LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

Size: px
Start display at page:

Download "LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923"

Transcription

1 LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA Model(s): Sylvania LED10A19/F/827/RP (Sample 28) 13 June 2013 This test report presents the results of measurements performed on the product Sylvania LED10A19/F/827/RP (Sample 28) in accordance with LM Electrical and Photometric Measurements of Solid-State Lighting Products. Test Personnel: J. Evans D. Dionne Test Date: 6/13/2013 (Goniophotometry) 6/13/2013 (Integrating Sphere) 6/14/2013 NVLAP Signatory: X Mark B. Sapcoe Principal Engineer Mark B. Sapcoe Laboratory: Report Number: Analytics & Metrology NVLAP Code: OSRAM SYLVANIA INC. 71 Cherry Hill Drive Beverly, MA Voice: Fax: mark.sapcoe@sylvania.com Associated Request Number(s): FOR THE SCOPE OF ACCREDITATION UNDER NVLAP LAB CODE This report does not imply product certification, approval or endorsement by NVLAP, NIST or any agency of the federal government. Page 1 of 12

2 General Information Product tested Sylvania LED10A19/F/827/RP (Sample 28) Purpose of test This test report is prepared on behalf of OSRAM SYLVANIA INC. in accordance with American National Standards Institute standards, Illumination Engineering Society of North America Lighting Methods and International Commission on Illumination (CIE) publications listed below: IESNA LM-79-08, Approved Method for the Electrical and Photometric Testing of Solid-State Lighting Products IESNA LM , Guide for the Selection, Care and Use of Electrical Instruments in the Photometric Laboratory CIE Publication No , Method of Measuring and Specifying the Color Rendering of Light Sources. The objective is to demonstrate compliance of the product evaluated to LM Electrical and Photometric Measurements of Solid-State Lighting Products. Laboratory Accreditation Analytics & Metrology (ANM) is a component of OSRAM SYLVANIA, Corporate Technology, Technical Services & Support. ANM is located at 71 Cherry Hill Drive, Beverly, MA ANM is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), Energy Efficient Lighting (EEL) program. NVLAP is a division of the National Institute of Standards and Technology. ANM NVLAP Laboratory Code is Page 2 of 12

3 Test Equipment Goniometry Equipment Manufacturer Model No. Serial No. Calibration (Cycle in years) Power Supply Kikusui PCR2000L GM Not required Power Meter Yokogawa WT V /6/13 (1) Multimeter/Data Acquisition System Keithley /18/13 (3) 10 Polar Goniometer OS None None 02/14/13 (1) Integrating sphere radiometry Equipment Manufacturer Model No. Serial No. Calibration (Cycle in years) Integrating Sphere 1.5 Meter Dia. B Not required Spectrometer Instrument Systems CAS 140 CT /08/2012 (1) Self Absorption Meter Keithley /17/2013 (3) Lumen Standards OSI , /08/2012 (1) Spectral Standard OSI SB # /01/2008 (5) A.C. Power Supply Kikusui PCR500M MD Not required A.C. Line Conditioner Elgar 5000B 4924 Not required Power Meter Yokogawa WT C /17/2013 (1) D.C. Power Supply Hewlett Packard 6030A 3544A Not required VDC Meter Keithley /17/2013 (3) ADC Meter Keithley /17/2013 (3) Current Shunt Guildline 9230/ /08/2013 (1) Calibration intervals are based on critical evaluations of equipment and standards behavior as per ANS/ISO/IEC 17025:2005(E) All calibrations are directly traceable to a NMI (NIST) through an unbroken chain of calibrations or comparisons. Page 3 of 12

4 Procedure Goniometry The lamp was operated base up. The lamp reference plane was located at the center of the lamp goniometer at a test distance of 10 feet from the detectors. The lamp was operated at an input voltage of 120VAC supplied by a four contact connection. The lamp was stabilized per the criteria of LM-79 prior to the measurement. Nine (9) vertical scans were taken due to symmetry of the source output. Color uniformity was measured at two horizontal angles, 0 and 90. Total operating time prior to measurement is approximately 1 hour. Ambient temperature during testing was maintained at 25 C ± 1 C. Integrating Sphere Radiometry Calibration of the sphere-spectroradiometer system was performed using the flux calibration lamp. The lamp was mounted in the sphere base up. The lamp was operated at 120VAC. The lamp was stabilized per the criteria of LM-79 prior to the measurement. After the lamp was stabilized inside the sphere, electrical and spectrophotometric measurements were simultaneously performed. Ambient temperature during testing was maintained at 25 C ± 1 C. Page 4 of 12

5 Measured and Derived Performance Parameters Integrating Sphere Values Integrating Sphere Values Voltage /V Current /A Special Color Rendering Wattage /W R1 80 Power Factor R2 89 ITHD 49.72% R3 96 Lumens 903 R4 80 Efficacy /LPW 89.0 R5 79 x R6 85 y R7 84 u R8 62 v R9 14 Duv R10 74 CCT /K 2776 R11 77 CRI 82 R12 70 R9 14 R13 81 S/P 1.21 R14 98 T amb / C 24.5 Goniophotometer Values Goniometric Values Voltage /V Current /A Wattage /W Power Factor ITHD 49.25% Lumens 905 Efficacy /LPW 89.1 T amb / C 24.6 Page 5 of 12

6 Absolute Spectral Radiant Flux 2.00E-02 W/nm 1.80E E E E E E E E E E nm Page 6 of 12

7 Absolute Spectral Radiant Flux Absolute Spectral Flux nm W/nm nm W/nm nm W/nm nm W/nm nm W/nm E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E-04 Page 7 of 12

8 Spatial Distribution Photometry Manufacturer: Sylvania Lamp: LED10A19/F/827/RP Lamp Output: 905 lumens Max Candela: at Horizontal: 180, Vertical: 2 Input Wattage: Luminous Opening: Vertical Cylinder (Dia : 2.18", H: 1.06") Test: Test Date: 6/13/2013 Test Lab: Osram Sylvania ANM NA Photometry : Type C Lumens Per Zone Zone Lumens % Total Zone Lumens % Total % % % % % % % % % % % % % % % % % % % % % % % % % % % % % % % % % % % % Zonal Lumen Summary Zone Lumens % Luminaire % % % % % % % % % Page 8 of 12

9 Spatial Distribution Photometry (continued) Candela Table - Type C Candela Table - Type C Page 9 of 12

10 Spatial Color Deviation (Goniospectroradiometric Determination) Average Weighted u', v' Horizontal Vertical Spatial u', v' Du'v' Page 10 of 12

11 Compliance to Specification for Chromaticity of Solid State Lighting Products 0.46 Nominal CCT Categories ANSI_NEMA_ANSLG C Planckian locus 2700 K 3000 K K K 4500 K y K 5000 K K 3000 K 2500 K K 5000 K K 7000 K x Page 11 of 12

12 Page 12 of 12

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 LM 79 08 Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923 Model(s) This test report presents the results of measurements performed on the product Spectrum Lighting SX1605RDLED18W35KE1/SM/OP

More information

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA. LM-79-08 Test Report For REMPHOS TECHNOLOGIES LLC (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA LED Lamp Model name(s): RPT-LEDBIAX-2000LM-3000K Representative (Tested) Model: RPT-LEDBIAX-2000LM-3000K

More information

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard LM-79 Test Report Test Request Number 0980103 Lamp specifics: Luminaire Used: EAMD0R541L1CBLCK Rated Watts Voltage: 91 Watts Lamp Type: Type Type V Round V Round Sym w Evolve Sym w LED Rated Orientation

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8030M57-A Representative (Tested) Model: LED-8030M57-A Model Different

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8036M40-A Representative (Tested) Model: LED-8036M40-A Model Different

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8050M50-HV Representative (Tested) Model: LED-8050M50-HV Model Different

More information

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006 LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP35AUT550BPCMA Test & Report By: Sean Zhuo Engineer:

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8029E40-A LED-8029M40-A Remark : The suffix of the model name E stand

More information

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT LM-79-08 Test Report For Model Different: All construction and rating are the same, except CCT Test & Report By: Review By: Sean Zhuo Engineer: Sean Zhuo Date: Apr.24,2015 Manager: Tommy Liang Note: This

More information

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Lamp Model name(s): LED-8029E57-A LED-8029M57-A Remark : The suffix of the model name E stand

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL 60013 LED Luminaire Model name(s): LED-8050M50 Representative (Tested) Model: LED-8050M50 Model Different

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E57-A LED-8038-DL-E27-A Remark: The two models are the same

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8046M57-A LED-8046-DL-E40-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8024M40-A LED-8024-CW-E40-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8033E40-A LED-8033-CW-E27-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8033E57-A LED-8033-DL-E27-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006 LM-79-08 Test Report For MAXLITE INC (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): PTD100UT341SMxxx Representative (Tested)

More information

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA LM-79-08 Test Report For MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA Four-Foot Linear Replacement Lamps Model name(s): MT8Z04 Representative (Tested) Model:

More information

LIGHT EFFICIENT DESIGN

LIGHT EFFICIENT DESIGN LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E40-A LED-8038-CW-E27-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA LM-79-08 Test Report For MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA OUTDOOR FULL-CUTOFF WALL-MOUNTED AREA LUMINAIRES Model name(s): BP45AUT5XXBPM0 BP45AUT5XXWPM0 Remark: The

More information

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8038E30-A LED-8038-NW-E27-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013. LM-79-08 Test Report For LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013 LED Luminaires Model name(s): LED-8046M40-A LED-8046-CW-E40-A Remark: The two models are the same

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING) LM-79-08 Test Report For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD (Brand Name: GI LED LIGHTING) 4th floor, building 2, Zone 2, Hong Hua Ling Industrial Park, Liu xian Block,Nan Shan District, Shenzhen,

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) SANHUI INDUSTRY ZONE CUNWEI VILLAGE HENGLI TOWN DONGGUAN GUANGDONG 523000 CN Outdoor Wall-Mounted Area

More information

LIGHT EFFICIENT DESIGN, LLC

LIGHT EFFICIENT DESIGN, LLC LM-79-08 Test Report For LIGHT EFFICIENT DESIGN, LLC (Brand Name: N/A) 188 S.Northwest Highway, Cary, IL60013, USA LED Luminaires Model name(s): LED-7320-40K-G2 Representative (Tested) Model: LED-7320-40K-G2

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report NVLAP Lab Code 77- Report Number: Model: PL-1 BXSPCxx2LGE3K-xxxxxx w/xa-sp1bls or XSPCxx2LGE3 Date: 8/8/21 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

More information

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0.

Wet Locations Use. RoHS. Model: VAC / 28 W PF LM 93 LM/W. Alluminium + Tempered Glass 24-45VDC 0. LED Wall-PACK/Flood Light DataSheet Cat# 71391 Wet Locations Use RoHS QPL ID # PSQKCNWM Model: 71391 Input Voltage 100-277VAC Input Current 0.5A @100V / 0.2A @277V Input Power 28 W OVERALL LAMP PARAMETERS

More information

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Report Number: Model: PL07003-001A RUL-HT-5ME-C-40K-12-UF-N-ES-K2 Date: 12/16/2015 Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report Prepared For: Michael Hash

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09173-004B IG-NM-5S-A-30K-UL-WH xxx Date: 09/21/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Zongjie

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. LED LAMP Model name(s): TLFLF220XYYZZ Remark:The letter

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. LED LAMP Model name(s): TLFLF80XYYZZ Remark:The letter

More information

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503 LM-79-08 Test Report For IGT LIGHTING INC. 3755 Lincoln St. Suite B, Riverside, CA 92503 Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires Model name(s): IGTWP-0301550 (5000K) Model Difference:

More information

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED) LM-79-08 Test Report For SNC OPTO ELECTRONIC CO.,LTD (Brand Name: SNC LED) Block 6,Zhengdaan Industry Park,No.172,Xiangshan Road,Luotian Village, SongGang Town,Baoan District,Shenzhen Replacement Lamps

More information

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED) LM-79-08 Test Report For SNC OPTO ELECTRONIC CO.,LTD (Brand Name: SNC LED) Block 6,Zhengdaan Industry Park,No.172,Xiangshan Road,Luotian Village, SongGang Town,Baoan District,Shenzhen Replacement Lamps

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL08239-001A LN4-34L-40K-xxx Date: 05/13/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Jonathan Vollers

More information

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For HOCAN GROUP CO.,LTD (Brand Name: SEPICN LED LIGHTING) Rm.1902, Easey Comm. Bldg., 253-261 Hennessy Road,Wanchai, Hong Kong Direct Linear Ambient Luminaires Low-bay Luminaires for

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL13048-001A CR4T-790L-27K-12-E26GU24 Date: 08/22/18 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy Lehrmann

More information

Report of Test LLIA A-R02*

Report of Test LLIA A-R02* Report of Test LLIA000762-006A-R02* *This test report supersedes test report LLIA000762-006A-R01 each. Two Osram Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous

More information

Report of Test LLIA A-R01*

Report of Test LLIA A-R01* Report of Test LLIA000849-002A-R01* *This test report supersedes test report LLIA000849-002A One Osram Optotronic OTi 30/120-277/1A0 DIM L LED driver. Total Light Output Luminaire Power Luminous Efficacy

More information

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO.,LTD. (Brand Name: SEPICN LED LIGHTING) LM-79-08 Test Report For HOCAN GROUP CO.,LTD (Brand Name: SEPICN LED LIGHTING) Rm.1902, Easey Comm. Bldg., 253-261 Hennessy Road,Wanchai, Hong Kong Direct Linear Ambient Luminaires Low-bay Luminaires for

More information

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT) LM-79-08 Test Report For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD (Brand Name: THAILIGHT) Sanhui Ind. Area, Cunwei, Hengli, Dongguan, China. Architectural Flood and Spot Luminaires Model name(s):

More information

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG Customer Company & Address: GREEN CREATIVE ADD: Room 1206-7 New Victory House, 93-103 Wing Lok Street, Central, HONG KONG Contact Person: Guillaume Vidal Telephone: +86 21-62320308 Email address: guillaume@gc-lighting.com

More information

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS

Wet Locations Use VAC / 79 W PF LM 92 LM/W. Alluminium + Tempered Glass 25-42VDC 1.95A 88% CXA PCS LED Wall-PACK/FloodLight DataSheet Cat# 71393 Model: RoHS Wet Locations Use 71393 Input Voltage 100-277VAC Input Current 0.69A @120V / 0.31A @277V Input Power 79 W Power Factor PF 0.95 OVERALL LAMP PARAMETERS

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL06624-001A VG-A-xx-5W-A-57K-UL w/ VG-PSSV Date: 08/20/2015 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000762-003A Catalog Number: MLS3-I/D-HO/HO-K40-4-X-WSOP/LOH-X-XXX each. Two Osram Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous Efficacy

More information

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Osram Sylvania 200 Ballardvale Street Wilmington, Mass Report No: L071407402 Date: 7/30/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L071407402 Report Prepared For: Osram Sylvania 200 Ballardvale

More information

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260 PHOTOMETRIC TESTING & EVALUATION Sample Tested Man-D-Tec UNILED-12-4K Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260 Phone: 480-998-0325 Technical Report Number 70150753 August 8, 2017

More information

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black Catalog Number 71376 UPC Number 601986713764 Description LED Bullet Flood Light 30 W 2300 Lumens Features Cree CXA LED s, CRI: 70+ Voltage: 120-277VAC Isolated Driver Compartment for Optimal Thermal Management

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000930-001A Catalog Number: AR300-D-MO-K40-80--4-XX-LOH-XXXX-120 One Osram Optotronic OTi 30/120-277/1A0 DIM L LED driver 120.0Vac, 60.00Hz, 0.1556A, 18.56W, 0.994PF, 5.2%THD(i) Total

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000930-002A Catalog Number: AR300-D-HO-K40-80--4-XX-LOH-XXXX-120 One Osram Optotronic OTi 30/120-277/1A0 DIM L LED driver 120.0Vac, 60.00Hz, 0.2331A, 27.89W, 0.997PF, 5.9%THD(i) Total

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000901-044A One ERP ESP050W-1200-42 LED driver 120.0Vac, 60.00Hz, 0.3999A, 47.20W, 0.984PF, 11.8%THD(i) Total Light Output Luminaire Power Luminous Efficacy Performance Summary 3548

More information

T8 4ft 5000K EazyLux EZ8450D7R07

T8 4ft 5000K EazyLux EZ8450D7R07 PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08 Sample Tested T8 4ft 5000K EazyLux EZ8450D7R07 Prepared for: James Pan, Ph.D. Luxul Technology, Inc. 2905 Stender Way, Suite 22 Santa Clara, CA 95054 Phone:

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000676-006A Catalog Number: ML3WL-I/D-HO/HO-K40-4-X-LOH/LOH-X-X-UNV Two Osram Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous Efficacy Performance

More information

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black Catalog Number 71372 UPC Number 601986713726 Description LED Bullet Flood Light 1 LED 800 Lumen Features Cree CXA LED s, CRI: 70+ Voltage: 120-277VAC Isolated Driver Compartment for Optimal Thermal Management

More information

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W Customer Company & Address: MaxLite ADD: 12 York Ave, West Caldwell, NJ 07006 Contact Person: Francisco Garza Telephone: 973-244-7300x142 Telephone: fgarza@maxlite.com Manufacturer: Country of Origin:

More information

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146,

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146, Photometric Test Report Relevant Standards IES LM-79-2008 Prepared For MaxLite Inc 0 York Avenue, West Caldwell, NJ 07006 Ramesh Raghavan, 973-244-7300 x46, rraghavan@maxlite.com Catalog Number BLHE-223DU50-[blank,

More information

Calibration Due Date Chroma Programmable AC Source 61604

Calibration Due Date Chroma Programmable AC Source 61604 Test #: L12132802 Date: 12/18/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L12132802 LW52-BRZ-110-00 Report Prepared For:

More information

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description: Project Number Date 17.01932 7/21/2017 Test Sample Description Catalog Number: Description: P90812827K9 Med Step Design Track Lighting Lab 1 Sphere Photometry Test Method: Preburn Time: Time To Stabilize:

More information

LLIA A-R02*

LLIA A-R02* Report of Test LLIA000762-001A-R02* *This test report supersedes test report LLIA000762-001A-R01 Catalog Number: MLS3-I-HO-K40-4-X-WSOP-X-XXX-X One Osram Optotronic OTi 30/0-277/1A0 DIM L LED driver. 0.0Vac,

More information

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description: Project Number Date 17.01926 7/17/2017 Test Sample Description Catalog Number: Description: P90310927K9 Med Flex Head, Single Arm Gimbal Design Track Lighting Lab 1 Sphere Photometry Test Method: Preburn

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions. Report No: L031610901 Date: 4/7/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L031610901 Report Prepared For: Osram Sylvania, Inc. Model

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB02540 PAGE: 1 OF 7 CATALOG NUMBER: VAN1LED12NW (SURFACE MOUNT - DROP LENS) LUMINAIRE: WHITE ALUMINUM SHEET METAL HOUSING, ONE WHITE CIRCUIT BOARD WITH 48 LEDS, FROSTED POLYCARBONATE DROP

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000676-003A Catalog Number: ML3WL-I/D-MO/MO-K40-4-X-LOH/LOH-X-X-UNV Two Osram Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous Efficacy Performance

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000676-010A Catalog Number: ML5WL-I/D-HO/HO-K40-4-X-LOH/LOH-X-X-UNV Optotronic OTi 30/120-277/1A0 DIM L LED drivers. Total Light Output Luminaire Power Luminous Efficacy Performance

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L08133001 Date: 8/22/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L08133001 LUX-LED-360-4R-UNV-U Report Prepared

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L111506001 Date: 11/25/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L111506001 Report Prepared For: Osram Sylvania 200 Ballardvale

More information

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India

IES LM MEASUREMENT AND TEST REPORT For. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida UP India IES LM-79-08 MEASUREMENT AND TEST REPORT For Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase 2 Extn. Noida 201305 UP India Test Model: L14EH80-W/HB/50K Report Type: Electrical and Photometric

More information

Report of Test LLIA A

Report of Test LLIA A Report of Test LLIA000930-008A Catalog Number: AR300-I/D-HO/HO-K40-80--4-XX-WSCL/LOH-XXXX-120 One Osram Optotronic OTi 85/120-277/2A0 DIMLT2 L LED driver 120.0Vac, 60.00Hz, 0.4998A, 59.53W, 0.993PF, 3.5%THD(i)

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED11WA19/300/827K-GU24-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description: Project Number Date 15.00487 3/26/2015 LAB 6 Test Sample Description Catalog Number: Description: P3408-0930K9 Close to Ceiling fixture Test Method: Preburn Time: Time To Stabilize: Total Operating Time:

More information

Lighting Sciences

Lighting Sciences Lighting Sciences www.lightingsciences.com Lighting Sciences Inc. 7826 E. Evans Road Scottsdale, Arizona 85260 USA Tel: 480-991-9260 Fax: 480-991-0375 INTENSITY(CANDLEPOWER) SUMMARY OUTPUT LUMENS ANGLE

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED15WA21/300/830K-GU24-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS 66227 IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W. 84th St., Shawnee, KS 66227 Test Model: LED11WA19/300/840K-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous

More information

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, ,

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, , Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-2002 UL1598-2008/ UL1993-2012 Prepared For Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, +91

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L121500401 Date: 12/8/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L121500401 Report Prepared For: Bartco Lighting 5761 Research

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB02175 PAGE: 1 OF 7 CATALOG NUMBER: SK16XL20RYY LUMINAIRE: STAMPED STEEL CEILING PAN WITH WHITE FINISH, 10 LED BOARDS EACH WITH 8 LEDS, ACRYLIC DROP LENS WITH SMOOTH FINISH. LAMPS: EIGHTY

More information

Soraa Internal Report: IES LM79 08

Soraa Internal Report: IES LM79 08 PRELIMINARY Soraa Internal Report: IES LM79 08 Test results reported for: Part Number: SM16-09-36D-930-03 Soraa MR16, GU5.3/12V, 3000K, 95CRI, 9W, 36degree Relevant Standards IES LM-79 ANSI C78.377 IES

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Revolution Lighting Technologies, Inc 2280 Ward Ave. Simi Valley, CA. 93065 Roman Sukharev, (877)

More information

Soraa Internal Report: IES LM79-08

Soraa Internal Report: IES LM79-08 PRELIMINARY Soraa Internal Report: IES LM79-08 Test results reported for: Customer Reference P/N: SR111-18-08D-830-03 Manufacturing P/N: SR111-18-08D-830-03 Soraa AR111, G53/12V, 3000K, 80CRI, 18.5W, 8degree

More information

Report of Test LLIA A

Report of Test LLIA A eport of Test LLIA000930-009A Catalog Number: A300-I/D-MO/MO-K40-80--4-XX-LOH/LOH-XXXX-120 One Osram Optotronic OT50W/PG1400C/UNV/DIM/L LED driver 120.0Vac, 60.00Hz, 0.3027A, 36.14W, 0.995PF, 7.7%THD(i)

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L10138201 Date: 10/28/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L10138201 LUX-LED-360-4R-UNV-URDL Report Prepared

More information

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA LM-79-08 Test Report For Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA. 93065 Outdoor Pole/Arm-Mounted Area and Roadway Luminaires Model name(s): 1130SG-35T Remark:

More information

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description: Project Number Date 17.00221 1/24/2017 LAB 6 Test Sample Description Catalog Number: Description: P350055-00930 1-Lt. DCLED Flush Mount Test Method: Preburn Time: Time To Stabilize: Total Operating Time:

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Maxlite Jersey Blvd Rancho Cucamonga, CA 91730

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Maxlite Jersey Blvd Rancho Cucamonga, CA 91730 Test #: L04144501 Date: 4/15/2014 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L04144501 MLFP22EP3641 Report Prepared For: Maxlite

More information

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063 Report No: L091706907 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Report No: L091706907 Issue Date: 10/16/2017 Report Prepared For: USTE, dba Vista Professional Outdoor Lighting 1625

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Report No: L091502901 Date: 9/15/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L091502901 Report Prepared For: Maxlite Model Number: WP-OPX120UT3-50BZZ

More information

Calibration Due Date Chroma Programmable AC Source 61604

Calibration Due Date Chroma Programmable AC Source 61604 Test #: L12131802 Date: 12/17/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L12131802 FL/T8-32W/17W IU 350 Report Prepared

More information

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux Report of Test LLIA000965 006 Integrating Sphere Report Performance Summary Voltage Current Power Frequency Power Factor Current THD Total Luminous Flux Efficacy Chromaticity (x,y) (u',v') Duv CCT CRI

More information

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were)

More information

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were)

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Test #: L12133401 Date: 12/18/2013 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927 0 Test Report: Model Number: L12133401 FL/T8-32W/22W AC 410 Report Prepared

More information

INDEPENDENT TEST LABORATORY REPORT No A

INDEPENDENT TEST LABORATORY REPORT No A Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were)

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Photometric and Optical Testing Services Cheltenham Film and Photographic Studios Hatherley Lane Cheltenham Gloucestershire GL51 6PN UK Tel: 01242 701300 Page 2 of 14 Photometric

More information

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux

Performance Summary Voltage Current Power Frequency Power Factor Current THD A W Total Luminous Flux Report of Test LLIA000901 008B Integrating Sphere Report Performance Summary Voltage Current Power Frequency Power Factor Current THD Total Luminous Flux Efficacy Chromaticity (x,y) (u',v') Duv CCT CRI

More information

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH Report No: L101605127 Date: 12/8/2016 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com NVLAP LAB CODE 200927-0 Report No: Prepared For: Model Number: Test: L101605127 Number Eight Lighting

More information

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MaxLite 12 York Ave. West Caldwell, NJ.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MaxLite 12 York Ave. West Caldwell, NJ. Test #: L11125507 Date: 12/5/2012 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Report: Model Number: L11125507 MLVT22D4535 Report Prepared For: MaxLite

More information

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE: INDEPENDENT LABORATORIES, INC. REPORT NUMBER: ITL88648-GONIOPHOTOMETRY PAGE: 1 OF 7 CATALOG NUMBER: RP-LUM-48-3500-WHT LUMINAIRE: FABRICATED WHITE PAINTED METAL TOP HOUSING/REFLECTOR, 12 WHITE CIRCUIT

More information