Instructions Original Document in English Language Issue 2 March 2015 Document Number: DC-Inst-01 Issue: 02 Date: March 2015 Introduction The Thomson

More information

IC Series Owners Manual IC1000 IC2000 IC3000

IC Series Owners Manual IC1000 IC2000 IC3000 IC Series Owners Manual IC1000 IC2000 IC3000 The Excelsior Power IC series of inverter/chargers have been carefully designed and manufactured to provide you years of reliable opera on. Please read this

More information

MaxLite LED UTILITY WRAP FIXTURES

MaxLite LED UTILITY WRAP FIXTURES General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information

Power Distribution Units

Power Distribution Units Power Distribution Units AP9562, AP9563, and AP9564 AP9562, AP9563, and AP9564 are 15- and 20-amp Rack Power Distribution Units (PDUs) that provide 120-volt power to rack-mounted equipment. AP9562, -.,

More information

Digital Clock model 75100C

Digital Clock model 75100C Instruction Manual Digital Clock model 75100C CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits... 3 Clock Setup... 4 Set the Time & Date... 5 Care

More information

Instant Wine Aerator USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE

Instant Wine Aerator USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE Instant Wine Aerator USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE Table of Contents Section 1. Information 1.1 Introduction 1.2 Safety Warnings Section 2. Product Parts Section 3. Product Information

More information

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range Model:M5B/M5W/M5N Installation Guide Website: www.flexispot.com Tel: 1-855-421-2808 Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range 33 Ibs (15 KG) 4.4 Ibs (2

More information

STC Air Cylinders. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Air Cylinders

STC Air Cylinders. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Air Cylinders Catalog: PUB 06 CYL STC Advanced Design Precision Engineered Fine Quality Excellent Prices connects fluid power to industrial automation F1 Table of Contents STC Air Cylinder Numbering System............F2

More information

GRATIS - FREE OF CHARGE:

GRATIS - FREE OF CHARGE: Rel. 20150206 Applica ons: Primary standard for defining the pressure scale in a range up to 1200 bar hydraulic Reference instrument for factory and calibra on laboratories for the tes ng, adjustment and

More information

GEAR PUMP SYSTEMS PROCESS & CHEMICAL FEED EQUIPMENT

GEAR PUMP SYSTEMS PROCESS & CHEMICAL FEED EQUIPMENT PROCESS & CHEMICAL FEED EQUIPMENT Oil & Gas Power Genera on Chemical Processing Mining Pulp and Paper Water Resources Pharmaceu cal GEAR PUMP SYSTEMS USA +1.251.662.1250 phone +1.251.662.8250 fax Gear

More information

CD52 Bandit Magne c Pig Passage Signaler

CD52 Bandit Magne c Pig Passage Signaler CD52 Bandit Magne c Pig Passage Signaler FOR OVER TEN YEARS, THE CD52 BANDIT has meant simple, reliable, and durable pipeline pig passage detection in the world s most demanding environments. Non-intrusive

More information

Operating and programming instructions at =AMPS or =WATTS REPLACED PERCENTAGE FROM LAST DISCHARGE

Operating and programming instructions at   =AMPS or =WATTS REPLACED PERCENTAGE FROM LAST DISCHARGE TM-2030 TriMetric Battery Monitor Installation and User Guide TM 2030-RV Bogart Engineering CHARGING BATTERY REMINDERS when flashing-meets "CHARGED" criteria =TIME TO CHARGE =TIME FULL TO EQUALIZE =BATT.

More information

RANGE HOODS USER INSTRUCTIONS

RANGE HOODS USER INSTRUCTIONS RANGE HOODS USER INSTRUCTIONS Model: Advanta Pro III 30 & 36 IMPORTANT SAFETY INSTRUCTIONS Carefully read the following important information regarding installation safety and maintenance. Keep these instructions

More information

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#: ST-70 CONTROL OPERATING MANUAL REVISION DATE: 05-15-07 PART#: 98-0002-09 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE DEPARTMENT. IF FURTHER HELP

More information

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

INSTALLATION/OWNER'S MANUAL DP  Woofer in Enclosure INSTALLATION/OWNER'S MANUAL DP1000 10" Woofer in Enclosure Installation Thank you for purchasing the DP1000 10" Woofer with enclosure. Although Dual has attempted to make sure all of the information contained

More information

Huntington Mechanical Labs, Inc.

Huntington Mechanical Labs, Inc. R Huntington Mechanical Labs, Inc. Huntington Mechanical Labs, Inc. 13355 Nevada City Avenue Grass Valley, CA. 9595 Toll Free: 800-227-8059 Local: 530-273-135 FAX: 530-273-165 Sales email: vacman@huntvac.com

More information

PS Series Owners Manual PS300 PS1000 PS2000 PS3000 PSX2000 PSX3000 PS5000

PS Series Owners Manual PS300 PS1000 PS2000 PS3000 PSX2000 PSX3000 PS5000 PS Series Owners Manual PS300 PS1000 PS2000 PS3000 PSX2000 PSX3000 PS5000 The Excelsior Power PS series of inverters have been carefully designed and manufactured to provide you years of reliable opera

More information

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7 Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7 1 Table of Contents Dimensions... 3 Technical Specifications... 4 Communication... 5 Programming... 6 Data Collection and

More information

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR) TERMS OF USE 1. Watts pricing and product data is subject to change without notice and such changes supersede all previous versions. 2. Watts data is to be used as provided. Watts is not responsible for

More information

BUYERS GUIDE FOR TYPE C DRIVERS. Programmable vs. Field Adjustable LED Drivers

BUYERS GUIDE FOR TYPE C DRIVERS. Programmable vs. Field Adjustable LED Drivers BUYERS GUIDE FOR TYPE C DRIVERS Programmable vs. Field Adjustable LED Drivers Published: January, 2018 What are the different TLED system types? There are three basic types of linear LED tube systems.

More information

Valve Lockouts. Valve lockouts are available to suit all types of valve including ball valve, gate valve, globe valve and plug valve.

Valve Lockouts. Valve lockouts are available to suit all types of valve including ball valve, gate valve, globe valve and plug valve. Valve lockouts are available to suit all types of valve including ball valve, gate valve, globe valve and plug valve. A well fi ed valve lockout will provide protec on against accidental or unauthorised

More information

SERIES LVB Universal Globe Valve Linkage

SERIES LVB Universal Globe Valve Linkage SERIES LVB Universal Globe Valve Linkage Publication SLVB-101 Issue 08/14 Issue 08/14 Rev. A LVB series linkages are available for 1/2 through 6 globe valves made by most manufacturers like Johnson Controls,

More information

Power Conversion Products

Power Conversion Products Power Conversion Products Table of Contents Our Mission Mission Statement... 3 Order Information... 3 Terms of Sale... 3 Warranty... 3 Power Supplies Desktop Switching Power Supplies... 4 Linear Power

More information

SERIES 1000 ELECTRIC ACTUATORS

SERIES 1000 ELECTRIC ACTUATORS SERIES 1000 ELECTRIC ACTUATORS DESIGN FEATURES Series 1000 On-Off Rotary Electric Actuator Standard Features SERIES 1000 ELECTRIC ACTUATORS Torque Output Range: 434in-lb to 17,700in-lb Housing: NEMA 4,

More information

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7 Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7 1 Table of Contents Dimensions... 3 Dimensions of SafePace 100 Radar Sign with Full YOUR SPEED Sign Face... 4 Dimensions of

More information

Installation, Operation and Maintenance. VA(M)S24-27 (T)-T Series Actuator

Installation, Operation and Maintenance. VA(M)S24-27 (T)-T Series Actuator 102-526 Applications The VA(M)S24-27-(T)-T Series On/Off Electric Spring Return Actuators are direct-mount valve actuators that operate on AC 24 V power at 50/60 Hz, DC 24 V power, or AC 85 to 264 V power

More information

Vacuum Assisted Oil Mist Eliminators Reciprocating Engines and Turbines

Vacuum Assisted Oil Mist Eliminators Reciprocating Engines and Turbines Vacuum Assisted Oil Mist Eliminators Reciprocating Engines and Turbines Our Vacuum Assisted Oil Mist Eliminators are designed for field upgrades and new reciproca ng engines and turbine installa ons around

More information

Installation Manual. Ven la on Requirements Electrical Requirements Temp & Brightness Sensors Removing a Module Moun ng Guidelines

Installation Manual. Ven la on Requirements Electrical Requirements Temp & Brightness Sensors Removing a Module Moun ng Guidelines Installation Manual Page 1 - Page 2 - Page 3 - Page 4 - Pages 5-9 - Ven la on Requirements Electrical Requirements Temp & Brightness Sensors Removing a Module Moun ng Guidelines Ven la on Electronic Message

More information

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter

More information

Piggy Back Products.

Piggy Back Products. Piggy Back Products. 01 Piggy Back systems work with an exis ng ECU (Engine Control Unit) and therefore do not replace the vehicle s original ECU. Piggy Back means just that to piggy back or go on top

More information

- Data Brochure D 156. Difference Setpoint Control 156. Item 06/10

- Data Brochure D 156. Difference Setpoint Control 156. Item 06/10 - Data Brochure Difference Setpoint Control 156 D 156 06/10 The Difference Setpoint Control 156 is designed to operate an on/off pump to transfer heat from a heat source to a storage tank. The control

More information

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers DWS404 DWS524 DWS654 DWS684 DWS694 DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers PREPARATION Safety Guidelines Thank you for purchasing the DWS Series car speakers. Although Dual has attempted

More information

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE. PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.. (1) RG1000 EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY (1) 3-IN-1 USB CABLE (1) RG1000 EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY

More information

SERIES 7400 THREE PIECE BALL VALVES

SERIES 7400 THREE PIECE BALL VALVES SERIES 7400 THREE PIECE BALL VALVES Publication S7400-101E Issue 05/16 SERIES 7400 Body Stainless Steel (A351-CF8M) Carbon Steel (A216-WCB) Seat TFM* RPTFE PEEK ALTA Stem 316 Stainless Steel ISO 5211 Mounting

More information

Vacuum Assisted Oil Mist Eliminators Reciprocating Engines & Turbines

Vacuum Assisted Oil Mist Eliminators Reciprocating Engines & Turbines Vacuum Assisted Oil Mist Eliminators Reciprocating Engines & Turbines Our Vacuum Assisted Oil Mist Eliminators are designed for field upgrades and new reciproca ng engines and turbine installa ons around

More information

SUPERCAPACITORS. The world s first supercapacitor-based energy storage system

SUPERCAPACITORS. The world s first supercapacitor-based energy storage system SUPERCAPACITORS The world s first supercapacitor-based energy storage system Meeting the energy demands of today while unlocking the potential of the world s energy future. The evolution has begun SIRIUS

More information

i400s Calibration Information Introduction

i400s Calibration Information Introduction i400s AC Current Clamp Introduction XWWarning To avoid electric shock or injury, do not perform the performance tests or calibration procedures unless you are qualified to do so. The information provided

More information

Power Distribution Units AP9560 & AP9561

Power Distribution Units AP9560 & AP9561 Power Distribution Units AP9560 & AP9561 AP9560 and AP9561 are 30-amp Rack-mount Power Distribution Units (PDUs) that provide 120-volt or 208-volt power to rack-mount equipment. AP9560. - AP9561,, 12-foot

More information

Pump Package Conversion Kits

Pump Package Conversion Kits Instructions - Parts Pump Package Conversion Kits A0B ENG To install an L00CM or L500CM Check-Mate Displacement Pump on an existing motor. For professional use only. Not for use in explosive atmospheres.

More information

2016 MASTER CATALOGUE

2016 MASTER CATALOGUE 2016 2016 MASTER CATALOGUE ALLOY LIFTING 2 www.vanguardsteelvancouver.com www.vanguardsteel.com ALLOY LIFTING TABLE OF CONTENTS Page Chain 1 Clevis Grab Hook 2 Clevis Slip Hook 3 Connecting Links 4 Master

More information

Instruction Sheet DWRSR-ZL. Zero Clearance Latch

Instruction Sheet DWRSR-ZL. Zero Clearance Latch Instruction Sheet DWRSR-ZL Zero Clearance Latch US Patent 7,188,570 B2 THANK YOU Thank you for purchasing the DWRSR-ZL Zero Clearance Latch. Please read these instructions thoroughly before installing

More information

INSTALL GUIDE Dodge/RAM 5.7L HEMI

INSTALL GUIDE Dodge/RAM 5.7L HEMI INSTALL GUIDE 2009-2017 Dodge/RAM 5.7L HEMI TABLE OF CONTENTS 3 GETTING STARTED 3 PARTS LIST 4 INSTALLATION INSTRUCTIONS 4 REMOVING THE STOCK INTAKE ASSEMBLY 6 INSTALLING THE AIR FILTER 7 INSTALLING THE

More information

LBH / LBFR SERIES. Instruction Sheet. Telescoping Lacer Bar

LBH / LBFR SERIES. Instruction Sheet. Telescoping Lacer Bar Instruction Sheet LBH / LBFR SERIES Telescoping Lacer Bar THANK YOU Thank you for purchasing the LBH / LBFR Series Telescoping Lacer bar. Please read these instructions thoroughly before installing this

More information

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter Battery Back-up BBM-1225 Owner's Manual Please read this manual BEFORE installing your inverter owner's MAnUAL index section 1 Safety Instructions... 3 section 2 Layout and Dimensions... 4 section 3 Description

More information

HPx-JDx3-xx HARNESS INSTALLATION

HPx-JDx3-xx HARNESS INSTALLATION HPx-JDx3-xx HARNESS INSTALLATION Conversion Manual 09040106b HEADSIGHT.COM 574.546.5022 About Headsight Headsight Contact Info Headsight, Inc. 4845 3B Road Bremen, IN 46506 Phone: 574-546-5022 Fax: 574-546-5760

More information

Signal Head Crane Maintenance Plan and Instructions

Signal Head Crane Maintenance Plan and Instructions Signal Head Crane Maintenance Plan and Instructions Maintenance and Inspection Instructions for the Thomson Engineering Design Ltd Signal Head Crane Original Document in English Language Issue 2: January

More information

CT4880 Collaboration Huddle Table Assembly Instructions

CT4880 Collaboration Huddle Table Assembly Instructions CT4880 Collaboration Huddle Table Assembly Instructions Monitor, monitor stand and chairs are not included. Thank you for choosing the CT4880 Collaboration Huddle Table from AmpliVox Portable Sound Systems.

More information

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12 miconverter 18-Module Rack-Mount Power Chassis User Manual Page 12 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 General and Copyright Notice This publication is protected by

More information

INSTALLATION & OWNER'S MANUAL

INSTALLATION & OWNER'S MANUAL INSTALLATION & OWNER'S MANUAL THE EAGLE POWER I BATTERY BACK UP PHONE (818) 764-6690 / TOLL FREE (800) 708-8848 PRE INSTALLATION INSTRUCTIONS BEFORE PROCEEDING WITH INSTALLATION READ THIS MANUAL THOROUGHLY

More information

LED FLOOD LIGHTS Rev./150910/CLZ

LED FLOOD LIGHTS Rev./150910/CLZ Rev./090/CLZ Overview Revolucionary built-in driver design with extremely simple and clean appearance. The JIANG H-Series LED flood lights are using highly luminous-efficient LUMILEDS LUXEON TX luminous

More information

Parts Manual Vermeer/ McLaughlin Mud System 230P

Parts Manual Vermeer/ McLaughlin Mud System 230P 2006 Perimeter Road. Greenville, SC 29605 Toll Free: 800/435-9340 - Phone: 864/277-5870 Fax: 864/235-9661 - Website address: www.mightymole.com Email address: mmole@mightymole.com Parts Manual Vermeer/

More information

EMISSION CONTROL WARRANTY STATEMENT

EMISSION CONTROL WARRANTY STATEMENT EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The California Air Resources Board, U.S. EPA and Zenith Power Products LLC (ZPP) are pleased to explain the emission control system

More information

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer PREPARATION Getting Started Thank you for purchasing the Dual BAK1500 compact amplified subwoofer. Although Dual has attempted to ensure

More information

Force Test Stands Series ES MODEL ES05

Force Test Stands Series ES MODEL ES05 Force Test Stands Series ES MODEL ES05 User s Guide Model ES05 Thank you! Thank you for purchasing a Mark-10 Series ES Force Measurement Test Stand. We are confident that you will get many years of service

More information

Chek-A-Cell TM. Instruction Manual Rev A 8/12

Chek-A-Cell TM. Instruction Manual Rev A 8/12 Chek-A-Cell TM Instruction Manual 84-867 Rev A 8/12 INTRODUCTION: The CHEK-A-CELL is a digital battery load tester for all types of batteries in the 5.75 Volt to 20 Volt, 1 to 20 Amp Hour range. Rechargeable

More information

Motor Mounting Kits. Instructions J EN. 16C487 Motor Coupler Kit includes 2.25 in. (57.2 mm) key For NEMA 182/184 TC Frame ATEX Electric Motors

Motor Mounting Kits. Instructions J EN. 16C487 Motor Coupler Kit includes 2.25 in. (57.2 mm) key For NEMA 182/184 TC Frame ATEX Electric Motors Instructions Motor Mounting Kits 31160J EN To install electric motors on E-Flo 4-Ball Piston Pumps. For professional use only. (Kits do not include motors.) 16C487 Motor Coupler Kit includes 2.2 in. (7.2

More information

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator www..c Installation & Operation Manual Electrak 100 Series / Electromechanical Linear Actuator Thomson has many years of experience designing and manufacturing linear actuators for a wide variety of applications

More information

Charging with AC (wall) Charger

Charging with AC (wall) Charger Kodiak User Guide Unpacking Your Kodiak Included in the box: A. Kodiak generator B. AC Charger Charging Your Kodiak (see diagram on opposite side for port locations) Charging with Solar The Kodiak provides

More information