Benefits of an air preheater replacement. Benefits of an air preheater replacement unit in a large CDU furnace
|
|
- Hugh Summers
- 6 years ago
- Views:
Transcription
1 Benefits of an air preheater replacement unit in a large CDU furnace
2 Content 1) Existing situation 2) Design criteria 3) Replacement 4) Results
3 Content 1) Existing situation 2) Design criteria 3) Replacement 4) Results
4 Actual process flow Duty 13,9 MW 3 heaters B-Damper kg/h 445 C Stack kg/h 225 C APH-A APH-B Furnace 275 C
5 Furnace of 170 MW, 2 DEKA APH s with both 14 MW duty
6 Content 1) Existing situation 2) Design criteria 3) Replacement 4) Results
7 Check of design data according to operation FGI: 445 C FGO: 300 C O2 out of furnace: 3%, wet DT-Air: 190 C
8 Check of design data according to operation 170 MW
9 100% - Furnace efficiency in % Benefits of an air preheater replacement New flue gas exit temperature target for the new APH Stack temp. in C Furnace efficiency Lowering the stack temperature by 140 C would save about 7% fuel.
10 Check stack conditions, worst case 67 kg/s, 283 C 67 kg/s, 173 C Acid DP: 135 C 110m Draft: 6 mbar Acid DP: 135 C 110m Draft: 5 mbar 3 other heaters: C 1% H2S max. 300 C CDU4 heater 3 other heaters: 189 C 50 kg/s, 300 C C 100 ppm H2S 1% H2S max. CDU4 heater 50 kg/s, 154 C 100 ppm H2S BEFORE AFTER
11 Check ID-fan conditions With lower flue gas flow rate passing through ID-Fan, higher pressure increase can be used without reducing safety margin.
12 Design parameters of new APH Stack kg/h 445 C 7 mbar 154 C Furnace 364 C 5 mbar kg/h 16 C 16 C Combustion Air
13 Hot Air Recirculation for air preconditioning Stack kg/h 445 C 144 C Furnace 353 C kg/h 19 C -10 C 8 % HAR
14 Cold Air Bypass for performance adjustment Stack kg/h 475 C 183 C Furnace 352 C 389 C kg/h 16 C 10% CAB
15 Advantage of HAR vs. CAB For equal metal skin temperature, HAR offer 34 C hotter air, equivalent to 2,2 MW duty (difference between +25 and -10 C).
16 Air temperature, C Benefits of an air preheater replacement Advantage of HAR vs. CAB /11/ :00 07/11/ :00 09/11/ :00 11/11/ :00 13/11/ :00 15/11/ :00 17/11/ :00 19/11/ :00 21/11/ :00 Date Air inlet temperature is not depending of outside conditions, less fouling and less condensation in the air preheater. HAR AMB
17 Air Preheater selection Counter flow plates Fully welded High efficient Compact and light
18 Material selection Because of acid dew point being higher than the cold end metal temperature of the heat exchanger, a plate made from SS304 has been chosen: Cr-content: 17,0-18,5 % Ni-content: 8,5-10,5 % Cold end temperature approx. 83 C
19 Acid Dew point C Benefits of an air preheater replacement Material selection dew point consideration ,000 10,000 SO2 content, ppm ADP-10 Vol % H2O ADP-20 Vol % H2O Depending on H2S in the fuel (from few ppm to 100 ppm) the dew point can vary from 73 to 107 C (VDI 4760)
20 Content 1) Existing situation 2) Design criteria 3) Replacement 4) Results
21 Pre-assembly in largest possible components, with insulation
22 Transport by ship
23 Dismantling of old units within 3 days
24 Removal of the old DEKA-type APH: weight approx. 65 to.
25 Dismantling of old installation The old APH unit has been completely removed
26 Placing the new air plenum on the prepared structure requires a high degree of accuracy.
27 Installing the new APH: weight of only 42 tons with higher performance than the original.
28 Ready for start-upon the 1 st of November 2011
29 New APH Layout Benefits of an air preheater replacement
30 Content 1) Existing situation 2) Design criteria 3) Replacement 4) Results
31 Flue gas outlet temperature ( C) Benefits of an air preheater replacement Flue gas outlet temperature /10/ :00 13/11/ :00 03/12/ :00 23/12/ :00 12/01/ :00 01/02/ :00 21/02/ :00 Date Flue gas outlet temperature decreased from 310 C to 166 C
32 Air outlet temperature of APH, C Benefits of an air preheater replacement Hot air outlet temperature Average Temp before replacement /10/ :00 13/11/ :00 03/12/ :00 23/12/ :00 12/01/ :00 01/02/ :00 21/02/ :00 Date Hot air outlet temperature average of 356 C after start-up.
33 Heat efficiency oin % Benefits of an air preheater replacement Heater efficiency /11/ :00 08/11/ :00 13/11/ :00 18/11/ :00 23/11/ :00 28/11/ :00 03/12/ :00 08/12/ :00 13/12/ :00 Date Heater efficiency increase from 81,2% to 90,1%
34 Duty / Throughput, MW / m3/hr Duty / Throughput ratio 0.25 Benefits of an air preheater replacement /10/ :00 13/11/ :00 03/12/ :00 23/12/ :00 12/01/ :00 01/02/ :00 21/02/ :00 Date Duty / throughput ratio reduction from 0,126 MW/m3/hr by 22% to 0,098 MW/m3hr. (average throughput of 1110 m3/h)
35 NOX, corrected, mg/nm3 Benefits of an air preheater replacement NOx increase Limit Nox range in /10/ :00 13/11/ :00 03/12/ :00 23/12/ :00 12/01/ :00 01/02/ :00 21/02/ :00 Date NOx increase prediction to mg/nm3 in line with API 535, fig. 9. Then back to range of mg/n3 after burner adjustment. 2011
36 Summary Reduction of the flue gas outlet temperature by 144 C. Increased of Air temperature to burners by 151 C. Increase of heater efficiency by 8,9% point. Reduction of duty/throughput ratio by 22% (0,028 MW/m3/hr) Saving of approx. 10,1 MW at current average heater duty of 114 MW. CO 2 saving of to/year Fuel saving of 855 Nm3/h. Payback less than 2 years based on fuel saving based on current average firing duty.
37 Questions?
38 Thank you for your Attention BD-Heat Recovery Inc. Dr. Olivier Brasseur
The Practical Uses of Computational Fluid Dynamics Not Just a Pretty Picture
The Practical Uses of Computational Fluid Dynamics Not Just a Pretty Picture Presenter: William Osley Company: CALGAVIN Ltd Email: william.osley@calgavin.com Page 1 Contents: Introduction Case Study 1:
More informationIncreased flexibility of refineries by O 2 enrichment. Sulphur recovery and new opportunities.
Increased flexibility of refineries by O 2 enrichment. Sulphur recovery and new opportunities. Janusz Kertynski, Dr Bernhard Schreiner Budapest, 13-14 October 2015 1 The Linde Group 2 Actual needs of refining
More informationThe World s First Flameless Crude Heater
AFRC 2013 Industrial Combustion Symposium Kauai, HI September 23-25, 2013 The World s First Flameless Crude Heater Great Southern Flameless, LLC Presented by Great Southern Flameless, LLC GSF One of the
More informationDoing more for clean environment and energy saving
Doing more for clean environment and energy saving Rütli Burners Switzerland AG is a worldwide leading industrial burner solution supplier. Our head quarter is located in Schaffhausen, Switzerland one
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG)
MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS VHF-ABP (BECKETT AFG) VHF-ANP / VHF-ANE (BECKETT NX) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS THV1C072A948SA (BECKETT AFG)
MODEL NO. THV1C072A948SA (BECKETT AFG) THV1C072A9V4SA (BECKETT AFG) HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000
More informationNOx-Beta Ultra Low NOx Burners
NOx-Beta Ultra Low NOx s February NOx-Beta Features Ultra low NOx without any performance loss Staged air principle no external NOx reducing devices or FGR needed Robust, well engineered construction Cost
More informationR&D on Oil-Burning, Environment - Friendly, High-Efficiency Boiler
2001.M4.3.1 R&D on Oil-Burning, Environment - Friendly, High-Efficiency Boiler (Environment-Friendly, High-Efficiency Boiler Group) Takashi Murakawa, Hiroshi Kato, Hiroshi Matsumoto, Kentaro Sato, Yasuhiro
More informationLow NOx Technology Seminar. The Gas Company April 30 th, 2003 Downey,CA. Presentation Overview
Low NOx Technology Seminar Sponsored by The Gas Company April 30 th, 2003 Downey,CA David Thornock Presentation Overview Who is Overview of the FIR Burner Burner design Demonstrations and Installations
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY VLF-CBP (Front Flue) or VLR-CBP (Rear Flue) High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED LOWBOY FURNACE SPECIFICATIONS MODEL NO. HEATING CAPACITY High Fire Med-High Fire Med-Low Fire [5] Low Fire High Fire Med-High Fire Med-Low Fire [5] Low Fire HEAT INPUT RATE (BTUH) 140,000 119,000
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000 OUTPUT BTUH
More informationCommencement of the Commercial Operation of 600 MW Unit, "Hirono No. 5 Thermal Power Station of The Tokyo Electric Power Co., Inc.
Commencement of the Commercial Operation of 600 MW Unit, "Hirono No. 5 Thermal Power Station of The Tokyo Electric Power Co., Inc." HIROMASA MOMMA* 1 TAKAYUKI SUTO* 1 RYUJI IWAMOTO* 3 JUNICHI ISHIGURO*
More informationExperimental Investigation of Catalyst Deactivation Below the MOT and Full Load Regeneration
Experimental Investigation of Catalyst Deactivation Below the MOT and Full Load Regeneration S. Bogseth, B. Spang, T. Martz, L. Muzio Fossil Energy Research Corp. Laguna Hills, CA R. Himes Electric Power
More informationIED RELATING TO OIL AND GAS BURNERS FOR INDUSTRIAL USE
IED RELATING TO OIL AND GAS BURNERS FOR INDUSTRIAL USE Nigel Webley Group Technical Director Hamworthy Combustion Tel: 01202 662754 E-mail: nwebley@hamworthy-combustion.com Website: www.hamworthy-combustion.com
More informationGAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS
GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. CMC1-50D36 (DV3) CMC1-75D36 (DV3) HEAT INPUT RATE (BTUH) 50,000 75,000 OUTPUT (BTUH)
More informationMECHANISM OF NOx CONTROL
MECHANISM OF NOx CONTROL SC/EEC Seminar/22 nd April,2016 1 2. Concept MECHANISM OF NOx CONTROL NOx generation in the coal fired boiler? Thermal NOx and Fuel NOx are the main factors of NOx generation...
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
MODEL NO. VL8FA119P60B / VL8RA119P60B (BECKETT AFG) HEATING CAPACITY High Fire * Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 OUTPUT BTUH 1 132,000 119,000 101,000 SEASONAL EFFICIENCY
More informationBoiler Optimization and MATS Work Practices Requirements. McIlvaine Hot Topics September 27 th, 2013
Boiler Optimization and MATS Work Practices Requirements McIlvaine Hot Topics September 27 th, 2013 Mercury and Air Toxics Standard (MATS) Requires all plants to reduce mercury and increase efficiency
More informationCombustion Optimization of Panshan Unit 4 for Energy Savings & NO x Emissions Reduction
Combustion Optimization of Panshan Unit 4 for Energy Savings & NO x Emissions Reduction A&WMA International Specialty Conference May 10-14, 2010 Xi'an, Shaanxi Province, China Energy Research Center, Lehigh
More informationGREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER
TECHNICAL MANUAL GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER GREENOx/GREENOx.e/K WITH THREE GAS PASSES DUAL GRX/DUAL GRX.e THREE GAS
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. OIL FIRED UPFLOW FURNACE SPECIFICATIONS HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000 OUTPUT BTUH
More informationBENCHMARKING SO 3 REMOVAL THE CLEANSTACK PROCESS
BENCHMARKING SO 3 REMOVAL THE CLEANSTACK PROCESS Ms. Amy P Evans* Director of Technology, Marsulex Environmental Technologies Inc. LLC, 200 North Seventh Street, Lebanon, PA 17046 Mr. Joseph A. Gresh Senior
More informationZEECO BURNER DIVISION
ZEECO BURNER DIVISION Enhanced Jet Flat Flame Burners GLSF Series 22151 EAST 91ST STREET BROKEN ARROW OK 74014 USA +1-918-258-8551 SALES@ZEECO.COM ZEECO.COM INTRODUCTION: This document discusses the advantages
More informationGAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS
GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS MODEL NO. HEAT INPUT RATE (BTUH) OUTPUT (BTUH) 1 SEASONAL EFFICIENCY 2 LARGEST REC A/C 3 FUEL
More informationFULL AUTO TEMPERATURE CONTROL GENERAL 1. SPECIFICATIONS FULL AUTO TEMPERTURE CONTROL REXTON
02-3 FULL AUTO TEMPERATURE CONTROL GENERAL 1. SPECIFICATIONS 02-4 OVERVIEW AND OPERATION PROCESS 1. FATC SYSTEM LAYOUT Configuration and Characteristic of A/C Controller 02-5 A/C System Related Devices
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. OL6*A072D48/DV5 B OL6*A072D48/DV5 R OL6*A072D48/DV5 C HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. VH8FA119P60B VH8FA119T60B (BECKETT AFG) HEATING CAPACITY High Fire * Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 OUTPUT BTUH 1 132,000 119,000 101,000 SEASONAL EFFICIENCY
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 106,250 85,000 70,000 106,250 85,000 70,000
More informationQTY PART # DESCRIPTION. N/A PC USB Interface - Diagnostic kit N/A Thermo 90 diagnostic adaptor N/A N/A N/A
Category: Heater Document Number: PI055BC Date Posted: 6/28/2011 Rev. 03/2018 Description: Suggested Inventory List TOOLS FOR SERVICING WEBASTO HEATING SYSTEMS DBW SERIES AIR TOP & THERMO SERIES N/A 310646
More informationECONOMATIC STEEL SHELL BOILERS
ECONOMATIC STEEL SHELL BERS ECONOMATIC SERIES Since 1985 Stokvis has been supplying high quality products to the heating industry. The Economatic boilers are no exception.they are 3 pass reverse fl ame,
More informationOIL FIRED LOWBOY FURNACE SPECIFICATIONS
OIL FIRED BOY FURNACE SPECIFICATIS MODEL NO. HEATING CAPACITY TLF1M087C942SA TLR1M087C942SA High Fire Med-High Fire (BECKETT AFG) Med-Low Fire [5] Low Fire High Fire Med-High Fire TLF1M087D9V5SA [6] TLR1M087D9V5SA
More informationReal-life emission of automatically stoked biomass boilers
Real-life emission of automatically stoked biomass boilers Christoph Schmidl Joachim Kelz, Franziska Klauser, Vijay Kumar- Verma, Manuel Schwabl, Markus Schwarz Introduction: General Biomass combustion
More information\Performance of the Regenerative Burners in BaoSteel 2050 Hot Strip Mill Furnace Baoshan, China
\Performance of the Regenerative Burners in BaoSteel 2050 Hot Strip Mill Furnace Baoshan, China Steven J. O'Connor, Applications Engineer, Bloom Engineering Company Jian Cao Qin, Production Engineer Bao
More informationWorldwide Pollution Control Association
Worldwide Pollution Control Association IL Regional Technical Seminar September 13-15,211 Visit our website at www.wpca.info Babcock Power Inc. The Future Of Coal Fired SCRs In A Carbon Capture World 211
More informationCapacities and Operating Data
CROSSFIRE Line Burner Page 5603 Capacities and Operating Data Performance Data Lineal heat release at high fire Minimum lineal heat release Btu/hr/f t 1,000,000 1,250,000 1,500,000 1,750,000 2,000,000
More informationCatalytic Combustor for Ultra-Low NOx Advanced Industrial Gas Turbines
Catalytic Combustor for Ultra-Low NOx Advanced Industrial Gas Turbines March 12-14, 2002 Microturbine & Industrial Gas Turbines Peer Review Meeting Fairfax, VA Solicitation No:DE-SC02-00CH11000 Dr. Shahrokh
More informationOIL FIRED UPFLOW FURNACE SPECIFICATIONS
MODEL NO. HEATING CAPACITY High Fire Med Fire Low Fire High Fire Med Fire Low Fire High Fire Med Fire Low Fire HEAT INPUT RATE (BTUH) 156,250 140,000 119,000 156,250 140,000 119,000 156,250 140,000 119,000
More informationProSimTechs PROCESS SIMULATION TECHNICS
PROCESS SIMULATION TECHNICS Rigorous Process Simulation Services for the Vegetable oils & Fats refining industry (Degumming - Neutralising Bleaching Deodorising/Physical Refining) Deodorising and Physical
More informationRetrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen
Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung Dr.-Ing. Marco Derksen Contents NOx formation In-furnace NOx reducing measures Application of premixed combustion Experiences in
More informationMulti-Pollutant Catalyst for Combustion Turbine Power Plants
Multi-Pollutant Catalyst for Combustion Turbine Power Plants Christopher J. Bertole, Ph.D.* Brian Helner Cormetech, Inc. François Gressier ENGIE North America, Inc. Neal Coffey * * presenting authors Presentation
More informationIgnition Reliability in SGT-750 for Gas Blends at Arctic Conditions. Magnus Persson Combustion Expert / Distributed Generation / Sweden
Ignition Reliability in SGT-750 for Gas Blends at Arctic Conditions Magnus Persson Combustion Expert / Distributed Generation / Sweden siemens.com/power-gas Table of content Objectives of the Project SGT-750
More information1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER
CAPABILITIES Industry leading low NOx emissions High momentum. luminous flames at all furnace temperatures High release rates with moderate main combustion air pressure Good turndown with flame characteristics
More informationPower Generation Services Solutions for challenging Markets
Power Generation Services Solutions for challenging Markets Philipp Leifeld, GT Service Engineering / Dirk Kampe Marketing GT Modernizations & Upgrades Matthias Migl, Principal Key Expert Overall Plant
More informationGLOBAL SECURITY SYSTEM
GSX STEAM BOILER GLOBAL SECURITY SYSTEM Comprehensive security system, designed and built to ensure the overall operation safety of steam generators, in line with the new CE directive concerning the conduction
More informationFuels, Combustion and Environmental Considerations in Industrial Gas Turbines - Introduction and Overview
Brian M Igoe & Michael J Welch Fuels, Combustion and Environmental Considerations in Industrial Gas Turbines - Introduction and Overview Restricted Siemens AG 20XX All rights reserved. siemens.com/answers
More informationA95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS
Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for
More informationPortable TOC Analyser for Stack Emissions
Portable TOC Analyser for Stack Emissions Lightweight, compact, safe and SMART Size and Weight SPECIFICATIONS 355(W) x 155(H) x 426(D) mm, 10 Kg (with batteries 13,4 Kg) Power Supply External Power Adapter
More informationULTRA LOW NOx ATMOSPHERIC VENT WATER HEATER
COMMERCIAL GAS REPLACEMENT PARTS LIST ULTRA LOW NOx ATMOSPHERIC VENT WATER HEATER U65L(155,199,270)E*N(A) U100L(199,270,300,399)E*N(A) Includes Hydrojet Total Performance System Effective: August, 2012
More informationFroling Biomass boilers & technologies
Froling Biomass boilers & technologies Commercial wood chip / pellets boilers Turbomat 500 (1,7MBtu/h) Controls SPS 4000 (PLC) Universal industry standard expandable Screw/hyraulic feed Fuel: pellet /
More informationOptimize Energy Recovery in Refineries. Copyright : Evae Andersson
Optimize Energy Recovery in Refineries Copyright : Evae Andersson The material in this presentation may not be reproduced or transmitted in any form without the permission of the copyright holder. Alfa
More informationEclipse Vortometric Burners Series HI
Version Burner Model Parameter 6V 8V V V V 6V 8V V V 8V 3V 36V Max. Input MM BTU/hr (MW) (.8).5 (3.) 7 (5.0) 3 (6.7) 3 (9.) () (6.) 78 (3) 90 (6) 5 (37) (7) (6) Min. Input MM BTU/hr (MW) (Natural Gas)
More informationReplacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev W
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Armor Condensing Water Heater AW 151 thru 801 41 4 10 38
More informationGAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign
3450 RPM Motor, squirrel cage blower, panel with 2 lights (power and main fuel) and control switch Gas electric pilot and gas ignition transformer Leakage test cock, pilot cock and main gas cock Pilot
More informationDiagnostic Tools for Gas Turbine CO and SCR Systems
Diagnostic Tools for Gas Turbine CO and SCR Systems L. J. Muzio, R. A. Smith Fossil Energy Research Corp. Laguna Hills, CA Reinhold 216 NO x -Combustion Round Table February 1, 216 Orlando, Florida Simple
More informationREX/REX F/REX K/REX K F REX DUAL/REX DUAL F
TECHNICAL MANUAL REX/REX F/REX K/REX K F REX DUAL/REX DUAL F PRESSURISED STEEL BOILERS INDEX 1 GENERAL WARNINGS... 4 2 TECHNICAL SPECIFICATIONS... 5 2.1 REX/REX K/REX F/REX K F 7-130 BOILER... 5 2.2 REX/REX
More informationEmission Reduction Program (ERP) For Existing Pulverized Fuel Fired Thermal Power Plants
Emission Reduction Program (ERP) For Existing Pulverized Fuel Fired Thermal Power Plants Stochiometric combustion through Coal Mass Flow Balancing & Online Unburnt Carbon In Ash Measurement Anup Shukla
More informationBoilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97
RULE 425.2 Boilers, Steam Generators, and Process Heaters (Oxides of Nitrogen) - Adopted 10/13/94, Amended 4/6/95, 7/10/97 I. Purpose The purpose of this Rule is to limit oxides of nitrogen (NOx) emissions
More informationRemedy: Use a PC, check the accuracy of the signal, check external temperature sensor, check the wiring, check the connectors.
MAN TRUCK FAULT CODES CONDITIONER WITH ELECTRONIC CONTROL https://truck-manuals.jimdo.com/man-fault-codes/man-fault-codes-ac/ Code Description 3000 Outside temperature sensor Cause: faulty external temperature
More informationChinook Gas Furnace Multi-Position High Efficiency Condensing Furnace
Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace 1 stage PSC CXX-1-D 1 stage ECM CXX-1-X 2 stage PSC CXX-2-D 2 stage ECM CXX-2-V Modulating CXX-M-V, CXX-M-S Modulating Compact CC15-M-V
More informationAutomatic CFD optimisation of biomass combustion plants. Ali Shiehnejadhesar
Automatic CFD optimisation of biomass combustion plants Ali Shiehnejadhesar IEA Bioenergy Task 32 workshop Thursday 6 th June 2013 Contents Scope of work Methodology CFD model for biomass grate furnaces
More informationRarely Acknowledged Energy Benefits of Sulphur Recovery. Sulphur 2016 London, UK November 9, 2016
Rarely Acknowledged Energy Benefits of Sulphur Recovery Sulphur 2016 London, UK November 9, 2016 AGENDA AGENDA INTRODUCTION CRUDE OIL PRICE $140 $130 $120 $110 Crude Oil Price (US Dollars per Barrel) $100
More informationBFC Cyclone Condensing Glass-Lined Water Heater
ondensing Glass-Lined ater eater BF - 28/0/0/0/80/100/120 Fully room-sealed condensing high-efficiency water heater 97% (gross) utomatic gas/air premix burning system including burner modulation elivered
More informationPower Direct Vent PDV T Model
REPLACEMENT PARTS LIST Power Direct Vent PDV T Model Includes Hydrojet Sediment Reduction System Effective: January, 2012 ECO 7731 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING REPLACEMENT
More informationOil, gas and dual fuel burners. Burner series
Oil, gas and dual fuel burners Burner series 350...450 Group 4B Capacity 700-5500 kw 1 2 Table of contents General 5 Light fuel oil burners 6 Dimensions and PI diagram 6 Technical data 7 Capacity/back
More information95 MW Wartsila Natural Gas Generator Power Plant
95 MW Wartsila Natural Gas Generator Power Plant Plant comprises of (12) 8730 KW Wartsila, 20V34SG Natural Gas Engines and ABB Alternators, Fuel: Natural Gas, Year /2009, 11 KV, 50 HZ, Complete plant with
More informationCombustion and Boiler Performance Assessment of Kardia Power Plant
Combustion and Boiler Performance Assessment of Kardia Power Plant Dr. M. Michel, I. Tsolakidis DEBCO Final Conference Brussels, December 10, 2012 Thermal Calculation of the Boiler Boiler design 100%-Load
More informationFD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP
FD68 Series Axial-Flow Packaged Burners MODELS: FD68 / FD68-LN / FD68-RF SIZE RANGE: 50-1,500 HP Features of the FD68 Series RUGGED INDUSTRIAL DESIGN SUPERIOR HOUSING Cylindrical windbox design provides
More informationHeat Exchangers (Chapter 5)
Heat Exchangers (Chapter 5) 2 Learning Outcomes (Chapter 5) Classification of heat exchangers Heat Exchanger Design Methods Overall heat transfer coefficient LMTD method ε-ntu method Heat Exchangers Pressure
More informationINDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS
Operations and Maintenance Manual for INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS Models MD-25-OG MD-7500-OG December 2012 Copyright 2012 Periflame, Design Guide 113 Industrial Dual-Fuel Burners, 12/01/2012
More informationG95V Series Gas-Fired 95% 2-Stage High Efficiency (Condensing) Multi-Positional Furnace w/ ECM Circulator
5/23/07 G95V Service Parts 1 Key No. Description Cabinet Group Top Panel Left Side Panel Assembly Right Side Panel Assembly Rear Panel Blower Division Panel Assembly,,, Base Panel,, Upper Front Door Panel,
More informationSteam output 0.3 to 3.0 t/h Operating Pressure 10 to 16 bar
DATASHEET PSB SERIES Steam output 0.3 to 3.0 t/h Operating Pressure 10 to 16 bar Oil / Gas / HFO Fired Steam Boiler Three pass reverse flame steam boiler Without Economiser Maximum Permissible operating
More informationThermo 90 S.21 Diesel - 24 Volt
Coolant Heater Thermo 90 S.21 Diesel - 24 Volt Service Parts List for HMMWV (Humvee) 11/2012 P/N HMMWV Contents HMMWV - Thermo 90 S.21 Topic Heaters.........................................................................
More informationDevelopment of compact FC- and fuel processor based auxiliary power units using micro-channel reactor technique
Development of compact FC- and fuel processor based auxiliary power units using micro-channel reactor technique Institut für Mikrotechnik Mainz GmbH Dr. Gunther Kolb Head of Energy Technology and Catalysis
More informationThe New Coen Micro-NOx
COEN The New THE COST-EFFECTIVE SOLUTION FOR FIRETUBE & INDUSTRIAL BURNER APPLICATIONS FOR TODAY S TOUGH APPLICATIONS THE NEW MICRO-NOX SOLUTION Performance Coen s New Micro-NOx burner is specifically
More informationCIMAC NMA Norway 27 January 2010
CIMAC NMA Norway 27 January 2010 Ole Skeltved Head of the Marine Installation Department Marine Low Speed, Engineering < 1 > System solutions for reduction of exhaust gas emissions Agenda : NOx limitations
More informationUpflow, Upflow / Horizontal, Counterflow / Horizontal
Upflow, Upflow / Horizontal, Counterflow / Horizontal CG80 Features and Benefits HEAT EXCHANGER DESIGN Aluminized steel tapered S-curve design primary exchanger with crimped no weld construction for long
More informationWarm. Air Turnover Systems. Applied Air. Keeps You. Technical Guide for: IFP IFS CAT IFA IFJ TGATS-4. Standard Gas Heat Air Turnover
TGATS-4 Air Turnover Systems Technical Guide for: IFP IFS CAT IFA IFJ Standard Gas Heat Air Turnover Non Gas Heat Slave Unit Standard Cooling Only Air Turnover with Prop Fans Standard Cooling Coil Plus
More informationSteinmüller Engineering GmbH POWER-GEN Europe, Vienna
Steinmüller Engineering GmbH 2013-06-06 POWER-GEN Europe, Vienna Combustion optimisation, efficiency improvements and emission reduction by installation of modern LowNO x firing systems at existing bituminous
More informationG8MVL. Product Specifications
80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in
More informationPower Generation Flexibilisation Case Studies from Germany. By Ronald Rost & Arun Kumar Sarna
Power Generation Flexibilisation Case Studies from Germany By Ronald Rost & Arun Kumar Sarna Agenda About VPC & Encotec Moorburg Flexibilisation flexgen Jaenschwalde 2 VPC GmbH Flexibilisation case studies
More informationDesign Features and Commissioning of the 700 MW Coal-Fired Boiler at the Tsuruga Thermal Power Station No. 2
106 Design Features and Commissioning of the 700 MW Coal-Fired Boiler at the Tsuruga Thermal Power Station No. 2 Susumu Sato *1 Masahiko Matsuda *1 Takao Hashimoto *2 Yoshiyuki Wakabayashi *2 Akira Hashimoto
More informationOLR Product Specifications
OLR Product Specifications LO BOY OIL FURNACE C Illustrations and photographs are only representative. Some product models may vary. US 85.0 to 86.8 ONLY applies to applications in Canada where the furnace
More informationD SERIES BURNERS 4.2 TO 42.0 MMBTU/HR
D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Industrial Combustion offers complete boiler
More informationRDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL
The Riello RDB series of one stage light oil and kerosene burners is available in eleven basic models, with an output ranging from 16,8 to 120 kw, in three different structures. The models are available
More informationECONOMATIC REX/REXF REX/REXF DUAL STR
TECHNICAL MANUAL ECONOMATIC REX/REXF REX/REXF DUAL STR PRESSURISED STEEL BOILERS 96R WALTON ROAD, EAST MOLESEY, SURREY, KT8 0DL Tel. 08707 707 747 Fax. 08707 707 767 info@stokvisboilers.com - www.stokvisboilers.com
More informationSteven J. O Connor Senior Applications Engineer Bloom Engineering Company
Steven J. O Connor Senior Applications Engineer Bloom Engineering Company Burners Evaluated Regenerative Burners Very efficient with high air preheat entering the burner head 80% of the waste gases leave
More informationComplete firing plants with silo, dosing machine, assembly and the commissioning. Reliable customer service. Service and assembly from one hand
HOT GAS GENERATOR COMBUSTION CHAMBERS System Dr. Schoppe for PULVERIZED LIGNITE fuel oil and gas from 100 kw up to 300 MW CARBOTECHNIK Hot gas generator 40 MW for pulverized lignite, fuel oil and sewer
More informationButterfly valves BVG, BVA, BV..F, BVH, BVHR, BVHS, BVHM Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS For gas, air, hot air and
Butterfly valves BVG,, BV..F, BVH, BVHR, BVHS, BVH Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS For gas, air, hot air and flue gas Low leakage rate and pressure loss High control accuracy
More informationPROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.
PROFIRE D Series burners 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Cleaver-Brooks offers complete boiler
More informationHamilton 3VO Submittal
Job RESET FORM Engineer Hamilton 3VO Submittal BOILER s H3H 750 WATER HEATER s H3D 750 Contractor Prepared By Date Input 100% factory fire tested Efficiency: up to 99.8% (based on incoming water) Maximum
More informationProduct Data. that this product meets the S 95% AFUE S Two -stage operation
DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling
More informationStaff Subcommittee on Electricity and Electric Reliability
Staff Subcommittee on Electricity and Electric Reliability Staff Subcommittee on Electricity & Electric Reliability and Staff Subcommittee on Clean Coal & Carbon Management Chinese Clean Coal Technology
More informationCab Heater and Air Conditioner, Pneumatically Controlled 83.01
Cab Heater and Air Conditioner, Pneumatically Controlled.0 Temperature Actuator Replacement. Remove the quick-release screws, then remove the IP fuse junction panel trim See Fig.. 0//9 f4 Fig., Floor Duct
More informationButterfly valves BVG, BVA, BV..F, BVH, BVHR, BVHS, BVHM Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS
Butterfly valves BVG,, BV..F, BVH, BVHR, BVHS, BVH Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS Product brochure GB 3 Edition 03.16 For gas, air, hot air and flue gas Low leakage rate
More informationSGT5-2000E Latest Service Improvements for Optimized Operations, Maintenance and LNG Fuel Conversion Upgrade Grit Hennig
SGT5-2000E Latest Service Improvements for Optimized Operations, Maintenance and LNG Fuel Conversion Upgrade All rights reserved. siemens.com/power-generation-services Siemens Gas Turbines Table of content
More informationproduct Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable
product Information on oil, gas and dual fuel burners Minimale Industrial Emissionswerte burners mit Gas Industrial burners 1, 11,7 kw flexible and reliable Weishaupt Industrial Burners: Flexible and reliable
More informationWET COMPRESSION. What it Is Not. What it Is. Is not traditional inlet air cooling, like a fogger or a chiller
IGTI 2011 June 8 th, 2011 What it Is 8 to 25% (~12% 7EA) Power Augmentation at any wet bulb temperature above 45 F Complimentary Technology -used in series w/ inlet cooling & other GT upgrades Technology
More information5.0 DIESEL HYDROTREATING UNIT
5.0 DIESEL HYDROTREATING UNIT 5.1 INTRODUCTION 5.1.1 PURPOSE The main purpose of the DHDT unit is to hydrotreat the diesel components from atmospheric and vacuum units of existing and expansion units,
More information