LED8WPAR20/NFL/830-DIM

Size: px
Start display at page:

Download "LED8WPAR20/NFL/830-DIM"

Transcription

1 LED8WPAR2/NFL/83-DIM

2 EiKO Global, LLC Model: LED8WPAR2/NFL/83-DIM TABLE OF CONTENTS 1 - GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) OBJECTIVE TEST FACILITY DESCRIPTION TEST EQUIPMENT LIST TEST METHOD SUMMARY OF TEST RESULT SPECTRAL FLUX PLOTS EUT PHOTOS LUMINOUS INTENSITY DISTRIBUTION TEST PLOTS (CIE CHROMATICITY)... 9 Report No.BTR Page 2 of 9 IESNA LM-79 Test Report

3 EiKO Global, LLC Model: LED8WPAR2/NFL/83-DIM 1 - GENERAL INFORMATION 1.1 Product Description for Equipment under Test (EUT) Applicant : EiKO Global, LLC Product Name Model No Brand Nominal Operation Voltage Nominal Power Nominal CCT Nominal CRI Nominal Lumen Output Nominal Life Time Stabilization Time Total operating time for measurement include stabilization time Nominal Shape of Bulb(Designation) : : LED : LED8WPAR2/NFL/83-DIM : Litespan : AC 12V : 8W : 3K : 82 : 47Lumens : 4Hours : 1. hours : 2.5 hours Standard Omnidirectional A, BT, P, PS, S, T Decorative B, BA, C, CA, DC, F, G Directional PAR, MR, R, BR Date of Receiving Sample : May 16, 213 Measurement quantities measured : 1 pcs Orientation During Testing : Base Up Test Requested : 1. Electrical and Photometric Test; 2. Luminous Intensity Distribution Test. Non Standard 1.2 Objective The following test report is prepared on behalf of EiKO Global, LLC in accordance with IESNA LM-79-8, used the following American National Standards or illumination Engineering Society of North America test guides: ANSI C : Specifications for the Chromaticity of Solid State Lighting Products; ANSI C : American National Standard for Electric Lamps Nomenclature for Glass Bulbs Intended for Use with Electric Lamps; ANSI C : American National Standard for Electric Lamps A, G, PS, and Similar Shapes with E26 Medium Screw Bases; ANSI C : American National Standard for Electric Lamps PAR and R Shapes; ANSI C : American National Standard for Electric Lamps Two-inch (51 mm); Integral-reflector Lamps with Front Covers and GU5.3 or GX 5.3 Bases; ANSI/IEC C : American National Standard for Electric Lamp Bases; ANSI/IEEE C (1-May-1991): Surge Voltages in Low-Voltage AC Power Circuits, Recommended Practice for; CIE Publication No : Method of Measuring and Specifying Color Rendering of Light Sources; CIE Publication No : The Basis of Physical Photometry; IESNA LM : Practical Guide to Colorimetry of Light Sources; IESNA LM : Guide for the Selection, Care, and Use of Electrical Instruments in the Photometric Laboratory; IESNA LM-79-8 Electrical and Photometric Measurement of Solid State Lighting Products UL : Standard for Self-Ballasted Lamps and Lamp Adapters; UL : Light Emitting Diode (LED) Equipment for Use in Lighting Products. Report No.BTR Page 3 of 9 IESNA LM-79 Test Report

4 EiKO Global, LLC Model: LED8WPAR2/NFL/83-DIM 1.3 Test Facility Description The Energy Efficiency Lab used by BEST to collect energy efficiency measurement data is located in 1st Floor, 1st Building, Weitai Industrial Park, Yingrenshi, Shiyan, Baoan, Shenzhen, China. BEST Test Service Shenzhen Co., Ltd is a National Institute of Standards and Technology (NIST) accredited laboratory, under the National Voluntary Laboratory Accredited Program (Lab Code 277-). BEST Test Service Shenzhen Co., Ltd is also an ELI accredited lab for lighting products (ELI Certificate No. ELI-L4-21) and UL accredited lab for lighting products 1.4 Test Equipment List Device Manufacture Model No Serial No Cal. Date Cal Due Date Integral Sphere Integral Sphere Everfine Everfine 1.5M SPEKTRON 1.5M SPEKTRON 684T Oct 2, 212 Oct 2, Oct 2, 212 Oct 2, 213 Integral Sphere Labsphere LMS Mar 1, 213 Mar 9, 214 Spectro Meter Assy Labsphere CDS Mar 1, 213 Mar 9, 214 Plus UV-VIS-Near IR Spectrophotometer Colorimeter Plus UV-VIS-Near IR Spectrophotometer Colorimeter Everfine Everfine PMS-5 (38nm-8nm) PMS-7 (2nm-8nm) 6833 Oct 2, 212 Oct 2, Oct 2, 212 Oct 2, 213 Goniophotometer Everfine GOR Nov 2, 212 Nov 19, /2 Digital Multimeter Agilent 3441A MY Oct 18, 212 Oct 17, 213 AC Power Source AC Power Source California Instrument California Instrument 151I S1393 N/A N/A 151L L3572 N/A N/A Standard Light Source OSRAM 24V/5W NO.1 Sep 17, 212 Sep 16, 213 Standard Light Source OSRAM 24V/5W NO.2 Sep 17, 212 Sep 16, 213 Multi-Function AC standard Meter Everfine PF21S 651 Oct 18, 212 Oct 17, 213 Digital Power Meter Everfine PF Oct 18, 212 Oct 17, 213 Digital Power Meter YOKOGAWA WT21 91K319 Oct 18, 212 Oct 17, 213 Digital Power Meter YOKOGAWA WT21 91K3117 Oct 18, 212 Oct 17, 213 Digital Power Meter YOKOGAWA WT21 91K3116 Oct 18, 212 Oct 17, 213 Ballast Parameter Analyzer Everfine PF Oct 18, 212 Oct 17, 213 Second Meter TIANFU PC 396 N/A Oct 18, 212 Oct 17, 213 Digital Storage Tektronix TDS212B C51911 Oct 18, 212 Oct 17, 213 Oscilloscope Statement of Traceability: BEST Test Service Shenzhen Co., Ltd. certifies that all calibration has been performed using suitable standards traceable to the NIM China. Report No.BTR Page 4 of 9 IESNA LM-79 Test Report

5 EiKO Global, LLC Model: LED8WPAR2/NFL/83-DIM 2 - Test Method 2.1 Photometric and Electrical Measurement (Integrated Sphere Method) Total light output (luminous flux) for the 25 ±1 ambient temperature conditions is measured using an Everfine integrating sphere. Temperature is measured at a position inside the sphere. Spectral radiant flux measurements are made using PMS-7 to the detector port of the integrating sphere. Each lamp is operated at rated voltage in its designated orientation. Each lamp should be stable before measurements are made. The determining method of stable is as follows: Step 1 Take 3 measurements of the lamp light output at 15 minute interval (total time=3mintues.)this time period is in addition to the recommended pre-burning time. Step 2 Calculate the percent difference between the maximum measured value and the minimum measured value for the three consecutive measurements. Step 3 if the value calculated in Step 2 does not exceed.5 percent, the lamp is considered stable. Luminous flux, chromaticity coordinates, correlated color temperature and color rendering index for each lamp are calculated from the spectral radiant flux measurements taken at 2 nm intervals over the range 35 to 15 nm. The calibration of the sphere photometer-spectrometer system is traceable to the NIST USA. Lamp efficacy (lumens per watts) for each lamp model is computed based on the revised luminous flux result. Electrical measurements including voltage, current, power and power factor are measured using the YOKOGAWA WT21 digital power Meter. The total uncertainty of the light output measurements is estimated, at the 95% confidence level, not to exceed ±1.12% over the wavelength range nm. 2.2 Photometric and Electrical Measurement (GonioPhotometer Method) Before each measurement, the method below should be used to determine the lamp is stable or not. Step 1 Take 3 measurements of the lamp intensity at 15 minute interval (total time=3mintues.)this time period is in addition to the recommended pre-burning time. Step 2 Calculate the percent difference between the maximum measured value and the minimum measured value for the three consecutive measurements. Step 3 if the value calculated in Step 2 does not exceed.5 percent, the lamp is considered stable. A Everfine GOR-5 Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample; the photometric distance is 2.436m. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to be stable before measurement was made. Electrical measurements including voltage, current, power and power factor were measured using the YOKOGAWA WT21 Power Analyzer. Some graphics were created with Photometric Plus software. 2.3 Deviation from standard operating procedure None Report No.BTR Page 5 of 9 IESNA LM-79 Test Report

6 EiKO Global, LLC Model: LED8WPAR2/NFL/83-DIM 3 Summary of Test Result Item Test Result Accreditation Required Fields Lumen Output (Lumens) Luminous Efficacy (lm/w) Correlated Color Temperature (CCT) NVLAP/EPA NVLAP/EPA 2956 NVLAP/EPA Color Rendering Index CRI 82.5 NVLAP/EPA Input Power (W) 8.9 NVLAP/EPA Power Type AC DC / Input Voltage (V) Input Current (A) 12. NVLAP/EPA.712 NVLAP/EPA Power Factor.9469 NVLAP/EPA x(cie 1931).4415 NVLAP/EPA y(cie 1931).48 NVLAP/EPA u (CIE 1976).2518 NVLAP/EPA Optional Fields v (CIE 1976).5236 NVLAP/EPA Duv(CIE 1976) 1 NVLAP/EPA R9 5 NVLAP/EPA Beam Angle: (Degree) Center beam candlepower: (cd) 24.2 NVLAP/EPA NVLAP/EPA Zonal lumen density (-6 ): 95.7% NVLAP/EPA Zonal lumen density (6-9 ): 4.3% NVLAP/EPA Zonal lumen density (9-12 ): % NVLAP/EPA Zonal lumen density (12-18 ): % NVLAP/EPA Report No.BTR Page 6 of 9 IESNA LM-79 Test Report

7 EiKO Global, LLC Model: LED8WPAR2/NFL/83-DIM 4 Spectral Flux Plots Report No.BTR Page 7 of 9 IESNA LM-79 Test Report

8 EiKO Global, LLC Model: LED8WPAR2/NFL/83-DIM 5 EUT Photos Report No.BTR Page 8 of 9 IESNA LM-79 Test Report

9 EiKO Global, LLC Model: LED8WPAR2/NFL/83-DIM 6 Luminous Intensity Distribution Test Plots (CIE Chromaticity) This page is blank and see next page. Report No.BTR Page 9 of 9 IESNA LM-79 Test Report

10 BEST TEST SERVICE SHENZHEN CO., LTD. Page 1 Of 16 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.V I:.712A P:8.94W PF:.9469 Lamp Flux: x1 lm NAME: DIM.: MFR.: EiKO TYPE:LED8WPAR28/NFL/83-DIM SPEC.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE: DATA OF LAMP MODEL NOMINAL POWER(W) RATED VOLTAGE(V) NOMINAL FLUX(lm) LAMPS INSIDE TEST VOLTAGE(V) Imax(cd) LOR(%) TOTAL FLUX(lm) CIE CLASS up(%) down(%) PHOTOMETRIC DATA Eff: lm/w 1587 S/MH(C/18) S/MH(C9/27) UP,DN(C-18).,53.1 DIRECT UP,DN(C18-36).,46.9. CIBSE SHR NOM 1. CIBSE SHR MAX 1. LUMINOUS INTENSITY DISTRIBUTION DIAGRAM S(m) PLANAR ISOLUX DIAGRAM(UNIT:lx) C(DEG) / UNIT:cd C/18, C9/27,24.2 AVERAGE BEAM ANGLE(5%):24.2 DEG MH=1m C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

11 BEST TEST SERVICE SHENZHEN CO., LTD. Page 2 Of 16 ZONAL FLUX DIAGRAM AND LUMINANCE LIMITATION CURVES ZONAL FLUX DIAGRAM: C C45 C9 C135 C18 C225 C27 C315 zone total %lum,lamp , , , , , , , , , , , , , , , , , ,1 DEG LUMINOUS INTENSITY:cd UNIT:lm LUMINANCE LIMITATION CURVES GLARE CLASS ILLUMINANCE (lx) 1.15 A <=3 1.5 B <= C <=3 2.2 D <= E <=3 a b c d e f g h a b c d e f g h G(DEG) C/18 C9/27 LUMINANCE (cd/(m2)) a/h 2 LUMINANCE cd/(m2) G(DEG) C/18 C9/ C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

12 BEST TEST SERVICE SHENZHEN CO., LTD. Page 3 Of 16 CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM Test:U:12.V I:.712A P:8.94W PF:.9469 Lamp Flux: x1 lm NAME: DIM.: MFR.: EiKO TYPE:LED8WPAR28/NFL/83-DIM SPEC.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE: cc w fc RCR % 7% 5% 3% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 2% 2% 2% 2% RCR:Room Cavity Ratio Coefficients of Utilization(CU) % 5% 3% 1% 2% LAMPS 5 LUMINAIRE BUDGETARY DIAGRAM CONDITIONS 8 FLUX 5lm 7 FACTOR.7 6 Hdown m 5 Hwork m 4 Ework(AVE) 1lx cc w fc H=7 654 H= k 2k 3k 4k 5k 7k AREA(m2) C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

13 BEST TEST SERVICE SHENZHEN CO., LTD. Page 4 Of 16 WEC AND CCEC Test:U:12.V I:.712A P:8.94W PF:.9469 Lamp Flux: x1 lm NAME: DIM.: MFR.: EiKO TYPE:LED8WPAR28/NFL/83-DIM SPEC.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE: cc 8% 7% 5% 3% 1% w 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% fc 2% 2% 2% 2% 2% RCR RCR:Room Cavity Ratio Wall Exitance Coeffcients(WEC) cc w fc RCR % 7% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 5% 3% 1% 2% 2% 2% 2% 2% RCR:Room Cavity Ratio Ceiling Cavity Exitance Coefficients(CCEC) C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

14 BEST TEST SERVICE SHENZHEN CO., LTD. Page 5 Of 16 Uncorrected UGR Table Test:U:12.V I:.712A P:8.94W PF:.9469 Lamp Flux: x1 lm NAME: DIM.: MFR.: EiKO TYPE:LED8WPAR28/NFL/83-DIM SPEC.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE: ceiling/cavity walls working plane Room dimensions Viewed crosswise Viewed endwise x = 2H y = 2H 3H 4H 6H 8H 12H H 2H 3H 4H 6H 8H 12H H 4H 6H 8H 12H H 4H 6H 8H Variations with the observer position at spacings: S = 1.H +.5 / / H +.6 / / H +.8 / / -.5 CIE Pub.117 Corrected lm Total Lamp Luminous Flux.(8log(F/F) = -2.6) C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

15 BEST TEST SERVICE SHENZHEN CO., LTD. Page 6 Of 16 UTILIZATION FACTORS TABLE Test:U:12.V I:.712A P:8.94W PF:.9469 Lamp Flux: x1 lm NAME: DIM.: MFR.: EiKO TYPE:LED8WPAR28/NFL/83-DIM SPEC.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE: REFLECTANCE Ceiling Walls Working plane ROOM INDEX UTILIZATION FACTORS(PERCENT) k(ri) x RCR = 5 k = ROOM INDEX UF(total) Direct According to DIN EN Suspended SHRNOM = 1.25 C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

16 BEST TEST SERVICE SHENZHEN CO., LTD. Page 7 Of 16 ISOCANDELA DIAGRAM Test:U:12.V I:.712A P:8.94W PF:.9469 Lamp Flux: x1 lm NAME: DIM.: MFR.: EiKO TYPE:LED8WPAR28/NFL/83-DIM SPEC.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE: % % % % % % % 111 8% % VERTICAL(DEG) Imax:1586(H.5,V-1.) (At:C=67.5,Gamma=1.) UNIT: cd HORIZONTAL(DEG) C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

17 BEST TEST SERVICE SHENZHEN CO., LTD. Page 8 Of 16 AAI Figure Test:U:12.V I:.712A P:8.94W PF:.9469 Lamp Flux: x1 lm NAME: DIM.: MFR.: EiKO TYPE:LED8WPAR28/NFL/83-DIM SPEC.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE: Flux out:172.1 lm 3.281ft 1m 95.48,147.3fc 128,1586lx 1.399ft 42.65cm 6.562ft 2m 23.87,36.83fc 256.9,396.5lx 2.798ft 85.29cm 9.843ft 3m 1.61,16.37fc 114.2,176.2lx 4.197ft cm 13.12ft 4m 5.968,9.29fc 64.23,99.12lx 5.597ft 17.58cm 16.4ft 5m 3.819,5.894fc 41.11,63.44lx 6.996ft cm Height Eavg,Emax Angle:24.7deg Diameter Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance. C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

18 BEST TEST SERVICE SHENZHEN CO., LTD. Page 9 Of 16 ISOLUX DIAGRAM Test:U:12.V I:.712A P:8.94W PF:.9469 Lamp Flux: x1 lm NAME: DIM.: MFR.: EiKO TYPE:LED8WPAR28/NFL/83-DIM SPEC.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE: 18.' 9.'.' 9.' 18.' 22.5' 6.87m 18.' 5.5m 13.5' 4.12m 3%.4748lx.4411fc 5%.7914lx.7352fc 1% 1.583lx.147fc 3% 4.748lx.4411fc 5% 7.914lx.7352fc 9.' 2.75m 4.5' 1.37m.' m 4.5' 1.37m 9.' 2.75m 13.5' 4.12m 18.' 5.5m 22.5' 6.87m 5.5m 2.75m m 2.75m 5.5m MOUNTING HEIGHT: 33'(1.m) C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

19 BEST TEST SERVICE SHENZHEN CO., LTD. Page 1 Of 16 Average Luminance Table(CIBSE) Test:U:12.V I:.712A P:8.94W PF:.9469 Lamp Flux: x1 lm NAME: DIM.: MFR.: EiKO TYPE:LED8WPAR28/NFL/83-DIM SPEC.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE: Parameter description for average Luminance Symbol Value Unit Luminance in Azimuth Plane Bc refer Table 2 cd/sq.m. Intensity at angle Gamma in given azimuth plane I from data cd/klm Number of lamps N 1 Output of each lamp(initial lumens as specified) F lm Multiplying factor K 1 Luminous area in horizontal plane used in calculations A.1 sq.m. Angle to the downward vertical from light centre Gamma from data deg Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance G C plane(deg) deg Table 2. Average Luminance(cd/sq.m.) for defined C plane,gamma angle CIBSE Gamma Average Luminance Patch Luminance Category (deg) maximum calculated specified maximum maximum measured specified maximum Category 1 Category 2 Category 3 55 to 9 65 to 9 75 to Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories No match C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

20 BEST TEST SERVICE SHENZHEN CO., LTD. Page 11 Of 16 Average Luminance Table(CIBSE) Test:U:12.V I:.712A P:8.94W PF:.9469 Lamp Flux: x1 lm NAME: DIM.: MFR.: EiKO TYPE:LED8WPAR28/NFL/83-DIM SPEC.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE: Parameter description for average Luminance Symbol Value Unit Luminance in Azimuth Plane Bc refer Table 2 cd/sq.m. Intensity at angle Gamma in given azimuth plane I from data cd/klm Number of lamps N 1 Output of each lamp(initial lumens as specified) F lm Multiplying factor K 1 Luminous area in horizontal plane used in calculations A.1 sq.m. Angle to the downward vertical from light centre Gamma from data deg Table 1. Calculation parameters for determination of CIBSE LG3:21 Average Luminance G C plane(deg) deg Table 2. Average Luminance(cd/sq.m.) for defined C plane,gamma angle range (deg) 55 to 9 65 to 9 Average Luminance(cd/sq.m) Maximum Maximum limit for screen type & software category used measured Type I,II screen Type I,II screen Type III screen Type III screen Some neg.s'ware Only pos.s'ware Some neg.s'ware Only pos.s'ware Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits The luminaire satisifies the specified luminance criteria for Negative Software with Type I & II Screen(Good to Moderate treatment). C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

21 BEST TEST SERVICE SHENZHEN CO., LTD. Page 12 Of 16 Planar Illuminance Curve E(lx) 2 18 Planar Illuminance Curve MH = 1 m C/18 C9/ Distance(m) C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

22 BEST TEST SERVICE SHENZHEN CO., LTD. Page 13 Of 16 LUMINOUS DISTRIBUTION INTENSITY DATA Test:U:12.V I:.712A P:8.94W PF:.9469 Lamp Flux: x1 lm NAME: DIM.: MFR.: EiKO TYPE:LED8WPAR28/NFL/83-DIM SPEC.: SUR.: WEIGHT: SERIAL No.: PROTECTION ANGLE: Table--1 C(DEG) (DEG) UNIT: cd C Range: - 36DEG Test Date: Range: - 18DEG Interval: 1.DEG Test System:EVERFINE GO-R5_V2 SYSTEM V Test Distance:2.453m [K=1.]

23 I(cd) A1 A B12 B

24 d/h lm K = lx

25 F = 5 lm K =.7 Hcc =. m Hfc =. m Eave = 1 lx Pcc Pw Pfc N H=6 4 5 H= S(m2)

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT BEST TEST SERVICE SHENZHEN CO., LTD. Page 1 Of 16 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.V I:.459A P:4.982W PF:.944 Lamp Flux:278.299x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 55.86 lm/w MODEL NLL8

More information

Photometric and Electrical

Photometric and Electrical Photometric and Electrical Measurement and Test Report for LED Hong Kong Ltd. No.24, Walok Industrial Building, SanMei Street, FoTan New Territory Hong Kong Oct 17, 212 Product Name: 1.2M,2 24W LED Corrosion

More information

Photometric and Electrical

Photometric and Electrical Photometric and Electrical Measurement and Test Report for LED Hong Kong Ltd. No.24, Walok Industrial Building, SanMei Street, FoTan New Territory Hong Kong Oct 17, 212 Product Name: 1.2M,1 24W LED Corrosion

More information

IESNA LM-79: Measurement and Test Report for. Green Venture Group Ltd. Aug 02, 2012 ~~ _A BTR

IESNA LM-79: Measurement and Test Report for. Green Venture Group Ltd. Aug 02, 2012 ~~ _A BTR IESNA LM-79: 28 Measurement and Test Report for Green Venture Group Ltd. 14/F, Wing Hing Commercial Building, 16-18 Sutherland Street, Sheung Wan, Hong Kong Aug 2, 212 Product Name: V-Shape Light 12 Model

More information

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Centra!

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Centra! IESNA LM-79: 28 Measurement and Test Report for Green Creative Ltd. Room 126-7, New Victory House, 93-13 Wing Lok Street, Centra!, HONG KONG Sep 14, 212 ~ -~ j l I -1 Product Name: Model No~ --~-'---'~--

More information

IESNA LM-79: Measurement and Test Report for Venture Lighting International Aurora Road, Suite A, Solon, OH 44139,United states

IESNA LM-79: Measurement and Test Report for Venture Lighting International Aurora Road, Suite A, Solon, OH 44139,United states IESNA LM-79: 28 Measurement and Test Report for Venture Lighting International 32 Aurora Road, Suite A, Solon, OH 44139,United states Aug 14, 215 Product Name: LED corn bulb Model No: VL1-OR45-4E26-AE

More information

IESNA LM-79: Measurement and Test Report for Blackjack Lighting Kingston Dr.Buffalo Grove, IL Aug 14, 2015 (Renew: Nov 30, 2015)

IESNA LM-79: Measurement and Test Report for Blackjack Lighting Kingston Dr.Buffalo Grove, IL Aug 14, 2015 (Renew: Nov 30, 2015) IESNA LM-79: 28 Measurement and Test Report for Blackjack Lighting 2961 Kingston Dr.Buffalo Grove, IL 689 Aug 14, 215 (Renew: Nov 3, 215) Product Name: Wedge LED Chandelier Model No: WEG-29P-PC WEG-26C-PC

More information

IESNA LM-79: Measurement and Test Report for Blackjack Lighting Kingston Dr.Buffalo Grove, IL Jul 13, 2015.

IESNA LM-79: Measurement and Test Report for Blackjack Lighting Kingston Dr.Buffalo Grove, IL Jul 13, 2015. IESNA LM-79: 28 Measurement and Test Report for Blackjack Lighting 2961 Kingston Dr.Buffalo Grove, IL 689 Jul 13, 215 Product Name: Swirl LED Pendant Model No: 2SWL-S7P-SN Test Engineer: David Zhang Report

More information

IESNA LM-79: Measurement and Test Report for EIKO GLOBAL, LLC W 84th St, Shawnee, KS Nov 09, 2015 LED100WPT50KMOG-G6

IESNA LM-79: Measurement and Test Report for EIKO GLOBAL, LLC W 84th St, Shawnee, KS Nov 09, 2015 LED100WPT50KMOG-G6 IESNA LM-79: 28 Measurement and Test Report for EIKO GLOBAL, LLC 2322 W 84th St, Shawnee, KS 66227 Nov 9, 215 Product Name: Model No: LED HID REPLACEMENT LED1WPT5KMOG-G6 Test Engineer: David Zhang Report

More information

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC W 84th St, Shawnee, KS LED80WPT50KMOG-G6

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC W 84th St, Shawnee, KS LED80WPT50KMOG-G6 IESNA LM-79: 28 Measurement and Test Report for EiKO Global, LLC 2322 W 84th St, Shawnee, KS 66227 Product Name: Model No: LED HID REPLACEMENT LED8WPT5KMOG-G6 Test Engineer: David Zhang Report No.: BTR66.181.15.19.5

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT BEST TEST SERVICE SHENZHEN CO.,LTD Page 1 Of 14 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.V I:.1772A P:21.22W PF:.9967 Lamp Flux:846.758x1 lm SUR.:.12*.66 DATA OF LAMP PHOTOMETRIC DATA Eff: 39.9 lm/w

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT BEST TEST SERVICE SHENZHEN CO.,LTD Page 1 Of 14 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.V I:.3254A P:38.91W PF:.9967 Lamp Flux:2311.94x1 lm TYPE:1LCL-2LMH SUR.:.15*1.2 DATA OF LAMP PHOTOMETRIC DATA

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name...: Address...: Maxlite Inc. 12 York Ave,West Caldwell,NJ,USA Brand Name...: Maxlite Report No... : BTR66.181.16.38.28 Product Name...: Downlight Recessed Model

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name...: Blackjack lighting Address...: 1553 Barclay Blvd. Buffalo Grove, IL 689 Brand Name...: Blackjack lighting Report No... : BTR66.181.16.5.31 Product Name...:

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name... : Blackjack lighting Address... : 1553 Barclay Blvd. Buffalo Grove, IL 689 Brand Name...: Blackjack lighting Report No.... : BTR66.181.15.35.1 Product Name...:

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name... : Blackjack lighting Address... : 1553 Barclay Blvd. Buffalo Grove, IL 689 Brand Name...: Blackjack lighting Report No.... : BTR66.181.15.4.53 Product Name...:

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name...: Address...: Maxlite Inc. 12 York Ave,West Caldwell,NJ,USA Brand Name...: Maxlite Report No... : BTR66.181.16.38.3 Product Name...: Downlight Recessed Model

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name... : Blackjack lighting Address... : 1553 Barclay Blvd. Buffalo Grove, IL 689 Brand Name...: Blackjack lighting Report No.... : BTR66.181.15.35.3 Product Name...:

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name...: Address...: Maxlite Inc. 12 York Ave,West Caldwell,NJ,USA Brand Name...: Maxlite Report No... : BTR66.181.16.38.27 Product Name...: Downlight Solid State Retrofit

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name...: Address...: Maxlite Inc. 12 York Ave,West Caldwell,NJ,USA Brand Name...: Maxlite Report No... : BTR66.181.16.38.29 Product Name...: Downlight Recessed Model

More information

IESNA LM-79 TEST REPORT

IESNA LM-79 TEST REPORT IESNA LM-79 TEST REPORT Applicant s name...: Blackjack lighting Address...: 1553 Barclay Blvd. Buffalo Grove, IL 689 Brand Name...: Blackjack lighting Report No... : BTR66.181.16.5.32 Product Name...:

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 15 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:12.V I:.4262A P:5.22W PF:.9821 Freq:6.1Hz Lamp Flux:6293.9x1 lm NAME: BDPE24DUA-5WB-PKBWA DATA OF LAMP

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:99.7V I:.3739A P:36.93W PF:.994 Freq:6.1Hz Lamp Flux:5315.62x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 143.96 lm/w MODEL MY-BL45ENLE9 Imax(cd) 1698 S/MH(C/18)

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 13 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:23.29V I:.6569A P:147.29W PF:.9737 Freq:5.Hz Lamp Flux:14.811x168 lm NAME: SPS154-HL15B-168DW-12 SUR.:72*55mm

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 13 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:23.12V I:.6544A P:146.61W PF:.9736 Freq:5.Hz Lamp Flux:18.8x168 lm NAME: SPS154-HL15B-168DW-9 SUR.:72*55mm

More information

FCL6 inch LED Downlight

FCL6 inch LED Downlight GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 FCL6 inch LED Downlight FCL6-2W Light Output Ratio: 1.% Luminaire Power: 22.42 W SHR Nominal: 1.25 Calculated using the TM5 SHR Maximum: 1.25 fine grid

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 13 LUMINAIRE PHOTOMETRIC TEST REPORT NAME: 95-65 SPEC.:5W DIM.: 1566*86*8(MM) SERIAL No.:1 Shielding Angle:12 DATA OF LAMP PHOTOMETRIC DATA Eff: 12.2

More information

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 16 LUMINAIRE PHOTOMETRIC TEST REPORT

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 16 LUMINAIRE PHOTOMETRIC TEST REPORT EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 16 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:23.V I:.675A P:15.W PF:.9658 Lamp Flux:1831.3x1 lm NAME: LHB1 15 SPEC.:5K Ra7 4*13DEG TYPE:15W DIM.: 1.18*.14..12

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT Page 1 Of 13 VOLTEX SYSTEM TEST REPORT LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:229.6V I:.4485A P:11.9W PF:.9894 Lamp Flux:11996.6x1 lm NAME: HBL-1W-CW TYPE:1W SPEC.:5K Ra7 12DEG DIM.:.38*.38*.12 SUR.:.23*.23

More information

PARAGON GONIOPHOTOMETERS SYSTEM TEST REPORT M2B-CN,NA7, MY PHUOC 2 IZ, BEN CAT-BINH DUONG

PARAGON GONIOPHOTOMETERS SYSTEM TEST REPORT M2B-CN,NA7, MY PHUOC 2 IZ, BEN CAT-BINH DUONG Page 1 Of 13 LUMINAIRE PHOTOMETRIC TEST REPORT Test:U:22.2V I:.7966A P:.4W PF:1. Lamp Flux:8.58x1 lm NAME: DÈN CHÔNG NÔ HIÊU EEW SPEC.: RANGDONG W/22V/5Hz MFR.: PARAGON TYPE:BCD_RD DIM.: PHIX31 SUR.:PHI14X14

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 12 LUMINAIRE PHOTOMETRIC TEST REPORT DATA OF LAMP PHOTOMETRIC DATA Eff: 67.14 lm/w MODEL LY4S 3K Imax(cd).6 S/MH(C/18) 1.11 NOMINAL POWER(W) LOR(%)

More information

IESNA LM79: 2008 Photometric Test Report

IESNA LM79: 2008 Photometric Test Report IESNA LM79: 28 Photometric Test Report Photometric Testing and Evaluation in Accordance with LM 79-28 Report Prepared For David Delgado Manger Applications and Certification MaxLite Description of Sample:

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 14 LUMINAIRE PHOTOMETRIC TEST REPORT DATA OF LAMP PHOTOMETRIC DATA Eff: 155.35 lm/w MODEL ASD-WHB-4D95PRM Imax(cd) 6586 S/MH(C/18) 1.29 NOMINAL POWER(W)

More information

galeria LED track Engineering & Photometric Data

galeria LED track Engineering & Photometric Data LUMINAIRE PHOTOMETRIC TEST REPORT DATA OF LAMP PHOTOMETRIC DATA Eff: 64.91 lm/w MODEL SHARP Imax(cd) 581 S/MH(C/18).37 NOMINAL POWER(W) 16 LOR(%) 89.9 S/MH(C9/27).34 RATED VOLTAGE(V) 22 TOTAL FLUX(lm)

More information

ALINEA COMPATIBLE WITH LWES-FL2216CCT VDC-IP20 LWES-FL2216CCT VDC-IP20 AVAILABLE LED SOURCE TYPE CCT DIM/WARM K 33WATT/ METER 24V

ALINEA COMPATIBLE WITH LWES-FL2216CCT VDC-IP20 LWES-FL2216CCT VDC-IP20 AVAILABLE LED SOURCE TYPE CCT DIM/WARM K 33WATT/ METER 24V LWES-FL2216CCT-48-24VDC-IP2 RIGID PCB LED SOURCE TYPE CCT CRI LOAD VOLTAGE SMD 2216 DIM/WARM 3-21K 94CRI 33WATT/ METER 24V LUMEN/METER 1599.1LM/M LUMEN/WATT 48.45LM/W OPTIC CONSTRUCTION COMPATIBILITY DIMENSIONS

More information

convex LED ceiling Engineering & Photometric Data

convex LED ceiling Engineering & Photometric Data LUMINAIRE PHOTOMETRIC TEST REPORT DATA OF LAMP PHOTOMETRIC DATA Eff: 72.1 lm/w MODEL CTTIZEN Imax(cd) 518.5 S/MH(C/18) 1.14 NOMINAL POWER(W) 15 LOR(%) 9.8 S/MH(C9/27) 1.27 RATED VOLTAGE(V) 22 TOTAL FLUX(lm)

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT LUMINAIRE PHOTOMETRIC TEST REPORT DATA OF LAMP Imax(cd) 648.7 S/MH(C/18) 1.23 MODEL CLUB SP1 EFFICIENCY(%) 1. S/MH(C9/27) 1.5 NOMINAL POWER(W) 24 TOTAL FLUX(lm) 1123.8 Voltage(V) 22.6 RATED VOLTAGE(V)

More information

THE FIRST AFFORDABLE HIGH- PERFORMANCE FULL SPECTRUM LED GROW LIGHT IN THE WORLD THE ÆONLUX 1K2.0

THE FIRST AFFORDABLE HIGH- PERFORMANCE FULL SPECTRUM LED GROW LIGHT IN THE WORLD THE ÆONLUX 1K2.0 THE FIRST AFFORDABLE HIGH- PERFORMANCE FULL SPECTRUM LED GROW LIGHT IN THE WORLD THE ÆONLUX 1K2.0 2 THE ÆONLUX 1K2.0 With ÆONLUX Lighting, you ll reduce costs, speed your time to market, and deliver high

More information

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 10 STREETLIGHT PHOTOMETRIC TEST REPORT

EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 10 STREETLIGHT PHOTOMETRIC TEST REPORT EVERFINE GONIOPHOTOMETERS SYSTEM TEST REPORT Page 1 Of 1 STREETLIGHT PHOTOMETRIC TEST REPORT DATA OF LAMP PHOTOMETRIC DATA Eff: 84.96 lm/w MODEL Imax(cd) 265 street_up(%). NOMINAL POWER(W) 35 LOR(%) 1.

More information

STREETLIGHT PHOTOMETRIC TEST REPORT

STREETLIGHT PHOTOMETRIC TEST REPORT Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 Of 1 STREETLIGHT PHOTOMETRIC TEST REPORT Test:U:28.66V I:1.399A P:4.9W PF:1. Freq:Hz Lamp Flux:5279.71x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 131.68

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

STREETLIGHT PHOTOMETRIC TEST REPORT

STREETLIGHT PHOTOMETRIC TEST REPORT Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 Of 1 STREETLIGHT PHOTOMETRIC TEST REPORT Test:U:26.22V I:.5861A P:15.37W PF:1. Freq:Hz Lamp Flux:1843.45x1 lm DATA OF LAMP PHOTOMETRIC DATA Eff: 119.94

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT LM-79-08 Test Report For Model Different: All construction and rating are the same, except CCT Test & Report By: Review By: Sean Zhuo Engineer: Sean Zhuo Date: Apr.24,2015 Manager: Tommy Liang Note: This

More information

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006 LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP35AUT550BPCMA Test & Report By: Sean Zhuo Engineer:

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8030M57-A Representative (Tested) Model: LED-8030M57-A Model Different

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8036M40-A Representative (Tested) Model: LED-8036M40-A Model Different

More information

V(B) Range:-60-60DEG V(B) Interval: 2.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V Test Distance:8.100m [K=1.

V(B) Range:-60-60DEG V(B) Interval: 2.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V Test Distance:8.100m [K=1. Floodlight Summary: Report based on lamp delivering 1 lumens. Maximum Intensity (Luminaire orientation as tested.) 1712.7 cd per klm.. degrees vertical. degrees horizontal Beam Spread At 1% of Imax 88.3V

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8050M50-HV Representative (Tested) Model: LED-8050M50-HV Model Different

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8029E40-A LED-8029M40-A Remark : The suffix of the model name E stand

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-2000LM-3000K Representative (Tested) Model: RPT-LEDBIAX-2000LM-3000K

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8029E57-A LED-8029M57-A Remark : The suffix of the model name E stand

More information

V(B) Range:-60-60DEG V(B) Interval: 2.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V Test Distance:8.100m [K=1.

V(B) Range:-60-60DEG V(B) Interval: 2.0DEG Test System:EVERFINE GO-2000B_V1 SYSTEM V Test Distance:8.100m [K=1. Floodlight Summary: Report based on lamp delivering 1 lumens. Maximum Intensity (Luminaire orientation as tested.) 21665.9 cd per klm.. degrees vertical. degrees horizontal Beam Spread At 1% of Imax 2.1V

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED11WA19/300/827K-GU24-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED15WA21/300/830K-GU24-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA LM-79-08 Test Report For MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA OUTDOOR FULL-CUTOFF WALL-MOUNTED AREA LUMINAIRES Model name(s): BP45AUT5XXBPM0 BP45AUT5XXWPM0 Remark: The

More information

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA LM-79-08 Test Report For MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA Four-Foot Linear Replacement Lamps Model name(s): MT8Z04 Representative (Tested) Model:

More information

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Luminaire Model name(s): LED-8050M50 Representative (Tested) Model: LED-8050M50 Model Different

More information

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0.

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0. LED Wall-PACK/Flood Light DataSheet Cat# 71391 Wet Locations Use RoHS QPL ID # PSQKCNWM Model: 71391 Input Voltage 100-277VAC Input Current 0.5A @100V / 0.2A @277V Input Power 28 W OVERALL LAMP PARAMETERS

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED11WA19/300/840K-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) SANHUI INDUSTRY ZONE CUNWEI VILLAGE HENGLI TOWN DONGGUAN GUANGDONG 523000 CN Outdoor Wall-Mounted Area

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006 LM-79-08 Test Report For MAXLITE INC (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): PTD100UT341SMxxx Representative (Tested)

More information

Rotation Luminaire Goniophotometer (LSG-1600B) Brochure. Global Office of Lisun Electronics Inc.

Rotation Luminaire Goniophotometer (LSG-1600B) Brochure. Global Office of Lisun Electronics Inc. Rotation Luminaire Goniophotometer (LSG-16B) Brochure Global Office of Lisun Electronics Inc. http://www.lisungroup.com Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678

More information

LIGHT EFFICIENT DESIGN, LLC

LIGHT EFFICIENT DESIGN, LLC LM-79-08 Test Report For LIGHT EFFICIENT DESIGN, LLC (Brand Name: N/A) 188 S.Northwest Highway, Cary, IL60013, USA LED Luminaires Model name(s): LED-7320-40K-G2 Representative (Tested) Model: LED-7320-40K-G2

More information

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For HOCAN GROUP CO.,LTD (Brand Name: SEPICN LED LIGHTING) Rm.1902, Easey Comm. Bldg., 253-261 Hennessy Road,Wanchai, Hong Kong Direct Linear Ambient Luminaires Low-bay Luminaires for

More information

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS LED Wall-PACK/FloodLight DataSheet Cat# 71393 Model: RoHS Wet Locations Use 71393 Input Voltage 100-277VAC Input Current 0.69A @120V / 0.31A @277V Input Power 79 W Power Factor PF 0.95 OVERALL LAMP PARAMETERS

More information

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED) LM-79-08 Test Report For SNC OPTO ELECTRONIC CO.,LTD (Brand Name: SNC LED) Block 6,Zhengdaan Industry Park,No.172,Xiangshan Road,Luotian Village, SongGang Town,Baoan District,Shenzhen Replacement Lamps

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. LED LAMP Model name(s): TLFLF220XYYZZ Remark:The letter

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. LED LAMP Model name(s): TLFLF80XYYZZ Remark:The letter

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E57-A LED-8038-DL-E27-A Remark: The two models are the same

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8046M57-A LED-8046-DL-E40-A Remark: The two models are the same

More information

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black Catalog Number 71376 UPC Number 601986713764 Description LED Bullet Flood Light 30 W 2300 Lumens Features Cree CXA LED s, CRI: 70+ Voltage: 120-277VAC Isolated Driver Compartment for Optimal Thermal Management

More information

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For HOCAN GROUP CO.,LTD (Brand Name: SEPICN LED LIGHTING) Rm.1902, Easey Comm. Bldg., 253-261 Hennessy Road,Wanchai, Hong Kong Direct Linear Ambient Luminaires Low-bay Luminaires for

More information

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED) LM-79-08 Test Report For SNC OPTO ELECTRONIC CO.,LTD (Brand Name: SNC LED) Block 6,Zhengdaan Industry Park,No.172,Xiangshan Road,Luotian Village, SongGang Town,Baoan District,Shenzhen Replacement Lamps

More information

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503 LM-79-08 Test Report For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): IGTWP-0301550 (5000K) Model Difference:

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8024M40-A LED-8024-CW-E40-A Remark: The two models are the same

More information

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black Catalog Number 71372 UPC Number 601986713726 Description LED Bullet Flood Light 1 LED 800 Lumen Features Cree CXA LED s, CRI: 70+ Voltage: 120-277VAC Isolated Driver Compartment for Optimal Thermal Management

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8046M40-A LED-8046-CW-E40-A Remark: The two models are the same

More information

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India IES LM-79-08 MEASUREMENT AND TEST REPORT For Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida 201305 UP India Test Model: L14EH80-W/HB/50K Report Type: Electrical and Photometric

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8033E40-A LED-8033-CW-E27-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8033E57-A LED-8033-DL-E27-A Remark: The two models are the same

More information

LIGHT EFFICIENT DESIGN

LIGHT EFFICIENT DESIGN LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E40-A LED-8038-CW-E27-A Remark: The two models are the same

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E30-A LED-8038-NW-E27-A Remark: The two models are the same

More information

Soraa Internal Report: IES LM79 08

Soraa Internal Report: IES LM79 08 PRELIMINARY Soraa Internal Report: IES LM79 08 Test results reported for: Part Number: SM16-09-36D-930-03 Soraa MR16, GU5.3/12V, 3000K, 95CRI, 9W, 36degree Relevant Standards IES LM-79 ANSI C78.377 IES

More information

INDEPENDENT TEST LABORATORY REPORT No A

INDEPENDENT TEST LABORATORY REPORT No A Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were)

More information

T8 4ft 5000K EazyLux EZ8450D7R07

T8 4ft 5000K EazyLux EZ8450D7R07 PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08 Sample Tested T8 4ft 5000K EazyLux EZ8450D7R07 Prepared for: James Pan, Ph.D. Luxul Technology, Inc. 2905 Stender Way, Suite 22 Santa Clara, CA 95054 Phone:

More information

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA LM-79-08 Test Report For Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 1130SG-35T Remark:

More information

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were)

More information

LUMINAIRE PHOTOMETRIC TEST REPORT

LUMINAIRE PHOTOMETRIC TEST REPORT LUMINAIRE PHOTOMETRIC TEST REPORT DATA OF LAMP Imax(cd) 5937 S/MH(C/18).22 MODEL v13 EFFICIENCY(%) 1. S/MH(C9/27).32 NOMINAL POWER(W) 28 TOTAL FLUX(lm) 1337.1 Voltage(V) 234.3 RATED VOLTAGE(V) 234 EFFICIENCY(lm/W)

More information

Lisun Electronics Inc. Tel:+86(21)

Lisun Electronics Inc.   Tel:+86(21) Report No.: Test Time: 2013-11-28 15:27 Luminaire Property Page 1 of 17 Pages Luminaire Manufacturer: One Electrical Co.,ltd Luminaire Category: OE-LED-PANEL22 Luminaire Description: 22W Round LED Panel

More information

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were)

More information

Soraa Internal Report: IES LM79-08

Soraa Internal Report: IES LM79-08 PRELIMINARY Soraa Internal Report: IES LM79-08 Test results reported for: Customer Reference P/N: SR111-18-08D-830-03 Manufacturing P/N: SR111-18-08D-830-03 Soraa AR111, G53/12V, 3000K, 80CRI, 18.5W, 8degree

More information

Lisun Electronics Inc. Tel:+86(21)

Lisun Electronics Inc.  Tel:+86(21) Report No.: Test Time: 2013-11-28 14:48 Luminaire Property Page 1 of 17 Pages Luminaire Manufacturer: One Electrical Co.,ltd Luminaire Category: OE-LED-COB-30 Luminaire Description: 30W COB LED Downlight

More information

Report of Test LLIA A-R02*

Report of Test LLIA A-R02* Report of Test LLIA000762-006A-R02* *This test report supersedes test report LLIA000762-006A-R01 each. Two Osram Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL13048-001A CR4T-790L-27K-12-E26GU24 Date: 08/22/18 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy Lehrmann

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09173-004B IG-NM-5S-A-30K-UL-WH xxx Date: 09/21/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Zongjie

More information