REFRIGERATION STRAINERS

Size: px
Start display at page:

Download "REFRIGERATION STRAINERS"

Transcription

1 REFRIGERATION STRAINERS AC & R OIL FILTER - POE OIL FILTER-DRIER S-4004 AC&R Components S-4004 Oil Filter removes foreign material from the oil as it passes through the filter. The filter easily captures any debris that may be in the system, such as dirt, metal chips, etc. (particle retention 10 micron). The S-4004 is required on all Electronic Oil Level Controllers to protect the solenoid manifold. S-4005 The use of polyolester Oil (POE) is required for use with the new HFC refrigerants. However, there are some drawbacks. 1. POE oil is more hygroscopic. It absorbs moisture at a much greater rate than mineral oils. Moisture in any system can produce harmful conditions. 2. POE oil is a potent solvent, capable of cleaning up pipe scale, sludge, and other system contaminants In order to trap these contaminants and moisture, frequent changing of the liquid and suction line filter-driers is recommended. Because the contaminants and moisture can return with the POE oil to the compressor s crankcase, why not clean the oil at its source? AC&R Components, Inc. has developed the POE Oil Filter & Drier for POE oil return on systems using Oil Separators and Oil Control Systems. This is not a refrigerant Filter Drier. It is designed to operate at a very low pressure drop in a 100% oil environment. The New POE Oil Filter & Drier, Catalog No. S-4005, was designed to clean and dry POE oil as it is returned to the compressor crankcase or Oil Reservoir in parallel systems. Clean and dry POE oil assures the proper operation of the float assemblies in the Oil Separator and the Oil Level Regulators. The S-4005 POE Filter Drier features: 1. Extra large filter area: 325 sq. inches, to ensure cleanup of the oil. 2. Filled with 8 cubic inches of XH9 desiccant, the recommended desiccant for high moisture removal from POE oil. 3. High flow capacity with low pressure drop. 4. Same connection size as oil return line from Oil Separator (3/8-in.male flare). 5. UL approved. 6. No need to install multiple strainers to each oil level regulator. 7. Also for use with Alkybenzene and Mineral Oil. 8. Replace after 15 psig pressure drop. HENRY STRAIGHT-THROUGH STRAINERS NON-CLEANABLE Design Features: 1. Steel. 2. Stainless steel screen. 3. Maximum working pressure: 500 PSI (35 KG/CM²). 4. Temperature rating: -20 F (-29 C) to +300 F (+149 C). 5. Suitable for refrigerants and other industrial fluids non-corrosive to steel. PART NO. 891S-1/4 1/4 FLARE S-3/8 3/8 FLARE S-5/8S 5/8 ODS

2 REFRIGERATION STRAINERS HENRY ANGLE, FLANGED CLEANOUT BRASS SHELL & END CAP STRAINERS P383 ANGLE 866 ( ) MONEL REPLACEABLE SCREEN CARTRIDGE REINFORCED WITH 10 MESH BRASS SCREEN. SCREEN CARTRIDGES ARE SECURELY LOCATED BY MEANS OF SPRING TENSION, PREVENTING BY-PASSING OF REFRIGERANT. SCREEN DATA DIMENSIONS SIZE ODS FACE OF INLET CENTER TO CONNECTIONS MESH SIZE AREA LENGTH OVERALL TO CENTER OUTLET (sq. in.) LENGTH OF OUTLET FACE P/N 5/ /2 4-3/4 2-1/16 7-1/ /8 7/ /2 5-1/16 2-3/8 7-3/ /8 1-1/ /2 5-1/16 2-1/2 7-3/ /8 NOTE: *Dimension is the minimum space required to remove the cartridge from the shell. WATTS STRAINERS BRONZE. Y STRAINERS FOR WATER AND STEAM SERVICE. 20 MESH STAINLESS STEEL, OTHER OPTIONS AVAILABLE F, WSP F. 777S THREADED CONNECTIONS. S777S SWEAT CONNECTIONS. TAPED FOR CLOSURE PLUG (CLOSURE PLUG NOT INCLUDED). MAXIMUM PRESSURE RATINGS FOR SWEAT IS F AND REQUIRES 95-5 SOLDER (REF. ANSI B16.18) AND STEAM 15 PSI MAXIMUM. SIZE DIMENSIONS MFG P/N P/N A B C THREADED SWEAT THREADED SWEAT 1/ /8 NPT 1/2 777S 1/2 S777S WAT 1/2 777S WAT 1/2 S777S 3/4 3-5/16 2-5/16 3/4 NPT 3/4 777S 3/4 S777S WAT 3/4 777S WAT 3/4 S777S 1 4-1/2 2-15/16 3/4 NPT 1 777S 1 S777S WAT 1 777S WAT 1 S777S 1-1/4 5-1/8 3- I/8 3/4 NPT 1-1/4 777S 1-1/4 S777S WAT 11/4 777S WAT 11/4 S777S 1-1/2 5-7/8 3-1/4 1 NPT 1-1/2 777S 1-1/2 S777S WAT 11/2 777S WAT 11/2 S777S 2 6-3/16 5-7/8 1-1/4 NPT 2 777S 2 S777S WAT 2 777S WAT 2 S777S /8 6-1/16 1-1/2 NPT 3 777S WAT 3 777S /2 1-1/2 NPT 4 777S WAT 4 777S 740

3 REFRIGERATION STRAINERS PARKER COPPER STRAINERS/STRAINER DISTRIBUTORS Strainers are low cost filtration devices designed to protect refrigeration components, including valves, compressors and capillary tubes, from system contaminants. P4092 Key Features and Benefits Copper construction to resist corrosion. 500 psig design pressure. Available in a variety of inlet and outlet sizes. UL recognized (File SA-8570) and CSA certified (LR-87950). Proper selection of strainers is based on two parameters: 1. Maximum operating pressure 2. Contaminants present in the system. Maximum Operating Pressure Information regarding operating pressure is required to adequately size the wall thickness of the strainer to attain the ultimate burst pressure. In accordance with Underwriters Laboratories (UL) and Canadian Standards Association (CSA), the burst pressure for Parker strainers is rated as five times the design working pressure of the system. Listed in the catalog as design working pressure, this value can be correlated to tube diameter and wall thickness in order to meet specific UL specifications. Contaminants To determine the type and area of the screen, information about contaminants is needed. The size, type and cleanliness of the refrigeration system and its components, as well as the control of the assembly process, all determine the amount and size of the contaminants to be trapped by the strainer. The most common size of screen is 150 x 140 mesh which is used to protect capillary tubes. An extra large screen area should be selected if the strainer is expected to trap large amounts of foreign material. The large screen area will ensure there is enough area for passage of fluid without causing pressure drop. Recommended Screen Area SCREEN AREA (sq in.) LOW TEMP MED. TEMP R-12 & R-134a R-12 & R-134a 0 or Below 0 F or Above Strainer Screen Dimensions LOW TEMP R-22 AIR COND. R /8 hp 1/4 hp 1/8 hp 1/3 hp 1.8 1/4 hp 1/3 hp 1/3 hp 1/2 hp 2.2 1/3 hp 1/2 hp 1/2 hp 3/4 hp 2.3 1/2 hp 3/4 hp 3/4 hp 1 hp /2 hp 2 hp 1-1/2 hp 3 hp 6 2 hp 3 hp 2 hp 5 hp MESH DIAMETER OF WIRE PARTICLE SIZE MAXIMUM DIAMETER SCREEN MICRON MATERIAL SIZE % OPEN AREA 100 x s.s % 120 x brass % 150 x s.s % Strainer Dimensions PART NO. OVERALL LENGTH AREA (sq in.) INLET I.D. OUTLET I.D. SCREEN PS-2S /4 1/4 120 mesh brass PS-3S /8 3/8 120 mesh brass PS-4S /2 1/2 100 mesh stainless steel PS-5S /8 5/8 100 mesh stainless steel PS-7S /8 7/8 100 mesh stainless steel PS-9S /8 1-1/8 100 mesh stainless steel PS-11S /8 1-3/8 100 mesh stainless steel PS-13S /8 1-5/8 40 mesh stainless steel 741

4 REFRIGERATION STRAINERS PARKER COPPER STRAINERS/STRAINER DISTRIBUTORS 5/8 O.D. Copper Strainers Standard Products PART NO. DESIGN WORKING PRESSURE (psig) FILTRATION CAPACITY MICRONS SCREEN AREA (sq in.) INLET I.D. (B) OUTLET I.D. (C) OVERALL LENGTH (A) / /4 O.D. Copper Strainers PART NO. DESIGN WORKING PRESSURE (psig) FILTRATION CAPACITY MICRONS SCREEN AREA (sq in.) INLET I.D. (B) OUTLET I.D. (C) OVERALL LENGTH (A) /4 1/ /8 5/ /8 3/8 OD /8 3/ /2 1/2 OD /2 1/ /8 3/ P4093 P O.D. Copper Strainers Part No. Design Working Pressure (psig) STANDARD PRODUCT Filtration Capacity Microns Screen Area (sq in.) Inlet I.D. (B) Outlet I.D. (C) Overall Length (A) /8 1/ MODIFIED STANDARD see chart below P4095 Outlet Options Outlet No. of Holes Outlet No. of Holes , 2, 3, 4, 5, 6, / / / , 2, 3, 4, 5, 6, 8 3/ /2 1 NOTE: All 1-in. O.D. strainers are Underwriters Laboratories recognized file SA-8570, guide card SMGT-2 and Canadian Standards Association certified file No. LR Model Inlet Options Inlet No. of Holes 3/16 1 1/4 1, 2 5/16 1, 2 3/8 1 1/2 1 5/

5 REFRIGERATION STRAINERS PARKER COPPER STRAINERS/STRAINER DISTRIBUTORS 1-3/16 O.D. Copper Strainers Part No. Design Working Pressure (psig) STANDARD PRODUCT Filtration Capacity Microns Screen Area (sq in.) Inlet I.D. (B) Outlet I.D. (C) Overall Length (A) /2 1/ MODIFIED STANDARD see chart below P4096 Outlet Options Outlet No. of Holes Outlet No. of Holes , 2, 3, 4, 5, 6 1/ , 2, 4 5/ , 3, 4, 6 3/8 1, , 2 1/2 1 NOTE: All 1-3/16-in. O.D. strainers are Underwriters Laboratories recognized file SA-8570, guide card SMGT-2 and Canadian Standard Association certified file No. LR Model 319. Inlet Options Inlet No. of Holes 1/4 1 5/16 1, 2 3/8 1, 2 1/2 1 5/ /8 O.D. Copper Strainers PART NO. DESIGN WORKING PRESSURE (psig) FILTRATION CAPACITY MICRONS SCREEN AREA (sq in.) INLET I.D. (B) OUTLET I.D. (C) OVERALL LENGTH (A) /4 1/ / OD 5.44 NOTE: All 1-5/8-in. O.D. strainers are Underwriters Laboratories recognized file SA-8570, guide card SMGT-2 and Canadian Standard Association certified file No. LR Model P

6 REFRIGERATION STRAINERS A-1 STRAINERS Designed to trap particulates in the refrigerant to protect the system from clogging. Features: Available with 1, 2, 3, and 4 outlets. Inlet dimensions of 1/4 to 3/8. Outlet dimensions of to 3/8. Equipped with S.S. mesh screen. PRODUCT NO. INLET OUTLET NO. OF OUTLETS LENGTH ORDER NO. S-4 1/ / S-6 1/4 1/ / S-8 1/ S-84 1/4 1/ S-842 1/4 1/ S-86 3/8 3/ S-862 3/8 1/ S-132 3/8 1/ S-134 3/8 1/ S-136 3/8 3/ S-152 1/4 1/ S-154 1/4 1/ S-842D 1/ S-862D 3/ S-942D 1/ S-962D 3/ S-942T 1/ S-962T 3/ S-861Q 3/ S-942Q 1/ S-962Q 3/ P

7 PACKLESS VIBRATION ABSORBERS VIBRATION ABSORBERS Sixteen models available to fit copper tubing from 1/4 through 4-1/8 in. O.D. UL and CSA approved. Each unit pressure and vacuum tested, cleaned, dehydrated and sealed in plastic film. P4215 PART NUMBER TO FIT COPPER TUBING HAVING: Actual O.D. Nominal I.D. SHIPPING WEIGHT (lb) *UL and CSA approved for low side (suction side) use only. Flex Tubing I.D. A Tube End Length B DIMENSIONS Flex Tubing Length C Overall Length D Ferrule Length E UL STYLE NUMBER MAX WORKING PRESSURE (psig) BURST PRESSURE (psig) PAC-VAF-1 1/4 1/8 1/4 1/4 1/ /2 P PAC-VAF-2 1/4 1/8 1/4 1/4 1/2 6-1/2 7-1/2 1/2 P PAC-VAF-3 3/8 1/4 3/8 3/8 5/ /4 1/2 P PAC-VAF-4 1/2 3/8 3/8 3/8 3/4 7-1/2 9 1/2 P PAC-VAF-5 5/8 1/2 5/8 1/2 7/ /4 1/2 P PAC-VAF-6 3/4 5/8 5/8 1/ /2 P PAC-VAF-7 3/4 5/8 1-1/4 3/4 1-1/ /4 5/8 P PAC-VAF-8 7/8 3/4 1-1/4 3/4 1-1/ /2 5/8 P PAC-VAF-9 1-1/ / / /16 P PAC-VAF /8 1-1/4 2-1/2 1-1/4 1-5/8 11-1/2 14-3/4 1 P PAC-VAF /8 1-1/2 3-3/4 1-1/ /8 P PAC-VAF / / /2 P PAC-VAF /8 2-1/ / P PAC-VAF / / P PAC-VAF /8 3-1/ / /8 2 P * 525 PAC-VAF / / /8 2 P *

8 HEAD PRESSURE CONTROLS TOTALINE HEAD PRESSURE CONTROLS OPERATION The HeadMaster control is a three-way modulating valve controlled by the discharge pressure. At outdoor temperatures which cause the compressor discharge pressure to be above the head pressure control valve setting, there is no refrigerant flow through the B port of the valve. The flow is through the condenser and valve ports C and R, as shown in FIGURE A. P387 Maintains proper air cooled condenser pressures during periods of low outdoor ambient conditions. Without proper control of condensing pressure, poor refrigeration and component damage can occur. The Totaline HeadMaster control offers an efficient and economical approach to this common industry problem on air cooled condensers. The HeadMaster 3-way head pressure control valve eliminates the need for special piping or multiple control valves. As a single unit it simplifies piping and reduces the installation costs. PRECAUTIONS 1. The HeadMaster control should not be used on a system which does not have a liquid receiver or on one with a receiver which is too small. If the receiver does not have adequate storage space, the refrigerant will back up in the condenser to produce excessively high discharge pressures during high ambient air temperatures. This will cause system damage and/or personal injury. 2. The HeadMaster control should be used only on systems which employ a thermostatic expansion valve. 3. Good refrigeration practice states that the total system charge should not exceed 75% of the receiver capacity. 4. Condenser fans should not be cycled when using the Head- Master control. The sudden changes in high side pressure caused by fan cycling will result in erratic thermostatic expansion valve performance and shortened head pressure control life. FIGURE A As ambient air temperature falls, there will be a corresponding decrease in head pressure. When the discharge pressure fails below the valve setting, discharge gas will flow through the B port into the receiver, creating a higher pressure at the condenser outlet. The higher pressure at the condenser outlet reduces the flow from Port C and causes the level of condensed liquid to rise in the condenser, as shown in FIGURE B. The flooding of the condenser with liquid reduces the available condensing surface. The result is to increase the pressure in the condenser and maintain an adequate high side pressure. P273-2 P273-1 FIGURE B ADDITIONAL REFRIGERANT On most systems, an additional amount of refrigerant will be required. It is essential to have enough to completely fill the condenser for the lowest ambient condition. To accurately determine the amount of additional refrigerant charge required to fill the condenser, find the total length of condenser tubing in feet, and multiply by the number of pounds of refrigerant per foot for a given size tubing. Table #1 shows the liquid refrigerant per foot, per lowest winter temperature to be encountered. TABLE #1 - REFRIGERANT POUNDS PER FOOT* CONDENSER TUBE SIZE - O.D.** REFRIGERANT 3/8 1/2 5/8 AMBIENT TEMPERATURE ( F) R R R *Return bends: 3/8 O.D ft., 1/2 O.D ft., 5/ ft. **Wall thickness:.016-3/8 O.D.,.017-1/2 O.D.,.018-5/8 O.D. 746

9 HEAD PRESSURE CONTROLS HEAD PRESSURE CONTROLS FACTORY SETTING The HeadMaster control is factory set to provide an average condensing temperature consistent with good system performance. The complete type number includes the service reference code, port size, connection size and style, see FIGURE C. For sizing selection see Table #2. When ordering be sure to specify the complete type number. NOTE: Be sure valve is not required to operate at conditions exceeding maximum safe working pressure of 440 PSI. SERVICE REFERENCE CODE REFRIGERANT SERVICE SERVICE CODE CONDENSING TEMP. R-12 A 98 F + 6 deg. R-22 B R-502 B 95 F + 6 deg. FIGURE C CAPACITY AND SELECTION The nominal HeadMaster control capacity in tons is shown in Table #3 for R-12, R-22 and R-502. The nominal capacity is based on 100 F liquid, 40 F evaporator and the pressure drop shown. To obtain capacities in tons at other liquid and evaporator conditions, multiply the nominal capacity at the desired pressure drop by the factor in Table #4 given for the existing liquid temperature and evaporator temperature. TABLE #2 - SIZING SELECTION SERIES NUMBER P520-HP5 P520-HP8 P520-HP14 SIZE & STYLE CONN. REFRIGERANT R-12 R-22 & R-502 P/N 3/8 ODF P520-HP5T3-A P520-HP5T3-B 1/2 ODF P520-HP5T4-A P520-HP5T4-B 1/2 ODF P520-HP8T4-A P520-HP8T4-B 5/8 ODF P520-HP8T5-A P520-HP8T5-B 7/8 ODF P520-HP8T7-A P520-HP8T7-B 7/8 ODF P520-HP14T7-A P520-HP14T7-B 1-1/8 ODF P520-HP14T9-A P520-HP14T9-B 1-3/8 ODF P520-HP14T11-A P520-HP14T11-B Do not select a valve for a capacity rating exceeding 5 psi pressure drop from Port C to Port B or for a system with more than 20 psi pressure drop across the condenser. During normal ambient conditions the available liquid sub-cooling in the condenser shall be adequate to cover the existing pressure drop through the HeadMaster control. If a valve is selected for a given flow rate, the resultant pressure drop must not cause the liquid pressure to drop below saturation and produce flash gas. If sufficient sub-cooling is not available to cover this pressure drop, it is suggested that more than one valve be installed in parallel to reduce the pressure drop to tolerable limits (see FIGURE D). Do not parallel valves of different capacities. Liquid drain lines from the condenser to receiver are generally sized for a velocity of 150 ft./min. P274 FIGURE D TABLE #3 - NOMINAL CAPACITY (TONS)* REFRIGERANT PRESSURE DROP - PSI P/N P520-HP5 R P520-HP P520-HP P520-HP5 R P520-HP P520-HP P520-HP5 R P520-HP P520-HP14 *Based on 100 F liquid and 40 F evaporator.. TABLE #4 - MULTIPLIER FACTORS FOR CAPACITIES AT CONDITIONS OTHER THAN NOMINAL RATINGS LIQUID TEMPERATURE ( F) R-12 R-22 R-502 EVAPORATOR TEMPERATURE

10 PRESSURE REGULATORS TOTALINE CRANKCASE PRESSURE REGULATORS - CPR P525 - PART NUMBER SIGNIFICANCE D = DANFOSS E = IPR/EPR (EVAP) C = OPR/CPR (CC) H = CPCE L = LG (LIQUID MIXER) PORT DIA IN 1/8 06 = 3/4 10 = 1-1/4 CONNECTION SIZE IN 1/8 CONNECTION F = SAE T = ODF/ODM NOMINAL ADJUSTABLE PSIG RANGE A = 0-50 B = C = D = 0-60 E = 0-80 F = 0-85 G = 7-85 H = NON- ADJUSTABLE P388 The CPR crankcase pressure regulator is mounted in the suction line ahead of the compressor. Its purpose is to protect the compressor motor against overload due to high suction pressures during start up after long standstill periods (high temperature in the cold room) and after defrost periods. Type CPR makes it possible to use a small motor on low temperature systems. A smaller motor will, during normal operation, operate with improved efficiency, since the motor size is better suited to the load. At the same time the improved efficiency means that the motor does not overheat. This is important in the case of suction gas cooled hermetic and semi-hermetic compressors. PULSATION DAMPING DESIGN minimizes flow noise; extends regulator life. COMPACT ANGLE DESIGN for ease of installation. HERMETIC, brazed construction design, no synthetic o-rings, or gaskets to wear and leak. APPLICABLE TO R-12, R-22, R-502, and other fluorinated refrigerants. TECHNICAL DATA CPR 12, 15, 22 CPR 28, 35 *Other fluorinated refrigerants, for example R-500, can be used at the stated temperatures and pressures. **P-band = proportional band. Proportional band is the change in pressure required to move valve from full closed to full open position. ORDERING REFRIGERANTS R-12, R-22, R-502* R-12, R-22, R-502* REGULATION RANGE (psig) MAX. TEMPERATURE ( F) MAX. OPERATING PRESSURE (psig) MAX.TEST PRESSURE (psig) P-BAND** (psi) C v FACTOR GAL/MIN AT THE STATED P-BAND** 7 to to NOMINAL CAPACITY TONS* FLARE CONNECTION SOLDER CONNECTION R-12 R-22 R-502 SAE P/N ODF P/N CPR /2 P525-C06F04GD 1/2 P525-C06T04GD CPR /8 P525-C06F05GD 5/8 P525-C06T05GD CPR /8 P525-C06T07GD CPR /8 P525-C10T09GD CPR /8 P525-C10T11GD *Nominal capacity is the regulator capacity at: Evaporating temperature t o = +15 F Condensing temperature t k = +100 F Pressure drop in regulator p = 2 psi P-band for CPR = 20 psi. NOTE: The connections chosen must be too small in diameter since gas velocities in excess of 130 ft./sq. in the connector of the regulator can cause flow noise. 748

11 PRESSURE REGULATORS TOTALINE EVAPORATOR PRESSURE REGULATORS - EPR P525 - PART NUMBER SIGNIFICANCE D = DANFOSS P276 E = IPR/EPR (EVAP) C = OPR/CPR (CC) H = CPCE L = LG (LIQUID MIXER) PORT DIA IN 1/8 06 = 3/4 10 = 1-1/4 CONNECTION SIZE IN 1/8 CONNECTION F = SAE T = ODF/ODM NOMINAL ADJUSTABLE PSIG RANGE A = 0-50 B = C = D = 0-60 E = 0-80 F = 0-85 G = 7-85 H = NON- ADJUSTABLE The EPR evaporating pressure regulator is mounted in the suction line after the evaporator and is used for: 1. Maintaining a constant evaporating pressure and thus a constant evaporator surface temperature. Regulation is modulating. In the event of throttling in the suction line, the extracted quantity of refrigerant gas is matched to the evaporator load. 2. Protection against too low an evaporating pressure for example, as a safeguard against freezing up of a water chiller. The regulator closes when the pressure in the evaporator drops below the set value. Type EPR is highly suitable for these functions since it has a relatively small P-band and regulation accuracy even with large load variations. TECHNICAL DATA The drawing shows a EPR mounted in the suction line on a system having two evaporators. On systems where more than one evaporator is connected to the same compressor the EPR is mounted in the suction line from the evaporator in which the pressure is to be kept higher than the design suction pressure. The regulator will then throttle the suction gas from the required higher evaporating pressure to the design suction pressure. PULSATION DAMPING DESIGN minimizes flow noise; extends regulator life. COMPACT ANGLE DESIGN for ease of installation. HERMETIC, brazed construction design, no synthetic o-rings, or gaskets to wear and leak. APPLICABLE TO R-12, R-22, R-502, and other fluorinated refrigerants. *Other fluorinated refrigerants, for example R-500, can be used at the stated temperatures and pressures. **P-band = proportional band. Proportional band is the change in pressure required to move valve from full closed to full open position. ORDERING REFRIGERANTS REGULATION RANGE (psig) MAX. TEMPERATURE ( F) MAX. OPERATING PRESSURE (psig) MAX.TEST PRESSURE (psig) P-BAND** (psi) C v FACTOR GAL/MIN AT THE STATED P-BAND- EPR 12, 15, 22 R-12, R-22, R-502* 3 to EPR 28, 35 R-12, R-22, R-502* 0 to NOMINAL CAPACITY TONS* SOLDER CONNECTION SAE P/N R-12 R-22 R-502 ODF P/N EPR /2 P525-E06F04ED 1/2 P525-E06T04ED EPR /8 P525-E06F05GD 5/8 P525-E06T05ED EPR /8 P525-E06T07ED EPR /8 P525-E10T09ED EPR /8 P525-E10T11ED *Nominal capacity is the regulator capacity at: Evaporating temperature t o = +15 F Condensing temperature t k = +100 F Pressure drop in regulator p = 3 psi Offset = 8 psi. NOTE: The connections chosen must be too small in diameter since gas velocities in excess of 130 ft./sq. in the connector of the regulator can cause flow noise. 749

12 PRESSURE REGULATORS TOTALINE HOT-GAS BYPASS REGULATORS P525 - PART NUMBER SIGNIFICANCE D = DANFOSS P390 P277 E = IPR/EPR (EVAP) C = OPR/CPR (CC) H = CPCE L = LG (LIQUID MIXER) PORT DIA IN 1/8 06 = 3/4 10 = 1-1/4 CONNECTION SIZE IN 1/8 CONNECTION F = SAE T = ODF/ODM NOMINAL ADJUSTABLE PSIG RANGE A = 0-50 B = C = D = 0-60 E = 0-80 F = 0-85 G = 7-85 H = NON- ADJUSTABLE Hot-gas bypass Regulators are used to adapt compressor capacity to actual evaporator load. Capacity regulation by hot-gas injection at the evaporator inlet has the advantage that the thermostatic expansion valve reacts to the increased superheat of the refrigerant at the evaporator inlet, and injects the extra amount of liquid necessary to remove the superheat. This method avoids the installation of a special injection valve to cool the suction gas. Another advantage is that gas velocity in the evaporator is increased so that oil return is improved. This is especially important when the evaporator is positioned lower than the compressor. Hot-gas bypass regulators are installed in a bypass between the high and low pressure sides of the refrigeration system. When the load on the evaporator and the corresponding load on the compressor falls, the suction pressure of the compressor falls. This opens the regulator to produce a false load (replacement load) on the evaporator, in the form of hot-gas from the high pressure side. Hot-gas bypass regulators are especially suitable for hot-gas injection at the evaporator inlet, between the thermostatic expansion valve and the liquid distributor. Hot-gas bypass regulators are equipped with a control pressure connection for the refrigeration system suction line. In this way, the degree of opening of the regulator is directly determined by the compressor suction pressure, independent of the pressure drop on the evaporator side. Hot-gas bypass regulators are primarily designed for refrigeration systems with one evaporator. TECHNICAL DATA *Other fluorinated refrigerants, for example R-500, can be used at the stated temperatures and pressures. **Control pressure when the regulator begins to open. ORDERING REFRIGERANTS *Nominal capacity is the regulator capacity at: REGULATION RANGE (psig) MAX. TEMPERATURE ( F) Suction temperature t s = +26 F Condensing temperature t k = +100 F After a suction temperature reduction of t s = 6 F. MAX. OPERATING PRESSURE (psig) MAX. TEST PRESSURE (psig) 2, 15, 22 R-12, R-22, R-502* 7 to 85** NOMINAL CAPACITY TONS* FLARE CONNECTION SOLDER CONNECTION R-12 R-22 R-502 SAE P/N ODF P/N /2 P525-H02F04FD /2 P525-H02T04FD /8 P525-H03T05FD /8 P525-H06T07FD 750

13 PRESSURE REGULATORS DANFOSS HOT-GAS BYPASS REGULATORS, CPCE LIQUID-GAS MIXERS, LG DANFOSS HEAT RECOVERY REGULATORS, HEAD PRESSURE REGULATORS, KVR, DIFFERENTIAL PRESSURE VALVES, NRD TECHNICAL DATA A liquid-gas mixer type LG should be used for hot-gas injection. The object of the LG is to create a monogeneous mixture of the hot-gas from the CPCE regulator and the liquid from the thermostatic expansion valve so that the function of the liquid distributor (next in the system) remains unimpaired. REFRIGERANTS REGULATION RANGE (BEGINNING TO OPEN) (psig) OPENING DIFFERENTIAL PRESSURE P PSI BEGINNING COMPLETELY OPEN OPEN MAX. TEMPERATURE ( F) MAX. OPERATING PRESSURE (SWIP) (psig) MAX. TEST PRESSURE (psig) KVR 12, 15, 22 R-12, R-22, R-502* 70 to ** KVR 28, 35 R-12, R-22, R-502* 70 to ** NRD R-12, R-22, R-502* *Other fluorinated refrigerants, for example R-500, can be used at the stated temperatures and pressures. **Provided that the Schraeder valve is removed and the connector is sealed with seal cap and nut otherwise +200 F. ORDERING NOMINAL LIQUID CAPACITY (TONS) NOMINAL HOT-GAS CAPACITY (TONS)* FLARE CONNECTION SOLDER CONNECTION R-12 R-22 R-502 R-12 R-22 R-502 SAE P/N ODF P/N KVR / / KVR / / KVR / KVR / KVR / NRD 1/ *The rated capacity is the regulator capacity at evaporating temperature to = +40 F concerning liquid and 0 F concerning hot-gas, condensing temperature t k = +100 F and pressure drop across the valve p = 3 p. EXPANSION VALVE ODM CONNECTION FOR HOT-GAS ODM LIQUID DISTRIBUTOR ODF P/N LG 12/16 5/8 1/2 5/ LG 12/22 7/8 1/2 7/ LG 16/28 1-1/8 5/8 1-1/ LG 22/35 1-3/8 7/8 1-3/ The liquid-gas mixer type LG can also be used in connection with hot-gas defrosting or with reverse cycle systems. P392 P278 Regulator systems KVR + NRD are used to maintain a constant and sufficiently high condensing and receiver pressure in systems with heat recovery or in refrigeration and air conditioning systems with air-cooled condensers. During winter operation the ambient temperature falls and with it the condensing pressure of the air-cooled condenser falls. KVR-regulation is dependent on the inlet pressure. It begins to throttle when the pressure falls below the pressure setting. Consequently, the condenser is partially filled with liquid, so that the effective condensing surface is reduced. In this way the required condensing pressure is restored. Since the real regulation task during winter operation is to keep the receiver pressure at a suitably high value, KVR is combined with a differential pressure valve type NRD, which is sitted in the bypass line shown. NRD begins to open at a differential pressure of 20 psi. When the condensing pressure falls, KVR will begin to throttle. This increases the total pressure drop across the condenser + KVR. When this pressure drop reaches 20 psi, NRD will begin to open thus ensuring that the receiver pressure is maintained. As a rule of thumb, it can be assumed that the pressure in the receiver is equal to the set pressure of the KVR less 14 psi. During summer operation, when the KVR is fully open, the total pressure drop across the condenser and KVR is less than 20 psi. The NRD is therefore closed. To avoid inadvertent opening of the NRD the pressure drop across the condenser at max. load must not exceed 10 psi. If this pressure is exceeded, two NRD units can be used in series instead of one. During summer operation the charge can accumulate in the receiver. Therefore the system must be equipped with a sufficiently large receiver to store the excess refrigerant. 751

14 PRESSURE REGULATORS ALCO EPRB(S) BRASS BODY UPSTREAM REGULATOR This Evaporator Pressure Regulator is a new lightweight, energy-efficient pilot operated regulator. It is supplied with copper connections to allow easy installation into the system. The pilot operation is dependent upon high side system pressure which minimizes the pressure drop across the regulator. This regulator is of normally-open construction so that a manual operator is not required for system evacuation. A solenoid version having the suction stop is available as an option. ALCO EPRB(S) series regulators are pilot operated and designed to maintain a predetermined minimum inlet pressure. They are available in a S version for gas defrost applications. For information on other refrigerant applications please contact ALCO s Applications Engineering Department. FEATURES Energy efficient as it uses high side pressure for pilot operation, which minimizes system pressure drop. 25 lb. system pressure differential needed for valve operation. Uses copper line connections allowing installation with phos-copper alloy, i.e.: no flux. Can be installed without disassembly. Has a wide adjustment range (0-110 psig). Pilot connection available in 1/4-in. SAE or ODF. Easily disassembled to allow easy serviceability. Available with suction stop feature using a take-apart solenoid for additional serviceability. May be installed in either a vertical or horizontal refrigeration line. Pressure tap on inlet connection. External leak tested to less than 1/10 oz. a year. Corrosion resistant to 1000 hour salt spray. Reduced discharge to suction bleed. SPECIFICATIONS Maximum Working Pressure: 450 psig (3100 KPa). MOPD: 350 psi (2412 KPa) S version. Maximum Temperature: 250 F (121 C). S version for use with DMG, AMG or AMC coils only. EPRB(S) EXPLODED VIEW pg592b EPRB(S) REPLACEMENT PARTS When 1/4 ODF pilot repair kits are needed, the following repair kits should be ordered: EPRB Pilot Assembly KR50071 EPRB(S) Pilot Assembly KR ODF PILOT ONLY VALVE SIZE EPRB UPPER EPRB(S) UPPER SUB-ASSEMBLY SUB-ASSEMBLY 12 KR KR KR KR KR KR SAE & ODF SOLENOID ONLY GASKETS KR KR NOTE: Both the Bell/Piston Assembly and the Upper Subassembly Kits contain the main body gasket and spring. SAE PILOT ONLY VALVE SIZE BELL/ PISTON EPRB UPPER SUBASSEMBLY EPRBS UPPER SUBASSEMBLY 12 KR50045 KR50048 KR KR50046 KR50049 KR KR50047 KR50050 KR50056 PILOT ASSEMBLY SAE ONLY EPRB EPRB(S) KR KR

15 PRESSURE REGULATORS ALCO EPRB(S) BRASS BODY UPSTREAM REGULATOR EPRB(S) DIMENSIONAL DATA VALVE A B EPRBS 12 T 9 SAE PILOT 1-1/8 ODF VLC EPRBS 12 T 9 6-7/8 8-1/2 ODF PILOT 1-1/8 ODF VLC EPRBS 16 T 11 ODFPILOT 1-3/8 ODF VLC EPRBS 16 T /2 11-1/16 SAE PILOT 1-3/8 ODF VLC EPRBS 20 T 13 SAE PILOT 1-5/8 ODF VLC EPRBS 20 T /4 12-3/8 ODF PILOT 1-5/8 ODF VLC pg593 UL file number MP604 NOMENCLATURE Guide number Y10Z EPRB S 12 T 9 Valve Suction Stop Port Size Connection Style Connection Size Series (optional) (in 1/16 ) T = ODF (in 1/8 ) example Above: EPRBS 12T9 EPRB(A) EXTENDED CAPACITY TABLES EVAPORATOR TEMP. R-134a + 45 F + 35 F + 25 F + 20 F PRESSURE DROP ACROSS VALVE PSI VALVE EPRBS 12T EPRBS 16T EPRBS 20T EVAPORATOR TEMP. R-134a + 15 F + 10 F + 5 F + 0 F PRESSURE DROP ACROSS VALVE PSI VALVE EPRBS 12T EPRBS 16T EPRBS 20T EVAPORATOR TEMP. R F + 35 F + 20 F +10 F PRESSURE DROP ACROSS VALVE PSI VALVE EPRBS 12T EPRBS 16T EPRBS 20T EVAPORATOR TEMP. R F - 10 F - 20 F - 30 F PRESSURE DROP ACROSS VALVE PSI VALVE EPRBS 12T EPRBS 16T EPRBS 20T

16 PRESSURE REGULATORS ALCO EPRB(S) BRASS BODY UPSTREAM REGULATOR R404A/ R507 EPRB(A) EXTENDED CAPACITY TABLES EVAPORATOR TEMP F + 35 F + 20 F + 10 F PRESSURE DROP ACROSS VALVE PSI VALVE EPRBS 12T EPRBS 16T EPRBS 20T R404A/ R507 EVAPORATOR TEMP. + 0 F - 10 F - 20 F - 30 F PRESSURE DROP ACROSS VALVE PSI VALVE EPRBS 12T EPRBS 16T EPRBS 20T

17 PRESSURE REGULATORS ALCO ESR ELECTRONIC STEPPER REGULATOR The ESR is a direct driven suction regulator that uses a linear actuating bi-polar stepper motor to move the piston. The stepper motor is actuated by a voltage pulse to energize each of the motor phases and move the piston in discrete.001 inch increments. In individual cases, the ESR, along with appropriate control electronics, provides state-of-the-art temperature control within less that ± 1 F of the desired setpoint temperature. The ESR is compatible with many control electronics widely available in the market today. Applications for the ESR include case control, line-up and rack mounted control, as well as transportation applications on refrigerated trucks, trailers and containers. FEATURES No external sealing o-rings. Connections - 7/8 ODF (ESR 12) - 1-3/8 ODF (ESR 20) Removable external connector. Excellent repeatability. Corrosion resistant design. Solenoid tight shut-off. SPECIFICATIONS Operating temperatures: - Ambient: -40 F to 150 F - Refrigerant: -40 F to 140 F Maximum working pressure: 500 psi Linear actuating bi-polar stepper motor Direct drive with no hysteresis Two motors available Step rate: 50 ± 10 steps per second - 12 VDC - 24 VDC Steps full travel: steps (ESR 12) steps (ESR 20) of rated voltage Voltage tolerance: +10% and -15%.001 inch of linear travel per step Resistance (each phase): 29 ohms ± 10% (12 V) or 116 ohms ± 10% (24 V) NOMENCLATURE ESR T 7/11 12/24 V NC ELECTRIC POINT DIAMETER CONNECTION CONNECTION SIZE 12 VOLT/ NO EXTERNAL STEPPER IN 1/16 INCREMENTS T = ODF IN 1/8 INCREMENTS 24 VOLT CONNECTOR REGULATOR ESR-12 = 3/4 DIA. 7 = 7/8 BIPOLAR STEPPER ESR-20 = 1 1/4 DIA. 11 = 1 3/8 MOTOR ESR DIMENSIONAL DATA ESR 12 pg595e pg595b MTB-1 HAND-HELD STEPPER DRIVER Alco Controls provides a hand-held stepper driver to allow the user to verify the Alco ESR (or ESV) responds properly to known driver commands. Compact and easy to use, the MTB-1 and a common multi-meter are the only tools required to completely troubleshoot any Alco electronically driven product. ESR 20 pg595c 755

18 PRESSURE REGULATORS ALCO ESR ELECTRONIC STEPPER REGULATOR ESR EXTENDED CAPACITIES IN TONS R-22 EVAPORATOR TEMPERATURE ESR ESR ESR ESR ESR ESR ESR ESR R-404A/507 EVAPORATOR TEMPERATURE ESR ESR ESR ESR ESR ESR ESR ESR

19 PRESSURE REGULATORS ALCO ESR ELECTRONIC STEPPER REGULATOR ESR EXTENDED CAPACITIES IN TONS R-134a EVAPORATOR TEMPERATURE ESR ESR ESR ESR ESR ESR ORDERING INFORMATION FOR ESR DESCRIPTION ESR 12 T 7 12V NC ESR 12 T 7 24V NC ESR 20 T 11 12V NC ESR 20 T 11 24V NC ESR EXTERNAL MOLDED CONNECTOR 5 ESR EXTERNAL MOLDED CONNECTOR 22 MTB-1 HAND HELD CONTROLLER 757

20 PRESSURE REGULATORS PARKER PRESSURE REGULATING VALVES Features For R-22, R-502, R-404A, R-507 and other common refrigerants Pilot operated for close control at desired set point. Long life diaphragms. No bellows to fail. Lightweight and compact for easy handling. Sweat-in-place without disassembly for fast installation. In-line disassembly for fast service. Available with pilot electric shut-off or pilot electric wide opening. Excellent regulation at light load. Parabolic plug for precise regulation at reduced capacities. A8 Series Features Available for inlet, outlet or differential pressure control function. Dual set spring for smooth response from 10 hg to 400 psi. Low pressure drop 1-1/2 psi at rated capacity allows maximum compressor efficiency, saves energy. One valve handles high side or low side pressure control, reduces inventory. Controlled pressure remains constant within 1-1/2 psi of set point regardless of load fluctuations. Manual bypass opens regulator for quick pumpdown and ease in setting TXV superheat during startup. Furnished with access fitting for monitoring upstream system pressure. All servicing can be done with valve in line; A8 s required only top access. Interchangeable capacity cartridges for all A8 s. Stable drain control down to 20% of rated capacity when properly sized. Parker Type A8A 5/8-1-1/8 ODS Connections P4130 Parker Type A81S 1-1/8-2-1/8 ODS Connections P4131 A9 Series Features External or internal equalizer available. A9 for outlet control function; high pressure difference applications. P4132 Parker Type A82 1-5/8-2-5/8 ODS Connections Selection Guide REGULATOR FUNCTION APPLICATION A8A/A81/A82 Control inlet pressure Evaporator pressure regulator Discharge pressure regulator Liquid drain regulator A8AS/A81S/A82S Control inlet pressure with electric shutoff (defrost) Evaporator pressure regulator A8AB/A81B/A82B Control inlet pressure with wide opening (bypass) Evaporator pressure regulator Discharge pressure regulator A8AL/A81L/A82L Control differential pressure Discharge pressure regulator Liquid supply regulator Oil pressure regulator A8ABL/A81BL/A82BL Control differential pressure with wide opening (bypass) Discharge pressure regulator Liquid supply regulator 758

21 PRESSURE REGULATORS PARKER PRESSURE REGULATING VALVES P4133 Parker Type A81OE 1-1/8-2-1/8 ODS Connections P4134 Parker Type A9E Externally Equalized 5/8, 7/8 and 1-1/8 ODS Connections P4135 Parker Type A9SE Externally Equalized with Pilot Solenoid 5/8, 7/8 and 1-1/8 ODS Connections Condenser Pressure Regulating Applications Fig. 1 Liquid Drain Control Method Fig. 2 Discharge Gas Control Method NOTES: All capacities are in terms of cooling effect at evaporator, not heat rejected at condenser - CANNOT READ REST of manuscript page. Sizing Guide for Condenser Applications Size valve by effective port size. For Liquid Drain Regulator Applications (Fig. 1) Conditions: 3 psi Pressure Drop Type Effective U.S. Capacity in Tons Port R-12 R-22 R-502 A8A 5/8 Reduced A8A 5/8 Full A8A 7/ A81 7/ A81 1-1/ A81 1-3/ A82 1-5/ A82 2-1/ A82 2-5/ For Discharge Regulator Applications (Fig. 2) Conditions: 5 psi Pressure Drop Type Effective U.S. Capacity in Tons Port R-12 R-22 R-502 A8A 5/8 Reduced A8A 5/8 Full A8A 7/ A81 7/ A81 1-1/ A81 1-3/ A82 1-5/ A82 2-1/ A82 2-5/ For Conductor Bypass Regulator Applications (Fig. 1 and 2) Conditions: 0 F Ambient 10 psi Pressure Drop Type Effective U.S. Capacity in Tons Port R-12 R-22 R-502 A9 5/8 Reduced A9 5/8 Full A9 7/ A9 1-1/ For Alternate Condenser Bypass Regulator (Range A Only) Applications (Fig. 1 and 2) Conditions: 0 F Ambient 10 psi Pressure Drop Type Effective U.S. Capacity in Tons Port R-12 R-22 R-502 A8AL 5/8 Reduced A8AL 5/8 Full A8AL 7/ A81L 7/ A81L 1-1/ A81L 1-3/ A82L 1-5/ A82L 2-1/ A82L 2-5/

22 EVAPORATOR PRESSURE REGULATORS PARKER (S)PORT, (S)PORT II Ports 9 mm (3/8 ) to 35 mm (2-1/8 ) Nominal Features Pilot operated for close control at desired set point. Excellent regulation at light loads. Interchangeable capacity cartridges. Low pressure drop. Few moving parts. Long-life stainless steel diaphragms (no bellows to fail). Variations available for pilot electric shutoff and shutoff with electric wide-opening (bypass). Manual opening feature (except (S)PORT-B version). All service from the top. Sweat-in-place without disassembly. Furnished with access fitting. UL listed (except 50 hertz versions). Full open operates at less than 1 psig. Specifications Design pressure (M.R.P.): 31.0 bar (450 psig). Range: 250 mm hg to 8.3 bar (10 hg to 120 psig). Connections: 7/8, 1-1/8, 1-3/8, 1-5/8, 2-1/8, 2-5/8. (S)PORT-7-9 P

23 EVAPORATOR PRESSURE REGULATORS PARKER (S)PORT, (S)PORT II Parker Inlet Pressure Tap or Fitting Port Size in eights (ex: 7 = 7/8 ) S P OR T B 7 11 Electric Shut-Off Open on Rise of Inlet Pressure Bypass Feature or Wide Opening Connection Size in eights (ex: 11 = 1-3/8 ODS Available Port Sizes: 3/8, 5/8, 7/8, 1-1/8,. 1-3/8, 1-5/8, 2-1/8, 2-5/8 Available Connection Sizes: 7/8, 1-1/8, 1-3/8, 1-5/8, 2-1/8, 2-5/8 Selection Procedure This brochure has been developed for easy sizing and selection of the (S)PORT valve. Valve operation and parts information is available in the (S)PORT product Bulletin Selecting the proper port size EPR valve is relatively easy when using the capacity tables. Certain basic information must be known and some specific steps should be followed to ensure accurate port size selection. The following guidelines have been provided to help make the selection process simple. Coil Voltages: (24/60 24/50) (120/60 110/50) (240/60 220/50) (480/60 440/50) Specific operating conditions need to be known: 1. What is the refrigerant being used? 2. What is the medium flowing through the valve? (Suction vapor, hot gas, sub-cooled liquid, etc.). 3. How much is flowing through the valve? (Tons, btu/hr, MBH). 4. What is the valve inlet pressure or temperature? 5. What is the valve outlet pressure or temperature? 6. What is the liquid temperature to the evaporator? Once the preceding information is known, a selection from the capacity table can be made. (S)PORT Selection Table R-404A Low Temperature Effective Port Size (Port size designation in model #) Compr. Rack Case Evap Suction Temp ( F) Temp ( F) /8 (3) 5/8 (5) NOTE: Capacities are based on 100 F liquid, saturated evaporator and 10 F superheat at valve inlet (per ARI ). For each 10 F liquid is below 100 F, INCREASE capacity values by 6%. 7/8 (7) 1-1/8 (9) Valve Capacities MBH /8 (11) 1-5/8 (13) 2-1/8 (17) 761

24 EVAPORATOR PRESSURE REGULATORS DANFOSS EVAPORATOR PRESSURE REGULATORS INTRODUCTION KVP evaporator pressure regulators are mounted in the suction line of refrigeration and air conditioning systems. They are used to maintain a constant pressure corresponding to a constant temperature on the evaporator. They also protect against too low an evaporating pressure by throttling down when pressure falls below the set value. They are also used to differentiate the evaporating pressures in two or more evaporators in systems with one compressor. FEATURES Accurate, adjustable pressure regulation. Wide capacity and operating range. Pulsation damping design. Stainless steel bellows. Compact angle design for easy installation in any position. Hermetic" brazed construction. 1/4 in. Schrader valve for pressure testing. Available with flare and ODF solder connections. For use with CFC, HCFC and HFC refrigerants. APPROVALS UL listed, file SA7200. CSA approved. P4311 TECHNICAL DATA Refrigerants: CFC, HCFC, HFC Regulation range: 0 to 80 psig Factory setting = 29 psig Maximum working pressure: MWP = 200 psig Maximum test pressure: KVP 12 to 22: p = 410 psig KVP 28 to 35: p = 370 psig Maximum temperature of medium: 212 F* Minimum temperature of medium: 40 F* P band (full valve stroke): KVP 12 to 22 = 26 psi KVP 28 to 35 = 40 psi *If the Schrader valve cone is removed and the connector is sealed with cap and nut, the maximum temperature is 300 F and the minimum temperature is 330 F. P4311A 762

25 EVAPORATOR PRESSURE REGULATORS DANFOSS EVAPORATOR PRESSURE REGULATORS ORDERING RATED CAPACITY* (Tons) FLARE CONNECTION SOLDER CONNECTION R-22 R-134a R-404A/R-507 R-407C in. Code No in. ODF Code No. KVP /2 034L0021 1/2 034L0023 KVP /8 034L0022 5/8 034L0029 KVP /8 034L0025 KVP /8 034L0026 KVP /8 034L0032 *Rated capacity is based on: Evaporating temperature t e = 40 F Condensing temperature t c = 100 F Pressure drop across regulator p = 2 psi Offset (design evaporating pressure minus minimum allowable evaporator pressure) = 9 psi. KVP supplied without flare nuts. Separate flare nuts can be supplied: 1/2 in., code no. 011L1103 5/8 in., code no. 011L1167 NOTE: The connection dimensions chosen must not be too small, as gas velocities in excess of 130 ft/s at the inlet of the regulator can result in flow noise. CAPACITY Maximum Regulator Capacity Q e * R-22 PRESSURE DROP CAPACITY Q e IN TONS AT EVAPORATING TEMPERATURE t e F ACROSS REGULATOR p psi KVP KVP KVP KVP KVP Maximum Regulator Capacity Q e * PRESSURE DROP CAPACITY Q e IN TONS AT EVAPORATING TEMPERATURE t e F ACROSS REGULATOR p psi KVP KVP KVP KVP KVP *The capacities are based on: Liquid temperature ahead of expansion valve t l = 100 F Regulator offset p = 9 psi R-134a 763

26 EVAPORATOR PRESSURE REGULATORS DANFOSS EVAPORATOR PRESSURE REGULATORS CAPACITY (cont) Maximum Regulator Capacity Q e * R-404A and R-507 PRESSURE DROP ACROSS REGULATOR CAPACITY Q e IN TONS AT EVAPORATING TEMPERATURE t e F p psi KVP KVP KVP KVP KVP Maximum Regulator Capacity Q e * * The capacities are based on: Liquid temperature ahead of expansion valve t l = 100 F Regulator offset p = 9 psi R-407C PRESSURE DROP ACROSS REGULATOR CAPACITY Q e IN TONS AT EVAPORATING TEMPERATURE t e F p psi KVP KVP KVP KVP KVP Correction factors for liquid temperature t l t l F R R-134a R-404A/R R-407C Correction factors for offset OFFSET PSI KVP 12 KVP KVP 22 KVP KVP

27 EVAPORATOR PRESSURE REGULATORS DANFOSS EVAPORATOR PRESSURE REGULATORS Dimensions and Weights P4311B CONNECTION NV 1 NV 2 H 1 H 2 H 3 B 1 B 2 C DIA. D WEIGHT Flare Solder ODF (lbs) KVP 12 1/2 1/ KVP 15 5/8 5/ KVP 22 7/ KVP / KVP /

28 CONDENSER PRESSURE REGULATORS DANFOSS CONDENSER PRESSURE REGULATORS INTRODUCTION KVR condenser regulators can be mounted in either the gas or liquid side of the condenser in refrigeration and air conditioning systems. They are used to maintain a constant and sufficiently high condensing pressure with systems using air-cooled condensers. They can also be used with valve types NRD or KVD to assure that adequate pressure is maintained on the receiver. FEATURES Accurate, adjustable pressure regulation Wide capacity and operating range Pulsation damping design Stainless steel bellows Compact angle design for easy installation in any position "Hermetic" brazed construction 1/4-in. Schrader valve for pressure testing Available with flare and ODF solder connections For use with CFC, HCFC and HFC refrigerants Can be used as a relief valve from high pressure to suction side P4312 APPROVALS UL listed, file SA7200. CSA approved. TECHNICAL DATA Refrigerants: CFC, HCFC, HFC Regulation range: 70 to 250 psig Factory setting = 145 psig Maximum working pressure: KVR: MWP = 400 psig NRD: MWP = 400 psig Maximum test pressure: KVR: p' = 450 psig NRD: p' = 530 psig Maximum temperature of medium: KVR: 212 F* NRD: 275 F Minimum temperature of medium: 40 F P band (full valve stroke): KVR 12 to 22: 90 psi KVR 28 to 35: 72.5 psi Opening differential pressure for NRD: Fully open: p = 43 psi *If the Schrader valve cone is removed and the connector is sealed with cap and nut, the maximum temperature is 265 F. P4312A 766

29 CONDENSER PRESSURE REGULATORS DANFOSS CONDENSER PRESSURE REGULATORS CAPACITY Maximum regulator capacity Q e * CONDENSING TEMPERATURE t c ( F) *The capacities are based on: Evaporating temperature t e = 40 F For other evaporating temperatures, see correction table. LIQUID CAPACITY IN TONS (Evaporator Capacity) Offset 45 psi Pressure Drop psi HOT GAS CAPACITY IN TONS (Evaporator Capacity) Offset 45 psi Pressure Drop p psi R-22 R-22 KVR KVR KVR KVR KVR Maximum regulator capacity Q e * CONDENSING TEMPERATURE t c ( F) LIQUID CAPACITY IN TONS (Evaporator Capacity) HOT GAS CAPACITY IN TONS (Evaporator Capacity) Offset 45 psi Offset 45 psi Pressure Drop psi Pressure Drop p psi R-134a Correction Factors (Evaporating Temperature) t e F R R-134a R-404A R-407C R System capacity x correction factor = table capacity. R-134a KVR KVR KVR KVR KVR R-404A/R-507 R-404A/R-507 KVR KVR KVR KVR KVR R-407C R-407C KVR KVR KVR KVR KVR

30 CONDENSER PRESSURE REGULATORS DANFOSS CONDENSER PRESSURE REGULATORS DIMENSIONS AND WEIGHTS P4312B CONNECTIONS NV 1 NV 2 H 1 H 2 H 3 L L 1 B 1 B 2 C DIA. D WEIGHT Flare Solder ODF (lbs) KVR 12 1/2 1/ KVR 15 5/8 5/ KVR 22 7/ KVR / KVR / NRD 1/

31 HOT GAS BYPASS CAPACITY REGULATORS DANFOSS HOT GAS BYPASS CAPACITY REGULATORS INTRODUCTION KVC capacity regulators are used to adapt compressor capacity to actual evaporator load by supplying a replacement capacity in form of hot/cool gas. It is installed in a bypass line between the high and low pressure sides of the refrigeration system and is designed for direct gas injection into the suction line. FEATURES Accurate, adjustable pressure regulation. Wide capacity and operating range. Pulsation, damping design. Stainless steel bellows. Compact angle design for easy installation. Hermetic brazed construction. Available with flare and ODF solder connections. For CFC, HCFC and HFC refrigerants. P4313 APPROVALS UL listed, file SA7200. CSA approved. TECHNICAL DATA Refrigerants: CFC, HCFC, HFC Regulation range: 3 to 85 psig Factory setting = 29 psig Maximum working pressure: MWP = 400 psig Maximum test pressure: p' = 450 psig Maximum temperature of medium: 300 F Minimum temperature of medium: 40 F Maximum P-band: 29 psi P4313A ORDERING RATED CAPACITY* (Tons) FLARE CONNECTION SOLDER CONNECTION R-22 R-134a R-404A/R-507 R-407C in. Code No. in. ODF Code No. KVC /2 034L0141 1/2 034L0143 KVC /8 034L0142 5/8 034L0147 KVC /8 034L0144 *Rated capacity is based on: Suction gas temperature t s = 10 F Liquid temperature t l = 100 F Offset p = 10 psi KVC are delivered without flare nuts. Separate flare nuts can be supplied: 1/2 in. code no. 011L1103; 5/8 in. code no. 011L1167. NOTE: The connection dimensions chosen must not be too small, as gas velocities in excess of 130 ft/s at the inlet of the regulator can result in flow noise. If the temperature in the discharge gas line is too high according to the compressor specifications, it is recommended to install a liquid injection valve in a bypass from the liquid line to the suction line. P4313B 769

32 HOT GAS BYPASS CAPACITY REGULATORS DANFOSS HOT GAS BYPASS CAPACITY REGULATORS REPLACEMENT CAPACITY Maximum Regulator Capacity Q e * OFFSET REGULATOR CAPACITY Q TONS SUCTION GAS TEMPERATURE t s AFTER PRESSURE/TEMPERATURE REDUCTION F p psi R-22 KVC KVC KVC R-134a KVC KVC KVC *The capacities are based on: Liquid temperature ahead of the expansion valve t l = 100 F. Correction factors for liquid temperature t l When liquid temperature t l ahead of the evaporator is other than 100 F, adjust the table capacities by multiplying them by the appropriate correction factor found in the following table. t l F R R-134a System capacity x correction factor = table capacity. 770

33 HOT GAS BYPASS CAPACITY REGULATORS DANFOSS HOT GAS BYPASS REGULATORS REPLACEMENT CAPACITY Maximum Regulator Capacity Q e * OFFSET p psi *The capacities are based on: Liquid temperature ahead of the expansion valve t l = 100 F. Correction factors for liquid temperature t l When liquid temperature t l ahead of the evaporator is other than 100 F, adjust the table capacities by multiplying them by the appropriate correction factor found in the following table. REGULATOR CAPACITY Q TONS SUCTION GAS TEMPERATURE t s AFTER PRESSURE/TEMPERATURE REDUCTION F R-404A/R-507 KVC KVC KVC R-407C KVC KVC KVC t l F R-404A/R R-407C System capacity x correction factor = table capacity. SIZING For optimum performance, it is important to select a KVC valve according to system conditions and application. The following data must be used when sizing a KVC valve: Refrigerant: CFC, HCFC or HFC. Suction temperature at maximum compressor/evaporator load t s in F/psig. Minimum suction temperature t s in F/psig. Compressor capacity in tons. Evaporating load in tons. Liquid temperature ahead of expansion valve t l in F. Connection type flare or solder. Connection size in inches. 771

34 CRANKCASE PRESSURE REGULATORS DANFOSS CRANKCASE PRESSURE REGULATORS INTRODUCTION KVL crankcase pressure regulators are used to protect the compressor motor against overload experienced during startup after long off periods or just after defrost periods. They are installed in the suction line of refrigeration systems. FEATURES Accurate, adjustable pressure regulation. Wide capacity and operating range. Pulsation damping design. Stainless steel bellows. Compact angle design for easy installation in any position. Hermetic brazed construction. Available with flare and ODF solder connections. For use with CFC, HCFC and HFC refrigerants. P4314 APPROVALS UL listed, file SA7200. CSA approved. TECHNICAL DATA Refrigerants: CFC, HCFC, HFC Regulation range: 3 to 85 psig Factory setting = 29 psig Maximum working pressure: KVL 12 to 22: MWP = 200 psig KVL 28 to 35: MWP = 200 psig Maximum test pressure: KVL 12 to 22: p' = 405 psig KVL 28 to 35: p' = 370 psig Maximum temperature of medium: 300 F Minimum temperature of medium: 325 F Maximum P-band: KVL 12 to 22: 29 psi KVL 28 to 35: 22 psi P4314A 772

EVAPORATOR PRESSURE REGULATORS

EVAPORATOR PRESSURE REGULATORS PARKER (S)PORT, (S)PORT II FEATURES AND BENEFITS Highest capacity commercial regulator in the industry. Sweat-in-place without disassembly. Interchangeable capacity cartridges. Low pressure drop. Manual

More information

611H Flo-Con Pressure Regulators & Valves

611H Flo-Con Pressure Regulators & Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding 611H Flo-Con Regulators & Valves Catalog F-2, February 2012 Page 2

More information

Condensed Catalog 410A January 2008

Condensed Catalog 410A January 2008 CATALOG Page 1 Condensed Catalog January 2008 This condensed catalog contains product specifically for R- applications. By including a minimum of engineering information we are able to provide a concise

More information

t EVAPORATOR PRESSURE REGULATING VALVES

t EVAPORATOR PRESSURE REGULATING VALVES CATALOG 201 Page 63 t EVAPORATOR PRESSURE REGULATING VALVES (S)ORIT-12, -15 and -20 Features n High side pilot for improved temperature control and low P operation n Adjustable n Optional solenoid stop

More information

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory) MAKING MODERN LIVING POSSIBLE Data sheet Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory) A CPCE hot gas bypass regulator is used to adapt compressor capacity to actual evaporator

More information

Crankcase pressure regulator Type KVL

Crankcase pressure regulator Type KVL MAKING MODERN LIVING POSSIBLE Data sheet Crankcase pressure regulator KVL Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. KVL protects the compressor motor

More information

Crankcase pressure regulator Type KVL

Crankcase pressure regulator Type KVL Data sheet Crankcase KVL KVL crankcase are used to protect the compressor motor against overload experienced during startup after long off periods or just after defrost periods. They are installed in the

More information

Crankcase pressure regulator Type KVL

Crankcase pressure regulator Type KVL Data sheet Crankcase pressure regulator KVL Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. KVL protects the compressor motor against overload during start-up

More information

R-22 R-404A/R-502/R-507A R-12/

R-22 R-404A/R-502/R-507A R-12/ EMERSON CLIMATE TECHNOLOGIES-System Protectors Recommended System Tonnage Take-Apart Liquid Line Filter Driers in Tons* Description, Low Temp. & Commercial Installations Air Conditioning Field Replacement

More information

REFRIGERANT RECOVERY PRODUCTS

REFRIGERANT RECOVERY PRODUCTS REFRIGERANT RECOVERY PRODUCTS PARKER REFRIGERANT RECOVERY PRODUCT Parker provides a large selection of components for recovery, recycle and reclaim machines, protecting them from the many types of contaminants

More information

(S)PORT - (S)PORT-II Evaporator Pressure Regulators

(S)PORT - (S)PORT-II Evaporator Pressure Regulators (S)PORT - (S)PORT-II Evaporator Pressure Regulators Features Highest capacity commercial regulator in the industry Sweat-in-place without disassembly Interchangeable capacity cartridges Low Pressure Drop

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

WEIGHT (lb) PART NO WITH ACCESS CONNECTION (ODS) BALL PORT DIAMETER WA WAS

WEIGHT (lb) PART NO WITH ACCESS CONNECTION (ODS) BALL PORT DIAMETER WA WAS SUPERIOR - BALL VALVES WA SERIES (WELDED) WAS Series (Welded with Access Fittings) Full Service Temperature Range of -40 F to +325 F. Forged Brass Body and Seal Cap. Design Working Pressure: 700 psig.

More information

Parker TEV Model Visual

Parker TEV Model Visual PARKER - THERMOSTATIC EXPANSION VALVES TXV MODEL NUMBER SELECTION Parker TEV Model Visual N Series TEV C(E) Series TEV SC(E) Series TEV Applications: Applications: Applications: Low Profile Coolers, Rail

More information

Subcritical CO 2 Innovations

Subcritical CO 2 Innovations March 2011 / CATALOG 744 Subcritical CO 2 Innovations Energy Conscious Products & Solutions for Supermarkets Subcritical CO 2 Innovations Energy Conscious Products & Solutions for Supermarkets CATALOG

More information

Crankcase Pressure Regulating Valves

Crankcase Pressure Regulating Valves Crankcase Regulating Valves Crankcase Regulating Valves are designed to prevent overloading of the compressor motor by limiting the crankcase pressure to a predetermined maximum value during and after

More information

Steel Suction Line Accumulators

Steel Suction Line Accumulators "U" Tube Style Accumulators The Parker U tube accumulator design is a result of extensive laboratory testing plus detailed investigation of the various accumulators currently available. It takes into account

More information

TAKE-A-PART SHELLS TOTALINE LIQUID & SUCTION LINE REPLACEABLE SHELLS P505-8 SERIES PART NUMBER SIGNIFICANCE

TAKE-A-PART SHELLS TOTALINE LIQUID & SUCTION LINE REPLACEABLE SHELLS P505-8 SERIES PART NUMBER SIGNIFICANCE TOTALINE LIQUID & SUCTION LINE REPLACEABLE SHELLS P505-8 SERIES P PART NUMBER SIGNIFICANCE P360 SIZE (in 1/8 ) 505-8 TOTALINE FILTER DRIER SHELLS APPLICATION Totaline Replaceable Core Shells offer the

More information

Electrical Control Valves

Electrical Control Valves 172 Electrical Control Valves Electrical Control Valves Electrical Control Valve Technology Thermostatic expansion valves and mechanical regulator valves have been used in the refrigeration and air conditioning

More information

Capacity regulators (hot gas bypass) PMC and CVC

Capacity regulators (hot gas bypass) PMC and CVC MAKING MODERN LIVING POSSIBLE Technical brochure Capacity regulators (hot gas bypass) PMC and CVC The PMC and CVC is used for capacity regulation in refrigeration, freezing and air conditioning plant for

More information

Refrigeration Solenoid Valves & 3-Way Heat Reclaim Valves

Refrigeration Solenoid Valves & 3-Way Heat Reclaim Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Refrigeration Solenoid s & 3-Way Heat Reclaim s Catalog D-1, May 2010

More information

FDB Filter Drier. FDB Filter Drier. Technical Data

FDB Filter Drier. FDB Filter Drier. Technical Data Technical Data ALCO FDB is a hermetic filter-drier in compacted bead style for use on liquid line. Features Compacted bead style (spring loaded) Hermetic design Rugged steel shells Cushioned flow for non-turbulent

More information

EX4 / EX5 / EX6 / EX7 / EX8 Electrical Control Valves

EX4 / EX5 / EX6 / EX7 / EX8 Electrical Control Valves ALCO Controls EX4 / EX5 / EX6 / EX7 / EX8 are stepper motor driven valves for precise control of refrigerant mass flow in air conditioning, refrigeration, heat pumps, close control, and industrial process

More information

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller

More information

Application Data CONTENTS. COMPRESSOR PHYSICAL DATA (Table 1) Table 1 Open-Drive Compressors

Application Data CONTENTS. COMPRESSOR PHYSICAL DATA (Table 1) Table 1 Open-Drive Compressors Page COMPRESSOR PHYSICA DATA................. 1 OPEN-DRIVE COMPRESSORS................ 2-29 Operating Requirements......................... 2 Discharge Temperature.......................... 2 High Compression

More information

Thermostatic and Automatic Expansion Valves

Thermostatic and Automatic Expansion Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Thermostatic and Automatic Expansion Valves Catalog E-1, July 2012

More information

FILTER DRIERS PART NUMBER SIGNIFICANCE LIQUID LINE FILTER DRIERS TOTALINE LIQUID LINE FILTER DRIER PHYSICAL DATA DIMENSIONS

FILTER DRIERS PART NUMBER SIGNIFICANCE LIQUID LINE FILTER DRIERS TOTALINE LIQUID LINE FILTER DRIER PHYSICAL DATA DIMENSIONS TOTALINE LIQUID LINE FILTER DRIERS P502-8 SERIES P PART NUMBER SIGNIFICANCE P353 FEATURES Compacted bead filter drier Universal Replacement CFC, HCFC, HFC refrigerants Filtration first for more effective

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS INSTALLATION, START-UP AND SERVICE INSTRUCTIONS P705 Refrigeration Condensing Units CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INTRODUCTION.................................. 1 HANDLING.......................................

More information

Electronic suction modulating valves type KVS

Electronic suction modulating valves type KVS MAKING MODERN LIVING POSSIBLE Technical brochure Electronic suction modulating valves type KVS KVS is a series of electronic suction modulating valves for AC transport and refrigeration applications. Accurate

More information

Thermostatic expansion valves type TGE 10, TGE 20 and TGE 40

Thermostatic expansion valves type TGE 10, TGE 20 and TGE 40 MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves TGE 0, TGE 20 and TGE 40 TGE is a dedicated designed series of thermostatic expansion valves for all standard refrigerants.

More information

P70, P72, and P170 Controls for Low Pressure Applications

P70, P72, and P170 Controls for Low Pressure Applications Master Catalog 125 Pressure Controls Section P Product/Technical Bulletin Issue Date 0900 P70, P72, and P170 Controls for Low Pressure Applications The P70, P72, and P170 controls for low pressure applications

More information

ADK Filter Drier. Alco Controls. Filter Drier. Features

ADK Filter Drier. Alco Controls. Filter Drier. Features ADK is a hermetic filter-drier with internal solid block for use on liquid line. Features Solid block Hermetic design Rugged steel shells Corrosion resistant epoxy paint Solder connection made from copper

More information

April 2004 / BULLETIN for Supermarket Systems DDR-20 OLDR-15

April 2004 / BULLETIN for Supermarket Systems DDR-20 OLDR-15 April 2004 / BULLETIN 90-50 for Supermarket Systems DDR-20 OLDR-15 Page 2 / Bulletin 90-50 SPORLAN DEFROST DIFFERENTIAL PRESSURE REGULATING VALVES OFFER THESE BENEFITS: Able to maintain a differential

More information

Thermostatic expansion valves Type TGE 10, TGE 20 and TGE 40

Thermostatic expansion valves Type TGE 10, TGE 20 and TGE 40 MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic expansion valves Type TGE 10, TGE 20 and TGE 40 TGE is a dedicated designed series of thermostatic expansion valves for all standard refrigerants including

More information

Thermostatic expansion valves type TGE 10, TGE 20 and TGE 40

Thermostatic expansion valves type TGE 10, TGE 20 and TGE 40 MAKING MODERN LIVING POSSIBLE Technical brochure Thermostatic expansion valves TGE 0, TGE 20 and TGE 40 TGE is a dedicated designed series of thermostatic expansion valves for all standard refrigerants.

More information

EMERSON CLIMATE TECHNOLOGIES

EMERSON CLIMATE TECHNOLOGIES STAS STEEL TAKE-APART FILTER DRIER APPLICATION Replaceable core filter-drier for CFC, HCFC and HFC refrigerants for use in large commercial air conditioning and refrigeration systems. FEATURES Unique internal

More information

PIPING PACKAGES TABLE OF CONTENTS

PIPING PACKAGES TABLE OF CONTENTS PIPING PACKAGES TABLE OF CONTENTS ITEM PAGE General Notes and Legend........................................................ 3 Piping Package Code Descriptions & Diagrams VAV Products and HL, HP, VF, and

More information

V46 Series Pressure-Actuated Water-Regulating Valves

V46 Series Pressure-Actuated Water-Regulating Valves FANs 1, 11 Product/Technical Bulletin V46 Issue Date 9 V46 Series Pressure-Actuated Water-Regulating Valves The V46 pressure-actuated modulating valves come in two types of control action: direct acting

More information

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4- 4 (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants. DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants. FEATURES Pilot operated characterized Modulating Plug

More information

THERMOSTATIC EXPANSION VALVES

THERMOSTATIC EXPANSION VALVES PARKER TXV MODEL NUMBER SELECTION S MODEL E EXTERNAL EQUALIZER OPTIONAL 5 V X CHARGE TYPE 00 M.O.P. B BLEED OPTIONAL 0 BLEED S EG (C) C = Internal Check Valve (E) for externally equalized evaporator pressure

More information

The System Features These Advantages: Designing the Low Pressure Oil Return System

The System Features These Advantages: Designing the Low Pressure Oil Return System JANUARY 2004 / Bulletin 110-10 Sporlan s Oil Level Control System components were developed to offer the refrigeration industry an oil level control system of the highest quality. The heart of the system

More information

New Fan Coil Piping Packages

New Fan Coil Piping Packages New Fan Coil Piping Packages SO BUILT TOUGH, TOUGH. WE BUILT GUARANTEE TO LAST. IT. www.superiorrex.com Piping Packages Table of Contents General Notes and Legend... 3 Piping Package Code Descriptions

More information

Electric Expansion Valves

Electric Expansion Valves Electric Expansion s Bulletin 100-20-1, January 2011 Page 2 Bulletin 100-20-1UK This supplement to Bulletin 100-20 (September 2008) details the updated Sporlan series of Electric Expansion s. Built on

More information

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8 Electrical Control s Series EX4, EX5, EX6, EX7 & EX8 Features Multifunction as expansion valve, hot gas bypass, suction gas throttling, head pressure, liquid level actuator etc. Fully hermetic design (no

More information

FDB Filter Drier. Alco Controls. FDB Filter Drier. Features. Introduction. Moisture removal capability. Construction

FDB Filter Drier. Alco Controls. FDB Filter Drier. Features. Introduction. Moisture removal capability. Construction ALCO FDB is a hermetic filter-drier in compacted bead style for use on liquid line. Features Compacted bead style (spring loaded) Hermetic design Rugged steel shells Corrosion resistant epoxy paint Solder

More information

Pulse Width Modulation Valves. Models SPW-0 thru -7

Pulse Width Modulation Valves. Models SPW-0 thru -7 November 2017 Bulletin / Bulletin 30-30 30-30 Page 1 Pulse Width Modulation s Models SPW-0 thru -7 Page 2 Bulletin 30-30 Pulse Width Modulation s For Refrigerant Flow Control in Direct Expansion HFC, HCFC

More information

PIPING PACKAGES For Chilled and Hot Water Fan Coil Units

PIPING PACKAGES For Chilled and Hot Water Fan Coil Units WWW.KRUEGER-HVAC.COM PIPING PACKAGES For Chilled and Hot Water Fan Coil Units PROVIDING YOU WITH AIR DISTRIBUTION AND EQUIPMENT SOLUTIONS TABLE OF CONTENTS General Notes... 4 Code Descriptions... 5 Guide

More information

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING. MAKING MODERN LIVING POSSIBLE Solenoid valves EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

June 2015 / BULLETIN Catch-All. Liquid & Suction Line Filter-Driers FILTER-DRIERS. It s the CORE that counts!

June 2015 / BULLETIN Catch-All. Liquid & Suction Line Filter-Driers FILTER-DRIERS. It s the CORE that counts! June 2015 / BULLETIN 40-10 Catch-All Liquid & Suction Line Filter-Driers FILTER-DRIERS It s the CORE that counts! Page 2 Bulletin 40-10 Table of Contents The Sporlan Catch-All Liquid and Suction Line Filter-Driers

More information

C U S T O M E R D R I V E N R E S U L T S O R I E N T E D

C U S T O M E R D R I V E N R E S U L T S O R I E N T E D C O M P O N E N T S F O R T H E R E F R I G E R A T I O N A N D A I R C O N D I T I O N I N G I N D U S T R Y C U S T O M E R D R I V E N R E S U L T S O R I E N T E D C A T A L O G 1 0 9 E D I T I O N

More information

BFK Bi-flow Filter Drier

BFK Bi-flow Filter Drier ALCO is a hermetic Bi-flow filter-drier in solid block style for use on liquid line in reversible refrigeration systems such as heat pump units. Features Solid block style Integrated check valves insure

More information

Electric expansion valve Type ETS ETS 400

Electric expansion valve Type ETS ETS 400 MAKING MODERN LIVING POSSIBLE Data sheet Electric expansion valve Type ETS 12.5 - ETS 400 ETS is a series of electric expansion valves for precise liquid injection in evaporators for air conditioning and

More information

Electrically operated expansion valves, type ETS

Electrically operated expansion valves, type ETS MAKING MODERN LIVING POSSIBLE Technical brochure Introduction ETS is a series of electrically operated expansion valves for precise liquid injection in evaporators for air conditioning and refrigeration

More information

DANFOSS. Thermostatic Expansion Valves. Nominal Capacity Ranges in TR for Range N -40 to 50 F R-12 R-22 R-410A R-134A R-404A/

DANFOSS. Thermostatic Expansion Valves. Nominal Capacity Ranges in TR for Range N -40 to 50 F R-12 R-22 R-410A R-134A R-404A/ TYPE TUA(E), TUB(E), TUC(E), T(E)2, TDE, TDEB, TE, TXI 2, AKV Thermostatic Expansion Valves Valve Applications Features Models Nominal Capacity Ranges in TR for Range N -40 to 50 F R-12 R-22 R-410A R-134A

More information

Selection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING

Selection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING Selection & Application guidelines Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING www.danfoss.com 50 HZ BLUESTAR PRODUCT PROGRAMME....... p 3 Product

More information

P70, P72 and P170 Series Controls for High Pressure Applications

P70, P72 and P170 Series Controls for High Pressure Applications Installation Instructions P70 Issue Date October 16, 2002 P70, P72 and P170 Series Controls for High Pressure Applications Application P70, P72 and P170 Series Controls for High Pressure Applications provide

More information

MODULOAD CAPACITY CONTROL FOR 3D COMPRESSORS

MODULOAD CAPACITY CONTROL FOR 3D COMPRESSORS 21-1278 Application Engineering Bulletin AE-1278-R5 Revised February, 1997 MODULOAD CAPACITY CONTROL FOR 3D COMPRESSORS On refrigeration and air conditioning applications where the refrigeration load may

More information

Installation Instructions

Installation Instructions GEMINI SELECT 38APS025-050,38APD025-100 Air-Cooled Condensing Units with PURON Refrigerant (R-410A) 50/60 Hz Installation Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................

More information

VIFB Coil Technical Guide

VIFB Coil Technical Guide TGVIFB-5 VIFB Coil Technical Guide VERTICAL TUBE INTEGRAL FACE AND BY-PASS HEATING COILS FOR AIR PREHEATING Since 1875, the L.J. Wing Company has been a leader in providing innovative solutions for difficult

More information

This valve is designed to modulate flow of water or glycol to a water cooled condenser on a refrigeration system. ice machines. Pressure Element Style

This valve is designed to modulate flow of water or glycol to a water cooled condenser on a refrigeration system. ice machines. Pressure Element Style Code No. LIT-1973 Issued July 1, 6 V46 Series Pressure Actuated Water Regulating Valve Description The V46 is a pressure actuated, modulating valve that is suitable for use either on closed or open systems.

More information

SECTION Pressure & Temperature Control

SECTION Pressure & Temperature Control 16 Pressure & Temperature Control ARMSTRONG PRODUCT CATALOGUE 70 Pressure Reducing s Pressure Reducing s Armstrong pressure reducing valves (PRVs) and temperature regulators help you manage steam, air

More information

BULLETIN Type A4AM. March 2002 Installation, Service and Parts Instruction. Refrigerating Specialties Division Fig.

BULLETIN Type A4AM. March 2002 Installation, Service and Parts Instruction. Refrigerating Specialties Division Fig. Electrically Compensated Pressure Regulators Type A4AM, A4AOM, & A2BM PORT SIZE 3/8-4 (20MM-100MM) FOR AMMONIA, R22, R134A, R502 OTHER COMMON REFRIGERANTS FEATURES Unique modular construction Suitable

More information

Alco Controls. Components for the Refrigeration Industry. Product Selection Catalogue

Alco Controls. Components for the Refrigeration Industry. Product Selection Catalogue Alco Controls Components for the Refrigeration Industry Product Selection Catalogue Note: The components listed in this catalogue are not released for use with caustic, poisonous or flammable substances.

More information

EMERSON CLIMATE TECHNOLOGIES-EX

EMERSON CLIMATE TECHNOLOGIES-EX EMERSON CLIMATE TECHNOLOGIES-EX Valves & Controls EX4-EX8 Control Valve The EX4-EX8 are stepper motor driven valves that are optimized for the control of liquid or gaseous mass flow in refrigeration systems.

More information

HANDBOOK REFRIGERATING SYSTEM PROTECTORS. Ed REFRIGERATING SYSTEM PROTECTORS DP-ED 01/ ENG 1

HANDBOOK REFRIGERATING SYSTEM PROTECTORS. Ed REFRIGERATING SYSTEM PROTECTORS DP-ED 01/ ENG 1 HANDBOOK Ed. 2017 DP-ED 01/2017 - ENG 1 CHAPTER 3 Hermetic filter driers CERTIFIED BY UNDERWRITERS LABORATORIES INC. For refrigeration plants that use HCFC, HFC or HFO refrigerants APPLICATIONS The filters

More information

Thermo -Expansion Valves Series TX7

Thermo -Expansion Valves Series TX7 Technical Bulletin TX7 series of Thermo -Expansion Valves are designed predominantly for AC, heat pumps, close control and industrial process cooling applications. The TX7 is ideal for those applications

More information

New Fan Coil Piping Package. Redefine your comfort zone.

New Fan Coil Piping Package. Redefine your comfort zone. New Fan Coil Piping Package PIPING PACKAGES Table of Contents General Notes and Legend...3 Piping Package Code Descriptions & Diagrams THB, THH and TVB Fan Coils...4 TVS Fan Coil, 2-Way...5 TVS Fan Coil,

More information

FILTER DRIERS - SPORLAN

FILTER DRIERS - SPORLAN FILTER DRIERS - SPORLAN The universal acceptance of the Catch-All Filter-Drier is due to its unique moulded porous core, consisting of a blend of highly effective desiccants. The quality features built

More information

Electric expansion valves Type ETS 6

Electric expansion valves Type ETS 6 MAKING MODERN LIVING POSSIBLE Data sheet Electric expansion valves Type ETS 6 The range of Electric expansion valves are based on many years of experience. ETS 6 secure reliability and provide a precise

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet Solenoid valves EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 DKRCCPDBB0A202-520H275 Danfoss A/S, 0-2006 Contents Page Introduction.......................................................................................

More information

Modulating liquid level regulators, direct-controlled SV 1 and SV 3

Modulating liquid level regulators, direct-controlled SV 1 and SV 3 MAKING MODERN LIVING POSSIBLE Technical brochure Modulating liquid level regulators, direct-controlled SV 1 and SV 3 The SV 1 and 3 can be used separately as a modulating liquid level regulator in refrigerating,

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

Solenoid valves type EVR 2 40 NC / NO

Solenoid valves type EVR 2 40 NC / NO Solenoid valves type EVR 2 40 NC / NO Introduction EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. Features Complete range of solenoid

More information

HANDBOOK EXPANSION VALVES. Ed EXPANSION VALVES VE-ED 01/ ENG 1

HANDBOOK EXPANSION VALVES. Ed EXPANSION VALVES VE-ED 01/ ENG 1 HANDBOOK Ed. 2017 VE-ED 01/2017 - ENG 1 CHAPTER 12 STEP-MOTOR CERTIFIED BY UNDERWRITERS LABORATORIES INC. FOR REFRIGERATION PLANTS THAT USE HCFC, HFC OR HFO REFRIGERANTS belonging to Group 2, as defined

More information

Eliminator Liquid line filter driers, type DCL and DML

Eliminator Liquid line filter driers, type DCL and DML Eliminator Liquid line filter driers, type DCL and DML Flare connection Solder connection (copper) REFRIGERATION AND AIR CONDITIONING Technical leaflet Eliminator Liquid line filter driers, type DCL and

More information

Solenoid valve Types EVR 2 EVR 40 NC/NO

Solenoid valve Types EVR 2 EVR 40 NC/NO MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valve s EVR 2 EVR 40 NC/NO EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. EVR valves

More information

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1 HANDBOOK Ed. 2017 RP-ED 01/2017 - ENG 1 CHAPTER 2 CRANKCASE PRESSURE REGULATORS For refrigeration plants that use HCFC or HFC refrigerants shutter continues to open, until the stroke limit is reached and

More information

Electric expansion valve Type ETS ETS 400

Electric expansion valve Type ETS ETS 400 Data sheet Electric expansion valve Type ETS 12.5 - ETS 400 ETS is a series of electric expansion valves for precise liquid injection in evaporators for air conditioning and refrigeration applications.

More information

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C D E M A SINGLE-STAGE MODELS SINGLE-STAGE MODELS 1. PARTS A. Injector B. Backup washer (Models 204C & smaller). C. Ceramic Weight. D. Tubing 8 long w/ foot strainer. E. Three brass nozzle bushings Metering

More information

Technical leaflet Thermostatic expansion valves with fixed orifice

Technical leaflet Thermostatic expansion valves with fixed orifice MAKING MODERN LIVING POSSIBLE Technical leaflet Thermostatic expansion valves with fixed orifice Type TDE / TDEB www.danfoss.com Contents Page Introduction........................................................................................3

More information

AE R5 February 1997 Reformatted November 2010

AE R5 February 1997 Reformatted November 2010 AE21-1278 R5 February 1997 Reformatted November 2010 Moduload Capacity Control for 3D Compressors On refrigeration and air conditioning applications where the refrigeration load may vary over a wide range,

More information

Technical Information

Technical Information Date of last update: Sep 12 Ref: Application Engineering Europe COPELAND SCROLL COMPRESSORS USING VAPOUR INJECTION FOR REFRIGERATION CONTENTS 1 Introduction... 2 2 Principle of operation... 2 3 Capacity

More information

P70, P72, and P170 Series Controls for High Pressure Applications

P70, P72, and P170 Series Controls for High Pressure Applications Installation Instructions P70 Issue Date 0918 P70, P72, and P170 Series Controls for High Pressure Applications Application P70, P72, and P170 Series Controls for High Pressure Applications provide high-side

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS (1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece

More information

348002K/348012K Manifold Block Style Service Manual 12/2000

348002K/348012K Manifold Block Style Service Manual 12/2000 348002K/348012K Manifold Block Style Service Manual 12/2000 Service Manual 348002K/348012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation

More information

Sporlan Gas Cooler/ Flash Gas Bypass Valves

Sporlan Gas Cooler/ Flash Gas Bypass Valves Sporlan Gas Cooler/ Flash Gas Bypass Valves For Transcritical CO 2 (R-744) Applications August 14 / Bulletin 100-80 Page 2 Bulletin 100-80 Bulletin 100-80 Page 3 GAS COOLER/FLASH GAS BYPASS VALVES The

More information

Model Model Model

Model Model Model Filter Separators Model 9003 Model 9004 Model 9001 & 9032 Model 9002 EXAIR's Filter Separators remove water, dirt and rust from your compressed air system. They prevent these contaminants from plugging

More information

MAKING MODERN LIVING POSSIBLE. Eliminator Liquid line filter driers, DCL and DML. Flare connection. Solder connection (copper) Technical brochure

MAKING MODERN LIVING POSSIBLE. Eliminator Liquid line filter driers, DCL and DML. Flare connection. Solder connection (copper) Technical brochure MAKING MODERN LIVING POSSIBLE Eliminator Liquid line filter driers, DCL and DML Flare connection Solder connection (copper) Technical brochure Contents Page Introduction........................................................................................

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

ELIMINATOR Hermetic filter drier Types DCL and DML

ELIMINATOR Hermetic filter drier Types DCL and DML Data sheet ELIMINATOR Hermetic filter drier s DCL and DML All ELIMINATOR driers have a solid core with binding material held to an absolute minimum. There are two types of ELIMINATOR cores. DML driers

More information

Pressure and temperature regulators, type PM, and pilot valves

Pressure and temperature regulators, type PM, and pilot valves Pressure and temperature regulators, type PM, and pilot valves Introduction Main valves, type PM 1 and PM 3 Pilot valves for mounting directly into main valves, type PM Main valves, type PM 1 and PM 3

More information

Solenoid valves. Solenoid valves, type PKVD Solenoid valves, type EVR NC / NO

Solenoid valves. Solenoid valves, type PKVD Solenoid valves, type EVR NC / NO Solenoid valves Contents Page Solenoid valves, type PKVD 12-20 Introduction... 5 Features... 5 Technical data... 5 Ordering... 5 Capacity... 6 Sizing... 7 Valve selection... 7 Design/Function... 8 Dimensions

More information

Electric expansion valves Types AKVA 10, 15 & 20

Electric expansion valves Types AKVA 10, 15 & 20 Data sheet Electric expansion valves Types AKVA 10, 15 & 20 AKVA are electric expansion valves designed for ammonia refrigerating plant. The AKVA valves are normally controlled by a controller from Danfoss

More information

Technical brochure Electrically operated expansion valves, type ETS 6

Technical brochure Electrically operated expansion valves, type ETS 6 MAKING MODERN LIVING POSSIBLE Technical brochure Electrically operated expansion valves, type ETS 6 With many years of experience the current range of Electronic Expansion Valves offers high reliability

More information

Solenoid valves Type EVU for fluorinated refrigerants

Solenoid valves Type EVU for fluorinated refrigerants Data sheet Solenoid valves EVU for fluorinated refrigerants EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied

More information

Air-Cooled Screw Compressor Chiller

Air-Cooled Screw Compressor Chiller Installation, Operation and Maintenance Manual IOMM ALS Group: Chiller Part Number: 070774401 Date: February 1998 Supersedes: IM 548-3 Air-Cooled Screw Compressor Chiller ALS 070A through 425A 60 Hertz

More information

Rack Oil regulation and System Oil Failures

Rack Oil regulation and System Oil Failures Rack Oil regulation and System Oil Failures Bryan Lord 2009 Oil failure alarms are usually more than just a compressor safety control failure or low oil pressure event. Unfortunately OFC alarms are just

More information