ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

Size: px
Start display at page:

Download "ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB"

Transcription

1 Data sheet ELIMINATOR Hermetic bi-flow filter drier s DMB and DCB Hermetic bi-flow filter driers, types DMB and DCB are for use in liquid lines on heat pumps. Hermetic bi-flow filter driers have built-in check valves which ensure that refrigerant liquid always flows through the filter driers from the outer side of the filter core towards the center. Thus all dirt particles are retained irrespective of flow direction. DMB and DCB filter driers ensure fast and effective adsorption of moisture as well as organic and inorganic acids. When building heat pump systems, the use of bi-flow filters can, depending on the type of system, save up to ten solder connections. This reduces production costs and the number of potential leakage points. Available with flare and solder (cu-plated steel) connections. For other connections please contact your Danfoss Sales Representative. Features The Core type DMB 00% 3Å Molecular Sieve core High drying capacity minimizing the risk of acid formation (hydrolysis) Recommended for use with HFO, HC, HFC and HCFC refrigerants Will not deplete oil additives The Core type DCB 80% 3Å Molecular Sieve with 20% activated alumina Perfect core blend for systems that operate at high condensing temperatures and require high drying capacity Recommended for use with HFO, HC, HFC and HCFC refrigerants The Shell PED approved for PS 46 bar Available with flare and solder (cu-plated steel) connections Optimum flow characteristics and dirt retention The check valves are not sensitive to dirt and give minimum restriction, irrespective of flow direction The Filter Effective dirt removal to 25 μm No dirt released by reversing the flow direction Available in sizes 8 30 cubic inches Danfoss DCS (za) DKRCC.PD.ED0.D H098

2 Approvals UL US, file no. SA 6398 PED 97/23/EC - a3p3 Compliant with ATEX hazard zone 2 Note: Only solder versions (cu-plated / pure copper) and connection sizes below 25 mm are approved for flammable refrigerants now. Technical data Surface and volume Filter Solid core surface Solid core volume Filter drier volume (shell volume) Filter drier volume (net volume) [cm 2 ] [cm 3 ] [l] [l] DMB/DCB DMB/DCB DMB/DCB Acid capacity Filter Acid capacity ) [g] DCB DCB 6.29 DCB ) Adsorption capacity of oleic acid at 0.05 TAN (Total Acid Number). Solder connection (cu-plated steel) Temperature range: C Dirt retention Particles > 25 μm Technical data and capacities Drying and liquid capacity, type DMB Drying capacity [kg] refrigerant ) Liquid capacity [kw] 2 ) Max. R34a R404A R507 R22 R407C R40A Working Pressure [ C] R34a R404A R507 R22 R407C R40A PS [bar] DMB 082/082s DMB 083/083s DMB 084/084s DMB DMB 63/63s DMB 64/64s DMB 65/65s DMB DMB 304/304s DMB 305/305s DMB 307s ) Drying capacity is based on following moisture content test standards before and after drying: R34a: ppm W R404A, R507: ppm W R407C: ppm W R40A: ppm W R22: ppm W In accordance with ARI ) Given in accordance with ARI for t e= -5 C t c= 30 C Δp = 0.07 bar For technical data on other refrigerants, please contact your Danfoss Sales Representative Danfoss DCS (za) DKRCC.PD.ED0.D H098 2

3 Technical data and capacities Drying and liquid capacity, type DCB Drying capacity [kg] refrigerant ) Liquid capacity [kw] 2 ) Max. R34a R404A R507 R22 R407C R40A Working Pressure [ C] R34a R404A R507 R22 R407C R40A PS [bar] DCB 082 / 082s DCB 083 / 083s DCB 084 / 084s DCB DCB 63 / 63s DCB 64 / 64s DCB 65 / 65s DCB DCB 304 / 304s DCB 305 / 305s DCB 307s ) Drying capacity is based on following moisture content test standards before and after drying: R34a: ppm W R404A, R507: ppm W R407C: ppm W R40A: ppm W R22: ppm W In accordance with ARI ) Given in accordance with ARI for t e= -5 C t c= 30 C Δp = 0.07 bar For technical data on other refrigerants, please contact your Danfoss Sales Representative Ordering DMB flare Conn. Multi pack [in.] [mm] Qty. Code no. DMB Z42 DMB Z4 DMB Z40 DMB Z46 DMB Z45 DMB Z44 DMB Z43 DMB Z49 DMB Z48 DMB Z47 Danfoss 23Z8403 DCB flare Conn. Multi pack [in.] [mm] Qty. Code no. DCB Z402 DCB Z40 DCB Z400 DCB Z406 DCB Z405 DCB Z404 DCB Z403 DCB Z409 DCB Z408 DCB Z407 Danfoss DCS (za) DKRCC.PD.ED0.D H098 3

4 Ordering (continued) DMB Solder (cu-plated steel connectors) Conn. Multi pack Industrial pack Conn. Multi pack [in.] Qty. Code no. Qty. Code no. [mm] Qty. Code no. DMB 082s Z Z46 DMB 083s Z Z Z459 DMB 084s Z Z Z457 DMB 63s Z Z Z455 DMB 64s Z Z Z453 DMB 65s Z Z674 DMB 303s Z48 DMB 304s Z Z45 DMB 305s Z Z487 DMB 307s Z Z498 DMB 309s Z493 DCB Solder (cu-plated steel connectors) Conn. Multi pack Industrial pack Conn. Multi pack [in.] Qty. Code no. Qty. Code no. [mm] Qty. Code no. DCB 082s Z464 DCB 083s Z Z458 DCB 084s Z462 DCB 63s Z467 DCB 64s Z Z Z452 DCB 65s Z Z665 DCB 304s Z470 DCB 305s Z469 DCB 307s Z468 Danfoss DCS (za) DKRCC.PD.ED0.D H098 4

5 Identification codes Codes Description Filter drier D Drier Solid core Application B Bi-flow Filter housing volume (approx.) Connection (filter connection in 8 of an inch increments) Connection type C M 08 8 in in in. 3 80% Molecular Sieve / 20% activated alumina 00% Molecular Sieve core 2 4 in. / 6 mm in. / 0 mm 4 2 in. / 2 mm in. / 6 mm in. / 22 mm 9 8 in. (blank) s Solder connection (cu-plated steel connector) Example for type codes D M B 6 4 s Filter drier Solid core Application Size (volume) Connection (filter connection in 8 of an inch increments) Connection type Construction / flow direction Danfoss DCS (za) DKRCC.PD.ED0.D H098 5

6 Selection selection is made considering the application Refrigerant and oil types DCB DMB HFO Recommended Recommended Refrigerant HC ) Recommended Recommended HFC Recommended Recommended HCFC Recommended Recommended Mineral or AB Recommended Recommended Oil POE or PAG, pure Recommended Recommended POE or PAG, with additives Not recommended 2 ) Recommended ) Only solder versions (cu-plated / pure copper) and connection sizes below 25 mm are approved for flammable refrigerants now 2 ) DCB Hermetic filter driers contain activated alumina, which is a polar material used for acid adsorption. Many oil additives are also polar substances and can be adsorbed by the activated alumina, rendering them useless, and reducing the drier s acid capacity, though this is not harmful to the system Selection example Select the appropriate type (DMB or DCB) based on refrigerant and oil type. Then select the drier size based on the adsorption and liquid capacity required. a. Amount of charge: 5 kg R34a at tl = 24 C To dry 5 kg R34a at 24 C from 050 to 60 ppm moisture, a DMB 6 is necessary b. Cooling capacity: Qe = 25 kw To obtain a mass flow corresponding to 25 kw cooling capacity with a DMB 6 filter drier, a 2 inch connection must be chosen. Larger connections can be chosen in accordance with the liquid line dimension c. Result DMB 64 or DMB 65 can be used If the initial moisture content is very small or a planned change of the filter drier is considered, a smaller filter drier size can be chosen. Drying capacity [kg] refrigerant ) Liquid capacity [kw] 2 ) Max. R34a R404A R507 R22 R407C R40A Working Pressure [ C] R34a R404A R507 R22 R407C R40A PS [bar] DMB 082/082s DMB 083/083s DMB 084/084s DMB DMB 63/63s DMB 64/64s DMB 65/65s DMB DMB 304/304s DMB 305/305s DMB 307s Danfoss DCS (za) DKRCC.PD.ED0.D H098 6

7 Dimensions and weights s A L D D 2 Net weight [mm] [mm] [mm] [mm] [Kg] DMB/DCB DMB/DCB DMB/DCB DMB/DCB DMB/DCB DMB/DCB DMB/DCB DMB/DCB DMB/DCB DMB/DCB Solder connection (cu-plated steel connectors) A B L D D 2 Net weight [mm] [mm] [mm] [mm] [mm] [Kg] DMB/DCB 082s DMB/DCB 083s DMB/DCB 084s DMB/DCB 63s DMB/DCB 64s DMB/DCB 65s DMB/DCB 304s DMB/DCB 305s DMB/DCB 307s DMB 309s Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss DCS (za) DKRCC.PD.ED0.D H098 7

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB Data sheet ELIMINATOR Hermetic bi-flow filter drier s DMB and DCB Hermetic bi-flow filter driers, types DMB and DCB are for use in liquid lines on heat pumps. Hermetic bi-flow filter driers have built-in

More information

ELIMINATOR Hermetic filter drier Types DML and DCL

ELIMINATOR Hermetic filter drier Types DML and DCL Data sheet ELIMINATOR Hermetic filter drier s DML and DCL All ELIMINATOR driers have a solid core with binding material held to an absolute minimum. There are two types of ELIMINATOR cores. DML driers

More information

ELIMINATOR Hermetic filter drier Types DCL and DML

ELIMINATOR Hermetic filter drier Types DCL and DML Data sheet ELIMINATOR Hermetic filter drier s DCL and DML All ELIMINATOR driers have a solid core with binding material held to an absolute minimum. There are two types of ELIMINATOR cores. DML driers

More information

ELIMINATOR Hermetic filter drier Types DML and DCL

ELIMINATOR Hermetic filter drier Types DML and DCL MAKING MODERN LIVING POSSIBLE Data sheet ELIMINATOR Hermetic filter drier Types DML and DCL All ELIMINATOR driers have a solid core with binding material held to an absolute minimum. There are two types

More information

Eliminator Liquid line filter driers, type DCL and DML

Eliminator Liquid line filter driers, type DCL and DML Eliminator Liquid line filter driers, type DCL and DML Flare connection Solder connection (copper) REFRIGERATION AND AIR CONDITIONING Technical leaflet Eliminator Liquid line filter driers, type DCL and

More information

MAKING MODERN LIVING POSSIBLE. Eliminator Liquid line filter driers, DCL and DML. Flare connection. Solder connection (copper) Technical brochure

MAKING MODERN LIVING POSSIBLE. Eliminator Liquid line filter driers, DCL and DML. Flare connection. Solder connection (copper) Technical brochure MAKING MODERN LIVING POSSIBLE Eliminator Liquid line filter driers, DCL and DML Flare connection Solder connection (copper) Technical brochure Contents Page Introduction........................................................................................

More information

Crankcase pressure regulator Type KVL

Crankcase pressure regulator Type KVL Data sheet Crankcase pressure regulator KVL Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. KVL protects the compressor motor against overload during start-up

More information

Crankcase pressure regulator Type KVL

Crankcase pressure regulator Type KVL Data sheet Crankcase KVL KVL crankcase are used to protect the compressor motor against overload experienced during startup after long off periods or just after defrost periods. They are installed in the

More information

Technical brochure Eliminator filter drier DCR - with replaceable solid core

Technical brochure Eliminator filter drier DCR - with replaceable solid core MAKING MODERN LIVING POSSIBLE Technical brochure Eliminator filter drier DCR - with replaceable solid core www.danfoss.com Contents Page Introduction...3 Features...3 Approvals...3 Technical data...4 of

More information

Replaceable solid cores filter driers type CSR

Replaceable solid cores filter driers type CSR Replaceable solid cores filter driers type CSR N of cores Nominal volume [cm 3 ] (in 3 ) DIMENSIONS AND TECHNICAL CHARACTERISTICS Filtering surface ODS Ø [in.] [mm] ØD1 ØD2 H1 P E H K CSR485 5/8" 16 148

More information

HANDBOOK REFRIGERATING SYSTEM PROTECTORS. Ed REFRIGERATING SYSTEM PROTECTORS DP-ED 01/ ENG 1

HANDBOOK REFRIGERATING SYSTEM PROTECTORS. Ed REFRIGERATING SYSTEM PROTECTORS DP-ED 01/ ENG 1 HANDBOOK Ed. 2017 DP-ED 01/2017 - ENG 1 CHAPTER 3 Hermetic filter driers CERTIFIED BY UNDERWRITERS LABORATORIES INC. For refrigeration plants that use HCFC, HFC or HFO refrigerants APPLICATIONS The filters

More information

ADK Filter Drier. Alco Controls. Filter Drier. Features

ADK Filter Drier. Alco Controls. Filter Drier. Features ADK is a hermetic filter-drier with internal solid block for use on liquid line. Features Solid block Hermetic design Rugged steel shells Corrosion resistant epoxy paint Solder connection made from copper

More information

FDB Filter Drier. Alco Controls. FDB Filter Drier. Features. Introduction. Moisture removal capability. Construction

FDB Filter Drier. Alco Controls. FDB Filter Drier. Features. Introduction. Moisture removal capability. Construction ALCO FDB is a hermetic filter-drier in compacted bead style for use on liquid line. Features Compacted bead style (spring loaded) Hermetic design Rugged steel shells Corrosion resistant epoxy paint Solder

More information

FDB Filter Drier. FDB Filter Drier. Technical Data

FDB Filter Drier. FDB Filter Drier. Technical Data Technical Data ALCO FDB is a hermetic filter-drier in compacted bead style for use on liquid line. Features Compacted bead style (spring loaded) Hermetic design Rugged steel shells Cushioned flow for non-turbulent

More information

Crankcase pressure regulator Type KVL

Crankcase pressure regulator Type KVL MAKING MODERN LIVING POSSIBLE Data sheet Crankcase pressure regulator KVL Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. KVL protects the compressor motor

More information

BFK Bi-flow Filter Drier

BFK Bi-flow Filter Drier ALCO is a hermetic Bi-flow filter-drier in solid block style for use on liquid line in reversible refrigeration systems such as heat pump units. Features Solid block style Integrated check valves insure

More information

Uni-Flow Filter Driers

Uni-Flow Filter Driers STNDRD Uni-Flow Driers The filter driers of series DTG are used in refrigeration system with unidirectional flow to absorb moisture and acid in the system and to filter out the impurities. FETURES HIGH

More information

DCY. Anti-acid filter driers Refrigeration & Climate Components Solutions. n Applications

DCY. Anti-acid filter driers Refrigeration & Climate Components Solutions. n Applications 1.12 n Applications Filtering and drying of refrigerants and acid neutralization for liquid lines of refrigerating and air conditioning installations. n Functional features Products are compatible with

More information

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory) MAKING MODERN LIVING POSSIBLE Data sheet Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory) A CPCE hot gas bypass regulator is used to adapt compressor capacity to actual evaporator

More information

REFRIGERANT RECOVERY PRODUCTS

REFRIGERANT RECOVERY PRODUCTS REFRIGERANT RECOVERY PRODUCTS PARKER REFRIGERANT RECOVERY PRODUCT Parker provides a large selection of components for recovery, recycle and reclaim machines, protecting them from the many types of contaminants

More information

HANDBOOK PIPING ACCESSORIES. Ed PIPING ACCESSORIES AT-ED 01/ ENG 1

HANDBOOK PIPING ACCESSORIES. Ed PIPING ACCESSORIES AT-ED 01/ ENG 1 HANDBOOK Ed. 2017 AT-ED 01/2017 - ENG 1 CHAPTER 3 ACCESS FITTINGS AND VALVE CORES FOR REFRIGERATION PLANTS THAT USE HCFC, HFC, HC, HFO, OR R744 REFRIGERANTS APPLICATIONS The access fittings illustrated

More information

FILTER DRIERS PART NUMBER SIGNIFICANCE LIQUID LINE FILTER DRIERS TOTALINE LIQUID LINE FILTER DRIER PHYSICAL DATA DIMENSIONS

FILTER DRIERS PART NUMBER SIGNIFICANCE LIQUID LINE FILTER DRIERS TOTALINE LIQUID LINE FILTER DRIER PHYSICAL DATA DIMENSIONS TOTALINE LIQUID LINE FILTER DRIERS P502-8 SERIES P PART NUMBER SIGNIFICANCE P353 FEATURES Compacted bead filter drier Universal Replacement CFC, HCFC, HFC refrigerants Filtration first for more effective

More information

June 2015 / BULLETIN Catch-All. Liquid & Suction Line Filter-Driers FILTER-DRIERS. It s the CORE that counts!

June 2015 / BULLETIN Catch-All. Liquid & Suction Line Filter-Driers FILTER-DRIERS. It s the CORE that counts! June 2015 / BULLETIN 40-10 Catch-All Liquid & Suction Line Filter-Driers FILTER-DRIERS It s the CORE that counts! Page 2 Bulletin 40-10 Table of Contents The Sporlan Catch-All Liquid and Suction Line Filter-Driers

More information

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1 HANDBOOK Ed. 2017 RP-ED 01/2017 - ENG 1 CHAPTER 2 CRANKCASE PRESSURE REGULATORS For refrigeration plants that use HCFC or HFC refrigerants shutter continues to open, until the stroke limit is reached and

More information

Anti-acid filter driers DCY

Anti-acid filter driers DCY 1.1 n Applications Filtering and drying of refrigerants and acid neutralization for liquid lines of refrigerating and air conditioning installations. n Functional features o Products are compatible with

More information

FILTER DRIERS - SPORLAN

FILTER DRIERS - SPORLAN FILTER DRIERS - SPORLAN The universal acceptance of the Catch-All Filter-Drier is due to its unique moulded porous core, consisting of a blend of highly effective desiccants. The quality features built

More information

PRODUCT DATA DTG SERIES Unidirectional Filter Driers

PRODUCT DATA DTG SERIES Unidirectional Filter Driers The series DTG unidirectional filter-driers are used to protect air conditioning and refrigeration systems from moisture and contamination. FEATURES HIGHLY EFFICIENT IN MOISTURE AND CONTAMINATION REMOVAL

More information

Sight glass (High pressure) Type SGP X, SGP I, SGP N, SGP RX, SGP RI and SGP RN

Sight glass (High pressure) Type SGP X, SGP I, SGP N, SGP RX, SGP RI and SGP RN Sight glass (igh pressure) SGP X, SGP I, SGP N, SGP RX, SGP RI and SGP RN SGP are sight glasses for high pressure applications (Max. Working Pressure 52 bar / 754 psig). SGP is available with flare, solder

More information

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1 HANDBOOK Ed. 2017 1 CHAPTER 5 NORMALLY-CLOSED FOR REFRIGERATION PLANTS THAT USE HC REFRIGERANTS APPLICATION The solenoid valves illustrated in this chapter have been developed by Castel for all those refrigeration

More information

R-22 R-404A/R-502/R-507A R-12/

R-22 R-404A/R-502/R-507A R-12/ EMERSON CLIMATE TECHNOLOGIES-System Protectors Recommended System Tonnage Take-Apart Liquid Line Filter Driers in Tons* Description, Low Temp. & Commercial Installations Air Conditioning Field Replacement

More information

Parker TEV Model Visual

Parker TEV Model Visual PARKER - THERMOSTATIC EXPANSION VALVES TXV MODEL NUMBER SELECTION Parker TEV Model Visual N Series TEV C(E) Series TEV SC(E) Series TEV Applications: Applications: Applications: Low Profile Coolers, Rail

More information

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1 HANDBOOK Ed. 2017 VS-ED 01/2017 - ENG 1 CHAPTER 3 NORMALLY-CLOSED PULSE FOR REFRIGERATION PLANTS THAT USE HFC OR HFO REFRIGERANTS APPLICATION The solenoid valves illustrated in this chapter are designed

More information

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1 HANDBOOK Ed. 2017 VS-ED 01/2017 - ENG 1 2 VS-ED 01/2017 - ENG TABLE OF CONTENTS CHAPTER 1 CHAPTER 2 CHAPTER 3 CHAPTER 4 CHAPTER 5 CHAPTER 6 CHAPTER 7 CHAPTER 8 CHAPTER 9 CHAPTER 10 CHAPTER 11 CHAPTER 12

More information

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1 HANDBOOK Ed. 2017 1 CHAPTER 1 WITH SCREW SHUTTER FOR REFRIGERATION PLANTS THAT USE HCFC, HFC OR HFO REFRIGERANTS APPLICATIONS All valves illustrated in this chapter are designed for installation on commercial

More information

Thermostatic Expansion Valve

Thermostatic Expansion Valve STANDARD Thermostatic Expansion Valve RFKH series thermostatic expansion valves are used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant s superheat at the outlet

More information

Maneurop reciprocating compressors MT - MTZ - NTZ

Maneurop reciprocating compressors MT - MTZ - NTZ MAKING MODERN LIVING POSSIBLE Quick reference Maneurop reciprocating compressors MT - MTZ - NTZ 60 Hz - R404A - R507A - R407C - R134a - R22 - R417A www.cc.danfoss.com Quick reference Dimensions Ø D ø

More information

Reliable season change

Reliable season change New perspectives with Danfoss Saginomiya 4 - Way Reversing Valves Reliable season change, VHV 4-way reversing valves Wide application range - complete capacity range - available for all common refrigerants

More information

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8 Electrical Control s Series EX4, EX5, EX6, EX7 & EX8 Features Multifunction as expansion valve, hot gas bypass, suction gas throttling, head pressure, liquid level actuator etc. Fully hermetic design (no

More information

ON/OFF zone valves AMZ 112, AMZ 113

ON/OFF zone valves AMZ 112, AMZ 113 Data sheet ON/OFF zone valves AMZ 112, AMZ 113 Description The ON/OFF zone valves type AMZ 112 and AMZ 113 are typical used in connection with: Domestic and commercial central heating applications Domestic

More information

TAKE-A-PART SHELLS TOTALINE LIQUID & SUCTION LINE REPLACEABLE SHELLS P505-8 SERIES PART NUMBER SIGNIFICANCE

TAKE-A-PART SHELLS TOTALINE LIQUID & SUCTION LINE REPLACEABLE SHELLS P505-8 SERIES PART NUMBER SIGNIFICANCE TOTALINE LIQUID & SUCTION LINE REPLACEABLE SHELLS P505-8 SERIES P PART NUMBER SIGNIFICANCE P360 SIZE (in 1/8 ) 505-8 TOTALINE FILTER DRIER SHELLS APPLICATION Totaline Replaceable Core Shells offer the

More information

Crankcase Pressure Regulating Valves

Crankcase Pressure Regulating Valves Crankcase Regulating Valves Crankcase Regulating Valves are designed to prevent overloading of the compressor motor by limiting the crankcase pressure to a predetermined maximum value during and after

More information

Technical brochure Electrically operated expansion valves, type ETS 6

Technical brochure Electrically operated expansion valves, type ETS 6 MAKING MODERN LIVING POSSIBLE Technical brochure Electrically operated expansion valves, type ETS 6 With many years of experience the current range of Electronic Expansion Valves offers high reliability

More information

Refrigeration K-211. Replacement Parts. Chillers, Condensers. Compressors, Motors. Electrical. Components. Heating. Indoor Air Quality.

Refrigeration K-211. Replacement Parts. Chillers, Condensers. Compressors, Motors. Electrical. Components. Heating. Indoor Air Quality. EMERSON CLIMATE TECHNOLOGIES-Oil Controls High Efficiency Centrifugal Oil Separator The High Efficiency Centrifugal Oil Separator is used in ultra-low temperature systems with long refrigerant lines or

More information

REFRIGERANTS AND LUBRICANTS

REFRIGERANTS AND LUBRICANTS Service Engineers Section Bulletin No 10 REFRIGERANTS AND 1.0 INTRODUCTION - THE NEED FOR IN REFRIGERATION SYSTEMS Lubricants (oils) are required in refrigeration systems to: Reduce friction by interposing

More information

The precise step to take

The precise step to take New perspectives with Danfoss Saginomiya Electronic Expansion Valves The precise step to take Type KV Electronic Expansion Valves Energy efficiency Precision flow control with high resolution Compact and

More information

Filter solutions for Danfoss PAH, APP and CLP pumps

Filter solutions for Danfoss PAH, APP and CLP pumps MAKING MODERN LIVING POSSIBLE Technical data sheet Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Filter solutions for Danfoss PAH, APP and CLP pumps 521B1009 / dkcfn.pd.090.a4.02

More information

Pressure operated water valve Type WVFX and WVS

Pressure operated water valve Type WVFX and WVS Data sheet Pressure operated water valve WVFX and WVS Pressure operated water valves types WVFX and WVS are used for regulating the flow of water in refrigeration plants with water-cooled condensers. The

More information

Danfoss Saginomiya 4 - Way Reversing Valves

Danfoss Saginomiya 4 - Way Reversing Valves New perspectives with anfoss Saginomiya - Way Reversing Valves Reliable season change ST, VHV -way reversing valves Wide application range - complete capacity range - available for all common refrigerants

More information

Performer scroll compressors. SM - SY - SZ R407C - R134a - R22-50 Hz QUICK REFERENCE MAKING MODERN LIVING POSSIBLE

Performer scroll compressors. SM - SY - SZ R407C - R134a - R22-50 Hz QUICK REFERENCE MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Performer scroll compressors SM - SY - SZ R407C - R134a - R22-50 z REFRIGERATION & AIR CONDITIONING DIVISION QUICK REFERENCE PRODUCT RANGE SINGLE COMPRESSORS 0 D ØD Ø D ØD

More information

AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT

AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT SANHUA Strive for perfection, Pursuit of excellence Sanhua is a leading HVAC&R manufacturer of controls and components with a global

More information

MAKING MODERN LIVING POSSIBLE. Performer scroll compressors. SM - SY - SZ R407C - R134a - R22-50 Hz. Quick reference

MAKING MODERN LIVING POSSIBLE. Performer scroll compressors. SM - SY - SZ R407C - R134a - R22-50 Hz. Quick reference MAKING MODERN LIVING POSSIBLE Performer scroll compressors SM - SY - SZ R407C - R134a - R22-50 z Quick reference PRODUCT RANGE SINGLE COMPRESSORS Ø D Ø D 0 D 2 2 2 1 1 1 D 1 2 S084-090-100 254 508 142

More information

Pressure Control Type KPU

Pressure Control Type KPU MAKING MODERN LIVING POSSIBLE Data sheet Pressure Control Type KPU KPU controls are designed for use in refrigeration and air-conditioning systems to protect the systems from excessively low suction or

More information

Thermostatic expansion valves Type TGE 10, TGE 20 and TGE 40

Thermostatic expansion valves Type TGE 10, TGE 20 and TGE 40 MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic expansion valves Type TGE 10, TGE 20 and TGE 40 TGE is a dedicated designed series of thermostatic expansion valves for all standard refrigerants including

More information

Electric expansion valves Type ETS 6

Electric expansion valves Type ETS 6 MAKING MODERN LIVING POSSIBLE Data sheet Electric expansion valves Type ETS 6 The range of Electric expansion valves are based on many years of experience. ETS 6 secure reliability and provide a precise

More information

Subcritical CO 2 Innovations

Subcritical CO 2 Innovations March 2011 / CATALOG 744 Subcritical CO 2 Innovations Energy Conscious Products & Solutions for Supermarkets Subcritical CO 2 Innovations Energy Conscious Products & Solutions for Supermarkets CATALOG

More information

Solenoid valves Type EVU for fluorinated refrigerants

Solenoid valves Type EVU for fluorinated refrigerants Data sheet Solenoid valves EVU for fluorinated refrigerants EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied

More information

WEIGHT (lb) PART NO WITH ACCESS CONNECTION (ODS) BALL PORT DIAMETER WA WAS

WEIGHT (lb) PART NO WITH ACCESS CONNECTION (ODS) BALL PORT DIAMETER WA WAS SUPERIOR - BALL VALVES WA SERIES (WELDED) WAS Series (Welded with Access Fittings) Full Service Temperature Range of -40 F to +325 F. Forged Brass Body and Seal Cap. Design Working Pressure: 700 psig.

More information

Electrical Control Valves

Electrical Control Valves 172 Electrical Control Valves Electrical Control Valves Electrical Control Valve Technology Thermostatic expansion valves and mechanical regulator valves have been used in the refrigeration and air conditioning

More information

The Danfoss Turbocor Portfolio of Oil Free Compressors

The Danfoss Turbocor Portfolio of Oil Free Compressors Fact Sheet Models TT, TG, and VTT The Danfoss Turbocor Portfolio of Oil Free Compressors Highly efficient compressors that reduce OEMs operating and maintenance costs Capacity range from 140 to 1400 kw

More information

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1 HANDBOOK Ed. 2017 1 2 INDEX CHAPTER 1 CHAPTER 2 CHAPTER 3 CHAPTER 4 CHAPTER 5 CHAPTER 6 CHAPTER 7 CHAPTER 8 CHAPTER 9 CHAPTER 10 CHAPTER 11 CHAPTER 12 CHAPTER 13 CHAPTER 14 Valves with screw shutter For

More information

Reliable season change

Reliable season change ew perspectives with anfoss Saginomiya 4 - Way Reversing Valves Reliable season change ST, VHV 4-way reversing valves Wide application range - complete capacity range - available for all common refrigerants

More information

A full line of field-tested CO 2 controls, stocked for your convenience

A full line of field-tested CO 2 controls, stocked for your convenience A full line of field-tested controls, stocked for your convenience 7000+ systems built with products www.danfoss.us/aftermarket Why choose for? has pioneered technologies for both transcritical and subcritical

More information

EMERSON CLIMATE TECHNOLOGIES

EMERSON CLIMATE TECHNOLOGIES STAS STEEL TAKE-APART FILTER DRIER APPLICATION Replaceable core filter-drier for CFC, HCFC and HFC refrigerants for use in large commercial air conditioning and refrigeration systems. FEATURES Unique internal

More information

HANDBOOK EXPANSION VALVES. Ed EXPANSION VALVES VE-ED 01/ ENG 1

HANDBOOK EXPANSION VALVES. Ed EXPANSION VALVES VE-ED 01/ ENG 1 HANDBOOK Ed. 2017 VE-ED 01/2017 - ENG 1 CHAPTER 12 STEP-MOTOR CERTIFIED BY UNDERWRITERS LABORATORIES INC. FOR REFRIGERATION PLANTS THAT USE HCFC, HFC OR HFO REFRIGERANTS belonging to Group 2, as defined

More information

Flow-compensated temperature controller AVTQ DN 15

Flow-compensated temperature controller AVTQ DN 15 Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers

More information

Capacity regulators (hot gas bypass) PMC and CVC

Capacity regulators (hot gas bypass) PMC and CVC MAKING MODERN LIVING POSSIBLE Technical brochure Capacity regulators (hot gas bypass) PMC and CVC The PMC and CVC is used for capacity regulation in refrigeration, freezing and air conditioning plant for

More information

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING. MAKING MODERN LIVING POSSIBLE Solenoid valves EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical

More information

MAKING MODERN LIVING POSSIBLE. Residential and light commercial scroll compressors R407C - R22 - R410A 60 HZ QUICK REFERENCE

MAKING MODERN LIVING POSSIBLE. Residential and light commercial scroll compressors R407C - R22 - R410A 60 HZ QUICK REFERENCE MAKING MODERN LIVING POSSIBLE Residential and light commercial scroll compressors R407C - R22 - R410A 60 HZ QUICK REFERENCE DIMENSIONS Ø 9.41 Ø 7.5 Ø 9.41 Ø 7.5 Ø 9.13 Ø 7.5 Ø 9.41 Ø 7.5 D D D D H2 H H2

More information

Control Card VLT FC Series

Control Card VLT FC Series These instructions describe the replacement of the control card in: VLT HVAC Drive FC 102. VLT Refrigeration Drive FC 103. VLT AQUA Drive FC 202. VLT AutomationDrive FC 301/FC 302. VLT Lift Drive LD 302.

More information

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: AMV 0 1)

More information

Alco Controls. Components for the Refrigeration Industry. Product Selection Catalogue

Alco Controls. Components for the Refrigeration Industry. Product Selection Catalogue Alco Controls Components for the Refrigeration Industry Product Selection Catalogue Note: The components listed in this catalogue are not released for use with caustic, poisonous or flammable substances.

More information

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive Installation Guide VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive FC 301/FC 302 Installation Guide VLT Real-time Clock MCB

More information

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure

More information

Modulating liquid level regulators, direct-controlled SV 1 and SV 3

Modulating liquid level regulators, direct-controlled SV 1 and SV 3 MAKING MODERN LIVING POSSIBLE Technical brochure Modulating liquid level regulators, direct-controlled SV 1 and SV 3 The SV 1 and 3 can be used separately as a modulating liquid level regulator in refrigerating,

More information

Electric expansion valve Type ETS ETS 400

Electric expansion valve Type ETS ETS 400 Data sheet Electric expansion valve Type ETS 12.5 - ETS 400 ETS is a series of electric expansion valves for precise liquid injection in evaporators for air conditioning and refrigeration applications.

More information

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS SOLENOID VALVES 17 SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive

More information

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows Application Integrated valves, type RA-N (013G0380) and RA- U (013G0381), with built-in presetting are designed for

More information

Electronic suction modulating valves type KVS

Electronic suction modulating valves type KVS MAKING MODERN LIVING POSSIBLE Technical brochure Electronic suction modulating valves type KVS KVS is a series of electronic suction modulating valves for AC transport and refrigeration applications. Accurate

More information

The new ICF 15-4 valve station: It s small, it s modular, it s flexible

The new ICF 15-4 valve station: It s small, it s modular, it s flexible The new ICF 15-4 valve station: It s small, it s modular, it s flexible Control your installation and servicing costs and be ready for all future refrigerants One compact platform 6 different valve configurations

More information

APP pump instruction APP and APP 16-22

APP pump instruction APP and APP 16-22 MAKING MODERN LIVING POSSIBLE Instruction APP pump instruction APP 11-13 and APP 16-22 www.ro-solutions.com Table of Contents 1. Identification...2 2. System design...3 2.1 Open-ended systems with direct

More information

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps Data sheet PAH pumps 2/4/6.3, PAH 10/12.5, PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and and PAH 50/63/70/80/100 PAH 50/63/70/80/100 pumps danfoss.high-pressurepumps.com hpp.danfoss.com Table of Contents

More information

Valve bodies type RA-N with integrated presetting

Valve bodies type RA-N with integrated presetting Data Sheet Application Straight version Angle version Left mounted angle version Horizontal angle version All RA-N valve bodies can be used together with all types of thermostatic elements in the RA 2000

More information

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically

More information

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically

More information

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet Solenoid valves EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 DKRCCPDBB0A202-520H275 Danfoss A/S, 0-2006 Contents Page Introduction.......................................................................................

More information

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application RA-N 013G7382 013G7387 Integrated valves, type RA-N 013G7382 and 013G7387, with built-in presetting are

More information

ICV with flanges: Danfoss now makes retrofit easy

ICV with flanges: Danfoss now makes retrofit easy ICV with flanges: Danfoss now makes retrofit easy Danfoss has upgraded the Industrial Refrigeration retrofit market with the introduction of our full replacement valve for all common flanged control valves

More information

Danfoss VDHT Solenoid Valves WATER SOLUTIONS

Danfoss VDHT Solenoid Valves WATER SOLUTIONS Danfoss VDHT Solenoid Valves danfoss HIGH-PRESSURE WATER SOLUTIONS What is a Danfoss VDHT valve? Facts and benefits The VDHT solenoid valve programme consists of both single valves and manifold block solutions

More information

SCY. Discharge line mufflers Refrigeration & Climate Components Solutions. n Applications

SCY. Discharge line mufflers Refrigeration & Climate Components Solutions. n Applications Refrigeration & limate omponents Solutions 21.1 TY-EN 21.1-6 / 02-2018 SY n Applications Reduction of noise caused by gas pulses in the discharge lines of refrigerating and air conditioning installations.

More information

XV7.2KX Variable Speed Drive Compressor R600a V 50/60Hz

XV7.2KX Variable Speed Drive Compressor R600a V 50/60Hz XV7.2KX Variable Speed Drive Compressor R600a 220-240V 50/60Hz General Code number Electronic unit (attached) - XV-AEO/Freq. Inputs: Modbus, thermostat, frequency signal Electronic unit (detached) - XV-Frequency

More information

Semi-hermetic reciprocating compressors

Semi-hermetic reciprocating compressors v9 FCAT00.6-EN Product Selection Catalogue Version Hz Catalogue index Index - General information General information Range of models Special features Technical specifications Multifunctional device Kriwan

More information

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems Data Sheet Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems The integrated valve is designed for manifold applications in combination with a system connection piece. Valve and

More information

Cartridge pressure switch Type CB

Cartridge pressure switch Type CB Data sheet Cartridge pressure switch Type CB Pressure controls CB series are compact disc type pressure switches with fixed set-points for long-standing use in refrigeration and air conditioning systems.

More information

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Solenoid valve VDHT Standard BSP (British Standard Pipe) MAKING MODERN LIVING POSSIBLE Data sheet Standard BSP (British Standard Pipe) high-pressurepumps.danfoss.com Contents 1. Picture overview...3 2. Introduction...4 3. VDHT valve selection overview...4 4.

More information

PAHT pumps / PAHT G pumps / ATEX PAHT G pump

PAHT pumps / PAHT G pumps / ATEX PAHT G pump Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Data sheet PAHT 2-308 pumps / PAHT G 2-308 pumps / ATEX PAHT G pump danfoss.high-pressurepumps.com Table of Contents

More information

Electric expansion valve Type ETS ETS 400

Electric expansion valve Type ETS ETS 400 MAKING MODERN LIVING POSSIBLE Data sheet Electric expansion valve Type ETS 12.5 - ETS 400 ETS is a series of electric expansion valves for precise liquid injection in evaporators for air conditioning and

More information

PAHT pump PAHT X

PAHT pump PAHT X MAKING MODERN LIVING POSSIBLE Data sheet PAHT pump PAHT X 674 444 danfoss.high-pressurepumps.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Application areas...3 4. Technical data...4 5.

More information

Product Guide for HFO / HFO Blends. R448A/R449A R450A/R513A R1234ze. R134a R407A/F R404A/507 R12/502

Product Guide for HFO / HFO Blends. R448A/R449A R450A/R513A R1234ze. R134a R407A/F R404A/507 R12/502 Product Guide 2016 for HFO / HFO Blends R448A/R449A R450A/R513A R1234ze R134a R407A/F R404A/507 R12/502 Preface Many end-users, equipment and compressor manufacturers are investigating ways to minimize

More information

X-tra Collection for designer radiators and bathroom towel rails

X-tra Collection for designer radiators and bathroom towel rails and bathroom towel rails Application The new X-tra Collection is a TRV specially designed for towel rails and designer radiators. Its new and innovative self-sealing ½" valve to radiator connection makes

More information

Pressure relief controller AVA (PN 25)

Pressure relief controller AVA (PN 25) Data sheet Pressure relief controller AVA (PN 25) Description AVA is a self-acting pressure relief controller primarily for use in district heating systems. The controller is normally closed and opens

More information