DATA SHEET. Model: TG4 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL
|
|
- Rolf Stafford
- 5 years ago
- Views:
Transcription
1 DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL DATA SHEET Model: TG4 Revision Date: September 2015 Output: kw Revision Number: DS.TG4.16 All models approved to current British and European Standards. All burners in the T.G. range are of the fan assisted, nozzle mix type and operation is fully automatic. All models have been independently tested to the European Standard pr EN676 - Automatic forced draught burners for gaseous fuels. CE approval numbers for the TG4 Series burners are: TG410, 415, 420 CE 86/CL/89 1
2 DS.TG4.16 BURNER DIMENSIONS - HIGH / LOW & ELECTRO / PNEUMATIC - TG410 / 415 BURNER All dimensions in mm unless otherwise stated. The minimum standard dimension for 'PROJ' is 230mm. However, it can be varied to suit application. Requirements should be stated when unit is ordered. Dimension E is the average swing radius; this can vary on non-standard burners. Burner shown is right-hand hinge; left-hand hinge is an available option. Please check the issue number to ensure validity. 2
3 DS.TG4.15 BURNER DIMENSIONS - HIGH / LOW & ELECTRO / PNEUMATIC - TG420 BURNER All dimensions in mm unless otherwise stated. The minimum standard dimension for 'PROJ' is 230mm. However, it can be varied to suit application. Requirements should be stated when unit is ordered. Dimension E is the average swing radius; this can vary on non-standard burners. Burner shown is right-hand hinge; left-hand hinge is an available option. Please check the issue number to ensure validity. 3
4 BURNER DIMENSIONS - ELECTRONIC MODULATION - TG410 / 415 BURNER DS.TG4.16 All dimensions in mm unless otherwise stated. The minimum standard dimension for 'PROJ' is 230mm. However, it can be varied to suit application. Requirements should be stated when unit is ordered. Dimension E is the average swing radius; this can vary on non-standard burners. Burner shown is right-hand hinge; left-hand hinge is an available option. Please check the issue number to ensure validity. 4
5 BURNER DIMENSIONS - ELECTRONIC MODULATION - TG420 BURNER DS.TG4.16 All dimensions in mm unless otherwise stated. The minimum standard dimension for 'PROJ' is 230mm. However, it can be varied to suit application. Requirements should be stated when unit is ordered. Dimension E is the average swing radius; this can vary on non-standard burners. Burner shown is right-hand hinge; left-hand hinge is an available option. Please check the issue number to ensure validity. 5
6 DS.TG4.15 BURNER RATING GRAPH & SCHEMATICS 6
7 DS.TG4.16 BURNER SCHEMATICS - HIGH / LOW & PNEUMATIC MODULATING Typical Gas Line Schematic for High / Low & Pneumatic Modulating Burners with Gas Pilot Line Typical Gas Line Schematic for High / Low & Pneumatic Modulating Burners without Gas Pilot Line 7
8 BURNER SCHEMATICS - ELECTRICAL MODULATING DS.TG4.16 Typical Gas Line Schematic for Electronic Modulating Burners without Gas Pilot Line Typical Gas Line Schematic for Electronic Modulating Burners with Gas Pilot Line (Single Valve) 8
9 DS.TG4.16 Typical Gas Line Schematic for Electronic Modulating Burners with Gas Pilot Line (Twin Valve) Typical Gas Line Schematic for Electronic Modulating Burners with Gas Pilot Line (Twin Valve) and Optional LPG / Propane Connection 9
10 DS.TG4.15 STANDARD SPECIFICATION DATA BURNER TYPE Firing Rate kw GAS VOLUME (m3/hr) *1 MIN MAX MIN MAX High / Low FIRING MODE OPTIONS Electro / Pneumatic Modulation Electronic Modulation *2 TG410ZM TG415YM TG420YM Motor kw Voltage Hz Ph Running Current Starting Current (without inverter) Amp 48 Amp Amp 64 Amp Amp 88 Amp *1 Based on Nat. Gas C.V 10.4 kw/m3 *2 - Fitted with a Ratiotronic 6000 system COMBUSTION HEAD The Dunphy combustion head incorporates a two-stage fuel/air mixing system which eliminates low frequency resonance and allows maximum combustion efficiency with minimum emission levels. This system combined with smooth ignition and extreme reliability make Dunphy combustion equipment the most sensible choice for all heating and process applications. ULTRA LOW NOx BURNERS All Dunphy T-Series burners are fitted with low NOx combustion heads as standard equipment. As an optional extra all burners in this range can be fitted with an internal flue gas recirculation system to achieve ultra low NOx emissions. Dunphy Combustion Ltd have a policy of continuous development and reserve the right to change prices and specifications without prior notice. Dunphy Combustion Ltd. has a policy of continuous development and reserve the right to change prices and specifications without prior notice 10
DATA SHEET. Model: TG3 Revision Date: September DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL
DUNPHY COMBUSTION LTD. Queensway Rochdale England OL11 2SL DATA SHEET Model: TG3 Revision Date: September 2015 Output: 200 2950 kw Revision Number: DS.TG3.19 All models approved to current British and
More informationDoing more for clean environment and energy saving
Doing more for clean environment and energy saving Rütli Burners Switzerland AG is a worldwide leading industrial burner solution supplier. Our head quarter is located in Schaffhausen, Switzerland one
More informationD SERIES TECHNICAL DATA INFORMATION PACKET
D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,
More informationD SERIES TECHNICAL DATA INFORMATION PACKET
D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data
More informationS1 SERIES TECHNICAL DATA INFORMATION PACKET
S1 SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions S1G, S1L, S1LG Technical Data Sheet...3 Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions S1E, S1EG Technical
More informationPROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.
PROFIRE xl Series burners 37.8 TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications. Innovative Technology. Superior performance a technician can trust. The ProFire XL series,
More informationKey facts. Combustion, biofuels and zero net carbon. Capturing the economic benefits of carbon neutral fuels
Key facts Combustion, biofuels and zero net carbon Capturing the economic benefits of carbon neutral fuels Oil pre-heat Testing variations in biofuel characteristics and the importance of filtration Waste
More informationRDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL
The Riello RDB series of one stage light oil and kerosene burners is available in eleven basic models, with an output ranging from 16,8 to 120 kw, in three different structures. The models are available
More informationIMMERSION FIRED HOT WATER BOILER
918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series
More informationDUAL FUEL BURNERS TD/TAD4 GENERAL INFORMATION AND OPERATING MANUAL. 1 of 165
DUAL FUEL BURNERS TD/TAD4 GENERAL INFORMATION AND OPERATING MANUAL 1 of 165 Revision Table Operating Instructions For TD/TAD4 Dual Fuel Burner Rev No. Description Date By 1 2 3 4 Emergency stop information
More informationAirejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:
Airejet Low NOx Coal Burner Unique low NO X coal burner with center air jet for use with overfire air (OFA) systems. Sleeve Damper Actuator Core Air Inlet Duct and Damper Pitot Grid Outer Spin Vanes Inner
More informationProduct Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT
The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures
More informationproduct Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable
product Information on oil, gas and dual fuel burners Minimale Industrial Emissionswerte burners mit Gas Industrial burners 1, 11,7 kw flexible and reliable Weishaupt Industrial Burners: Flexible and reliable
More information1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER
CAPABILITIES Industry leading low NOx emissions High momentum. luminous flames at all furnace temperatures High release rates with moderate main combustion air pressure Good turndown with flame characteristics
More informationPARTS LIST GAS TILTING SKILLETS MODELS: GLTS-30 GLTS-40
PARTS LIST GAS TILTING SKILLETS MODELS: CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416) 746-8324 PRINTED IN CANADA PART NUMBER
More informationNOx-Beta Ultra Low NOx Burners
NOx-Beta Ultra Low NOx s February NOx-Beta Features Ultra low NOx without any performance loss Staged air principle no external NOx reducing devices or FGR needed Robust, well engineered construction Cost
More informationinfo NO x emissions <15 ppm 4LN version gas burners (with Flue Gas Recirculation) Information on Ultra Low NO x gas burners
info Information on Ultra ow O x gas burners O x emissions
More informationM SERIES TECHNICAL DATA INFORMATION PACKET
M SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions MG, MM#2, MMG#2 Technical Data Sheet... Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions MM, MMG Technical
More informationRESIDENTIAL & LIGHT DUTY COMMERCIAL GAS REPLACEMENT PARTS LIST Ultra Low NOx High Input Direct Vent Energy Saver Models
RESIDENTIAL & LIGHT DUTY COMMERCIAL GAS REPLACEMENT PARTS LIST Ultra Low NOx High Input Direct Vent Energy Saver Models UDH1, UDH Series Includes Hydrojet Total Performance System Effective: September,
More informationRoofing Tests for European Roofing Products ENV 1187 Test 1, 2, 3 and 4
Roofing Tests for European Roofing Products ENV 1187 Test 1, 2, 3 and 4 THE BENCHMARK IN FIRE TESTING ENV 1187 Tests for European Roofing Products This ENV 1187 describes four methods for determining the
More informationGULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.
The Riello Gulliver BS series of one stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards regarding
More information420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS
MDEL C/C S IR R STEM LIHT IL TMIZIN FRCED DRFT BURNERS Power Flame s Versatile High Performance ir or Steam tomizing Light il Burner djustable Premix Firing Head Produces optimum fuel/air mixture within
More informationPower Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948
More informationRL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw
LOW NOx T The RL/M BLU burners series covers a firing range from 360 to 1023 kw, and it has been designed for use in hot or superheated water boilers, hot air or steam generators and diathermic oil boilers.
More informationGULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.
The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards
More informationFD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP
FD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP Features of the FD68 Series RUGGED INDUSTRIAL DESIGN SUPERIOR HOUSING Cylindrical windbox design provides
More informationTEMINOX GLS. Mono-/Duoblock Pressure Jet. Advantages. Capacity range Fuels
Mono-/Duoblock Pressure Jet TEMINOX GLS Advantages Highest quality standard by latest state of production engineering, application of ISO 9001 quality management system European type approval (EN 267 /
More informationGENERAL INFORMATION DHDAT
`DH` SERIES OIL PUMPS GENERAL INFORMATION DHDAT01 01 04 `DH` SERIES GENERAL DESCRIPTION The oil pump is a vital part of any oil fired heating plant, whether being used as a transfer pump for pumping oil
More informationMULTIFIRE. High temperature dual fuel burner
MULTIFIRE High temperature dual fuel burner High temperature burners - MULTIFIRE 3-11.3-1 Operates on-ratio or with excess air to meet the specific demands of your combustion process needs Burns most clean,
More informationD SERIES BURNERS 4.2 TO 42.0 MMBTU/HR
D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Industrial Combustion offers complete boiler
More informationXID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE
IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner
More informationGPG14M. 2- to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE
ooling apacities:,000 to 57,500 BTU/h Heating apacities: 40,000 to 10,000 BTU/h GPG14M - to 5-Ton Packaged Gas/Electric Units 14 SEER / 81% AFUE ontents Nomenclature... Product Specifications... Expanded
More informationproduct WM 10 oil, gas and dual fuel version Weishaupt monarch WM10 burners flexible application Information on oil, gas and dual fuel burners
product Information on oil, gas and dual fuel burners WM 10 oil, gas and dual fuel version Weishaupt monarch WM10 burners flexible application Advanced technology starts from tradition The new monarch
More informationPROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET
PROFIRE V SERIES TEHNIA DATA INFORMATION PAKET Technical Data Uncontrolled Emissions onfiguration (VG, V, VG) 1.3-16.8 MM BTU/H NG; 9.3-120 GPH #2 OI U listed with choice of NFPA, SD-1, GAP, and FM for
More information13 GCS X A X Nominal SEER Minor Revision Number
PA C KA G E D G A S / E L E C T R I C 13GCSX ELITE SERIES Residential - R-410A P R O D U C T S P E C I F I C AT I O N S Bulletin No. 210422 April 2013 Supersedes June 2012 SEER - 13.00 AFUE - 80% 2 to
More informationCOMBUSTION. Model HDR - RF. Manual Addendum. (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners
W 8ST R COMBUSTION A Selas Heat Technology Company Model HDR - RF Manual Addendum (To be used in conjunctin with HORS-RF Manual) For Gas, Oil and Combination burners With and without Low NOx Flue Gas Recirculation
More informationPROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.
PROFIRE D Series burners 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Cleaver-Brooks offers complete boiler
More informationRIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS
The Riello 40 FS series of one stage gas burners, is a complete range of products developed to respond to any request for light industrial application. The Riello 40 FS series is available in five different
More information1070 SERIES ULTRA LOW NO X
CAPABILITIES High release rates with moderate air Good turndown with flame characteristics and direction maintained Stable flames can be from highly oxidizing for tempered flame operation to highly reducing
More informationFeatures Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design
97311 The S&J 97311 Enclosed burner incinerates harmful emissions from waste gas streams. Typical applications include fermentation off gas piping systems such as anaerobic digesters or landfill gas. This
More informationproduct WM 20 for oil, gas and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on oil, gas and dual-fuel burners
product Information on oil, gas and dual-fuel burners WM 20 for oil, gas and dual-fuel WM 20 monarch burners (150 2600 kw) compact and powerful Progress and tradition: The latest monarch burner The monarch
More informationLP BURNER SERIES.
LP BURNER SERIES The Limpsfield LP burner series is characterised by a monoblock structure meaning all necessary components can be combined into a single unit, making installation and set-up easier and
More informationHEAVY DUTY RANGES GRIDDLE TOP
GRIDDLE TOP Model Numbers IHR-G36 IHR-GT36 IHR-G36-C IHR-GT36-C IHR-G36-XB IHR-GT36-XB IHR-G36-M IHR-GT36-M 1" (25 mm) thick steel polished griddle plate. M shaped burner for even heating throughout the
More informationproduct WM 20 for gas, oil, and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on gas, oil, and dual-fuel burners
product Information on gas, oil, and dual-fuel burners WM 20 for gas, oil, and dual-fuel WM 20 monarch burners (150 2600 kw) compact and powerful Progress and tradition: The latest monarch burner The monarch
More informationAPD14. Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF
APD14 Packaged Dual-Fuel Units Up to 14.5 SEER 81% AFUE / 8.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 6 Expanded Heating Data... 20 Airflow Data... 22 Dimensions...
More information97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel
97311T Designed for complete automatic operation of the entire Burner System, the S&J 97311T Enclosed Flare and Touch Screen Control Panel is specifically designed to operate efficiently with low BTU anaerobic
More informationOil, Gas and Dual Fuel Monoblock Burners
Capacity Oil, Gas and Dual Fuel Monoblock Burners 1-133 kw 1 Low Emission Combustion Technology Table of contents 2 Oilon Burners 8 Choosing the burner 9 NOx emissions 1 FGR - Flue Gas Recirculation 11
More informationXC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace
TUHM Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace XC 95m TUHMB060ACV3VA, TDHMB060BCV3VA TUHMB080ACV3VA, TDHMB080ACV3VA
More information... Cabinet Heaters Gas & Oil Fired Heaters ... ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant
abinet eaters as & Oil ired eaters rp 2018 rp Lot 21 Seasonal fficiency and NOx compliant abinet eaters... abinet heaters combine innovative design with a proven four pass heat exchanger technology to
More informationVALUPAK. Packaged gas burners
VALUPAK Packaged gas burners Low Temperature Burners - VALUPAK 1-1.5-1 High turndown. Available in 6 sizes. Capacities: 2 kw -1124 kw (HHV). Stable and clean combustion. Suitable for UV scanner and flame
More informationac-500 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven
ac-00 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven REPLACEMENT PARTS LIST Effective june, 0 Superseding All Previous Parts Lists. The Company reserves the right to make
More informationRetrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen
Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung Dr.-Ing. Marco Derksen Contents NOx formation In-furnace NOx reducing measures Application of premixed combustion Experiences in
More informationEiUK. Multi-Purpose Flue Gas Analyser. Service is what matters to most of us! Only 2 days turnaround
EiUK Multi-Purpose Flue Gas Analyser Check all combustion parameters Measure Differential Temperature Measure Differential Pressure Perform let-by, stabilization and tightness tests Perform CO build-up
More informationPower Plant and Process Burners
Power Plant and Process Burners Group 6 Capacity 6,800-273,000 MMBtu/h Power plants District heating plants Pulp and paper Chemical industry Metallurgic processes Municipal waste incineration Odorous gas
More informationLOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw
LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES 1/19 5 kw 35/4 91 kw 5/75 19 kw 11/14 4 kw The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed
More informationDVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG
Page: 2 of 10 Report No. R e p o r t Contents: Page Test model 3 Applicable examinations 3 Explanations / characteristics 3 Countries / categories / inlet pressures 4 Technical data 5 Execution variants
More informationFORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1
FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential
More informationAC-500 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST
AC-00 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL 9, 0 Superseding All Previous Parts Lists. The Company reserves the right to
More informationGREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER
TECHNICAL MANUAL GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER GREENOx/GREENOx.e/K WITH THREE GAS PASSES DUAL GRX/DUAL GRX.e THREE GAS
More informationTightness control TC. Product brochure GB Edition 12.10
Tightness control TC Product brochure GB 3.1.5. Edition 1.10 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted
More informationECONOMATIC REX/REXF REX/REXF DUAL STR
TECHNICAL MANUAL ECONOMATIC REX/REXF REX/REXF DUAL STR PRESSURISED STEEL BOILERS 96R WALTON ROAD, EAST MOLESEY, SURREY, KT8 0DL Tel. 08707 707 747 Fax. 08707 707 767 info@stokvisboilers.com - www.stokvisboilers.com
More informationTZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.
FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark
More informationRIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw
The Riello 40 GS series of one stage gas burners, is a complete range of products developed to respond to any request for home heating. The Riello 40 GS series is available in four different models, with
More informationOIL FIRED FURNACE REPLACEMENT PARTS MANUAL FLF085D36C FLF110D48C. Models: Contents. General Notes. Important
REPLACEMENT PARTS MANUAL OIL FIRED FURNACE Models: General Notes Contents Revised and/or additional pages may be issued from time to time. A complete and current manual consists of pages shown in the following
More informationPERM injection system Development. PERM injection system Validation
PERM injection system Development AVIO, Antonio Peschiulli KIT, Nikos Zarzalis PERM injection system Validation ENGINSOFT, Lorenzo Bucchieri ONERA, Isabel Da Costa DGA, Vincent Plana Index 1. Introduction
More informationOil - kerosene burner
Installation, use and maintenance instructions Oil - kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 9038 () TECHNICAL FEATURES Thermal power output 8 0 kw.3 5 kg/h Fuel Gas oil 35s,
More informationXC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace
TUHM Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace XC 95m TUHMB060ACV3VB, TDHMB060BCV3VB TUHMB080ACV3VB, TDHMB080ACV3VB
More informationUpflow, Upflow / Horizontal, Counterflow / Horizontal
Upflow, Upflow / Horizontal, Counterflow / Horizontal CG80 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long
More informationSpare parts list SI RSF 22/04/
Spare parts list 6720620020 25SI RSF 22/04/2009 6720620020 1 22/04/2009 6720620020 2 22/04/2009 6720620020 3 Spare parts list 1 Pump / Hydraulic assy 22/04/2009 6720620020 4 Pos description S-Nr ordering
More informationW801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )
FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features
More informationPRODUCT RANGE
PRODUCT RANGE 2018 www.ecoflam-burners.com CUSTOMIZED BURNERS SOLUTIONS FOR ANY TYPE OF APPLICATION OUR EXPERIENCE Thanks to 45 years of experience in the design and production of burners, Ecoflam offers
More informationSan Joaquin Valley Unified Air Pollution Control District
Best Available Control Technology (BACT) Guideline 2.1.1* Last Update 3/17/1997 Soil Remediation Operation - Thermal Oxidizer NOx 1. Natural gas with low NOx burner 2. Water injection (valid only for vapor
More informationPARTS LIST PRESSURELESS COOKER MODELS: GSX-5HE, GSX-7HE, GSX-10HE
PARTS LIST PRESSURELESS COOKER MODELS: 5HE, 7HE, 10HE CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, M3N 1V9 TELEPHONE: (416) 746-2358, FAX: (416) 746-8324 PRINTED IN
More informationXV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE
UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB TUD2B080A9V3VB TUD2C080A9V4VB TUD2C080B9V4VB TUD2B00A9V3VB TUD2C00A9V5VB TUD2C00B9V5VB TUD2DA9V5VB TUD2DB9V5VB TUD2DA9V5VB
More informationVAILLANT SPARE PART CATALOGUE TURBOmax boilers VU 182 E, 242 E, 282 E TURBOmax combination boilers TURBOmax VUW 242 E, 282 E 8026 74 GB 09/96 View of appliances VU 182, 242, 282 E VUW 242, 282 E Content
More informationVAILLANT SPARE PART CATALOGUE
VAILLANT SPARE PART CATALOGUE TURBOmax boilers VU 182 E, 242 E, 282 E TURBOmax combination boilers TURBOmax VUW 242 E, 282 E 8026 74 GB 09/96 View of appliances VU 182, 242, 282 E VUW 242, 282 E Content
More informationHamilton 3VO Submittal
Job RESET FORM Engineer Hamilton 3VO Submittal BOILER s H3H 750 WATER HEATER s H3D 750 Contractor Prepared By Date Input 100% factory fire tested Efficiency: up to 99.8% (based on incoming water) Maximum
More informationWeishaupt oil burners Sizes 30 to 70 1/2003 CA
Weishaupt oil burners Sizes 0 to 70 1/00 CA Description Weishaupt burners of sizes 0 to 70 were specially designed and developed for industrial applications. The Monoblock-Burners are characterized with
More informationTRUCK CRANE TG-500M JAPANESE SPECIFICATIONS NISSAN DIESEL KC-KG530TN TG-500M MITSUBISHI KC-KS509S TG-500M Control No.
TRUCK CRANE TG-500M JAPANESE SPECIFICATIONS TG CARRIER MODEL NISSAN DIESEL KC-KG530TN MITSUBISHI KC-KS509S SPEC. NO. TG-500M-5-10101 Control No. JA-01-209 - Return to INDEX TG-500M CRANE SPECIFICATIONS
More informationproduct WM 30 for gas, oil, and dual-fuel WM 30 monarch burners ( kw) powerful and versatile Information on gas, oil, and dual-fuel burners
product Information on gas, oil, and dual-fuel burners WM 30 for gas, oil, and dual-fuel WM 30 monarch burners (350 6200 kw) powerful and versatile Progress and tradition: The latest monarch burner The
More informationKINEMAX. Medium velocity gas or oil burners
KINEMAX Medium velocity gas or oil burners High Temperature Burners - KINEMAX -.- Exit velocities up to 00 km/h (8 m/s) to promote workload heat penetration and better furnace temperature uniformity Operate
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationDB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00
Technical Data Leaflet Industrial TS0086UK00 DB Series Industrial Dual Block Oil, Gas and Dual Fuel Burners DB 4 1000/2500 5000 kw DB 6 1400/4000 7800 kw DB 9 1500/5000 9500 kw DB 12 1700/7000 12500 kw
More informationZEECO BURNER DIVISION
ZEECO BURNER DIVISION Enhanced Jet Flat Flame Burners GLSF Series 22151 EAST 91ST STREET BROKEN ARROW OK 74014 USA +1-918-258-8551 SALES@ZEECO.COM ZEECO.COM INTRODUCTION: This document discusses the advantages
More informationData 330-3 9/15/07 Eclipse ImmersoJet Burners Model 3 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 6" w.c. Packaged (60Hz) 10" w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr)
More informationPackaged Gas/Electric. Cooling Capacity: 23,000 57,500 BTU/h
APG4M Packaged Gas/Electric 4 SEER / 8% AFUE ooling apacity:,000 57,500 BTU/h Heating apacity: 40,000 0,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling Data... 7 Airflow Data...
More informationCombination controls CG 10
Combination controls CG 0... Edition 03. GB Combination controls CG 0 Complete with strainer, two solenoid valves and servo-governor for maximum regulation precision. Special low-noise valves. Optional
More informationRheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace
Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace R802V- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization
More information4aIor. Repair Parts List. Valor Model 534/535 Gas Fireplace Heater. Radiant Gas Fireplaces 0B521-02
Valor Model 534/535 Gas Fireplace Heater Repair Parts List 4aIor Radiant Gas Fireplaces Manufactured by MILES INDUSTRIES LTD. Bitih Columbia. C anada 0B521-02 Manufactured by Miles Industries Ltd., British
More informationRS SERIES. Two Stage Progressive Gas Burners FIRING RATES
The RS burners series covers a firing range from 44 to 2290 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More information1500 SERIES LARGE CAPACITY ULTRA 2 LOW NO X
1500 SERIES LRGE CPCITY ULTR 2 LOW NO X URNER CPILITIES High release rates with moderate air pressure Good turndown with flame characteristics and direction maintained Stable flames can range from highly
More informationCapacities and Operating Data
CROSSFIRE Line Burner Page 5603 Capacities and Operating Data Performance Data Lineal heat release at high fire Minimum lineal heat release Btu/hr/f t 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000
More informationREX/REX F/REX K/REX K F REX DUAL/REX DUAL F
TECHNICAL MANUAL REX/REX F/REX K/REX K F REX DUAL/REX DUAL F PRESSURISED STEEL BOILERS INDEX 1 GENERAL WARNINGS... 4 2 TECHNICAL SPECIFICATIONS... 5 2.1 REX/REX K/REX F/REX K F 7-130 BOILER... 5 2.2 REX/REX
More informationMP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)
MP GS/GD Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 36-7745 http://www.garland-group.com Page 2 Moisture + MP-GS/GD DESCRIPTION PAGE Deluxe Control Panel 4 Standard
More informationRIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw
The Riello 40 F series of one stage light oil burners, is a complete range of products developed to respond to any request for light industrial applications. The Riello 40 F series is available in three
More informationRuud Achiever Plus Series Upflow/Horizontal Gas Furnace
Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More informationDP14GM. Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons. Cooling Capacity: 23,000 57,500 BTU/h Heating Capacity: 40, ,000 BTU/h
DP14GM ooling apacity: 23,000 57,500 BTU/h Heating apacity: 40,000 120,000 BTU/h Packaged Gas / Electric 14 SEER / 81% AFUE 2 to 5 Tons ontents Nomenclature... 2 Accessories... 2 Product Specifications...
More informationRheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace
Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-100 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated
More informationHigh-quality UV-resistant powder-paint finish aluminized steel tubular heat exchanger
GPG14M ooling apacity: 23,000 to 57,500 BTU/h Heating apacity: 40,000 to 120,000 BTU/h Packaged Gas / Electric Units 2 to 5 Tons 14 SEER / 81% AFUE ontents Nomenclature... 2 Product Specifications... 3
More informationRheem Classic Plus Series Upflow/Horizontal Gas Furnace
Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance
More information