1 Hydraulic Motor/Pump Fixed Displacement Catalogue HY /UK October 2006

2 Basic formulas for hydraulic motors Flow (q) D x n q = 1000 x η [l/min] v Torque (M) M = D x p x η hm 63 Power (P) q x p x η P = t [kw] 600 [Nm] D - displacement [cm 3 /rev] n - shaft speed [rpm] η v - volumetric efficiency p - differential pressure [bar] (between inlet and outlet) η hm - mechanical efficiency η t - overall efficiency (η t = η v x η hm ) Conversion factors 1 kg lb 1 N lbf 1 Nm lbf ft 1 bar psi 1 l US gallon 1 cm cu in 1 mm in 9 / 5 C F 1 kw hp

3 Content Content Page General information...4 F11 cross section...4 F12 cross sections...5 Specifications...6 Ordering codes F11-CETOP...7 F11-ISO...8 F11-SAE...9 F12-ISO...10 F12-Cartridge...11 F12-SAE...12 Preferred versions F11/F Technical information Bearing life...14 Efficiency...15 Noise level...15 Selfpriming speed and required inlet pressure...16 Installation dimensions F11-5 CETOP...17 F11-10 CETOP...18 F11-12 CETOP...19 F11-14 CETOP...20 F11-19 CETOP...21 F CETOP...22 F11-10 ISO...23 F11-12 ISO...24 F11-14 ISO...25 F11-10 SAE...26 F11-12 SAE...27 F11-14 SAE...28 F11-19 SAE...29 F SAE...30 F SAE...31 F12-30, -40, -60, -80, -90, -110 and -125 ISO F12-30, -40, -60, -80, -90, -110 and -125 Cartridge F12-30, -40, -60, -80, -90, -110 and -125 SAE 4 bolt flange F12-30, -40, and -60 SAE 2 bolt flange Technical information F11 saw motors...40 F11 fan motors...40 F12 integrated flushing valve...41 F12 accessory valve blocks...41 Type BT brake valve...42 Type SR pressure relief/make-up valve...42 Type SV pressure relief valve...43 Speed sensor...43 Installation information Direction of rotation...44 Hydraulic fluids...44 Operating temperature...44 Viscosity...45 Filtration...45 Case pressure...45 Case drain connections...46 Before start-up Parker Hannifin

4 General information F11 and F12 are bent axis, fixed displacement heavyduty motor/pump series. They can be used in numerous applications in both open and closed loop circuits. Series F11 is available in the following frame sizes and versions: - F11-5, -10, -12, -14, -19 and -150 with CETOP mounting flange and shaft end - F11-10, -12 and -14 with ISO flange and shaft - F11-10, -12, -14, -19, -150 and -250 with SAE flange and shaft Series F12 conforms to current ISO and SAE mounting flange and shaft end configurations. A very compact cartridge version is also available. Thanks to the unique spherical piston design, F11/F12 motors can be used at unusually high shaft speeds. Operating pressures to 480 bar provides for the high output power capability. The 40 angle between shaft and cylinder barrel allows for a very compact, lightweight motor/pump. The laminated piston ring offers important advantages such as low internal leakage and thermal shock resistance. The pump version has highly engineered valve plates for increased selfpriming speed and low noise, available with left and right hand rotation. The F11/F12 motors produce very high torque at startup as well as at low speeds. Our unique timing gear design synchronizes shaft and cylinder barrel, making the F11/F12 very tolerant to high 'G' forces and torsional vibrations. Heavy duty roller bearings permit substantial external axial and radial shaft loads. The F11's and F12's have a simple and straight-forward design with very few moving parts, making them very reliable motors/pumps. The unique piston locking, timing gear and bearing set-up as well as the limited number of parts add up to a very robust design with long service life and, above all, proven reliability. F11 cross section Barrel housing 2. Valve plate 3. Cylinder barrel 4. Guide spacer with O-rings 5. Timing gear 6. Roller bearing 7. Bearing housing 8. Shaft seal 9. Output/input shaft 10. Piston with laminated piston ring 10 4 Parker Hannifin

5 General information F12 cross sections F12-30, -40, -60, -80 and -90 (F12-60 shown) Legend: 1. Barrel housing 2. Valve plate 3. Cylinder barrel 4. Piston with piston ring 5. Timing gear 6. Tapered roller bearings 7. Bearing housing 8. Shaft seal 9. Output/input shaft 10. Port E (F and -125) 11. Needle bearings (F and -125) F and -125 (F shown) Parker Hannifin

6 Specifications Frame size F Displacement [cm 3 /rev] Operating pressure max intermittent 1) [bar] max continuous [bar] Motor operating speed [rpm] max intermittent 1) max continuous min continuous Max pump selfpriming speed 2) L or R function; max [rpm] Motor input flow max intermittent 1) [l/min] max continuous [l/min] Main circuit temp. 3), max [ C] min [ C] Mass moment of inertia (x10-3 ) [kg m 2 ] Weight [kg] Frame size F Displacement [cm 3 /rev] Operating pressure max intermittent 1) [bar] max continuous [bar] Motor operating speed [rpm] max intermittent 1) max continuous min continuous Max pump selfpriming speed 2) L or R function; max [rpm] Motor input flow max intermittent 1) [l/min] max continuous [l/min] Main circuit temp. 3), max [ C] min [ C] Mass moment of inertia (x10-3 ) [kg m 2 ] Weight [kg] ) Intermittent: max 6 seconds in any one minute. 2) Selfpriming speed valid at sea level. 3) See also installation information, operating temperature. 6 Parker Hannifin

7 Ordering codes F11 F11-CETOP Frame size Function Main ports Mounting flange Shaft seal Shaft Version number Option page 41 Option page 43 Frame size Code Displacem. (cm 3 /rev) Version number (assigned for special versions) Option None Frame size Code Function M Motor x x - - x x H Motor, high pressure x x x x x x Q Motor, quiet (x) (x) - - (x) (x) J Motor, clockwise rot'n 1) (x) (x) - - (x) (x) G Motor, counter clockw. 1) (x) (x) - - (x) (x) R Pump, clockwise rot'n (x) (x) (x) (x) (x) (x) L Pump, counter clockw. (x) (x) (x) (x) (x) (x) Frame size Code Shaft K Metric key x x x x x x D Spline, DIN 5480 (x) (x) (x) (x) (x) (x) Frame size Code Main ports B BSP threads x x x x x - R With anti-cavitation L valve; clockwise rot n 2) - (x) (x) (x) (x) - With anti-cavitation valve; counter clockw. 2) - (x) (x) (x) (x) - U SAE, UN threads (x) (x) - - (x) - F SAE 6000 psi flange 2) x Frame size Code Shaft seal N NBR 3), low pressure x x - - x x H NBR 3), high pressure (x) (x) - - (x) (x) E FPM 4), low pressure, high temperature (x) (x) (x) (x) (x) (x) V FPM 4), high pressure, high temperature - (x) x x (x) - Frame size Code Mounting flange C CETOP flange x x x x x x W Saw motor flange - (x) (x) (x) (x) - Frame size Code Option P Prepared for speed sensor - - x x x - x: Available (x): Optional : Not available 1) Internal drain 2) BSP threads 3) NBR - Nitrile rubber 4) FPM - Fluor rubber 7 Parker Hannifin

8 Ordering codes F11 F11-ISO Frame size Function Main ports Mounting flange Shaft seal Shaft Version number Option page 41 Option page 43 Frame size Code Displacem. (cm 3 /rev) Frame size Code Function M Motor x - - H Motor, high pressure x x x R Pump, clockwise rot'n (x) (x) (x) L Pump, counter clockw. (x) (x) (x) Version number (assigned for special versions) Frame size Code Shaft K Metric key x x x D Spline, DIN 5480 (x) (x) (x) Option None Frame size Code Main ports F Metric threads - x x B BSP x - - R With anti-cavitation valve; clockwise rot n (x) (x) (x) L With anti-cavitation valve; counter clockwise rot n" (x) (x) (x) Frame size Code Mounting flange I ISO flange x x x Frame size Code Shaft seal E FPM 1), low pressure, high temperature (x) (x) (x) V FPM 1), high pressure, high temperature x x x Frame size Code Option P Prepared for speed sensor - x x x: Available (x): Optional : Not available 1) FPM - Fluor rubber 8 Parker Hannifin

9 Ordering codes F11 F11-SAE Frame size Function Main ports Mounting flange Shaft seal Shaft Version number Option page 41 Option page 43 Frame size Code Displacem. (cm 3 /rev) Version number (assigned for special versions) Option None Frame size Code Function M Motor x - - x x - H Motor, high pressure x x x x x - Q Motor, quiet (x) - - (x) (x) x J Motor, clockwise rot'n 1) (x) - - (x) (x) - G Motor, counter clockw. 1) (x) - - (x) (x) - R Pump clockwise rot'n (x) (x) (x) (x) (x) (x) L Pump counter clockw. (x) (x) (x) (x) (x) (x) Frame size Code Shaft T SAE key - - x x x - S SAE spline (x) (x) (x) (x) (x) (x) K Metric key x x x F SAE spline (x) Frame size Code Main ports U SAE, UN threads x x x x - - B BSP threads (x) - - (x) - - F SAE 6000 psi flange 2) x x R With anti-cavitation valve; clockwise rot n (x) (x) (x) (x) - - L With anti-cavitation valve; counter clockwise rot n" (x) (x) (x) (x) - - Frame size Code Shaft seal N NBR 3), low pressure x - - x x - H NBR 3), high pressure (x) - - (x) (x) x E FPM 4), low pressure, high temperature (x) (x) (x) (x) (x) (x) V FPM 4), high pressure, high temperature (x) x x (x) - - Frame size Code Mounting flange S SAE flange x x x x x x Frame size Code Option P Prepared for speed sensor - x x x - - x: Available (x): Optional : Not available 1) Internal drain 2) Metric thread 3) NBR - Nitrile rubber 4) FPM - Fluor rubber 9 Parker Hannifin

10 Ordering codes F12 F12-ISO Frame size Function Main ports Mounting flange Shaft seal Shaft Version number Option page 41 Option page 43 Frame size Code Displacem. (cm 3 /rev) Version number (assigned for special versions) Frame size Code Shaft D DIN spline Optional (x) (x) (x) (x) (x) (x) (x) Z " " Optional (x) (x) (x) (x) (x) (x) (x) K Metric key Standard x x x x x x x P " " Optional (x) Frame size Code Function M Motor x x x x x x x Pump: L counter clockw. (x) (x) (x) (x) (x) (x) (x) R clockwise (x) (x) (x) (x) (x) (x) (x) Frame size Code Option L01 Integr. flushing valve x x x x x - 3) - 3) Frame size Code Main ports F SAE 6000 psi flange x x x x x x x R With anti-cavitation valve; clockwise rot n (x) L With anti-cavitation valve; counter clockwise rot n" (x) Frame size Code Mounting flange I ISO flange x x x x x x x Frame size Code Option P Prepared for speed sensor x x x x x x x Frame size Code Shaft seal H NBR 1), high pressure x x x x x x x N NBR 1), low pressure (x) (x) (x) (x) (x) (x) (x) V FPM 2), high temperature, (x) (x) (x) (x) (x) (x) (x) high pressure E FPM 2), high temperature, (x) (x) (x) (x) (x) (x) (x) low pressure x: Available (x): Optional : Not available 1) NBR - Nitrile rubber 2) FPM - Fluor rubber 3) F and -125: Accessory valve block (page 41) 10 Parker Hannifin

11 Ordering codes F12 Frame size F12-Cartridge Function Main ports Mounting flange Shaft seal Shaft Version number Option page 41 Option page 43 Frame size Code Displacem. (cm 3 /rev) Version number (assigned for special versions) Frame size Code Shaft C DIN spline Standard x x x x x x x K Metric key Optional (x) - (x) (x) (x) - - X " " Optional - (x) Frame size Code Function M Motor x x x x x x x Frame size Code Option L01 Integr. flushing valve x x x x x - 3) - 3) Frame size Code Main ports F SAE 6000 psi flange x x x x x x x R With anti-cavitation valve; clockwise rot n (x) L With anti-cavitation valve; counter clockwise rot n" (x) Frame size Code Mounting flange C Cartridge x x x x x x x x: Available (x): Optional : Not available 1) NBR - Nitrile rubber 2) FPM - Fluor rubber 3) F and -125: Accessory valve block (page 41) Frame size Code Option P Prepared for speed sensor x x x x x x x Frame size Code Shaft seal H NBR 1), high pressure x x x x x x x N NBR 1), low pressure (x) (x) (x) (x) (x) (x) (x) V FPM 2), high temperature, (x) (x) (x) (x) (x) (x) (x) high pressure E FPM 2), high temperature, (x) (x) (x) (x) (x) (x) (x) low pressure 11 Parker Hannifin

12 Ordering codes F12 F12-SAE Frame size Function Main ports Mounting flange Shaft seal Shaft Version number Option page 41 Option page 43 Frame size Code Displacem. (cm 3 /rev) Frame size Code Function M Motor x x x x x x x Pump: L counter clockw. (x) (x) (x) (x) (x) (x) (x) R clockwise (x) (x) (x) (x) (x) (x) (x) Version number (assigned for special versions) Frame size Code Shaft S SAE spline Optional (x) (x) (x) (x) (x) (x) (x) U " " Optional (x) (x) - - T SAE key Standard x x x x x x x Frame size Code Option L01 Integr. flushing valve x x x x x - 3) - 3) Frame size Code Main ports S SAE 6000 psi flange x x x x x x x U SAE, UN threads (x) (x) (x) (x) (x) (x) (x) R With anti-cavitation valve; clockwise rot n (x) L With anti-cavitation valve; counter clockwise rot n" (x) Frame size Code Mounting flange S SAE 4 bolt x x x x x x x T SAE 2 bolt x x x Frame size Code Option P Prepared for speed sensor x x x x x x x Frame size Code Shaft seal H NBR 1), high pressure x x x x x x x N NBR 1), low pressure (x) (x) (x) (x) (x) (x) (x) V FPM 2), high temperature, (x) (x) (x) (x) (x) (x) (x) high pressure E FPM 2), high temperature, (x) (x) (x) (x) (x) (x) (x) low pressure x: Available (x): Optional : Not available 1) NBR - Nitrile rubber 2) FPM - Fluor rubber 3) F and -125: Accessory valve block (page 41) 12 Parker Hannifin

13 Ordering codes Preferred versions F11/F12 F11 Ordering Codes Part number F MB-CN-K F MB-CH-K F HU-CH-K F MB-CN-K F MB-CH-K F HU-CH-K F HB-CV-K F HB-CE-K F HB-CE-K F HB-CV-K F MB-CN-K F MB-CH-K F MF-CN-K F MF-CH-K F HF-SH-S F QF-SH-F F QF-SH-K F12 Ordering Codes Part number F MF-IH-D F MF-IH-K F MS-SH-S F MS-TH-S F MF-IH-D F MF-IH-K F MS-SH-S F MS-SH-T F MS-TH-S F MF-IH-D F MF-IH-K F MS-SH-S F MS-TH-S F MF-IH-D F MF-IH-K F MS-SH-S F MF-IH-D F MF-IH-K F MS-SH-S F MF-IH-D F MF-IH-K F MS-SH-S F MF-IH-D F MF-IH-K F MS-SH-S Parker Hannifin

14 Technical information Bearing life General information Bearing life can be calculated for that part of the load/ life curve (shown below) that is designated 'Bearing fatigue'. 'Rotating group fatigue and wear' and 'Other' caused by material fatigue, fluid contamination, etc. should also be taken into consideration when estimating the service life of a motor/pump in a specific application. Bearing life calculations are mainly used when comparing different frame sizes. Bearing life, designated B 10 (or L 10 ), is dependent of system pressure, operating speed, external shaft loads, fluid viscosity in the case, and fluid contamination level. The B 10 value means that 90% of the bearings survive, at a minimum, the number of hours calculated. Statistically, 50% of the bearings will survive at least five times the B 10 life. Life expectancy (logarithmic scale) Other causes Bearing fatigue Required information When requesting a bearing life calculation from Parker Hannifin (Pumps and Motor Division), the following information (where applicable) should be provided: - A short presentation of the application - F11 or F12 size and version - Duty cycle (pressure and speed versus time at given displacements) - Low system pressure - Case fluid viscosity - Life probability (B 10, B 20, etc.) - Operating mode (pump or motor) - Direction of rotation (L or R) - External shaft loads (Forces, Gear, Belt, Cardan or none) For forces please provide: - Axial load, Fixed radial load, Bending moment, Rotating radial load and distance flange to radial load. For Gear please provide: - Pitch diameter, Pressure angle, Spiral angle, Distance flange gearwheel (mid) and Gearwheel spiral direction (R or L). For Belt please provide: - Pretension, Coefficient of friction, Angle of contact, Distance flange pulley (mid) and Diameter pulley. For Cardan please provide: - Shaft angle, Distance flange first joint and distance between joints - Angle of attack (α) as defined below Rotating group fatigue and wear System pressure Bearing_life_DE.eps Hydraulic unit life versus system pressure. Bearing life calculation An application is usually governed by a certain duty or work cycle where pressure and speed vary with time during the cycle. In addition, bearing life depends on external shaft forces, fluid viscosity in the case and fluid conta-mination. Parker Hannifin has a computer program for calculating bearing life and will assist in determining F11 or F12 motor/pump life in a specific application. F F α The direction (a) of the F12_shaft_loads.EPS radial is positive in the direction of rotation as shown. To obtain maximum bearing life, the radial load should, in most cases, be located approximately at 170 (motor; R.H. rot'n) or 190 (pump; R.H rot'n). 14 Parker Hannifin

15 Technical information Efficiency Because of its high overall efficiency, driving a motor/ pump from series F11/F12 requires less fuel or electric power. Also, it allows the use of a small reservoir and heat exchanger, which in turn reduce cost, weight, and installation size. The diagrams to the right shows volumetric and mechanical efficiencies of an F Contact Parker Hannifin for efficiency information on a particular F11/F12 frame size that is being considered. 100% 90% 80% F12-30 (motor) 210 bar Volymetric efficiency. 420 bar Speed [rpm] 100% 90% 80% F12-30 (motor) 210 bar 420 bar Noise level feature low noise levels from low to high speeds and pressures. As an example, the diagram to the right shows the noise level of an F The noise level is measured in a semi-anechoic room, 1 m behind the unit. The noise level for a particular motor/pump may vary ±2 db(a) compared to what is shown in the diagram. NOTE: Noise information for F11/F12 frame sizes are available from Parker Hannifin Mechanical efficiency. Noise level [db(a)] rpm 3500 rpm 2000 rpm F12-30 (M-, L- or R funktion ) Speed [rpm] Efficiency_F12_DE.eps Pressure [bar] 15 Parker Hannifin

16 Technical information Selfpriming speed and required inlet pressure Series F11 In pump applications, the F11 with function L (counter clockwise rotation) or R (clockwise rotation) is normally used. The L and R (pump) provide the highest selfpriming speeds (see table) as well as the lowest noise level. The M (motor) function can also be used as a pump, in either direction, but at a lower selfpriming speed. Operating above the selfpriming speed (refer to Diagram 1) requires increased inlet pressure. As an example, at least 1.0 bar is needed when operating the F11-19-M as a pump at 3500 rpm. An F11 used as a motor (e.g. in a hydrostatic transmission), may sometimes operate as a pump at speeds above the selfpriming speed; this requires additional inlet pressure. Insufficient inlet pressure can cause pump cavitation resulting in greatly increased pump noise and deteriorating performance. Function L or R M H F F F F F F F Inlet pressure gauge Series F12 When operating the F12 as a pump (with L or R valve plate) above the selfpriming speed, the inlet must be pressurized. Increased noise and deteriorating performance may otherwise be experienced. Diagrams 2 and 3 show required pump inlet pressure vs. shaft speed. The F12 motor (type M valve plate) sometimes operates as a pump e.g. when used in a propel transmission and the vehicle is going downhill. Minimum required inlet pressure versus shaft speed is shown in the diagrams. Inlet pressure [bar] 2,0 1,5 1,0 0,5 0 Inlet pressure [bar] 2,0 1,5 1,0 0,5 0 F ,15 bar vacuum -0, Speed [rpm] Diagram 2. Min. required pump (F12-L or -R) inlet press. Inlet pressure [bar] F ,0 1,5 1,0 F11-19 F12-L or -R F12-M M L, R 0,15 bar vacuum -0, Speed [rpm] Diagram 1. Min required F11_inlet_pressure.eps (F11-19). 0,5 NOTE: Diagrams 1, 2 and 3 are valid at sea level. 0 0,15 bar vacuum -0, Speed [rpm] Diagram 3. Min. F12_inlet_pressure.eps required motor (F12-M) pressure. 16 Parker Hannifin

17 Installation dimensions F11-5 (CETOP versions) 53 Ø11 (x2) max 100 Ø127 max Type C mounting flange max Approx. center of gravity Drain port D (BSP1/4 ) Main port A (BSP 1/2 ) 38 Main port B (BSP 1/2 ) 134 max Drain port C (BSP1/4 ) Flange C Key 6x6x30 8 R 0.7 R 0.5 Type K key shaft 5 Ø18 (+0.008/-0.003) 12 min M6 Ø Ø80 (+0/-0.046) 20 W18x1,25x13x9g Type D spline shaft (DIN 5480) 17 Parker Hannifin

18 Installation dimensions F11-10 (CETOP versions) 57 Ø13 (x2) max 125 Ø152 max Type C mounting flange max Approx. center of gravity Drain port D (BSP3/8 ) Main port A (BSP 3/4 ) 46 Main port B (BSP 3/4 ) 156 max Drain port C (BSP3/8 ) Flange C Key 6x6x35 8 R 0.7 R 0.5 Type K key shaft Ø23 min 7 Ø20 (+0.009/-0.004) 12 min M Ø100 (+0/-0.004) 9 22 W20x1,25x14x9g Type D spline shaft (DIN 5480) 18 Parker Hannifin

19 Installation dimensions F11-12 (CETOP versions) Anticavitation valve (LH or RH optional; right hand shown) (59) B A CCW CW 40 (x4) 116 max Ø13 (x2) max Main port B (BSP 3/4 ) (32) /-1 (45) Speed sensor (optional) 25 Main port A (BSP 3/4 ) Drain port D (BSP3/8 ) max (149) (x2) Flange C Key 6x6x35 Type K key shaft 22 (Ø19.75) 7 Ø20 (+0.009/-0.004) Ø23 Spline shaft D W20x1.25x14x9g; DIN M6x12 min Ø100 (+0/-0.054) 19 Parker Hannifin

20 Installation dimensions F11-14 (CETOP versions) Anticavitation valve (left or right hand optional; right hand shown) 59 B A CCW CW Ø13 (x2) 39 (x4) Type C mounting flange Main port A (BSP 3/4 ) 102 Main port B (BSP 3/4 ) Speed sensor (optional) Drain port D (BSP3/8 ) max Drain port C (BSP3/8 ) Flange C Type K key shaft Ø27 R 0.7 Key 8x7x35 8 Ø25 (+0.009/-0.004) 26 Ø24.75 Shaft D W 25x1.25x18x9g DIN Ø100 (+0/-0.004) M8x16 R 0.5 F11_14_CETOP.eps 20 Parker Hannifin

21 Installation dimensions F11-19 (CETOP version) 87 Ø14 (x2) Ø172 max Type C mounting flange max 11 Approx. center of gravity Main port A (BSP 3/4 ) 54 Main port B (BSP 3/4 ) 165 max Drain port D (BSP3/8 ) 29 Drain port C (BSP3/8 ) Flange C Key 8x7x35 R 1.0 max Ø28.3 min Ø112 (+0/-0.054) R 1.2 max min Type K key shaft M8 Ø25 (+0.009/-0.004) W25x1,25x18x9g Type D spline shaft (DIN 5480) F11-19_CETOP_install.eps 21 Parker Hannifin

22 Installation dimensions F (CETOP version) Ø250 Ø22 (x4) max Type C mounting flange 222 max Approx. center of gravity Main port A* (1 1 / 2 ") 36.5 M16(x8) Main port B* (1 1 / 2 ") Drain port D (BSP 3 / 4 ") Drain port C (BSP 3 / 4 ") Type C flange R 0.7 Ø57 min Ø200 (+0/-0.072) Key 14x9x70 R Type K key shaft M16 thread Ø50 (+0.018/+0.002) M16 thread 30 * 6000 psi flange (SAE J581c) W45x2x21x9g Type D spline shaft (DIN 5480) 22 Parker Hannifin

23 Installation dimensions F11-10 (ISO versions) 10.5 (x4) B A ccw cw Ø9 (x4) R 4.5 (x4) (Ø103) Main port A (BSP 3/4 ) Main port B (BSP 3/4 ) 95 (max) 46 B Drain port (BSP3/8 ) max Flange I (ISO 3019/2) Type K 6 key shaft Ø20 (+0.009/-0.004) Ø23 Key 6x6x35 Spline shaft D W20x1.25x14x9g; DIN R 0.5 max M6x12 min 22.5 Ø80 +0/ F11_010_ISO_ny.ai 23 Parker Hannifin

24 Installation dimensions F11-12 (ISO versions) Anticavitation valve (LH or RH optional; right hand shown) 10.5 (x4) 59 B A ccw cw Ø9 (x4) R 4.5 (x4) (Ø103) Main port A M26x deep min Speed sensor ISO (optional) Main port B M26x deep min ISO max Drain port M16x deep min ISO Flange I (ISO 3019/2) R Type K key shaft Key 6x6x35 Ø23 6 Ø20 (+0.009/-0.004) 22.5 Ø80 +0/ M6x12 min 24 Parker Hannifin

25 Installation dimensions F11-14 (ISO versions) Ø9 (x4) 10.5 (x4) Ø9 (x4) B A CCW CW Ø103) Type I mounting flange (ISO 3019/2) Speed sensor (optional) Main port A M26x deep min ISO Main port B M26x deep min ISO Drain port D M16x1.5 (depth 12; ISO ) max 21 Flange I (ISO 3019/2) Drain port C M16x1.5 (depth 12; ISO ) Type K key shaft Key 8x7x35 8 Ø27 28 Ø25 (+0.009/-0.004) Ø24.75 W25x1.25x18x9g Type D spline shaft (DIN 5480) 6.7 R 0.5 max M8x16 28 Ø80 (+0/-0.046) 25 Parker Hannifin

26 Installation dimensions F11-10 (SAE versions) R60 (x2) 29 (x4) R14 (x4) CCW CW Ø14.4 (x2) 122 max (max) Main port A 1 1 / UN O-ring boss; SAE J514d 94 max 46 Main port B 1 1 / UN O-ring boss; SAE J514d 20 Drain port 9 / UNF O-ring boss; SAE J514d max (x2) 8 R Ø23 Flange S size SAE B SAE J744c Type K key shaft Key 6x6x35 Ø20 (+0.009/-0.004) Ø Type S spline shaft SAE B, 13T, 16/32 DP (SAE J498b, class 1; 30 involute spline; flat root, side fit) 16 min M6x Ø101.6 (+0/-0.05) Parker Hannifin

27 Installation dimensions F11-12 (SAE versions) Anticavitation valve (LH or RH optional; right hand shown) R 60 (x2) 58 B A ccw cw max R 14 (x4) 29 (x4) Ø14.4 (x2) 122 Main port A 1 1 / UN O-ring boss; SAE J514d Main port B 1 1 / UN O-ring boss; SAE J514d Speed sensor (optional) Drain port 9 / UNF O-ring boss; SAE J514d max 17 (x2) Ø24 (x2) Key 6x6x Ø R Flange S size SAE B SAE J744c Type K key shaft Ø23 6 Ø20 (+0.009/-0.004) Type S spline shaft SAE B, 13T, 16/32 DP (SAE J498b, class 1; 30 involute spline; flat root, side fit) M6x12 min 22.5 Ø55 Ø101.6 (+0/-0.05) 27 Parker Hannifin

28 Installation dimensions F11-14 (SAE versions) R 260 (x2) 120 B A CCW CW R 14 (x4) 29 (x4) Ø14.5 (x2) (max) Type S mounting flange SAE 'B' ( SAE J744c) Speed sensor (optional) Main port A 1 1 / UN O-ring boss; SAE J514d Main port B 1 1 / UN O-ring boss; SAE J514d 25 Drain port D 9 / UNF O-ring boss; SAE J514d max 17 (x2) Ø24 (x2) Drain port C 9 / UNF O-ring boss; SAE J514d (8) 33 R 0.5 Type T key shaft Size 25-1 (B B) (SAE J744c) Ø27 Key 6.35x6.35x Ø25.4 (+0/-0.05) 24 Type S spline shaft SAE B, 13T, 16/32 DP (SAE J498b, class 1; 30 involute spline; flat root, side fit) 28.1 Ø80 Ø / / UNF-2B (depth 16) 28 Parker Hannifin

29 Installation dimensions F11-19 (SAE version) Ø14.4 (x2) R Ø176 max Type S mounting flange SAE B (SAE J744c) max 11 Approx. center of gravity Main port A* (1 1 / 16 "-12) 54 Main port B* (1 1 / 16 "-12) Drain port D* ( 9 / 16 "-18) max Drain port C* ( 9 / 16 "-18) 38.1 Flange S Key 6.35x6.35x31.8 Ø25 (+0.400/+0.350) Type T key shaft SAE B-B (SAE J744c) 28.3 min R 1.0 R min 5 /16 "-24 UNF-2b 28.1 Ø101 (+0.600/+0.550) 8 * O-ring ports according to SAE J514d 33 SAE 'B' (13T, 16/32 DP; Type S spline shaft (SAE J498b) 29 Parker Hannifin

30 Installation dimensions F (SAE version) Ø21 (x4) max Type S mounting flange SAE D (SAE J744c) 222 max Approx. center of gravity Drain port D (BSP 3 / 4 ") 206 Main port A* (1 1 / 2 ") M16(x8) Main port B* (1 1 / 2 ") 79.4 Drain port C (BSP 3 / 4 ") R 0.8 R 1.0 Type S flange 30 Type T key shaft SAE D (SAE J744c) Ø57 min Ø152 (+0.400/+0.350) Key 11.11x11.11x54 5/8-18 UNF 49.3 Ø44 (+0.450/+0.400) 8 * 6000 psi flange (SAE J581c) 66.7 SAE 'D'; 13T, 8/16 DP; class 1, flat root, side fit Type S spline shaft (SAE J498b) F1_150_SAE_install.eps 30 Parker Hannifin

31 Installation dimensions F (SAE version) 200 max Ø21 (x4) 200 max Type S mounting flange SAE D (SAE J744c) M16x35 (x8) Main port A* (1 1 / 2 ") 36.5 Main port B* (1 1 / 2 ") Approx. center of gravity Drain port D (BSP 3 / 4 ") 141 Ø39 (x2) Drain port C (BSP 3 / 4 ") R 0.7 Key 14x9x R 0.8 Type K key shaft (metric; not SAE) Ø50 (+0.018/+0.002) M16x31 (thread) 53.5 Ø57 min 7.9 Ø152 (+0.400/+0.350) 35 SAE F; 15T, 8/16 DP; class 1, flat root, side fit Optional: Type S spline shaft: 13T 8/16 DP * 6000 psi flange (SAE J518c) 66.7 Type F spline shaft (SAE J498b) 31 Parker Hannifin

32 Installation dimensions F12-30, -40, -60, -80, -90, -110 and -125 (ISO versions) C1 A1 T3 Flushing valve (optional) A2 A1 B1 Type I mounting flange (ISO 3019/2) C2 B2 Port D ØD1 (x4) F12-80 shown Port A Port E (third drain port) F and -125 barrel housing (ISO /cartridge version) C3 A3 B3 Port B K3 G2 Port C 1) N2 G3 H2 (±0,5) K2 Speed sensor (optional) P2 H3 L3 J2 Type K (P) Key shaft 1) Inspection/ drain port L2 D2 M2 ØE2 ØF2 (tol. h8) Type I flange S2 2) Q2 R2 See table 2) Type Z has no thread Type D (Z) spline shaft J3 F3 D3 ØE3 (Tol. k6) 32 Parker Hannifin

33 Installation dimensions Dim. F12-30 F12-40 F12-60 F12-80 F F12-90 F A B C D A B C D E F G H J2 1) J2 2) K L M N P Q R2 3) R2 4) S2 3) M12 M12 M12 M16 M16 x24 x24 x28 x36 x36 S2 4 ) - M12 - M12 - x24 x28 A B C D3 M12 M12 M12 M16 M16 E F G H J K L T ) Key shaft type K 3) Spline shaft type D 2) Key shaft type P 4) Spline shaft type Z Ports F12-30 F12-40 F12-60 F12-80 F F12-90 F A, B 3 / 4 " 3 / 4 " 3 / 4 " 1" 1 1 / 4 " size Screw M10 M10 M10 M12 M14 thread 1) x20 x20 x20 x20 x26 C M22 M22 M22 M22 M22 thread 2) x1.5 x1.5 x1.5 x1.5 x1.5 D M18 M18 M22 M22 M22 thread 2) x1.5 x1.5 x1.5 x1.5 x1.5 E M22 thread x1.5 A, B: ISO ) Metric thread x depth in mm 2) Metric thread x pitch in mm. Spline shaft (DIN 5480) Key shaft Type D (standard) Type K (standard) Type Z (optional) F12-30 W30x2x14x9g W25x1.25x18x9g -40 W32x2x14x9g W30x2x14x9g -60 W35x2x16x9g W32x2x14x9g -80 W40x2x18x9g W35x2x16x9g -90 W40x2x18x9g W35x2x16x9g -110 W45x2x21x9g W40x2x21x9g -125 W45x2x21x9g W40x2x21x9g Type P (optional) F12-30 Ø30 Ø25-40 Ø Ø Ø Ø Ø Ø45 - = Max 350 bar operating pressure 33 Parker Hannifin

34 Installation dimensions F12-30, -40, -60, -80, -90, -110 and -125 (Cartridge versions) F12-80 shown C4 E4 A4 T6 40 (-30, -40, -60, -110, -125) 43 (-80, -90) Flushing valve (optional) ØD4 (x2) A5 B4 Type C mounting flange C5 B5 Port D Port E (third drain port) F and -125 barrel housing (ISO /cartridge version) Port A C6 A6 B6 Port B G5 Port C 1) K5 Speed sensor (optional) N5 Q6 K6 L6 G6 H5 (±0,2) S5 T5 P5 R6 O-ring (included) H6 R5 1) Inspection/ drain port Q5 ØV5 ØF5 (Tol. h8) Type C spline shaft See table J5 L5 D5 M5 ØE5 (Tol. k6) Type K (X) key shaft ØM6 ØN6 ØP6 34 Parker Hannifin

35 Installation dimensions Dim. F12-30 F12-40 F12-60 F12-80 F F12-90 F A B C D E A B C D ) 10 2) E ) 35 2) F G H J K L M N P Q R S T V A B C G H K L M N P Q R T ) Key shaft type K 2) Key shaft type X (opt.). Ports F12-30 F12-40 F12-60 F12-80 F F12-90 F A, B size 3 / 4 " 3 / 4 " 3 / 4 " 1" 1 1 / 4 " Screw M10 M10 M10 M12 M14 thread x20 x20 x20 x22 x26 C M14 M14 M14 M14 M14 thread x1.5 x1.5 x1.5 x1.5 x1.5 D, E M18 M18 M22 M22 M22 thread x1.5 x1.5 x1.5 x1.5 x1.5 A, B: ISO 6162 Spline shaft (DIN 5480) Type C (standard) F12-30 W30x2x14x9g -40 W30x2x14x9g -60 W30x2x14x9g -80 W40x2x18x9g -90 W40x2x18x9g -110 W40x2x18x9g -125 W40x2x18x9g Key shaft Type K (std) O-ring dimensions F x x x x x x x4 Type X (opt.) F12-30 Ø30-40 Ø35-60 Ø35-80 Ø40-90 Ø40 35 Parker Hannifin

36 Installation dimensions F12-30, -40, -60, -80, -90, -110 and -125 (SAE versions with 4 bolt flange) C7 A7 T9 Flushing valve (optional) A8 A7 B7 Type S (SAE 4 bolt) mounting flange C8 B8 Port D ØD7 (x4) Shown: F12-80 with 4 bolt flange Port A Port E (third drain port) F and -125 barrel housing (SAE version) C9 A9 B9 Port B K9 G8 Port C 1) N8 G9 K8 Speed sensor (optional) L9 H8 J8 Type T key shaft 1) Inspection/ drain port D8 ØE8 ØF8 L8 M8 R8 Q8 See table Type S (U) spline shaft H9 Type S flange J9 D9 ØE9 F9 F12_80_SAE_4bolt_inst.eps 36 Parker Hannifin

37 Installation dimensions Dim. F12-30 F12-40 F12-60 F12-80 F F12-90 F A B C D A B C D E F / / / / / G H J K L M N Q8 1) Q8 2) R8 1) R8 2) A B C D9* 5 / 16 "-24 3 / 8 "-24 3 / 8 "-24 1 / 2 "-20 5 / 8 "-18 E / 31.75/ 31.75/ 38.10/ 44.45/ F G H J K L T * UNF-2B thread 1) Spline shaft type S 2) Spline shaft type U Main ports A and B, type U (optional) F / 16 " - 12 UN F / 16 " - 12 UN F / 8 " - 12 UN F / 8 " - 12 UN O-ring ports according to SAE J514d Ports F12-30 F12-40 F12-60 F12-80 F F12-90 F A, B size 3 / 4 " 3 / 4 " 3 / 4 " 1" 1 1 / 4 " Screw 3 / 8 "-16 3 / 8 "-16 3 / 8 "-16 7 / 16 "-14 1 / 2 "-13 thread 3) x22 x20 x22 x27 x25 C thread 7 / 8 "-14 7 / 8 "-14 7 / 8 "-14 7 / 8 " / 16 "-12 D thread 3 / 4 "-16 3 / 4 "-16 7 / 8 "-14 7 / 8 " / 16 "-12 E thread / 16 "-12 A, B: ISO 6162 C, D, E: O-ring boss (SAE J514) 3) UN thread x depth in mm. Mounting flange (SAE J744) S (standard) X (optional) F12-30 SAE 'B', 4 bolt SAE 'C', " SAE 'C', " SAE 'C', " SAE D, 4 bolt -90 SAE 'C', " SAE D, 4 bolt -110 SAE 'D', " SAE 'D', " - Spline shaft (SAE J498b, class 1, flat root, side fit) S (standard) U (opt.) X (optional) F12-30 SAE 'B' T, 16/32 DP -40 SAE 'C' 14T, /24 DP -60 SAE 'C' 14T, /24 DP -80 SAE 'C-C' SAE 'C' SAE 'D' 17T, 12/24 DP 14T,12/24DP 13T, 8/16 DP -90 SAE 'C-C' SAE 'C' SAE 'D' 17T, 12/24 DP 14T,12/24DP 13T, 8/16 DP -110 SAE 'D' T, 8/16 DP -125 SAE 'D' T, 8/16 DP = Max 350 bar operating pressure. Key shaft (SAE J744) T (standard) X (optional) F12-30 SAE 'B-B' (Ø25.4 mm/1") SAE 'C' - (Ø31.75 mm/1 1 / 4 ") -60 SAE 'C' - (Ø31.75 mm/1 1 / 4 ") -80 SAE 'C-C' SAE D (Ø38.1 mm/1 1 / 2 ") (Ø44.45 mm/1 3 / 4 ") -90 SAE 'C-C' SAE D (Ø38.1 mm/1 1 / 2 ") (Ø44.45 mm/1 3 / 4 ") -110 SAE 'D' (Ø44.45 mm/1 3 / 4 ") SAE 'D' - (Ø44.45 mm/1 3 / 4 ") 37 Parker Hannifin

38 Installation dimensions F12-30, -40, and -60 (SAE versions with 2 bolt flange) C10 R E10 R F10 ØD10 (x2) Flushing valve (optional) G11 A10 B10 Type T (SAE 2 bolt) mounting flange A11 B11 C11 Port D Shown: F12-60 with 2 bolt flange A12 B12 C12 Port A Port B K12 Port C 1) N11 G12 Speed sensor K11(optional) H12 L12 H11 J11 Type T key shaft 1) Inspection/ drain port D11 ØE11 ØF11 L11 R11 M11 Q11 See table Type T flange Type S spline shaft J12 F12 D12 ØE12 F12_60_SAE_2bolt_inst.eps 38 Parker Hannifin

39 Installation dimensions Dim. F12-30 F12-40 F12-60 A B C D E F A B C D E F / / / G H J K L M N Q R A B C D12 1) 5 / 16 "-24 3 / 8 "-24 3 / 8 "-24 E / 31.75/ 31.75/ F G H J K L Ports F12-30 F12-40 F12-60 A, B size ( 3 / 4 ") ( 3 / 4 ") ( 3 / 4 ") Screw 3 / 8 "-16 3 / 8 "-16 3 / 8 "-16 thread 2) x22 x20 x22 C 3 / 4 "-16 3 / 4 "-16 7 / 8 "-14 thread D 3 / 4 "-16 3 / 4 "-16 7 / 8 "-14 thread A, B (main ports): SAE J518c (6000 psi) C, D (drain ports): O-ring boss (SAE J514) 2) UN thread Main ports A and B, type U (optional) F / 16 " - 12 UN / 16 " - 12 UN / 16 " - 12 UN O-ring ports according to SAE J514d = Max 350 bar operating pressure. Mounting flange T (SAE J744) F12-30 SAE 'B', 2 bolt -40 SAE 'C', 2 bolt -60 SAE 'C', 2 bolt Spline shaft S (SAE J498b, class 1, flat root, side fit) F12-30 SAE 'B' 13 T; 16/32 DP -40 SAE 'C' 14 T; 12/24 DP -60 SAE 'C' 14 T; 12/24 DP 1) UNF-2B thread Key shaft T (SAE J744) F12-30 SAE 'B-B' Ø25.4 mm/1" -40 SAE 'C' Ø31.75 mm/1 1 / 4 " -60 SAE 'C' Ø31.75 mm/1 1 / 4 " 39 Parker Hannifin

40 Technical information F11 saw motors Series F11 motors have proven suitable for demanding applications such as chain saws. Primarily due to the 40 bent-axis design, spherical pistons (with laminated piston rings) and gear synchronization, very high speeds are permissible. Not even low temperatures at start-up affect reliability. To further enhance the saw function and, at the same time, reduce weight, cost and installation dimensions, a specific saw motor has been developed (frame sizes -10, -14 and -19; refer to the illustration to the right) which is specifically dedicated to bar saws. The motor allows the saw bar bearings to be mounted directly on the motor housing, and the sprocket installs on the motor shaft without additional bearings. For more detailed information (available versions, ordering codes, installation dimensions, etc.), refer to 'F11 Saw Motors' (catalogue HY ). F11 with built-in make-up valve Saw bar supported directly on the motor flange Feed cylinder Chain sprocket mounted directly on the shaft Saw chain Protective cover Saw bar Chain saw installation (example; F11-10 shown) F11 and F12 fan motors Frame sizes -10, -12, -14, -19 (F11) and -30 (F12) are also available as 'fan motors' with a built-in check valve (refer to the schematic below) and CETOP mounting flange. Just like the saw motor, the fan motor can be operated at very high speeds without reliability problems. The fan is usually installed directly on the motor shaft without additional bearing support. Additional information (available versions, ordering codes, installation dimensions, etc.) is available in publication 'F11, F12 Fan Motors' (catalogue HY /UK). Port A Port B Built -in make-up valve Alternative drain port D Main port B Port G Type C mounting flange (CETOP) Port C/D Port G Only for F11-10, -19 (for make-up flow if required) Fan motor Fan_motor_schem.eps schematic (left hand rotation shown). Main port A Drain port C Type K key shaft (CETOP) Fan motor (F11-10 shown). F11_fan_motor.eps 40 Parker Hannifin

41 Technical information F12 integrated flushing valve (F12-30, -40, -60, -80, and -90) Series F12 (except F and F12-125; refer to the FV13 flushing valve block below) is available with an integrated flushing valve which provides the rotating parts with an additional cooling flow, required when operating at high speeds and power levels. In a hydrostatic transmission, the valve also ensures that part of the main circuit fluid is being removed and replaced by cool, filtered fluid from the charge pump. The flow is limited by a suitably sized nozzle that installes below a plug in the motor port flange. Built-in flushing valve Nozzle (optional) NOTE: Ordering code, available nozzles and other information is provided in publication Mobile motor/pump accessories (catalogue HY /UK). Integrated flushing valve (F12-30, -40, -60, -80, -90) Nozzle (optional) Port A Port B F12_FV_schem.eps F12 accessory valve blocks Type FV13 flushing valve (for F and F12-125) A separate flushing valve block is available for the F and F It has the same function as the integrated valve for the other F12 frame sizes (above). The valve block mounts between the motor port flange and the split flanges as shown to the right. An optional nozzle can be installed in the valve block drain port. Ordering code: FV13 NOTE: Additional information is available in publication Mobile motor/pump accessories (catalogue HY /UK). Nozzle (optional) FV13 flushing valve block F12_110_FV_install.eps Nozzle (optional) Port A Port B FV13 flushing valve block 41 Parker Hannifin

42 Technical information Type BT brake valve When a motor (in an open loop system) is used in a hydrostatic vehicle transmission, the motor may operate faster than what corresponds to the available pump flow (e.g. in a steep downhill); this can lead to motor cavitation and loss of braking power. The BT brake valve prevents cavitation by throttling the return flow from the motor as soon as the pressure level in the inlet port decreases to approximately 35 bar. At the same time, motor braking is provided when the pump flow decreases or is shut off. The BT brake valve can be supplied with various optional functions such as a mechanical brake release valve and a flushing valve. The valve block is very compact and installs between the motor port flange and the split flanges (refer to the illustration). The BT valve block is available in two sizes: - BT21 ( 3 / 4 ") for F12-30, -40, BT22 (1") for F12-80, -90 BT brake valve block Brake release valve flushing valve etc. Port BR (brake release) Port A BT brake valve block F12- motor NOTE: Detailed information on the BT valve is provided in publication Mobile motor/pump accessories (catalogue HY /UK). Port B Port S (make-up) Type SR pressure relief/make-up valve The SR pressure relief/make-up valve block for series F12 motors is designed to protect the motor from high pressure spikes as well as provide an excellent makeup function to help prevent motor cavitation (when port G is pressurized). The valve block mounts between the motor port flange and the split flanges (as shown to the right). The SR block is available in three sizes: Port G - SR11 ( 3 / 4 ") for F12-30, -40, SR12 (1") for F12-80, SR13 (1 1 / 4 ") for F12-110, -125 SR valve block NOTE: - For additional information such as pressure settings and installation dimensions, refer to publication Mobile motor/pump accessories (catalogue HY /UK). - To obtain a combined cross-over relief/ make-up and flushing function on the F12-110, -125, the SR13 and FV13 valve blocks can be stacked (with the flushing valve block mounted next to the motor). Port G Port L SR valve block F12-motor Port A Port B F12_SR_schem.eps 42 Parker Hannifin

43 Technical information Type SV pressure relief valve The SV pressure relief valve for series F12 motors protects the motor and the corresponding main hydraulic lines from pressure spikes. Like the SR valve block (page 42), it has integrated cartridge type pressure relief valves and mounts between the motor port flange and the split flanges as shown to the right. The design of the relief valves permits a limited makeup flow (when port L is pressurized). The SV valve block is available in three sizes: - SV11 ( 3 / 4 ") for F12-30, -40, SV12 (1") for F12-80, SV13 (1 1 / 4 ") for F12-110, -125 NOTE: - Detailed information on available pressure settings, installation dimensions, etc. is provided in publication Mobile motor/pump accessories (catalogue HY /UK). - On the F12-110, -125, the FV13 flushing valve block (page 41) can be mounted between the SV13 block and the motor port flange to obtain a combined pressure relief and flushing function. Speed sensor A speed sensor kit is available for series F11/F12. A ferrostat differential (Hall-effect) sensor installs in a separate, threaded hole in the F11/F12 bearing housing. On F12 the speed sensor is directed towards the ring gear.on F11 the speed sensor is directed towards the pistons. The sensor output is a 2 phase shifted square wave signal within a frequency range of 0 Hz to 15 khz. NOTE: - The motor bearing housing must be prepared for the speed pick-up; refer to the F11/F12 ordering codes (pages 7-12). - On F11 the pistons position must be known before mounting. - Additional information is provided in the Instruction (catalogue HY /UK). - The speed sensor is also shown in the illustrations on pages 20, 25, 28, 32, 36 and 38. SV pressure relief valve block Port A Port B (Port L) SV valve block F12_SV_schem.eps F12 with speed sensor. Speed sensor Speed sensor F11-14 with speed sensor. 43 Parker Hannifin

44 Installation information Direction of rotation The M and H versions of series F11, and the M version of series F12, are bi-directional. The L and R pump versions are uni-directional, allowing higher selfpriming speeds (refer to page 16). The illustration to the right shows direction of flow versus shaft rotation. In a motor application, the shaft turns clockwise when port B (black arrow) is pressurized, and counter clockwise when port A (open arrow) is pressurized. In a pump application where the shaft turns clock-wise, port B is the inlet port and should be connected to tank; when the shaft turns counter clockwise, port A is the inlet port. Counter clockwise rotation Port A Clockwise rotation Port B Hydraulic fluids Ratings and performance data for series F11/F12 are based on operating with good quality, contaminationfree, petroleum-based fluids. Hydraulic fluids type HLP (DIN 51524), automatic transmission fluids type A, or API CD engine oils can be used. Fire resistant fluids (when used under modified operating conditions) and synthetic fluids may also be suitable. For additional information, refer to Hydraulic Marketing IS data base: - Hydraulic fluid specifications - Fire resistant fluids. NOTE: When operating the F11/F12 as a pump above the selfpriming speed (valid for both the pump and motor versions), the inlet must be sufficiently pressurized. Increased noise and deteriorating performance may otherwise be experienced. For further information refer to Selfpriming speed and required inlet pressure on page 6. Operating temperature The following temperatures should not be exceeded (type H and N shaft seals): Main circuit 70 C Drain circuit: 90 C. FPM shaft seals ( type E, type V) can be used to 115 C drain fluid temperature. NOTE: The temperature should be measured at the utilized drain port. Continuous operation may require case flushing in order to meet the viscosity and temperature limitations. The following table shows operating speeds, above which flushing is usually required, as well as suggested flow through the case. Series F11 Frame size Speed [rpm] Flow [l/min] F F F F F F F Series F12 Frame size Speed [rpm] Flow [l/min] F F F F F F F Parker Hannifin

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement Hydraulic Motor/Pump Series F11/F12 Fixed Displacement Series F11/F12 Torque (M) M = D x p x η hm 63 [Nm] Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5 psi 1 l...0.264

More information

Hydraulic Motor/Pump Series F11/F12 zp12

Hydraulic Motor/Pump Series F11/F12 zp12 Hydraulic Motor/Pump zp12 Fixed Displacement zp11 Catalogue HY17-8249/US March 2004 Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5 psi 1 l...0.264 US gallon 1 cm

More information

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde Hydraulic Motor/Pump Series F11/F12 Fixed Displacement parker.com/pmde Series F11/F12 Torque (M) M = D x p x η hm 63 [Nm] Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5

More information

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde Hydraulic Motor/Pump Series F11/F12 Fixed Displacement parker.com/pmde Series F11/F12 Torque (M) M = D x p x η hm 63 [Nm] Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5

More information

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde Hydraulic Motor/Pump Series F11/F12 Fixed Displacement parker.com/pmde Series F11/F12 Torque (M) M = D x p x η hm 63 [Nm] Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5

More information

Hydraulic Motor Series V12 Variable Displacement

Hydraulic Motor Series V12 Variable Displacement Variable Displacement Catalog 9129 8217-02 June, 1998 GB Content General information 3 V12 cross section 3 Specifications 4 Efficiency diagrams 5 Ordering codes 6 Installation dimensions - ISO version

More information

Service Manual Series F12

Service Manual Series F12 Bulletin HY30-5504-M1/UK Effective: June, 2006 Supersedes: August, 2003 List of contents Page General information...3 Specifications...4 Disassembling...5-10 Assembling...11-16 Change of shaft seal...17

More information

Hydraulic Motors. Series V12, V14, T12 Variable Displacement

Hydraulic Motors. Series V12, V14, T12 Variable Displacement Series V12, V14, T12 Variable Displacement General information Series V12, V14 and T12 Basic formulas for hydraulic motors ) Displacement (D α ) D α = D 35 x sin α [cm 3 /rev] sin 35 α - displacement angle

More information

Truck Hydraulics. Series F1, F2, T1 Fixed Displacement Pumps

Truck Hydraulics. Series F1, F2, T1 Fixed Displacement Pumps Series F1, F2, T1 Fixed Displacement Pumps aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Contents Hydraulic Pumps,

More information

Hydraulic Motors. Series V12, V14, T12 Variable Displacement

Hydraulic Motors. Series V12, V14, T12 Variable Displacement Series V12, V14, T12 Variable Displacement General information Series V12, V14 and T12 Torque (M) M = D x p x η hm [Nm] 63 Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft 1 bar...14.5

More information

Truck Hydraulics. Serie VP1 Variable Displacement Pumps

Truck Hydraulics. Serie VP1 Variable Displacement Pumps ruck Hydraulics Variable Displacement Pumps aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Contents Pump and line

More information

Hydraulic Pump Series F1plus Fixed Displacement

Hydraulic Pump Series F1plus Fixed Displacement Fixed Displacement Catalog 9129 8218-02 February 1999, GB Content General information, design 3 Specifications 4 Pump cross section 4 Pump and line selection 5 Ordering code 6 Standard versions 6 Installation

More information

MOTOR SCM ISO

MOTOR SCM ISO MOTOR SCM 012-130 ISO SCM 012-130 ISO is a range of robust axial piston motors especially suitable for mobile hydraulics. SCM 012-130 ISO is of the bent-axis type with spherical pistons. The design results

More information

MOTOR SCM M2

MOTOR SCM M2 MOTOR SCM 025 108 M2 Sunfab SCM M2 is a range of robust axial piston motors especially suitable for winch-, slewing-, wheeland track drives. Sunfab SCM M2 is of the bent-axis type with spherical pistons.

More information

SCM M2. Other advantages:

SCM M2. Other advantages: Sunfab s SCM 025-108 M2 is a range of robust axial piston motors with cartridge flange especially suitable for winch-, slewing-, wheel- and track drives. SCM 025-108 M2 is of the bent-axis type with spherical

More information

SCM ISO. SCM ISO is a range of robust axial piston motors especially suitable for mobile hydraulics.

SCM ISO. SCM ISO is a range of robust axial piston motors especially suitable for mobile hydraulics. SCM 010-130 ISO is a range of robust axial piston motors especially suitable for mobile hydraulics. SCM 010-130 ISO is of the bent-axis type with spherical pistons. The design results in a compact motor

More information

Mobile Motor/Pump. Accessories

Mobile Motor/Pump. Accessories Mobile Motor/Pump ccessories aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Content Contents Page -1- Speed sensor

More information

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories Conversion factors 1 kg... 2,20 lb 1 N... 0,225 lbf 1 Nm... 0,738 lbf ft 1 bar...14,5 psi 1 l...0,264 US

More information

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics.

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics. Sunfab s SCM 010-130 SAE is a range of robust axial piston motors especially suitable for mobile hydraulics. SCM 010-130 SAE is of the bent-axis type with spherical pistons. The design results in a compact

More information

Hydraulic Pump Series VP1 Variable Displacement

Hydraulic Pump Series VP1 Variable Displacement Variable Displacement Catalog 9129 8222-02 February 1999, GB Content Page General information 3 Design 3 Specifications 4 Ordering information 4 VP1 cross section 4 Installation dimensions 5 Line dimensioning

More information

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs Gear Pumps / Motors Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs Table of contents Heavy-duty Pumps and Motors Series PGP, PGM Contents Page Series 500 Aluminium Table of

More information

Hydraulic Pump Series F1 Fixed Displacement

Hydraulic Pump Series F1 Fixed Displacement Fixed Displacement Catalog 9129 8201-02 August, 1997 GB Content General information 3 Specifications 4 Pump and line selection 5 Ordering code 5 Standard versions 5 Installation dimensions 6 Installation

More information

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories Conversion factors 1 kg... 2,20 lb 1 N... 0,225 lbf 1 Nm... 0,738 lbf ft 1 bar...14,5 psi 1 l...0,264 US

More information

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW AXIAL PISTON PUMPS SHPV SECTIONAL VIEW 2 SYSTEM CIRCUIT PUMP AND MOTOR CIRCUIT working loop (high pressure) working loop (low pressure) control fluid suction line case drain fluid Above figure shows schematically

More information

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics.

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics. Sunfab s SCM 010-130 SAE is a range of robust axial piston motors especially suitable for mobile hydraulics. SCM 010-130 SAE is of the bent-axis type with spherical pistons. The design results in a compact

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK April 2003

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK April 2003 Fixed and Variable Displacement Pumps, Motors and Accessories Catalogue HY17-8200/UK April 2003 F1 F2 T1 VP1 PTO info Accessories Conversion factors 1 kg 2.20 lb 1 N 0.225 lbf 1 Nm 0.738 lbf ft 1 bar 14.5

More information

AXIAL PISTON MOTORS SHMF

AXIAL PISTON MOTORS SHMF SECTIONAL VIEW Purge relief valve High pressure relief valves (adjustable) Cylinder block assembly Shaft seal Output shaft Valve block Shuttle valve Swashplate 2 SYSTEM CIRCUIT PUMP AND MOTOR CIRCUIT working

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

SCM DIN. Other advantages:

SCM DIN. Other advantages: SCM 012-130 DIN SCM 012-130 DIN is a series of axial piston motors particularly suitable for mobile hydraulics. SCM 012130 DIN is of the bent-axis type with spherical pistons. Other advantages: The design

More information

Fixed Displacement Motor AA2FM (A2FM)

Fixed Displacement Motor AA2FM (A2FM) Fixed Displacement Motor 2FM (2FM) Series 6, for Open and Closed Circuits xial Piston, ent xis Design 5800 psi 6500 psi rueninghaus Hydromatik Sizes 5 1000 Nominal Pressure up to Peak Pressure up to (400

More information

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW AXIAL PISTON PUMPS SHPV SECTIONAL VIEW 2 AXIAL PISTON PUMPS SHPV SYSTEM CIRCUIT PUMP AND MOTOR CIRCUIT working loop (high pressure) working loop (low pressure) control fluid suction line case drain fluid

More information

Series TMM Axial Piston Motor. Technical Information

Series TMM Axial Piston Motor. Technical Information Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer

More information

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007 Design 45 Variable Displacement February 2007 Introduction With thru drive for single and multiple pumps Swash plate type for open circuit Technical Features Low noise level Fast response (eg. PV046: upstroke

More information

Axial Piston Fixed Motor A2FM

Axial Piston Fixed Motor A2FM Axial Piston Fixed Motor A2FM RE 91001/06.2012 1/46 Replaces: 09.07 Data sheet Series 6 Size Nominal pressure/maximum pressure 5 315/350 bar 10 to 200 400/450 bar 250 to 1000 350/400 bar Open and closed

More information

Fixed Displacement Motor A10FM A10FE

Fixed Displacement Motor A10FM A10FE Electric Drives and Controls Hydraulics inear Motion and ssembly Technologies Pneumatics Service Fixed Displacement Motor 10FM 10FE RE 91 172/06.06 1/24 Replaces: 01.03 Technical Data Sheet Size 10...63

More information

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s H y d r a u l i c s ydraulics Eaton Medium Duty Piston Pump h y d r a u l i c s Model 70122, 70422, 70423, and 70523 or -Flow Compensated Piston Pumps We Manufacture April 1997 Solutions S o l u t i o

More information

Fixed Displacement Bent Axis Axial Piston Motors TMB 700

Fixed Displacement Bent Axis Axial Piston Motors TMB 700 HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001:2015-14001:2015 ISO 9001:2015 Certificate N 12-Q-0200545-TIC ISO 14001:2015 Certificate N 12-E-0200545-TIC

More information

TMF 600 ( cm³/rev.)

TMF 600 ( cm³/rev.) HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001-14001 ISO 9001 Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415

More information

External Gear Pumps Series F

External Gear Pumps Series F External Gear Pumps Series F RA 10089/08.11 Replaces: RA 10097 1/60 AZPF-... Fixed pumps Size 4.0...28 cm 3 /rev (.25-1.71 in 3 /rev) Overview of contents Contents Page General 2 Product overview 3 single

More information

High Torque Low Speed Motors MR - MRE

High Torque Low Speed Motors MR - MRE High Torque Low Speed Motors MR - MRE Calzoni Radial Piston Technology aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding

More information

Variable Displacement Motor AA6VM (A6VM)

Variable Displacement Motor AA6VM (A6VM) Variable Displacement otor 6V (6V) Series 6, for open and closed circuits xial tapered piston - bent axis design 5800 psi Sizes 28 1000 Nominal Pressure up to (400 bar) Peak Pressure up to 6500 psi (450

More information

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass Electric Drives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics Service xial Piston Fixed Motor 2FNM for Fan Drives and Flywheel Mass RE 91007/02.11 1/16 Data sheet Series 61

More information

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design Sizes 71 0 Nominal pressure 3 bar Peak pressure 400 bar RE 91455/01.94 RE 91455/01.94 Replaces 07.88 Other fixed displacement

More information

Gear Pumps. Series PGP Fixed Displacement Pumps, Cast-Iron Designs

Gear Pumps. Series PGP Fixed Displacement Pumps, Cast-Iron Designs Gear Pumps Series PGP Fixed Displacement Pumps, Cast-Iron Designs aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Table

More information

Axial Piston Variable Pump AA4VG

Axial Piston Variable Pump AA4VG Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Axial Piston Variable Pump AA4VG RA 92003-A/06.09 1/64 Replaces: 03.09 Data sheet Series 32 Size 28...

More information

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model AA4VSE Plug-in dual displacement motor Series Axial piston swashplate design, SAE model RE 91808/09.90 RE 91808/09.90 Brueninghaus Hydromatik Size 250 Nominal pressure 350 bar Peak pressure 400 bar High

More information

Gear Motors. Series PGM Fixed Displacement Motors, Aluminium Designs

Gear Motors. Series PGM Fixed Displacement Motors, Aluminium Designs Gear Motors Series PGM Fixed Displacement Motors, Aluminium Designs aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding

More information

Axial Piston Fixed Pump A17FNO Series 10

Axial Piston Fixed Pump A17FNO Series 10 Axial Piston Fixed Pump A17FNO Series 10 RE 91510 Issue: 06.2012 Replaces: 03.2010 Size 125 Nominal pressure 250 bar Maximum pressure 300 bar For commercial vehicles Open circuit Features Fixed pump with

More information

Fixed Displacement Pump A2FO

Fixed Displacement Pump A2FO RE 91401/01.97 Brueninghaus Hydromatik eries 6, for open circuits Axial tapered piston - bent axis design izes 5...1000 Nom. Pressure up to 400 bar Peak Pressure up to 4 bar RE 91401/01.97 replaces 11.95

More information

US version. Drain connection

US version. Drain connection Versions OMT Versions Mounting flange Standard flange Shaft Port size Europea n version US version Drain connection Check valve Low pressure release High pressure release Cyl. 4 mm G 3/4 X Yes Yes OMT

More information

Fixed Displacement Motor A2FM

Fixed Displacement Motor A2FM rueninghaus Hydromatik Series 6, for use in open and closed circuits xial tapered piston - bent axis design Sizes 5...1000 Nom. Pressure up to 400 bar Peak Pressure up to 4 bar RE 91001/01.97 RE 91001/01.97

More information

AP212 Gear Pumps. Standard and Low Noise series. Reference: 200-P EN-03 1/60. Issue:

AP212 Gear Pumps. Standard and Low Noise series. Reference: 200-P EN-03 1/60. Issue: Gear Pumps Standard and Low Noise series Reference: 2-P-99123-EN-3 Issue: 9.215 1/6 Contents Page 1 General information... 4 1.1 External gear pumps components... 5 1.2 Example of typical sound pressure

More information

Radial piston hydraulic motor Hägglunds CAb

Radial piston hydraulic motor Hägglunds CAb Radial piston hydraulic motor Hägglunds CAb RE 15354 Edition: 12.2016 Replace: 01.2015 Frame Size: CAb 10, 20, 30, 40 Displacement: 503 2 513 cm 3 /rev [31-153 in 3 /rev] Specific torque: 8 40 Nm/bar [407

More information

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit Introduction *not included Pump with standard compensator, code: "omit" With thru shaft option for multiple pump options Swash plate type for open circuit Pump with load sensing, code: "A" Mounting style

More information

Low Speed High Torque Motors

Low Speed High Torque Motors Low Speed High Torque Motors Catalogue HY29-0503/UK TABLE OF CONTENTS Table of contents Features General information Functional description Technical data 3 4 4 5 6 FRAME SIZE P Operating diagrams Overall

More information

Medium Duty Piston Pump Variable Displacement Closed Circuit

Medium Duty Piston Pump Variable Displacement Closed Circuit Medium Duty Piston Pump Variable Displacement Closed Circuit Model 70160 Model 70360 Model 72400 20.3 cm 3 /r [1.24 in 3 /r] 40.6 cm 3 /r [2.48 in 3 /r] 40.6 cm 3 /r [2.48 in 3 /r] 23.6 cm 3 /r [1.44 in

More information

Hydraulic Pumps T7 for variable speed drives

Hydraulic Pumps T7 for variable speed drives FC Hydraulic Pumps T7 for variable speed drives Denison Vane Technology Catalogue HY29-11/UK Content General Information Introduction and product key features 3 Main Technical Data Main table for single

More information

RA / Radial Piston Motor Model MR, MRE Fixed Displacement. Table of Contents. Replaces: RA /10.95

RA / Radial Piston Motor Model MR, MRE Fixed Displacement. Table of Contents. Replaces: RA /10.95 Radial Piston Motor Model MR, MRE Fixed Displacement Sizes 160 to 9500 6100 PSI (up to 420 bar) 582 in 3 (up to 9542 cm 3 ) 25,075 lb-ft (up to 34000 Nm) RA 15 228/10.95 Replaces: 12.94 Wide range of displacements

More information

External gear pump Series G

External gear pump Series G External gear pump Series G RE 10 093/04.14 Replace RE 10 093/06.13 AZPG-22 Fixed pumps V = 22.5...100 cm 3 / rev Overview of contents Contents Page General 2 Product overview 3 Ordering code single pumps

More information

Series 20 Axial Piston Motors. Technical Information

Series 20 Axial Piston Motors. Technical Information Series 20 xial Piston Motors Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston motors. DESCRIPTION Sauer-Danfoss

More information

Hydraulic Fixed Piston Rexroth A2FE Motor

Hydraulic Fixed Piston Rexroth A2FE Motor Hydraulic Fixed Piston Rexroth A2FE Motor Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HM(HD)B 270 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3

More information

Truck Hydraulics. Series GPA, GP1, F1, T1, F2, F3, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.

Truck Hydraulics. Series GPA, GP1, F1, T1, F2, F3, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker. Series GPA, GP1, F1, T1, F2, F3, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories parker.com/pmde Pumps and Motors Change History for edition 01.2017 Pages 9, 42-46: New F3 pump incorporated.

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3 4. Performance

More information

P2060 P2075 P2105 P2145 P3105 P3145

P2060 P2075 P2105 P2145 P3105 P3145 Technical Information Technical Features P2 Series Compact design Low noise level Service friendly Reliable Long-lasting Flexible Easy to install High self-priming speed Technical Data P3 Series P2 Series

More information

Variable displacement axial piston pump type V30D

Variable displacement axial piston pump type V30D Variable displacement axial piston pump type V30D for open circuit Pressure p max Displacement V max = 420 bar (6000 psi) = 260 cm 3 /rev (16.16 cu in/rev) 1.2 1. General description The axial piston variable

More information

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325 Staffa Fixed Displacement Hydraulic Motor CONTENTS Page 1. General Description... 2 2. Functional Symbols... 2 3. Model Code... 3 4. Performance

More information

Hydraulic Pump VP1-120

Hydraulic Pump VP1-120 REECHSROY GROUP REECHNOLOGY Bulgaria, Varna 9000 Industrial Zone Str. Studentska 1 U/UK1 odernization, complex repair and maintenance of heavy industrial equipment. Infrastructure construction and management

More information

AP212HP Cast Iron Gear Pumps

AP212HP Cast Iron Gear Pumps Cast Iron Gear Pumps Standard and Low Noise series Reference: 200-P-991236-EN-01 Issue: 09.2016 1/56 Contents Page 1 General information... 5 1.1 External gear pumps components... 6 1.2 Technical data...

More information

Fixed Displacement Plug-In Motor A2FE

Fixed Displacement Plug-In Motor A2FE Industrial Hydraulics Electric Drives and Controls Linear Motion and ssembly echnologies Pneumatics Service utomation Mobile Hydraulics Fixed Displacement Plug-In Motor 2FE RE 9008/03.97 replaces 04.96

More information

MOTORS M HYDRAULIC MOTORS

MOTORS M HYDRAULIC MOTORS MOTORS M HYDRAULIC MOTORS T E C H N I C A L C A T A L O G Fixed displaced axial piston motors POCLAIN HYDRAULICS Displacement cm³/rev [in³/rev.] M0 M1 M2 M3 From 7,07 [0.43] to 17,84 [1.09] From 9,08 [0.55]

More information

Variable Displacement Pump A4VG for closed circuits

Variable Displacement Pump A4VG for closed circuits RE 92 003/05.99 RE 92 003/05.99 replaces: 02.98 Variable Displacement Pump A4VG for closed circuits Sizes 28...250 Series 3 Nominal pressure 400 bar Peak pressure 450 bar A4VG...EP Index Features 1 Ordering

More information

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces: Axial piston variable pump A4VG Series 32 Europe RE-E 92003 Edition: 04.2016 Replaces: 06.2012 High-pressure pump for applications in a closed circuit Size 28 to 125 Nominal pressure 400 bar Maximum pressure

More information

Series 90 Axial Piston Motors. Technical Information

Series 90 Axial Piston Motors. Technical Information Series 90 Axial Piston Motors Technical Information HISTORY OF REVISIONS Table of Revisions Date Page Changed Rev. Fourth edition 2 520L0604 Contents GENERAL DESCRIPTION Cross section Cross section Cross

More information

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES THE PRODUCTION LINE OF HANSA-TMP Variable Displacement Closed Loop System CONTENTS General Information... Order Code... Manual Control

More information

Vane motor high performance hydraulic series M5B - M5BS - M5BF

Vane motor high performance hydraulic series M5B - M5BS - M5BF Vane motor high performance hydraulic series M5B - M5BS - M5BF Publ. 2 - AM172 - B 1 / 25 / FB Replaces : 2 - AM172 - A L11-2172 - 2 CHARACTERISTICS - M5B* SERIES LOW NOISE MOTOR 12 vanes and a patented

More information

AXIAL PISTON PUMPS AND MOTORS

AXIAL PISTON PUMPS AND MOTORS HPV-HMF SERIES SECTIONA VIEW AXIA PISTON VARIABE DISPACEMENT PUMP AXIA PISTON FIXED DISPACEMENT MOTOR Purge relief valve High pressure relief valves (adjustable) Cylinder block assembly Shaft seal Output

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2661-CD/US zp2 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference Only

More information

Distribuíção, revenda emanutenção. CatálogosOnline. (11) (11)

Distribuíção, revenda emanutenção. CatálogosOnline. (11) (11) Distribuíção, revenda emanutenção CatálogosOnline (11)4174-3300-(11)4765-6775 www.hmc.com.br MAKING MODERN LIVING POSSIBLE Technical Information Axial Piston Pumps Series 20 powersolutions.danfoss.com

More information

Axial Piston Fixed Pump A2FO

Axial Piston Fixed Pump A2FO Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics ervice Axial Piston Fixed Pump A2FO RE 91401/03.08 1/24 Replaces: 09.07 Technical data sheet eries 6 izes Nominal

More information

Axial Piston Variable Pump (A)A4VSG (US-Version)

Axial Piston Variable Pump (A)A4VSG (US-Version) Electric Drives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics Service xial Piston Variable Pump ()4VSG (US-Version) R- 92100/12.12 1/72 Replaces: 10.97 Data sheet Series 10,

More information

Axial piston variable pump (A)A4VSO

Axial piston variable pump (A)A4VSO Axial piston variable pump (A)A4VSO RA 92050-A/06.09 1/64 Replaces: 09.97 Data sheet Series 10, 11 and 30 Size 40...1000 Nominal pressure 5100 psi (350 bar) Peak pressure 5800 psi (400 bar) Open circuit

More information

Axial Piston Variable Pump A4VG

Axial Piston Variable Pump A4VG Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Axial Piston Variable Pump A4VG RE 92003/03.09 1/64 Replaces: 09.07 Data sheet Series 32 Sizes 28...250

More information

Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives

Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives Axial piston units A10FZO, A10VZO and A10FZG, A10VZG Series 10 for variable-speed drives RE 91485 Edition: 10.2016 Replaces: 06.2011 For variable-speed operation with synchronous and asynchronous motors

More information

2.3 MEDIUM HEAVY DUTY SERIES

2.3 MEDIUM HEAVY DUTY SERIES 2 2.3 MEDIUM HEAVY DUTY SERIES CONTENTS PPV11 Ordering Code 2.3.1 Medium Heavy Duty Series 2.3.2 Torque limiter settings Technical Information 2.3.3 Specifications 2.3.4 Hydraulic fluids 2.3.5 Viscosity

More information

HYDRAULIC MOTORS MM APPLICATION OPTIONS CONTENTS GENERAL MOTORS

HYDRAULIC MOTORS MM APPLICATION OPTIONS CONTENTS GENERAL MOTORS HYDRAULIC APPLICATION Conveyors Textile machines Mining machinery Machine tools Ventilators Construction plant equipment and access platforms etc. CONTENTS Specification data... 5 Function diagrams...

More information

Technical Information Series 45 G Frame powersolutions.danfoss.com

Technical Information Series 45 G Frame powersolutions.danfoss.com MAKING MODERN LIVING POSSIBLE Technical Information Series 45 G Frame powersolutions.danfoss.com Contents Frame G Design... 4 Specifications... 5 Performance G74B... 6 Performance G9C... 7 Order code...

More information

Variable Displacement Plug-In Motor A6VE

Variable Displacement Plug-In Motor A6VE Electric Drives and Controls Hydraulics Linear Motion and Assembly echnologies Pneumatics Service Variable Displacement Plug-In Motor A6VE RE 91 606/06.05 1/16 Replaces: 05.99 echnical data sheet Series

More information

OMEW Hydraulic Motor Versions

OMEW Hydraulic Motor Versions Versions VERSIONS Mounting flange Wheel Shaft Port size European version US version Clockwise shaft rotation (CW version) 1) Counter clockwise shaft rotation (CCW version) 1) Tapered 35 mm G 1 /2 X X X

More information

Axial piston fixed motor A2FM series 70. Americas. RE-A Edition:

Axial piston fixed motor A2FM series 70. Americas. RE-A Edition: Axial piston fixed motor A2FM series 70 Americas RE-A 91071 Edition: 05.2015 A2FMN (Sizes 90 and 107): Nominal pressure 300 bar Maximum pressure 350 bar A2FMM (Sizes 80 and 90): Nominal pressure 400 bar

More information

B e n t a x i s hydraulic motors. MSeries

B e n t a x i s hydraulic motors. MSeries B e n t a x i s hydraulic motors MSeries Contents Definition and main applications of hydraulic motors, advantages of HYDRO LEDUC motors.............. 1 Operating conditions of motors... 2 Determining

More information

Variable displacement axial piston pumps,

Variable displacement axial piston pumps, Variable displacement axial piston pumps, Edition: 04/04.2000 Replaces: 04/10.99 DISPLACEMENTS From To PRESSURE Max. continuous Max. intermittent Max. peak 29 cm 3 /rev 73 cm 3 /rev 280 bar 315 bar 350

More information

TPF 60 (36,16 49,94 cm³/rev.)

TPF 60 (36,16 49,94 cm³/rev.) HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001-14001 ISO 9001 Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415

More information

Spool Valve Hydraulic Motors Series J

Spool Valve Hydraulic Motors Series J Spool Valve Hydraulic Motors Series J 10.201 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.201 EN EATON_Motoren J Series english J Series Highlights Thrust Bearing Bushing Port B Port

More information

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL 16 100/110 ED VPPM VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE The VPPM pumps are variable displacement axial-piston pumps with variable swash plate, suitable for applications with open

More information

J Series (129-) Highlights

J Series (129-) Highlights Highlights Features: Constant clearance Geroler set Integrated check valves Thrust Bearing Bushing Port B Port A Self-lubricating shaft bushing High-strength rigid components Increased valve seal lands

More information

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series General Information General Information P2 Series The newly developed variable displacement piston pumps from Parker Hannifin, designated P2, are intended for mobile applications, featuring a very compact

More information

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA Catalog HY28-6/NA PV, PVT Series Piston Pumps Variable Volume Catalog HY28-6/NA 1 Catalog HY28-6/NA Notes Series PV 2 Catalog HY28-6/NA Introduction Series PV Quick Reference Data Chart Pump Delivery Approx.

More information

Variable displacement axial piston pumps,

Variable displacement axial piston pumps, ariable displacement axial piston pumps, for open circuit DISPLACEMENTS From To 2.75 in 3 /rev (45 cm 3 /rev) 5.12 in 3 /rev (84 cm 3 /rev) MAX SPEED 3000 min -1 PRESSURE Max. continuous Max. intermittent

More information