Supplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478

Size: px
Start display at page:

Download "Supplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478"

Transcription

1 Supplementary instructions Mounting accessories, pressure measurement technology Document ID: 78

2 Contents Contents About this document.... Function.... Target group.... Symbols used... For your safety.... Authorised personnel.... Appropriate use.... Warning about incorrect use.... General safety instructions....5 Environmental instructions... Siphons Use Types... 6 Blocking valves Use Blocking valve according to DIN Blocking valve ½ NPT.... Double blocking valve according to DIN Double blocking valve ½ NPT... 5 Valve blocks Use fold valve block fold valve block, flanging on both sides fold valve block Adapter Oval flange adapter... 7 Measuring instrument holder and mounting bracket Measuring instrument holder Mounting bracket... 8 Mounting and measurement setups (Hook Ups) Pressure measurement Differential pressure measurement Maintenance and fault rectification Maintenance Resealing How to proceed if a repair is necessary... Safety instructions for Ex areas Please note the Ex-specific safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments. Editing status:

3 About this document About this document. Function This supplementary instructions manual is valid in conjunction with the operating instructions of the instrument. It gives you all necessary information for a quick setup and safe operation of the instrument with accessory. Therefore read both instructions manuals before you start setup.. Target group This operating instructions manual is directed to trained specialist personnel. The contents of this manual should be made available to these personnel and put into practice by them.. Symbols used Information, tip, note This symbol indicates helpful additional information. Caution: If this warning is ignored, faults or malfunctions can result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result. Ex applications This symbol indicates special instructions for Ex applications. List The dot set in front indicates a list with no implied sequence. Action This arrow indicates a single action. Sequence of actions Numbers set in front indicate successive steps in a procedure.

4 For your safety For your safety. Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the device the required personal protective equipment must always be worn.. Appropriate use The mounting accessory, pressure measurement technology is used for connection of pressure and differential pressure transmitters to a process. You can find detailed information on the application range with the respective accessory part.. Warning about incorrect use Inappropriate or incorrect use of the instrument can give rise to application-specific hazards, e.g. vessel overfill or damage to system components through incorrect mounting or adjustment.. General safety instructions The safety information in the operating instructions manual of the respective sensor must be noted..5 Environmental instructions Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection. The environment management system is certified according to DIN EN ISO 00. Please help us fulfil this obligation by observing the environmental instructions in this manual: Chapter "Storage and transport" Chapter "Disposal"

5 Siphons Siphons Application/Function. Use Siphons according to DIN 68 are a cooling zone for protection of the pressure transmitters against too hot process media. Through condensation in the elbow pipe, a protective water accumulation is formed. Even in applications with hot steam, a medium temperature < 00 C on the transmitter is ensured. There are two different series of siphons: the u-form for horizontal pressure extraction and the circular form for vertical pressure extraction. bar C Fig. : Temperature derating - max. permissible pressure depending on the process temperature Mounting/operation Configuration With steam applications, the siphon must be filled with water before setup. Hence, you can avoid that until condensation, hot steam penetrates directly into the pressure transmitter. The siphon must not be isolated. Move under to "Products" and "Siphon". 5

6 Siphons U-form, form A. Types 80 mm (7.09") 5 mm (5.7") G ½ 55 mm (6.0") ø 6 mm (0.") G ½ 00 mm (7.87") 56 mm (.") Fig. : Siphon according to DIN 68, U-form for horizontal pressure extraction, form A Input, thread G½, manometer connection Output, clamping sleeve with inner thread G½ manometer connection U-form, form B 5 mm (5.7") G ½ 55 mm (6.0") 00 mm (7.87") 6 Fig. : Siphon according to DIN 68, U-form for horizontal pressure extraction, form B Input, weld-on end 0 x.6 Output, clamping sleeve with inner thread G½ manometer connection

7 Siphons Circular form, form C G ½ 0 mm (9.5") Fig. : Siphon according to DIN 68, circular form for vertical pressure extraction, form C Input, weld-on end 0 x.6 Output, clamping sleeve with inner thread G½ manometer connection Circular form, form D G ½ ø 56 mm (.") 0 mm (.") 95 mm (.7") 0 mm (5.") 75 mm (0.8") G ½ Fig. 5: Siphon according to DIN 68, circular form for vertical pressure extraction, form D Input, thread G½ Output, clamping sleeve with inner thread G½ manometer connection 7

8 Siphons Technical data Feature Characteristic Material Steel (.05), 6Ti Standard DIN 68 Series Form A, form D Input Fitting G½, EN 87 Output Clamping sleeve G½, EN 87 Weight approx. 0.8 kg Feature Characteristic Material Steel (.05), 6Ti Standard DIN 68 Series Form B, form C Input Weld-on end 0 x.6 Output Clamping sleeve G½, EN 87 Weight approx. 0.8 kg 8

9 Blocking valves Blocking valves Application/Function Mounting/operation Configuration. Use Blocking valves according to DIN 670 enable simple mounting, setup and dismounting of a pressure transmitter with process fitting G½ or ½ NPT. The ventilation screw with single valves enables the removal of residual air as well as a relieve of the residual pressure between valve and pressure transmitter. The ventilation/test valve with double blocking valves enables two functions with closed process valve: Ventilation of the pressure transmitter Checking the pressure transmitter via a connected pressure calibrator. The valve is opened by turning it anticlockwise or closed by turning it clockwise. The sealing to the medium is made via a flat seal or metallically, the seal of the valve spindle is a gland packing. The ventilation opening must be assigned and the ventialtion carried out in such a way that neither persons nor the environment will be in danger by penetrating medium. For ventilation of a blocking valve proceed as follows:. Open valve (). Open ventilation screw () carefully until air escapes. Close the ventilation screw () as soon as medium penetrates The ventilation is hence finished. Rust, sand or similar pollution in the medium can build up around the valve seat, especially when the system is flushed out before the first setup. This can cause leakage around the valve seat. The spindle must therefore be fully opened to permit flushing out. When the prepressed packing is stored for a longer time, its sealing ability can deteriorate. If necessary, the seal must be retightened at the time of setup. The procedure is described in chapter "Maintenance and fault rectification". Move under to "Products" and "Valve". 9

10 Blocking valves Configuration. Blocking valve according to DIN 670 G ½ G ½ 00 mm (.9") G ½ DIN EN mm (.5") Technical data 0 Fig. 6: Configuration of blocking valve according to DIN 670 Input (process) Valve for blocking (process) Ventilation screw Output (pressure transmitter) Feature Housing material Material: seal packing Characteristic 6Ti PTFE Standard DIN 670 Series Form A, with clamping sleeve Input Fitting G½, EN 87 Output Ventilation screw Ventilation/Test connection Pressure stage/max. permissible pressure Clamping sleeve G½ Yes No PN 00/00 bar Temperature acc. to DIN max. 0 C Weight approx. 0.6 kg

11 Blocking valves Configuration. Blocking valve ½ NPT / - NPT 90 mm (.5") 60 mm (6.0") /" NPT / - NPT Fig. 7: Configuration blocking valve ½ NPT Input (process) Valve for blocking (process) Ventilation screw Output (pressure transmitter) Technical data Feature Housing material Material: valve seal packing Input Output Ventilation/Test connection Pressure stage/max. permissible pressure Operating pressure at 80 C Characteristic 6L PTFE Pin ½ NPT Sleeve ½ NPT ¼ NPT, with closing screw PN 0/0 bar 00 bar

12 Blocking valves Feature Operating pressure at 60 C Operating temperature/brief temperature Weight Characteristic 70 bar 60 C/00 C approx. 0.9 kg Configuration. Double blocking valve according to DIN mm (.9") 00 mm (.9") G ½ G ½ 00 mm (.9") G ½ DIN EN 87- M0 x,5 5 5 Technical data Fig. 8: Configuration of double blocking valve according to DIN 67 Input (process) Valve for blocking (process) Output (pressure transmitter) Valve for ventilation 5 Ventilation/Test Feature Housing material Material: valve seal packing Characteristic 6Ti PTFE Input Fitting G½, EN 87

13 Blocking valves Feature Output Characteristic Protective cap M0 x.5 Pressure stage/max. permissible pressure Clamping sleeve G½ PN 0/0 bar Temperature max. 0 C Weight approx. 0.9 kg Configuration.5 Double blocking valve ½ NPT 5 / NPT / NPT 00 mm (.9") / NPT 5 Fig. 9: Configuration double blocking valve ½NPT Input (process) Valve for blocking (process) Valve for ventilation Ventilation/Test 5 Output (pressure transmitter) Technical data Feature Housing material Material: valve seal packing Input Output Ventilation/Test connection Pressure stage/max. permissible pressure Characteristic 6L PTFE Pin ½ NPT Sleeve ½ NPT ¼ NPT, with closing screw PN 0/0 bar

14 Blocking valves Feature Operating pressure at 80 C Operating pressure at 60 C Operating temperature/brief temperature Weight Characteristic 00 bar 70 bar 60 C/00 C approx. 0.9 kg

15 5 Valve blocks 5 Valve blocks Application/Function Mounting/operation Configuration 5. Use Valve blocks enable simple installation and setup of a differential pressure transmitter. Process valves are used to block the transmitter to the process. When the process valves are closed, the equalization valve enables a pressure compensation for the measuring chambers. This allows the zero point of the pressure transmitter to be adjusted. The 5-fold valve block has two additional outlet valves for blowing out the process lines or checking the differential pressure transmitter. The valves are opened (turning anticlockwise) or closed (turning clockwise) with hand wheels. The seal to the medium is metallic, the seal of the valve spindle is a gland packing. The valves blocks are available in the following versions: -fold valve block -fold valve block, flanging on both sides 5-fold valve block The mounting is carried out via integrated threaded connections and a bracket existing on site. The mounting with -fold valve block for mounting on both sides is made vial integrated flanges with threaded connection to the orifice. Rust, sand or similar pollution in the medium can build up around the valve seat, especially when the system is flushed out before the first setup. This can cause leakage around the valve seat. The spindle must therefore be fully opened to permit flushing out. When the prepressed packing is stored for a longer time, its sealing ability can deteriorate. If necessary, the seal must be retightened at the time of setup. The procedure is described in chapter "Maintenance and fault rectification". Move under to "Products" and "Valve block". 5

16 5 Valve blocks Configuration 5. -fold valve block, mm (.6") ø,8 mm (0.7") mm (.6") 6 mm (.5") 7 mm (.6") M 0 5 mm (.58") 5 mm (.") mm (.5") / NPT 5,8 mm (.5") 0 mm (8.66") Technical data 6 Fig. 0: Configuration of -fold valve block according to EN 658 Input (process) Valves for blocking (process) Breather valve Output (differential pressure transmitter) 5 Through-holes for mounting screws 6 Holes for mounting bracket Feature Housing material Material: process seal Material: valve seal packing Characteristic 6L PTFE, FFKM PTFE Standard EN 658 Series Mounting thread for bracket provided on site Input (process) Output (differential pressure transmitter) Pressure stage/max. permissible pressure Operating pressure at 80 C -fold valve block, flange mounting possible M 0 ½ NPT Flange according to EN 658 PN 0/0 bar 00 bar

17 5 Valve blocks Feature Operating pressure at 60 C Operating temperature/brief temperature Weight Characteristic 70 bar 60 C/00 C approx..7 kg Configuration 5. -fold valve block, flanging on both sides, mm (.6") ø 7 mm / 6" UNF (0.8") 5 EN ø,5 mm (0.5") 5 mm (.") 00 mm (.9") EN 658 / NPT 75 mm (.95") Fig. : Configuration of -fold valve block according to EN 658 Input (process) Valves for blocking (process) Breather valve Output (differential pressure transmitter) 5 Threaded holes for the process 6 Through-holes for differential pressure transmitter Technical data Feature Characteristic Housing material 6L Material: process seal PTFE, FFKM Material: valve seal packing PTFE Standard EN 658 7

18 5 Valve blocks Feature Series Input (process) Output (differential pressure transmitter) Ventilation openings Pressure stage/max. permissible pressure Max. permissible pressure at 80 C/50 C Characteristic -fold valve block, flange mounting possible ½ NPT Flange according to EN 658 ¼ NPT (with plug) PN 0/0 bar 0 bar/00 bar Temperature max. 50 C Weight approx..6 kg 8

19 5 Valve blocks Configuration 5. 5-fold valve block / NPT / NPT, mm (.6") 6 6 mm (.5") 7 mm (.6") mm (.6") 5 mm (.") mm (.5") ø,8 mm (0.7"),8 mm (.5") 05 mm (.") 5 9 mm (.50") 5 5 Fig. : Configuration of 5-fold valve block according to EN 658 Input (process) Valves for blocking (process) Breather valve Blow-off valves 5 Output (differential pressure transmitter) 6 Through-holes for mounting screws 7 Holes for mounting bracket Technical data Feature Housing material Material: process seal Material: valve seal packing Characteristic 6L PTFE, FFKM PTFE 9

20 5 Valve blocks Feature Characteristic Standard EN 658 Series Mounting thread for bracket provided on site Input (process) Output (differential pressure transmitter) Blowing out/test connection Pressure stage/max. permissible pressure Operating pressure at 80 C Operating pressure at 60 C Operating temperature/brief temperature Weight 5-fold valve block, flange mounting possible M0 (DIN EN 0) ½ NPT Flange according to EN 658 ¼ NPT PN 0/0 bar 00 bar 70 bar 60 C/00 C approx. 6.5 kg 0

21 6 Adapter 6 Adapter Application/Function Configuration 6. Oval flange adapter An oval flange adapter enables the connection of an ½ NPT tube to a differential pressure transmitter or a valve block. A-A A ø,8 mm (0.6") 7 mm (.06"), mm (.6") / NPT A 9 mm (.5") ø,8 mm (0.6") Fig. : Oval flange adapter Input (process) Output (differential pressure transmitter/valve block) Technical data Configuration Feature Characteristic Material Adapter.060, 6L, Alloy C76 (.89) Process seal Screws PN 60/PN 0 FKM, EPDM, PTFE, FFKM 0/Steel 8.8 galvanized Screws M0 (DIN EN 0 ), 7/6 UNF Input Process ½ NPT Output Temperature range: process seal Weight Differential pressure transmitter Flange according to EN 658 FKM C EPDM C PTFE C FFKM (Kalrez 675) C FFKM (Perlast G9E) C approx. 0. kg Move under to "Products" and "Oval flange adapter".

22 7 Measuring instrument holder and mounting bracket 7 Measuring instrument holder and mounting bracket Application/Function Mounting Configuration 7. Measuring instrument holder The measuring instrument holder is used for mounting process pressure and suspension pressure transmitters. Adaptation to different instrument diameters is accomplished by means of supplied reduction pieces for the diameters,,, 0 and mm. The measuring instrument holder is mounted on tubes of diameter ½" ½" via the mounting strap. Without mounting strap, it is used as a console for wall mounting. 90 mm (.5") 70 mm (.76") R mm (.6") mm (.5") M6 7 mm (6.77") Fig. : Configuration of measuring instrument holder Mounting tube/pressure transmitter with mm Pressure transmitter Technical data Feature Characteristic Material 6L, 0 Material reduction piece PP Weight approx. 0. kg Configuration Application/Function Move under to "Products" and "Meas. instrument holder". 7. Mounting bracket The mounting bracket is used for wall or tube mounting of differential pressure transmitters.

23 7 Measuring instrument holder and mounting bracket Configuration 5 mm (5.") 7,5 mm (.8") mm (.88") 7 mm (.9") 7 mm (.9") 06 mm (.7") 97,5 mm (.8") Fig. 5: Configuration of mounting bracket Holes mm for bracket or wall mounting Openings for connection of differential pressure transmitters according to IEC 658 Technical data Feature Characteristic Material 0 Weight approx. 0.9 kg Configuration Move under to "Products" and "Mounting bracket".

24 8 Mounting and measurement setups (Hook Ups) 8 Mounting and measurement setups (Hook Ups) Gaseous (blocking valve according to DIN 670) 8. Pressure measurement Position Piece Designation Pipeline with discharge socket and tension sleeve Seal washer acc. to EN 87- Blocking valve DIN 670 form A with ventilation screw Blocking valve DIN 670 form A with test connection Pressure transmitter with G½ connection acc. to EN 87 Gaseous (valve NPT)

25 8 Mounting and measurement setups (Hook Ups) Position Piece Designation Pipeline with discharge socket Valve NPT Double valve NPT Pressure transmitter with ½ NPT connection Gaseous/liquid (double blocking valve according to DIN 670) Position Piece Designation Quadrant pipe with clamping sleeve G½ inner Seal washer acc. to EN 87- Double blocking valve DIN 67 form A, G½ outer thread/clamping sleeve with test connection Pressure transmitter with G½ connection acc. to EN 87 5

26 8 Mounting and measurement setups (Hook Ups) Vaporous/liquid (blocking valve acc. to DIN 670) Position Piece Designation Siphon U-form with clamping sleeve G½ inner Seal washer acc. to EN 87- Blocking valve DIN 67 form A, G½ outer thread/clamping sleeve with test connection Pressure transmitter with G½ connection acc. to EN 87 6

27 8 Mounting and measurement setups (Hook Ups) Vaporous (blocking valve according to DIN 67) Position Piece Designation Siphon in circular form Seal washer acc. to EN 87- Double blocking valve DIN 67 form A, G½ outer thread/clamping sleeve with test connection Pressure transmitter with G½ connection acc. to EN 87 7

28 8 Mounting and measurement setups (Hook Ups) Gaseous (-fold valve block, flanging on both sides) 8. Differential pressure measurement Position Piece Designation Orifice with oval flange connection Screws and seals -fold valve block, flanging on both sides Differential pressure transmitter with connection acc. to IEC 658 8

29 8 Mounting and measurement setups (Hook Ups) Gaseous (-fold valve block) Position Piece Designation Pipeline with discharge socket Threaded fitting ½- NPT/SRV S Threaded fitting ½- NPT/Compression fitting ø mm Effective pressure line ø mm -fold valve block, input ½- NPT inner thread 5 Differential pressure transmitter with connection acc. to IEC Ventilation valves 9

30 8 Mounting and measurement setups (Hook Ups) Position Piece Designation 7 Mounting bracket 8 Mounting screws Liquid (-fold valve block) Position Piece Designation Pipeline with discharge socket Threaded fitting ½- NPT/SRV S Threaded fitting ½- NPT/Compression fitting ø mm Effective pressure line ø mm -fold valve block 5 Differential pressure transmitter with connection acc. to IEC Mounting bracket 7 Mounting screws

31 9 Maintenance and fault rectification 9 Maintenance and fault rectification 9. Maintenance If the device is used properly, no special maintenance is required in normal operation. 9. Resealing If a valve in the packing leaks, it can be resealed during operation. To reseal it, proceed as follows:. Open the valve completely with the T-handle 5 Fig. : General configuration of a valve T-handle Gland nut Counter nut Gland packing 5 Valve spindle. Loosen counter nut. Slightly tighten the gland nut by turning clockwise. Move spindle several times in both directions 5. Tighten counter nut 6. Test for tightness The resealing procedure is finished. 9. How to proceed if a repair is necessary You can find an instrument return form as well as detailed information about the procedure in the download area of our homepage: By doing this you help us carry out the repair quickly and without having to call back for needed information. If a repair is necessary, please proceed as follows: Print and fill out one form per instrument Clean the instrument and pack it damage-proof

32 9 Maintenance and fault rectification Attach the completed form and, if need be, also a safety data sheet outside on the packaging Please contact the agency serving you to get the address for the return shipment. You can find the agency on our home page

33 Notes

34 Notes

35 Notes 5

36 Printing date: All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing. Subject to change without prior notice VEGA Grieshaber KG, Schiltach/Germany 07 VEGA Grieshaber KG Am Hohenstein 7776 Schiltach Germany Phone Fax

Supplementary instructions Heating for the display and adjustment module PLIC- SCOM

Supplementary instructions Heating for the display and adjustment module PLIC- SCOM Supplementary instructions Heating for the display and adjustment module PLIC- SCOM Document ID: 31708 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbols used...

More information

Supplementary instructions. Air cooling - FIBERTRAC 31 with Conduit tube connection. Active air cooling system for radiation-based sensors

Supplementary instructions. Air cooling - FIBERTRAC 31 with Conduit tube connection. Active air cooling system for radiation-based sensors Supplementary instructions Air cooling - FIBERTRAC 31 with Conduit tube connection Active air cooling system for radiation-based Document ID: 52847 Contents Contents 1 Product description 1.1 Configuration...

More information

Supplementary instructions Flanges according to DIN - EN - ASME - JIS - GOST Technical data. Document ID: 31088

Supplementary instructions Flanges according to DIN - EN - ASME - JIS - GOST Technical data. Document ID: 31088 Supplementary instructions Flanges according to DIN - EN - ASME - JIS - GOST Technical data Document ID: 10 1 Product description 1 Product description 1.1 Specifications The described flanges are threaded

More information

Supplementary instructions. Air cooling - FIBERTRAC 31. Active air cooling system for radiation-based sensors. Document ID: 50339

Supplementary instructions. Air cooling - FIBERTRAC 31. Active air cooling system for radiation-based sensors. Document ID: 50339 Supplementary instructions Air cooling - FIBERTRAC 31 Active air cooling system for radiation-based sensors Document ID: 50339 Contents Contents 1 Product description 1.1 Configuration... 3 2 Mounting

More information

Operating Instructions OPTISWITCH 4000 C with transistor output

Operating Instructions OPTISWITCH 4000 C with transistor output Operating Instructions OPTISWITCH 4000 C with transistor output Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbolism used... 3 2 For your safety 2.1 Authorised

More information

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107 Supplementary instructions Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family Document ID: 4107 Contents Contents 1 For your safety... 1.1 Appropriate use...

More information

Supplementary instructions. Water cooling - MINITRAC 31. Active water cooling system for radiationbased. Document ID: 48522

Supplementary instructions. Water cooling - MINITRAC 31. Active water cooling system for radiationbased. Document ID: 48522 Supplementary instructions Water cooling - MINITRAC 31 Active water cooling system for radiationbased sensors Document ID: 48522 Contents Contents 1 Product description... 3 1.1 Configuration... 3... 4

More information

Supplementary instructions. Centering. for VEGAFLEX series 80. Document ID: 44967

Supplementary instructions. Centering. for VEGAFLEX series 80. Document ID: 44967 Supplementary instructions Centering for VEGAFLEX series 80 Document ID: 44967 Contents Contents 1 Product description 1.1 Overview... 3 1.2 Centerings... 3 2 Mounting 2.1 General instructions... 10 2.2

More information

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure Level measurement Guided microwave Product Information VEGAFLEX 62 4 20 ma/hart Level Switching Pressure 2 VEGAFLEX 62 4 20 ma/hart Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2

More information

Operating Instructions April 2008 SITRANS LVL100

Operating Instructions April 2008 SITRANS LVL100 Operating Instructions April 2008 SITRANS LVL100 Content Content 1 About this document 1.1 Function............................. 4 1.2 Target group.......................... 4 1.3 Symbolism used.......................

More information

Operating Instructions 07/2013

Operating Instructions 07/2013 Vibrating Switches SITRANS LVL100 - transistor (PNP) Operating Instructions 07/2013 2 SITRANS LVL100 - Operating Instructions Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3

More information

Pressure Reducing Valve Type 2114/2415

Pressure Reducing Valve Type 2114/2415 Pressure Reducing Valve Type 2114/2415 Fig. 1 Type 2114/2415 1. Design and principle of operation The Type 2114/2415 Pressure Reducing Valve consists of the Type 2114 Valve and the Type 2415 Actuator.

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Globe control valve, pneumatically operated Actuator sizes 40 mm - 125 mm, Nominal diameter DN10-65 Kolbengesteuertes Geradsitzventil Antriebsgrößen 40 mm - 125 mm, Nennweiten DN10-65 Vanne à siège droit

More information

Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch

Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety

More information

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation 2/2 way angle seat valve, 3/2 way globe valve 2/2-Wege-Schrägsitzventil, 3/2-Wege-Geradsitzventil Vanne à siège incliné 2/2 voies, vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation 2/2-way angle seat control valve 2/2-Wege-Schrägsitzregelventil Vanne de réglage à siège incliné 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical

More information

Operating Instructions VEGABAR 82. Pressure transmitter with ceramic measuring cell. Foundation Fieldbus. Document ID: 45032

Operating Instructions VEGABAR 82. Pressure transmitter with ceramic measuring cell. Foundation Fieldbus. Document ID: 45032 Operating Instructions Pressure transmitter with ceramic measuring cell VEGABAR 82 Foundation Fieldbus Document ID: 45032 2 Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group...

More information

Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output

Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety 2.1 Authorised

More information

Quick setup guide VEGAPULS 64. Radar sensor for continuous level measurement of liquids ma/hart - two-wire. Document ID: 51462

Quick setup guide VEGAPULS 64. Radar sensor for continuous level measurement of liquids ma/hart - two-wire. Document ID: 51462 Quick setup guide Radar sensor for continuous level measurement of liquids VEGAPULS 64 4 20 ma/hart - two-wire Document ID: 51462 Contents Contents 1 For your safety 1.1 Authorised personnel... 3 1.2 Appropriate

More information

Operating Instructions OPTISWITCH 5200 C, 5250 C with transistor output

Operating Instructions OPTISWITCH 5200 C, 5250 C with transistor output Operating Instructions OPTISWITCH 5200 C, 5250 C with transistor output Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety 2.1 Authorised

More information

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN Pneumatic Controller for Temperature Type 3301 Pneumatic Controller for Temperature Type 301-1 Mounting and Operating Instructions EB 7065 EN Edition January 2014 Definition of the signal words used in

More information

Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output

Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety 2.1 Authorised

More information

Operating Instructions VEGABAR 67

Operating Instructions VEGABAR 67 Operating Instructions VEGABAR 67 4... 20 ma/hart Document ID: 36742 Process pressure/ Hydrostatic Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................

More information

Operating Instructions OPTISWITCH 5200 C, 5250 C with contactless electronic switch

Operating Instructions OPTISWITCH 5200 C, 5250 C with contactless electronic switch Operating Instructions OPTISWITCH 5200 C, 5250 C with contactless electronic switch Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety

More information

Pressure Measurement Fittings

Pressure Measurement Fittings Siemens G 2018 Overview ll shut-off fittings can be secured onto walls, racks (72 mm grid) and vertical and horizontal pipes. This offers the advantage when assembling a plant that the shutoff fittings

More information

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX) Operating Instructions VEGASWING 61, 63 with oscillator SW E60N (EX) Contents Contents Safety information... 2 Note Ex area... 2 1 Product description... 3 2 Function and application... 4 2.1 Principle

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation /- and /3-way angle seat valve /- und /3-Wege-Schrägsitzventil Vanne à siège incliné / et /3 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical

More information

Operating Instructions VEGABAR 83. Pressure transmitter with metallic measuring cell ma/hart. Document ID: 45034

Operating Instructions VEGABAR 83. Pressure transmitter with metallic measuring cell ma/hart. Document ID: 45034 Operating Instructions Pressure transmitter with metallic measuring cell VEGABAR 83 4 20 ma/hart Document ID: 45034 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

Operating Instructions VEGABAR 82. Pressure transmitter with ceramic measuring cell ma/hart. Document ID: 45028

Operating Instructions VEGABAR 82. Pressure transmitter with ceramic measuring cell ma/hart. Document ID: 45028 Operating Instructions Pressure transmitter with ceramic measuring cell VEGABAR 82 4 20 ma/hart Document ID: 45028 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3

More information

Hydrostatic. Overview 192 VEGABAR series VEGAWELL Accessory 200. Hydrostatic VEGABAR series 60 and VEGAWELL

Hydrostatic. Overview 192 VEGABAR series VEGAWELL Accessory 200. Hydrostatic VEGABAR series 60 and VEGAWELL Hydrostatic Overview 192 VEGABAR series 60 194 VEGAWELL 52 198 Accessory 200 Hydrostatic VEGABAR series 60 and VEGAWELL 191 Hydrostatic Level and pressure measurements Measuring principle The pressure

More information

Operating Instructions VEGABAR 67

Operating Instructions VEGABAR 67 Operating Instructions VEGABAR 67 4... 20 ma/hart Document ID: 36742 Hydrostatic Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................

More information

Overview of types. Technical data

Overview of types. Technical data Technical data sheet 6..S+NVFT24-MFT-E Globe valves, 2-way, with flange PN 16, actuator with emergency control function for closed hot water systems up to 150 C in district heating applications approved

More information

Pressure chlorine changeover unit C 7520

Pressure chlorine changeover unit C 7520 BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520

More information

Operating Instructions VEGAMIP T61. Emitting unit. Document ID: 36998

Operating Instructions VEGAMIP T61. Emitting unit. Document ID: 36998 Operating Instructions VEGAMIP T61 Emitting unit Document ID: 36998 2 Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbols used... 4 2 For your safety... 5 2.1

More information

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0 Please read these Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to clutch failure, resulting in damage to other parts. Contents:

More information

Condensate Drain Valve AK 45. Original Installation Instructions English

Condensate Drain Valve AK 45. Original Installation Instructions English Condensate Drain Valve AK 45 EN English Original Installation Instructions 810467-03 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure

More information

SENSOFIT RET 5000 Technical Datasheet

SENSOFIT RET 5000 Technical Datasheet SENSOFIT RET 5000 Technical Datasheet Manual retractable assembly Variable immersion length up to 700 mm With ball valve for easy sensor exchange without process interruptions Bayonet coupling for easy

More information

Operating Instructions VEGABAR 52. Pressure transmitter with CERTEC measuring cell ma. Document ID: 36716

Operating Instructions VEGABAR 52. Pressure transmitter with CERTEC measuring cell ma. Document ID: 36716 Operating Instructions Pressure transmitter with CERTEC measuring cell VEGABAR 52 4 20 ma Document ID: 36716 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism

More information

Pressure measurement. Process pressure VEGABAR 14 VEGABAR 17. Product Information

Pressure measurement. Process pressure VEGABAR 14 VEGABAR 17. Product Information Pressure measurement Process pressure VEGABAR 4 VEGABAR 7 Product Information Contents Contents Description of the measuring principle........................................................... Type overview..............................................................................

More information

Operating Instructions VEGASWING 66. Vibrating level switch for liquids under extreme process temperatures and pressures

Operating Instructions VEGASWING 66. Vibrating level switch for liquids under extreme process temperatures and pressures Operating Instructions Vibrating level switch for liquids under extreme process temperatures and pressures VEGASWING 66 Transistor (NPN/PNP) With SIL qualification Document ID: 44951 2 Contents Contents

More information

Mounting and Operating Instructions EB 5868/5869 EN

Mounting and Operating Instructions EB 5868/5869 EN Electric Control Valves Types 3213/5857, 3213/5824, Types 3214/5824, 3214/3374, 3214/3274 with safety function: Types 3213/5825, 3214/5825, 3214/3374, 3214/3274 Pneumatic Control Valves Types 3213/2780-1,

More information

Bicolour level gauge. Type BU green/red. D-04-B EN-1 Edition 05/11

Bicolour level gauge. Type BU green/red. D-04-B EN-1 Edition 05/11 Bicolour level gauge Type BU green/red D-04-B-16615-EN-1 Edition 05/11 -itable of contents- 1. Health and safety instructions 4-5 1.1 General health and safety instructions...4 1.2 Unit-specific safety

More information

Type overview. R B2 en-gb subject to changes 1

Type overview.  R B2 en-gb subject to changes 1 Technical data sheet R30..-..-..-B2 Characterised control valve, 6-way, Internal thread Two sequences (cooling/heating) with one 90 rotary actuator Switching or modulating control on the water side of

More information

Product information. Differential pressure. Mechanical and electronic differential pressure measurement

Product information. Differential pressure. Mechanical and electronic differential pressure measurement Product information Mechanical and electronic differential pressure measurement VEGADIF 85 VEGABAR 8 VEGABAR 8 VEGABAR 8 VEGABAR 86 VEGABAR 87 Document ID: 65 Contents Contents Measuring principle... Type

More information

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Technical Information Cleanfit CPA471 Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Application Chemical industry Wastewater treatment Plant design Tanks and

More information

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve Self-operated Pressure Regulators Type 41-23 Universal Pressure Reducing Valve ANSI version Application Pressure regulators for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN

More information

Type /2-way globe valve 2/2-Wege-Geradsitzventil Vanne à siège droit 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type /2-way globe valve 2/2-Wege-Geradsitzventil Vanne à siège droit 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 2/2-way globe valve 2/2-Wege-Geradsitzventil Vanne à siège droit 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical changes without notice.

More information

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Self-operated Pressure Regulators Type Universal Excess Pressure Valve Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve Application Pressure regulators for set points from 0.05 to 8 bar Valve nominal sizes DN 15 to 100 Nominal pressure PN 16 to

More information

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66 Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS 06.0001 Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application

More information

Operating Instructions OPTISWITCH 5200 C, 5250 C

Operating Instructions OPTISWITCH 5200 C, 5250 C Operating Instructions OPTISWITCH 5200 C, 5250 C Transistor (NPN/PNP) Document ID: 30432 2 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbols used... 3 2 For your

More information

Pressure relief controller V22 D28

Pressure relief controller V22 D28 Pressure relief controller V22 D28 For heavy oil and high-viscosity media Instructions for Mounting, Start-up and Maintenance SIBC VI.CB.I1.02 Contents 1. General data Page 1.1 Correct application 1 1.2

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation 2/2-way angle-seat control valve 2/2-Wege-Schrägsitzregelventil Vanne de réglage à siège incliné 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical

More information

Operating Instructions VEGASWING 51. Vibrating level switch for liquids. - contactless electronic switch. Document ID: 41045

Operating Instructions VEGASWING 51. Vibrating level switch for liquids. - contactless electronic switch. Document ID: 41045 Operating Instructions Vibrating level switch for liquids VEGASWING 51 - contactless electronic switch Document ID: 41045 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3

More information

Instruction Manual September 2010 SITRANS LVL200S

Instruction Manual September 2010 SITRANS LVL200S Instruction Manual September 200 SITRANS LVL200S Contents Contents About this document. Function.................................. 4.2 Target group.............................. 4.3 Symbolism used............................

More information

Air operated Pinch Valve type VMC

Air operated Pinch Valve type VMC Air operated Pinch Valve type VMC Flange Internal Thread Tri-Clamp Weld-on ends Threaded spigot The flexible modular system for detachable and aseptic piping connections! The ideal solution for isolation

More information

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement Technical Information Cleanfit W CPA450 Retractable assembly for 12 mm sensors for DO/pH/ORP measurement Application Pulp and paper industry Chemical industry Measurement in fibrous or coating media Tanks

More information

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Installation and operating manual Quick closing valve (Bellow sealed) LK product no: LK product no: 902002 Article no: 74506 Revision: 2 Contents 1. General information... 3 2. Safety precautions... 3 2.1 Significance of symbols... 3 2.2 Explanatory notes on safety information... 3 3.

More information

* * Data sheet DA01 VUW (ATEX) Differential pressure measuring device Pressure levels PN250/PN400. Models for use in explosive areas

* * Data sheet DA01 VUW (ATEX) Differential pressure measuring device Pressure levels PN250/PN400. Models for use in explosive areas 09015037 DB_EN_DA01_VUW_ATEX Rev. ST4-A 02/18 *09015037* Data sheet DA01 VUW (ATEX) Differential pressure measuring device Pressure levels PN250/PN400 Models for use in explosive areas DA01... 0A DA01...

More information

Operating Instructions VEGABAR 51

Operating Instructions VEGABAR 51 Operating Instructions VEGABAR 51 4 20 ma Document ID: 36712 Process pressure Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................

More information

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Self-operated Pressure Regulators Type Universal Excess Pressure Valve Self-operated Pressure Regulators Type 41-73 Universal Excess Pressure Valve ANSI version Application Pressure regulator for set points from 0.75 to 400 psi (0.05 to 28 bar) Valves in NPS ½ to 4 (DN 15

More information

Butterfly valves, PN6, PN10, PN16

Butterfly valves, PN6, PN10, PN16 4 131 Butterfly valves, PN6, PN10, PN16 VKF41... Butterfly valves for fitting between counter-flanges Nominal pressures PN6, PN10, PN16 Nodular cast iron GG-20 / GG-25 Metallic tight-closing (end-stop)

More information

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator Pneumatic Control Valve Type 3510-1 and Type 3510-7 Type 3510-1 with 120 cm 2 actuator Type 3510-7 with 120 cm 2 actuator and integrated positioner Type 3510-1 with 60 cm 2 actuator Fig. 1 Pneumatic control

More information

Metso High Consistency Sampler Metso Nove H. Installation & Owner s Manual K10196 V1.1 EN

Metso High Consistency Sampler Metso Nove H. Installation & Owner s Manual K10196 V1.1 EN Metso Nove H Installation & Owner s Manual K10196 V1.1 EN Table of contents Warnings & safety information 3. Actions during operation 19 Recycling and disposal 1. Introduction 7 1.1. General description...7

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

Operating Instructions Process pressure transmitter IPT-1* Vers metalic sensor

Operating Instructions Process pressure transmitter IPT-1* Vers metalic sensor Operating Instructions Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor 4 20 ma/hart Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................

More information

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator Type 3510 Micro-flow Valve In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator DIN version Translation of original instructions Type 3510-1 (left) and Type 3510-7 (right)

More information

2018 High Performance Check Valves for liquid and gaseous media

2018 High Performance Check Valves for liquid and gaseous media 2018 High Performance Check Valves for liquid and gaseous media Check valves Catalogue 45 Date: 04/2018 WEH - We Engineer Hightech All rights reserved, WEH GmbH 2018. Unauthorized copies are strictly forbidden

More information

Operating Instructions VEGACAP 98. Capacitive rod electrode for level detection. - Relay (DPDT) Document ID: 33760

Operating Instructions VEGACAP 98. Capacitive rod electrode for level detection. - Relay (DPDT) Document ID: 33760 Operating Instructions Capacitive rod electrode for level detection VEGACAP 98 - Relay (DPDT) Document ID: 33760 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbols

More information

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves Series 250 Type 3252 1 and Type 3252 7 Pneumatic Control Valves Type 3252 High-pressure valve with Type 3277 Pneumatic Actuator and Type 3767 Electropneumatic Positioner Mounting and Operating Instructions

More information

Operating Instructions VEGABAR 65

Operating Instructions VEGABAR 65 Operating Instructions VEGABAR 65 4 20 ma/hart Document ID: 27531 p Process pressure/ Hydrostatic Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................

More information

57-1. Front door. Tools. Special tools and equipment. T Socket 3320/2 Bit insert for Socket T Assembly tool

57-1. Front door. Tools. Special tools and equipment. T Socket 3320/2 Bit insert for Socket T Assembly tool 57-1 Front door Tools Special tools and equipment T 10011 Socket 3320/2 Bit insert for 3320 3410 Socket T 10034 Assembly tool 57-2 Front door, assembly overview Note: The instrument panel must be removed

More information

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions Technical Information Cleanfit H CPA475 Retractable assembly for ph, ORP measurement under sterile conditions Application Food industry Beverage industry Pharmaceutical industry Drinking water The retractable

More information

Operating Instructions VEGACAP 63. Capacitive rod electrode for level detection. Contactless electronic switch. Document ID: 30009

Operating Instructions VEGACAP 63. Capacitive rod electrode for level detection. Contactless electronic switch. Document ID: 30009 Operating Instructions Capacitive rod electrode for level detection VEGACAP 63 Contactless electronic switch Document ID: 30009 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group...

More information

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal

More information

Hydrostatic. Continuous level measurement. Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194.

Hydrostatic. Continuous level measurement. Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194. Hydrostatic Continuous level measurement Pressure Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194 185 Hydrostatic Level and pressure measurement Measuring principle

More information

Operating Instructions VEGACAL 63. Capacitive rod electrode for continuous level measurement ma/hart - two-wire. Document ID: 30027

Operating Instructions VEGACAL 63. Capacitive rod electrode for continuous level measurement ma/hart - two-wire. Document ID: 30027 Operating Instructions Capacitive rod electrode for continuous level measurement VEGACAL 63 4 20 ma/hart - two-wire Document ID: 30027 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target

More information

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL LILLY ENGINEERING COMPANY 217 CATALPA STREET P.O. BOX 173 ITASCA, ILLINOIS 60143 630-773-2222 FAX: 630-773-3443 www.lillyengineering.com

More information

Starting up hydraulic systems

Starting up hydraulic systems General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable

More information

OPTIFLUX 2000 Quick Start

OPTIFLUX 2000 Quick Start OPTIFLUX 2000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS OPTIFLUX 2000

More information

Operating Instructions. Process pressure transmitter CPT-2x. With SIL qualification Ceramic sensor. Process pressure transmitter CPT-2x

Operating Instructions. Process pressure transmitter CPT-2x. With SIL qualification Ceramic sensor. Process pressure transmitter CPT-2x Operating Instructions Process pressure transmitter CPT-2x 4 20 ma/hart With SIL qualification Ceramic sensor Process pressure transmitter CPT-2x Contents Contents 1 About this document... 4 1.1 Function...

More information

Operating manual Separator

Operating manual Separator Operating manual Separator Sheet no. AS/4.1.141.1.1 issue 20.08.2014 Contents Section Title Page 0 Introduction... 1 1 Intended use......1 2 Marking of the fitting... 1 3 Safety instructions... 2 4 Transport

More information

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves Type 3347-1 and Type 3347-7 Pneumatic Control Valves Type 3347-7, cast body with welding ends Type 3347-7, bar stock body with threaded connections Mounting and Operating Instructions EB 8097 EN Edition

More information

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition July 2007 Contents Contents Page 1 Design and

More information

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve Angle-seat Valve System for continuous control Type 8802/2300 electro-pneumatically operated angle-seat valve + = TWO YEAR WARRANTY on this valve system Burkert 8802 continuous control valve + = 2300 series

More information

Self-operated Temperature Regulators Type 1u Temperature Regulator

Self-operated Temperature Regulators Type 1u Temperature Regulator Self-operated Temperature Regulators Type 1u Temperature Regulator Version according to ANSI Application Temperature regulators for cooling plants Control thermostats for set points 1) from 15 to 480 F

More information

OPTISWITCH 5300 C. Handbook. Vibrating Level Switch. - transistor (NPN/PNP)

OPTISWITCH 5300 C. Handbook. Vibrating Level Switch. - transistor (NPN/PNP) OPTISWITCH 5300 C Handbook Vibrating Level Switch - transistor (NPN/PNP) 2 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbols used... 3 2 For your safety 2.1 Authorised

More information

Product information. Capacitive. Level measurement in bulk solids VEGACAL 62 VEGACAL 65 VEGACAL 66 VEGACAL 67. Document ID: 30139

Product information. Capacitive. Level measurement in bulk solids VEGACAL 62 VEGACAL 65 VEGACAL 66 VEGACAL 67. Document ID: 30139 Product information Level measurement in bulk solids VEGACAL 6 VEGACAL 65 VEGACAL 66 VEGACAL 67 Document ID: 09 Contents Contents Description of the measuring principle... Type overview... 5 Housing overview...

More information

MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS. DP-40-HD series DP-50-HD series DP-80-HD series

MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS. DP-40-HD series DP-50-HD series DP-80-HD series Doc. No. NDP304M-01 MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS DP-40-HD series DP-50-HD series DP-80-HD series WARNING For your own safety, be sure to read these procedures carefully before

More information

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection) Series 42 Self-operated Regulators Type 42-10 RS Check Valve (backflow protection) Application Designed to protect nitrogen and compressed air networks against backflow from directly connected systems.

More information

Power Transmission. Installation and Operating Instructions for Brake Caliper DV / DH 020 FKM. E e.

Power Transmission. Installation and Operating Instructions for Brake Caliper DV / DH 020 FKM. E e. Power Transmission Installation and Operating Instructions for Brake Caliper DV / DH 020 FKM Schaberweg 30-34 Telephone +49 6172 275-0 61348 Bad Homburg Telefax +49 6172 275-275 Germany www.ringspann.com

More information

Operating Instructions VEGADIS 61

Operating Instructions VEGADIS 61 Operating Instructions VEGADIS 61 Indication and adjustment Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group.............................. 4 1.3

More information

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator

In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator Type 3510 Micro-flow Valve In combination with an actuator, e.g. a SAMSON Type 3271 or Type 3277 Pneumatic Actuator ANSI version Translation of original instructions Type 3510-1 (left) and Type 3510-7

More information

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321 Valve Series V2001 Globe Valve Type 3321 Fig. 1 Type 3321 Valve with mounted rod-type yoke for pneumatic or electric actuators (partial view) Mounting and Operating Instructions EB 8111/8112 EN Edition

More information

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution Medium Voltage Distribution PIX Withdrawable Voltage Transformer Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual Nr. Edition 11/2011 www.schneider-electric.com Schneider

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

Operating Instructions VEGASWING 51. Vibrating level switch for liquids. - transistor (PNP) With extended status indication. Document ID: 40552

Operating Instructions VEGASWING 51. Vibrating level switch for liquids. - transistor (PNP) With extended status indication. Document ID: 40552 Operating Instructions Vibrating level switch for liquids VEGASWING 51 - transistor (PNP) With extended status indication Document ID: 40552 Contents Contents 1 About this document 1.1 Function... 3 1.2

More information

26 Series Stainless Steel 2-way Ball Valves

26 Series Stainless Steel 2-way Ball Valves 1-800-899-0553 26 Series Stainless Steel 2-way Ball Valves Users Manual Installation, Operation, & Maintenance 1. General Precaution 1.1. Material Section Material deterioration is determined by the contained

More information

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL BUTTERFLY VALVE 31300 SERIES INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE 1. Overview Read these instructions carefully before starting the valve installation and start-up work. Safe keep the instructions

More information

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: ) EN Instructions for Fitting, Operating and Maintenance Canopy Door 1 818 012 RE / (St.: 12.2010) 12.2010 ENGLISH Contents 1 Safety Instructions... 3 1.1 Qualified persons... 3 1.2 Symbols and signal words

More information