1 TEST REPORT For Company: EiKO Global, LLC W. 84th Street, Shawnee, KS Model: LED6WG25/830K-DIM-G4 Report Type: Testing and Report According to ENERGY STAR Program Requirements for Lamps V1.0 Decorative LED Lamp 3000-hour Test Report (Dimming performance test was conducted and reported by lamp manufacturer and is not included in this report) Test Date: to Test Engineer: Bill Xiong Daniel Duan Report Number: Report Date: Reviewed By: Test Facility: Prepared By: Jeanne Han/Safety Manager Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: Fax: Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. Some of the tests or test methods in this report may not in NVLAP accreditation scope and was noted. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

2 TABLE OF CONTENTS 1 PRODUCT DESCRIPTION STATEMENT OF TRACEABILITY SUMMARY OF TEST RESULTS DETAILED TEST METHODS AND TEST RESULTS IN SITU TEMPERATURE MEASUREMENT TEST INITIAL PHOTOMETRIC AND ELECTRICAL MEASUREMENTS LUMINOUS INTENSITY DISTRIBUTION START TIME FREQUENCY TRANSIENT PROTECTION RAPID CYCLE STRESS TEST LUMEN MAINTENANCE AND COLOR MAINTENANCE EUT PHOTO LAMP PROFILE LAMP OPTICS LED BOARD PHOTO DRIVER PHOTO DRIVER PHOTO Report No Page 2 of 25 The NVLAP Lab Code is

3 1 Product Description General Information: 27PCS samples were received on and used for testing. Samples were numbered 505-S01 through 505-S27. Model Tested: Manufacturer: Lamp Shape: Lamp Type: Lamp Base: Dimming: Application Exceptions: Restricted Position: LED6WG25/830K-DIM-G4 EiKO Global, LLC G25 Decorative LED Lamp E26 Dimmable Not for use in enclosed fixtures None. Rated Values: Rated Voltage/Frequency: Rated Power: Nominal Light Output: Nominal CCT: Rated Life: Wattage Equivalency Claims: AC 120V 60 Hz 6W 450 lm 2700 K hours 40W LED Light Source Information: LED Type: LED Package LED Model Number: 5630(STWxQ14x) Number of LED Source: 13 LED Manufacturer: SEOUL SEMICONDUCTOR Co.,Ltd 2 Statement of Traceability Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI). Report No Page 3 of 25 The NVLAP Lab Code is

4 3 Summary of Test Results Criteria Item Measured Value (Avg.) Reported Value Result Reference Standard Accreditation Requirement Efficacy (lm/w) /10 Pass IES LM YES Light Output (lm) /10 Pass IES LM YES 8 of the 10 lamps and report value: 45 lm/w 8 of the 10 lamps and report value: lm Zonal Lumen Density 18.59% N/A Pass IES LM YES 5% in zone CCT (K) /10 Pass CRI Pass R Pass Power Factor Pass IES LM CIE ANSI/ANSLG C IES LM CIE ANSI/ANSLG C IES LM CIE ANSI/ANSLG C IES LM ANSI C YES NO 9 of the 10 lamps fall within a 7-step ANSI quadrangle YES Average R a 80, less than 3 units R a <77 NO and none lower than 75 YES NO Average R 9 > 0 YES Reported value 0.7 Start Time (ms) Pass ENERGY STAR Test Method: Start Time Test YES Reported value 1 s Transient Protection See tables N/A 5/5 Pass ANSI/IEEE C YES Survival after 7 strikes of a 100 khz ring wave, 2.5 kv level Frequency (Hz) i N/A Pass None NO 120Hz Overall Length (mm) i N/A Pass ANSI C NO None Diameter (mm) i N/A Pass ANSI C NO Lamp maximum outside diameter shall be within±15% of the lamp nominal diameter Report No Page 4 of 25 The NVLAP Lab Code is

5 Criteria Item Measured Value (Avg.) Reported Value Rapid-Cycle Stress Test See tables 6 6/6 Pass 3000-hour Color Maintenance 3000-hour Lumen Maintenance /10 Pass Bay Area Compliance Laboratories Corp. (Shenzhen) Result Reference Standard Accreditation Requirement ANSI C IES LM (clauses 4, 5, 6) IES LM ANSI/ANSLG C YES 5 of the 6 lamps: 7500 YES NO 9 of the 10 lamps: % 96.5% Pass IES LM YES Average 93.1% Life Test at 3000-hour N/A N/A 10/10 Pass ENERGY STAR Test Method: ATLT YES All tested units shall be operational Projected L 70 Life for Early Interim Certification(hr) ii >36000 N/A Pass IES TM NO 15,000 hours 6000-hour Color Maintenance 6000-hour Lumen Maintenance TBD TBD TBD IES LM ANSI/ANSLG C YES NO 9 of the 10 lamps: TBD TBD TBD IES LM YES Reported value 86.7% Life Test at 6000-hour TBD TBD TBD ENERGY STAR Test Method: ATLT YES 90% of the tested units shall be operational Note: i. Frequency, overall length and diameter test are not in NVLAP accreditation scope. ii. TM-21 Calculator was used to project the L 70 life based on lumen maintenance report of LED package/ array/ module (LM test report). iii. Dimming performance test was conducted and reported by lamp manufacturer and is not included in summary. Report No Page 5 of 25 The NVLAP Lab Code is

6 4 Detailed Test Methods and Test Results 4.1 In situ Temperature Measurement Test Test Method: ANSI/UL Standard for Safety of Self-Ballasted Lamps and Lamp Adapters IES TM-21-11: Projecting Long Term Lumen Maintenance of LED Light Sources (This method is not in NVLAP accreditation scope) Performance Requirements: It is required for early interim certification to calculate the projected L 70 life. The projected lumen maintenance life shall be greater than or equal to the lamp rated life value to be claimed on product packaging. For family products, the average of five in situ temperatures of critical components shall be no greater than 2.5 C above the same average of in situ temperatures in a sample of five units of the tested representative model. Critical components include the highest temperature LED package/array/module measured at TMP LED, LED driver measured at TMP C, capacitors and fuses. The TMP LED should not be greater than the maximum case temperature tested in the corresponding IES LM-80 report. Test Procedure: Tests were conducted at 25 ± 5 C. Thermocouples and hybrid recorder were used to test the temperature of highest temperature LED measured at TMP LED, LED driver measured at TMP C, capacitors and fuses. According to ANSI/UL 1993, the lamp was operated base up at rated voltage in temperature test box. The bottom of box shall be closed off with a 2.5 mm (0.1 in) thick piece of window glass of appropriate size, except lamps labeled not for use in enclosed or recessed fixtures or equivalent. The reported temperature value for each point should be the readings of the hybrid recorder after the temperature of each point is stabilized and constant. A temperature is considered constant if the test has been running for at least 3 hours; and three successive readings, taken at 15-minute intervals, are within 1 degree C of one another and are not rising. Or the test was run for a minimum of 7.5 h. Ambient temperature variations above or below 25 C have been respectively subtracted from or added to temperatures recorded at points on the luminaire. The drive current of LED package/module/ array was calculated as the total output current of the driver measured by multimeter, divided by the number of branches in parallel of LEDs. Test Equipment: Device Manufacture Model No Serial No Test Range date due date Power Supply HengPu HPA KVA Multimeter Fluke 17B ~1000V 0~10A 0~300MΩ Hybrid Recorder YOKOGAWA DR240 10# 0~ Uncertainty: The uncertainty of the temperature is U= C (K=2), at the 95% confidence level. Report No Page 6 of 25 The NVLAP Lab Code is

7 Test Data: Photo of test location: TMP LED Supply voltage: AC 120 V Type of thermocouples: T Test Duration: 3.5 hours Sample No. TMP LED (ºC) Drive Current (ma) 505-S For the life projection, see Attachment A - LM test report and TM-21 Calculator Report No Page 7 of 25 The NVLAP Lab Code is

8 4.2 Initial Photometric and Electrical Measurements Test Method: Bay Area Compliance Laboratories Corp. (Shenzhen) IES LM-79-08: Electrical and Photometric Measurements of Solid-State Lighting Products ANSI/ANSLG C : Specifications for the Chromaticity of Solid State Lighting Products CIE Pub. No : Method of Measuring and Specifying Color Rendering of Light Sources CIE Pub. No. 15:2004: Colorimetry ANSI C Harmonic Emission Limits-Related Power Quality Requirements for Lighting Equipment Performance Requirements: Luminous Efficacy: Reported values for each lamp model shall meet the applicable requirement in the ENERGY STAR specification. Additionally eight or more units individually shall meet the requirement. Light Output: For omnidirectional and decorative lamps, Reported lamp initial light output (in lumens) shall fall within the range of the referenced incandescent lamp listed in the ENERGY STAR specification. For R, BR and ER lamps, reported lamp initial light output (in lumens) shall be greater than or equal to the incandescent lamp s rated wattage times the multiplier required in the ENERGY STAR specification. Additionally 8 or more units individually shall meet the requirement. No requirements for MR and PAR lamps. CCT: Reported lamp model light color temperature shall correlate to one of the required nominal CCTs, additionally 9 out of 10 units shall fall within a 7-step ANSI quadrangle for the designated CCT. CRI: The average R a 80 and R 9 >0. No more than 3 units shall have R a < 77. No unit shall have R a < 75 Power Factor: 0.7 for lamps >5W. Test Procedure: According to IES LM-79-08, LED lamps were tested at ambient temperature 25 C±1 C with no seasoning. Initial parameters including Total Light Output (luminous flux), Correlated Color Temperature (CCT), Color Rendering Index (CRI), Luminous Efficacy, Chromaticity Coordinate, Current, Power, and Power Factor, were measured 5 base-up and 5 base-down by integrating sphere system. This system including spectrophotometer, integrating sphere, digital power meter, DC power supply and AC power supply, was calibrated by standard light source before measurement. Spectral measurement was taken at 5 nm intervals from 350 to 780 nm. The u, v and Duv was calculated based on measured x, y in accordance with CIE Pub. No.15:2004 and ANSI/ANSLG C and rounded to four decimal places. Other test results were derived by software of test equipment and were recorded with no rounding. Test Equipment: Device Manufacture Model No Serial No Test Range date due date Integrating Sphere SENSING N/A N/A Power Meter SENSING UI V Spectral photometer SENSING SPR3000 s nm~800nm AC Power Supply ALL Power APW-105N V-300V Hz Report No Page 8 of 25 The NVLAP Lab Code is

9 Device Manufacture Model No Serial No Test Range Standard Light Source Bay Area Compliance Laboratories Corp. (Shenzhen) date due date EVERFINE D N/A Thermal Meter SENSING N/A T-08-EE DC Power Supply ITECH IT ~32V Uncertainty: The uncertainty of the light output (luminous flux) measurements is U=1.60% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=1.3(K=2), at the 95% confidence level. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Test Data: Sample No. Orientation Voltage (V) Current (A) Power (W) 505-S S S S S05 Power Factor Luminous Flux (lm) Efficacy (lm/w) CCT (K) VBU VBU VBU VBU VBU Average VBU S S S S S10 VBD VBD VBD VBD VBD Average VBD Average ALL Report No Page 9 of 25 The NVLAP Lab Code is

10 Sample No. Orientation CRI R 9 x y u v Duv 505-S S S S S05 VBU VBU VBU VBU VBU Average VBU S S S S S10 VBD VBD VBD VBD VBD Average VBD Average ALL step chromaticity quadrangles per ANSI/ANSLG C step 2700K 0.41 Center Point 0.40 Result Report No Page 10 of 25 The NVLAP Lab Code is

11 4.3 Luminous Intensity Distribution Test Method: IES LM-79-08: Electrical and Photometric Measurements of Solid-State Lighting Products Performance Requirements: No less than 5% of total flux (lumens) shall be emitted in the 110 to 180 zone. Test Procedure: According to IES LM-79-08, LED lamps were tested at ambient temperature 25 C±1 C with no seasoning. Luminous Intensity distribution was measured by type C goniophotometer. One sample was measured and operated at base-up orientation. Sample was motionless and its position was unchanged during test. After measurement of a vertical plane sample was rotated 22.5ºaround the lamp polar axis. Sample was operated at rated voltage and was tested after stabilized according to IES LM The center beam intensity is that the value of light flux intensity in candelas (cd) measured on the beam axis. According to ENERGY STAR specification, the beam angle in degrees is between the two opposite directions in which the average intensity is 50% of the center beam intensity as measured in two rotational planes, 90ºfrom each other, around and through the beam axis. Test Equipment: Device Manufacture Model No Serial No Test Range AC Power Supply EVERFINE VPS1060 PWM date due date V, 0-300V DC Power Supply EVERFINE WY V/5A Power Meter YOKOGAWA WT KB35700 N/A Goniophotometer EVERFINE GO-R5000 YG108492N mm,3000W/10A Thermal Meter Victor VC230 EE091 0~40 0~90% Standard Light Source EVERFINE D N/A Uncertainty: The uncertainty of the luminous intensity is U=2.82% (K=2), at the 95% confidence level. Report No Page 11 of 25 The NVLAP Lab Code is

12 Test Data: Luminous Intensity Distribution Diagram Sample No. Orientation Beam Angle (Deg) CBCP (cd) 505-S11 VBU Zonal Lumen Density Deg Flux (lm) % Deg Flux (lm) % Report No Page 12 of 25 The NVLAP Lab Code is

13 4.4 Start Time Test Method: ENERGY STAR Test Method: Start Time Test Performance Requirements: Reported value of time for lamp to remain continuously illuminated shall be within one second of application of electrical power. Test Procedure: Integrating sphere, oscilloscope, photocell were used during start time test. Lamps shall be stored at 25 C ± 5 C for a minimum of 16 hours prior to the test, after which the temperature range shall be 25 C ± 1 C for at least two hours immediately prior to the test. amps were tested at rated voltage. The start time is defined that the time between the application of power to the device and the point where light output reaches 98% of the lamp s initial plateau. Test Equipment: Device Manufacture Model No Serial No Test Range 2.0m integrating sphere Digital Power Meter AC Power Supply Digital real-time oscilloscope date due date EVERFINE R N/A EVERFINE PF2010A V/20A EVERFINE TEKTRONIX INC.BEAVERT ON,OR.U.S.A DPS1010- YF T N/A TDS 220 C MHz,1 GS/s Sensor EVERFINE V N/A N/A N/A Uncertainty: The uncertainty of Operating Frequency U=0.6% (K=2), at the 95% confidence level. Test Data: Test date: ; Test voltage: 120V 60Hz Sample No. Base Orientation Time base (ms/div) Starting time (ms) 505-S01 VBU S02 VBU S03 VBU Average VBU Report No Page 13 of 25 The NVLAP Lab Code is

14 Figure of Input voltage and light output waveforms 505-S01 Bay Area Compliance Laboratories Corp. (Shenzhen) Thumbs.db 505-S S03 Report No Page 14 of 25 The NVLAP Lab Code is

15 4.5 Frequency This test is not in NVLAP accreditation scope. Performance Requirements: Lamp light output shall have a frequency 120Hz. Test Procedure: Lamps were tested at rated voltage after stabilized. No dimmer or transformer was used during test. Test Equipment: Device Manufacture Model No Serial No Test Range Rapid recording photometer 2.0m integrating sphere Digital Power Meter Special zerovoltage synchronous switching AC Uncertainty: EVERFINE PHOTO- 2000F date due date lm 200klm EVERFINE R N/A EVERFINE PF2010A V/20A EVERFINE DPS1010- YF The uncertainty of Operating Frequency U=0.6% (K=2), at the 95% confidence level. Test Data: Sample No. Base Orientation Frequency (Hz) 505-S01 VBU T N/A Report No Page 15 of 25 The NVLAP Lab Code is

16 Digitized photometric waveform Report No Page 16 of 25 The NVLAP Lab Code is

17 4.6 Transient Protection Test Method: ANSI/IEEE C : IEEE Recommended Practice on Characterization of Surges in Low Voltage (1000V and Less) AC Power Circuits. Category A Location. Performance Requirements: Lamp shall survive 7 strikes of a 100 khz ring wave, 2.5 kv level. All units shall be fully operational at the completion of testing. Test Procedure: The sample was operated at rated voltage in its designated orientation during the test. Seven strikes of 2500V (0.5us 100 khz Ring Wave) were performed on lamp base in accordance with ANSI/IEEE C62.41 (Category A). Test Equipment: Device Manufacture Model No Serial No Test Range date due date AC Power source HengPu HPA KVA MODULAR IMPULSE GENERATOR EMC- PARTNER MIG0603IN1 IEC-ANSI 593 N/A Uncertainty: The uncertainty of voltage U=1.07% (K=2), at the 95% confidence level. The uncertainty of time U=0.6% (K=2), at the 95% confidence level. Test Data: Sample No. 505-S S S S S23 Test Result Survival Survival Survival Survival Survival Report No Page 17 of 25 The NVLAP Lab Code is

18 4.7 Rapid Cycle Stress Test Test Method: IES LM-65-10: Life Testing of Compact Fluorescent Lamps Performance Requirements: Lamp, when cycled at 2 minutes on, 2 minutes off, or 5 minutes on 5 minutes off, shall survive the lesser number of cycles: one cycle per hour of rated life or 15,000 cycles. At least 5 units shall survive the minimum number of cycles. Test Procedure: 6 lamps were operated base-up at rated voltage and operating cycle is 5minutes on, 5minutes off until they burned out or reach the times requested. The input voltage was monitored and regulated to within ± 2 percent of the rated rms value for the duration of the test. Ambient temperature was controlled between 20 C and 35 C. Test Equipment: Device Manufacture Model No Serial No Test Range date due date Relay OMRON DH48S-S EE157 N/A AC POWER SUPPLY HPC HPC-3190 (90KVA) V Hz Thermal Meter Victor VC230 QA046 N/A Uncertainty: The uncertainty of the timer U=0.5s (K =2), at the 95% confidence level. Test Data: Sample No. Orientation Number of Cycle 505-S12 VBU S13 VBU S14 VBU S15 VBU S16 VBU S17 VBU Report No Page 18 of 25 The NVLAP Lab Code is

19 4.8 Lumen Maintenance and Color Maintenance Test Method: Bay Area Compliance Laboratories Corp. (Shenzhen) IES LM-79-08: Electrical and Photometric Measurements of Solid-State Lighting Products CIE Pub. No. 15:2004: Colorimetry ENERGY STAR Test Method: Ambient Temperature Life Testing Performance Requirements: Lamp change in chromaticity from 0-hour measurement, at any measurement point during the first 6,000 hours of lamp operation, shall be within a total distance of on the CIE 1976 u v diagram. Nine or more units shall meet the requirement. Lamp shall maintain minimum percentage of 0-hour light output after completion of the specific test duration per the tables in ENERGY STAR specification. The reported values shall be the average lumen maintenance of 9 surviving units and shall meet the minimum requirement for the designated life claim. All tested units shall be operational at 3,000 hours. 90% of the tested units shall be operational at 6,000 hours. Test Procedure: Ten lamps were operated to test both of lumen maintenance and color maintenance. This test would be suspended for Photometric measurement: after 3000 hours for initial qualification with LM-80 report; after 6000 hours for full qualification; and after more than 6000 hours for rated life more than hours. Lamps were tested in accordance with the ENERGY STAR Ambient Temperature Life Test in an ambient temperature condition between 20 C and 35 C Test Equipment: Device Manufacture Model No Serial No Test Range date due date Integrating Sphere SENSING N/A N/A Power Meter SENSING UI V Spectral photometer SENSING SPR3000 s nm~800nm AC Power Supply ALL Power APW-105N V-300V Hz Standard Light Source EVERFINE D N/A Thermal Meter SENSING N/A T-08-EE DC Power Supply ITECH IT6154 AC POWER SUPPLY N/A HPC-3160 (60KVA) ~32V V Hz N/A N/A Thermal Meter Victor VC230 EE094 0~40 0~90% Report No Page 19 of 25 The NVLAP Lab Code is

20 Device Manufacture Model No Serial No Test Range date due date Thermal Meter Victor VC230 EE209 0~40 0~90% Thermal Meter Victor VC ~40 0~90% Thermal Meter Victor VC230 QA047-20~ Uncertainty: The uncertainty of the light output (luminous flux) measurements is U=1.60% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=1.3(K=2), at the 95% confidence level. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level. Test Data: (Next Page) Report No Page 20 of 25 The NVLAP Lab Code is

21 3000 Hours Photometric Measurement Sample No. Orientatio n 3000-hour Luminous Flux (lm) % of Initial Luminous Flux 3000-hour u 3000-hour v Color Maintenan ce Burned Hours 505-S01 VBU % S02 VBU % S03 VBU % S04 VBU % S05 VBU % Average VBU % N/A 505-S06 VBD % S07 VBD % S08 VBD % S09 VBD % S10 VBD % Average VBD % N/A Average ALL % N/A 6000 Hours Photometric Measurement Sample No. Orientatio n 6000-hour Luminous Flux (lm) % of Initial Luminous Flux 6000-hour u 6000-hour v Color Maintenan ce Burned Hours 505-S01 VBU TBD TBD TBD TBD TBD TBD 505-S02 VBU TBD TBD TBD TBD TBD TBD 505-S03 VBU TBD TBD TBD TBD TBD TBD 505-S04 VBU TBD TBD TBD TBD TBD TBD 505-S05 VBU TBD TBD TBD TBD TBD TBD Average VBU TBD TBD TBD TBD TBD N/A 505-S06 VBD TBD TBD TBD TBD TBD TBD 505-S07 VBD TBD TBD TBD TBD TBD TBD 505-S08 VBD TBD TBD TBD TBD TBD TBD 505-S09 VBD TBD TBD TBD TBD TBD TBD 505-S10 VBD TBD TBD TBD TBD TBD TBD Average VBD TBD TBD TBD TBD TBD N/A Average ALL TBD TBD TBD TBD TBD N/A Report No Page 21 of 25 The NVLAP Lab Code is

22 5 EUT PHOTO 5.1 Lamp profile LED6WG25/830K-DIM- G4 5.2 Lamp optics LED6WG25/830K-DIM- G4 Report No Page 22 of 25 The NVLAP Lab Code is

23 5.3 LED Board Photo 5.4 Driver photo 1 Report No Page 23 of 25 The NVLAP Lab Code is

24 5.5 Driver photo 2 Report No Page 24 of 25 The NVLAP Lab Code is

25 Attachment A - LM test report and TM-21 Calculator **********END OF REPORT********** Report No Page 25 of 25 The NVLAP Lab Code is

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED15WA21/300/830K-GU24-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED11WA19/300/840K-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED11WA19/300/827K-GU24-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India IES LM-79-08 MEASUREMENT AND TEST REPORT For Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida 201305 UP India Test Model: L14EH80-W/HB/50K Report Type: Electrical and Photometric

More information

IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO62727W/V2

IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO62727W/V2 IES LM-79-08 MEASUREMENT AND TEST REPORT For MaxLite Inc 12 York Ave West Caldwell, NJ. 07006 Test Model: RRECO62727W/V2 Report Type: Test Engineer: Electrical and Photometric tests including: Luminous

More information

IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO81227W/V2

IES LM MEASUREMENT AND TEST REPORT For. MaxLite Inc 12 York Ave West Caldwell, NJ Test Model: RRECO81227W/V2 IES LM-79-08 MEASUREMENT AND TEST REPORT For MaxLite Inc 12 York Ave West Caldwell, NJ. 07006 Test Model: RRECO81227W/V2 Report Type: Electrical and Photometric tests including: Luminous Flux, Chromaticity,

More information

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India IES LM-79-08 MEASUREMENT AND TEST REPORT For Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida 201305 UP India Test Model: L20H80/50K Report Type: Electrical and Photometric tests

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou,

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) SANHUI INDUSTRY ZONE CUNWEI VILLAGE HENGLI TOWN DONGGUAN GUANGDONG 523000 CN Outdoor Wall-Mounted Area

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-2000LM-3000K Representative (Tested) Model: RPT-LEDBIAX-2000LM-3000K

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8024M40-A LED-8024-CW-E40-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8033E40-A LED-8033-CW-E27-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8033E57-A LED-8033-DL-E27-A Remark: The two models are the same

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Fujian Lightning Optoelectronic Co., Ltd.Shenzhen Branch 5F, Building B, second phase of Chuangjian Industrial

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8046M40-A LED-8046-CW-E40-A Remark: The two models are the same

More information

LIGHT EFFICIENT DESIGN, LLC

LIGHT EFFICIENT DESIGN, LLC LM-79-08 Test Report For LIGHT EFFICIENT DESIGN, LLC (Brand Name: N/A) 188 S.Northwest Highway, Cary, IL60013, USA LED Luminaires Model name(s): LED-7320-40K-G2 Representative (Tested) Model: LED-7320-40K-G2

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

MEASUREMENT AND TEST REPORT

MEASUREMENT AND TEST REPORT IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E57-A LED-8038-DL-E27-A Remark: The two models are the same

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8046M57-A LED-8046-DL-E40-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8030M57-A Representative (Tested) Model: LED-8030M57-A Model Different

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8036M40-A Representative (Tested) Model: LED-8036M40-A Model Different

More information

LIGHT EFFICIENT DESIGN

LIGHT EFFICIENT DESIGN LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E40-A LED-8038-CW-E27-A Remark: The two models are the same

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E30-A LED-8038-NW-E27-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8050M50-HV Representative (Tested) Model: LED-8050M50-HV Model Different

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8029E40-A LED-8029M40-A Remark : The suffix of the model name E stand

More information

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006 LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP35AUT550BPCMA Test & Report By: Sean Zhuo Engineer:

More information

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For HOCAN GROUP CO.,LTD (Brand Name: SEPICN LED LIGHTING) Rm.1902, Easey Comm. Bldg., 253-261 Hennessy Road,Wanchai, Hong Kong Direct Linear Ambient Luminaires Low-bay Luminaires for

More information

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT LM-79-08 Test Report For Model Different: All construction and rating are the same, except CCT Test & Report By: Review By: Sean Zhuo Engineer: Sean Zhuo Date: Apr.24,2015 Manager: Tommy Liang Note: This

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8029E57-A LED-8029M57-A Remark : The suffix of the model name E stand

More information

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For HOCAN GROUP CO.,LTD (Brand Name: SEPICN LED LIGHTING) Rm.1902, Easey Comm. Bldg., 253-261 Hennessy Road,Wanchai, Hong Kong Direct Linear Ambient Luminaires Low-bay Luminaires for

More information

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Luminaire Model name(s): LED-8050M50 Representative (Tested) Model: LED-8050M50 Model Different

More information

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA LM-79-08 Test Report For MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA OUTDOOR FULL-CUTOFF WALL-MOUNTED AREA LUMINAIRES Model name(s): BP45AUT5XXBPM0 BP45AUT5XXWPM0 Remark: The

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. LED LAMP Model name(s): TLFLF220XYYZZ Remark:The letter

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. LED LAMP Model name(s): TLFLF80XYYZZ Remark:The letter

More information

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA LM-79-08 Test Report For MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA Four-Foot Linear Replacement Lamps Model name(s): MT8Z04 Representative (Tested) Model:

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006 LM-79-08 Test Report For MAXLITE INC (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): PTD100UT341SMxxx Representative (Tested)

More information

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED) LM-79-08 Test Report For SNC OPTO ELECTRONIC CO.,LTD (Brand Name: SNC LED) Block 6,Zhengdaan Industry Park,No.172,Xiangshan Road,Luotian Village, SongGang Town,Baoan District,Shenzhen Replacement Lamps

More information

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For SHENZHEN MTC LIGHTING CO., LTD. NO.65,Chuangyi Road,Dalang Street,Baoan District,Shenzhen,GuangDong Province,CHINA

More information

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED) LM-79-08 Test Report For SNC OPTO ELECTRONIC CO.,LTD (Brand Name: SNC LED) Block 6,Zhengdaan Industry Park,No.172,Xiangshan Road,Luotian Village, SongGang Town,Baoan District,Shenzhen Replacement Lamps

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou, China Model:40B18C12(Ra2) Report Type: 10000

More information

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503 LM-79-08 Test Report For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): IGTWP-0301550 (5000K) Model Difference:

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Room 316, Building 2, No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou, China Model:100B10C10(Ra2)

More information

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0.

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0. LED Wall-PACK/Flood Light DataSheet Cat# 71391 Wet Locations Use RoHS QPL ID # PSQKCNWM Model: 71391 Input Voltage 100-277VAC Input Current 0.5A @100V / 0.2A @277V Input Power 28 W OVERALL LAMP PARAMETERS

More information

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, ,

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, , Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, +91

More information

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS LED Wall-PACK/FloodLight DataSheet Cat# 71393 Model: RoHS Wet Locations Use 71393 Input Voltage 100-277VAC Input Current 0.69A @120V / 0.31A @277V Input Power 79 W Power Factor PF 0.95 OVERALL LAMP PARAMETERS

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08239-001A LN4-34L-40K-xxx Date: 05/13/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09173-004B IG-NM-5S-A-30K-UL-WH xxx Date: 09/21/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Zongjie

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06624-001A VG-A-xx-5W-A-57K-UL w/ VG-PSSV Date: 08/20/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Revolution Lighting Technologies, Inc 2280 Ward Ave. Simi Valley, CA. 93065 Roman Sukharev, (877)

More information

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black Catalog Number 71376 UPC Number 601986713764 Description LED Bullet Flood Light 30 W 2300 Lumens Features Cree CXA LED s, CRI: 70+ Voltage: 120-277VAC Isolated Driver Compartment for Optimal Thermal Management

More information

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black Catalog Number 71372 UPC Number 601986713726 Description LED Bullet Flood Light 1 LED 800 Lumen Features Cree CXA LED s, CRI: 70+ Voltage: 120-277VAC Isolated Driver Compartment for Optimal Thermal Management

More information

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146,

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146, Photometric Test Report Relevant Standards IES LM-79-2008 Prepared For MaxLite Inc 0 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x46, rraghavan@maxlite.com Catalog Number BLHE-223DU50-[blank,

More information

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA LM-79-08 Test Report For Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 1130SG-35T Remark:

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL13048-001A CR4T-790L-27K-12-E26GU24 Date: 08/22/18 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy Lehrmann

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 77- Report Number: Model: PL-1 BXSPCxx2LGE3K-xxxxxx w/xa-sp1bls or XSPCxx2LGE3 Date: 8/8/21 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG Customer Company & Address: GREEN CREATIVE ADD: Room 1206-7 New Victory House, 93-103 Wing Lok Street, Central, HONG KONG Contact Person: Guillaume Vidal Telephone: +86 21-62320308 Email address: guillaume@gc-lighting.com

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07003-001A RUL-HT-5ME-C-40K-12-UF-N-ES-K2 Date: 12/16/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Michael Hash

More information

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W Customer Company & Address: MaxLite ADD: 12 York Ave, West Caldwell, NJ 07006 Contact Person: Francisco Garza Telephone: 973-244-7300x142 Telephone: fgarza@maxlite.com Manufacturer: Country of Origin:

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L121500401 Date: 12/8/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121500401 Report Prepared For: Bartco Lighting 5761 Research

More information

Calibration Due Date Chroma Programmable AC Source 61604

Calibration Due Date Chroma Programmable AC Source 61604 Test #: L12132802 Date: 12/18/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L12132802 LW52-BRZ-110-00 Report Prepared For:

More information

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Osram Sylvania 200 Ballardvale Street Wilmington, Mass Report No: L071407402 Date: 7/30/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071407402 Report Prepared For: Osram Sylvania 200 Ballardvale

More information

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260 PHOTOMETRIC TESTING & EVALUATION Sample Tested Man-D-Tec UNILED-12-4K Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260 Phone: 480-998-0325 Technical Report Number 70150753 August 8, 2017

More information

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard LM-79 Test Report Test Request Number 0980103 Lamp specifics: Luminaire Used: EAMD0R541L1CBLCK Rated Watts Voltage: 91 Watts Lamp Type: Type Type V Round V Round Sym w Evolve Sym w LED Rated Orientation

More information

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 LM 79 08 Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 Model(s) This test report presents the results of measurements performed on the product Spectrum Lighting SX1605RDLED18W35KE1/SM/OP

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L08133001 Date: 8/22/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L08133001 LUX-LED-360-4R-UNV-U Report Prepared

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions. Report No: L031610901 Date: 4/7/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L031610901 Report Prepared For: Osram Sylvania, Inc. Model

More information

Report of Test LLIA A-R02*

Report of Test LLIA A-R02* Report of Test LLIA000762-006A-R02* *This test report supersedes test report LLIA000762-006A-R01 each. Two Osram Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000901-044A One ERP ESP050W-1200-42 LED driver 120.0Vac, 60.00Hz, 0.3999A, 47.20W, 0.984PF, 11.8%THD(i) Total Light Output Luminaire Power Luminous Efficacy Performance Summary 3548

More information

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 LM-79-08 Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 Model(s): Sylvania LED10A19/F/827/RP (Sample 28) 13 June 2013 This test report presents the results of measurements performed

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000930-001A Catalog Number: AR300-D-MO-K40-80--4-XX-LOH-XXXX-120 One Osram Optotronic OTi 30/120-277/1A0 DIM L LED driver 120.0Vac, 60.00Hz, 0.1556A, 18.56W, 0.994PF, 5.2%THD(i) Total

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000930-002A Catalog Number: AR300-D-HO-K40-80--4-XX-LOH-XXXX-120 One Osram Optotronic OTi 30/120-277/1A0 DIM L LED driver 120.0Vac, 60.00Hz, 0.2331A, 27.89W, 0.997PF, 5.9%THD(i) Total

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000930-008A Catalog Number: AR300-I/D-HO/HO-K40-80--4-XX-WSCL/LOH-XXXX-120 One Osram Optotronic OTi 85/120-277/2A0 DIMLT2 L LED driver 120.0Vac, 60.00Hz, 0.4998A, 59.53W, 0.993PF, 3.5%THD(i)

More information

Report of Test LLIA A-R01*

Report of Test LLIA A-R01* Report of Test LLIA000849-002A-R01* *This test report supersedes test report LLIA000849-002A One Osram Optotronic OTi 30/120-277/1A0 DIM L LED driver. Total Light Output Luminaire Power Luminous Efficacy

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000762-003A Catalog Number: MLS3-I/D-HO/HO-K40-4-X-WSOP/LOH-X-XXX each. Two Osram Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous Efficacy

More information

T8 4ft 5000K EazyLux EZ8450D7R07

T8 4ft 5000K EazyLux EZ8450D7R07 PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08 Sample Tested T8 4ft 5000K EazyLux EZ8450D7R07 Prepared for: James Pan, Ph.D. Luxul Technology, Inc. 2905 Stender Way, Suite 22 Santa Clara, CA 95054 Phone:

More information

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH Report No: L101605127 Date: 12/8/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L101605127 Number Eight Lighting

More information

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063 Report No: L091706907 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L091706907 Issue Date: 10/16/2017 Report Prepared For: USTE, dba Vista Professional Outdoor Lighting 1625

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000676-006A Catalog Number: ML3WL-I/D-HO/HO-K40-4-X-LOH/LOH-X-X-UNV Two Osram Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous Efficacy Performance

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L111506001 Date: 11/25/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111506001 Report Prepared For: Osram Sylvania 200 Ballardvale

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L091502901 Date: 9/15/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091502901 Report Prepared For: Maxlite Model Number: WP-OPX120UT3-50BZZ

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB02540 PAGE: 1 OF 7 CATALOG NUMBER: VAN1LED12NW (SURFACE MOUNT - DROP LENS) LUMINAIRE: WHITE ALUMINUM SHEET METAL HOUSING, ONE WHITE CIRCUIT BOARD WITH 48 LEDS, FROSTED POLYCARBONATE DROP

More information

LLIA A-R02*

LLIA A-R02* Report of Test LLIA000762-001A-R02* *This test report supersedes test report LLIA000762-001A-R01 Catalog Number: MLS3-I-HO-K40-4-X-WSOP-X-XXX-X One Osram Optotronic OTi 30/0-277/1A0 DIM L LED driver. 0.0Vac,

More information

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description: Project Number Date 15.00487 3/26/2015 LAB 6 Test Sample Description Catalog Number: Description: P3408-0930K9 Close to Ceiling fixture Test Method: Preburn Time: Time To Stabilize: Total Operating Time:

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000676-003A Catalog Number: ML3WL-I/D-MO/MO-K40-4-X-LOH/LOH-X-X-UNV Two Osram Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous Efficacy Performance

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L12133401 Date: 12/18/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L12133401 FL/T8-32W/22W AC 410 Report Prepared

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000676-010A Catalog Number: ML5WL-I/D-HO/HO-K40-4-X-LOH/LOH-X-X-UNV Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous Efficacy Performance

More information

Soraa Internal Report: IES LM79 08

Soraa Internal Report: IES LM79 08 PRELIMINARY Soraa Internal Report: IES LM79 08 Test results reported for: Part Number: SM16-09-36D-930-03 Soraa MR16, GU5.3/12V, 3000K, 95CRI, 9W, 36degree Relevant Standards IES LM-79 ANSI C78.377 IES

More information

Calibration Due Date Chroma Programmable AC Source 61604

Calibration Due Date Chroma Programmable AC Source 61604 Test #: L12131802 Date: 12/17/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L12131802 FL/T8-32W/17W IU 350 Report Prepared

More information

Report of Test LLIA

Report of Test LLIA eport of Test LLIA000940-004 Catalog Number: F-FL/70/50K/T/BZ-67 90 white LEDs, one GL M2375.ev.A0 F516-170930018 LED board Data was measured in lateral increments as specified by IES LM-35-02, and half

More information

Soraa Internal Report: IES LM79-08

Soraa Internal Report: IES LM79-08 PRELIMINARY Soraa Internal Report: IES LM79-08 Test results reported for: Customer Reference P/N: SR111-18-08D-830-03 Manufacturing P/N: SR111-18-08D-830-03 Soraa AR111, G53/12V, 3000K, 80CRI, 18.5W, 8degree

More information

Report of Test LLIA A

Report of Test LLIA A eport of Test LLIA000930-009A Catalog Number: A300-I/D-MO/MO-K40-80--4-XX-LOH/LOH-XXXX-120 One Osram Optotronic OT50W/PG1400C/UNV/DIM/L LED driver 120.0Vac, 60.00Hz, 0.3027A, 36.14W, 0.995PF, 7.7%THD(i)

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000785-003 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 11408 lm 112.1 W 101.8 lm/w PREPARED FOR : Global Tech LED, 8901 Quality Road, Bonita Springs, FL

More information

Report of Test LLIA

Report of Test LLIA eport of Test LLIA000940-001 frosted plastic enclosure with clear lens sections in front of LEDs 18 white LEDs, one GL M1501.ev.A2 F516-170410002 LED board One International Power Product LP1020-36-C0300

More information

Report of Test LLIA

Report of Test LLIA Report of Test LLIA000953-001 Total Light Output Luminaire Power Luminous Efficacy Performance Summary 6608 lm 49.4 W 133.8 lm/w PREPARED FOR : Topaz Lighting Corp, 925 Waverly Avenue, Holtsville, NY 11742,

More information