Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection

Size: px
Start display at page:

Download "Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection"

Transcription

1 General Systemair thermo fans have been developed for the use in exhaust air systems where media with increased temperatures have to be transported. The special design allows a reliable operation also in systems with higher demands due to increased temperatures or polluted air, for example from kitchens, industrial ovens or in process air. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K variant masters higher demands due to the motor being separated from the air stream. Should regular maintenance/cleaning be necessary, the Systemair ranges KBT/KBR with swing out impeller/door assembly is the ideal solution. For roof exhaust installations we are offering our ranges DNV/DVNI with motor separated from the airstream. Systemair fans are suited to transport media with a continuous temperature of either 100 C or 120 C, depending on the range. Motors Thermo fans are equipped with IEC standard motors, with some exceptions speed controllable by voltage. All motors with protection class IP 54 and insulation class F. Motors with thermal contacts and extended leads for connection to a Systemair motor protection unit. Standard execution ASF/KB Flexible connection KBT/KBR WSD Weather roof for motor ASF/KB Flexible connection WBK Wall mounting bracket FGV-K Flexible connection UGS MUB-K FGV-K Flexible connection 163

2 KBT Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBT fans have impellers manufactured from galvanised sheet steel with forward-curved blades. The casing is manufactured from double-skinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBT fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame.to protect the motors from overheating the KBT fans have integral thermal contacts with external leads for connection to a motor protection device. KBT 160E4 KBT 160DV KBT 180E4 KBT 200E4 Voltage/Frequency V/50 Hz Phase ~ Power at shaft W Current A 1,11 0,57 1,11 5,1 Maximum air flow m 3 /s (m 3 /h) 0,23 (830) 0,25 (900) 0,39(1240) 0,54(1950) R.p.m. min Max. temp of transp. air C Max. temp of transp. air when speed-controlled C Sound pressure level at 4/10 m db(a) 31/23 31/23 34/26 37/29 Weight kg Insulation class F F F F Enclosure class IP 54 IP 54 IP54 IP54 Capacitor μf Motor protection S-ET 10 STDT 16 S-ET 10 S-ET 10 Speed control, five step Transformer RTRE 1,5 RTRD 2 RTRE 1,5 RTRE 7 Speed control, five step high/low Transformer REU 1,5 + S-ET 10 RTRDU 2 REU 1,5 + S-ET 10 REU 7 + S-ET 10 Speed control, D/ two step 400 V Transformer - S-DT2 SKT - - Wiring diagram p A B C D E øg H J KBT , KBT , KBT ,

3 WSD p. 488 ASF/KB p. 489 WBK p. 489 ALS/KBT p. 489 KBT 160E4 L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,12 m 3 /s, P s = 120 Pa KBT 160DV = Star connection; low speed L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,14 m 3 /s, P s = 134 Pa REV p. 463 S-ET p. 464 STDT p. 464 REU p. 454 KBT 180E4 L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,21 m 3 /s, P s = 210 Pa KBT 200E4 L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,26 m 3 /s, P s = 280 Pa RTRE p. 454 RTRDU/RTRD p

4 KBT Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBT fans have impellers manufactured from galvanised sheet steel with forward-curved blades. The casing is manufactured from double-skinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBT fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame. To protect the motors from overheating the KBT fans have integral thermal contacts with external leads for connection to a motor protection device. KBT 200DV KBT 225E4 KBT 225DV KBT 250E4 Voltage/Frequency V/50 Hz Phase ~ Power at shaft W Current A 1,88 5,1 2,3 10,4 Maximum air flow m 3 /s (m 3 /h) 0,58 (2100) 0,76 (2750) 0,76 (2750) 1,08 (3900) R.p.m. min Max. temp of transp. air C Max. temp of transp. air when speed-controlled C Sound pressure level at 4/10 m db(a) 37/29 41/33 41/33 45/37 Weight kg Insulation class F F F F Enclosure class IP 54 IP 54 IP 54 IP 54 Capacitor μf Motor protection STDT 16 S-ET 10 STDT 16 AWE-SK Speed control, five step Transformer RTRD 2 RTRE 7 RTRD 4 - Speed control, five step high/low Transformer RTRDU 2 REU + S-ET 10 RTRDU 4 - Speed control, D/ two step 400 V Transformer S-DT2 SKT - S-DT2 SKT - Wiring diagram p A B C D E øg H J KBT , KBT , KBT

5 WSD p. 488 ASF/KB p. 489 WBK p. 489 ALS/KBT p. 489 KBT 200DV = Star connection; low speed L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,29 m 3 /s, P s = 280 Pa KBT 225E4 L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,49 m 3 /s, P s = 285 Pa S-DT2 SKT p. 463 REV p. 463 S-ET p. 464 STDT p. 464 REU p. 454 = Star connection; low speed KBT 225DV L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,37 m 3 /s, P s = 382 Pa KBT 250E4 Min. static back pressure: 180 Pa L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,56 m 3 /s, P s = 500 Pa RTRE p. 454 RTRDU/RTRD p

6 KBT Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBT fans have impellers manufactured from galvanised sheet steel with forward-curved blades. The casing is manufactured from double-skinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBT fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame. To protect the motors from overheating the KBT fans have integral thermal contacts with external leads for connection to a motor protection device. KBT 250DV KBT 280DV Voltage/Frequency V/50 Hz Phase ~ 3 3 Power at shaft W Current A 4,3 5,8 Maximum air flow m 3 /s (m 3 /h) 1,11 (4000) 1,22 (4400) R.p.m. min Max. temp of transported air C Max. temp of transported air when speed-controlled C Sound pressure level at 4/10 m db(a) 45/37 48/40 Weight kg Insulation class F F Enclosure class IP 54 IP 54 Capacitor μf - - Motor protection STDT 16 STDT 16 Speed control, five step Transformer RTRD 7 RTRD 7 Speed control, five step high/low Transformer RTRDU 7 RTRDU 7 Speed control, D/ two step 400 V Transformer S-DT2 SKT S-DT2 SKT Wiring diagram p A B C D E øg H J KBT KBT

7 WSD p. 488 ASF/KB p. 489 WBK p. 489 ALS/KBT p. 489 KBT 250DV = Star connection; low speed L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,67 m 3 /s, P s = 400 Pa KBT 280DV = Star connection; low speed Min. static back pressure: 240 Pa L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,60 m 3 /s, P s = 630 Pa S-DT2 SKT p. 463 REV p. 463 S-ET p. 464 STDT p. 464 REU p. 454 RTRE p. 454 RTRDU/RTRD p

8 KBR 280 Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBR fans have impellers manufactured from galvanized steel with backward-curved blades and external rotor motors. The KBR casing is manufactured from doubleskinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBR fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame. To protect the motors from overheating the KBR fans have integral thermal contacts with external leads for connection to a motor protection device. KBR 280D2 KBR 280D2-4 KBR 280DV Voltage/Frequency V/50 Hz Phase ~ Power at shaft *) W / Current A 2,2 1,2/0,33 1,39 Maximum air flow m 3 /s (m 3 /h) 0,8 (2900) 0,8 (2900)/0,42 (1520) 0,42 (1520) R.p.m. min / Max. air speed on outlet m/s 13,5 13,5/7,2 7,2 Max. temp of transported air C Max. temp of transported air when speed-controlled C Sound pressure level at 4/10 m db(a) 44/36 44/36-33/25 33/25 Weight kg Insulation class F F F Enclosure class IP 55 IP 55 IP 54 Motor protection - - STDT 16 Speed control, five step Transformer - - RTRD 2 Speed control, five step high/low Transformer - - RTRDU 2 Speed control, D/ two step 400 V Transformer - - S-DT2 SKT Wiring diagram p *) Shaft radiated power IEC standard engine To guarantee the function of the installation without any problems, we advise to rate the fan in that way that the flow speed on the outlet don t rise above 10 m/s. A B C D E øg H I J L KBR , ,

9 KBR 280D2 300 KBR 280DV WSD p pol ASF/KB p pol WBK p ,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0, ,1 0,2 0,3 0,4 0,5 0, KBR 280D2 Hz Tot k 2k 4k 8k L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,42 m 3 /s, P s = 800 Pa KBR 280DV Hz Tot k 2k 4k 8k L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,02 m 3 /s, P s = 220 Pa ALS/KBT p. 489 S-DT2 SKT p. 463 REV p. 463 STDT p. 464 RTRDU/RTRD p

10 KBR 315DV-355E4 Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBR fans have impellers manufactured from aluminium with backward-curved blades. The KBR casing is manufactured from double-skinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBR fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame. To protect the motors from overheating the KBR fans have integral thermal contacts with external leads for connection to a motor protection device. KBR 315DV KBR 315DZ KBR 355E4 KBR 355E4/K Voltage/Frequency V/50 Hz Phase ~ Power at shaft *) W Current A 1,39 3,40 2,10 2,10 Air flow m 3 /s (m 3 /h) 0,61 (2200) 1,10 (3950) 0,97 (3500) 0,78 (2800) Max. air speed at outlet m/s 7,8 14,1 9,8 7,9 R.p.m. min Max. temp of transported air C Max. temp of transported air when speed-controlled C Sound pressure level at 4/10 m db(a) 36/28 51/43 44/33 42/31 Weight kg Insulation class F F F F Enclosure class IP 54 IP 54 IP 54 IP 54 Capacitor μf Motor protection STDT 16 STDT 16 S-ET 10 S-ET 10 Speed control, five step Transformer RTRD 2 RTRD 4 RTRE 3 RTRE 3 Speed control, five step high/low Transformer RTRDU 2 RTRDU 4 REU 3 + S-ET 10 REU 3 + S-ET 10 Speed control, D/ two step 400V S-DT2 SKT S-DT2 SKT - - Wiring diagram p *) Shaft radiated power IEC standard engine To guarantee the function of the installation without any problems, we advise to rate the fan in that way that the flow speed on the outlet don t rise above 10 m/s. A B C D E øg H I J L KBR , , KBR , ,

11 WSD p. 488 ASF/KB p. 489 WBK p. 489 ALS/KBT p. 489 KBR 315DV = Star connection; low speed L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,38 m 3 /s, P s = 250 Pa KBR 315DZ = Star connection; low speed L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,46 m 3 /s, P s = 1276 Pa S-DT2 SKT p. 463 REV p. 463 S-ET p. 464 STDT p. 464 REU p. 454 KBR 355E4 L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,42 m 3 /s, P s = 465 Pa KBR 355E4/K L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,42 m 3 /s, P s = 320 Pa RTRE p. 454 RTRDU/RTRD p

12 KBR 355DV-DZ Max temperature of transported air 120 C Speed-controllable Integral thermal contacts Low sound level The KBR fans have impellers manufactured from aluminium with backward-curved blades and external rotor motors. The KBR casing is manufactured from double-skinned galvanised sheet steel and is insulated with 50 mm mineral wool. The KBR fans have a swing-out door for easy inspection and service. The direction of the door opening can easily be changed from left to right at site. The fan is isolated from the casing via connectors and anti-vibration dampers are incorporated into the base frame. To protect the motors from overheating the KBR fans have integral thermal contacts with external leads for connection to a motor protection device. KBR 355DV KBR 355DV/K KBR 355DZ KBR 355DZ/K Voltage/Frequency V/50 Hz Phase ~ Power at shaft *) W Current A 1,39 1,39 6,5 5,00 Air flow m 3 /s (m 3 /h) 1,06 (3800) 0,81 (2900) 1,97 (7100) 1,53 (5500) Max. air speed at outlet m/s 10,7 8,2 19,9 15,5 R.p.m. min Max. temp of transported air C Max. temp of transported air when speed-controlled C Sound pressure level at 4/10 m db(a) 41/33 41/33 54/46 54/46 Weight kg Insulation class F F F F Enclosure class IP 54 IP 54 IP54 IP54 Motor protection STDT 16 STDT 16 STDT 16 STDT 16 Speed control, five step Transformer RTRD 2 RTRD 2 RTRD 7 RTRD 7 Speed control, five step high/low Transformer RTRDU 2 RTRDU 2 RTRDU 7 RTRDU 7 Speed control, D/ two step 400 V Transformer S-DT2 SKT S-DT2 SKT S-DT2 SKT S-DT2 SKT Wiring diagram p *) Shaft radiated power IEC standard engine To guarantee the function of the installation without any problems, we advise to rate the fan in that way that the flow speed on the outlet don t rise above 10 m/s. 174

13 WSD p. 488 ASF/KB p. 489 WBK p. 489 ALS/KBT p. 489 KBR 355DV = Star connection; low speed Mid-frequency band, H L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,69 m 3 /s, P s = 320 Pa = Star connection; low speed KBR 355DV/K Mid-frequency band, H L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,32 m 3 /s, P s = 398 Pa S-DT2 SKT p. 463 REV p. 463 KBR 355DZ = Star connection; low speed L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,83 m 3 /s, P s = 1800 Pa = Star connection; low speed KBR 355DZ/K L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,72 m 3 /s, P s = 1431 Pa STDT p. 464 RTRDU/RTRD p

14 MUB DV-K2-500DV-K2 Motor outside of the air stream Speed-controllable Modular system Integral thermal contacts Low sound level Maintenance-free and reliable All MUB-K2 fans have impellers with backward curved blades, manufactured from aluminium, and IEC standard motors, which can be speed controlled by transformer, except size 630-D4. Motors are outside the air stream. The casing consists of an aluminium frame with fiberglass reinforced plastic corners and double skin, galvanised steel panels with a 20 mm mineral wool insulation. Panels are removable, allowing flexible ventilation solutions. With quick-lock access door. The MUB casing is equipped with a grease tray under the impeller and a protection guard at the motor side. An isolator switch is mounted on the casing. All MUB-K2 motors (except 630D4) are D/ connected for two speed operation. Motor protection by thermal contacts, to be connected to an external motor protection device. Standard execution, seen in airflow direction: service door left, top outlet. The MUB-K2 fans are delivered to 90 air direction airflow. MUB DV-K2 450DV-K2 500DV-K2 Voltage/Frequency V/50 Hz Phase ~ Power at shaft W Current A 1,40 2,50 4,3 Maximum air flow m 3 /h R.p.m. min Max. temp. of transported air C Max. ambient temp. C Sound pressure level at 3 m * db(a) Weight kg Insulation class, motor F F F Enclosure class, motor IP 54 IP 54 IP 54 Motor protection STDT 16 STDT 16 STDT 16 Speed control, five-step Transformer RTRD 2 RTRD 4 RTRD 7 Speed control, five-step high/low Transformer RTRDU 2 RTRDU 4 RTRDU 7 Speed control, D/ two step 400V S-DT2 SKT S-DT2 SKT S-DT2 SKT Wiring diagram p * According to 20 m 2 Sabine A B C ød øe F MUB MUB MUB

15 FGV p. 488 SRKG p. 488 UGS p. 488 MUB DV-K2 Hz Tot k 2k 4k 8k L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 0,56 m 3 /s, P s = 323 Pa MUB DV-K2 Hz Tot k 2k 4k 8k L wa Inlet db(a) L wa Outlet db(a) LwA SurroundingdB(A) Measuring point: q v = 0,81 m 3 /s, P s = 325 Pa STDT p. 464 RTRD p. 455 MUB DV-K2 Hz Tot k 2k 4k 8k L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 1,40 m 3 /s, P s = 434 Pa RTRDU p. 455 S-DT2SKT p

16 MUB DV-K2-630D4-K2 Motor outside of the air stream Speed-controllable Modular system Integral thermal contacts Low sound level Maintenance-free and reliable All MUB-K2 fans have impellers with backward curved blades, manufactured from aluminium, and IEC standard motor, which can be speed controlled using frequency controller. Motors are outside the air stream. The casing consists of an aluminium frame with fiberglass reinforced plastic corners and double skin, galvanised steel panels with a 20 mm mineral wool insulation. Panels are removable, allowing flexible ventilation solutions. With quick-lock access door. The MUB casing is equipped with a grease tray under the impeller and a protection guard at the motor side. An isolator switch is mounted on the casing. Motor protection by thermal contacts, to be connected to an external motor protection device. Standard execution, seen in airflow direction: service door left, top outlet. The MUB-K2 fans are delivered to 90 air direction airflow. MUB DV-K2 630D4-K2 Voltage/Frequency V/50 Hz Phase ~ 3 3 Power at shaft W Current A 5,8 9,5 Maximum air flow m 3 /h R.p.m. min Max. temp. of transported air C Max. ambient temperature C Sound pressure level at 3 m * db(a) Weight kg Insulation class, motor F F Enclosure class, motor IP 54 IP 54 Motor protection STDT 16 STDT 16 Speed control, five-step Transformer RTRD 7 - Speed control, five-step high/low Transformer RTRDU 7 - Speed control, D/ two step 400V S-DT2 SKT - Wiring diagram p * According to 20 m 2 Sabine A B C ød øe F MUB MUB

17 FGV p. 488 SRKG p. 488 UGS p. 488 MUB DV-K2 Hz Tot k 2k 4k 8k L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 2,25 m 3 /s, P s = 565 Pa MUB D4-K2 Hz Tot k 2k 4k 8k L wa Inlet db(a) L wa Outlet db(a) L wa Surrounding db(a) Measuring point: q v = 1,95 m 3 /s, P s = 911 Pa STDT p

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable KD High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable Electrical accessories S-ET p. 341 The KD series have external rotor

More information

Single-inlet centrifugal fans

Single-inlet centrifugal fans CE 200-280 4-pole Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable CE fans are easy to install. Fans in this series have impellers with forward-curved

More information

KV sileo 100 M. Circular duct fans. Circular duct fans

KV sileo 100 M. Circular duct fans. Circular duct fans KV sileo 100 M Speed-controllable Integral thermal contacts Can be installed in any position Can be installed outdoors Maintenance-free and reliable Electrical accessories RE p. 20 The K series is designed

More information

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence Explosion proof fans General Systemair explosion proof fans have been developed to be used in effective supply and exhaust air systems allocated to category 2 (zone 1) and category 3 (zone 2) in explosion

More information

Max. airflow m 3 /s Diam. min. Diam. max

Max. airflow m 3 /s Diam. min. Diam. max Axial Fans Max. airflow m 3 /s Diam. min Diam. max 1% adjustable motor Assembly, any position Reversible (3% Reduction) Page Number AW AR AW.97 2 3 * * 13 AR.97 2 3 * * 134 ZSP 2.9 315 5 * * 13 ZAP 13.89

More information

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h SOUND-INSULATED KITCHEN FAN Series device. The impeller is mounted on the motor shaft and is balanced statically and dynamically. The motor has F class motor winding insulation and ingress protection rating.

More information

KF T120. Kitchen fans. Wentylatory kuchenne KITCHEN FANS

KF T120. Kitchen fans. Wentylatory kuchenne KITCHEN FANS KF T120 Kitchen fans Wentylatory kuchenne Kitchen exhaust units are used for installation where the air is slightly greasy or the air temperature is up to 120 C. Unit has a swing-out door for easy inspection

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

MegaBox Product-specific information

MegaBox Product-specific information MegaBox Product-specific information Application Noise-encapsulating centrifugal fans with retractable motor impeller unit and motor located outside the air flow Suitable for rough operating conditions

More information

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE Roofmaster STEC non-insulated version - Technical Catalogue 3 CONTENTS GENERAL DESCRIPTION Application/specification...4 Features...4

More information

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710. Square Duct Fans - ESTOC Range Features Sizes from 355 to 71 mm diameter Air flow 1,9 m 3 /h (5.2 m 3 /s) Static pressures up to 115 Pa Maximum temperature from +4 C to +7` C (depending on the model) Adjustable

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. VKAP 3. Features Power supply Temperature range Diameter - 1 mm to 315 mm; Airflow up to 137 m 3 /h; Easily mounted in any position; Backward-curved impeller; Low ambient temperatures; Cost-effective.

More information

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts LOW PRESSURE CENTRIFUGAL FANS Series Range of double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel. All the models are fitted with forward curved centrifugal

More information

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller. VKS VKSA Features Power supply Temperature range 400x200 mm to 1000x500 mm flanges; Airflow up to 9200 m 3 /h; Can be mounted on floors, walls or ceilings; Forward-curved galvanized steel impeller; Cost-effective;

More information

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular

More information

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille. Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories,

More information

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation

More information

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases. VSV VSVI Features Power supply Temperature range Sizes Construction Installation Speed control options 9 sizes; Airflow up to 5300 m 3 /h; Vertical exhaust; Backward-curved plastic or galvanized steel

More information

Circular Duct Fan prioair

Circular Duct Fan prioair Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Circular Duct Fan prioair More performance. Less energy consumption. The new EC circular duct

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity 400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,

More information

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot CENTRIFUGAL IN-LINE FANS Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a pre-wired wiring junction

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases. VSA 3. ROOF FAS Features Power supply Temperature range 4 sizes; Airflow up to 117 m 3 /h; Horizontal exhaust; Backward-curved impeller; ost-effective. 23V/5Hz/1f. From -4 up to 4/65. Sizes 19 S, 19, 22

More information

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF-ATEX ROOF FAN» Technical CATALOGuE 2 STEF-ATEX Roofmaster - Technical Catalogue Contents General description Application/specification... 3 Features...

More information

CENTRIFUGAL IN-LINE FANS VENT Series

CENTRIFUGAL IN-LINE FANS VENT Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a prewired wiring junction box and a robust mounting foot.

More information

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series Cabinet fans manufactured from galvanised steel sheet with double thickness side panels lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M0). Circular duct connection flange on the

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard

More information

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance GENERAL VENTILATOR A quality product suitable for general residential application. proprietary made and compact design fan is designed

More information

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers. ACOUSTIC CABINET FANS Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic

More information

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information. In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V

More information

ACOUSTIC CABINET FANS CVAB / CVAT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series Range of in-line cabinet fans, manufactured from galvanised steel sheet with double thickness side panels internally lined with 17 mm thickness of fireproof fibreglass acoustic insulation (M). All models

More information

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355. Tube Fans - ROPERA Range Features 1 mm to 355 mm diameter Air flow 234 m 3 /h (.65 m 3 /s) Static pressures up to 92 Pa Casing - galvanized sheet steel Backward curved impeller Easy electrical connection

More information

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced. LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a

More information

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller CSXR CSXRT CJSXR CSXR: Belt-driven single inlet centrifugal fans with shaft outlet and backward-curved impeller CSXRT: Belt-driven single inlet centrifugal fans fitted with electric motors, a set of pulleys

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL

More information

ROOFMASTER STEF ROOF FAN

ROOFMASTER STEF ROOF FAN Air Comfort Air movement Roof fans ROOFMASTER STEF ROOF FAN» Technical CATALOGuE Contents ROOFMASTER STEF...3 Performance Data...4 Performance Table...6 General description...8 Fan Chart-explanation and

More information

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Square Duct Fans - ESTOC TARGE Range Features Sizes from 55 to 6 mm diameter Air flow 21, m /h (5.8 m /s) Static pressures up to 145 Pa Maximum temperature up to 11 C Controllable external rotor motors

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000. Circular Box Fans - DAISHO EC Range Features 125mm to 1mm Air flow 1,25 m 3 /h (3.5m 3 /s) Static pressures up to 125 Pa Maximum temperature range 6ºC Suitable for variable or constant pressure systems

More information

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil Integreret Combi Cooler system Energieffektiv ventilation og køling FCUA Fancoil DESCRIPTION The FCU(A,F) fan coil unit is a highperformance, cost-effective and compact solution for the cooling of technical

More information

Axial fans. What s more, non-stock models are normally available within two weeks.

Axial fans. What s more, non-stock models are normally available within two weeks. Axial fans 7 sees the introduction of a new production line at Xpelair s Peterborough plant for the Scimitar Sickle blade fans in Plate, Short Case and Roof versions up to 63mm. Scimitar will join an impressive

More information

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code Tubes and ox Fans Duct Fans - ESTOC EC Range Features Sizes from 55 to 6 mm diameter ir flow 19, m /h (4. m /s) Static pressures up to 84 Pa Maximum temperature up to 6 C Controllable external rotor motors

More information

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS SOUND-INSULATED FANS Series Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7 m 3 /h Purpose KSB fan design allows to use them in supply and exhaust ventilation systems

More information

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G THT/HATCH High-powered ventilators with motorised opening and equipped with a roof fan, for smoke extraction in the event of a fire, 400ºC/2h High-powered ventilators with roof fan and motorised opening.

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Features and Benefits Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 P65 service isolator Guard

More information

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series 0 017982 603075 A P P L I C A T I O N S Range of plate mounted axial fans manufactured from high grade galvanised steel

More information

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

IN-LINE DUCT FANS MIXVENT-TD Fan Systems IN-LINE DUCT FANS MIXVENT-TD Fan Systems NEW TD-EXTRACTOR KIT (see page 175) MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment

More information

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER Roof Extract Fans Ventilation Hoods Smoke Extract Fans DV DLH ER Summary... Seite Roof Extract Fans DV Product review... Summary data sheet...

More information

CK, LPK, LPKB. Duct fans with circular connection.

CK, LPK, LPKB. Duct fans with circular connection. CK, LPK, LPKB Duct fans with circular connection 1 www.ostberg.com Contents CK CIRCULAR DUCT FAN............5 CK 100 A/C 230 V/50 Hz........6 CK 125 A/C 230 V/50 Hz........6 CK 150 B/C 230 V/50 Hz........7

More information

In-line rectangular fans. Technical Catalogue

In-line rectangular fans. Technical Catalogue In-line rectangular fans Technical Catalogue Overview IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning

More information

HIGH-POWERED VENTILATORS

HIGH-POWERED VENTILATORS HIGH-POWERED VENTILATORS WITH ROOF FANS 400ºC/2h The THT/HATCH series was designed using high-powered ventilator technology for smoke extraction in the event of a fire, and is equipped with THT series

More information

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning systems. They

More information

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT BACKWARD CURVED CENTRIFUGAL FANS Series The CHVB-CHVT range is suitable for many general ventilation applications where high system resistances are present; i.e. systems with filters, dampers etc. Range

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series asy to install Supports to facilitate installation in the roof. XTRACTION (type B) SUPPLY (type A) High quality steel sleeve nsuring the long life of the fan. Range of axial roof fans with horizontal air

More information

ROOF FAN ROOFMASTER STEC

ROOF FAN ROOFMASTER STEC AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...

More information

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315 Tube Fans - ESPADA Range Features mm to 315 mm diameter Air flow 18 m 3 /h (.5 m 3 /s) Static pressures up to 72 Pa Plastic cased centriugal fan Low noise levels Completely corrosion resistant Easy electrical

More information

MAJAX-2 GENERAL SPECIFICATION

MAJAX-2 GENERAL SPECIFICATION MAJAX-2 GENERAL SPECIFICATION Majax-2 axial flow fans are manufactured in diameters ranging from 315mm to 2000mm (available in 2250mm on request), and incorporate manually adjustable pitch aluminium bladed

More information

GigaBox centrifugal fans Product specific information

GigaBox centrifugal fans Product specific information GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,

More information

Plate mounted axial flow fans HXBR / HXTR Series

Plate mounted axial flow fans HXBR / HXTR Series Plate mounted axial flow fans manufactured from high grade galvanised steel and provided with a Sickle blade impeller, low sound level, protected against corrosion by cataforesis primer and a polyester

More information

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Explanation of AR Series Ventilator Products. Fan type code D S AR AE Series Axial Fan Explanation of Series Ventilator Products Fan type code 450-7 /26 D -2 F400 Smoke Extract Fan 400 C, 300 C Number of Poles D S Three Phase Single Phase AE AE Features and construction

More information

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller. TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7 CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound

More information

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance A P P L I C A T I O N S PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series Range of plate mounted axial fans manufactured from high grade galvanised steel and provided with

More information

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power CAS CAS: High pressure, single inlet centrifugal fans with sheet steel casing and impeller : High pressure, single inlet centrifugal fans with sheet steel casing and impeller, fitted with acoustic attenuators

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

Unobox units with backward curved centrifugal impellers

Unobox units with backward curved centrifugal impellers Unobox Fans Unobox units with backward curved centrifugal impellers Type Code UNO 67-450 -4 E W Unobox Box size 50=500mm ; 67=670mm 80=800mm ; 102=1020mm Impeller diameter Number of poles D - Three Phase

More information

KUB T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Extractor de cocina KITCHEN FANS

KUB T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Extractor de cocina KITCHEN FANS Kitchen fans Caisson de ventilation Küchenabluftboxen Extractor de cocina Kitchen exhaust units are used for installation where the air is slightly greasy or the air temperature is up to 120 C. Typical

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalogue air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalogue Contents GENERAL Description and survey chart Application... 3 General Survey

More information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems MIXVENT TD / MIXVENT TD-T MIXVENT TDx2 ACCESSORIES Description Range Construction The MIXVENT system has been designed to compliment the MIXVENT-TD range

More information

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows HTMH Multifunctional roof fans for large flows Multifunctional roof fans, highly robust construction, for large flows Fan: Painted galvanised sheet steel base plate Turnable impellers cast aluminium. Protection

More information

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series Range of low profile in-line mixed flow duct fans manufactured in tough reinforced plastic (from 16 to 8 models) or with metal casing steel finished in a tough epoxy-polyester paint coating (from 1 to

More information

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

DVAX-ARS. Roof-mounted unit for mechanical smoke extract Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans DVAX- Roof-mounted unit for mechanical smoke extract 2 DVAX DVAX- Roof-mounted axial fan unit

More information

Heat recovery units type GTDHR

Heat recovery units type GTDHR GTDHR Double flux - 4 m3/h AC 23V type GTDHR Double flux heat recovery unit high efficiency 9%. The range consists of 5 sizes and 6 types for air flow from up to 4 m³/h. Application Ventilation and heat

More information

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS Cabinet Fan SV-1 INDEX INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART pages 01 02 03 04 DIMENSION SHEET - SINGLE CABINET FANS DIMENSION SHEET - TWIN CABINET FANS PERFORMANCE GRAPH WIRING

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting. AXIAL FANS Series VENTS OV Series VENTS OVK Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 11900 m 3 /h for wall mounting. Low pressure axial fans in the steel casing

More information

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes Comfort ventilation Very wide flow rate range : 0.11 to 9.72 m 3 /s Standard version with lacquered finish casing APPLICATION ventilation are designed for the ventilation of tertiary or industrial buildings,

More information

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series False-ceiling models CADB/T-HE 4 to 33 Heat Recovery Compact heat recovery unit with high-efficiency (up to 93%) counter-flow heat exchanger, EUROVENT certified. The casing is made from plasticised galvanised

More information

MIRUVENT. Power roof ventilator with 27 different airflow variants up to 24,000 m 3 /h

MIRUVENT. Power roof ventilator with 27 different airflow variants up to 24,000 m 3 /h MIRUENT Power roof ventilator with 27 different airflow variants up to 24, m 3 /h General MIRUENT is a power roof ventilator with a casing made of corrosion-resistant aluminium The power roof ventilator

More information

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones. CJTHT Axial fans 400ºC/2h and 300ºC/2h With soundproofed box Extraction units with axial fans to work inside fire danger zones. Fan: Sheet steel long casing fan. Galvanised sheet steel structure with thermal

More information

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Dynamically-balanced impellers with extremely robust cores CMP T 5.5 Medium pressure, single inlet centrifugal fans with sheet steel casing and impeller Fan: Sheet steel casing. Forward-curved impeller made of galvanised sheet steel. 38-2M model casing in cast aluminium.

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series TD-SILENT ECOWATT - MODELS 5 to TD-SILENT ECOWATT - MODELS AND At 5% of full speed fan power consumption is reduced by 7% Low profile Mixed-flow fans with sound-absorbent insulation, extremely quiet, fan

More information

Accessories. Controllers / Sensors. Duct Heaters / Cooling Coils

Accessories. Controllers / Sensors. Duct Heaters / Cooling Coils Duct Heaters / Cooling Coils Filter boxes / Filters Fan to Duct Fittings / Misc CB FGR PRK REP VBC FFR WSD RET CWK FFK WSD KBT DSG RB FFS WBK DTV RBM EAAF ALS-KBT ETFV VBR EAPF SMF RS Controllers / Sensors

More information

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan Product information - Version 3 DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan Overskrift placering Table of contents Choice of motor... 4 DTV roof fans... 5 - Technical specifications

More information

Hison Axial Flow Fans

Hison Axial Flow Fans Hison Axial Flow Fans Introduction Hison Marine Axial Flow Fans, formerly know as Howden Fans are manufactured to international Quality Standard. Axial flow fans are available from sizes 35mm to 18mm diameter,

More information

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS BSB 03.06-01 BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS Description Construction Fans are not

More information

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting AXIAL FANS Series VENTS OV Series VENTS OVK Series VENTS Low pressure axial fans in the steel casing with the air capacity up to 122 m 3 /h for wall mounting Low pressure axial fans in the steel casing

More information

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Multifunctional 400ºC/2h and 300ºC/2h roof fans HTMF Multifunctional 400ºC/2h and 300ºC/2h roof fans Multifunctional 400ºC/2h ceiling fans to work inside fire danger zones, designed for smoke extraction in industrial or similar buildings. 0370-CPR-0544

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

DIRECT-AIR ILB / ILT Series Rectangular duct fans

DIRECT-AIR ILB / ILT Series Rectangular duct fans IN-LINE DUCT FAN Series Rectangular duct fans Range of in-line rectangular duct fan manufactured from galvanised steel sheet and provided with an inspection cover that can be removed to access the motor/impeller

More information

Kitchen exhaust fan GLEB

Kitchen exhaust fan GLEB Kitchen exhaust fan GLEB Contents General description...3 Quick selection...5 Design description...5 Material and design...6 Fan impeller...6 Motor...6...6 Quality...6 Specification...6 Technical data

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

CYCLONE F 400 smoke extraction casing

CYCLONE F 400 smoke extraction casing Fire protection CYCLONE F smoke extraction casing Presentation of the CYCLONE F range (12) WHY CHOOSE A CYCLONE F? In order to fulfil the requirements of the CE markings (EN 1211-3 and the French governmental

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information