Electronics Grounding Tester GT4. EN - Instruction Manual. Issue/Rev (05/15) MN E DOK-553. The Most Trusted Name In Measurement

Size: px
Start display at page:

Download "Electronics Grounding Tester GT4. EN - Instruction Manual. Issue/Rev (05/15) MN E DOK-553. The Most Trusted Name In Measurement"

Transcription

1 === Ende der List e f ür T ext mar ke I ntro === Pos : 2 /T ec hdoc /Seni ng/intr o's/erste Seite/Intro: GroundingT ester-gt @ 1 EN - Instruction Manual Electronics Grounding Tester GT4 Issue/Rev (05/15) MN E DOK-553 The Most Trusted Name In Measurement

2 Pos : 4 /T ec hdoc /Seni ng/hist orie-hinweis-dokumente/dok-553_groundingt ester-gt @ 1 Pos : 5 /T ec hdoc /Seni ng/allgemein/ FÜ1---> Inhal ts verzeic hnis (Deutsc @ 1 Grounding Tester GT4 General MN E DOK-553 Issue/Rev (05/15) Further documentation for this product: Description Order No. none History Revision Date Editor Status Description Rev August 2013 TK / jp / elf released first edition Rev February 2014 TK / jp released new Layout Rev April 2014 TK / jp released new Drawing (Fig. 9: ) 2 The Most Trusted Name In Measurement

3 === Ende der List e f ür T ext mar ke I nhalts verz eichnis === MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 General Table of Contents (English) Table of Contents (English) 3 1 General Orientation aids for the manual General Description Use and marking Technical parameters common for all designs Technical parameters Technical parameters for UZCL 3.n Operating instructions Function description Usage GT4 for tanker vehicles Usage GT4 for railway tanks Usage GT4 for mobile use Procedure of vehicle connection with earthing point Error states Electrical connections Setting of the sensed tank type Connection to a PC Control program Installation After start Setting of evaluation limits Value on the converter Status indication Setting of parameters Clamps connection Behaviour of the green indicator Communication port Refreshing the parameters Termination of work with the program Interrupting communication between the Earthing-testing block and PC Control over Display unit EDA Using Display unit EDA for Earthing-testing block GT4, UZCL Description of item MENU for Earthing-testing block GT4, UZCL PARAMETERS The Most Trusted Name In Measurement 3

4 Pos : 7 /T ec hdoc /Seni ng/allgemein/ 1---> 1 Grounding Tester GT4 General MN E DOK-553 Issue/Rev (05/15) 5 Installation Mechanical mounting Mechanical installation procedure Electrical connections Installation procedure for GT Commissioning Setup Testing Treatment of boxes for GT Maintenance 28 8 Service 30 9 Warnings Warnings when handling Ordering information 31 Approvals EC-Declaration of Conformity The Most Trusted Name In Measurement

5 Pos : 9 /T ec hdoc /Seni ng/00-t echnisc heinfor mati on/dok-553_gr ounding-tester / 1---> Gener al Descripti 1 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 General 1 General Pos : 8 /T ec hdoc /Seni ng/allgemein/2: Orientier ungshilfen + Pi Orientation aids for the manual We have provided some orientation aids so that you can easily find the necessary information in this manual. The information in this manual ranges from imperative safety procedures and standardized guidelines through to concrete handling procedures and advice. To differentiate these more easily, the information is marked with corresponding pictograms in front of the relevant text. These are intended not just to draw particular attention to these passages, but also to make it easier to find the information you want. Therefore the pictograms are symbolic of the underlying textual content. The following pictograms are used in this manual: Danger sign Danger of explosions caused by easily ignited gases and liquids here. Risk of operating fault Actions that may damage the equipment. Legal notice Actions that may have legal consequences. Working step Concrete action statements, e.g.: Press the <Enter> key. Input necessary e.g. via numeric or function keys. Positive response message e.g. The main menu now appears Negative response message e.g. If a fault message appears now... Background information Short-Tip, e.g. See more detailed information in chapter XX. Option Special case. Function Functional description. NOTE: indicates a special situation. ATTENTION: particular attention is to be paid. The Most Trusted Name In Measurement 5

6 Pos : 12 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/ 1---> Tec hnical parameters c ommon for all 1 Grounding Tester GT4 General Description MN E DOK-553 Issue/Rev (05/15) 2 General Description Pos : 10 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/general D @ 1 The GT4 Earthing-testing block is designed for safe pumping of fuels into tank trucks or railway tanks in areas with the danger of flammable gases and dusts explosion. The EGT design with flameproof enclosure has an aluminium finished casting. Marking of Earthing-testing blocks is in detail described in "Ordering information" / p. 31. Pos : 11 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: U se and mar ki Use and marking 4 flameproof enclosure, IP 65, 1 clamp Table 1: Type of Earthing-testing block box protection The equipment serves: to test the system, consisting of a tanker and filling/discharging point to earth the tanker with regard to static electricity via a defined resistance (100kΩ) to check that the clamps of the Earthing-testing block are correctly connected to the tanker The tanker is connected to the equipment by clamps with a cable with maximum length of 20 m. The Earthing-testing block monitors three connection states of earthing clamps, namely whether the tanker is connected correctly, connection to the earth point of the building and status when the clamps are not connected at all. The equipment also monitors individual successions of these states. When the clamp is connected to a tanker, the tanker is always earthed in terms of electrostatic charge. It does not matter which indicator is on. 6 The Most Trusted Name In Measurement

7 Pos : 16 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/ 1---> Oper ating i nstr ucti 1 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Technical parameters common for all designs 3 Technical parameters common for all designs Pos : 13 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/t ec hnic al par ameters common for all @ 1 Manufacturer: Power supply: Power input: Clamps: FMC Technologies, Inc. 20V DC V/50 Hz 10 VA pressed galvanized steel, contact point copper Supply connection: ÖLFLEX 540 P 3Gx2,5 1) Supply connection: H07RN-F 3Gx1,5 cable 3) Output connection: ÖLFLEX 540 P 3Gx2,5 1) Output connection: Output connection: Cable glands Maximum length of output cable Output circuits: spiral cable ÖLFLEX 540 P 3Gx2,5 2) retracting cable reel (specifications and use only on inquiry) for cable diameter 6.1mm to 11.7mm 20m 2x switching contact 230 V/3A 1) Temperature range -50 C to +60 C* ) 2) Temperature range -30 C to +60 C 3) Temperature range -20 C to +40 C * decreased possibility of cable dynamics for temperatures lower than -40 C Pos : 14 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: Tec hnical Technical parameters Protection IP 65 Mass 12 kg Operation temperature -50 to 60 C 4),5) Storage temperature -50 to 60 C Protective environment II 2G Ex d [ib] IIB T4 Gb * For temperature lower than -40 C keep the device always switched on. Pos : 15 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: Tec hnical parameters for UZC L Technical parameters for UZCL 3.n Protection IP 65 Mass 6 kg Operation temperature -20 to 40 C 4),5) Storage temperature -20 to 40 C Protective environment II 3(2)G Ex nac ib [ib] IIC T4 Gb The Most Trusted Name In Measurement 7

8 Grounding Tester GT4 Operating instructions MN E DOK-553 Issue/Rev (05/15) 4 Operating instructions Pos : 17 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: Functi on descri Function description Usage GT4 for tanker vehicles When in operation the Earthing-testing block monitors two earthing components impedance component and ohmic component. If the value is in the range 50 Ω to 3000 Ω, the electronics evaluate the system to be correct with regard to electrostatic discharge and the green indicator is on. If the monitored impedance value is less than 50 Ω the Earthing-testing block evaluates this status as a direct connection between the clamps and the terminal s earthing system and the red indicator is on. This condition serves to eliminate incorrect connection of the Earthing-testing block when the clamps are, for instance, directly connected to the terminal s steel structure. The status of the Earthing-testing Block is indicated by the signaling elements on the front panel of the instrument. The Earthing-testing Block can be in the following states: 1. The tanker is not connected or does not meet the condition that the impedance <3000Ω the red indicator is on 2. The earth clamps are directly connected to the earthing point of the structure - the red indicator is on 3. The tanker is connected and the impedance is in the range 50 Ω to 3000 Ω- the green indicator is on or is flashing according to user setting. 4. The earth clamps are connected directly to the earthing point of the structure after being connected to the tanker - the green indicator is on. Relays RE1 and RE2 are assigned to clamp K1. Relays RE3 and RE4 are assigned to clamp K2. Output relay - is switched on only in the case as described in points 3. and 4., when the green indicator is on or flashing. Point 4 describes the condition when the tanker is earthed via the Earthing-testing block and afterwards it is conductively connected earthing point of the structure, for example via filling arm Usage GT4 for railway tanks Only two states apply for railway tanks. 8 The Most Trusted Name In Measurement

9 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Operating instructions 1. The tanker is not connected or does not meet the condition that the impedance <3000Ω the red indicator is on. 2. The tanker is connected and the impedance of the system is in the range 0 Ω to 3000 Ω- the green indicator is on. 3. Output relay - is switched on only in the case as described in point 2, when the green indicator is on or flashing Usage GT4 for mobile use A vehicle is connected to the earthing point of the structure by means of clamps with supply cable of maximum 20 m length. It is proper to furnish the vehicle with a reel for clamps supply cable. The clamps are provided with two contacts, the first contact is for detection of vehicle connection with earthing point of the structure and safe discharge of vehicle electrostatic load. The second contact is for direct connection of vehicle frame with earthing point of the structure. The second contact is activated only after safe discharge of electrostatic load. The clamps can be connected to the earthing point also in zone I Procedure of vehicle connection with earthing point Red indicator is on the Earthing-testing block, the clamps are not connected to the earthing point of the structure. Connect the clamps to the earthing point of the structure; the green indicator will start to flash. Electrostatic load of vehicle is discharging. After discharge of the vehicle electrostatic load the second contact of the clamps is activated, the green indicator is on it is possible to start work. After the work is finished, disconnect the clamps from the earthing point of the structure Error states If the second contact of clamps is disconnected from the earthing point during work, the green indicator will start to flash. The vehicle is however still protected from the electrostatic load point of view. After correction the green indicator is on. If the first contact of the clamps is disconnected from the earthing point, the green indicator is still on. The vehicle is firmly connected through the second clamp contact with the earthing point. And it is still protected from the electrostatic load point of view. If both clamps contacts are disconnected from the earthing point during work, the green indicator will go off and the red indicator will turn on. The vehicle at this moment is not protected from the The Most Trusted Name In Measurement 9

10 Grounding Tester GT4 Operating instructions MN E DOK-553 Issue/Rev (05/15) electrostatic load point of view and is not connected with the earthing point. Pos : 18 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: El ectrical connec Electrical connections Fig. 1: The connection terminals on the PCB Note: the relay outputs RE3 and RE4 are not used in versions GT4! Connector XC1 Name Power Supply Terminal number 1 L 2 E Lead 3 PE 4 PE 5 PE Table 1: Description of XC1 connector Connector XC2 Name RE2 Terminal number Lead 1 NO 2 COM 3 NC Table 2: Description of XC2 connector 10 The Most Trusted Name In Measurement

11 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Operating instructions Connector Name Terminal number Lead 1 Earth clamps 1 XC3 Clamps 2 Earthing point of structure 3 not used for GT4 Table 3: Description of XC3 connector Connector XC4 Name RE1 Terminal number Lead 1 NC 2 COM 3 NO Table 4: Description of connector XC4 Pos : 19 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: Setti ng of the s ens ed tank Setting of the sensed tank type DIP switch with XC5 reference located to the right from XC3 connector is used for setting of the sensed tank type. The setting is done as per the following table. Clamp Switch1 Switch2 Switch3 Tanker vehicles OFF OFF ON Railway tanks OFF ON OFF Bag ON OFF ON Off OFF OFF OFF Table 5: Setting of the sensed tank type The Most Trusted Name In Measurement 11

12 Grounding Tester GT4 Operating instructions MN E DOK-553 Issue/Rev (05/15) Fig. 2: Setting of the sensed tank type Pos : 20 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: C onnecti on to a Connection to a PC In order to connect the system to a PC, the communication module for IrDA interface must be used. The IrDA LED s are situated in the red indicator. The maximal distance for safety communication is 1m. The communication modules for IrDA interface are accessories and they can be ordered separately. You can find more accessories in "Ordering information" / p. 31. Fig. 3: The communication module for IrDA interface, type USBIR 1 12 The Most Trusted Name In Measurement

13 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Operating instructions Pos : 21 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: C ontrol pr Control program The control program is used to setup the parameters, reading the current status and values of the A/D converter of the Earthing-testing block. Setup parameters: 1. Upper evaluation value 2. Bottom evaluation value 3. Connection of the clamps 4. Flashing when tanker is connected 5. Communication port 6. RE1,RE2, RE3 and RE4 blocking 7. Mobile use Status: 1. Not earthed 2. Earthed 3. Tanker connected 4. Tanker earthed Installation 1. Locate the F:\EGT_3 directory and double click setup.exe (Where F is CD-ROM) to start the application. 2. Select OK to continue the installation The Most Trusted Name In Measurement 13

14 Grounding Tester GT4 Operating instructions MN E DOK-553 Issue/Rev (05/15) 3. Select Change Directory to create a new program directory. 4. Select button to continue installation 5. Click Continue. 6. Click OK to finish installation After start After the program is started, evaluation limits, values on converters, setting of parameters and the current status of the Earthing-testing block are loaded. According to the current state the red or green indicator lights up above the status line and current status of the Earthing-testing block is shown in the status line Setting of evaluation limits The evaluation limits can be set by entering the values in the respective boxes and clicking the button above the box Upper limit or Lower limit. The evaluation limits must always be set within the range of 7 to 225 converter points Value on the converter The value on the converter is displayed in the Converter window. It has a value in the range of 0 to 255. This value cannot be altered, it is only informative. 14 The Most Trusted Name In Measurement

15 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Operating instructions Indicators Setting of evaluation limits Status line AD Converter value Button for refreshing of parameters Selection of communication port Parameters UZCL Button for program termination Fig. 4: Control program Windows Status indication The red and green indicators and the status box are used to indicate the status. The behavior of the indicators is described in section 3.2. The current status of the Earthing-testing block is shown in the status box, see above Setting of parameters Clamps connection By ticking the Clamps connected box evaluation of the given clamp states is activated. When the box Clamps connected is not ticked, The Most Trusted Name In Measurement 15

16 Grounding Tester GT4 Operating instructions MN E DOK-553 Issue/Rev (05/15) the GT4 will not evaluate the status of the grounding clamps and the corresponding indicators will not be active. Similarly the indicators on the front panel of the GT4 for the given clamps will not be active Behaviour of the green indicator The green indicator will flash when a tanker is connected and the Flash when tanker connected box is ticked. If this box is not ticked the green indicator will be only on Communication port The communication module for IR communication connects to a PC via RS232 interface. The port can be selected using the options in the bottom part of the window to the right of the Refresh button Refreshing the parameters Refreshing the parameters is done by clicking the Refresh button. By doing this all parameters will be read as when the program is started Termination of work with the program Button End is intended for termination of the work with the program Interrupting communication between the Earthingtesting block and PC When communication between the GT4 and PC is interrupted the information panels become inactive. When communication is restored the panels will be reactivated. See the following picture. Fig. 5: Interrupted communication between PC and UZCL 16 The Most Trusted Name In Measurement

17 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Operating instructions Pos : 22 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: C ontrol over Dis play unit ED Control over Display unit EDA Fig. 6: Display unit EDA d.n Display unit EDA is intended for monitoring and controlling equipments in explosive environments - zone 1. The unit is located in Ex certificated plastic box. There is an inspection hole for IrDA interface on the bottom side of the box. The unit is powered from 2xAA Duracell Plus Alkaline 1.5V. The unit consists of a keyboard, graphic display, RAM to storage data, a real time clock, IrDA interface and a connector for RS232 / RS485 interface. The Most Trusted Name In Measurement 17

18 Grounding Tester GT4 Operating instructions MN E DOK-553 Issue/Rev (05/15) Using Display unit EDA for Earthing-testing block GT4, UZCL The initial screen is shown after start. The current data are displayed after successful connection to Earthing-testing unit. Fig. 7: Initial screen with current data GT4, UZCL Status description: Converter 1 value from AD converter for clamp 1 Converter 2 value from AD converter for clamp 2 Clamp 1 clamp status 1: Ungrounded, clamp 1 is not connected to a grounded object Grounded, clamp 1 is connected to a grounded object A tanker is connected, clamp 1 is connected to the tanker A tanker is grounded, clamp 1 is connected to the tanker that has been grounded Clamp 2 clamp 2 status: Ungrounded, clamp 2 is not connected to a grounded object Grounded, clamp 2 is connected to a grounded object A tanker is connected, clamp 2 is connected to the tanker A tanker is grounded, clamp 2 is connected to the tanker that has been grounded 18 The Most Trusted Name In Measurement

19 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Operating instructions Description of item MENU for Earthing-testing block GT4, UZCL Folder MENU contains two items: PARAMETERS and SETTING PARAMETERS The item PARAMETERS enables read, write, edit and save parameters from internal memory or from Earthing-testing block. Folder PARAMETERS contains four items: Read reading parameters from Earthing-testing block GT4, UZCL Write writing parameters to Earthing-testing block GT4, UZCL Edit editing parameters Load loading parameters from internal memory of unit EDA. This folder contains two items. Initial or last saved parameters can be loaded from memory. Memory last saved parameters Default initial parameters Save save parameters to internal memory of unit EDA If any parameters are not load from Earthing-testing block GT4, UZCL ( Read ) or from internal memory of unit EDA ( Load ) items Write, Edit and Save will not be enabled. Fig. 8: Loaded parameters of Earthing-testing block EGT, UZCL Following Earthing-testing block parameters can be set: Page 1: Min limit 1 lower evaluation limit for clamp 1. Max limit 1 upper evaluation limit for clamp 1. Min limit 2 lower evaluation limit for clamp 2. Max limit 2 upper evaluation limit for clamp 2. The Most Trusted Name In Measurement 19

20 Pos : 23 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/ 1---> Installati 1 Grounding Tester GT4 Installation MN E DOK-553 Issue/Rev (05/15) Page 2: Config Byte The value cannot be edited, it changes according to the following parameters: Clm 1 Clamp 1 connected to GT4, UZCL. Clm 2 Clamp 2 connected to GT4, UZCL. EFl 1 Flashing while a tanker is connected by clamp 1. EFl 2 Flashing while a tanker is connected by clamp 2. D Clm Twin clamp 5 Installation Pos : 24 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/ins tall @ 1 When mounting, operating and maintaining the electrical Earthing-testing block the stipulated valid standards and safety regulations must be adhered to. Pos : 25 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: M ec hanic al mounti Mechanical mounting The box of the Earthing-testing block is mounted in a vertical position, so that the operator can see the indicators when earthing vehicles. Pos : 26 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: M ec hanic al installati on pr Mechanical installation procedure Boxes for GT4 are flameproof using four M10 bolts with connecting dimensions according to Fig. No. 1.1, 1.2. When a clamp holder is used, connecting holes according to Fig. 9: Installation with clamp holder are used. 20 The Most Trusted Name In Measurement

21 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Installation Fig. 9: Installation with clamp holder The Most Trusted Name In Measurement 21

22 Grounding Tester GT4 Installation MN E DOK-553 Issue/Rev (05/15) Pos : 27 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: El ectrical connec tions Electrical connections The connections are made according to the electrical wiring diagram drawing no , EPR for version GT4. For correct function of the earthing element it is essential that the PE lead (terminal 3 or 4 on terminal box XC1 Power supply ) is connected to the frame of the bridge. In case of improper local earthing it is possible to connect terminal 4 of terminal box XC1 Power supply to the earthing point for correct operation of the earthing block. Without this connection GT4 may not operate properly. Pos : 28 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: Installati on pr ocedure for EGT Installation procedure for GT4 1. Put a power cable through cable gland no.1 into flameproof enclosure 22 The Most Trusted Name In Measurement

23 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Installation 2. Connect power cable leads in terminal box XC1. Connect brown lead in terminal L (no. 1), blue lead in terminal N (no. 2), yellow-green in terminal PE (no. 3). Tighten the cable gland no. 1 when connection is complete. 3. Put the two-lead control cable through cable gland no. 2. This cable uses one switching relay contact. The Most Trusted Name In Measurement 23

24 Grounding Tester GT4 Installation MN E DOK-553 Issue/Rev (05/15) 4. Connect the control cable to connector XC2 or XC4. After connection of the cable into terminal box XC2 or XC4 tighten the cable gland. Examples of the relay switching contacts connection are shown below. Examples of the relay contact connection one switching Fig. 10: Examples of the relay one switching contact connection 5. If you use both switching contacts of the relay, bring the four-lead control cable through cable gland no. 2 to terminal box XC2 and XC4. 24 The Most Trusted Name In Measurement

25 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Installation 6. Connect the control cable to terminal boxes XC2 and XC4. After connection of the cable to terminal boxes XC2 and XC4 tighten the cable gland No. 2. Examples of relay switching contacts connections are shown below. Fig. 11: Examples of relay both switching contacts connection 7. Connect external earthing point of flameproof enclosure to an earthed part (frame) of the fuel depot by means of the yellow-green lead (1mm 2 diameter). 8. Close the flameproof enclosure and tighten with 8 screws M10 x 25. All screws of the must be properly tightening! Recommended strength to tighten the screws is Nm. The Most Trusted Name In Measurement 25

26 Pos : 29 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/elec tric c onnecti on, dr.no ,EPR / GT 1 Grounding Tester GT4 Installation MN E DOK-553 Issue/Rev (05/15) Fig. 12: Electric connection, dr.no ,EPR / GT4 26 The Most Trusted Name In Measurement

27 Pos : 34 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/ 1---> Mai 1 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Commissioning Pos : 30 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/ 1---> Commissi oni Commissioning Pos : 31 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: Setup All parameters of the Earthing-testing block are setup using the control software. The parameters can only be set after the power supply has been connected. Prior to commissioning it is necessary to first set the range for the upper and lower evaluation limits! Without these limits the Earthing-testing block will not function correctly. This setting is made during manufacture. During installation on location, the upper and lower evaluation limits are altered by means of the PC program to suit local conditions. Pos : 32 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: Tes Testing During testing it is necessary to simulate all the situations that can occur during operation. It concerns the following situations: 1. The clamps are connected to an earthed object 2. The clamps are not connected to an earthed object, the operator is holding them. 3. The clamps are connected to the tanker, which is then earthed without disconnecting the clamps. 4. Calibration of the evaluation limits using the button and control software. Pos : 33 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: Treatment of boxes for Treatment of boxes for GT4 Explosion proof boxes ELPZ for Earthing-testing blocks are explosion proof fixed enclosures, which must have all bolts properly tightened during operation. Recommended strength to tighten the screws is Nm. The Most Trusted Name In Measurement 27

28 Grounding Tester GT4 Maintenance MN E DOK-553 Issue/Rev (05/15) 7 Maintenance Pos : 35 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/m aintenanc @ 1 Preventative checks are performed according to the requirements of operation, however at least every 6 months. The quality of all mechanical connections and contacts is checked and setting of evaluation limits for testing of connected impedance. The condition of box and cable glands has to be checked at least once a year. Dust and dirt have to be removed from box surface. Preservation of the connection areas of the box in design of Flameproof enclosure has to be restored once a year. Recommendation: If during cover installation misalignment of openings for fixing bolts between the bottom and the cover occurs, release 4 bolts on hinges (by about 2 turns). This will enable correct cover seating and bolting with the bottom. After tightening of main bolts tighten also the bolts of the hinges. Fuses: FU1, FU4, FU5 FU5 FU2 T100mA T160mA T63mA Servicing of the equipment can only be performed by the manufacturer or persons trained by the manufacturer. If during maintenance or inspection any damage occurs, it is necessary to put the instrument immediately out of operation and let it repaired by the manufacturer. The instrument must be put out of operation if: there is mechanical damage, which prevents correct function its parts are damaged by deep corrosion name plate of manufacturer is missing or if data on the name plate are illegible the cable, pliers, earthing conductor or connecting cable is damaged If the pliers are damaged, they can be replaced directly by the customer. When replacing the pliers follow the following procedure: Order spare pliers together with parts necessary for the replacement - order no.: The Most Trusted Name In Measurement

29 Pos : 36 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/ 1---> S er 1 MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Maintenance Snip the pliers off close the black sleeving which covers the connection of pliers with cable. Put larger blow-in sleeving on the cable Pull the cable through pliers opening so as its free end has 200 mm and the sleeving is behind the pliers Insert smaller blow-in sleeving on the free end After previous stripping of the conductors (in the length of 20 mm) press cable eye on the free part of the cable and insert the smaller blow-in sleeve on the stripped conductors so as the sleeve covers the whole part of the stripped conductors up to the cable eye. By means of hot air gun attach the sleeve to the cable Insert the cable eye on pliers screw and tighten it. Finally insert the large blow-in sleeve on the pliers so as ¾ is on the pliers and ¼ on the cable Attach the sleeve by hot air gun (Fig. 13: Pliers). Fig. 13: Pliers When servicing and maintenance of equipment is recommended to use the size of torques for bolts and nuts according to the table: Torque (Nm) strength brass size M6 6,4 9,7 3,2 M8 16,1 24,5 8,0 M10 31,8 48,4 15,9 The Most Trusted Name In Measurement 29

30 Pos : 38 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/ 1---> Warni 1 Pos : 40 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/ 1---> Ordering i nformati 1 Grounding Tester GT4 Service MN E DOK-553 Issue/Rev (05/15) 8 Service Pos : 37 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/ser vic @ 1 Company FMC Technologies provides warranty as well as after-warranty service for the given instrument. In case of reel or cable damage contact the manufacturer or corresponding sales representative. Name and address of the manufacturer: Smith Meter GmbH Regentstrasse 1 D Ellerbek Tel.: (Switchboard) Fax: (Service) info.ellerbek@fmcti.com Web: 9 Warnings Pos : 39 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/2: Warni 5\mod_ _19.doc Warnings when handling Prior to opening the Earthing-testing block in explosive environment it must be disconnected from the power supply and wait for one minute. 30 The Most Trusted Name In Measurement

31 Pos : 41 /T echd OC/Seni ng/00-tec hnisc heinfor mation/d OK- 553_Groundi ng-tester/ordering infor mati @ 1 === Ende der Liste für T extmar ke Inhalt === MN E DOK-553 Issue/Rev (05/15) Grounding Tester GT4 Ordering information 10 Ordering information Type Protection Protective environment GT4 IP65 II 2G Ex d [ib] IIB T4 GT4 for mobile use IP65 II 2G Ex d [ib] IIB T4 National version UK Czech republic Poland Slovakia Germany Russia Type of the cable to the clamp Temperature range Ölflex Classic 540 P 3 G 2,5 - PUR, 10m -50 C to 60 C Ölflex Classic 540 P 3 G 2,5 - spiral PUR, 10m -30 C to 60 C Cable reel -20 C to 60 C Accessories Twin clamp Clamp holder Calibration set for RS232 interface till serial number 129/06/06 Calibration set for IrDA interface since serial number 129/06/06 * The maximum length of cable is 20m The Most Trusted Name In Measurement 31

32 Grounding Tester GT4 Ordering information MN E DOK-553 Issue/Rev (05/15) Index. A address C Clamps communication module control program converter D DIP switch E earthing point... 8, 9 Earthing-testing... 6, 8, 19, 29 Earthing-testing block 9, 13, 14, 15, 19, 21, 33 EC-Declaration of Conformity EDA electrostatic discharge... 8 electrostatic load... 9 electrostatic load point... 9 ELPZ explosive environment F flameproof... 6, 23 G GT4... 6, 8, 9, 16, 21, 23 I impedance... 8 indicators IrDA interface... 12, 17 IrDA LED s M maintenance... 30, 31 Mass... 7 O Operation temperature... 7 outputs P PARAMETERS PC program pictograms... 5 pliers Protective environment... 7 R railway tanks... 6, 8 RS232 / RS RS232 interface S sensed tank type Storage temperature... 7 T Technical parameters common for all designs... 7 testing MN E DOK-553 Issue/Rev (05/15) Sening is a registered trademark of FMC Technologies

33 === Ende der List e f ür T ext mar ke Zeic hnungen === Pos : 43 /T echd OC/ Seni ng/eg- Konfor mit äts er klär ungen/ FZ1---> @ 1 Approvals Pos : 44 /T echd OC/ Seni ng/eg- Konfor mit äts er klär ungen/at EX_SM_KEel _250_Grounding _Tester _GT @ 1 EC-Declaration of Conformity The Most Trusted Name In Measurement MN E DOK-553 Issue/Rev (05/15) 33

34 Pos : 46 /T echd OC/ Seni ng/intro's/ Letzt e Sei te/i ntro: SENIN GVertriebAdr ess @ 1 === Ende der List e f ür T ext mar ke I ntro_letzt eseit e === The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. Contact information is subject to change. For the most current contact information, visit our website at and click on the Contact Us link in the left-hand column. Headquarters: 500 North Sam Houston Parkway West, Suite 100 Houston, TX USA, Phone: +1 (281) , Fax: +1 (281) Measurement Products and Equipment: Erie, PA USA +1 (814) Ellerbek, Germany +49 (4101) 3040 Barcelona, Spain +34 (93) Beijing, China +86 (10) Buenos Aires, Argentina +54 (11) Burnham, England +44 (1628) Dubai, United Arab Emirates +971 (4) Los Angeles, CA USA +1 (310) Melbourne, Australia +61 (3) Moscow, Russia +7 (495) Singapore Visit our website at Printed in Germany 05/15 F. A. Sening GmbH, Inc. All rights reserved. MN E / DOK-553 Issue/Rev (05/15) Integrated Measurement Systems: Corpus Christi, TX USA +1 (361) Kongsberg, Norway +47 (32) San Juan, Puerto Rico +1 (787) Dubai, United Arab Emirates +971 (4)

Electronic Preset Delivery System Smith Meter AccuLoad III. Vapor Recovery. Vapor Recovery System. Overview

Electronic Preset Delivery System Smith Meter AccuLoad III. Vapor Recovery. Vapor Recovery System. Overview Electronic Preset Delivery System Smith Meter AccuLoad III Vapor Recovery Issue/Rev. 0.0 (5/11) Bulletin AB06073 Vapor Recovery System In AccuLoad III.net firmware revision 11.16, a new feature was implemented

More information

Densitometers L-Dens 427F Ex Density Sensor Specifications

Densitometers L-Dens 427F Ex Density Sensor Specifications Issue/Rev. 0.1 (2/12) Densitometers L-Dens 427F Ex Density Sensor Specifications Bulletin SS04001E The L-Dens 427F Ex Density Sensor combines an accuracy of 1 x 10-4 g/cm 3 in a compact design. Continuous

More information

Smith Meter AccuLoad III AccuLoad III-S and N4 Hardware Worksheet

Smith Meter AccuLoad III AccuLoad III-S and N4 Hardware Worksheet Electronic Preset Delivery System Smith Meter AccuLoad III AccuLoad III-S and N4 Hardware Worksheet Issue/Rev. 0.2 (9/07) Bulletin AB06050 This worksheet is being provided to ensure that the AccuLoad III-S

More information

Form No. P Meter, PD Model SD, ASD, SF, or ASF-4, 4R, 4V, or 4RV-NF Parts List

Form No. P Meter, PD Model SD, ASD, SF, or ASF-4, 4R, 4V, or 4RV-NF Parts List Form No. P0541.03 Meter, PD Model SD, ASD, SF, or ASF-4, 4R, 4V, or 4RV-NF Parts List Issue/Rev. 0.3 (3/01) Bulletin P0541.03 SD and ASD Models The Most Trusted Name In Measurement SD or ASD SF or ASF

More information

Tools, Mechanical. All or Multiple Products. Parts List. Feeler Gauges. Spiders and Bushings. Feeler Gauge Extension Rod. Cam Setting Bushing

Tools, Mechanical. All or Multiple Products. Parts List. Feeler Gauges. Spiders and Bushings. Feeler Gauge Extension Rod. Cam Setting Bushing Issue/Rev. 0.1 (9/12) All or Multiple Products Tools, Mechanical Parts List Bulletin PO0A001 Spiders and Bushings Feeler Gauges Locates rotor assembly while obtaining blade tip and block clearances on

More information

OrificeMaster Specifications

OrificeMaster Specifications Issue/Rev. 0.2 (10/06) Single Chamber Orifice Fittings OrificeMaster Specifications Bulletin SSOR005 FMC Technologies Measurement Solutions Orifice- Master Single Chamber Orifice Fitting is manufactured

More information

Additive Injectors. AccuPlus. Maintenance. The Most Trusted Name In Measurement

Additive Injectors. AccuPlus. Maintenance. The Most Trusted Name In Measurement Additive Injectors AccuPlus Issue/Rev. 0.0 (11/12) Maintenance Bulletin MN05003E The Most Trusted Name In Measurement Caution The default or operating values used in this manual should not be construed

More information

Pump Delta2. US - Operating Instructions. Issue/Rev (08/12) MN F US DOK-490E. Sening is a registered trademark of FMC Technologies

Pump Delta2. US - Operating Instructions. Issue/Rev (08/12) MN F US DOK-490E. Sening is a registered trademark of FMC Technologies Pos : 2 /T ec hdoc /Seni ng/intr o's/erste Seite/Intro: Delta2Pumpe2 @ 0\mod_1311240690894_19.docx @ 11906 @ 0 @ 1 === Ende der Liste für T extmar ke Intro === US - Operating Instructions Issue/Rev. 1.01

More information

PRIME 4 Service. Smith Meter Rotary Vane Meters. Contents

PRIME 4 Service. Smith Meter Rotary Vane Meters. Contents Smith Meter Rotary Vane Meters PRIME 4 Service Issue/Rev. 0.4 (7/11) Bulletin MN01041 Contents Trouble Shooting... Page 2 Genuine Smith Meter Parts... Page 2 Special Tools and Fixtures... Page 2 Disassembly

More information

Smith Meter TM Turbine Meters Models 3" Through 16" MV Series Service

Smith Meter TM Turbine Meters Models 3 Through 16 MV Series Service Issue/Rev. 0.1 (1/98) Smith Meter TM Turbine Meters Models 3" Through 16" MV Series Service Bulletin MN02010 Contents Section 1 General Information... Page 2 Return Procedures... Page 2 Section 2 Service...

More information

Issue/Rev. 0.3 (2/04) Bulletin P

Issue/Rev. 0.3 (2/04) Bulletin P Form No. P0906.03 E-Type Transmitter Parts List Issue/Rev. 0.3 (2/04) Bulletin P0906.03 (Previous Design) Switch and Network Assembly The Switch and Network Assembly is no longer available. To replace

More information

Non Ferrous Aircraft Fueling Meters

Non Ferrous Aircraft Fueling Meters Issue/Rev. 0.3 (6/02) Smith Meter TM PD Rotary Vane Meter Non Ferrous ircraft Fueling Meters Specifications Bulletin SS01009 The Smith Meter TM ircraft Refueling Meters are non ferrous, single case, rotary

More information

Smith Meter PD Meters Meter, PD Series, M16-S3, S5, S6 (1993-Present) Parts List

Smith Meter PD Meters Meter, PD Series, M16-S3, S5, S6 (1993-Present) Parts List Issue/Rev. 0.0 (1/14) Smith Meter PD Meters Meter, PD Series, M16-S3, S5, S6 (1993-Present) Parts List Bulletin PO01023 *For meters which began shipping in 1993 to current. For meters shipped prior to

More information

Smith PD Rotary Vane Meters F4 PRIME Cover Field Retrofit Procedure Service Bulletin

Smith PD Rotary Vane Meters F4 PRIME Cover Field Retrofit Procedure Service Bulletin Smith PD Rotary Vane Meters F4 PRIME Cover Field Retrofit Procedure Service Bulletin Issue/Rev. 0.1 (11/02) Bulletin SV01009 Tools and Parts Required P/N 554583-001, Parts kit for F4 PRIME retrofit P/N

More information

Model G6-S3. Repeatability ±0.02%

Model G6-S3. Repeatability ±0.02% Issue/Rev. 0.6 (2/07) Smith Meter TM PD Rotary Vane Meter 6" Steel Model G6 Specifications Bulletin SS01014 The Smith Meter TM Model G6 Meter is a 6", double-case, straight-through (S3 through S8) or angle-type

More information

Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7

Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7 Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7 Parts List Bulletin PO01018 Issue/Rev 0.1 (7/13) S1, S3, S5 S6, S7 Item Description Qty. K12-S1 K12-S5 K12-S7 Page 2 SS01018 Issue/Rev.

More information

Model DE-3 Air Release Heads Parts List

Model DE-3 Air Release Heads Parts List Issue/Rev. 0.0 (1/14) Smith Meter Air Eliminator Model DE-3 Air Release Heads Parts List Bulletin MN03021 Contents Section 1 Introduction... Page 2 Principle of Operation... Page 2 Section 2 Installation...

More information

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology VALVE CONTROLLERS Controllers for Dust Extraction 2010 Technology / 2011 Valve controllers for all cases HESCH has the skills and technology to tackle any control task for dedusting of filter and dust

More information

MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1.

MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1. SPECIFICATIONS MEASUREMENT SOLUTIONS MV Series Bulletin SS02016 Issue/Rev. 1.7 (9/14) We put you first. And keep you ahead. SMITH METER TURBINE METERS The Smith Meter MV Series Turbine Meter is intended

More information

Orifice Fittings and Meter Tubes

Orifice Fittings and Meter Tubes Smith Meter TM Issue/Rev. 0.0 (9/06) Orifice Fittings and Meter Tubes Technical Paper Bulletin TPOG001 Introduction Throughout the oil and gas industry, there stems the need for accurate, economical measurement

More information

EPAS Desktop Pro Software User Manual

EPAS Desktop Pro Software User Manual Software User Manual Issue 1.10 Contents 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started 6 2.1

More information

Smith Meter TM Turbine Meters Models 4" Through 24" Sentry TM Series. Service. Contents

Smith Meter TM Turbine Meters Models 4 Through 24 Sentry TM Series. Service. Contents Smith Meter TM Turbine Meters Models 4" Through 24" Sentry TM Series Service Issue/Rev. 0.3 (8/02) Bulletin MN02004 Contents Section 1 General Information... Page 2 Return Procedures... Page 2 Section

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter

CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter -E DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter Contents 1 General Remarks... 1-1 1.1 About This Manual... 1-1 1.2 How to Use This Manual... 1-1 2 Approval... 2-1 2.1 Explosion

More information

LAMBDA SENSOR CONTROLLER

LAMBDA SENSOR CONTROLLER LAMBDA SENSOR CONTROLLER INSTALLATION & PROGRAMMING MANUAL version : V1.77 -V1.79 Manufacturer: AC Spółka Akcyjna. 15-182 Białystok, ul. 27 Lipca 64, Poland tel. +48 85 7438148, fax +48 85 653 8649 www.ac.com.pl,

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16 User Manual CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 1 - LIN072UE - 04/16 Table of Contents 1 Introduction... 3 1.1 Precautions Before Starting... 3 1.2 Troubleshooting... 3 1.3 General Disclaimer...

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH EN Dusty / Dusty Ex Operating Instructions Low-Cost Broken Bag Detection SWR engineering Messtechnik GmbH CONTENTS Page 1. Introduction.............................................................. 3 1.1

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

Fuse state indicator MEg72. User manual

Fuse state indicator MEg72. User manual Fuse state indicator MEg72 User manual MEg Měřící Energetické paráty, a.s. 664 31 Česká 390 Czech Republic Fuse state indicator MEg72 User manual Fuse state indicator MEg72 INTRODUCTION The fuse state

More information

Smith Meter PD Meters 3" Steel Model E3

Smith Meter PD Meters 3 Steel Model E3 Smith Meter PD Meters 3" Steel Model E3 Specifications Bulletin SS01016 Issue/Rev 1.0 (8/13) The Smith Meter Model E3 is a 3", double-case, straight-through (S1 through S7) or angle-type (A1 and A3), rotary

More information

Transmitter, Model UPT

Transmitter, Model UPT Form No. P0907.05 Transmitter, Model UPT Parts List Issue/Rev. 0.5 (5/11) Bulletin P0907.05 Universal Pulse Transmitter 554665-0-1X Single Shaft Design The Most Trusted Name In Measurement Universal Pulse

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection

More information

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 , IECEx EPS 16.0030X Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

Counters, Printers, Preset Counters

Counters, Printers, Preset Counters SPECIFICATIONS Counters, Printers, Preset Counters Bulletin SS01100 Issue/Rev. 0.3 (10/17) Smith Meter PD Meter Accessories High Capacity and Large Numeral Counters Model 600 and 900 Series Non-Reset CountersModel

More information

REVISION HISTORY REVISION HISTORY

REVISION HISTORY REVISION HISTORY FILTER CONTROLLER REVISION HISTORY Filter Flush Controller forms part of the Netafim range of filtration controllers all designed to make filteration more reliable and economical.. Contact any of the Netafim

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

ILED Dorado. User Manual

ILED Dorado. User Manual 10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...

More information

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 , IECEx PTB 14.0049X Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18)

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18) SPECIFICATIONS MV Series Bulletin SS02016 Issue/Rev. 2.0 (2/18) Smith Meter Turbine Meters The Smith Meter MV Series Turbine Meter is intended for the measurement of crude oils and other products having

More information

Declaration of Conformity

Declaration of Conformity Declaration of Conformity We, Manufacturer: Spartanics Ltd. 3605 Edison Place Rolling Meadows, Illinois 60008 Phone: 847-394-5700 Fax: 847-394-0409 USA ENGLISH declare under our sole responsibility that

More information

ZE motor-protective relay Overload monitoring of EEx e motors

ZE motor-protective relay Overload monitoring of EEx e motors Building Automation Industrial Automation Systems Hardware and Engineering ZE motor-protective relay Overload monitoring of EEx e motors 0/0 AWB300-5GB A Think future. Switch to green. All brand and product

More information

Centrifugal fan with highly efficient EC drive motor

Centrifugal fan with highly efficient EC drive motor Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany

More information

ThunderION. Static Neutralising System. GB User's Manual 2

ThunderION. Static Neutralising System. GB User's Manual 2 ThunderION SIMCO (Nederland) B.V. Postbus 71 NL-7240 AB Lochem Telefoon +31-(0)573-288333 Telefax +31-(0)573-257319 E-mail general@simco-ion.nl Internet http://www.simco-ion.nl Traderegister Apeldoorn

More information

DC Master 24/ A

DC Master 24/ A USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015

More information

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Data Sheet DS/NGB-EN Rev. B Multi barriers Measurement made easy Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Change from two to one column Multi barriers Change from one to two columns

More information

Issue 2.0 December EPAS Midi User Manual EPAS35

Issue 2.0 December EPAS Midi User Manual EPAS35 Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started

More information

707Ex. Users Manual. ma Calibrator

707Ex. Users Manual. ma Calibrator 707Ex ma Calibrator Users Manual March 2003 Rev 2 3/03(English) 2003 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. Table of Contents

More information

Flow Conditioners. We put you first. And keep you ahead. FEATURES OPTIONS. Bulletin SS02007 Issue/Rev. 0.9 (10/14)

Flow Conditioners. We put you first. And keep you ahead. FEATURES OPTIONS. Bulletin SS02007 Issue/Rev. 0.9 (10/14) SPECIFICATIONS MEASUREMENT SOLUTIONS Flow Conditioners Bulletin SS02007 Issue/Rev. 0.9 (10/14) We put you first. And keep you ahead. Smith Meter TURBINE METERS Smith Meter Flow Conditioners optimize turbine

More information

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals ABB MEASUREMENT & ANALYTICS DATA SHEET TEIP11 I/P signal converter for standard signals 2 TEIP11 I/P SIGNAL CONVERTER FOR STANDARD SIGNALS DS/TEIP11-EN REV. D Flow in air pressure Proven and reliable concept

More information

Installation Instructions & Users Manual

Installation Instructions & Users Manual Installation Instructions & Users Manual UTILITY/ BUILDING INPUT 120 VAC ( OPTION) 15-20A N L CONTROL BOARD G SECURITY LIGHTING POWER SUPPLY (OPTION) CHARGER- POWER SUPPLY ASSBY XFMR (OPTION) CBM MODEL

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K Temperature Measuring insert For thermocouple with flameproof enclosure (TC1-L) Model TC1-K WIKA data sheet TE 65.11 for further approvals see page 2 Applications Replacement measuring insert for servicing

More information

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical

More information

BRAKE TESTER DECELEROMETER

BRAKE TESTER DECELEROMETER OC3010_GBM_21009 BRAKE TESTER DECELEROMETER OWNER S MANUAL Version 8.++ ORBIT CONTROLS AG Zürcherstrasse 137 CH-8952 Schlieren/ZH Tel: + 41 44 730 2753 Fax: + 41 44 730 2783 info@orbitcontrols.ch www.orbitcontrols.ch

More information

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT

CATALOGUE Opto-Electronics STRACK LIFT AUTOMATION ILGT CATALOGUE Opto-Electronics 2018.1 ILGT 5.4 Opto-Electronics 2018.1 ILGT ILGT ILGT Opto-Electronics 2018.1 5.4 Safety light grid for power operated gates, also secure directly the wing path of vertically

More information

Guide for installers. METTLER TOLEDO MultiRange Explosionsproof weighing system with the ID3sTx weighing terminal.

Guide for installers. METTLER TOLEDO MultiRange Explosionsproof weighing system with the ID3sTx weighing terminal. Guide for installers METTLER TOLEDO MultiRange Explosionsproof weighing system with the ID3sTx weighing terminal Hazardous zone ID3sTx weighing terminal LWL Safe zone Dual Channel Fiber Optic Converter

More information

103 Differential Pressure Switch

103 Differential Pressure Switch These instructions provide information for installation, electrical connection, process connection and calibration of 103 Differential Pressure Switches. Process pressure is sensed by a diaphragm and piston

More information

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX ATEX Type Certification marking for type L1X-EX, T1X-EX, T2X-EX Type of protection "d" explosion-proof enclosure Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

More information

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS MAKING MODERN LIVING POSSIBLE UniLynx Indoor Installation Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 Installation Sequence 2 Important

More information

ExBin-P Pressure switches 5 Pa Pa

ExBin-P Pressure switches 5 Pa Pa ExBin-P Pressure switches 5 Pa... 5.000 Pa Electrical, explosion-proof binary pressure / differential pressure switches 5 Pa...100 Pa with adjustable switch activation delay 24 VAC/DC supply voltage, potential

More information

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. LP-Series SE Replacement Installation Manual

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. LP-Series SE Replacement Installation Manual Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology LP-Series SE Replacement 1. Contact information United States General Tel: +1-919-677-0100 Fax: +1-919-677-2343 E-mail:

More information

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007) Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

HP DesignJet 430 HP DesignJet 450C HP DesignJet 455CA Printers. Service Manual

HP DesignJet 430 HP DesignJet 450C HP DesignJet 455CA Printers. Service Manual HP DesignJet 430 HP DesignJet 450C HP DesignJet 455CA Printers Service Manual For HP Internal Use Only Copyright Hewlett- Packard Company 1997 This document contains proprietary information that is protected

More information

BMS24. Thanks for your purchasing the BMS24 for your vehicle.

BMS24. Thanks for your purchasing the BMS24 for your vehicle. BMS24 for 2S-24S LiPo & LiFe Low power consumption High accuracy 2.8 TFT LCD display Programmable Thanks for your purchasing the BMS24 for your vehicle. Read the ENTIRE instruction manual to become familiar

More information

POWER SUPPLY aps-412_en 06/16

POWER SUPPLY aps-412_en 06/16 APS-412 POWER SUPPLY aps-412_en 06/16 The APS-412 switching power supply has been designed for use with 12 V DC electrical devices. It comes with a dedicated connector allowing for integration with Satel's

More information

BMS16. Thanks for your purchasing the BMS16 for your vehicle.

BMS16. Thanks for your purchasing the BMS16 for your vehicle. BMS16 BMS for 2S-16S LiPo & LiFe Low power consumption High accuracy 2.8 TFT LCD display Programmable Thanks for your purchasing the BMS16 for your vehicle. Read the ENTIRE instruction manual to become

More information

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0) Data Sheet SCHISCHEK EXCOS-P Pressure sensor 20 Pa... 7.500 Pa Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com ExCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical, explosion-proof

More information

Technical Documentation

Technical Documentation Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

c-go 24V/6A 24V/8A 24V/12A

c-go 24V/6A 24V/8A 24V/12A c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

MT50 & MT150 Electrical Multi-turn Valve Actuators

MT50 & MT150 Electrical Multi-turn Valve Actuators User Manual MT50 & MT150 Electrical Multi-turn Valve Actuators Rev 4.2 EQS ID 1374 Page 1 of 25 Table of Contents 1. Introduction... 3 2. Specifications and manual operation... 4 2.1 Technical data...

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Product Data Sheet. Damper Interface. Features

Product Data Sheet. Damper Interface. Features Damper Interface Product Data Sheet Features Damper Motor drive and limit switch monitoring integrated into a single unit Dual limit switch inputs for confirmation of damper-fully-open and damperfully-closed

More information

102 Differential Pressure Switch

102 Differential Pressure Switch Knurled cap over set point adjustment High side process connection 1/4 NPT(F) [1/2 NPT(F) optional] onal] Hermetically sealed switching element capsule with 18 AWG wire leads, 18 (45.7 cm) in length 102

More information

Micro Valve. Quick, Sure Response with Design Adaptability. Features and Benefits. Applications. Dependable Performance SPECIFICATIONS / PARTS LIST

Micro Valve. Quick, Sure Response with Design Adaptability. Features and Benefits. Applications. Dependable Performance SPECIFICATIONS / PARTS LIST SPECIFICATIONS / PARTS LIST Micro Valve Bulletin SSIN064 Issue/Rev. 0.0 (2/18) Since its introduction in 1956, Micro Valve has provided successful service through thousands of applications. This makes

More information

Elmdene International Ltd

Elmdene International Ltd 1 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44(0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk 13.8Vdc Switch Mode Power Supply GEN3-08-y

More information

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT-161609 Read before commencement of all work! This ignition unit must be mounted in accordance with the applicable

More information

Electrical operating instructions

Electrical operating instructions en Electrical operating instructions Door control panel TS 958 Software 1.0 - (Design and functions subject to change) 51171324 - c 03.2007 OPERATING INSTRUCTIONS Page SAFETY DIRECTIONS...4 INSTALLATION

More information

Meter, PD Series, K12-S1, S3, S5, S6 and S7

Meter, PD Series, K12-S1, S3, S5, S6 and S7 PARTS LIST Meter, PD Series, K12-S1, S3, S5, S6 and S7 Bulletin PO01018 Issue/Rev. 0.4 (3/18) S1, S3, S5 S6, S7 Item Description Qty. K12-S1 K12-S5 K12-S7 2 Bulletin PO01018 Issue/Rev. 0.4 (3/18) Item

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:

More information

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10 our name is our principle UV- TECHNOLOGY Technical Documentation ELC N6 / ELC N8 / ELC N10 GB eta plus electronic gmbh Lauterstraße 29, D-72622 Nürtingen, Telefon +49 (0) 70 22-60 02-80, Fax +49 (0) 70

More information

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet. Description Marking The ANTARES ExtSet makes it possible to distribute the Remote I/O ANTARES modules of an explosion-protected Remote I/O system ANTARES among a maximum of 4 metal mounting rails. For

More information

X117E. X117E Contact-Less Valve Position Transmitter INSTALLATION / OPERATION / MAINTENANCE MODEL. X117E Contact-Less Valve Position Transmitter

X117E. X117E Contact-Less Valve Position Transmitter INSTALLATION / OPERATION / MAINTENANCE MODEL. X117E Contact-Less Valve Position Transmitter X117E Contact-Less Valve Position Transmitter Thank you for purchasing a Cla-Val Model X117E Contact-less Valve Position Transmitter. With proper maintenance, the X117E will perform indefinitely and provide

More information

GEMÜ 539 esydrive Motorized globe valve

GEMÜ 539 esydrive Motorized globe valve esydrive Motorized globe valve Features Linear or modified equal-percentage control characteristics High flow rates Force and speed are variably adjustable Extensive diagnostic facilities Operable via

More information

Operating Instructions (Translation)

Operating Instructions (Translation) Product Description Definition The ANTARES RCU consists of the ANTARES Head Module and the ANTARES Connection Module. The ANTARES Head Module contains a CPU, communication interface and power pack. In

More information

Digital Room Thermostats with Touch Screen LCD

Digital Room Thermostats with Touch Screen LCD TC40 Touch Series Digital Room Thermostats with Touch Screen LCD Revision Date February 22, 2013 Features Wall-mount Display Control to match any decor Extra large easy-to-read Liquid Crystal Display (LCD),

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Exi Solenoid Driver, With Intrinsically Safe Output, LoopPowered, TwoChannel INTERFACE Data Sheet 0289_00_en PHOENIX CONTACT 0/2008 Description The PIEXME2SD/24/65C is a twochannel solenoid driver. It

More information