Food Service Technology Center
|
|
- Lester Parker
- 5 years ago
- Views:
Transcription
1 Food Service Technology Center Piper NAEB102 Electric Combination Oven Test Report Application of ASTM Standard Test Method F November 2015 Prepared by: Michael Slater Fisher-Nickel, Inc. Prepared for: Pacific Gas and Electric Company Customer Energy Efficiency Programs PO Box San Francisco, California Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. 2015
2 Food Service Technology Center Background The information in this report is based on data generated at the Pacific Gas and Electric Company (PG&E) Food Service Technology Center (FSTC). Dedicated to the advancement of the foodservice industry, The FSTC has focused on the development of standard test methods for commercial foodservice equipment since The primary component of the FSTC is a 10,000 square-foot laboratory equipped with energy monitoring and data acquisition hardware, 60 linear feet of canopy exhaust hoods integrated with utility distribution systems, equipment setup and storage areas, and a state-of-the-art demonstration and training facility. The FSTC Energy Efficiency for Foodservice Program is funded by California utility customers and administered by PG&E under the auspices of the California Public Utilities Commission (CPUC). California customers are not obligated to purchase any additional services offered by the contractor. Policy on the Use of Food Service Technology Center Test Results and Other Related Information Fisher-Nickel, Inc. and the FSTC do not endorse particular products or services from any specific manufacturer or service provider. The FSTC is strongly committed to testing foodservice equipment using the best available scientific techniques and instrumentation. The FSTC is neutral as to fuel and energy source. It does not, in any way, encourage or promote the use of any fuel or energy source nor does it endorse any of the equipment tested at the FSTC. FSTC test results are made available to the general public through technical research reports and publications and are protected under U.S. and international copyright laws. Disclaimer Copyright 2015 Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. Reproduction or distribution of the whole or any part of the contents of this document without written permission of FSTC is prohibited. Results relate only to the item(s) tested. Neither, Fisher- Nickel, Inc., PG&E nor any of their employees, or the FSTC, make any warranty, expressed or implied, or assume any legal liability of responsibility for the accuracy, completeness, or usefulness of any data, information, method, product or process disclosed in this document, or represents that its use will not infringe any privately-owned rights, including but not limited to, patents, trademarks, or copyrights. Reference to specific products or manufacturers is not an endorsement of that product or manufacturer by Fisher-Nickel, Inc., the FSTC, or PG&E. In no event will Fisher-Nickel, Inc. or PG&E be liable for any special, incidental, consequential, indirect, or similar damages, including but not limited to lost profits, lost market share, lost savings, lost data, increased cost of production, or any other damages arising out of the use of the data or the interpretation of the data presented in this report. Retention of this consulting firm by PG&E to develop this report does not constitute endorsement by PG&E for any work performed other than that specified in the scope of this project. Legal Notice This report was prepared as a result of work sponsored by the California Public Utilities Commission (CPUC). It does not necessarily represent the views of the CPUC, its employees, or the State of California. The CPUC, the State of California, its employees, contractors, and subcontractors make no warranty, express or implied, and assume no legal liability for the information in this report; nor does any party represent that the use of this information will not infringe upon privately owned rights. This report has not been approved or disapproved by the CPUC nor has the CPUC passed upon the accuracy or adequacy of the information in this report. Revision History Revision num. Date Description Author(s) 0 Aug 2015 Initial Release M. Slater 1 Nov 2015 Corrected Idle Cavity Temperature Values M. Slater Page 2 of 16
3 Contents Equipment Description. 4 Test Location 4 Ventilation. 4 Test Instrumentation Inventory.. 5 FSTC Test Report: Results.. 6 Additions, Deviations, and Exclusions 9 ENERGY STAR Qualification.. 10 Manufacturer Specifications Sheet Report Certification.. 15 Page Page 3 of 16
4 Equipment Description Test Work Order Number (TWO) Manufacturer Piper Model Serial Number Generic Equipment Type Rated Input Construction Controls NAEB102 LA Combination Oven kw IPX5 protection against sprays of water; Smooth, watertight chamber; Door with double tempered glass with air chamber and interior heat-reflecting glass; Door handle; Adjustable hinge; Deflector for fan compartment cleaning; Stainless Steel body Touchscreen Interface External Dimensions (W x D x H) 46.06" x 35.24" x 40.95" Custom Settings (if any) Test Capacity None Cavity Dimensions (W x D x H) 27" x 31" x 30" 20 Full-Size (12" x 20" x 2.5") or (12" x 20" x 1") Steam Table Pans Test Location All testing was performed under controlled conditions in the FSTC laboratory facilities at Alcosta Blvd., Suite 101, San Ramon, CA Ventilation FSTC researchers installed the equipment on a tiled floor under a four-foot-deep canopy hood, which operated at a nominal exhaust rate of 300 cfm per linear foot. The hood was mounted six feet, six inches above the floor, with at least six inches of clearance between the vertical plane of the equipment and the hood s edge. Page 4 of 16
5 Test Instrumentation Inventory Description (ID) Manufacturer Model Measurement Range Resolution Calibration Date Next Calibration Digital Scale (ALB208) Mettler Toledo SB lb lb 12/17/ /17/2016 Electric Meter(ALD401) Electro Industries Shark A 15 Wh 11/17/ /17/2015 Water Meter (ALC313) Seametrics SEB gpm gal 09/16/ /16/2015 DAQ Temp (ALD414) National Instruments FP-TC F 0.1 F 08/12/ /12/2016 DAQ Pulse (ALD414) National Instruments FP-CTR ,000 pulses/s 1 pulse 08/12/ /12/2016 Page 5 of 16
6 CMBO CRT FSTC Test Report: Results Purpose of Testing This testing determined the energy input rate, preheat time and energy, idle energy rate, heavy-load cooking efficiency and production capacity in convection and steam modes by applying the ASTM Standard Test Method F Cavity Volume Internal Oven-Cavity Volume (CuFt) Piper Naboo 102 Combi Energy Input Rate Voltage (V) 208 Rated Energy Input Rate (kw) Measured Energy Input Rate (kw) Difference (%) 3.04 Preheat and Idle Steam Convection Preheat Ambient Temperature ( F) Final Preheat Temperature ( F) Duration (min) Test Voltage (V) Electric Energy Consumption (kwh) Preheat Rate ( F/min) Water Consumption (gal) Idle Ambient Temperature ( F) Test Voltage (V) Idle Energy Rate (kw) Average Cavity Temperature ( F) Water Consumption Rate (gal/h) Nameplate Information: Heavy-Load Cooking Energy Efficiency Steam Convection Ambient Temperature ( F) Food Product Red Potatoes Russet Potatoes Cavity Temperature ( F) Cook Time (min) Water Consumption Rate (gal/h) Test Voltage (V) Electric Energy Rate (kw) Energy to Food (Btu/lb) Piper Energy to Equipment (Btu/lb) S. 84th Avenue Cooking-Energy Efficiency (%) 65.1 ± ± 2.2 Wausau, WI Production Capacity (lb/h) ± ± *Based on a minimum of three test replicates Page 6 of 16
7 CMBO CRT FSTC Test Report: Results Preheat and Idle - Combi Mode Preheat Ambient Temperature ( F) 73.3 Final Preheat Temperature ( F) 341 Duration (min) 7.12 Test Voltage (V) 208 Electric Energy Consumption (kwh) 2.31 Preheat Rate ( F/min) 37.5 Water Consumption (gal) 27.5 Idle Ambient Temperature ( F) 74.8 Test Voltage (V) 208 Idle Energy Rate (kw) 2.80 Average Cavity Temperature ( F) 351 Water Consumption Rate (gal/h) 17.2 Steam Heavy-Load Red Potato (Perforated Deep Full-size Pans) Test Data Measured Values Test #1 Test #2 Test #3 Test Date 6/23/15 6/26/15 6/29/15 Ambient Temperature ( F) Number of Pans Total Potato Count Initial Weight of Potatoes (lb) Final Weight of Potatoes (lb) Initial Temperature of Potatoes ( F) Final Temperature of Potatoes ( F) Weight of Steam Table Pans (lb) Test Time (min) Test Voltage (V) Electric Energy Consumption (kwh) Gas Energy Consumption (Btu) N/A N/A N/A Gas Heating Value (Btu/scf) N/A N/A N/A Water Consumption (gal) Calculated Values Specific Heat of Potatoes (Btu/lb,F) Sensible Energy (Btu) 16,989 16,952 16,987 Total Energy to Food (Btu) 16,989 16,952 16,987 Energy to Food (Btu/lb) Energy to Pans (Btu) Total Equipment Energy Consumption (Btu) 28,430 26,621 26,519 Energy to Equipment (Btu/lb) Results Cooking Energy Efficiency (%) Test Voltage (V) Electric Energy Rate (kw) Production Capacity (lb/h) Cook Time (min) Water Consumption Rate (gal/h) Page 7 of 16
8 CMBO CRT Convection Heavy-Load Cooking Russet Potato (Perforated Shallow Full-size pans) Test Data Measured Values Test #1 Test #2 Test #3 Test Date 6/24/15 6/25/15 6/26/15 Ambient Temperature ( F) Number of Pans Total Potato Count Initial Weight of Potatoes (lb) Final Weight of Potatoes (lb) Initial Temperature of Potatoes ( F) Final Temperature of Potatoes ( F) Weight of Steam Table Pans (lb) Test Time (min) Test Voltage (V) Electric Energy Consumption (kwh) Gas Energy Consumption (Btu) N/A N/A N/A Gas Heating Value (Btu/scf) N/A N/A N/A Water Consumption (gal) Calculated Values Specific Heat of Potatoes (Btu/lb,F) Sensible Energy (Btu) 15,990 15,990 16,028 Latent Vaporization Energy (Btu) 15,882 15,882 16,212 Total Energy to Food (Btu) 31,872 31,872 32,239 Energy to Food (Btu/lb) Energy to Pans (Btu) Total Equipment Energy Consumption (Btu) 39,625 39,164 39,215 Energy to Equipment (Btu/lb) Results Cooking Energy Efficiency (%) Test Voltage (V) Electric Cooking Energy Rate (kw) Production Capacity (lb/h) Cook Time (min) Water Consumption Rate (gal/h) Cooking Energy Efficiency Uncertainty Results Steam Convection Average (%) Standard Deviation Absolute Uncertainty (%) % Uncertainty Production Capacity Uncertainty Results Steam Convection Average (lb/h) Standard Deviation Absolute Uncertainty (lb/h) % Uncertainty Page 8 of 16
9 CMBO CRT Additions, Deviations, and Exclusions Additions: None Deviations: None Exclusions: The combination mode ice load cooking uniformity test, as specified in section 10.8 of ASTM F , was not performed. Page 9 of 16
10 ENERGY STAR Qualification FSTC testing of the Piper NAEB102 electric combination oven resulted in an idle rate of 2.34 kw in steam mode and 1.88 kw in convection mode, and an energy efficiency of 65.1% in steam mode and 83.0% in convection mode. The results comply with the ENERGY STAR program requirement for commercial combination ovens version 2.1. Page 10 of 16
11 Manufacturer Specifications Sheet Page 11 of 16
12 Manufacturer Specifications Sheet (Continued) Page 12 of 16
13 Manufacturer Specifications Sheet (Continued) Page 13 of 16
14 Manufacturer Specifications Sheet (Continued) Page 14 of 16
15 Page 15 of 16
16
Food Service Technology Center
Food Service Technology Center Convotherm C4eT 6.20EB Electric Combination Oven Test Report Application of ASTM Standard Test Method F2861-10 May 2015 Prepared by: Denis Livchak Fisher-Nickel, Inc. Contributors:
More informationFood Service Technology Center
Food Service Technology Center Frymaster BIELA214-2RCSD Electric Fryer Test Report Application of ASTM Standard Test Method F1361-07 September 2016 Prepared by: Edward Ruan Fisher-Nickel, Inc. Contributors:
More informationFood Service Technology Center
Food Service Technology Center Sapidus H2Oil UE-1100 (240V) Electric Fryer Test Report Application of ASTM Standard Test Method F1367-07 November 2015 Prepared by: Edward Ruan Fisher-Nickel, Inc. Contributors:
More informationFood Service Technology Center
Food Service Technology Center Baxter OV500G1-EE Gas Single Rack Oven Test Report Application of ASTM Standard Test Method F2093-11 March 2014 Prepared by: Michael Karsz Fisher-Nickel, Inc. Prepared for:
More informationFood Service Technology Center
Food Service Technology Center Giles GGF-400 Gas Fry Kettle FSTC Report # 501311131-R0 Application of ASTM Standard Test Methods F1964-11, 1361-07 December 2012 Prepared by: Adam Cornelius Denis Livchak
More informationScope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems
Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for
More informationVulcan, VPX5 Electric Steamer Performance Test
Vulcan, VPX5 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.02 Food Service Technology Center Final Report, May 2001 Prepared by: Todd Bell Fisher-Nickel
More informationMarket Forge, ET-5E Electric Steamer Performance Test
Market Forge, ET-5E Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.98 Food Service Technology Center Final Report, April 2001 Prepared by: Todd
More informationVulcan, VPX3 Electric Steamer Performance Test
Vulcan, VPX3 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.01 Food Service Technology Center Final Report, May 2001 Prepared by: Todd Bell Fisher-Nickel
More informationCleveland Range Inc., SteamCraft Ultra 3 Electric Steamer Performance Test
Cleveland Range Inc., SteamCraft Ultra 3 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.00.84 Food Service Technology Center Final Report, November
More informationMarket Forge, ET-3E Electric Steamer Performance Test
Market Forge, ET-3E Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.99 Food Service Technology Center Final Report, April 2001 Prepared by: Todd
More informationSpring Air Systems FN-B-MB-10/4.5-VE Wall-Mounted Canopy Exhaust Hood Performance Report
Spring Air Systems FN-B-MB-10/4.5-VE Wall-Mounted Canopy Exhaust Hood Performance Report Application of ASTM Standard Test Method F1704-09 FSTC Report 501311275 Food Service Technology Center Prepared
More informationVulcan-Hart Gas Steamer Performance Testing Model VHX24G-3
Vulcan-Hart Gas Steamer Performance Testing Model VHX24G-3 Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.01.97 Food Service Technology Center Final Report, February 2001 Prepared
More informationCommercial Food Service Equipment Specifications for California Investor-Owned Utility-Based Incentives 2015
Commercial Foodservice Appliance Qualification Requirements for the California Energy Wise Program: Any Commercial cooking appliances must have a representative model tested and verified by a California
More informationWatlow Model Firebar 1000 and 1600 Prototype Element Performance Test
Watlow Model Firebar 1000 and 1600 Prototype Element Performance Test In a standard fryer In accordance with ASTM Standard Test Method F 1361-95 FSTC Report 5011.98.60 Food Service Technology Center Manager:
More informationThermal Engineering Corporation (TEC ) Searmaster II, Model SM2103 Underfired Broiler Performance Test
Thermal Engineering Corporation (TEC ) Searmaster II, Model SM2103 Underfired Broiler Performance Test Application of ASTM Standard Test Method F 1695-03 FSTC Report 501310104 March 2011 Prepared by: Greg
More information2013 Spring Calendar. be energy wise. California Utilities Partnering for Energy Efficiency. California Energy Wise Foodservice Seminars
California Utilities Partnering for Energy Efficiency 2013 Spring Calendar California Energy Wise Foodservice Seminars Energy-Efficient Equipment Demonstrations be energy wise Informative Educational Seminars
More informationGaylord 30-inch Tall ELX-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report
Gaylord 30-inch Tall ELX-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report Application of ASTM Standard Method F1704-09 FSTC Report 5011.09.06-R1 Food Service Technology Center Prepared by:
More informationAccuTemp STEAM n HOLD, Model 208-D8-300 Electric Steamer Performance Test
AccuTemp STEAM n HOLD, Model 208-D8-300 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.99.75 Food Service Technology Center Manager: Don Fisher Final
More informationScope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems
Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for
More informationGaylord Company, Model EL-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report
Gaylord Company, Model EL-ND-BDL-54 Wall-Mounted Canopy Exhaust Hood Performance Report Application of ASTM Standard Test Method F 1704-05 Food Service Technology Center (www.fishnick.com) -R1 Prepared
More informationVulcan-Hart Gas Steamer Performance Testing Model VL2GSS (Pressure) and Model VS3616G (Atmospheric)
Vulcan-Hart Gas Steamer Performance Testing Model VL2GSS (Pressure) and Model VS3616G (Atmospheric) Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.00.85 Food Service Technology Center
More informationAccuTemp, Model S3 Electric Steamer Performance Test
AccuTemp, Model S3 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-05 FSTC Report # 5011.05.08 April 2005 Prepared by: Chuck Wallace Victor Kong David Zabrowski Fisher-Nickel,
More informationAccuTemp STEAM N HOLD, Model 208-D Electric Steamer Performance Test
AccuTemp STEAM N HOLD, Model 208-D12-300 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report # 5011.03.02 (Revised) June 2003 Prepared by: Todd Bell David Zabrowski
More informationCOMMERCIAL FOOD SERVICE EQUIPMENT REBATE APPLICATION
COMMERCIAL FOOD SERVICE EQUIPMENT REBATE APPLICATION 1. CUSTOMER INFORMATION (please print) Account Name Doing Business As (if different from Account Name) Installation Address City State Zip Code Mailing
More informationScope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems
Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for
More informationGlendale Water & Power Smart Grid Project
Glendale Water & Power Smart Grid Project Key Dates in Project History Key Dates Project History On July 10, 2007, City Council directed GWP to develop a long term plan for smart meters On October 23,
More informationBorrego Springs Microgrid Demonstration Overview
Borrego Springs Microgrid Demonstration Overview Society of American Military Engineers San Diego, CA March 11, 2015 Neal Bartek Distributed Energy Resources Manager 2012 San Diego Gas & Electric Company.
More informationVulcan ER50D Electric Fryer Performance Tests
Vulcan ER50D Electric Fryer Performance Tests Application of ASTM Standard Test Method F 1361-07 FSTC Report 5011.08.04 December 2008 Prepared by: Greg Sorensen David Cowen David Zabrowski Fisher-Nickel,
More informationBuilding Blocks and Opportunities for Power Electronics Integration
Building Blocks and Opportunities for Power Electronics Integration Ralph S. Taylor APEC 2011 March 8, 2011 What's Driving Automotive Power Electronics? Across the globe, vehicle manufacturers are committing
More informationELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL
ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL 30119-03 Rev. 4.8 April, 2013 TABLE OF CONTENTS Section Page 1. INTRODUCTION...1 1.1 Description...1 1.2 Uncrating...1 1.3 Serial
More informationModel SSKR Automate Vehicle Anti-Theft System
Model SSKR Automate Vehicle Anti-Theft System Owner s Guide limited lifetime consumer warranty Directed Electronics, Inc. promises to the original purchaser to repair or replace with a comparable reconditioned
More informationPerformance Rating of Airto-Air Heat Exchangers for Energy Recovery Ventilation Equipment
AHRI Standard 1060 (I-P) 2011 Standard for Performance Rating of Airto-Air Heat Exchangers for Energy Recovery Ventilation Equipment IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 FOOD SERVICE TECHNOLOGY CENTER 12949 Alcosta Blvd Suite 101 San Ramon, CA 94583 Richard Swierczyna Phone: 925-866-2844 Email: rswierczyna@fishnick.com MECHANICAL
More informationToro Sprayer Calibration Tool
Commercial Products Toro Sprayer Calibration Tool User Guide & Installation Instructions Toro Sprayer Calibration Tool 1 Table of Contents Introduction... 2 Program Instructions... 4 Toro Software End
More informationFrymaster Protector Gas Fryer Performance Tests
Frymaster Protector Gas Fryer Performance Tests Application of ASTM Standard Test Method F 1361-05 FSTC Report 5011.08.03 February 2008 Prepared by: Greg Sorensen David Cowen David Zabrowski Fisher-Nickel,
More informationPVI 60KW, PVI 82KW, PVI 95KW
PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy
More informationPVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables
PVI 1800/PVI 2500 WARRANTY MANUAL Residential/Commercial Grid-Tied Photovoltaic Inverter 2009, Solectria Renewables Subject to Change REV 10.09 1 Product Warranty & RMA Policy 1.1 Warranty Policy The Solectria
More informationUser's Manual. Model Hot Wire Thermo-Anemometer. Introduction
User's Manual Model 407123 Hot Wire Thermo-Anemometer Introduction Congratulations on your purchase of Extech s Hot Wire Anemometer. This meter is equipped with a telescoping antenna, indicates air-flow
More informationTANK RISER SUSPENSION SYSTEM CONCEPTUAL DESIGN (U)
Revision 0 TANK RISER SUSPENSION SYSTEM CONCEPTUAL DESIGN (U) R. F. Fogle September 15, 2002 Westinghouse Savannah River Company LLC Savannah River Site Aiken, South Carolina 29802 This document was prepared
More informationGM Specification Annual Test Data
GM Specification Annual Test Data GM Specification Annual Test Data Technical Bulletin The 3M IATD Quality Laboratory tested the following tapes to the Automotive Specification. The results of the testing
More informationWARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN
WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter
More informationModel D Spray Gun. Parts Identification Manual 2943J-ID. "Success through Unity" June 17, 2003 Issue 2 GUSMER CORPORATION
"Success through Unity" Model D Spray Gun Parts Identification Manual 2943J-ID June 17, 2003 Issue 2 GUSMER CORPORATION A Subsidiary of Gusmer Machinery Group, Inc. One Gusmer Drive Lakewood, New Jersey,
More informationFrymaster 22 kw Protector Electric Fryer Performance Tests
Frymaster 22 kw Protector Electric Fryer Performance Tests Application of ASTM Standard Test Method F 1361-05 FSTC Report 5011.08.11 May 2008 Prepared by: David Cowen David Zabrowski Fisher-Nickel, Inc.
More informationProject Title: Contract Number: Milestone Number: Report Date: Contract Contact: Phone: Congressional District: Executive Summary:
Project Title: 350 kw Target Midway Solar PV Project Contract Number: EP4-20 Milestone Number: 1 Report Date: 12/28/2016 Contract Contact: Brittany Stanton Phone: 612-696-0823 Congressional District: MN
More informationLSI SAS e HBA Temperature and Airflow
LSI SAS 9206-16e HBA Temperature and Airflow Application Note Preliminary, Version 1.0 DB06-000784-00 Revision History Version and Date Preliminary, Version 1.0, Initial release of this document. Description
More informationA Member of the. Integrated Metering Technologies
I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe
More informationGM Specification Annual Test Data
GM Specification Annual Test Data GM Specification Annual Test Data Technical Bulletin The 3M IATD Quality Laboratory tested the following tapes to the Automotive Specification. The results of the testing
More informationHybrid Electric Vehicle End-of-Life Testing On Honda Insights, Honda Gen I Civics and Toyota Gen I Priuses
INL/EXT-06-01262 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Hybrid Electric Vehicle End-of-Life Testing On Honda Insights, Honda Gen I Civics and Toyota Gen I Priuses TECHNICAL
More informationDr. Chris Dudfield. Chief Technology Officer Intelligent Energy. Sponsors
Dr. Chris Dudfield Chief Technology Officer Intelligent Energy Sponsors 7 th September 2017 Creating the blueprint for advanced fuel cell manufacturing Dr Chris Dudfield Chief Technology Officer 2 The
More information3M Connector System 0.050" x 0.100" Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810
1 of 9 3M Connector System 0.050" x 0.100" Pitch 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810 Product Specification 78-5110-0074-0 Released: 10-1-10 2 of 9
More information3M Three-Wall and Four-Wall Headers. Series 3XXX
1 of 7 M Three-Wall and Four-Wall Headers Series XXX Product 78-10-0008-0 Released: 0-0-11 of 7 Table of Contents Section Page 1. Scope........ M Customer Documents....... Performance and Test Descriptions...
More informationLT-EL138 LED Flashlight
LT-EL138 LED Flashlight 1 2! CAUTION! If you need to mount the flashlight onto a firearm, make sure firearm is not loaded before installation. Remove magazine and examine chamber. Use safe handling procedures
More informationSacramento Municipal Utility District s EV Innovators Pilot
Sacramento Municipal Utility District s EV Innovators Pilot Lupe Jimenez November 20, 2013 Powering forward. Together. Agenda SMUD Snapshot Pilot Plan v Background v At-a-Glance v Pilot Schedule Treatment
More informationDigital Remote Wheels DRW-1
Digital Remote Wheels DRW-1 USER MANUAL Date 01.12.2018 2 Imprint Imprint Copyright 2018 Arnold & Richter Cine Technik GmbH & Co. Betriebs KG. All rights reserved. No parts of this document may be reproduced
More informationFood Service Equipment Application
Food Service Equipment Application July 1, 2013 - June 30, 2014 Customer Information Company Anticipated Installation Date (Approval required prior to installation) Electric Utility Serving Applicant Electric
More informationRECHARGE STATION OPERATION MANUAL. Version
RECHARGE STATION OPERATION MANUAL Version 1.0-0712 2014 by VirTra Inc. All Rights Reserved. VirTra, the VirTra logo are either registered trademarks or trademarks of VirTra in the United States and/or
More informationPanel Mount Digital Tachometer Model
User Guide Panel Mount Digital Tachometer Model 461950 Introduction Congratulations on your purchase of the Extech 461950 Panel Tachometer. This meter displays continuous readings from 5 to 99,990 rpm.
More informationProject Title: Lowertown Ballpark (CHS Field) Solar Arrays Contract Number: EP4-34 Milestone Number: 1 Report Date: June 21, 2016
DEPARTMENT OF PARKS AND RECREATION DESIGN AND CONSTRUCTION CITY OF SAINT PAUL Mayor Christopher B. Coleman 400 City Hall Annex 25 West 4 th Street Saint Paul, Minnesota 55102 www.stpaul.gov/parks Telephone:
More informationModel 700 Microarray Oven
www.scigene.com Model 700 Microarray Oven USER MANUAL Cat. #1070-00-1, 1070-00-2 FOR RESEARCH USE ONLY Not for Use in Diagnostic Procedures SciGene 306 Potrero Ave, Sunnyvale, CA 94085 USA 408-733-7337
More informationSANDAG Vanpool Program Guidelines as of February 2018
SANDAG Vanpool Program Guidelines as of February 2018 The San Diego Association of Governments (SANDAG) administers the SANDAG Vanpool Program to provide alternative transportation choices to commuters,
More informationNISSAN 370Z INTELLI-KEY Rev.:
Remote Starter NISSAN 70Z 009-00 INTELLI-KEY Rev.: 0096 009 Not included: x Fuse 5Amp x s Amp x Relays Override OEM Transponder Immobilizer Via Data (No Key Required). Interfaces directly with the latest
More informationLarge Diameter Steel Flanges
ASME B16.47-2011 (Revision of ASME B16.47-2006) Large Diameter Steel Flanges NPS 26 Through NPS 60 Metric/Inch Standard AN AMERICAN NATIONAL STANDARD ASME B16.47-2011 (Revision of ASME B16.47-2006) Large
More informationTest Rig Design for Large Supercritical CO 2 Turbine Seals
Test Rig Design for Large Supercritical CO 2 Turbine Seals Presented by: Aaron Rimpel Southwest Research Institute San Antonio, TX The 6th International Supercritical CO 2 Power Cycles Symposium March
More informationSSC Sensor Replacement Board for the SSC Evaluation Kit. Features. Benefits
SSC Sensor Replacement Board for the SSC Evaluation Kit ZSC31XXX / ZSSC3XXX Datasheet Brief Description The SSC Sensor Replacement Board is included in IDT s modular SSC Evaluation Kits, which provide
More informationUtilization of Associated Gas to Power Drilling Rigs A Demonstration in the Bakken
Utilization of Associated Gas to Power Drilling Rigs A Demonstration in the Bakken Bakken Artificial Lift and Production Denver, Colorado September 24 25, 2013 Chad Wocken*, John Harju, Grant Dunham, and
More information4lliedSig nal. Development of a Digital Control Unit to Displace Diesel Fuel With Natural Gas. Federal Manufacturing & Tech nolog ies. A. D.
Development of a Digital Control Unit to Displace Diesel Fuel With Natural Gas Federal Manufacturing & Tech nolog ies A. D. Talbott KCP-613-5913 I Published March 1997 Final ReporVProject Accomplishments
More informationAir Curtain. Installation, Operating and Maintenance Instructions
Installation, Operating and Maintenance Instructions Save this manual for future reference. Air Curtain Model Numbers: ES026, ES036, ES042, ES048, ES060, ES072 READ THIS OWNER S MANUAL CAREFULLY BEFORE
More informationModel GX Spray Gun
"Teamwork & Communication" Model GX-7-400 Spray Gun Parts Identification Manual 17943-ID May 24, 1999 Issue 2 GUSMER CORPORATION A Subsidiary of Gusmer Machinery Group, Inc. One Gusmer Drive Lakewood,
More informationTX21U Temperature/Humidity Sensor. Instruction Manual
TX21U Temperature/Humidity Sensor Instruction Manual TABLE OF CONTENTS Topic Page Inventory of Contents/Additional Equipment 2 Detailed Set-Up Guide Battery installation 3 Mounting 3 Maintenance & Care
More informationCBC-160-1N and CBC-160-2N Clutch/Brake Controls
P-239-36 819-04 CBC-160-1N and Clutch/Brake Controls Installation Instructions An Altra Industrial Motion Company Contents Introduction...2 Specifications........................... 2 Installation...3
More informationUser's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable
User's Guide Vane Anemometer Model 451112 Measures Air Velocity & Temperature Degrees C/F switchable 6 selectable units of measure Data Hold function Introduction Congratulations on your purchase of Extech
More informationElectron Positron Proton Spectrometer for use at Laboratory for Laser Energetics
LLNL-TR-427769 Electron Positron Proton Spectrometer for use at Laboratory for Laser Energetics S. L. Ayers April 13, 2010 Disclaimer This document was prepared as an account of work sponsored by an agency
More informationTOTALIZER-TRANSMITTER
TOTALIZER-TRANSMITTER MODEL TR04-2 OPERATION AND MAINTENANCE MANUAL PARTS LIST FEATURING: *SEALED HOUSING *STANDARD TOTALIZER ASSEMBLY *MAGNETICALLY ACTUATED REED SWITCH 3255 WEST STETSON AVENUE HEMET,
More informationMODERN GRID S T R A T E G Y
Smart Grid Concepts U.S. Commercial Service Webinar Joe Miller Modern Grid Strategy Team Lead September 16, 2009 Funded by the U.S. Department of Energy, Conducted by the National Energy Technology Laboratory
More information3M CP2 Press-Fit Headers and Sockets, 2 mm
1 of 7 3M CP2 Press-Fit Headers and Sockets, 2 mm A-Style CP2 Connectors CP2-SA110-G1-KR Right Angle Socket Connectors mated to CP2-HA110-GA1-KR Header Connectors 78-5102-0083-1 Revised Date: February
More informationNISSAN MAXIMA INTELLI-KEY Rev.:
Remote Starter NISSAN MAXIMA 2009-2011 INTELLI-KEY Rev.: 20091126 20110921 Not included: 1x Fuse 15Amp 3x s 3x Relays Override OEM Transponder Immobilizer Via Data (No Key Required). Interfaces directly
More informationBEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA
BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA Order Instituting Rulemaking Concerning Energy Efficiency Rolling Portfolios, Policies, Programs, Evaluation, and Related Issues. R.13-11-005
More informationWeb Volume Control Model WV220
WEB CONTROL PRODUCTS User Manual Web Volume Control Model WV220 1 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject
More informationEmergency Response Trailer 14
Emergency Response Trailer 14 User & Genave / NRC, Inc. www.genave.com support@genave.com Copyright 2017. Genave / NRC, Inc. Tech. Publication No. 9000-0000-115 Rev 01 Warning If incorrectly used, this
More informationMotor Mounting Kits. Instructions J EN. 16C487 Motor Coupler Kit includes 2.25 in. (57.2 mm) key For NEMA 182/184 TC Frame ATEX Electric Motors
Instructions Motor Mounting Kits 31160J EN To install electric motors on E-Flo 4-Ball Piston Pumps. For professional use only. (Kits do not include motors.) 16C487 Motor Coupler Kit includes 2.2 in. (7.2
More informationSmart-UPS RT External Battery Pack Stack/Rack-Mount 6U
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external
More informationMulti-Stage Selective Catalytic Reduction of NO in Lean-Burn Engine Exhaust. B. M. Penetrante M. C. Hsiao B. T. Merritt G. E.
UCRL-JC-128071 PREPRINT Multi-Stage Selective Catalytic Reduction of in Lean-Burn Engine Exhaust x B. M. Penetrante M. C. Hsiao B. T. Merritt G. E. Vogtlin This paper was prepared for submittal to the
More informationCity Title. . Is System Owner interested in being contacted about energy efficiency opportunities at this site? Title. City. Site Contact.
To be completed by Solar Electric Design Ally and Project Owner Don't Forget to Include Project Owner and Design Ally Signatures Site Layout Sun Chart Wiring Schematic Program Use Only FastTrack ID Project
More informationGas Turbine Aircraft Engines
ASME PTC 55-2013 Gas Turbine Aircraft Engines Performance Test Codes AN AMERICAN NATIONAL STANDARD ASME PTC 55-2013 Gas Turbine Aircraft Engines Performance Test Codes AN AMERICAN NATIONAL STANDARD Two
More informationXXXXX. Kokish River Hydroelectric Project. Interconnection Facilities Study and Project Plan
XXXXX Kokish River Hydroelectric Project Interconnection Facilities Study and Project Plan March 16, 2011 British Columbia Hydro and Power Authority British Columbia Hydro and Power Authority 2010. All
More informationRRI PERFORMANCE ASSESSMENT OF AFTERMARKET PERFORMANCE MODIFICATION 1 (12)
- Road Vehicles - Steady State Test Mode - - Powertrain Performance Comparison Test Code - Performance Assessment of Aftermarket Performance Modification - 1 (12) Status of Document Type Description Publication
More informationModel 8144NC Fresh Air Ventilator
Model 8144NC Fresh Air Ventilator Installation and Operating Instructions MOUNTING BRACKETS WIRE ENTRY LOCATION INTEGRAL PRESSURE PORTS (PORT ON INLET SIDE NOT SHOWN) OVAL OUTLET COLLAR FOR 6" DIAMETER
More informationThe Realities of Consumer-Owned Wind Power For Rural Electric Co-operatives
The Realities of Consumer-Owned Wind Power For Rural Electric Co-operatives Steve Lindenberg U.S. Department of Energy Jim Green National Renewable Energy Laboratory WINDPOWER 2006 Pittsburgh, June 4-8,
More informationModel 4003 Remote Start Owner s Guide
Model 4003 Remote Start Owner s Guide 2009 Directed Electronics, Vista, CA G4003L 2009-04 Contents Warning! Safety first...2 What is Included...4 Important Information...4 Your Warranty...4 Using Your
More informationBulletin 1494M Fixed Depth Remote Operated Disconnect Switches Renewal Parts
Page 1 of 8 Knowledgebase Technote ID # Q37160174 5/13/2005 Repair Parts for the Handle/Mechanism and Fusible Disconnect Switch Assembly (See Figure 1 on next page for exploded view of parts.) Catalog
More informationWARNING Read these materials prior to assembling and using the trampoline and Trampoline Enclosure
& Rectangular PowerBounce User s Manual Assembly, Installation, Care, Maintenance, and Use Instructions WARNING Read these materials prior to assembling and using the trampoline and Trampoline Enclosure
More informationUp to 3 W solar and USB battery charger for single-cell Li-Ion and Li-Po batteries based on the SPV1040, STBC21 and STC3100
Up to 3 W solar and USB battery charger for single-cell Li-Ion and Li-Po batteries based on the SPV1040, STBC21 and STC3100 Features Data brief Solar section Solar energy harvester with proprietary Perturb
More informationTERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)
TERMS OF USE 1. Watts pricing and product data is subject to change without notice and such changes supersede all previous versions. 2. Watts data is to be used as provided. Watts is not responsible for
More informationASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.
Instruction-Parts ASM Maxi Poles 312483B For the application of architectural paints and coatings. 3400 Series 4050 psi (27.92 MPa, 280 bar) Maximum Working Pressure Important Safety Instructions Read
More informationParts Manual. Spray Gun Series Master II. Issue /09/2017 Ref. NR ENG
Spray Gun Series Master II Issue 3.2 27/09/2017 Ref. NR-00020-ENG Before starting or carrying out maintenance work on the MASTER II gun, please carefully read all the technical and safety documentation
More informationDRVRMDMOTL Motorized Linear Drive. DRVMDMOTLR Motorized Linear and Rotary Drive. Instruction Manual
DRVRMDMOTL Motorized Linear Drive DRVMDMOTLR Motorized Linear and Rotary Drive Instruction Manual Version 1.1 07 November 2016 Thurgauerstr. 72, CH-8050 Zürich, Switzerland TEL. +41 44 273 16 38, FAX.
More informationREDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.
REDI-LINE ELECTRIC GENERATORS USER'S GUIDE Rugged, Reliable, DC to AC Power Conversion KARAM A.L. www.alternatorstarter.com 1-888-515-2726 REDI-LINE ELECTRIC GENERATOR MODEL INPUT ACTUAL OUTPUT ACTUAL
More informationSmart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual
Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX Owner s Manual Table of Contents Important Safety Instructions 2 Features 3 Installation Guidelines 5 Warranty 8 1.0 Important
More informationInstallation Instructions for: Channel Thermocouple Amplifier
Installation Instructions for: 30-2204 4 Channel Thermocouple Amplifier WARNING: This installation is not fo r the electrically or mechanically challenged! Use this sensor with EXTREME caution! If you
More information