Injects ionized air over an angle of 60 or 90. Straight Bar Nozzle

Size: px
Start display at page:

Download "Injects ionized air over an angle of 60 or 90. Straight Bar Nozzle"

Transcription

1 Ionizer (Air Push Type) KS Wide Range of Nozzles for Optimal Ionization From pin-point to wide-area ionization, the optimal ionization for the application is now possible. High-frequency AC method with excellent ion balance. Be sure to read Safety Precautions on page 8. Features Select the Nozzle for the Application Standard Nozzle Shower Nozzle Flat Nozzle An application example of the basic standard nozzle. Injects ionized air over an angle of 6 or 9. Injects ionized air over an angle of 9 to enable ionization of comparatively wide objects. Cleaning / 6 or 9 Combination of Standard Nozzle and Optional Tube Attach the Optional Tube to the Standard Nozzle to blow ionized air close to the workpiece for pin-point ionization. Straight Bar Nozzle Neutralizes static electricity over a wide area. Five ionization areas from to mm. Efficient Pin-point Ionization High-speed ionization of the target spot is possible by using a tube or metal pipe to get closer to the workpiece. The Ionizer can be brought as close as mm to the workpiece. High-frequency AC Method with Excellent Ion Balance ZJ-FA // ZJ-FA Uses more compact high-frequency AC method with excellent ion balance and stability. KS Approx.㧗kV V Approx.㧙kV 68kHz Combination of Flexible Tube Nozzle and Optional Cap Combine the nozzle cap at the tip of the nozzle to enable many ionization applications. 6 or 9 Only the -VDC power supply for the Ionizer is needed. No dangerous high-voltage wiring is required. Compact Type with Built-in Controller Controller section built in. Simple all-in-one Unit that installs easily just about anywhere. The Ionizer oscillates at a much higher frequency (68 khz) than the previous AC method to generate high-density ions. Noise generation is also reduced by a ±kv low-voltage corona discharge. Safe because the high voltage parts are covered by the nozzle. 8 With a flexible shower nozzle cap -VDC Power Supply with No High-voltage Wiring Required With standard nozzle Driven by -VDC power supply with no high-voltage wiring required. 9

2 KS Product Configuration Nozzles Ionizer Tubes For Standard Nozzle Caps For Flexible Tube Nozzle Shower Nozzle Cap Flat Nozzle Cap KS-ANDC-FT9 Standard Nozzle KS-ANNS Shower Nozzle Flat Nozzle KS-ANFT9 Straight Bar Nozzle Flexible Tube Nozzle KS-AAT Filter and Connector Air Clean Filter KS-AZ Stainless Steel Connector (See note.) KS-AZ Note: The Connector can be mounted to the Ionizer even with no Air Clean Filter. Ordering Information Ionizer KS-AAT Accessories Nozzles Product Standard Nozzle KS-ANNS Shower Nozzle 6 KS-ANSW6 9 KS-ANSW9 9 Flat Nozzle KS-ANFT9 Straight Bar Nozzle mm KS-ANSB mm KS-ANSB mm KS-ANSB mm KS-ANSB mm KS-ANSB Tubes Product -mm Conductive Urethane Tube KS-ANNS-U -mm Fluororesin Tube KS-ANNS-F -mm Silicone Tube KS-ANNS-S Caps Product 6 Flexible Shower Nozzle Cap KS-ANDC-SW6 9 Flexible Shower Nozzle Cap KS-ANDC-SW9 9 Flexible Flat Nozzle Cap KS-ANDC-FT9 Cleaning / mm KS-ANDC Optional Products Flexible Tube Nozzle mm KS-ANDC mm KS-ANDC mm KS-ANDC mm KS-ANDC Product Replacement Dischargers (set of ) Tool for Replacing Dischargers Stainless Steel Connector Air Clean Filter KS-AZT KS-AZ KS-AZ KS-AZ ZJ-FA // ZJ-FA KS 8

3 KS Ratings and Specifications Cleaning / Ionizer Item KS-AAT Power supply voltage VDC ±% Current consumption Discharge method Output voltage Safety circuit Discharge time Ion balance Fluid used Amount of generated ozone Supplied airflow Indicators Air pressure range Ambient temperature Ambient humidity Weight Approx. ma High-frequency AC (approx. 68 khz) ±kv Output alarms for ionization errors.8 s max. (at a distance of mm from air outlet) ±V or less (at a distance of mm from air outlet) Air (refer to Applicable Air). ppm or less (when standard nozzle used, at a distance of mm from air outlet and primary side voltage of. Mpa) Approx. L/min (ANR) (when standard nozzle used, at primary side voltage of. Mpa) Green POWER indicator lit while Ionizer ON, red ALM indicator lit for ionizing errors When Standard Nozzle or Flexible Tube Nozzle is used:. to. MPa When Standard Nozzle Tube is attached:. to. MPa When Shower Nozzle, Flat Nozzle, or Straight Bar Nozzle is used:. to. MPa to C (with no condensation or icing) % to 6% (with no condensation) Approx. g (Ionizer only) Accessories One ground lead ( m) Air Clean Filter ZJ-FA // ZJ-FA Item KS-AZ Fluid used Air Connection aperture R(Rc)/8 Collected particle size. µm Collection efficiency 99.9% Volume of air processed l/min (ANR) * Film area 9.9cm² Maximum voltage used.9 MPa Withstanding pressure. MPa Operating temperature range to C Weight g Recommended tightening torque to 6 N cm Unit material Aluminum alloy (alumite treated) Element material Porous, hollow thread membrane * At. MPa (pressure drop of. MPa) KS 8

4 Discharge Characteristics (Typical) KS Standard Nozzle 6 C Shower Nozzle 9 C Shower Nozzle KS-ANNS KS-ANSW6 KS-ANSW9.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure Flat Nozzle -mm Straight Bar Nozzle -mm Straight Bar Nozzle KS-ANFT9 KS-ANSB KS-ANSB.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure Cleaning / -mm Straight Bar Nozzle -mm Straight Bar Nozzle -mm Straight Bar Nozzle KS-ANSB KS-ANSB KS-ANSB.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure.MPa Pressure ZJ-FA // ZJ-FA KS 8

5 KS Flexible Tube Nozzle Standard Nozzle with Conductive Standard Nozzle with Fluororesin Urethane Tube Tube Connected to KS-ANNS Connected to KS-ANNS Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm.mpa Pressure Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm.mpa Pressure Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm.mpa Pressure Cleaning / Standard Nozzle with Silicon Tube Flexible Tube and 6 Shower Nozzle Flexible Tube and 9 Shower Cap Nozzle Tube KS-ANNS-S@ Connected to KS-ANNS KS-ANDC-SW6 Connected to KS-ANDC@ KS-ANDC-SW9 Connected to KS-ANDC@ Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm.mpa Pressure Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm.mpa Pressure Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm.mpa Pressure Flexible Tube and Flat Nozzle Cap KS-ANDC-FT9 Connected to KS-ANDC@ Tube length: mm Tube length: mm Tube length: mm Tube length: mm Tube length: mm.mpa Pressure ZJ-FA // ZJ-FA KS 86

6 Connection Diagrams KS Wiring Diagram Terminal Block Diagram Power supply VDC Ground -VDC input power supply Ground (power supply and output) Output terminal Alarm output LOAD ma max. VDC max. Note: Alarm outputs are NC. Safety Precautions Refer to Warranty and Limitations of Liability on page F-. WARNING Precautions for Correct Use This product is not designed or rated for Do not use the product in atmospheres or environments that ensuring safety of persons. Do not use it for exceed product ratings. such purpose. Dimensions Ionizer (Unit: mm) Cleaning / KS dia. 9 8 R dia. 6 dia. G /8 G /8 R /8 Plug R /8 Plug ZJ-FA // ZJ-FA KS 8

7 KS Nozzles and Optional Products Used with the Ionizer Nozzles Standard Nozzle KS-ANNS (M ). dia. (ion air outlet) 6 Shower Nozzle KS-ANSW6 (M ) Shower Nozzle KS-ANSW9 (M ) 6 6 dia. (See note.) (). dia. (Double walled) dia. () Seven, dia. (ion air outlet) (.) (Double walled) dia. 8 () Seven, dia. (ion air outlet) (.) (Double walled) Straight Bar Nozzles KS-ANSB@ Flat Nozzle KS-ANFT9 Cleaning / dia. (M ) (8.) Double-wall thickness: Double-wall thickness: (nut) 6 dia. (B) A Pitch N,. dia. (ion air outlet) C (L) 6 A B C L N KS-ANSB KS-ANSB KS-ANSB KS-ANSB KS-ANSB dia. (M ) dia. Double-wall thickness: (8.) Flexible Tube Nozzles KS-ANDC@ (M ) dia. 6 dia. Double-wall thickness: (nut) (.) (9.) 8 (9) dia. dia. (ion air outlet) Five, dia. (ion air outlet) (Double walled) (Double walled) dia. dia. dia. (L) A A L KS-ANDC 9 KS-ANDC 9 KS-ANDC 9 KS-ANDC 9 KS-ANDC 9 ZJ-FA // ZJ-FA KS 88

8 KS Caps Flexible Flat Nozzle Cap KS-ANDC-FT9 Flexible Shower Nozzle Caps Optional Tubes Optional Tubes for Standard Nozzles (9.) Lock nut.. (Double walled) (Double walled) Five, dia. (ion air outlet) A A dia. 6 6 (Double walled) Seven, dia. (ion air outlet) Type A KS-ANDC-SW6 6 KS-ANDC-SW9 9 A B C KS-ANNS-U 6 dia. dia. Conductive Urethane Tube KS-ANNS-F dia. dia. Fluororesin Tube KS-ANNS-S dia. dia. Silicon Tube Optional Products Optional Air Clean Filter KS-AZ Stainless Steel Connector KS-AZ 9 6. IN dia. dia. Rc/8 dia. R/8 R/8 (Double walled). (opposing) Attached to the Ionizer for air tube connection. If using products from other manufacturers, consider using stainless steel products for less impact on the ozone layer. Cleaning / ZJ-FA // ZJ-FA KS Cat. No. E86-E- In the interest of product improvement, specifications are subject to change without notice. 89

High-frequency AC Method. panasonic-electric-works.net/sunx. A new style of charge removal New ultra-compact, high-performance ionizer!

High-frequency AC Method. panasonic-electric-works.net/sunx. A new style of charge removal New ultra-compact, high-performance ionizer! 199 PHOTOEECTRIC PHOTOEECTRIC Ultra-compact SERIES Related Information High-frequency AC Method General terms and conditions... F-17 Glossary of terms... P.11 guide... P.175~ General precautions... P.15

More information

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil

How to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil Ionizer / with surface potential sensor Series IZS0 How to Order 00 0 00 00 Ionizer IZ S 0 0 Bar length Bar length 00 mm 0 mm mm 00 mm 00 mm Ionizer Made to Order Bar type Size Electrode needle material

More information

Static Electricity Removing Unit Ionizer Blow Type

Static Electricity Removing Unit Ionizer Blow Type Low particle generation type Catalog No.BK-R Static Electricity Removing Unit Ionizer Blow Type Series KOGANEI Brand All products are RoHS compliant. A wealth of variations Simple maintenance Standard

More information

Ionizer (Nozzle type) Series IZN10

Ionizer (Nozzle type) Series IZN10 262 Series IZN0 / Nozzle type (Nozzle type) Series IZN0 RoHS Slim and compact: 6mm thickness. Nozzle selectable: Energy saving, large flow types and female threads for piping. ±0V ion balance: High frequency

More information

Blow Type Application Examples

Blow Type Application Examples Blow Type pplication Examples Removal of static charges when taking out or storing wafers voids electrostatic discharging when taking wafers out of their cassettes, and prevents the stored wafers from

More information

High-frequency AC Method. panasonic-electric-works.net/sunx

High-frequency AC Method. panasonic-electric-works.net/sunx 1091 PHOTO PHOTO Thin Type Ionizer High-frequency AC Method General terms and conditions... F-17 Related Information Glossary of terms... P.1401 guide... P.1075~ General precautions... P.1405 Conforming

More information

ER-VSERIES. A new style of charge removal. New ultra-compact, high-performance ionizer! ULTRA-COMPACT IONIZER High-frequency AC Method

ER-VSERIES. A new style of charge removal. New ultra-compact, high-performance ionizer! ULTRA-COMPACT IONIZER High-frequency AC Method STATIC REMOVER UTRA-COMPACT IONIZER High-frequency AC Method ER-VSERIES Conforming to EMC Directive A new style of charge removal New ultra-compact, high-performance ionizer! Phone:.9.1 - Fax:.73.773 -

More information

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor. Ionizer 2 types of sensors are available. Rapid elimination of static electricity by a feedback sensor Continuously emits ions in accordance with the detected polarity of a workpiece. Supply pressure:

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

Series IZS31. RoHS compliant

Series IZS31. RoHS compliant Ionizer 3 types of the sensors are available. Autobalance sensor [High-precision type] Adjusts ion balance near the workpiece to reduce any interference! New Autobalance sensor [Body-mounting type] Rapid

More information

New ultra-compact, high-performance ionizer!

New ultra-compact, high-performance ionizer! STATIC REMOVER UTRA-COMPACT IONIZER High-frequency AC Method ER-VSERIES Conforming to EMC Directive A new style of charge removal New ultra-compact, high-performance ionizer! AUDIN -, avenue de la malle

More information

16mm. Ionizer Nozzle type. IZN10 Series. Offset voltage ±10 v Slim design: Thickness dimension 16 mm RoHS compliant

16mm. Ionizer Nozzle type. IZN10 Series. Offset voltage ±10 v Slim design: Thickness dimension 16 mm RoHS compliant Ionizer Nozzle type IZN10 Series Dust removal and static neutralization by air blow Eliminates dust clinging to lamp cover. RoHS Spot type static neutralization Prevents electrostatic breakdown of electric

More information

Ready for outdoor use too!

Ready for outdoor use too! Filter/regulator assured for outdoor use New Product Filter/regulator series First in the industry FILTER REGULATOR FOR DOOR USE Ready for outdoor use too! Improved outdoor durability due to the exterior

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

Check Valve Series AK How to Order

Check Valve Series AK How to Order High flow capacity Low cracking pressure:.2mpa Check Valve Series AK How to Order N AK 2 2 Compact and light weight Area Code Japan, Asia, Nil Australia, UK N U.S.A. 2 4 6 Body size /4 /2 /8 2 /4 3 3/8

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the

More information

W1000/W3000/W4000/W8000 Series

W1000/W3000/W4000/W8000 Series Filter and W/W/W/ Series New Series of m elements for dust removal, and m elements for tar removal : / to JIS symbol Specifications Descriptions Appearance W W W nic sensor Pressure Working fluid Max.

More information

Differential Pressure Sensor

Differential Pressure Sensor Differential Pressure Sensor "Cube" Type Differential Pressure Sensor with LED Display Offers High Precision Sensing 31 (1.) x 3 (1.18) x 3 (1.18) mm compact-cube style saves mounting space Easy-to-read

More information

Static Electricity Removal Unit Ionizer Ion Polarity Control Type

Static Electricity Removal Unit Ionizer Ion Polarity Control Type Catalog No.BK-R6 Static Electricity Removal Unit Ionizer Ion Polarity Control Type DTY-BX Series Compact body Body size 5 5 mm [.98.78 in] High voltage wiring not required, with built-in potential sensor

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

ION JET NOZZLE NIH-55

ION JET NOZZLE NIH-55 ION JET NOZZLE NIH-55 INSTRUCTION MANUAL - Read this instruction manual and make sure you thoroughly understand its contents before attempting to operate, inspect or service this product. - The users and

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

Nozzle Type Ionizer. 16 mm x 100 mm x 46 mm 33% reduction. IZN10E Series CAT.ES A

Nozzle Type Ionizer. 16 mm x 100 mm x 46 mm 33% reduction. IZN10E Series CAT.ES A Nozzle Type Ionizer Slim Lightweight Thickness Width Height 16 mm x 100 mm x 46 mm 33% reduction 120 g a 80 g Offset voltage: ±10 V (For energy saving static neutralization nozzle) 16 mm RoHS 46 mm 100

More information

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle

More information

Compact Proportional Solenoid Valve

Compact Proportional Solenoid Valve Compact Proportional Solenoid Valve Series Repeatability: % or less Hysteresis:1% or less Fluid Flow rate control range Note) Series Air, Inert gas to L/min to L/min Note) Varies depending on the model.

More information

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Electro-Pneumatic Regulator/Electronic Vacuum Regulator Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal // series are compatible with various input specifications, including

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor General-purpose Type in a Basic Switch Housing Mounting pitch compatible with that of mechanical basic switch. Wide operating voltage range: 10 to 30 VDC or 90 to 250 VAC. LED

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning Filter Series Series / For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the F.R.L. combination

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Subminiature Sensor Ideal for Narrow Mounting Space Grooved TL-G3D is ideal for high-speed pulse generator and high-speed revolution control. TL-Q2 and TL-Q5 save mounting space

More information

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model Blow Gun Series 20% reduction in power consumption with the SMC Blow gun + S coupler + Coil tube 10% reduction with the Blow gun () only RoHS With cover Extension nozzle Added mm and 150 mm lengths Pressure

More information

Operating instructions Accu Jet

Operating instructions Accu Jet Operating instructions Accu Jet Keep for future use! Ident number: 04.8800.000 Air Line Table of contents 1 Scope of delivery... 4 2 Operator instructions... 5 3 Safety... 6 3.1 Intended use...8 4 Description

More information

Transistor Remote Modules

Transistor Remote Modules Transistor Remote Modules Compact 8-point and 16-point Transistorized Modules Compact (8-point models: 125 x 40 x 50 mm (W x H x D); 16-point models: 150 x 40 x 50 mm (W x H x D)) Two independent supplies

More information

Power Controller. (see note 1) 10 sec

Power Controller. (see note 1) 10 sec Power Controller Single-phase Models EUN Series AC Power Controller with Phase-control System Allows Precise Temperature Control Models with Base-up and Soft-start Functions Available EH Series Phase Control

More information

L1000/L3000/L4000/L8000-W Series

L1000/L3000/L4000/L8000-W Series Lubricator standard white Series L1/L3/L4/L8-W Series Supplies fine oil mist. Port size: 1/8 to 1 JIS symbol Specifications Descriptions L1-W L3-W L4-W L8-W Appearance Working fluid Compressed air Max.

More information

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter Basic performance oriented general vacuum ejector unit Series Nozzle diameter: ø.5, ø, ø1. acuum switch and vacuum break valve, etc. are unitized, so types matching the work purpose is selectable. Features

More information

ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance.

ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance. Electro pneumatic regulator (nozzle flapper method) ER Series Variable controlling air pressure with electric signals ( to V DC / to ma DC) up to.mpa. Booster relay integrated and large flow rate. JIS

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information Flat Inductive Standard Flat s in Many Different Variations Only 6 mm thick yet provides a sensing distance of mm (MC1). Aluminum die-cast models also available. Be sure to read Safety Precautions on page

More information

Miniature Regulator Series ARJ310

Miniature Regulator Series ARJ310 Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates

More information

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

1. Preface For best results, please refer to this manual before using this product. 2. Safety precautions Model Precautions DFS-1 The maximum pressure

1. Preface For best results, please refer to this manual before using this product. 2. Safety precautions Model Precautions DFS-1 The maximum pressure PB97001E-A 2011/06/28 INSTRUCTION MANUAL FOR DIGITAL FLOW SENSOR DFS-*-O/W 1. Preface 2. Safety precautions 3. Installation tips Contents 4. Necessary considerations 5. Description of Model-No. 6. Wiring

More information

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24 Solid State Relays (SSRs) G3PA/G3PB Long Service Life for Circuits that Cycle Frequently D D D D D Built-in heat sink increases life and reliability Voltage turn-on at zero crossing reduces initial inrush

More information

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g Tactile Switch BF Miniature, Space-Saving Tactile Switch Provides Long Service Life and Easy Mounting Extended mechanical/electrical service life: 0 x 0 6 operations for x mm type and x 0 6 operations

More information

Doc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME:

Doc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME: Doc. No. IZ -OML0002-B OPERATION MANUAL PRODUCT NAME: MODEL: Ionizer IZN10 Series Read this operation manual carefully to understand before installation and operation. Pay extra attention on the clause

More information

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1 Proximity Sensor A Series of Spatter-preventing Proximity Sensors with a Teflon-coated Metal Housing Teflon*-coated metal housing endures high tightening torque. Pre-wired and plug-in models are available.

More information

Ordering Information. Text Surface-Mounting Signal Relay G6K

Ordering Information. Text Surface-Mounting Signal Relay G6K Surface-Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm ROHS compliant. Sub-miniature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting.

More information

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter Clean Air Module Series Digital flow switch Regulator ON/OFF valve Restrictor Filter Modularizes clean equipment (Reduced piping man-hours/space-saving). Easily obtains clean air. Built-in one-touch fitting

More information

4 Note 1) Value for communications type. (PROFIBUS DP)

4 Note 1) Value for communications type. (PROFIBUS DP) Electro-Pneumatic Regulator/Electronic Vacuum Regulator Series Stepless control of air pressure proportional to an electrical signal Series // are compatible with various input specifications, including

More information

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing R Basic Switch Style Inductive Prox General-purpose Inductive Prox in a Basic Switch Housing H Mounting pitch compatible with that of a mechanical basic switch H Wide operating voltage range: 10 to 30

More information

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass R Anti-spatter Inductive Prox Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors H Rugged fluoroplastic coated brass barrel withstands high tightening torque H Fluoroplastic resin face prevents weld

More information

MULTISTAGE MICRO EJECTORS

MULTISTAGE MICRO EJECTORS MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]

More information

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,

More information

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g. Tactile Switch BW Tactile Switch with Sealed Construction for Automatic Soldering Sealed construction conforming to IP67 (IEC-6059) provides high reliability in locations exposed to dust or water. Available

More information

Free position locking flat and compact cylinder UFCD Series

Free position locking flat and compact cylinder UFCD Series Space-saving cylinder ensures safety during work in power failures or accidents. Free position locking flat and compact cylinder UFCD Series Free position locking flat and compact cylinder UFCD Series

More information

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue. Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor

More information

HF2 Gauge Installation Guide Scantech

HF2 Gauge Installation Guide Scantech HF2 Gauge Installation Guide 2013-09-13 Scantech 2 Contents Property Note... 5 Conventions...5 Safety Precautions...5 Contact... 7 Placing the Gauge in Its Allocated Space... 9 Positioning the Gauge...9

More information

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors R Long Barrel Inductive Prox E2E2 2-Wire DC Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors H Thick nickel-plated brass barrel for ruggedness H Solid potted internal circuitry withstands

More information

Compact Vacuum Ejector

Compact Vacuum Ejector Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving

More information

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic

More information

Intermittent control timer

Intermittent control timer Contact our sales office regarding a delivery date or a price since this is a special model. P.G.Information (Specialized Product) SP095X-002E P: NU Intermittent control timer IZE110-X238 SMC CORPORATION

More information

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange

Micro Mist Separator. Model. Note) 1 8, , , , , 1. Model/Free Standing Type. Model AMD (2B)JIS 10K FF flange Can separate and remove aerosol state oil mist in compressed air and remove particles such as carbon or dust of more than 0.01 μm. Use this product as a pre-filter for compressed air for precision instruments

More information

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature MEMS Mass Flow Sensor D6F-P A Compact, High-performance Flow Sensor with Dust Segregation Structure. Built in Dust Segregation System (DSS) with cyclone flow structure, diverts particulates from sensor

More information

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal PCB Relay Ultracompact, Ultrasensitive DPDT Relay Compact size and low 5-mm profile. Low power consumption (140 mw for single-side stable, 100 to 300 mw for latching type) and high sensitivity. Low thermoelectromotive

More information

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals Power Relay A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. No contact

More information

Standard Specifications. Model. Port (Bypass lubrication adapter)

Standard Specifications. Model. Port (Bypass lubrication adapter) Booster Lube Series 900 Centralized control of multi-point lubrication Stable oil feeding with a micromist Through the use of a booster, a pressure that is higher than that of the main air passage can

More information

Static Electricity Prevention Equipment

Static Electricity Prevention Equipment Static Electricity Prevention Equipment Antistatic Equipment Don t charge static electricity (Conductivity) Fittings Tubing Pad Speed Controller Electrostatic Removal Equipment Eliminates static electricity

More information

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend Power Controllers GPX Refer to Safety Precautions (page 0). Single-phase Models EUN Series AC Power Controllers with Phase-control System Allow Precise Temperature Control Models with Base-up and Soft-start

More information

Clean Sensing System ZN Series. Advanced Clean-Monitoring for the Manufacturing Field

Clean Sensing System ZN Series. Advanced Clean-Monitoring for the Manufacturing Field Clean Sensing System ZN Series Advanced Clean-Monitoring for the Manufacturing Field Is that booth really clean? Is clean air with a filter enough to maintain a clean environment? Clean measures are not

More information

Electrostatic Fieldmeter

Electrostatic Fieldmeter Electrostatic Fieldmeter Operation Manual Model 521AE Contents Precautions 1 3. Technical Specifications 4 1. Features and Descriptions 1-1. Features 1-2. Descriptions 2 4. Dimensions 5. Warranty 4 5 2.

More information

Operation angle Return angle Output rating Operating voltage Model 40 to to VDC 2.4 to 3.6 VDC D6BN-1P

Operation angle Return angle Output rating Operating voltage Model 40 to to VDC 2.4 to 3.6 VDC D6BN-1P Micro Tilt Sensor D6BN Surface Mounting Tilt Sensor Fits Space- Confined Installations Low profile 2mm with Gull wing surface mount terminals Detect tilting over a range of 40 to 80 degrees in right-andleft

More information

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4 Compact Electro-Pneumatic Regulator Series ITV RoHS How to Order [Option] For single unit and single unit for manifold ITV N Pressure range. MPa. MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector

More information

Pressure Control Equipment

Pressure Control Equipment Control High-pressure Precision General Purpose Special Fluid/Deionized Water (Pure Water) Detection Control Control (General purpose, high-pressure, precision, vacuum, special fluid, deionized water (pure

More information

JDV ATTACHMENT SOLENOID VALVE LIMIT SWITCH FILTER REGULATOR

JDV ATTACHMENT SOLENOID VALVE LIMIT SWITCH FILTER REGULATOR JDV ATTACHMENT SOLENOID VALVE LIMIT SWITCH FILTER REGULATOR SV Series SOLENOID VALVE FEATURES - Can work without oil. - Life is long that can work more than ten million times under the condition of laboratory.

More information

Standard Specifications. Model. Port (Bypass lubrication adapter)

Standard Specifications. Model. Port (Bypass lubrication adapter) Centralized control of multi-point lubrication Stable oil feeding with a micromist Through the use of a booster, a pressure that is higher than that of the main air passage can be supplied. This difference

More information

E2EZ-X2D1-N E2EZ-X2D2-N

E2EZ-X2D1-N E2EZ-X2D2-N Chip-immune Inductive s Detects Objects without Being Influenced by Aluminum or Iron Chips Series now includes M s. s also available. CE Marking for DC -Wire and DC -Wire s. Be sure to read Safety Precautions

More information

Model Number Structure

Model Number Structure Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can

More information

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm Emergency Stop Switch Mounting Aperture of 16 mm Modular construction, easy installation Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, Conforms to EN418

More information

SUB-LINE FILTERS CONTENTS

SUB-LINE FILTERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORES PRODUCTS SUB-LE FILTERS CONTENTS SUB-LE FILTERS Features, Handling Instructions and Precautions 155 Line Filters Specifications,

More information

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment PCB Relay Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment High sensitivity can be driven by digital circuits. Horizontal design allows use in /2-inch PCB racks.

More information

Electronic Ignition Module

Electronic Ignition Module 7 607 Electronic Ignition Module TQO31A27 Electronic ignition module for use with oil or gas burners operating with singleor double-pole ignition. The TQO31A27 and this Data Sheet are intended for use

More information

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key! 655 Door with Key SERIES Related Information General terms and conditions... F-7 General precautions... P.50 PHOTO PHOTO Conforming to Machine & EMC Directives Recognition Certified MEASURE ITY panasonic.net/id/pidsx/global

More information

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure,

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure, Pneumatic components (Electro pneumatic Regulator) Safety Precautions Read this before starting use. Please refer to Intro 43 for general details on the pneumatic components, and to " Precautions" in this

More information

JDV ATTACHMENT SOLENOID VALVE LIMIT SWITCH FILTER REGULATOR

JDV ATTACHMENT SOLENOID VALVE LIMIT SWITCH FILTER REGULATOR JDV ATTACHMENT SOLENOID VALVE LIMIT SWITCH FILTER REGULATOR SV Series SOLENOID VALVE FEATURES - Can work without oil. - Life is long that can work more than ten million times under the condition of laboratory.

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator

Electro-Pneumatic Regulator Electronic Vacuum Regulator Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to New Series Reduced wiring Series

More information

Compact direct acting precision regulator

Compact direct acting precision regulator direct acting precision Components preparation and pressure adjustment / unit CONTENTS Product introduction 68 Safety precautions 6 Discrete (RJB5) 6 Block manifold (MNRJB5) 66 Block configurations 6 Technical

More information

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators

More information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).

More information

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure Miniature Regulator Series ARJ1020F 2 Construction/Dimensions Lock nut M8 X 0.75 Panel screw Panel mounting hole Precautions Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety

More information

Super-Mini Complete with Easy-to-Use Functions. Guided Cylinder. STM Series GUIDED CYLINDER STM SERIES CC-884A 1

Super-Mini Complete with Easy-to-Use Functions. Guided Cylinder. STM Series GUIDED CYLINDER STM SERIES CC-884A 1 Super-Mini Complete with Easy-to-Use Functions Guided Cylinder GUIDED CYLINDER STM SERIES CC-884A 1 Super-Mini Complete with Super-mini Guided Cylinder (ø6, ø10) with free installation and wide variations

More information

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL Compact Electro-pneumatic Regulator Series For single unit and single unit for manifold Pressure range 9 Option. MPa. MPa.9 MPa kpa Option How to Order N Power supply voltage 24 VDC ±% 2 to VDC Option

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

R1000/R3000/R4000/R8000 Series

R1000/R3000/R4000/R8000 Series Regulator R/R/R/R Series Compact pressure gauge integrated type : Rc/ to Rc JIS symbol CAD DATA AVAILABLE. Specifications Descriptions R R R R Appearance Working fluid Max. working pressure Withstanding

More information