COMPACT Series type HCFB / HCFT (Plastic impellers)

Size: px
Start display at page:

Download "COMPACT Series type HCFB / HCFT (Plastic impellers)"

Transcription

1 Plate mounted axial flow fans COMPACT HCFB/HCFT PLATE MOUNTED AXIAL FLOW FANS COMPACT Series type HCFB / HCFT (Plastic impellers) Compact design Corrosion resistance Flame retardant terminal box Range of low profile plate mounted axial fans fitted with plastic impellers (250 to 630) or aluminium hub and plastic blades (710 to 1000). Available, depending upon the model, with single or three phase motors in 2, 4, 6 or 8 poles. Motors All the motors are IP65 (1), Class F insulation (2), equipped with thermal protection. All motors are speed controllable except 2 pole and /4-630, /4-710, 800, 900, 1000 models. Electrical supplies: Single phase 230V-50Hz. (Capacitor located inside the wiring terminal box). Three phase 230/400V-50Hz or 400V-50Hz. (See characteristic chart). (1) 2 pole motor and 800, 900 & 1000 models are IP55. (2) Working temperatures from -40ºC up to 70ºC. Except models 800 to 1000 suitable for usage in environments up to +40ºC. Additional Information Standard air direction: form (A) configuration (Motor over Impeller). On request: Air direction: form (B) configuration (Impeller over Motor). Three phase motors suitable for inverter control (E22 version). Inlet finger proof guard for models 800 to A P P L I C A T I O N S Compact design created by the combination of the motor with the factory matched direct drive wrap around impeller hub Impeller dynamically balanced Mounting plate, motor support and finger proof guard protected by cataforesis primer and black polyester paint finish. Stainless steel screws Configuration for models Ø 800 to 1000 Wiring terminal box in flame retardant plastic V0. Cable gland PG-11 Warehouses Workshops Commercial premises Car parks 56 Impeller dynamically balanced: Impellers are dynamically balanced, according to ISO 1940 standard, giving vibration free operation Agricultural extract or supply applications inting Installations Greenhouses Conditioning groups Air conditioning

2 PLATE MOUNTED AXIAL FLOW FANS COMPACT Series type HCBB / HCBT (Aluminium impellers) Compact design Corrosion resistance Flame retardant terminal Box Range of low profile plate mounted axial fans fitted with aluminium impellers. Available, depending upon the model, with single or three phase motors in 2, 4, 6 or 8 poles. Motors All the motors are IP65 (1), Class F insulation (2), equipped with thermal protection. All motors are speed controllable except 2/315/H, 2/355/H and /4-630, /4-710, 800, 900, 1000 models. Electrical supplies: Single phase 230V-50Hz. (Capacitor located inside the wiring terminal box) Three phase 230/400V-50Hz or 400V-50Hz (See characteristic chart.) (1) 2/315/H,2/355/H and 800, 900 & 1000 models are IP55. (2) Working temperatures from -40ºC up to 70ºC (except /2-315/H,/2-355/H, 800, 900 and 1000 models: suitable for usage in environments up to +40ºC). Additional Information Standard air direction: form (A) configuration (Motor over Impeller). ON REQUEST: Air direction: form (B) configuration (Impeller over Motor). Three phase motors suitable for inverter control (E22 version). Inlet finger proof guard for models 800 to Plate mounted axial flow fans COMPACT HCBB/HCBT Explosion proof versions in accordance to ATEX Directive for three phase models: - Increase safety Ex II2G EExe IIT3 (except 2 pole motors). - Flame proof only for models 800 to 1000, Ex II2G EExd IIBT5 or EExd IICT4. Working temperatures up to 40ºC A P P L I C A T I O N S Compact design created by the combination of the motor with the factory matched direct drive wrap around impeller hub. Impeller dynamically balanced Mounting plate, motor support and finger proof guard protected by cataforesis primer and black polyester paint finish. Stainless steel screws Configuration for models Ø 800 to 1000 Wiring terminal box in flame retardant plastic V0. Cable gland PG-11 Warehouses Workshops Commercial premises Car parks Impellers are dynamically balanced, according to ISO 1940 standard, giving vibration free operation Agricultural extract or supply applications Greenhouses inting Installations Conditioning groups Air conditioning 57

3 Plate mounted axial flow fans COMPACT HCFB/HCFT - HCBB/HCBT Reference H C F T / / H H: Compact Plate Axial Fan 5 - Number of poles: 2 - C: Series designation 3 2: (approx r.p.m Hz) 3 - Impeller Type: 4: (approx r.p.m Hz) F: Ø 250-Ø 630 Fixed blade plastic 6: (approx. 900 r.p.m Hz) impeller 8: (approx. 700 r.p.m Hz) Ø Ø 1000 Aluminium impeller 6 - : Nominal Diameter of impeller. (mm) hub and adjustable plastic blade impellers 7 - : Pitch Angle G: Adjustable plastic blade impellers H: high B: Ø 250-Ø 400 Fixed blade aluminium impeller L: low Ø Ø 1000 Adjustable blade aluminium impeller 4 - Electrical supply: 3 -B: Single phase 3 -T: Three phase Supply Voltages and Frequencies A 8 - Direction of Air: A: Motor over Impeller B: Impeller over Motor 9 - Special Construction X: Motor support without inlet finger guard Mains supply voltage SINGLE PHASE 220V 50Hz, 240V 50Hz THREE PHASE 220V 50Hz 240V 50Hz L: Weatherproof Protected C: Condensation drain holes on motor EX: Explosion proof versions in accordance to ATEX Directive, for three phase models: - EXE: Increased safety II2G EExeIIT3 - EXD: Flame proof, only for models 800 and 1000 II2G EExdIIBT5 or EExdIICT4 G: Special corrosion treatment for agricultural applications TF: With anticorrosive Teflon paint finish Motor type Connection Speed 230V 50Hz 230/400V 50Hz See wiring diagram High High Low* THREE PHASE 230/400V 50Hz High 380V 50Hz High 415V 50Hz 400V 50Hz Low* * From sizes 450 up to 630 mm diameter. Acoustic characteristics The sound levels NPS- shown in the technical characteristic chart, correspond to the value of sound pressure db(a), measured in free field conditions at a distance equivalent to three times the diameter of the impeller with a minimum of 1.5 meters. Sound power level spectrum in db(a) at the corresponding frequency band in Hz. LwA ASP QMAX LwA ASP QMAX /L /H /L /H /L /H LwA ASP QMAX /L /H /L /H /L /H LwA ASP QMAX /L /H /L /H /L /H

4 Technical characteristics with PLASTIC impellers (HCGB, HCFB, HCGT & HCFT) Before making any electrical connection ensure that the voltage and frequency of the mains electrical supply matches that of the fan data plate label. Model Speed Maximum Maximum current Sound Maximum Weight Speed* power (A) pressure air controller absorbed level volume (r.p.m.) (W) at 230 V at 400 V (db(a)) (m 3 /h) (kg) SINGLE PHASE 2 POLES HCFB/2-250/H , HCGB/2-315/L , HCGB/2-355/J , SINGLE PHASE 4 POLES HCFB/4-250/H , REB-1 HCFB/4-315/H , REB-1 HCFB/4-355/H , REB-2,5 HCFB/4-400/H , REB-2,5 HCFB/4-450/H , REB-2,5 HCFB/4-500/H , REB-5 HCFB/4-560/H , REB-5 HCFB/4-630/H , SINGLE PHASE 6 POLES HCFB/6-355/H , REB-1 HCFB/6-400/H , REB-1 HCFB/6-450/H , REB-2,5 HCFB/6-500/H , REB-2,5 HCFB/6-560/H , REB-2,5 HCFB/6-630/H , REB-5 HCFB/6-710/H , SINGLE PHASE 8 POLES HCFB/8-450/H , REB-1 HCFB/8-500/H , REB-1 HCFB/8-560/H , REB-2,5 HCFB/8-630/H , REB-2,5 HCFB/8-710/H , THREE PHASE 2 POLES HCFT/2-250/H ,9 0, HCGT/2-315/G ,4 0, HCGT/2-355/I ,6 0, THREE PHASE 4 POLES HCFT/4-250/H ,3 0, RMT-1,5 HCFT/4-315/H ,6 0, RMT-1,5 HCFT/4-355/H ,8 0, RMT-1,5 HCFT/4-400/H ,4 0, RMT-1,5 HCFT/4-450/H ,7 1, RMT-1,5 HCFT/4-500/H ,7 1, RMT-3,5 HCFT/4-560/H ,9 2, RMT-3,5 HCFT/4-630/H ,2 3, HCFT/4-710/H ,0 4, HCFT/4-800/L-X (1,5 kw) ,6 3, HCFT/4-800/H-X (3 kw) ,6 7, HCFT/4-900/L-X (3 kw) ,3 6, HCFT/4-900/H-X (5,5 kw) , HCFT/4-1000/L-X (3 kw) ,3 7, HCFT/4-1000/H-X (5,5 kw) , * Three phase speed controllers (RMT) are suitable for 400V. Plate mounted axial flow fans COMPACT HCFB/HCFT - HCBB/HCBT 59

5 Plate mounted axial flow fans COMPACT HCFB/HCFT - HCBB/HCBT Technical characteristics with PLASTIC impellers Model Speed Maximum Maximum current Sound Maximum Weight Speed* power (A) pressure air controller absorbed level volume (r.p.m.) (W) at 230 V at 400 V (db(a)) (m 3 /h) (kg) THREE PHASE 6 POLES HCFT/6-355/H ,5 0, RMT-1,5 HCFT/6-400/H ,5 0, RMT-1,5 HCFT/6-450/H ,8 0, RMT-1,5 HCFT/6-500/H ,9 0, RMT-1,5 HCFT/6-560/H ,6 0, RMT-1,5 HCFT/6-630/H ,0 1, RMT-1,5 HCFT/6-710/H ,9 3, HCFT/6-800/L-X (0,55 kw) ,9 2, HCFT/6-800/H-X (0,75 kw) ,3 2, HCFT/6-900/L-X (1,1 kw) ,7 3, HCFT/6-900/H-X (1,5 kw) , HCFT/6-1000/L-X (1,1 kw) ,6 3, HCFT/6-1000/H-X (1,5 kw) ,6 4, THREE PHASE 8 POLES HCFT/8-450/H ,7 0, RMT-1,5 HCFT/8-500/H ,7 0, RMT-1,5 HCFT/8-560/H ,0 0, RMT-1,5 HCFT/8-630/H ,3 0, RMT-1,5 HCFT/8-710/H ,0 1, HCFT/8-800/L-X (0,25 kw) ,2 1, HCFT/8-800/H-X (0,37 kw) ,0 1, HCFT/8-900/L-X (0,37 kw) ,8 1, HCFT/8-900/H-X (0,75 kw) ,5 2, HCFT/8-1000/L-X (0,37 kw) ,0 1, HCFT/8-1000/H-X (0,75 kw) ,6 2, *Three phase speed controllers (RMT) are suitable for 400V. 60

6 Explosion proof types only work at an environmental temperature between -30ºC and +40ºC. Technical characteristics with ALUMINIUM impellers (HCBB, HCBT) Model Speed Maximum Maximum current Sound Maximum Weight Speed* power (A) pressure air controller absorbed level volume (r.p.m.) (W) at 230 V at 400 V (db(a)) (m 3 /h) (kg) HCBB/2-250/H SINGLE PHASE 2 POLES 1, HCBB/2-315/H , HCBB/2-315/L , HCBB/2-355/H , HCBB/2-355/J , HCBB/4-250/H SINGLE PHASE 4 POLES 0, REB-1 HCBB/4-315/H , REB-1 HCBB/4-355/H , REB-2,5 HCBB/4-400/H , REB-2,5 HCBB/4-450/H , REB-2,5 HCBB/4-500/H , REB-5 HCBB/4-560/H , REB-5 HCBB/4-630/H , HCBB/6-355/H SINGLE PHASE 6 POLES 0, REB-1 HCBB/6-400/H , REB-1 HCBB/6-450/H , REB-2,5 HCBB/6-500/H , REB-2,5 HCBB/6-560/H , REB-2,5 HCBB/6-630/H , REB-5 HCBB/6-710/H , HCBB/8-450/H SINGLE PHASE 8 POLES 0, REB-1 HCBB/8-500/H , REB-1 HCBB/8-560/H , REB-2,5 HCBB/8-630/H , REB-2,5 HCBB/8-710/H , THREE PHASE 2 POLES HCBT/2-250/H ,9 0, HCBT/2-315/H ,1 1, HCBT/2-315/G ,4 0, HCBT/2-355/H ,3 1, HCBT/2-355/I ,6 0, THREE PHASE 4 POLES HCBT/4-250/H ,3 0, RMT-1,5 HCBT/4-315/H ,6 0, RMT-1,5 HCBT/4-355/H ,8 0, RMT-1,5 HCBT/4-400/H ,4 0, RMT-1,5 HCBT/4-450/H ,7 1, RMT-1,5 HCBT/4-500/H ,7 1, RMT-3,5 HCBT/4-560/H ,9 2, RMT-3,5 HCBT/4-630/H ,2 3, HCBT/4-710/H ,0 4, HCBT/4-800/L-X (1,5 kw) ,6 3, HCBT/4-800/H-X (3 kw) ,6 7, HCBT/4-900/L-X (3 kw) ,3 6, HCBT/4-900/H-X (5,5 kw) , HCBT/4-1000/L-X (3 kw) ,3 7, HCBT/4-1000/H-X (5,5 kw) , *Three phase speed controllers (RMT) are suitable for 400V. Plate mounted axial flow fans COMPACT HCFB/HCFT - HCBB/HCBT 61

7 Plate mounted axial flow fans COMPACT HCFB/HCFT - HCBB/HCBT Technical characteristics with ALUMINIUM impellers Model Speed Maximum Maximum current Sound Maximum Weight Speed* power (A) pressure air controller absorbed level volume (r.p.m.) (W) at 230 V at 400 V (db(a)) (m 3 /h) (kg) THREE PHASE 6 POLES HCBT/6-355/H ,5 0, RMT-1,5 HCBT/6-400/H ,5 0, RMT-1,5 HCBT/6-450/H ,8 0, RMT-1,5 HCBT/6-500/H ,9 0, RMT-1,5 HCBT/6-560/H ,6 0, RMT-1,5 HCBT/6-630/H ,0 1, RMT-1,5 HCBT/6-710/H ,9 3, HCBT/6-800/L-X (0,55 kw) ,9 2, HCBT/6-800/H-X (0,75 kw) ,3 2, HCBT/6-900/L-X (1,1 kw) ,7 3, HCBT/6-900/H-X (1,5 kw) , HCBT/6-1000/L-X (1,1 kw) ,6 3, HCBT/6-1000/H-X (1,5 kw) ,6 4, THREE PHASE 8 POLES HCBT/8-450/H ,7 0, RMT-1,5 HCBT/8-500/H ,7 0, RMT-1,5 HCBT/8-560/H ,0 0, RMT-1,5 HCBT/8-630/H ,3 0, RMT-1,5 HCBT/8-710/H ,0 1, HCBT/8-800/L-X (0,25 kw) ,2 1, HCBT/8-800/H-X (0,37 kw) ,0 1, HCBT/8-900/L-X (0,37 kw) ,8 1, HCBT/8-900/H-X (0,75 kw) ,5 2, HCBT/8-1000/L-X (0,37 kw) ,0 1, HCBT/8-1000/H-X (0,75 kw) ,6 2, *Three phase speed controllers (RMT) are suitable for 400V. 62

8 Dimensions (mm) Models HCBT-B/2-315/H HCBT-B/2-355/H F J M ø ø Number of Poles ø Number of Poles Tri- Single- Model A B C D E /2 /4 /6 /8 G /2 /4 /6 /8 K L phase phase ,5 40, ,5 44,5 44, , , , , , ,5 218,5 218, ,5 16, A C B ØE Ø G Ø D J K L F H Ø N Plate mounted axial flow fans COMPACT HCFB/HCFT - HCBB/HCBT Model A B C Ø D Ø E F Ø G H J K L Ø N HCBT-B/2-315/H ,5 77, HCBT-B/2-355/H C Ø F ø ø /4 /6 /8 /4 /6 /8 Model A B D J G L H L H L H L H L H L H

9 Plate mounted axial flow fans COMPACT HCFB/HCFT - HCBB/HCBT Installation accessories DEF-D PER-CN PER-W Wire Protection Guards DEF-AN (for models 800 and 1000) PER-CN PER-W Exhaust Side Louvre Shutters Model Outlet Inlet Plastic Aluminium HCFB / HCFT 250 DEF-250 D PER-250 W PER-250 CN HCFB / HCFT 315 DEF-325 D PER-355 W PER-355 CN HCFB / HCFT 355 DEF-375 D PER-355 W PER-355 CN HCFB / HCFT 400 DEF-450 D PER-400 W PER-400 CN HCFB / HCFT 450 DEF-450 D PER-450 W PER-450 CN HCFB / HCFT 500 DEF-525 D PER-500 W PER-500 CN HCFB / HCFT 560 DEF-630 D PER-560 W PER-630 CN HCFB / HCFT 630 DEF-630 D PER-630 W PER-630 CN DEF-D DEF-1001A HCFT/4-1000/H HCFB / HCFT 710 DEF-800 D PER-710 W PER-710 CN HCFT 800 DEF-800 D DEF- 800 AN PER-800 W PER-800 CN HCFT 900 DEF-1000 D DEF- 900 AN PER-1000 W PER-1000 CN HCFT 1000 DEF-1000 D DEF-1000 AN PER-1000 W PER-1000 CN HCFT / / H DEF-1000 D DEF-1001 AN PER-1000 W PER-1000 CN Electrical accessories REB-1N / REB-2,5N Single phase electronic speed controllers REB-5 Single phase electronic speed controllers RMB/RMT Single and three phase auto transformer speed controllers REB-4 Auto REB-5 Auto Electronic single phase speed controllers with temperature sensor. For agricultural applications 64

10 rformance curves Series HCFB/HCFT HCBB/HCBT TCFB/TCFT Q = Air volume in, m 3 /hr and m 3 /s. = Static pressure in mmwg and. Dry air at 20ºC and 760 mmhg. Air flow data in accordance with the following standards: UNE , BS 848, rt 1; AMCA and ASHRAE Typical fan selection: Do not select the working point in the coloured area. To find the working point it is first necessary to plot the system resistance curve. The working point lies at the intersection between that curve and the fan performance curve. Example: Required air volume m 3 /h at 3 mmwg. Fan working point m 3 /h at 4 mmwg. mm WG Do Not Select a Fan with a Working Point in this Area Working Point of Fan Required Air Volume mmwg 2 pole System Resistance Curve Plate mounted axial flow fans COMPACT HCFB/HCFT - HCBB/HCBT mmwg 4 pole mmwg 4 pole

11 rformance curves Series HCFB/HCFT HCBB/HCBT TCFB/TCFT Plate mounted axial flow fans COMPACT HCFB/HCFT Q = Air volume in, m 3 /hr and m 3 /s. = Static pressure in mmwg and. Dry air at 20ºC and 760 mmhg. Air flow data in accordance with the following standards: UNE , BS 848, rt 1; AMCA and ASHRAE mmwg 4 pole mmwg 6 pole mmwg 4 pole mmwg 6 pole mmwg 6 pole mmwg 8 pole

12 rformance curves Series HCFB/HCFT HCBB/HCBT TCFB/TCFT Q = Air volume in, m 3 /hr and m 3 /s. = Static pressure in mmwg and. Dry air at 20ºC and 760 mmhg. Air flow data in accordance with the following standards: UNE , BS 848, rt 1; AMCA and ASHRAE mmwg 8 pole mmwg 8 pole Plate mounted axial flow fans COMPACT HCFB/HCFT 67

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with

More information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

supplied in Form (B) configuration. Airflow over Impeller- Motor. CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB-TCBT (Aluminium impellers) and TCFB-TCFT (Plastic impellers) NEW VERSIONS Description The S&P Cylindrical Cased Axial Fans feature, as the name suggests,

More information

Short casing. Long casing (L version) Commercial premises

Short casing. Long casing (L version) Commercial premises CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled

More information

Plate mounted axial flow fans HXBR / HXTR Series

Plate mounted axial flow fans HXBR / HXTR Series Plate mounted axial flow fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller, low sound level, protected against corrosion by cataforesis primer and a polyester

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced CENTRIFUGAL SINGLE INLET FANS CMB / CMT Series 80 C CONTINUOUS operation Range of centrifugal single inlet fans suitable for continuous extraction of airstreams temperature up to 80ºC (Series 1) or 150ºC

More information

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard, RADIAL CENTRIFUGAL FANS CBT-N Series CONTINUO Range of single inlet direct driven centrifugal fans designed for the continuous extraction of air stream up to 120ºC(1). The casings are manufactured from

More information

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers. ACOUSTIC CABINET FANS Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic

More information

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box ACOUSTIC CABINET FANS CENTRIBOX CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All

More information

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protected against corrosion by cataforesis primer and black polyester

More information

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB Applications The CMT-CMB range of fans are suitable for many general and OEM ventilation applications where the extract of nonhazardous heated air is required. The

More information

TGT Series Adjustable Pitch Fans

TGT Series Adjustable Pitch Fans CYLINDRICAL CASED AXIAL FLOW FANS Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot dipped

More information

TGT Series Adjustable Pitch Fans

TGT Series Adjustable Pitch Fans CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Range of adjustable pitch aerofoil blade, cased axial flow fans.casings formed from rolled sheet steel with a corrosion resistant hot

More information

ACOUSTIC CABINET FANS CVAB / CVAT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models

More information

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Additional Information Standard air direction: form (B) configuration (Impeller over ). models description: incorporated an "L" after blade pitch angle. E.g.

More information

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling MIXVENT-TH ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured from high strength

More information

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air

More information

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT BACKWARD CURVED CENTRIFUGAL FANS Series The CHVB-CHVT range is suitable for many general ventilation applications where high system resistances are present; i.e. systems with filters, dampers etc. Range

More information

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling ROOF MOUNTED FNS Series Mixed Flow Fans P P L I T I O N S Workshops ommercial premises Offices Restaurants and cafes Wine cellars asements Range of roof mounted mixed flow fans supplied as standard for

More information

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot CENTRIFUGAL IN-LINE FANS Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a pre-wired wiring junction

More information

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts LOW PRESSURE CENTRIFUGAL FANS Series Range of double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel. All the models are fitted with forward curved centrifugal

More information

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced. LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a

More information

CHMT Series, F Rated Fans

CHMT Series, F Rated Fans CNTRIFUGAL SINGL INLT FANS CT Series, F400 120 Rated Fans Officially approved to N12101-3 standard (certificate number 0370-CPD-0348) Range of single inlet direct drive centrifugal fans designed for smoke

More information

CENTRIFUGAL IN-LINE FANS VENT Series

CENTRIFUGAL IN-LINE FANS VENT Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a prewired wiring junction box and a robust mounting foot.

More information

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to

More information

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVB / CVT Series Cabinet fans manufactured from heavy gauge galvanised steel sheet and internally lined with melamine foam flame retardant acoustic insulation (M1). All models incorporate double inlet single phase direct-drive

More information

BELT DRIVEN CABINET FANS CVTT Series

BELT DRIVEN CABINET FANS CVTT Series Range of forward curved belt drive cabinet fans manufactured from galvanised steel sheet, internally lined with melamine thermo-acoustic insulation. ll models incorporate a double inlet low pressure centrifugal

More information

MIXVENT-TH Series Mixed Flow Fans

MIXVENT-TH Series Mixed Flow Fans ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans 0 021682 603075 P P L I T I O N S Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured

More information

DIRECT-AIR ILB / ILT Series Rectangular duct fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller

More information

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones. CJTHT Axial fans 400ºC/2h and 300ºC/2h With soundproofed box Extraction units with axial fans to work inside fire danger zones. Fan: Sheet steel long casing fan. Galvanised sheet steel structure with thermal

More information

Centrifugal medium-pressure fans fitted with multi-blade

Centrifugal medium-pressure fans fitted with multi-blade CMP/ATEX CMP/ATEX impeller Centrifugal medium-pressure fans fitted with multi-blade with ATEX certification Centrifugal single-inlet, medium-pressure fans with casing and sheet steel impeller to work in

More information

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Multifunctional 400ºC/2h and 300ºC/2h roof fans HTMF Multifunctional 400ºC/2h and 300ºC/2h roof fans Multifunctional 400ºC/2h ceiling fans to work inside fire danger zones, designed for smoke extraction in industrial or similar buildings. 0370-CPR-0544

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans Hacer título más resumido ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans Construction Casing The fan casings are manufactured from heavy gauge galvanised sheet steel and

More information

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information. In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Dynamically-balanced impellers with extremely robust cores CMP T 5.5 Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.

More information

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows HTMH Multifunctional roof fans for large flows Multifunctional roof fans, highly robust construction, for large flows Fan: Painted galvanised sheet steel base plate Turnable impellers cast aluminium. Protection

More information

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from to models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from to models).

More information

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity 400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,

More information

HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification

HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification HCH/ATEX HCT/ATEX HCH/ATEX: Robust wall-mounted axial fans with ATEX certification HCT/ATEX: Robust long-cased axial fans with ATEX certification Circular axial fans (HCH) or Long-cased fans (HCT) with

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

CYLINDRICAL CASED AXIAL FLOW FANS

CYLINDRICAL CASED AXIAL FLOW FANS - Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate

More information

High-efficiency long-cased axial fans fitted industrial Brushless motor E.C. Fibreglass-reinforced plastic impeller.

High-efficiency long-cased axial fans fitted industrial Brushless motor E.C. Fibreglass-reinforced plastic impeller. HEPT/EW with High-efficiency long-cased axial fans fitted industrial Brushless motor E.C. BRUSHLESS MOTOR BRUSHLESS INDUSTRIAL E.C. Fibreglass-reinforced plastic impeller. Fan: Airflow direction from motor

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

CMP-L/EW B T D. Industrial Brushless Motors E.C. Motor power (CV) Three-phase VSD 400 V50/60 Hz. electrical power Maximum.

CMP-L/EW B T D. Industrial Brushless Motors E.C. Motor power (CV) Three-phase VSD 400 V50/60 Hz. electrical power Maximum. CMP-L/EW BRUSHLESS INDUSTRIAL BRUSHLESS MOTOR E.C. VARIABLE SPEED DRIVE VSD: Variable Speed Drive.. VSD1/B. VSD3/B Supply included with fan CONTROL Supply optional accesory SUPPLY VSD1/B: 220-240 V 50/60

More information

Fans for ATEX EXPLOSIVE ATMOSPHERES

Fans for ATEX EXPLOSIVE ATMOSPHERES Fans for ATEX EXPLOSIVE ATMOSPHERES An ATEX area is a mixture of air and inflammable gas, the vapour of an inflammable liquid, a fog of combustible liquid or combustible powder, which, if they catch fire,

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet THT/ROOF ROOF-MOUNTED SMOKE EXTRACTOR FANS THT/ROOF 400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet Roof-mounted helical extractor fans with vertical air outlet, for

More information

Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor.

Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor. HCH HCH Extremely robust wall-mounted, axial or tubular fans Axial or tubular wall-mounted fans, PL version fitted with a plastic rotor and AL version with an aluminium rotor. Fan: Airflow direction from

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans IN-LINE MIXED FLOW DUCT FANS Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 160 to 800 models) or with metal casing steel finished in a tough epoxy-polyester

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller

Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller HCH HCT HCH HCT Order code Robust wall-mounted axial or long-cased fans Robust wall-mounted axial or long-cased fans, PL version supplied with plastic impeller and AL version supplied with aluminium impeller

More information

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications. EuroSeries (ESR) Cowl & base moulded from recyclable polymeric material All sizes resistant to UV light Sizes 250 to 1000 dia are protected to IP54 Optional backdraught shutters and bird guard (250-630mm)

More information

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS - ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation CJBD/AL CJBD/ALS CJBD/ALF CJBX/AL CJBX/ALS CJBX/ALF VENTILATION UNITS WITH ALUMINIUM PROFILES According EU Regulation CJBD/AL CJBD/ALS CJBD/ALF CJBD/AL: Soundproofed ventilation units with profiles in

More information

CMR/EW EFFICIENT WORK

CMR/EW EFFICIENT WORK CMR/EW AC VARIABLE SPEED DRIVE VSD: Variable Speed Drive.. VSD1/A-RFM. VSD3/A-RFT Supply on request CONTROL Supply optional accesory SUPPLY VSD1/A-RFM: 220-240 V 50/60 Hz VSD3/A-RFT: 380-415 V 50/60 Hz

More information

CMP/EW EFFICIENT WORK

CMP/EW EFFICIENT WORK CMP/EW High-efficiency centrifugal single-inlet, medium-pressure fans with a direct motor and impeller with forward-facing blades fitted with IE3 asynchronous motor adjustable electronically. AC HIGHLY

More information

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

Max. airflow m 3 /s Diam. min. Diam. max

Max. airflow m 3 /s Diam. min. Diam. max Axial Fans Max. airflow m 3 /s Diam. min Diam. max 1% adjustable motor Assembly, any position Reversible (3% Reduction) Page Number AW AR AW.97 2 3 * * 13 AR.97 2 3 * * 134 ZSP 2.9 315 5 * * 13 ZAP 13.89

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Sabre Sickle Fan Assisted Roof Cowls (VSR) Sabre Sickle Fan Assisted Roof Cowls (VSR) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance Fully assembled cowl, separate plate axial fan Optional backdraught

More information

AXIAL FLOW CABINET FAN CGT Series

AXIAL FLOW CABINET FAN CGT Series Range of adjustable pitch aerofoil blade, axial flow cabinet fans. Fan casing manufactured from heavy gauge galvanised sheet steel internally lined with 25 mm thickness fireproof fibreglass acoustic insulation

More information

TD-ECOWATT AND DECOR-ECOWATT Series

TD-ECOWATT AND DECOR-ECOWATT Series S&P presents its new ranges of domestic and commercial fans with DC motors TD-ECOWATT AND DECOR-ECOWATT Series Up to 55% savings in energy consumption Reduced CO 2 emissions Improvement of the environment

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

Medium Pressure Centrifugal Fans

Medium Pressure Centrifugal Fans Medium Pressure Centrifugal Fans 2012 Edition ...About Axair Fans UK Application Knowledge: Over 20 years experience in general air movement; including corrosive, explosive and hot fume handling. Stock

More information

Square Mixed Flow Fans (MFQ)

Square Mixed Flow Fans (MFQ) Square Mixed Flow Fans (MFQ) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature +40 C Standard Thermal Overload Protection Sizes 400 to 500 3 phase are

More information

HIGH-POWERED VENTILATORS

HIGH-POWERED VENTILATORS HIGH-POWERED VENTILATORS WITH ROOF FANS 400ºC/2h The THT/HATCH series was designed using high-powered ventilator technology for smoke extraction in the event of a fire, and is equipped with THT series

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

BATHROOM EXTRACT FANS DECOR-100 Series

BATHROOM EXTRACT FANS DECOR-100 Series DECOR-1 Series Range of axial extractors with airflow rates of 1 m 3 /h, for connection to 1 mm diameter circular ducting. All the fans are manufactured from injection moulded plastic, fitted with neon

More information

CVHT Series - F rated cabinet fans

CVHT Series - F rated cabinet fans N 50-55 1/1/08 19:26 Página 50 BLT DRIVN BINT NS Series - 00 120 rated cabinet fans NW pproved to N12101- standard Range of belt drive cabinet fans designed for smoke extraction in fire conditions and

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans ROOF MOUNTD FANS MAX-TMP Series, entrifugal 400 º/2h Rated Fans Description - Applications The MAX-Temp range of roof extract fans are available in horizontal (TH-THT) or vertical (TV-TVT) discharge formats,

More information

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

Acoustic Twin Fans (ATQ)

Acoustic Twin Fans (ATQ) Acoustic Twin Fans (ATQ) Features and Benefits Available in sizes from 100 to 500mm dia 50mm Acoustically treated housing, Class O rated, self extinguishing, zero burn rate, resists ignition, no toxic

More information

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics CJBX CJBX/AL CJBX: Belt-driven acoustically-insulated ventilation units. CJBX/AL: Belt-driven ventilation units with aluminium profiles and prefinished sheet steel and acoustic insulation. CJBX Options

More information

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7 CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard

More information

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V)

Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V) Data sheet: Wilo-Drain TP 65 F 91/11 (1~230 V) Pump curves Wilo-Drain TP 65 F - 50 Hz - 2900 rpm Unit Max. delivery head H max 9.5 m Max. volume flow Q max 36 m 3 /h Optimal delivery head H opt 6.0 m Optimum

More information

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller. TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys

More information

HCH-HCT/EW EFFICIENT WORK. Wall-mounted or long-cased axial fans fitted with high-efficiency IE3 asynchronous motor adjustable electronically.

HCH-HCT/EW EFFICIENT WORK. Wall-mounted or long-cased axial fans fitted with high-efficiency IE3 asynchronous motor adjustable electronically. HCH-HCT/EW AC HIGHLY EFFICIENT IE3-COMPLIANT THREE-PHASE MOTORS AC VARIABLE SPEED DRIVE VSD: Variable Speed Drive.. VSD1/A-RFM. VSD3/A-RFT Supply on request CONTROL Supply optional accesory SUPPLY VSD1/A-RFM:

More information

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ Duct mounted fans axial flow Pacific HVAC Engineering 215 www.pacifichvac.com Tel. Australia 13 733 833 NZ 8 1 326 6 5 4 3 2 1 5 1 15 2 7 6 5 4 3 2 1 3 2.5 2 1.5 1.5 1 15.5 1 1.5 2 2.5 3 3.5 Volume m 3

More information

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and

More information

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series TD-SILENT ECOWATT - MODELS 5 to TD-SILENT ECOWATT - MODELS AND At 5% of full speed fan power consumption is reduced by 7% Low profile Mixed-flow fans with sound-absorbent insulation, extremely quiet, fan

More information

NEW Acoustic In-Line Fans (ACQ)

NEW Acoustic In-Line Fans (ACQ) NEW Acoustic In-Line Fans (ACQ) Acoustically treated housing, Class O rated, sandwich construction selected for maximum noise absorption Motors protected to IP44 Motor insulation Class B Maximum operating

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V)

Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V) Data sheet: Wilo-Drain TP 65 F 109/22 (3~400 V) Pump curves Wilo-Drain TP 65 F - 50 Hz - No. of poles: 2 Unit Max. delivery head H max 14.5 m Max. volume flow Q max 52.0 m 3 /h Optimal delivery head H

More information

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits Ultra quiet and low profile helicocentrifugal in-line fans suitable for a wide range of domestic and commercial applications. Fitted with sound absorbent insulation and manufactured with an adjustable

More information