1 Empa Überlandstrasse 129 CH-8600 Dübendorf Tel. +41 (0) Fax +41 (0) Materials Science & Technology Lista AG Betriebs- und Lagereinrichtungen CH-8586 Erlen Test Report No Test Assignment: Check of Standard Conformity of Slide Tests Test Object: Client Ref.: Summary Fulterer GesmbH slides (FR and FR B) according to Lista AG specifications (Customer) Mr. A. Amacker Order dated of: September 22/2008 Test Object received: - Test performed: September November 2008 Number of Pages: 33 Dispatch: Dispatch: Archive: - None 3 Copies to Customer The company Fulterer GesmbH (A-6890 Lustenau) manufactures drawer slides and tests them in its own laboratory according to DIN and RAL-RG 614/8 standards. The goal of this order was to be on hand to inspect the testing equipment and test procedures in the testing of two types of slides (load capacity of 200 kg and 75 kg), and to check whether the tests conform to the standards mentioned. The following determination can be made: The selected tests were carried out correctly using suitable testing equipment. The slides tested have passed the tests performed on them. The testing method used is not within the scope of the accreditation. However, all testing activities are subject to the Empa quality management system in any case. Dübendorf, 12/03/2008 Project manager: Dr. G. Piskoty Swiss Federal Laboratories for Materials Testing and Research Lab. Mechanical Systems Engineering Head of Laboratory representative: Dr. G. Kovacs Remark: The test results are valid solely for the object tested. The use of the test reports for the purpose of publicity, the mere reference to them or publication of excerpts require the approval of the Empa (see Information Note). Test reports and supporting documents are retained for 10 years.

2 Empa, Laboratory: 117 Mechanical Systems Engineering Page 2 von 33 TABLE OF CONTENTS 1 Goal TIMING AND ORGANIZATIONAL STRUCTURE CHECK OF LOADS ON THE SLIDES Weight Check of Load-Sacks Drawer Weight Check INVESTIGATIONS Durability tests according to RAL-RG 614/8, Section Test equipment Test of slide FR (nominal load 200 kg) Test of slide FR B (nominal load 75 kg) Test of the Deflection of the Front of the Drawer during the Durability Test according to DIN 68858, Section Test method Test of slide FR (nominal load 200 kg) Test of slide FR B (nominal load 75 kg) Test of Opening Force according to DIN 68858, Section Test method Test of slide FR (nominal load 200 kg) Test of slide FR B (nominal load 75 kg) Test of Closing Force according to DIN 68858, Section Test method Test of slide FR (nominal load 200 kg) Test of slide FR B (nominal load 75 kg) Vertical Load Test according to DIN 68858, Section Test method Test of slide FR (load capacity 200 kg) Test of slide FR B (load capacity 75 kg) Horizontal Load Test according to DIN 68858, Section Test method Test of slide FR (load capacity 200 kg) Test of slide FR B (load capacity 75 kg) Test of Pull-Out Retention according to RAL-RG 614/8, Section Test setup Test of slide FR (load capacity 200 kg) Test of slide FR B (load capacity 75 kg)...23

3 Empa, Laboratory: 117 Mechanical Systems Engineering Page 3 von 33 5 Summary List of sources Test protocols pf the Fulterer GesmbH Test protocol D Test protocol D Test protocol A Test protocol A...32

4 Empa, Laboratory: 117 Mechanical Systems Engineering Page 4 von 33 LIST OF FIGURES Figure 1: Weight measurement of a randomly selected blue steel bead sack on a Mettler TE 30 J scale (property of Empa, Log. No )... 6 Figure 2 Measurement of the weight of drawer A on a Mettler TE 30 J scale (Empa Log. No )... 7 Figure 3: Drawer tester at testing laboratory of Fulterer GesmbH... 8 Figure 4: Screen display of controlling computer of the drawer tester... 8 Figure 5: Measurement of the height and drop of the front of the drawer using a height gauge (recorded after 300 cycles of the durability test on slide FR ) Figure 6: Measurement of opening force for a loaded drawer (recorded on Sep. 22, 2008 after about 300 cycles of the durability test of slide FR ) Figure 7: Check of spring scale using an attached steel cylinder of kg (recorded on Sep. 26, 2008) Figure 8: Weight measurement of steel cylinder including connector used to check the spring scale (scale: Mettler TE 30 J, Empa Log. No , Display: kg) Figure 9: Set-up for the measurement of closing force for a loaded drawer (pictures obtained from the Fulterer GesmbH) Figure 10: Measurement of closing force for a loaded drawer (pictures obtained from the Fulterer GesmbH) Figure 11: Measurement of closing force for a loaded drawer (pictures obtained from the Fulterer GesmbH) Figure 12: Vertical load of the drawer in test of slide FR (load capacity 200 kg) Figure 13: Weight measurement of steel cylinder on Mettler TE 30 J scale (Empa Log. No ) Figure 14: Weight measurement of steel cylinder on Mettler TE 30 J scale (Empa Log. No ) Figure 15: Horizontal load of the drawer in test of slide FR (load capacity 200 kg), recorded on Sep. 22, Figure 16: Photo during the impact test of slide FR on Sep. 22, 2008 (drawer loaded with 9 sacks, each with a nominal mass of 5 kg, total load on slides: approx. 53 kg) Figure 17: Check of inclination during impact tests using a digital inclinometer (Empa LogNo , resolution 0.1º) Figure 18: Slight impact traces at stop of slide FR after three impact test series with 10 impacts per series Figure 19: Recorded during the impact test of slide FR B (loading of the drawer with 9 sacks, each with a nominal mass of 5 kg; total load on the slides: approx. 53 kg) Figure 20: Slight impact traces at stop of slide FR B after two impact test series with 10 impacts per series Archiving of Figures: The figures of this document are clearly defined by the project number and figure number.

5 Empa, Laboratory: 117 Mechanical Systems Engineering Page 5 von 33 1 GOAL The company Fulterer GesmbH (A-6890 Lustenau) manufactures drawer slides that are installed in drawer cabinets made by the client and by others (Lista AG). The drawer slides are tested by Fulterer in its own laboratory according to DIN and RAL-RG 614/8 standards. The goal of this order was to be on hand to inspect the testing equipment and test procedures in the testing of two types of slides (load capacity of 200 kg and 75 kg), and to check whether the tests conform to the standards mentioned. The tests to be performed were agreed upon between Lista AG and Fulterer GesmbH. Remark: This report bases on the same tests reported in the Empa Test Report No , completed with documentation of additional tests. 2 TIMING AND ORGANIZATIONAL STRUCTURE The tests took place from September 2008 through November The Empa project manager was present - in consultation with the client and with Fulterer GesmbH -on the afternoon of Sep. 22, 2008 (initial stage of the tests) and the morning of Sep. 26, 2008 (conclusion of the tests) on site in Lustenau. The test specimens (tested slides) and the equipment and aids (such as sacks with which to load the drawers) belong to Fulterer GesmbH and were selected by the company. Empa project managers only brought along measurement devices that were used for the purposes of checking (scale, declinometer and gauge). 3 CHECK OF LOADS ON THE SLIDES 3.1 Weight Check of Load-Sacks In DIN Standard 68858, Section 2 specifies the use of sacks filled with glass beads as a load on the drawers; each sack should weigh 1 kg. For impact testing, a single loosely filled sack that is approximately e- qual in size to the size of the drawer is prescribed. In the tests carried out (Chap. 4), the drawers were loaded with sacks that had been filled with steel beads. The sacks had different nominal weights according to color: green: m g = 2.5kg red: m r = 5kg blue: m b = 10 kg The effective mass of the sacks were checked on Sep. 26, 2008; 3 sacks were selected at random (Figure 1). It has been shown that all sacks that were checked are slightly heavier than their nominal weight (Table 1). This is a deviation in a conservative direction.

6 Empa, Laboratory: 117 Mechanical Systems Engineering Page 6 von 33 Figure 1: Weight measurement of a randomly selected blue steel bead sack on a Mettler TE 30 J scale (property of Empa, Log. No ) Sack color Nominal weight [kg] Measured value [kg] Nr. 1 Nr. 2 Nr. 3 Mean value [kg] Deviation from nominal weight [%] blue red green Table 1: Measured weight of randomly selected sacks

7 Empa, Laboratory: 117 Mechanical Systems Engineering Page 7 von Drawer Weight Check In loading the slides, the dead weight of the drawers was also included at 5 kg. The effective mass of the drawers used in the tests was measured on Sep. 26, 2008 (Figure 2). What was seen was that both drawers had a weight of ms = 7.18 kg Thus, the effective weight of the slides was greater than assumed due to the dead weight of the drawer. This is a deviation in a conservative direction. Figure 2 Measurement of the weight of drawer A on a Mettler TE 30 J scale (Empa Log. No )

8 Empa, Laboratory: 117 Mechanical Systems Engineering Page 8 von 33 4 INVESTIGATIONS Below, the individual investigations are described, grouped according to type of investigation. The standard requirements are not described in detail. They can be found directly from the standards mentioned. 4.1 Durability tests according to RAL-RG 614/8, Section Test equipment The tests were carried out at the computer-controlled testing facility of Fulterer GesmbH (Figure 3 and Figure 4). A check of the facility showed that it is suitable for correctly executing the durability safety test tests according to RAL-RG 614/8. Figure 3: Drawer tester at testing laboratory of Fulterer GesmbH a) Overview mode b) Overview mode Figure 4: Screen display of controlling computer of the drawer tester

9 Empa, Laboratory: 117 Mechanical Systems Engineering Page 9 von Test of slide FR (nominal load 200 kg) When the Empa project manager arrived on Sep. 22, 2008, the test was already under way. According to the screen display of the controlling computer, about 300 cycles were already completed. The test velocity setting for closing and opening was less than the value of 0.25 m/s determined in DIN Standard under Section This value was corrected by Mr. Raid (Fulterer GesmbH) to match the standard specification. Although the influence of the velocity deviation during the first 300 cycles had little to no nominal effect on the test results, the controls of the test equipment were adjusted by Mr. Raid and the test was run for another 5000 cycles (full test scope according to RAL-RG 614/8, Section ). The Empa project manager was present at the start of the further 5000 cycles. The majority of the test proceeded automatically, under the supervision of Mr. Raid. After the completion of the total of 5300 cycles (5000 cycles of which were run at the correct velocity), the slides were checked by Mr. Raid. The test log issued by Fulterer GesmbH can be found in Chap According to this log, the slides passed the test Test of slide FR B (nominal load 75 kg) The test proceeded fully automatically under the supervision of employees of Fulterer GesmbH. The test log issued by Fulterer GesmbH can be found in Chap According to this log, the slides passed the test.

10 Empa, Laboratory: 117 Mechanical Systems Engineering Page 10 von Test of the Deflection of the Front of the Drawer during the Durability Test according to DIN 68858, Section Test method On Sep. 22, 2008, the drawer front deflection measurement procedure was demonstrated by Mr. Raid for the Empa project manager. The measurement was done using a Height gauge of Fulterer GesmbH (registered from the Quality Assurance department of Fulterer GesmbH) in proper fashion (Figure 1). Height gauge Figure 5: Measurement of the height and drop of the front of the drawer using a height gauge (recorded after 300 cycles of the durability test on slide FR ) Test of slide FR (nominal load 200 kg) According to information from Mr. Corona (Fulterer GesmbH), all logged height measurements were done in the same fashion as the measurement demonstrated by Mr. Raid on Sep. 22, 2008 (Fig 5). The measured values can be found in Chap According to this, the drop was 21.2 mm. This measured value is smaller than the allowable maximum value, which is defined in the standard as 4% of the slide path (0.04 x 630 mm = 25.2 mm). Thus, it can be determined that the slide met the requirements of the standard Test of slide FR B (nominal load 75 kg) According to information from Mr. Corona, all logged height measurements were done in the same fashion as the measurement demonstrated by Mr. Raid on Sep. 22, (Figure 5). The measured values can be found in Chap According to this, the drop was 15.0 mm. This measured value is smaller than the allowable maximum value, which is defined in the standard as 4% of the slide path (0.04 x 630 mm = 25.2 mm). Thus, it can be determined that the slide met the requirements of the standard.

11 Empa, Laboratory: 117 Mechanical Systems Engineering Page 11 von Test of Opening Force according to DIN 68858, Section Test method On Sep. 22, 2008, the opening force measurement procedure was demonstrated by Mr. Raid for the Empa project manager. The measurement was done using a spring scale of Fulterer GesmbH (obtained from the Quality Assurance department under number QS 01167) in correct fashion (Figure 6). Front of drawer Motion Spring scale Figure 6: Measurement of opening force for a loaded drawer (recorded on Sep. 22, 2008 after about 300 cycles of the durability test of slide FR ) The precision of the spring scale was checked by hanging a steel cylinder with a know weight from it (Figure 7 and Figure 8). This check showed that the precision of the spring scale was sufficient.

12 Empa, Laboratory: 117 Mechanical Systems Engineering Page 12 von 33 Spring scale Display: 21.6+/- 0.1 kg m = kg, see Figure 8 Figure 7: Check of spring scale using an attached steel cylinder of kg (recorded on Sep. 26, 2008) Figure 8: Weight measurement of steel cylinder including connector used to check the spring scale (scale: Mettler TE 30 J, Empa Log. No , Display: kg)

13 Empa, Laboratory: 117 Mechanical Systems Engineering Page 13 von Test of slide FR (nominal load 200 kg) According to information from Mr. Corona all slide force measurements were made in the same fashion as was demonstrated on Sep. 22, The corresponding measured values are listed in Chap According to this, the maximum opening force was 90 ± 10 N. In the standard, the maximum allowable opening force is only indicated for a slide path of up to 500 mm and test load of 100 kg, indicated as 12.5% of the test load. For the existing slide path of 630 mm, according to DIN special agreements will have to be made. Conservatively, one can assume a limit of x 100 kg x 9.81 m/s N. This value is higher than the measured opening force. Consequently, the slide passed the test Test of slide FR B (nominal load 75 kg) According to information from Mr. Corona all slide force measurements were made in the same fashion as was demonstrated on Sep. 22, The corresponding measured values are listed in Chap According to this, the maximum opening force was 50 ± 10 N. In the standard, the maximum allowable opening force is only indicated for a slide path of up to 500 mm and test load of 100 kg, indicated as 12.5% of the test load. For the existing slide path of 630 mm, according to DIN special agreements will have to be made. Conservatively, one can assume a limit of x 75 kg x 9.81 m/s 2 93 N. This value is higher than the measured opening force. Consequently, the slide passed the test.

14 Empa, Laboratory: 117 Mechanical Systems Engineering Page 14 von Test of Closing Force according to DIN 68858, Section Test method The tests were performed by the Fulterer GesmbH, using the same spring scale as for the Opening-tests. Based on the photo documentation of the tests, obtained from Fulterer GesmbH on December 02, 2008, the tests were performed in correct fashion (Figure 9). deflection pulley Testaufbau Bild 2.jpg Spring scale Spring scale Testaufbau Bild 1.jpg a) view before mounting the drawer a) view after mounting the drawer Figure 9: Set-up for the measurement of closing force for a loaded drawer (pictures obtained from the Fulterer GesmbH)

15 Empa, Laboratory: 117 Mechanical Systems Engineering Page 15 von Test of slide FR (nominal load 200 kg) The closing test was performed before and after the long term test (Chapter 4.1) on loaded drawer (200kg). The measured values are listed in Chap According to this, the maximum closing force amounted to: 220 N ± 10 N before the long term test (Figure 10/a) 240 N ± 10 N after the long term test (Figure 10/b) In the standard, the maximum allowable closing force is only indicated for a slide path of up to 500 mm and test load of 100 kg, indicated as 12.5% of the test load. For the existing slide path of 630 mm, according to DIN special agreements will have to be made. One can assume a limit of x 200 kg x 9.81 m/s N. This value is higher than the measured closing forces. Consequently, the slide passed the test. FR7180 im Neuzustand.jpg FR7180 nach Dauertest D.jpg a) before the long term test b) before and after the long term test Figure 10: Measurement of closing force for a loaded drawer (pictures obtained from the Fulterer GesmbH)

16 Empa, Laboratory: 117 Mechanical Systems Engineering Page 16 von Test of slide FR B (nominal load 75 kg) The closing test was performed before and after the long term test (Chapter 4.1) on loaded drawer (75 kg). The measured values are listed in Chap According to this, the maximum closing force amounted to: 60 N ± 10 N before the long term test (Figure 11/a) 70 N ± 10 N after the long term test (Figure 11/b) In the standard, the maximum allowable closing force is only indicated for a slide path of up to 500 mm and test load of 100 kg, indicated as 12.5% of the test load. For the existing slide path of 630 mm, according to DIN special agreements will have to be made. One can assume a limit of x 75 kg x 9.81 m/s N. This value is higher than the measured closing forces. Consequently, the slide passed the test. FR7075 im Neuzustand.jpg FR7075 nach Dauertest D.jpg a) before the long term test b) before and after the long term test Figure 11: Measurement of closing force for a loaded drawer (pictures obtained from the Fulterer GesmbH)

17 Empa, Laboratory: 117 Mechanical Systems Engineering Page 17 von Vertical Load Test according to DIN 68858, Section Test method According to standard specifications, the forward edge of the fully loaded drawer must be subjected to a force of 200 N. In the tests, the load was produced using a weight of a steel cylinder (Figure 12). The mass of the steel cylinder was kg (Figure 13). This put the effective load of the drawer at about 6% higher than the standard value (deviation in the conservative direction). The length of the slide was set using a tape measure. The correct position of the steel weight on the edge of the drawer was marked with a felt marker. The load duration of 5 seconds each and the pause duration of 15 seconds each were controlled using the second hand of a wristwatch. F 210 N 50 mm Figure 12: Vertical load of the drawer in test of slide FR (load capacity 200 kg)

18 Empa, Laboratory: 117 Mechanical Systems Engineering Page 18 von 33 Figure 13: Weight measurement of steel cylinder on Mettler TE 30 J scale (Empa Log. No ) Test of slide FR (load capacity 200 kg) The test was carried out on Sep. 22, 2008 prior to the restart of the durability test after the first 300 cycles in the presence of the Empa project manager (Figure 12) and on Sep. 23, 2008 following the durability test. After the tests were completed, no damages were found on the slides, and they were fully functional. Thus, the they passed the test. The corresponding test log can be found in Chap Test of slide FR B (load capacity 75 kg) The test was carried out on Sep. 23, 2008 prior to the start of the durability test and on Sep. 24, 2008 following the durability test. According to information from Mr. Corona, the tests were carried out the same way as for slide type FR B. After the tests, no damages were found on the slides and they were fully functional. Thus, the they passed the test. The corresponding test log can be found in Chap. 7.2.

19 Empa, Laboratory: 117 Mechanical Systems Engineering Page 19 von Horizontal Load Test according to DIN 68858, Section Test method According to standard specifications, the test must be done with a force of 75 N. In the tests, the load was produced using a weight of a steel cylinder. The mass of the steel cylinder was 8.84 kg (Figure 14). Figure 14: Weight measurement of steel cylinder on Mettler TE 30 J scale (Empa Log. No ) The steel cylinder was suspended from a thin, flexible steel cord and connected to the front of the drawer through a frictionless rotating guide pulley (Figure 15). The load duration of 5 seconds each and the pause duration of 15 seconds each were controlled using the second hand of a wristwatch. The lateral shift of the front of the drawer was tracked visually. hook for force application Guide pulley F 88 N Cord Steel cylinder m = 8.84 kg Figure 15: Horizontal load of the drawer in test of slide FR (load capacity 200 kg), recorded on Sep. 22, 2008

20 Empa, Laboratory: 117 Mechanical Systems Engineering Page 20 von Test of slide FR (load capacity 200 kg) The test was carried out on Sep. 22, 2008 prior to the restart of the durability test after the first 300 cycles in the presence of the Empa project manager (Figure 12) and on Sep. 23, 2008 following the durability test. After the test, the slides exhibited no damages and were fully functional. The lateral shift of the front of the drawer was negligible. Thus, the slides passed the test. The corresponding test log can be found in Chap Test of slide FR B (load capacity 75 kg) The test was carried out on Sep. 23, 2008 prior to the start of the durability test and on Sep. 24, 2008 following the durability test. According to information from Mr. Corona, the tests were carried out in the same way as for slide type FR B. After the tests, the slides exhibited no damages and were fully functional. The lateral shift of the front of the drawer was negligible. Thus, the slides passed the test. The corresponding test log can be found in Chap. 7.2.

21 Empa, Laboratory: 117 Mechanical Systems Engineering Page 21 von Test of Pull-Out Retention according to RAL-RG 614/8, Section Test setup The test setup is shown in Figure 16. Cabinet, fixed in the tilted position Figure 16: Photo during the impact test of slide FR on Sep. 22, 2008 (drawer loaded with 9 sacks, each with a nominal mass of 5 kg, total load on slides: approx. 53 kg) According to document RAL-RG 614/8, the inclination of the slides must be 10% for the stop tests. The effective tilt of the cabinet and the tilt of the installed slides was checked on Sep. 26, 2008 using a digital inclinometer (Figure 17). Accordingly, the tilt of the slides in the first two tests of slide FR was: n a = TAN (5.7 ) = 9.98% The subsequent tests were done at an increased incline of: n b = TAN (7.2 ) = 12.6%

22 Empa, Laboratory: 117 Mechanical Systems Engineering Page 22 von 33 Inclinometer a) Measurement of cabinet tilt b) Measurement of slide tilt Figure 17: Check of inclination during impact tests using a digital inclinometer (Empa LogNo , resolution 0.1º) Test of slide FR (load capacity 200 kg) On Sep. 22, 2008, three measurement series were carried out in the presence of the Empa project manager with 10 impacts per series at the following slide inclinations (Figure 14): Inclination for Measurement Series No. 1: n = 9.98% Inclination for Measurement Series No. 2: n = 9.98% Inclination for Measurement Series No. 3: n = 12.6% After the tests, the impacts had no perceptible damaging effect (Figure 18) and the slides were fully functional. Thus, the slides passed the test. The corresponding test log can be found in Chap Note: The tilt angles listed in the test log are based on the measurement values of Sep. 22, 2008, which were not determined using the calibrated inclinometer. Figure 18: Slight impact traces at stop of slide FR after three impact test series with 10 impacts per series

23 Empa, Laboratory: 117 Mechanical Systems Engineering Page 23 von Test of slide FR B (load capacity 75 kg) On Sep. 26, 2008, two measurement series were carried out in the presence of the Empa project manager with 10 impacts each at a slide tilt of 12.6% (Figure 19). Thereafter, the stops exhibited no perceptible damaging effect (Figure 20) and the slides were fully functional. Thus, the slides passed the test. The corresponding test log can be found in Chap Figure 19: Recorded during the impact test of slide FR B (loading of the drawer with 9 sacks, each with a nominal mass of 5 kg; total load on the slides: approx. 53 kg) Figure 20: Slight impact traces at stop of slide FR B after two impact test series with 10 impacts per series

24 Empa, Laboratory: 117 Mechanical Systems Engineering Page 24 von 33 5 SUMMARY The two inspections at Fulterer GesmbH left an extremely positive impression. The attending associates of the company, Mr. Raid and Mr. Corona carried out their work professionally. The test equipment used met all essential points of the applicable standard requirements. Deviations were either minor (such as steel beads instead of glass beads as load) or were on the conservative side (such as the effective weight of the filled sacks being greater than their nominal weight). The tests carried out in the presence of the Empa project manager proceeded in conformance with the standard. The test logs issued by Fulterer GesmbH (Chap. 7) were only checked by the Empa project manager with regard to those points that were addressed while he was present (see Chap. 4). The push-out tests were carried out by the Fulterer GesmbH. Based on the obtained documentation of those tests no indication for any irregularity could be detected. In general, all the log entries were estimated to be absolutely reliable. Based on the log entries, the results are summarised in Table 2. Test (abbreviation) Norm Punkt FR Auszug FR B Durability test RAL-RG 614/ passed passed Drop DIN passed passed Opening force DIN passed passed Closing force DIN passed passed Vertical load DIN passed passed Horizontal load DIN passed passed Stopping RAL-RG 614/ passed passed Table 2: Summarizes the results with the aid of the test logs 6 LIST OF SOURCES DIN 68858: RAL-RG 614/8: Möbelschlösser und beschläge Auszugführungen, Schubkästen und Auszüge Anforderungen und Prüfungen, Deutsche Norm, Juni 2004 (Furniture locks and fittings slide designs, drawers and slides - requirements and tests German Norm, June 2004) Güte und Prüfbestimmungen für Schubladenschränke aus Stahl, Deutsches Institut für Gütesicherung und Kennzeichnung e.v. (Quality and test specifications for drawer cabinets made of steel, Deutsches Institut für Gütesicherung und Kennzeichnung e.v)

25 Empa, Laboratory: 117 Mechanical Systems Engineering Page 25 von 33 7 TEST PROTOCOLS PF THE FULTERER GESMBH 7.1 Test protocol D

26 Empa, Laboratory: 117 Mechanical Systems Engineering Page 26 von 33

27 Empa, Laboratory: 117 Mechanical Systems Engineering Page 27 von Test protocol D

28 Empa, Laboratory: 117 Mechanical Systems Engineering Page 28 von 33

29 Empa, Laboratory: 117 Mechanical Systems Engineering Page 29 von Test protocol A

30 Empa, Laboratory: 117 Mechanical Systems Engineering Page 30 von 33

31 Empa, Laboratory: 117 Mechanical Systems Engineering Page 31 von 33

32 Empa, Laboratory: 117 Mechanical Systems Engineering Page 32 von Test protocol A

33 Empa, Laboratory: 117 Mechanical Systems Engineering Page 33 von 33

INFLUENCE OF CROSS FORCES AND BENDING MOMENTS ON REFERENCE TORQUE SENSORS FOR TORQUE WRENCH CALIBRATION

INFLUENCE OF CROSS FORCES AND BENDING MOMENTS ON REFERENCE TORQUE SENSORS FOR TORQUE WRENCH CALIBRATION XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal INFLUENCE OF CROSS FORCES AND BENDING MOMENTS ON REFERENCE TORQUE SENSORS FOR TORQUE WRENCH CALIBRATION

More information

Full extension concealed slide with soft closing and self-closing

Full extension concealed slide with soft closing and self-closing Orderer / Customer: Grass-Hopper (HongKong) Limited 7 th Floor, Allied Kajima Building, 138 Gloucester Road, WanChai, Hong Kong Object / Test specimen: Model no.: Full extension concealed slide with soft

More information

Field test for the comparison of LNG static and dynamic mass measurement methods

Field test for the comparison of LNG static and dynamic mass measurement methods 31 st International North Sea Flow Measurement Workshop 22-25 October 2013 Field test for the comparison of LNG static and dynamic mass measurement methods Tore Mortensen, Justervesenet Henning Kolbjørnsen,

More information

PERFORMANCE OF THE NEW PRIMARY TORQUE STANDARD MACHINE OF INMETRO, BRAZIL

PERFORMANCE OF THE NEW PRIMARY TORQUE STANDARD MACHINE OF INMETRO, BRAZIL PERFORMANCE OF THE NEW PRIMARY TORQUE STANDARD MACHINE OF INMETRO, BRAZIL R. Oliveira 1, L. Cabral 1, U. Kolwinski 2, D. Schwind 2 1 INMETRO National Institute of Metrology, Xerem, Brazil 2 GTM Gassmann

More information

BMW of North America, LLC, Grant of Petition for Decision of. AGENCY: National Highway Traffic Safety Administration (NHTSA),

BMW of North America, LLC, Grant of Petition for Decision of. AGENCY: National Highway Traffic Safety Administration (NHTSA), This document is scheduled to be published in the Federal Register on 11/21/2017 and available online at https://federalregister.gov/d/2017-25168, and on FDsys.gov DEPARTMENT OF TRANSPORTATION National

More information

OPTIMISING CHASSIS ALIGNMENT USING VEHICLE SENSORS

OPTIMISING CHASSIS ALIGNMENT USING VEHICLE SENSORS Link: https://www.springerprofessional.de/en/optimising-chassis-alignment-using-vehicle-sensors/6115514 SPECIAL ASSEMBLY OPTIMISING CHASSIS ALIGNMENT USING VEHICLE SENSORS The commissioning processes at

More information

DÜRR NDT GmbH & CO. KG Höpfigheimer Straße Bietigheim-Bissingen

DÜRR NDT GmbH & CO. KG Höpfigheimer Straße Bietigheim-Bissingen Evaluation of the image quality of a radiographic film emulsion AGFA D7 exposed by X-rays and developed by machine processing (8 min cycle time at 29 C) using Dürr NDT XR D-6 NDT developer and XR F-6 NDT

More information

Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK

Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK -GB-2017-01: Defining the requirements for a GS mark approval Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act about

More information

Worcester Public Schools Student Transportation Contract Proposed Bid Specification Change Summary Sheet

Worcester Public Schools Student Transportation Contract Proposed Bid Specification Change Summary Sheet Worcester Public Schools 2020-2022 Student Transportation Contract Proposed Bid Specification Change Summary Sheet 1 for a five-year period beginning the First Day of Summer School 2015 and ending on the

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11272-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 18.10.2017 to 17.10.2022 Holder of certificate: VDZ

More information

LEAKAGE CLASS ACHIEVED? Wöhler DP 700 LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS. The Measure of Technology GRAPHIC COLOR DISPLAY GRAPHIC

LEAKAGE CLASS ACHIEVED? Wöhler DP 700 LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS. The Measure of Technology GRAPHIC COLOR DISPLAY GRAPHIC LEAKAGE CLASS ACHIEVED? GRAPHIC COLOR DISPLAY COLOR DISPLAY GRAPHIC LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS The Measure of Technology Made in Germany Leakage Tester Just 3 entries to classify

More information

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration)

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration) CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration) Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane Author:

More information

British Gas Comments and Questions on Kelton Engineering Draft SMER

British Gas Comments and Questions on Kelton Engineering Draft SMER British Gas Comments and Questions on Kelton Engineering Draft SMER 13 th September 2013 These comments and questions are associated with the draft SMER produced by Keith Vugler of Kelton Engineering,

More information

Department of Transportation. National Highway Traffic Safety Administration. [Docket No. NHTSA ; Notice 2]

Department of Transportation. National Highway Traffic Safety Administration. [Docket No. NHTSA ; Notice 2] This document is scheduled to be published in the Federal Register on 06/27/2013 and available online at http://federalregister.gov/a/2013-15470, and on FDsys.gov Department of Transportation National

More information

Influence of mounting tube diameter on anemometer output

Influence of mounting tube diameter on anemometer output Influence of mounting tube diameter on anemometer output In cooperation with: Adolf Thies GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Deutsche WindGuard Wind Tunnel Services GmbH Oldenburger Str.

More information

Vibration damping precision couplings

Vibration damping precision couplings Vibration damping precision couplings In light of the advantages of elasticity, strength, resilience, and damping effects, elastomer materials are now being used in most areas of mechanical engineering.

More information

CarePacs. Traceable Balance Testing for Secure Weighing Processes

CarePacs. Traceable Balance Testing for Secure Weighing Processes CarePacs CarePac Weight Sets Ensure valid weighing results Efficient and cost-effective Guaranteed traceability Traceable Balance Testing for Secure Weighing Processes CarePac Weight Sets Ensure Valid

More information

Laboratory Methods for Testing Actuators

Laboratory Methods for Testing Actuators Laboratory Methods for Testing Actuators AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL INC. The International Authority on Air System Components AMCA Publications Authority AMCA International Standard

More information

TROUBLESHOOTING TP. Index

TROUBLESHOOTING TP. Index TROUBLESHOOTING TP Index E1 POWER CUT DETECTED... 2 E2 LOCK ERROR... 3 E3 DRAINAGE FAILURE / WATER IN TUB... 6 E4 MAXIMUM WATER LEVEL REACHED... 6 E5 FAULT WATER INLET... 6 E6 HEATING FAULT... 6 E7 MAXIMUM

More information

Contact person Date Reference Page Hans Eriksson F000838D 1 (3) Wood Technology

Contact person Date Reference Page Hans Eriksson F000838D 1 (3) Wood Technology issued by an Accredited Testing Laboratory Contact person Hans Eriksson 2015-03-26 5F000838D 1 (3) Wood Technology +46 516 54 28 hans.eriksson@sp.se 02 ISO/IEC 17025 Nordic Comfort Products A/S P.O. Box

More information

600 Amp Surge Arrester

600 Amp Surge Arrester R&D Center 497 Schooley s Mountain Road Hackettstown, NJ 07840-3906 Tele: 908-852-1122 Fax: 908-813-2091 TEST REPORT NUMBER: 379-17-12164 DATE: 4-3-2012 REPORT OF TEST ON 600 Amp Surge Arrester Statements

More information

Safety Assessment & Approval System of Shanghai Maglev Demonstration Line and its Practice

Safety Assessment & Approval System of Shanghai Maglev Demonstration Line and its Practice Safety Assessment & Approval System of Shanghai Maglev Demonstration Line and its Practice Wu Tao Shanghai High-Speed Transrapid Project Construction Headquarters, 2520 Long Yang Road, Pudong, 201204,

More information

Sound-absorbing spacer Sorp10

Sound-absorbing spacer Sorp10 Sponsor: Reference number: 7.3 / 27080 This document is only a translated version; not legally attested Max Frank GmbH & Co. KG Mitterweg 1 94339 Leiblfing Federal Institute for Materials Research and

More information

MicroGuard 586 Retrofit Rated Capacity Indicator System. Calibration and Testing for:

MicroGuard 586 Retrofit Rated Capacity Indicator System. Calibration and Testing for: GREER COMPANY Page 1 of 22 MicroGuard 586 Retrofit Rated Capacity Indicator System Machine Model Serial Number Tester Date Calibration and Testing for: GREER COMPANY Page 2 of 22 MicroGuard 586 Retrofit

More information

Optimum design of nozzles tribology systems of a diesel engine fuel injector with high values of rail pressure

Optimum design of nozzles tribology systems of a diesel engine fuel injector with high values of rail pressure Energy and Sustainability VI 379 Optimum design of nozzles tribology systems of a diesel engine fuel injector with high values of rail pressure V. Lazarev 1, G. Lomakin 1, E. Lazarev 1, A. Mylnikov 1 &

More information

Intercomparison Between Trapil, France and NEL, UK Using Oil Flow Turbine Meters

Intercomparison Between Trapil, France and NEL, UK Using Oil Flow Turbine Meters Intercomparison Between Trapil, France and NEL, UK Using Oil Flow Turbine Meters A Report for NMSPU, DTI 151 Buckingham Palace Road London SW1W 9SS Project No: OI/3 (OSDC40300) Report No: 305/99 Date:

More information

Slide Measuring Instrument GMG 200

Slide Measuring Instrument GMG 200 GTE Industrieelektronik GmbH Slide Measuring Instrument GMG 200 entsprechend DIN 51131 und EN 13893 GTE Ind.Elektronik Helmholtz Str. 38-40 D-41747 VIERSEN Tel.: ++49 - (0)2162 3703-0 Fax.:++49 - (0)2162

More information

Laboratory Report. U. S. Department of Justice

Laboratory Report. U. S. Department of Justice U. S. Department of Justice Laboratory Report To: SA CFI Richard Chandler Detroit Field Division 432 N. Saginaw Street Suite 605 Flint, Michigan 48502 Date of Report: Lab Number: 10F0052-1 Reference: 774040110026

More information

Confirmation: / 22 March 2013

Confirmation: / 22 March 2013 Test report: 936/21205333/A of 06 December 2006 Addendum 936/21220762/A of 04 October 2012 Initial certification: 05 March 2013 Date of expiry: 04 March 2018 Publication: BAnz AT 05 March 2013 B10, chapter

More information

Introduction: Supplied to 360 Test Labs... Battery packs as follows:

Introduction: Supplied to 360 Test Labs... Battery packs as follows: 2007 Introduction: 360 Test Labs has been retained to measure the lifetime of four different types of battery packs when connected to a typical LCD Point-Of-Purchase display (e.g., 5.5 with cycling LED

More information

Electric Vehicle Charging Station Incentives PROGRAM HANDBOOK

Electric Vehicle Charging Station Incentives PROGRAM HANDBOOK Electric Vehicle Charging Station Incentives PROGRAM HANDBOOK 1 1 TABLE OF CONTENTS Please ensure you are reading the most recent version of this handbook by visiting the NV Energy website https://www.nvenergy.com/cleanenergy/electric-vehicles

More information

ENERCON GmbH ENERCON E-66. page 1 of 6. Design. Dreekamp 5 Tel.: / Aurich Fax: / Design

ENERCON GmbH ENERCON E-66. page 1 of 6. Design. Dreekamp 5 Tel.: / Aurich Fax: / Design 1 of 6 2 of 6 1 MAIN DATAS 1.1 / 18.70 technical data The E-66 / 18.70 is a wind energy converter with variable speed and active blade tilt via pitch drives. The generator is connected directly to the

More information

This test report describes the test results of the below mentioned paragliding harness. Ozone Gliders Exoceat Medium 7.

This test report describes the test results of the below mentioned paragliding harness. Ozone Gliders Exoceat Medium 7. Test Report This test report describes the test results of the below mentioned paragliding harness. All the tests were carried out by: Air Turquoise SA, official test laboratory of Switzerland. Standards

More information

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition Annex J - Specific requirements for PVT collector Certification 1. Introduction and definition PVT collectors (named hybrid collectors in ISO 9806) generate heat and electric power at the same time. They

More information

Testing of particulate emissions from positive ignition vehicles with direct fuel injection system. Technical Report

Testing of particulate emissions from positive ignition vehicles with direct fuel injection system. Technical Report Testing of particulate emissions from positive ignition vehicles with direct fuel injection system -09-26 by Felix Köhler Institut für Fahrzeugtechnik und Mobilität Antrieb/Emissionen PKW/Kraftrad On behalf

More information

Performance of Batteries in Grid Connected Energy Storage Systems. June 2018

Performance of Batteries in Grid Connected Energy Storage Systems. June 2018 Performance of Batteries in Grid Connected Energy Storage Systems June 2018 PERFORMANCE OF BATTERIES IN GRID CONNECTED ENERGY STORAGE SYSTEMS Authors Laurie Florence, Principal Engineer, UL LLC Northbrook,

More information

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill

Test report P E. J. Magner Dipl.-Ing. (FH) N. Machill Kiwa Polymer Institut GmbH Quellenstraße 3 D-65439 Flörsheim-Wicker Tel. +49 (0)61 45-5 97 10 Fax +49 (0)61 45-5 97 19 www.kiwa.de Test report P 8464-2-E Testing order: Tests on the coating Wecryl 124

More information

July 10, Refer to: HSA-10/CC-78A

July 10, Refer to: HSA-10/CC-78A July 10, 2003 Refer to: HSA-10/CC-78A Barry D. Stephens, P.E. Senior Vice President of Engineering ENERGY ABSORPTION Systems, Inc. 3617 Cincinnati Avenue Rocklin, California 95765 Dear Mr. Stephens: Your

More information

KWA. Evaluation of the Vaporless Manufacturing LD 3000 and LD 3000S Mechanical Line Leak Detector on Large Rigid and Flexible Pipelines.

KWA. Evaluation of the Vaporless Manufacturing LD 3000 and LD 3000S Mechanical Line Leak Detector on Large Rigid and Flexible Pipelines. Evaluation of the Vaporless Manufacturing LD 3000 and LD 3000S Mechanical Line Leak Detector on Large Rigid and Flexible Pipelines (Addendum to the August 20, 1993 Evaluation of the Vaporless LD 3000 and

More information

This test report describes the test results of the below mentioned paragliding harness.

This test report describes the test results of the below mentioned paragliding harness. Test Report This test report describes the test results of the below mentioned paragliding harness. All the tests were carried out by: Air Turquoise SA, official test laboratory of Switzerland. Standards

More information

VITLAB Dispenser. Standard Operating Procedure (SOP)

VITLAB Dispenser. Standard Operating Procedure (SOP) VITLAB Dispenser Standard Operating Procedure (SOP) VITLAB GmbH Linus-Pauling-Str. 63762 Grossostheim Germany tel: +49 6026 97799-0 fax: +49 6026 97799-30 info@vitlab.com www.vitlab.com Table of contents.

More information

DRIVING STABILITY OF A VEHICLE WITH HIGH CENTRE OF GRAVITY DURING ROAD TESTS ON A CIRCULAR PATH AND SINGLE LANE-CHANGE

DRIVING STABILITY OF A VEHICLE WITH HIGH CENTRE OF GRAVITY DURING ROAD TESTS ON A CIRCULAR PATH AND SINGLE LANE-CHANGE Journal of KONES Powertrain and Transport, Vol. 1, No. 1 9 DRIVING STABILITY OF A VEHICLE WITH HIGH CENTRE OF GRAVITY DURING ROAD TESTS ON A CIRCULAR PATH AND SINGLE LANE-CHANGE Kazimierz M. Romaniszyn

More information

Translation of the Original operating instructions Lifting device Z 70 /...

Translation of the Original operating instructions Lifting device Z 70 /... Translation of the Original operating instructions Lifting device Z 70 /... Content 1. Lifting device / Correct use according to regulations 2. Basic principles 3. General information 4. Special remarks

More information

Test report. About the effect of Lambda System Cleaning Products. No

Test report. About the effect of Lambda System Cleaning Products. No Page 1 of 8 Test report About the effect of Lambda System Cleaning Products 0. Client Friedhofstr. 5 67127 Rödersheim-Gronau Germany 1. Task Formulation The effects of the cleaning characteristic of fuel/oil

More information

Evidence of performance Reduction of impact sound pressure level by floor coverings

Evidence of performance Reduction of impact sound pressure level by floor coverings Evidence of performance Reduction of impact sound pressure level by floor coverings Test report No. 14-003029-PR01 (PB X3.1-F03-04-en-01) Client Product Getzner Werkstoffe GmbH Herrenau 5 6706 Bürs Austria

More information

This test report describes the test results of the below mentioned paragliding harness. SUPAIR - VLD Delight 2 Medium 2.5 kg 120 kg Foam 15 cm ABS

This test report describes the test results of the below mentioned paragliding harness. SUPAIR - VLD Delight 2 Medium 2.5 kg 120 kg Foam 15 cm ABS Test Report This test report describes the test results of the below mentioned paragliding harness. All the tests were carried out by: Air Turquoise SA, official test laboratory of Switzerland. Standards

More information

SAE Baja - Drivetrain

SAE Baja - Drivetrain SAE Baja - Drivetrain By Ricardo Inzunza, Brandon Janca, Ryan Worden Team 11A Concept Generation and Selection Document Submitted towards partial fulfillment of the requirements for Mechanical Engineering

More information

KISSsoft Case Study on Gearing Optimization with the "Gearbox Variant Generator" KISSsoft Case Study on Gearing Optimization with the

KISSsoft Case Study on Gearing Optimization with the Gearbox Variant Generator KISSsoft Case Study on Gearing Optimization with the KISSsoft Case Study on Gearing Optimization with the "Gearbox Variant Generator" KISSsoft Case Study on Gearing Optimization with the "Gearbox Variant Generator" Dr. Ing. U. Kissling, KISSsoft AG, Hombrechtikon,

More information

Study of the Performance of a Driver-vehicle System for Changing the Steering Characteristics of a Vehicle

Study of the Performance of a Driver-vehicle System for Changing the Steering Characteristics of a Vehicle 20 Special Issue Estimation and Control of Vehicle Dynamics for Active Safety Research Report Study of the Performance of a Driver-vehicle System for Changing the Steering Characteristics of a Vehicle

More information

This test report describes the test results of the below mentioned paragliding harness. Ozone Gliders Ozium Medium 1.

This test report describes the test results of the below mentioned paragliding harness. Ozone Gliders Ozium Medium 1. Test Report This test report describes the test results of the below mentioned paragliding harness. All the tests were carried out by: Air Turquoise SA, official test laboratory of Switzerland. Standards

More information

Original. M. Pang-Ngam 1, N. Soponpongpipat 1. Keywords: Optimum pipe diameter, Total cost, Engineering economic

Original. M. Pang-Ngam 1, N. Soponpongpipat 1. Keywords: Optimum pipe diameter, Total cost, Engineering economic Original On the Optimum Pipe Diameter of Water Pumping System by Using Engineering Economic Approach in Case of Being the Installer for Consuming Water M. Pang-Ngam 1, N. Soponpongpipat 1 Abstract The

More information

Transport System. Telematics. Functioning of Digital Tachograph System in Country of UE

Transport System. Telematics. Functioning of Digital Tachograph System in Country of UE Archives of Volume 3 Transport System Issue 2 Telematics May 21 Functioning of Digital Tachograph System in Country of UE M. RYCHTER Motor Transport Institute 8 Jagiellońska St., PL-3-31 Warsaw EMAIL:

More information

CSC Transportation LLC Job Description Semi Tractor-Trailer Driver

CSC Transportation LLC Job Description Semi Tractor-Trailer Driver CSC Transportation LLC Job Description Semi Tractor-Trailer Driver Job Title: Driver of Semi Tractor-Trailer Terminal Reports to: Terminal Manager/Dispatcher/Operations Supervisor General Duties: Pick

More information

Tester for Motor-Driven Relays Type Siemens SICO 1225 M A N U A L

Tester for Motor-Driven Relays Type Siemens SICO 1225 M A N U A L Tester for Motor-Driven Relays Type Siemens SICO 1225 M A N U A L 8 Technical Data Operating temperature range 5 C 40 C Power supply 230 V, 50 Hz net Power input 25 W Protection degree IP 42 Protection

More information

This test report describes the test results of the below mentioned paragliding harness. Sup'Air Evo XC 3 Large 4.2 kg 120 kg Mousse bag ABS

This test report describes the test results of the below mentioned paragliding harness. Sup'Air Evo XC 3 Large 4.2 kg 120 kg Mousse bag ABS Test Report This test report describes the test results of the below mentioned paragliding harness. All the tests were carried out by: Air Turquoise SA, official test laboratory of Switzerland. Standards

More information

MEASURING CUSTOMER COMFORT OF THE SIDE DOOR SELF-EQUIPMENT FOR THE AUTOMOBILE INDUSTRY

MEASURING CUSTOMER COMFORT OF THE SIDE DOOR SELF-EQUIPMENT FOR THE AUTOMOBILE INDUSTRY MEASURING CUSTOMER COMFORT OF THE SIDE DOOR SELF-EQUIPMENT FOR THE AUTOMOBILE INDUSTRY Pavel BARTONÍČEK 1, Ivan MAŠÍN 2 1 Department of Machine Parts and Mechanism, Faculty of Mechanical Engineering Liberec

More information

Concrete (63) PROFICIENCY TESTING PROGRAM REPORT

Concrete (63) PROFICIENCY TESTING PROGRAM REPORT www.labsmartservices.com.au Concrete - 2016 (63) PROFICIENCY TESTING PROGRAM REPORT Accredited for compliance with ISO/IEC 17043 Copyright: LabSmart Services Pty Ltd Copyright: LabSmart Services Pty Ltd

More information

Development of Relief Valve Automatic assembly technology

Development of Relief Valve Automatic assembly technology Development of Relief Valve Automatic assembly technology Technology Explanation Development of Relief Valve Automatic assembly technology TAKIGUCHI Masaki Abstract Construction machinery is equipped with

More information

Operating Instructions Precision balance

Operating Instructions Precision balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating Instructions Precision balance KERN Version

More information

Excursion 2015 nach Heilbronn

Excursion 2015 nach Heilbronn Verband der Luftfahrtsachverständigen p.a.r.k. aviation german news Erscheinungsweise vierteljährlich 15. Jahrgang Preis 3,- EURO for law and maintenance Ausgabe: 3.2015 Ausgabe 39 3.2015 ISSN 1862-6815

More information

Contact person Date Reference Page Hans Eriksson F000838G 1 (4) Wood Technology

Contact person Date Reference Page Hans Eriksson F000838G 1 (4) Wood Technology issued by an Accredited Testing Laboratory Contact person Hans Eriksson 2015-03-26 5F000838G 1 (4) Wood Technology +46 10 516 54 28 hans.eriksson@sp.se 1002 ISO/IEC 17025 Nordic Comfort Products A/S P.O.

More information

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer A company of ThyssenKrupp Elevator ThyssenKrupp Aufzugswerke Operating Manual Oil buffer OPERATING MANUAL Printer s imprint All rights reserved. Copyright by: THYSSENKRUPP AUFZUGSWERKE GMBH P.O. box 23

More information

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE PRESSURE

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE PRESSURE CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE co 2 PRESSURE www.epluse.com calibration AT the highest level The National Metrological Institute (NMI) or its Designated Institutes

More information

Operating Manual TWN 0121/1. Lifting point, screw-type TWN 0122 TWN 0123 TWN 0127 TWN 1120 TWN 1830 TWN 1890

Operating Manual TWN 0121/1. Lifting point, screw-type TWN 0122 TWN 0123 TWN 0127 TWN 1120 TWN 1830 TWN 1890 TWN 0121/1 Operating Manual Lifting point, screw-type TWN 0122 TWN 0123 TWN 0127 TWN 1120 TWN 1830 TWN 1890 THIELE GmbH & Co. KG Werkstraße 3 Tel: +49 (0)2371 / 947-0 58640 Iserlohn www.thiele.de B07905-D

More information

Ch. 169 DIESEL SMOKE MEASUREMENT CHAPTER 169. DIESEL SMOKE MEASUREMENT PROCEDURE

Ch. 169 DIESEL SMOKE MEASUREMENT CHAPTER 169. DIESEL SMOKE MEASUREMENT PROCEDURE Ch. 169 DIESEL SMOKE MEASUREMENT 67 169.1 CHAPTER 169. DIESEL SMOKE MEASUREMENT PROCEDURE Sec. 169.1. Purpose. 169.2. Scope. 169.3. Definitions. 169.4. Smoke emission test. 169.5. Smoke test cycle. 169.6.

More information

This test report describes the test results of the below mentioned paragliding harness. Sup'Air Kinder S 2.1 kg 100 kg ABS

This test report describes the test results of the below mentioned paragliding harness. Sup'Air Kinder S 2.1 kg 100 kg ABS Test Report This test report describes the test results of the below mentioned paragliding harness. All the tests were carried out by: Air Turquoise SA, official test laboratory of Switzerland. Standards

More information

Three-phase motors for marine use

Three-phase motors for marine use Three-phase motors for marine use Contents Product description 11/2 Overview of technical data 11/7 Series K.../W4.. for Premium Efficiency IE3 11/8 Series K.../WE.. for High Efficiency IE2 11/12 Series

More information

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 * SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 * PRODUCT: Heavy Duty Stock Car Steel Wheels 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

OFS Brands Test Facility Report No: OFSB Date: April 2, 2015 Page: 1 of 29. Test Report For: ANSI/BIFMA X Storage Units.

OFS Brands Test Facility Report No: OFSB Date: April 2, 2015 Page: 1 of 29. Test Report For: ANSI/BIFMA X Storage Units. Date: April 2, 2015 Page: 1 of 29 Test Report For: ANSI/BIFMA X5.9-2012 Storage Units FastenLink This report shall not be reproduced, except in full, without written permission from OFS Brands Quality

More information

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1. Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.3, 5/16/18 1.0 Scope This document is currently limited in scope to inverter interfaced PV installations

More information

Test report No

Test report No Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2016-1390

More information

Test Based Optimization and Evaluation of Energy Efficient Driving Behavior for Electric Vehicles

Test Based Optimization and Evaluation of Energy Efficient Driving Behavior for Electric Vehicles Test Based Optimization and Evaluation of Energy Efficient Driving Behavior for Electric Vehicles Bachelorarbeit Zur Erlangung des akademischen Grades Bachelor of Science (B.Sc.) im Studiengang Wirtschaftsingenieur

More information

SUMMARY. St-jean-sur-richelieu, January 15th 2016 Client: America s heat Project: PI-20114

SUMMARY. St-jean-sur-richelieu, January 15th 2016 Client: America s heat Project: PI-20114 SUMMARY 1 Introduction... 4 1.1 General... 4 1.2 Test unit information... 4 1.3 Results... 4 1.4 Pretest information... 4 2 Summary of test results... 5 2.1 table 1A: Data Summary Part A... 5 2.2 table

More information

Product Loss During Retail Motor Fuel Dispenser Inspection

Product Loss During Retail Motor Fuel Dispenser Inspection Product Loss During Retail Motor Fuel Dispenser Inspection By: Christian Lachance, P. Eng. Senior Engineer - ment Engineering and Laboratory Services ment Canada Date: Product Loss During Retail Motor

More information

Worker Crushed by Vessel Date of Incident: August 3, 2007 Type of Incident: Fatal

Worker Crushed by Vessel Date of Incident: August 3, 2007 Type of Incident: Fatal Worker Crushed by Vessel Date of Incident: August 3, 2007 Type of Incident: Fatal TABLE OF CONTENTS SECTION TITLE PAGE 1.0 DATE AND TIME OF INCIDENT 4 2.0 NAME & ADDRESS OF PRINCIPAL PARTIES 4 2.1 Employer

More information

Test report No

Test report No Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report No. 2015-1661

More information

TEST REPORT. No. 284a/14

TEST REPORT. No. 284a/14 Labor für Umwelterprobung und Werkstoffprüfung Telefon +49 (0) 3 41 / 4 84 32-25 Telefax +49 (0) 3 41 / 4 84 32-14 E-Mail umwelterprobung@tzoleipzig.de Technologie-Zentrum für Oberflächentechnik und Umweltschutz

More information

Test report no

Test report no Exova Warringtonfire, Frankfurt Industriepark Höchst, C369 Frankfurt am Main D-65926 Germany T : +49 (0) 69 305 3476 F : +49 (0) 69 305 17071 E : EBH@exova.com W: www.exova.com Test report no. 2015-1339

More information

The stability tests that are described below are performed according to and with compliance with 2

The stability tests that are described below are performed according to and with compliance with 2 Purpose of experiment: The stability tests that are described below are performed according to and with compliance with 2 standards, namely NSF49:2002 (19 March) and UL 61010A-1 2002 (April 30). These

More information

This test report describes the test results of the below mentioned paragliding harness. SUP'AIR Walibi 2 Medium 3.3 kg 100 kg Air bag ABS

This test report describes the test results of the below mentioned paragliding harness. SUP'AIR Walibi 2 Medium 3.3 kg 100 kg Air bag ABS Test Report This test report describes the test results of the below mentioned paragliding harness. All the tests were carried out by: Air Turquoise Para-test, official test laboratory of Switzerland Standards

More information

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number: Inspection Report Referred to: AAMA 2604-13, Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminium Extrusions and Panels Coating name:

More information

Robots. KUKA Roboter GmbH. LBR iiwa. LBR iiwa 7 R800, LBR iiwa 14 R820 Specification. LBR iiwa. Issued: Version: Spez LBR iiwa V7

Robots. KUKA Roboter GmbH. LBR iiwa. LBR iiwa 7 R800, LBR iiwa 14 R820 Specification. LBR iiwa. Issued: Version: Spez LBR iiwa V7 Robots KUKA Roboter GmbH LBR iiwa LBR iiwa 7 R800, LBR iiwa 14 R820 Specification LBR iiwa Issued: 23.05.2016 Version: Spez LBR iiwa V7 Copyright 2016 KUKA Laboratories GmbH Zugspitzstraße 140 D-86165

More information

Report Test Report

Report Test Report ÖTI Institut für Ökologie, Technik und Innovation GmbH Report 70535 Test Report Applicant FIDIVI Tessitura Vegnano S.p.A. Regione Masio 19 / bis 10046 Poirino (TO) ITALIEN Reference Mr. Alessandro Avenati

More information

Charging of HOPPECKE OPzV solar.power battery in Solar Applications

Charging of HOPPECKE OPzV solar.power battery in Solar Applications Charging of HOPPECKE OPzV solar.power battery in Solar Applications Preface: This document provides hints for charging of HOPPECKE OPzV solar.power battery cells and blocs in solar applications. Note:

More information

Influential Criteria on the Optimization of a Gearbox, with Application to an Automatic Transmission

Influential Criteria on the Optimization of a Gearbox, with Application to an Automatic Transmission Influential Criteria on the Optimization of a Gearbox, with Application to an Automatic Transmission Peter Tenberge, Daniel Kupka and Thomas Panéro Introduction In the design of an automatic transmission

More information

White paper: Pneumatics or electrics important criteria when choosing technology

White paper: Pneumatics or electrics important criteria when choosing technology White paper: Pneumatics or electrics important criteria when choosing technology The requirements for modern production plants are becoming increasingly complex. It is therefore essential that the drive

More information

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009

Dispensette. Testing Instructions (SOP) 1. Introduction. May 2009 Dispensette Testing Instructions (SOP) May 2009 1. Introduction The standard ISO DIS 8655 describes both the design and the testing of the bottle-top dispenser. The following Testing Instructions describe

More information

Assessment of Elevator and Escalator Maintenance & Repair Program Final Elevator Audit Submission Foggy Bottom Station - Escalator C04X03 (Entrance)

Assessment of Elevator and Escalator Maintenance & Repair Program Final Elevator Audit Submission Foggy Bottom Station - Escalator C04X03 (Entrance) Foggy Bottom Station - Escalator C04X03 (Entrance) 217 Foggy Bottom Station - Escalator C04X04 (Platform) Foggy Bottom Station Escalator C04X04 (Platform) Escalator Audit Equipment Description The escalator

More information

GMD 13 New gravimetric measuring system with evaluation on location

GMD 13 New gravimetric measuring system with evaluation on location Dr. Födisch Umweltmesstechnik AG Zwenkauer Strasse 159 04420 Markranstädt Germany Phone: +49 34205 755-0 Fax: +49 34205 755-40 E-mail: sales@foedisch.de Internet: www.foedisch.de GMD 13 New gravimetric

More information

Demonstration with optical fibres by Smart Fibres Ltd. Task 15

Demonstration with optical fibres by Smart Fibres Ltd. Task 15 Demonstration with optical fibres by Smart Fibres Ltd. Task 15 Dutch Offshore Wind Energy Converter project DOWEC 10021 rev1 Name: Signature: Date: Written by: J.F. Kooij (LMGH) 30-09-03 version Date No

More information

Test of the validity of RVS-technology gel

Test of the validity of RVS-technology gel Project report: REWITEC GmbH Cranachstraße 7 D-35578 Wetzlar Test of the validity of RVS-technology gel Prepared in December 2003 by: MSc-Eng. Markus Haid 1 Table of contents 1 Table of contents 2 Summary

More information

This test report describes the test results of the below mentioned paragliding harness.

This test report describes the test results of the below mentioned paragliding harness. Test Report This test report describes the test results of the below mentioned paragliding harness. All the tests were carried out by: Air Turquoise SA, official test laboratory of Switzerland. Standards

More information

Case Study Involving Surface Durability and Improved Surface Finish

Case Study Involving Surface Durability and Improved Surface Finish Case Study Involving Surface Durability and Improved Surface Finish G. Blake and J. Reynolds (Printed with permission of the copyright holder, the American Gear Manufacturers Association, 500 Montgomery

More information

ME201 Project: Backing Up a Trailer Using Vector Analysis

ME201 Project: Backing Up a Trailer Using Vector Analysis ME201 Project: Backing Up a Trailer Using Vector Analysis Assigned date: January 26, 2018 Due date: March 16, 2018 INTRODUCTION Many drivers use a trial-and-error approach when they back up a vehicle with

More information

A New verification system of mobile scales

A New verification system of mobile scales XX IMEKO World Congress Metrology for Green Growth September 9 14, 212, Busan, Republic of Korea A New verification system of mobile scales Yao Jinhui 1,Li Qingzhong 2 /Presenter,Xu Hang 3,Li Haigen 4

More information

Steering Actuator for Autonomous Driving and Platooning *1

Steering Actuator for Autonomous Driving and Platooning *1 TECHNICAL PAPER Steering Actuator for Autonomous Driving and Platooning *1 A. ISHIHARA Y. KUROUMARU M. NAKA The New Energy and Industrial Technology Development Organization (NEDO) is running a "Development

More information

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT Date of publication: 1 November 2016Not yet published Issued by: Mark Wogan, Manager Energy Safety WorkSafe New ZealandNot yet issued Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

More information

This test report describes the test results of the below mentioned paragliding harness. Dudek Paragliders Pogo 2 Medium 5.

This test report describes the test results of the below mentioned paragliding harness. Dudek Paragliders Pogo 2 Medium 5. Test Report This test report describes the test results of the below mentioned paragliding harness. All the tests were carried out by: Air Turquoise SA, official test laboratory of Switzerland. s Tests

More information

Report Turbine inspection WTG 12801, Oudelandertocht 11

Report Turbine inspection WTG 12801, Oudelandertocht 11 Report Turbine inspection WTG 12801, Oudelandertocht 11 Report No. V662015041 09-11-2015 Contents 1 Purpose... 3 2 Abbreviations... 3 3 General information... 4 4 Wind turbine main components... 4 5 Documents...

More information

PVP Field Calibration and Accuracy of Torque Wrenches. Proceedings of ASME PVP ASME Pressure Vessel and Piping Conference PVP2011-

PVP Field Calibration and Accuracy of Torque Wrenches. Proceedings of ASME PVP ASME Pressure Vessel and Piping Conference PVP2011- Proceedings of ASME PVP2011 2011 ASME Pressure Vessel and Piping Conference Proceedings of the ASME 2011 Pressure Vessels July 17-21, & Piping 2011, Division Baltimore, Conference Maryland PVP2011 July

More information