EPA TIER 4 AND THE ELECTRIC POWER INDUSTRY. Tim Cresswell Tier 4 Product Definition Manager Electric Power Division

Size: px
Start display at page:

Download "EPA TIER 4 AND THE ELECTRIC POWER INDUSTRY. Tim Cresswell Tier 4 Product Definition Manager Electric Power Division"

Transcription

1 EPA TIER 4 AND THE ELECTRIC POWER INDUSTRY Tim Cresswell Tier 4 Product Definition Manager Electric Power Division March 2014

2 INTRODUCTION The initiative to lower diesel engine emissions started with on-highway engines in 1973 and now extends to non-road mobile equipment, marine and locomotive engines, and stationary engines. These lower standards present significant technical and operational challenges for both engine users and manufacturers. While stringent diesel engine emission standards generally result in cleaner air, the challenges will continue in the United States as the Environmental Protection Agency (EPA) and the California Air Resources Board (CARB) phase in even more stringent diesel engine emission limits. Since the introduction of non-road Tier 1 regulations in 1996, the EPA has lowered the limits on emissions from dieselpowered non-road mobile equipment, and manufacturers have responded by utilizing innovative technologies to achieve compliance. While the requirements to certify diesel engines generally shift the burden of air quality compliance toward manufacturers, end users must also be aware of local or sitespecific regulations affecting their operations. Such awareness can help end users make sound choices in choosing stationary and mobile generator sets for specific applications. UNDERSTANDING DIESEL ENGINE EMISSIONS RULES Today s drive toward improved air quality originates from the Clean Air Act of 1970, passed a few months after the first Earth Day. Since then, internal combustion engines have been a high priority for emissions reduction. First came automobiles; then, in 1973, on-highway trucks were identified. The Clean Air Act as amended in 1990 set air quality attainment standards for the entire nation. The focus was on specific Criteria Pollutants: NOx, carbon monoxide, sulfur dioxide, ozone, lead and particulate matter. The EPA designated areas not meeting national ambient air quality standards (or NAAQS) for any of these pollutants as nonattainment areas. Emissions regulations in nonattainment areas, usually set by state government or local air quality boards, can be far more strict than broad national standards issued by the EPA. In 1994, the EPA began an aggressive, long-term effort to reduce emissions from new non-road mobile diesel engines. This affected new mobile equipment like construction machines and agricultural tractors, as well as industrial equipment, such as diesel-powered generator sets used in mobile electric power generation. It was during this time that the EPA adopted the first set of emission standards (Tier 1) for all new non-road mobile diesel engines of all horsepower categories, except those used in locomotives and marine vessels. These non-road mobile regulations were phased in by engine horsepower range between 1996 and 2000, reducing NOx emissions by approximately 30 percent from Tier 0 levels. In 1998, the EPA adopted more stringent Tier 2 emission standards for NOx, unburned hydrocarbons, carbon monoxide and particulate matter emitted from new non-road mobile diesel engines. These stricter Tier 2 emission standards were phased in from 2001 to 2006 for all engine sizes. Tier 3 standards, which lowered diesel exhaust emissions below Tier 2 levels for engines from 37 to 560 bkw (50 to 750 bhp), were implemented during the 2005/2006 to 2008 time period. The Clean Air Act also provided an exemption for the State of California allowing them to set their own non-road mobile emissions limits as reviewed and approved by the U.S. EPA. These standards, set by the California Air Resources Board, or CARB, are generally more restrictive than U.S. EPA standards and are meant to address the significant state air quality issues in such locations as the Los Angeles basin and the San Joaquin valley. Other states may adopt, or opt into, the California standards as long as the EPA grants approval. Engine manufacturers must be aware of and plan for these special California standards in addition to the U.S. EPA standards. 2

3 Standards affecting stationary diesel engines Beginning January 1, 2007, new stationary diesel engines had to meet the EPA s Compression Ignition (CI) New Source Performance Standards (NSPS), which include diesel powered generator sets. The CI NSPS, for most engine horsepower ranges, incorporated the EPA non-road mobile standards with regard to regulated exhaust pollutants and associated tier levels. The majority of engines meeting this regulation are factory certified to the same EPA non-road mobile tiers in effect at the time the engine is built. These engines are often certified for both stationary and non-road service. For 2007 through 2010, most stationary diesel engines must meet Tiers 2, 3 or 4, depending on power range. Beginning in 2011, non-emergency engines greater than 130 bkw (175 bhp) and less than 10 liters per cylinder will be required to meet Tier 4 emissions regulations. The EPA has also included instructions for existing engines. If an existing engine or generator set is to be rebuilt, replaced or overhauled, and the cost is more than 50 percent of the price of an equivalent new engine, or if there is an increase in the potential to emit, then the stationary regulation applies. More specifically, if the engine was built before January 1, 2007, and the above conditions are met, that unit must meet Tier 1 emissions after rebuild, repair or overhaul. If the engine was built on or after January 1, 2007, and the conditions are met, the engine must meet the applicable emissions tier level in effect in the year it was manufactured. Tier 4 and electric power: a special case The U.S. EPA Tier 4 emissions regulation came into effect for engines below 37 bkw (approximately 30 ekw or electrical kilowatts) in 2008, and will come into effect in 2011 for diesel powered generator sets rated 130 bkw (approximately ekw) and higher. Generator sets utilizing engines rated 56 to 129 bkw (approximately 45 to 120 ekw) will be Tier 4 starting in So the majority of the diesel powered generator set ratings will be required to be Tier 4 by The regulation, which applies to both stationary and non-road mobile applications, is split into two parts or phase-in periods termed Tier 4 Interim and Tier 4 Final respectively. The initial or interim phase begins in , while more stringent emissions limits come in with Tier 4 Final in the time period. Figure 1 presents an approximate summary of the regulations as applied to stationary and non-road mobile generator set applications from 2009 on. Please note that emergency standby generator sets (defined later in this paper) are exempt from Tier 4 requirements and can be Tier 2 or Tier 3 depending upon the power rating. Figure 1: Phase-in schedule. For , generator sets utilizing engines rated greater than 3000 bhp (2238 bkw) can be certified to Tier 1. For 2011 and beyond, non-emergency generator sets rated greater than 3000 bhp (2238 bkw) must be certified to Tier 4, while emergency generator sets greater than 3000 bhp (2238 bhp) must be certified to Tier 2. 3

4 The Tier 4 regulation requires diesel engine exhaust emissions that are significantly lower than previous tiers. For example, Electric Power Tier 4 Final products will produce approximately 93% less NOx and 94% less particulate matter (PM) compared to Tier 1 products. In some cases, manufacturers might have to incorporate various forms of aftertreatment to meet Tier 4 regulations. The Tier 4 regulations not only apply to new diesel engines used in power generation, but also affect industrial applications, petroleum packages and most, if not all, of the diesel-powered construction equipment used in non-road applications. Since the Tier 4 emissions levels are so low, the EPA decided that emergency standby generator sets, which by their nature run very few hours per year, would be exempt from Tier 4 regulations, including any associated aftertreatment. Furthermore, the EPA states that emergency standby applications can utilize current tier products, which do not require aftertreatment such as today s Tier 2 and Tier 3 offerings. The key to this exemption is the term, emergency standby. That is, what installations qualify as emergency standby? The following definition based upon Caterpillar s interpretation of the EPA regulation should clear up any confusion: Emergency standby installations are those that operate only on the loss of a normal power source such as the utility or the grid. The scenario would be as follows: 1. Normal source power is lost. 2. User starts the standby generator set to supply power to the electrical loads. 3. Normal source power returns. 4. User shuts down the standby generator set and supplies the electrical loads from the normal source. Specific portions of the EPA regulation allow users 100 hours per year of operation for maintenance and exercise requirements, even in the presence of the normal source, and thus the units still qualify as Tier 2 or Tier 3 emergency standby installations. Please note that state or local regulations may further restrict this allowance, so it is important to check with state and local air boards for the most recent interpretation on this issue. If the standby generator set is used to supply building loads and the normal source is present, the generator set must be Tier 4. Examples of this situation include peak shaving, parallel operation with the grid and storm avoidance. All of these applications will have to use Tier 4 certified generator sets. Manufacturers will offer Tier 2, Tier 3 as well as Tier 4 generator sets in 2011 and beyond. The EPA will require specific engine labeling for both emergency and non-emergency products in order to avoid confusion in the field. In 2011 the State of California will most likely have emissions regulations requiring the use of aftertreatment on all standby generator sets including emergency units. As a result, it is believed that the vast majority of standby generator sets sold into the State of California beginning in 2011 will be Tier 4. With this in mind, let s list the applications that will require Tier 4 certified generator sets in 2011: 1. Non-emergency standby units 2. Prime Power applications 3. Load management/peak shaving 4. Electric Power Rental units In addition, there are potential state and local regulations that may drive the use of Tier 4 generator sets in 2011 and beyond. It is imperative that everyone associated with the generator set business be aware of these specific Tier 4 issues when considering future installations. Special local regulations Along with California, some regions and localities have stationary emission limits far more stringent than EPA diesel engine tier levels. These include non-attainment areas in the United States such as Southern California; the New England states; Atlanta, Georgia; and Houston, Texas. The result is that diesel-fueled generator sets deployed in these areas, even if certified to the appropriate EPA tier level, may not meet local requirements. As the U.S. EPA lowers NAAQS levels nationwide, more areas will fall into non-attainment status and thus further restrictions on engine emissions will likely be implemented. 4

5 APPROACHES TO REDUCING DIESEL ENGINE EMISSIONS Depending on the site and the specific pollutant of concern, the following aftertreatment may be used on diesel engines in an effort to meet specific local codes: Selective Catalytic Reduction (SCR) for NOx SCR systems are used to reduce NOx emissions emitted from engines by injecting a second fluid (usually urea) into the exhaust just ahead of the SCR catalyst. The urea reacts with NOx in the presence of the SCR catalyst and is converted into nitrogen gas (N 2 ) and water (H 2 O) (Figure 2). Figure 2: Example of an SCR System Diesel Oxidation Catalyst (DOC) for Carbon Monoxide (CO), Non-Methane Hydrocarbons and Particulate Matter DOCs are installed in the engine exhaust stream to reduce emissions of hydrocarbons (HC), CO and, to a lesser extent particulate matter (PM), by converting them into carbon dioxide (CO 2 ), water (H 2 O) and oxygen (O 2 ). (Figure 3A) Figure 3 A: Oxidation Catalyst Functions Figure 3 B: Oxidation Catalyst Functions Diesel particulate filters (DPF) for particulate matter diesel particulate filters (DPF) are used to remove particulate matter from diesel engine exhaust. They are installed in the exhaust stream and can be packaged in combination with a silencer. DPFs can be either active (requires a regeneration process) or passive (self generating). (Figure 3B) 5

6 THE FUTURE To meet Electric Power product requirements for 2011 and beyond, Caterpillar is working on cost effective solutions to meet both Tier 4 Interim and Tier 4 Final emissions. Specific technical solutions will involve the latest in diesel engine technology and innovation and will use Caterpillar ACERT Technology as the foundation. The resulting Caterpillar Tier 4 Electric Power products will be completely supported by the extensive Caterpillar dealer network. ABOUT About Caterpillar For more than 85 years, Caterpillar Inc. has been making progress possible and driving positive and sustainable change on every continent. With 2012 sales and revenues of $65.9 billion, Caterpillar is a technology leader and the world s leading manufacturer of construction and mining equipment, clean diesel and natural gas engines and industrial gas turbines. Diesel Solutions Center: Online Community: Facebook: YouTube: LLEXE March Caterpillar. All Rights Reserved. CAT, CATERPILLAR, BUILT FOR IT, their respective logos, Caterpillar Yellow, the Power Edge trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. 6

EPA Tier 4 and the Electric Power Industry

EPA Tier 4 and the Electric Power Industry EPA Tier 4 and the Electric Power Industry The initiative to lower diesel engine emissions started with on-highway engines in 1973 and now extends to non-road mobile equipment, marine and locomotive engines,

More information

FREQUENTLY ASKED QUESTIONS TIER 4 INTERIM / STAGE IIIB PRODUCTS

FREQUENTLY ASKED QUESTIONS TIER 4 INTERIM / STAGE IIIB PRODUCTS FAQ FREQUENTLY ASKED QUESTIONS TIER 4 INTERIM / STAGE IIIB PRODUCTS 1 For generations, Caterpillar has been committed to our customers success. As the industry leader, we have a full complement of resources

More information

built for the next generation Cat

built for the next generation Cat built for the next generation Cat Tier 4 Interim / Stage IiIB Technologies 1 advancing technology building customer value The Next Phase in Emissions Reduction Cat Tier 4 Interim/Stage IIIB engines meet

More information

built for the next generation

built for the next generation built for the next generation Cat Tier 4 Interim Technologies 2 THE POWER OF INNOVATION HIGHER PERFORMANCE, LOWER EMISSIONS At Caterpillar, we know you re under constant pressure to do more work at a lower

More information

FOR EVERYONE. and new-source performance standards that strictly regulated emissions of a new source (e.g., automobiles, factories) entering an area.

FOR EVERYONE. and new-source performance standards that strictly regulated emissions of a new source (e.g., automobiles, factories) entering an area. CLEANER AIR FOR EVERYONE AN EVOLUTION OF CLEAN AIR IN NORTH AMERICA AND PART1HOW ENGINE EMISSION REGULATIONS AFFECT YOU One thing is clear the air we breathe is getting cleaner, thanks to years of work

More information

Looking ahead to TIER 4

Looking ahead to TIER 4 Looking ahead to TIER 4 Donora, PA For five days, a cloud of air pollution overtakes the industrial town of Donora, Pennsylvania, sickening 40% of the town. 20 die. 194 8 Where does TIER 4 come from? All

More information

Regulation No. 3 Changes For Internal Combustion Engines. Christine Hoefler November 14, 2012

Regulation No. 3 Changes For Internal Combustion Engines. Christine Hoefler November 14, 2012 Regulation No. 3 Changes For Internal Combustion Engines Christine Hoefler November 14, 2012 Overview Changes to Regulation No. 3 New Source Performance Standard (NSPS) IIII Conflicts with NSPS IIII 2

More information

Looking ahead to tier 4

Looking ahead to tier 4 Looking ahead to tier 4 Donora, PA For five days, a cloud of air pollution overtakes the industrial town of Donora, Pennsylvania, sickening 40% of the town. 20 die. 194 8 Where does tier 4 come from? All

More information

CALIFORNIA S COMPREHENSIVE PROGRAM FOR REDUCING HEAVY- DUTY VEHICLE EMISSIONS

CALIFORNIA S COMPREHENSIVE PROGRAM FOR REDUCING HEAVY- DUTY VEHICLE EMISSIONS CALIFORNIA S COMPREHENSIVE PROGRAM FOR REDUCING HEAVY- DUTY VEHICLE EMISSIONS ACT Research Seminar: North America Commercial Vehicle & Transportation Industries Erik White, Chief Mobile Source Control

More information

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX

RULE STATIONARY GAS TURBINES Adopted (Amended , ) INDEX RULE 413 - STATIONARY GAS TURBINES Adopted 04-06-95 (Amended 05-01-97, 03-24-05) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION - EMERGENCY STANDBY UNITS 111 EXEMPTION - REMOVAL FROM SERVICE

More information

Minimum Power 447 bkw 600 bhp Maximum Power 597 bkw 800 bhp Rated Speed

Minimum Power 447 bkw 600 bhp Maximum Power 597 bkw 800 bhp Rated Speed Specifications Power Rating On construction sites and mining operations, in agriculture and forestry, and in a wide range of industries, Cat C18 ACERT Diesel Engines deliver the power, performance and

More information

IAPH Tool Box for Port Clean Air Programs

IAPH Tool Box for Port Clean Air Programs ENGINE STANDARDS Background Ports around the world depend on the efficiency of the diesel engine to power port operations in each source category ocean/sea-going vessels, harbor craft, cargo handling equipment,

More information

ECONOMICALLY IMPLEMENTING

ECONOMICALLY IMPLEMENTING ECONOMICALLY IMPLEMENTING TIER 4 FINAL POWERPLANTS ON TELEHANDLERS Tier 4 Final Implementation Schedule Barry Greenaway, product manager at Skyjack Inc. highlights the major considerations in the company

More information

Minimum Power 287 bkw 385 bhp Maximum Power 388 bkw 520 bhp

Minimum Power 287 bkw 385 bhp Maximum Power 388 bkw 520 bhp Specifications Power Rating The Cat C13 ACERT Diesel Engine is offered in ratings ranging from 287-388 bkw (385-520 bhp) @ 1800-2100 rpm. Industries and applications powered by C13 ACERT engines include:

More information

Board Administration and Regulatory Coordination Unit. Division 3. Air Resources Board

Board Administration and Regulatory Coordination Unit. Division 3. Air Resources Board 2423. Exhaust Emission Standards and Test Procedures--Heavy-Duty Off-Road Diesel Cycle Engines. (a) This section shall be applicable to new heavy-duty off-road compression-ignition engines, produced on

More information

Regulatory Announcement

Regulatory Announcement EPA Finalizes More Stringent Emissions Standards for Locomotives and Marine Compression-Ignition Engines The U.S. Environmental Protection Agency (EPA) is adopting standards that will dramatically reduce

More information

Evolution Of Tier 4 Regulations & Project Specific Diesel Engine Emissions Requirements

Evolution Of Tier 4 Regulations & Project Specific Diesel Engine Emissions Requirements Evolution Of Tier 4 Regulations & Project Specific Diesel Engine Emissions Requirements Association of Equipment Managers (AEM) CONEXPO / CON-AGG 2014 Las Vegas, NV March 5, 2014 1 1 Topics To Be Covered

More information

Leading the World in Emissions Solutions

Leading the World in Emissions Solutions Leading the World in Emissions Solutions Solutions for Vehicle Emissions CDTI is a leading global manufacturer and distributor of heavy duty diesel and light duty vehicle emissions control systems and

More information

Power Rating Minimum Rating 116 bkw 156 bhp Maximum Rating 205 bkw 275 bhp. 105 mm (4.1 in) 135 mm (5.3 in)

Power Rating Minimum Rating 116 bkw 156 bhp Maximum Rating 205 bkw 275 bhp. 105 mm (4.1 in) 135 mm (5.3 in) Cat C7.1 ACERT Power Unit The C7.1 ACERT Power Unit is a complete power package containing a radiator, flywheel, alternator and alternator wiring, completely pre-assembled for fast, straightforward installation

More information

Minimum Power 224 bkw 300 bhp Maximum Power 298 bkw 400 bhp

Minimum Power 224 bkw 300 bhp Maximum Power 298 bkw 400 bhp Specifications Power Rating The Cat C9.3 ACERT Diesel Engine is offered in ratings ranging from 224-298 bkw (300-400 bhp) @ 1800-2200 rpm. These ratings meet U.S. EPA Tier 4 Final, EU Stage IV emission

More information

RICE NESHAP Frequently Asked Questions (FAQ)

RICE NESHAP Frequently Asked Questions (FAQ) RICE NESHAP Frequently Asked Questions (FAQ) What does RICE NESHAP mean? RICE NESHAP is an acronym for Reciprocating Internal Combustion Engines National Emission Standards for Hazardous Air Pollutants.

More information

ENGINE TECHNOLOGY. Bobcat Engine_B _ _EN_reworked.indd 1

ENGINE TECHNOLOGY. Bobcat Engine_B _ _EN_reworked.indd 1 ENGINE TECHNOLOGY Bobcat Engine_B4459500_01-2015_EN_reworked.indd 1 1/30/2015 10:07:51 AM A COMPANY THAT S GROWING WITH SOCIETY Bobcat prides itself on innovations that shape the future. For decades, we

More information

Power Rating Minimum Power 224 bkw 300 bhp Maximum Power 298 bkw 400 bhp. Emission Standards U.S. EPA Tier 4 Final, EU Stage IV

Power Rating Minimum Power 224 bkw 300 bhp Maximum Power 298 bkw 400 bhp. Emission Standards U.S. EPA Tier 4 Final, EU Stage IV Demanding conditions, applications and environments make the Cat engines in the C9.3 ACERT engines the perfect solution for your severe duty equipment. With decades of diesel engine innovation and expertise

More information

INTERNATIONAL Diesel Engine Emissions Requirements & Technology

INTERNATIONAL Diesel Engine Emissions Requirements & Technology INTERNATIONAL 2010 Diesel Engine Emissions Requirements & Technology Independent Armored Car Operators Association, Inc. 2008 Annual Convention Monday, June 23, 2008 2007 EPA Emissions Standards 1994 500

More information

OFFSHORE EMISSIONS & TEC NOLOGY. Micki J. Jain Product Definition Manager Offshore Global Petroleum Houston, Texas

OFFSHORE EMISSIONS & TEC NOLOGY. Micki J. Jain Product Definition Manager Offshore Global Petroleum Houston, Texas OFFSHORE EMISSIONS & TEC NOLOGY Micki J. Jain Product Definition Manager Offshore Global Petroleum Houston, Texas OFFSHORE EMISSIONS & OFFSHORE EMISSIONS & TECHNOLOGY TECHNOLOGY OFFSHORE EMISSIONS & TECHNOLOGY

More information

Oxidation Technologies for Stationary Rich and Lean Burn Engines

Oxidation Technologies for Stationary Rich and Lean Burn Engines Oxidation Technologies for Stationary Rich and Lean Burn Engines ICAC MARAMA Advances in Air Pollution Control Technologies May 18-19, 2011 Baltimore, MD 1 Overview Oxidation catalyst technologies Oxidation

More information

SCAQMD Rule 1470 Impact on Diesel Generator Installations

SCAQMD Rule 1470 Impact on Diesel Generator Installations SCAQMD Rule 1470 Impact on Diesel Generator Installations Presented Nov 15, 2012 at By Dave Lewis Orange County Chapter Agenda Background EPA / CARB Terminology NEC vs SCAQMD Rule 1470 Requirements http://www.aqmd.gov/rules/reg/reg14/r1470.pdf

More information

Clean Air Construction Standard Draft for Public Comment November 5, 2018

Clean Air Construction Standard Draft for Public Comment November 5, 2018 Clean Air Construction Standard Draft for Public Comment November 5, 2018 Applicability & Effective Date Effective January 1, 2020, the following requirements apply to City of Portland (City) and Multnomah

More information

The Path To EPA Tier 4i - Preparing for. the 2011 transition

The Path To EPA Tier 4i - Preparing for. the 2011 transition The Path To EPA Tier 4i - Preparing for Presented by: Todd Howe Global Product Marketing Manager Doosan Infracore Portable Power Office: 704-883-3611 todd.howe@doosan.com the 2011 transition About the

More information

Metro and you, building together.

Metro and you, building together. metro.net Metro and you, building together. Compliance Guide to Construction Vehicles and Equipment Off-Road off-road equipment Idling effective June 15, 2008 requirement ARB s regulation, Title 13, CCR,

More information

Technology Choices. New Bus Purchases Fleet Make-up Engine Models & Years Driver Education & Support Duty Cycles Fuel Use & Storage

Technology Choices. New Bus Purchases Fleet Make-up Engine Models & Years Driver Education & Support Duty Cycles Fuel Use & Storage What is Retrofit Technology? Retrofit technology can be: any change to an engine system above and beyond what is required by EPA regulations that improves the engine s emission performance: Catalyst or

More information

(2) An engine subject to this rule or specifically exempt by Subsection (b)(1) of this rule shall not be subject to Rule 68.

(2) An engine subject to this rule or specifically exempt by Subsection (b)(1) of this rule shall not be subject to Rule 68. RULE 69.4. STATIONARY RECIPROCATING INTERNAL COMBUSTION ENGINES - REASONABLY AVAILABLE CONTROL TECHNOLOGY (Adopted 9/27/94; Rev. Effective11/15/00; Rev. Effective 7/30/03) (a) APPLICABILITY (1) Except

More information

Diesel Particulate Filter: Exhaust aftertreatment for the reduction of soot emissions

Diesel Particulate Filter: Exhaust aftertreatment for the reduction of soot emissions Engine technology Diesel Particulate Filter: Exhaust aftertreatment for the reduction of soot emissions Authors: Guido Schäffner Design Exhaust Aftertreatment Klaus Rusch Design Exhaust Aftertreatment

More information

March 11, Public Docket A U.S. Environmental Protection Agency Room M-1500, Waterside Mall 401 M Street, SW Washington, DC 20460

March 11, Public Docket A U.S. Environmental Protection Agency Room M-1500, Waterside Mall 401 M Street, SW Washington, DC 20460 March 11, 1999 Public Docket A-97-50 U.S. Environmental Protection Agency Room M-1500, Waterside Mall 401 M Street, SW Washington, DC 20460 To Whom It May Concern: The State and Territorial Air Pollution

More information

How does Exhaust Gas Recirculation work?

How does Exhaust Gas Recirculation work? How does Exhaust Gas Recirculation work? Words: Dr. Johannes Kech Pictures: MTU Tags/Keywords Nitrogen oxide (NOX) emissions can be reduced using internal engine technology by cooling some of the exhaust

More information

What to Expect from Your New Low (and Ultra-Low) Sulfur Fuels

What to Expect from Your New Low (and Ultra-Low) Sulfur Fuels What to Expect from Your New Low (and Ultra-Low) Sulfur Fuels Presented at the Universities National Oceanographic Laboratories System (UNOLS) Research Vessel Operator s Committee (RVOC) F. W. Girshick

More information

MTU presents pioneering EPA Tier 4 final solutions at ConExpo show

MTU presents pioneering EPA Tier 4 final solutions at ConExpo show NEWS RELEASE FOR IMMEDIATE RELEASE Press Information March 22, 2011 Contact: Jennifer Riley MTU Detroit Diesel Phone: +1 313 592 8103 E-mail: jennifer.riley@mtu-online.com Agency contact: Robert E. Sheldon,

More information

Power Rating Minimum Power 36.4 bkw 48.8 bhp Maximum Power 50 bkw 67.1 bhp. Emission Standards U.S. EPA Tier 4 Final, EU Stage IIIB

Power Rating Minimum Power 36.4 bkw 48.8 bhp Maximum Power 50 bkw 67.1 bhp. Emission Standards U.S. EPA Tier 4 Final, EU Stage IIIB The new electronic Cat C2.2 Diesel Engines, with common rail fuel system, deliver impressive performance throughout a wide speed range with exceptional power density. Ultracompact package size and extensive

More information

Bore 145 mm 5.71 in Stroke 162 mm 6.38 in Displacement 32.1 L in 3 Twin Turbocharged-Aftercooled (TTA) Compression Ratio 15.0:1 67.

Bore 145 mm 5.71 in Stroke 162 mm 6.38 in Displacement 32.1 L in 3 Twin Turbocharged-Aftercooled (TTA) Compression Ratio 15.0:1 67. EU Locomotive Stage IIIB 89-895 bkw/5-00 bhp @ 800 rpm Image shown may not reflect actual configuration Specifications Cat C ACERT Metric Imperial (English) Configuration V-, 4-Stroke-Cycle Diesel Bore

More information

Pioneering MTU C&I diesel engines for U.S. EPA Tier 4

Pioneering MTU C&I diesel engines for U.S. EPA Tier 4 Technical Background Article Contact: Mirko Gutemann Phone: +49 7541 90-4741 E-mail: mirko.gutemann@tognum.com Pioneering MTU C&I diesel engines for U.S. EPA Tier 4 For more than 100 years, diesel engines

More information

Power Rating Minimum Power 250 bkw 335 BHP Maximum Power 340 bkw 456 BHP

Power Rating Minimum Power 250 bkw 335 BHP Maximum Power 340 bkw 456 BHP The Cat C9.3B Diesel Engine is offered in ratings ranging from 250-340 bkw (335-456 bhp) @ 1800-2200 rpm. These ratings meet U.S. EPA Tier 4 Final and EU Stage V emission standards. The C9.3B engines are

More information

Internal Combustion Engines Air Updates 2010

Internal Combustion Engines Air Updates 2010 Internal Combustion Engines Air Updates 2010 Stationary Source or Non-road Engine? o Regulated stationary source: 1. At point of use for > 12 months or full operating season (3-12 months) Point of use

More information

Power Solutions. Cat Generator Sets for Petroleum Applications

Power Solutions. Cat Generator Sets for Petroleum Applications Power Solutions Cat Generator Sets for Petroleum Applications Broadest Product Line Single Source Support. Even on a good day, you have enough on your mind without worrying about the reliability of your

More information

DIESEL EMISSIONS TECHNOLOGY SOLUTIONS

DIESEL EMISSIONS TECHNOLOGY SOLUTIONS International Emissions Technology DIESEL EMISSIONS TECHNOLOGY SOLUTIONS GET TOMORROW S PERFORMANCE WITH TODAY S TECHNOLOGY THE BRILLIANCE OF COMMON SENSE. W HY DIESEL TRUCKS AND BUSES ARE THE BEST THING

More information

EPA s National Clean Diesel Campaign and the North American ECA

EPA s National Clean Diesel Campaign and the North American ECA EPA s National Clean Diesel Campaign and the North American ECA AAPA-ESPO Meeting March 23, 2011 Office of Transportation & Air Quality Jim Blubaugh U.S. Environmental Protection Agency Overview Reducing

More information

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14. Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications

More information

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration 3512C Generator Set Electric Power Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

WRITTEN STATEMENT OF THE MANUFACTURERS OF EMISSION CONTROLS ASSOCIATION ON THE U.S

WRITTEN STATEMENT OF THE MANUFACTURERS OF EMISSION CONTROLS ASSOCIATION ON THE U.S WRITTEN STATEMENT OF THE MANUFACTURERS OF EMISSION CONTROLS ASSOCIATION ON THE U.S. ENVIRONMENTAL PROTECTION AGENCY S CONTROL OF EMISSIONS OF AIR POLUTION FROM NEW LOCOMOTIVE ENGINES AND NEW MARINE COMPRESSION-IGNITION

More information

9/17/2013 OVERVIEW WHAT RICE UNITS ARE IMPACTED? WHAT IS A RICE UNIT? EXAMPLES OF RICE UNITS WHY IS THE EPA REGULATING RICE?

9/17/2013 OVERVIEW WHAT RICE UNITS ARE IMPACTED? WHAT IS A RICE UNIT? EXAMPLES OF RICE UNITS WHY IS THE EPA REGULATING RICE? OVERVIEW Compliance Webinar Reciprocating Internal Combustion Engines RICE September 16, 2013 Jesse Zahn, CHMM Jesse.zahn@hrpassociates.com HRP Associates, Inc. Clifton Park, NY 12065 What is RICE Unit

More information

Verified Retrofit Technologies and Product Offerings. Northeast Diesel Collaborative February 26, 2015

Verified Retrofit Technologies and Product Offerings. Northeast Diesel Collaborative February 26, 2015 1 Verified Retrofit Technologies and Product Offerings Northeast Diesel Collaborative February 26, 2015 INTRODUCTION DISCUSSION TOPICS 2 COMPANY OVERVIEW PRODUCT AND MARKET OVERVIEW DIRECT-FIT DESIGN DATABASE

More information

The Future of Transportation Significant Progress...And the challenges Looking Ahead

The Future of Transportation Significant Progress...And the challenges Looking Ahead The Future of Transportation Significant Progress...And the challenges Looking Ahead Dan Greenbaum, President Health Effects Institute HEI Annual Conference Alexandria, Virginia April 30, 2017 The Future

More information

EPA Tier 4 Final: Cleaner Equipment, Cleaner Air

EPA Tier 4 Final: Cleaner Equipment, Cleaner Air EPA Tier 4 Final: Cleaner Equipment, Cleaner Air Understanding the Impact of Tier 4 Final Tier 4 Final (T4F) is the U.S. Environmental Protection Agency s (EPA s) latest step in a series of increasingly

More information

Industrial Power Systems Fueled By Innovation

Industrial Power Systems Fueled By Innovation Industrial Systems Fueled By Innovation Any Job, Anywhere Count on a trusted partner no matter where your work takes you. Cat engines and power systems are at work in applications from the blistering heat

More information

Review of the SMAQMD s Construction Mitigation Program Enhanced Exhaust Control Practices February 28, 2018, DRAFT for Outreach

Review of the SMAQMD s Construction Mitigation Program Enhanced Exhaust Control Practices February 28, 2018, DRAFT for Outreach ABSTRACT The California Environmental Quality Act (CEQA) review process requires projects to mitigate their significant impacts. The Sacramento Metropolitan Air Quality Management District (SMAQMD or District)

More information

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14. Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications Generator Set

More information

EPA s New Nonroad Diesel Rule: Controlling Emissions From Diesel Engines

EPA s New Nonroad Diesel Rule: Controlling Emissions From Diesel Engines HULL MCGUIRE PC ATTORNEYS e-mail: info@hullmcguire.com 600 Grant Street U.S. Steel Tower, 32 nd Floor Pittsburgh, PA 15219 412-261-2600 Phone 412-261-2627 Fax www.hullmcguire.com EPA s New Nonroad Diesel

More information

February 28, Definition of Engines Covered Under the Rule

February 28, Definition of Engines Covered Under the Rule WRITTEN STATEMENT OF THE MANUFACTURERS OF EMISSION CONTROLS ASSOCIATION TO THE OZONE TRANSPORT COMMISSION S SECOND DRAFT MODEL RULE TO CONTROL NOX FROM NATURAL GAS COMPRESSOR FUEL-FIRED PRIME MOVERS February

More information

Yanmar Showcases the comprehensive Diesel and. Gas Engine Line-up at BAUMA 2019

Yanmar Showcases the comprehensive Diesel and. Gas Engine Line-up at BAUMA 2019 News Release January 28 th, 2019 Yanmar Showcases the comprehensive Diesel and Gas Engine Line-up at BAUMA 2019 Gas industrial engine: 4TN88G Munich, Germany (January 28, 2019) - Yanmar will exhibit its

More information

Reducing emissions. Increasing performance.

Reducing emissions. Increasing performance. Reducing emissions. Increasing performance. Now less means more. Finally, emissions solutions that actually benefit the environment and farmers. For the first time since the U.S. and Canadian Environmental

More information

Subject: Emissions Recall 23V1 Approved Emissions Modification for Model Year Volkswagen Touareg 3.0L TDI

Subject: Emissions Recall 23V1 Approved Emissions Modification for Model Year Volkswagen Touareg 3.0L TDI August 2018 Volkswagen Canada P.O. Box 842, Stn. A Windsor, ON N9A 6P2 This notice applies to your vehicle: Subject: Emissions

More information

WRITTEN STATEMENT OF THE MANUFACTURERS OF EMISSION CONTROLS ASSOCIATION ON THE U.S

WRITTEN STATEMENT OF THE MANUFACTURERS OF EMISSION CONTROLS ASSOCIATION ON THE U.S WRITTEN STATEMENT OF THE MANUFACTURERS OF EMISSION CONTROLS ASSOCIATION ON THE U.S. ENVIRONMENTAL PROTECTION AGENCY S PROPOSED STANDARDS OF PERFORMANCE FOR STATIONARY SPARK IGNITION INTERNAL COMBUSTION

More information

Highway Engine Regulations in the U.S.

Highway Engine Regulations in the U.S. Development of Heavy-Duty On- Highway Engine Regulations in the U.S. The 4 th SINO-US Workshop on Motor Vehicle Pollution Prevention and Control U.S. Environmental Protection Agency Office of Transportation

More information

220 to volts. Electronic unit injection

220 to volts. Electronic unit injection Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications

More information

2007 Emissions: Fundamentals

2007 Emissions: Fundamentals A N AV I S TA R C O M PA N Y 2007 Emissions: Fundamentals Study Guide TMT-100718 Study Guide 2007 Emissions: Fundamentals TMT-100718 2007 International Truck and Engine Corporation 4201 Winfield Road,

More information

The Need to Reduce Marine Shipping Emissions

The Need to Reduce Marine Shipping Emissions The Need to Reduce Marine Shipping Emissions Doug Allard, Director, Santa Barbara County Air Pollution Control District Kathy Patton, Division Manager, Santa Barbara County Air Pollution Control District

More information

PATENTED TECHNOLOGY» PROVEN RESULTS» PAYBACK

PATENTED TECHNOLOGY» PROVEN RESULTS» PAYBACK 2328 Bellfort Ave. Houston, Texas 77051 Main 713-821-9600 Fax 713-821-9601 EFFECTS OF ENVIROFUELS DFC ON A LAND DRILLING RIG Oil and Gas Land Drilling Rig PUBLIC VERSION Revision Date February 18, 2008

More information

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards) Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications

More information

New Technology Diesel Engines: Eliminating NOx Emissions from Higher Biodiesel Blends in Un-modified Diesel Engines

New Technology Diesel Engines: Eliminating NOx Emissions from Higher Biodiesel Blends in Un-modified Diesel Engines New Technology Diesel Engines: Eliminating NOx Emissions from Higher Biodiesel Blends in Un-modified Diesel Engines California Biodiesel & Renewable Diesel Conference February 4, 2013 Steve Howell President,

More information

STATEMENT OF BASIS. Cherokee Nitrogen LLC Cherokee, Alabama Colbert County Facility Number

STATEMENT OF BASIS. Cherokee Nitrogen LLC Cherokee, Alabama Colbert County Facility Number STATEMENT OF BASIS Cherokee Nitrogen LLC Cherokee, Alabama Colbert County Facility Number 701-0013 Introduction On June 30, 2017, the Department received an application to renew the Title V Major Source

More information

Advanced Solutions for Meeting EPA Tier 4 Engine Emission Regulations On H HD and Reachstackers

Advanced Solutions for Meeting EPA Tier 4 Engine Emission Regulations On H HD and Reachstackers Advanced Solutions for Meeting EPA Tier 4 Engine Emission Regulations On H400-1150HD and Reachstackers market leading ECO-Technology To address the 2011 U.S. Environmental Protection Agency (EPA) emission

More information

Emission Control Technologies for Locomotive Diesel Engines

Emission Control Technologies for Locomotive Diesel Engines WRITTEN COMENTS OF THE MANUFACTURERS OF EMISSION CONTROLS ASSOCIATION ON TRANSPORT CANADA S PROPOSED RULEMAKING TO CONTROL EMISSIONS OF AIR POLLUTION FROM NEW LOCOMOTIVE ENGINES January 20, 2011 MECA is

More information

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications Generator Set

More information

Presented by. Navistar Education 2015

Presented by. Navistar Education 2015 Presented by Navistar Education 2015 1.2 Overview This course is intended to provide parts specialists with a description of Diesel Exhaust Fluid, or DEF, part number configuration, ordering and distribution

More information

Oxidation Technologies for Stationary Rich and Lean Burn Engines

Oxidation Technologies for Stationary Rich and Lean Burn Engines Oxidation Technologies for Stationary Rich and Lean Burn Engines Advances in Emission Control and Monitoring Technology for Industrial Sources Exton, PA July 9-10, 2008 1 Oxidation Catalyst Technology

More information

ATTACHMENT C.1 EXXONMOBIL INTERIM TRUCKING FOR SYU PHASED RESTART AIR QUALITY ANALYSIS

ATTACHMENT C.1 EXXONMOBIL INTERIM TRUCKING FOR SYU PHASED RESTART AIR QUALITY ANALYSIS ATTACHMENT C.1 EXXONMOBIL INTERIM TRUCKING FOR SYU PHASED RESTART AIR QUALITY ANALYSIS Revision 2 Page 1 of 7 January 2018 ExxonMobil Production Company, a division of Exxon Mobil Corporation (ExxonMobil

More information

1206F-E70TTA Industrial Diesel Engine

1206F-E70TTA Industrial Diesel Engine The 6 cylinder option for the Perkins 1200 Series, the 1206F gives you a complete power solution that meets EU Stage IV/U.S. Tier 4 Final emission standards. The choice of options, engine configurations

More information

WRAP Oil & Gas: 2002/2005 and 2018 Area Source Controls Evaluation

WRAP Oil & Gas: 2002/2005 and 2018 Area Source Controls Evaluation WRAP Oil & Gas: 2002/2005 and 2018 Area Source Controls Evaluation WRAP SSJF Oil and Gas Work Group Members and Other Interested Parties May 30, 2007 1 WRAP Phase II Project Overview Project is focused

More information

IMPORTANT INFORMATION ABOUT YOUR L TDI Volkswagen

IMPORTANT INFORMATION ABOUT YOUR L TDI Volkswagen IMPORTANT INFORMATION ABOUT YOUR 2009-2010 3.0L TDI Volkswagen 1 Contents About This Booklet... 1 Overview... 2 Software and Hardware Updates... 3 Maintenance Schedule... 6 Emissions Limits... 6 Extended

More information

Heavy-Duty Diesel Emission Control Technologies to Achieve Future Emission Reduction Goals

Heavy-Duty Diesel Emission Control Technologies to Achieve Future Emission Reduction Goals Heavy-Duty Diesel Emission Control Technologies to Achieve Future Emission Reduction Goals Mid-Atlantic Diesel Collaborative March 3, 2016 Conference Call Dr. Rasto Brezny Manufacturers of Emission Controls

More information

Air Permitting: Municipal Facilities with Emergency Generators

Air Permitting: Municipal Facilities with Emergency Generators Air Permitting: Municipal Facilities with Emergency Generators Sam Cotter, P.E. sam.cotter@cardinalengineers.com 7060 S. Yale, Suite 603 Tulsa, OK 74136 Introduction Generators are located at our utility

More information

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14. Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications Generator Set

More information

San Pedro Bay Ports. Port of Los Angeles 7.9 million TEUs Port of Long Beach 6.0 million TEUs. Total 13.9 million TEUs in 2011

San Pedro Bay Ports. Port of Los Angeles 7.9 million TEUs Port of Long Beach 6.0 million TEUs. Total 13.9 million TEUs in 2011 Port Background San Pedro Bay Ports Port of Los Angeles 7.9 million TEUs Port of Long Beach 6.0 million TEUs Total 13.9 million TEUs in 2011 San Pedro Bay Port Complex Emissions and the Clean Air Action

More information

California s Success in Controlling Large Industrial Sources

California s Success in Controlling Large Industrial Sources California s Success in Controlling Large Industrial Sources Endicott House 2006 Symposium Mike Scheible Deputy Executive Officer California Air Resources Board California Environmental Protection Agency

More information

A Tool for Specifying Diesel Genset Replacements Steve Stassel, Gray Stassel Engineering

A Tool for Specifying Diesel Genset Replacements Steve Stassel, Gray Stassel Engineering A Tool for Specifying Diesel Genset Replacements Steve Stassel, Gray Stassel Engineering Alaska Rural Energy Conference, April 28, 2016 (Technical Session 6, 10:30 am) EPA Regulations RICE NESHAP on or

More information

Calstart Ontario Diesel Vehicle Regulation Overview

Calstart Ontario Diesel Vehicle Regulation Overview Calstart Ontario 2011 Diesel Vehicle Regulation Overview Eloy Florez, Air Pollution Specialist In Use Control Measures California Air Resources Board 1 Why Have Air Pollution Control Regulations? Clear

More information

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY WASHINGTON, D.C

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY WASHINGTON, D.C UNITED STATES ENVIRONMENTAL PROTECTION AGENCY WASHINGTON, D.C. 20460 OFFICE OF AIR AND RADIATION WHAT YOU SHOULD KNOW ABOUT USING, INSTALLING, OR BUYING AFTERMARKET CATALYTIC CONVERTERS As of January 1,

More information

Air Quality Mandates Affecting the Caltrans Fleet Caltrans Division of Equipment Sacramento, CA June, 2009

Air Quality Mandates Affecting the Caltrans Fleet Caltrans Division of Equipment Sacramento, CA June, 2009 Air Quality Mandates Affecting the Caltrans Fleet Caltrans Division of Equipment Sacramento, CA June, 2009 Presentation Overview ARB On Road Mandate ARB Off Road Mandate South Coast AQMD Fleet Rules ARB

More information

Questions & Answers. Vermont Clean Diesel Grant Program. Release Date: July 14, 2017 Proposals Due: August 14, 2017 at 4:00 pm

Questions & Answers. Vermont Clean Diesel Grant Program. Release Date: July 14, 2017 Proposals Due: August 14, 2017 at 4:00 pm Questions & Answers Vermont Clean Diesel Grant Program Release Date: July 14, 2017 Proposals Due: August 14, 2017 at 4:00 pm Q & A/ In Person Meeting: July 25, 2017 10:00 am - 12:00 pm National Life Building

More information

Zorik Pirveysian, Air Quality Policy and Management Division Manager Policy and Planning Department

Zorik Pirveysian, Air Quality Policy and Management Division Manager Policy and Planning Department Environment Committee Meeting: April 11, 2006 To: From: Environment Committee Zorik Pirveysian, Air Quality Policy and Management Division Manager Policy and Planning Department Date: March 20, 2006 Subject:

More information

Power Rating Minimum Power 746 bkw 1000 bhp Maximum Power 895 bkw 1200 bhp. Emission Standards U.S. EPA Tier 4 Final

Power Rating Minimum Power 746 bkw 1000 bhp Maximum Power 895 bkw 1200 bhp. Emission Standards U.S. EPA Tier 4 Final No matter where they operate and no matter what the application, these high horsepower Cat C32 ACERT Diesel engines will deliver durable, reliable power that will keep your customers productive while lowering

More information

THE POWER YOU LIVE BY. Caterpillar Marine Generator Sets

THE POWER YOU LIVE BY. Caterpillar Marine Generator Sets THE POWER YOU LIVE BY Caterpillar Marine Generator Sets Broadest Product Line Single Source Support. Even on a good day, you have enough on your mind without worrying about the reliability of your marine

More information

m b e E M I S S I O N S E N G I N E

m b e E M I S S I O N S E N G I N E m b e 4 0 0 0 2 0 0 7 E M I S S I O N S E N G I N E We re DRIVING TECHNOLOGY. Detroit Diesel and Mercedes-Benz have over 150 combined years of experience designing, testing and manufacturing diesel engines.

More information

NARRATIVE. Dika Kuoh Steve Allison DATE: August 5, 2015

NARRATIVE. Dika Kuoh Steve Allison DATE: August 5, 2015 Georgia Department of Natural Resources Environmental Protection Division Air Protection Branch 4244 International Parkway Suite 120 Atlanta Georgia 30354 404/363-7000 Fax: 404/363-7100 Judson H. Turner,

More information

Learning Legacy Document

Learning Legacy Document SUSTAINABILITY & CONSENTS Guidance on Diesel Engine Emissions from Non-Road Mobile Machinery (NRMM) and retrofitting with Diesel Particulate Filters (DPF) Document History: Document Number: CR-XRL-T1-GUI-CR001-50005

More information

Inspection of Vehicles Equipped with 2007 or Later EPA-Certified Engines

Inspection of Vehicles Equipped with 2007 or Later EPA-Certified Engines Summary Created: Nov. 19, 2008 Revised: May 19, 2010 Revised: April 27, 2017 This Inspection Bulletin explains how to safely inspect motorcoaches, buses, trucks and truck tractors equipped with 2007 or

More information

1204F-E44TA Industrial Diesel Engine

1204F-E44TA Industrial Diesel Engine The Perkins 1204F, the 4 cylinder option for the 1200 Series, gives you a complete power solution that meets the latest EU Stage IV/U.S. EPA Tier 4 Final emission standards. The choice of options, engine

More information

The topic of exhaust emission regulation and reduction is extremely complex. In order to comply with the permissible emission values, increasingly

The topic of exhaust emission regulation and reduction is extremely complex. In order to comply with the permissible emission values, increasingly READY? We are! 2 By way of numerous patents and INNOVATIONS, we at DEUTZ have played a definitive part in co-determining the development of the modern diesel engine, and as a result have always been a

More information

Technology Advancement Program. Presented by: Heather Tomley, Port of Long Beach Kevin Maggay, Port of Los Angeles

Technology Advancement Program. Presented by: Heather Tomley, Port of Long Beach Kevin Maggay, Port of Los Angeles Technology Advancement Program Presented by: Heather Tomley, Port of Long Beach Kevin Maggay, Port of Los Angeles Overview Key to the ports Clean Air Action Plan Goals and structure of the Technology Advancement

More information

offshore power Caterpillar Global Petroleum

offshore power Caterpillar Global Petroleum offshore power Caterpillar Global Petroleum PROVEN RELIABILITY AND DURABILITY With over 60 years of petroleum power experience and everything from small generator sets to offshore drilling modules. Caterpillar

More information

DRAFT April 9, STATE IMPLEMENTATION PLAN CREDIT FOR EMISSION REDUCTIONS GENERATED THROUGH INCENTIVE PROGRAMS (Adopted [adoption date])

DRAFT April 9, STATE IMPLEMENTATION PLAN CREDIT FOR EMISSION REDUCTIONS GENERATED THROUGH INCENTIVE PROGRAMS (Adopted [adoption date]) RULE 9610 STATE IMPLEMENTATION PLAN CREDIT FOR EMISSION REDUCTIONS GENERATED THROUGH INCENTIVE PROGRAMS (Adopted [adoption date]) 1.0 Purpose The purpose of this rule is to provide an administrative mechanism

More information