For ATEX zone 1/1, 22/22 and 21/21. Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h

Size: px
Start display at page:

Download "For ATEX zone 1/1, 22/22 and 21/21. Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h"

Transcription

1 For ATEX zone 1/1, 22/22 and 21/21 Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive or sticky fumes, dust and chips. Fan and spark retardant pre-ring are made according to norm EN Work area: Max. pressure: 5,8 Max. air volume: 32,5m³/h Max. dust volume: 5g/m³, non-sticky Max. particle size: 5x5x5mm, non-sticky Temperature: Extracted air (transport air in fan) = max. 6 C Ambient temperature: max. 4 C Construction: Radial fan with closed fan wheel mounted in fully welded steel cabinet and with directly coupled motor. Model: Wheel: C (Transport of dust) Fan wheel type P-G. Closed wheel with backward straight, self-cleaning blades Static/dynamically balanced according to ISO (BV3 G 6.3) Cabinet: Fully welded in 3 or 4mm steel plate Spark retardant pre-ring made in copper Fan housing can be mounted with various inlet positions (RD, RD45, RD9, RD135, RD27 and RD315) Standard enamelling: Standard delivered in galvanzied version. Subsequently powder enamelled (RAL 57). Motor: B3+B5 flange motor 3x4V, 5Hz (3-phased motors 3x4VAC can with special motor frequency regulated. Motor must be marked with frequency regulation data.) Motor zone 1: Motor zone 22: II 3D Ex - IIB T12 C Motor zone 21: II 2D Ex h IIIB T12 C II 2G Exe - IIC T3 / II 2G Exde IIC T4 Fan type RV-A-C is made especially for the selected ATEXzone and equipped with ATEX-certificate from factory. Constructed and tested according to: Machine Directive 26/42/EF ISO 581 ATEX-Directive 214/34/EU ISO 679-(+A11)-(1)-(7)-(14)-(15)-(31) EMC-Directive 214/3/EU ISO Low Voltage Directive 214/35/EU EN 6529+A1+A2 EN IEC 634-(1)-(2-1)-(5)-(6)-(7)-(8)-(9)-(12)-(14)-(3-1) EN 121 EN ISO EN ISO EN ISO ISO EN ISO 36 1.RVAC1

2 Type Order no. ATEX zone 1 1) Order no. ATEX zone 22 Order no. ATEX zone 21 1) RV-A 35/1-C RV-A 35/2-C RV-A 35/3-C RV-A 45-C RV-A 5-C RV-A 6-C RV-A 7-C RV-A 8-C RV-A 85-C RV-A 9-C RV-A 35-C RV-A 45-C RV-A 5-C RV-A 6-C RV-A 7-C RV-A 8-C RV-A 85-C RV-A 9-C ) DTI Ref. no A Type Volt [V] Pole [kw] Max. amp. Start current RV-A 35/1-C2 3x RV-A 35/2-C2 3x RV-A 35/3-C2 3x RV-A 45-C2 3x RV-A 5-C2 3x RV-A 6-C2 3x RV-A 7-C2 3x RV-A 8-C2 3x RV-A 85-C2 3x RV-A 9-C2 3x RV-A 35-C4 3x RV-A 45-C4 3x RV-A 5-C4 3x RV-A 6-C4 3x RV-A 7-C4 3x RV-A 8-C4 3x RV-A 85-C4 3x Weight [kg] RV-A 9-C4 3x RVAC2

3 Type A B C D E F G H I J K L RV-A 35/1-C ø25 ø RV-A 35/2-C ø25 ø RV-A 35/3-C ø25 ø RV-A 45-C ø315 ø RV-A 5-C ø4 ø RV-A 6-C ø5 ø RV-A 7-C ø63 ø RV-A 8-C ø8 ø RV-A 85-C ø8 ø RV-A 9-C ø8 ø RV-A 35-C ø25 ø RV-A 45-C ø315 ø RV-A 5-C ø4 ø RV-A 6-C ø5 ø RV-A 7-C ø63 ø RV-A 8-C ø8 ø RV-A 85-C ø8 ø RV-A 9-C ø8 ø Please, note: Connection measurements are nipple measurements 1.RVAC3

4 7 Fan RV 35-1-C Noise fan (Laeq ) Total efficiency () 71 7, m³/h 7 79 Fan RV 35-2-C Noise fan ( ) Total efficiency () 73 72, m³/h Fan RV 35-3-C2 7, 73, m³/h Noise fan ( ) Total efficiency () 1.RVAC4

5 Fan RV 45-C2 7,, m³/h Noise fan ( ) Total efficiency () Fan RV 5-C2 84 8, , , m³/h Noise fan ( ) Total efficiency () Fan RV 6-C2 7, 75, m³/h Noise fan ( ) Total efficiency () 1.RVAC5

6 Fan RV 7-C2 9 7, , m³/h Noise fan ( ) Total efficiency () Fan RV 8-C2 84, , 8, 7, m³/h Noise fan (Laeq ) Total efficiency () RV 85-C2 8, 7, 84, m³/h Noise fan (Laeq ) Total efficiency () 1.RVAC6

7 Fan RV 9-C2 8, 7, 85, m³/h Noise fan (Laeq ) Total efficiency () Fan RV 35-C , m³/h Noise fan ( ) Total efficiency () Fan RV 45-C m³/h 1.RVAC7

8 Fan RV 5-C4 6, m³/h Noise fan ( ) Total efficiency () Fan RV 6-C4 7 7, , m³/h Noise fan ( ) Total efficiency () Fan RV 7-C4 7, 62, m³/h Noise fan ( ) Total efficiency () 1.RVAC8

9 Fan RV 8-C4 8, 7, 64, m³/h Noise fan ( ) Total efficiency () Fan RV 85-C4 8, 7, Noise fan ( ) 7 Total efficiency () , m³/h Fan RV 9-C4 7, 67, m³/h Noise fan ( ) Total efficiency () 1.RVAC9

10 EQUIPMENT Sound enclosure type VB/VAB-A*: Type (Position RD) Order no. RV-A 35/ RV-A 35/ RV-A 35/ RV-A RV-A 45, zone RV-A RV-A 5, zone RV-A RV-A RV-A 7, zone RV-A RV-A RV-A * Only for clean air transport Fan wheels: Type Hub [mm] Fan type** [Hz] Order no. RV 35/1 ø28 C RV 35/2 ø28 C RV 35/3 ø28 C RV 45 ø38 C RV 5 ø38 C RV 6 ø42 C RV 7 ø48 C RV 8 ø55 C RV 85 ø55 C RV 9 ø55 C RV 35 ø19 C RV 5 ø24 C RV 6 ø28 C RV 7 ø28 C RV 8 ø28 C RV 85 ø38 C RV 9 ø38 C **Closed Transport Futher is available: Pressure guard in ATEX-version Mounting fittings Vibrations absorbers Safety grid FLEX flexible connections Photo: ABB frequency converter type ACH 58 - Do not forget application of ATEX-approved thermister relay - see price list 1.RVAC1

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page

Work area: Max. pressure: 2,150Pa Max. air volume: 2.100m³/h. Manufacturer. Production year. Model number/type. page Centrifugal fan with closed fan wheel that is used at source extraction from air pollulant or chip making work processes. The transported air may not contain adhestive or sticky fumes or dust. Work area:

More information

LEF/MEF LEX/MEX ATEX versions

LEF/MEF LEX/MEX ATEX versions Fan LEF/MEF 250-630 - LEX/MEX ATEX versions GEOVENT centrifugal fan LEX and MEX with closed backward curving B-wheel and directly driven flange motor. The fan is used for extraction within the industry

More information

Small centrifugal fans made of plastic

Small centrifugal fans made of plastic Small centrifugal fans made of plastic durable application-optimised wide range of variants 2 Small centrifugal fans made of plastic Index Small centrifugal fans made of plastic HF R 75-16 D and HF R 110-18

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

Explosion and flame-proof single phase electric motors

Explosion and flame-proof single phase electric motors Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz Types of mounting

More information

Explosion and flame-proof cast iron electric motors

Explosion and flame-proof cast iron electric motors Explosion and flame-proof cast iron electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 160 3 phases Voltage 230/400 V 50Hz Voltage 265/460V 60Hz Types of mounting

More information

AXIAL FANS Catalogue CN0050C01 May 2008

AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 ADTA AXIAL FANS Catalogue CN0050C01 May 2008 Construction Specifications Impellers: Breezax aerfoil blades are available in four types of material: Glass Reinforced

More information

AXIAL FLOW CABINET FAN CGT Series

AXIAL FLOW CABINET FAN CGT Series Range of adjustable pitch aerofoil blade, axial flow cabinet fans. Fan casing manufactured from heavy gauge galvanised sheet steel internally lined with 25 mm thickness fireproof fibreglass acoustic insulation

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS - ADJUSTABLE PITCH FANS Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dip galvanised finish. All models incorporate

More information

PAB Atex-certified centrifugal pumps

PAB Atex-certified centrifugal pumps 1 6036 EN PAB Atex-certified centrifugal pumps Technical data Delivery rate Q max = 305 l/min Delivery head H max = 20 m Temperature range 0 C to +60 C Quality Management DIN EN ISO 9001: 2008 Environmental

More information

CYLINDRICAL CASED AXIAL FLOW FANS

CYLINDRICAL CASED AXIAL FLOW FANS - Adjustable pitch fans Range of adjustable pitch aerofoil blade, cased axial flow fans. Casings formed from rolled sheet steel with a corrosion resistant hot dipped galvanised finish. All models incorporate

More information

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: AAVC HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES: Accessories Fan made of Fe360 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved at 200ºC, with an average

More information

Centrifugal fan with highly efficient EC drive motor

Centrifugal fan with highly efficient EC drive motor Centrifugal fan with highly efficient EC drive motor simple and safe application and installation 2 Why HLU? 90 years of experience in the plastics processing market More than 10.000 m² production in Germany

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

I Ex-safety switches I

I Ex-safety switches I EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX

More information

NCF fans 60Hz. Protection class IP 55

NCF fans 60Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

Flameproof brake motors. Technical data subject to change without notice. BARTEC VARNOST 1

Flameproof brake motors. Technical data subject to change without notice. BARTEC VARNOST 1 Flameproof brake motors Technical data subject to change without notice. BARTEC VARNOST 1 2 BARTEC VARNOST Technical data subject to change without notice. Flameproof brake motors 4KTC - General performance

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

10 Load and Motor Switchgear

10 Load and Motor Switchgear 10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,

More information

EX-REPAIR AND MAINTENANCE RECEPTACLES

EX-REPAIR AND MAINTENANCE RECEPTACLES EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand

More information

VORTICENT C E RANGE Centrifugal fans

VORTICENT C E RANGE Centrifugal fans NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,

More information

Floodlight Series 6121

Floodlight Series 6121 www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options

More information

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C BACKWARD CURVED CENTRIFUGAL FANS CMRT Series 80 C Continuous operation Range of single inlet direct drive centrifugal fans designed for continuous extraction of air stream up to 80ºC. Casings are manufactured

More information

Motors and drives for applications in explosive atmospheres

Motors and drives for applications in explosive atmospheres Motors and drives for applications in explosive atmospheres Certification. Diligence. Reliability. Safety. Everything counts Operating processes in explosive (Ex) atmospheres requires the right mix of

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

Centrifugal medium-pressure fans fitted with multi-blade

Centrifugal medium-pressure fans fitted with multi-blade CMP/ATEX CMP/ATEX impeller Centrifugal medium-pressure fans fitted with multi-blade with ATEX certification Centrifugal single-inlet, medium-pressure fans with casing and sheet steel impeller to work in

More information

Panelboards & Motor Starters

Panelboards & Motor Starters Appleton s ATX series of Increased Safety distribution panels are available in IP66-rated fiberglass reinforced polyester (FRP) or 316L stainless steel and come in multiple sizes depending on the number

More information

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard, RADIAL CENTRIFUGAL FANS CBT-N Series CONTINUO Range of single inlet direct driven centrifugal fans designed for the continuous extraction of air stream up to 120ºC(1). The casings are manufactured from

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

MTB /183 A-F-A-BQQV 400D-2 11kW

MTB /183 A-F-A-BQQV 400D-2 11kW GRUNDFOS DATA BOOKLET MTB 65-2/13 A-F-A-BQQV D-2 11kW Grundfos Pump 965751 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/mtb/965751/mtb-65-2-13-a-f-a-bqqv.html

More information

NCF 60 Hz. Protection class IP 55

NCF 60 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

FEATURES & BENEFITS UPON REQUEST

FEATURES & BENEFITS UPON REQUEST ErP 27 IDUSTRIAL CETRIFUGAL FAS WITH VERY HIGH PRESSURE APPLICATIO High pressure industrial centrifugal fans with backward curved impeller, suitable for exhausting clean or slightly dusty air. They can

More information

CGT Series Adjustable Pitch Fans

CGT Series Adjustable Pitch Fans AXIAL FLOW CABINET FAN CGT Series Adjustable Pitch Fans New Ø 400-450-500 Range of adjustable pitch aerofoil blade, axial flow cabinet fans.fan casing manufactured from heavy gauge galvanised sheet steel

More information

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information. In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V

More information

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety ATX PRE Series 125 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator

More information

V. Aa. Gram A/S

V. Aa. Gram A/S Compact compressed-air cleaned filter unit with timer control for filtration of welding smoke, grinding dust, cutting smoke and dusty air containing metal, rock, plastic etc. or from handling various powder

More information

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and

More information

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence Explosion proof fans General Systemair explosion proof fans have been developed to be used in effective supply and exhaust air systems allocated to category 2 (zone 1) and category 3 (zone 2) in explosion

More information

NCF fans 50 Hz. Protection class IP 55

NCF fans 50 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL

More information

K: bracket type. L: pole type

K: bracket type. L: pole type Lighting Technology Catalogue number logic B0091-0 -0 0 0 Pendant Light Fittings BDD91 Series Explosion-proof Light Fittings Explosion protection to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2

More information

PRE Series 125 Amp Plugs and Sockets Increased Safety

PRE Series 125 Amp Plugs and Sockets Increased Safety s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 125 Amp s and Sockets - IK10 Applications s and sockets are used with stationary or portable electrically operated devices

More information

V. Aa. Gram A/S

V. Aa. Gram A/S Energy-optimized unit for larger filtration tasks. Is used for filtration of welding smoke, grinding dust, cutting smoke and dusty air containing metal, rocks, plastic etc. or from handling various powder

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless

More information

Section 4. Axial Fans - Section 4

Section 4. Axial Fans - Section 4 Axial Flow Fans Section 4 Fläkt Woods offers a wide range of axial flow fans for general air movement and special applications such as emergency high temperature smoke extract and pressurisation. ATEX

More information

F a n t y p e s J K K - J K K

F a n t y p e s J K K - J K K F a n t y p e s J K - 3 K - J K - 7 5 K Section: 2 Page: 1/6 Revised: 1..25 The indirect drive centrifugal fan types JK-3K - JK-75K are designed for material handling. M N Equipped with self-cleaning impellers

More information

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES Ex d IIB+H 2 ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES ALUMINIUM ENCLOSURES STAINLESS STEEL ENCLOSURES EJB... series enclosures offer Ex d IIB +H 2 mode of protection. These enclosures are

More information

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de

More information

AATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES:

AATVP. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES: AATVP HIGH PRESSURE WITH BACKWARD IMPELLER AND BELT TRASMISSION MANUFACTURING FEATURES: Accessories Fan made of Fe36 sheet. The fan paint finish is based on a Qualicoat polyester powder coating stoved

More information

Oil/air cooler BLK ATEX-3GD

Oil/air cooler BLK ATEX-3GD FluidControl Oil/air cooler BLK ATEX-3GD Drives and hydraulic aggregates are also used in explosive areas in machine construction or raw material production. In hydraulic systems oil transfers power and

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22 Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation

More information

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13 Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.

More information

Short casing. Long casing (L version) Commercial premises

Short casing. Long casing (L version) Commercial premises CYLINDRICAL CASED AXIAL FLOW FANS TGT Series Adjustable Pitch Fans Long casing (L version) Short casing A P P L I C A T I O N S Range of adjustable pitch cased axial flow fans. Casings formed from rolled

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced CENTRIFUGAL SINGLE INLET FANS CMB / CMT Series 80 C CONTINUOUS operation Range of centrifugal single inlet fans suitable for continuous extraction of airstreams temperature up to 80ºC (Series 1) or 150ºC

More information

MTB /158 A-F-A-BQQV 400D-2 5,5kW

MTB /158 A-F-A-BQQV 400D-2 5,5kW GRUNDFOS DATA BOOKLET MTB 5-1/158 A-F-A-BQQV D- 5,5kW Grundfos pump 95879 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/mtb/95879/mtb-5-1-158-a-f-a-bqqv.html

More information

Motors for hazardous areas New cast iron motors in sizes

Motors for hazardous areas New cast iron motors in sizes Motors for hazardous areas New cast iron motors in sizes 160-180 Cast iron motors for hazardous areas New design for sizes 160 to 180 With the new product platform for hazardous area motors ABB is now

More information

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1. xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof

More information

Safety Switches Series 8537

Safety Switches Series 8537 Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part

More information

List Price. Mult. Sym. C Dim. Single Phase

List Price. Mult. Sym. C Dim. Single Phase Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru 300 48 thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group

More information

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru 300 48 thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder

More information

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A .1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility

More information

Control and Terminal Box Type A21-**-*****

Control and Terminal Box Type A21-**-***** e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de

More information

ATX DPD Series Distribution Panelboards Flameproof

ATX DPD Series Distribution Panelboards Flameproof ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation

More information

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22 Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance

More information

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety ATX PRE Series 63 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator

More information

COMPACT Series type HCFB / HCFT (Plastic impellers)

COMPACT Series type HCFB / HCFT (Plastic impellers) Plate mounted axial flow fans COMPACT HCFB/HCFT PLATE MOUNTED AXIAL FLOW FANS COMPACT Series type HCFB / HCFT (Plastic impellers) 0 017582 603079 Compact design Corrosion resistance Flame retardant terminal

More information

MZ, MA. Liquid ring pumps. 3 Design. 1 Fields of application. 4 Designation. 5 Materials. 2 Operating Data

MZ, MA. Liquid ring pumps. 3 Design. 1 Fields of application. 4 Designation. 5 Materials. 2 Operating Data Type series booklet CTI-1700/00 [12-2008] MZ, MA Liquid ring pumps 1 Fields of application Multi-stage, horizontal liquid ring pumps, with self-priming capacity. MZ and MA pumps are used for pumping of

More information

NB /193 A-F2-A-BAQE

NB /193 A-F2-A-BAQE GRUNDFOS DATA BOOKLET NB100-200/193 A-F2-A-BAQE Grundfos Pump 98305367 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/nb000/98305367/nb-100-200-193-a-f2-a-e-baqe.html

More information

11 Control Panels, Distribution Panels and Components

11 Control Panels, Distribution Panels and Components Control Panels, Distribution Panels and Components Motor Switches Explosion protection to CENELEC IEC For use in Zone and Zone Isolator Motor switching capacity Rated working voltage up to Rated working

More information

Sheet-Steel Light Fittings Series 6014 / 6414

Sheet-Steel Light Fittings Series 6014 / 6414 > As 1-, 2-, 3- or 4-lamp version > Versions pendant light fittngs wall-mounting s recessed s > Powder-coated sheet-steel or stainless steel > Central lock > All-pole disconnection via NC switch in positive

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

Terminal Boxes Series 8252/1

Terminal Boxes Series 8252/1 www.stahl.de > Ex d enclosure made of saltwater-resistant, copper-free aluminium cast alloy > Powder coated to RAL 7032 > Available in 3 different sizes > With DIN rail for standard terminals > Enclosure

More information

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge CENTRIFLOW 3D plug fan WITH AC MOTOR >> Technical catalouge air comfort Centriflow 3D 2 GMEB CentriFlow 3D - Technical Catalouge Contents GENERAL Description and survey chart Application... 3 General Survey

More information

CRE32-3 AN-F-A-E-HQQE 3x HZ

CRE32-3 AN-F-A-E-HQQE 3x HZ GRUNDFOS DATA BOOKLET CRE32-3 AN-F-A-E-HQQE 3x4 5 HZ Grundfos Pump 96122652 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/cre32/96122652/cre-32-3-an-f-a-e-hqqe.html

More information

High voltage flameproof induction motors The simplest solution for hazardous environments

High voltage flameproof induction motors The simplest solution for hazardous environments High voltage flameproof induction motors The simplest solution for hazardous environments We offer motors and generators, services and expertise that save energy and improve our customers processes over

More information

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities 3-35 kw 10,200-119,420 Btuh 208 to 600 Volts 1 or 3 Phase Meets NEC, OSHA and UL Requirements ATEX and GOST Models Available Refer to WR-80EP in the Controls section. F-4 Description Type is designed to

More information

CRE A-F-A-E-HQQE 3x HZ

CRE A-F-A-E-HQQE 3x HZ GRUNDFOS DATA BOOKLET CRE45-2-2 A-F-A-E-HQQE 3x4 5 HZ Grundfos Pump 96123388 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/cre45/96123388/cre-45-2-2-a-f-a-e-hqqe.html

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

CHMT Series, F Rated Fans

CHMT Series, F Rated Fans CNTRIFUGAL SINGL INLT FANS CT Series, F400 120 Rated Fans Officially approved to N12101-3 standard (certificate number 0370-CPD-0348) Range of single inlet direct drive centrifugal fans designed for smoke

More information

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22 WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge

More information

Load disconnect switch Series 8146/5-V11

Load disconnect switch Series 8146/5-V11 www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation

More information

REVOLUTION SLCX Product Brochure

REVOLUTION SLCX Product Brochure REVOLUTION SLCX Brochure Available for next day delivery with ELTA SELECT ATEX Long Cased Axial Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum

More information

RWCP, RWCN. Vertical pumps for tanks for loaded liquids. 1. Fields of Application. 3. Design. 4. Designation. 2. Operating Data

RWCP, RWCN. Vertical pumps for tanks for loaded liquids. 1. Fields of Application. 3. Design. 4. Designation. 2. Operating Data Type series booklet CTI-4900/01 [04-2012] RWCP, RWCN Vertical pumps for tanks for loaded liquids 1. Fields of Application RWCP and RWCN are vertical, centrifugal pumps designed for wells, ditches and tanks.

More information

PRE Series 63 Amp Plugs and Sockets Increased Safety

PRE Series 63 Amp Plugs and Sockets Increased Safety Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator sets Air conditionings Compressors

More information

: B3; B5; B14; B34; B35; V1

: B3; B5; B14; B34; B35; V1 ATT WE series (Eff1) are 3-phase TEFC Cast-Iron high efficiency general purpose induction motors, which are designed to meet or exceed the requirements for energy efficiency such as: European Eff1, Australia

More information

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L Lighting Technology BAY- x Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC Can be used in Zone and Zone One or two lamp version; Available lamp wattage:

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

THREE-PHASE SQUIRREL-CAGE INDUCTION MOTORS EXPLOSION-PROOF FRAME

THREE-PHASE SQUIRREL-CAGE INDUCTION MOTORS EXPLOSION-PROOF FRAME MASZYNY ELEKTRYCZNE CELMA SA ISO 9001: 2000 ISO 14001 THREE-PHASE SQUIRREL-CAGE INDUCTION MOTORS EXPLOSION-PROOF FRAME 80 132 Type: ECS(K,L,1)g, ECS(K,L,1)gb CS(K,L,1)g, CS(K,L,1)gb GENERAL INFORMATION

More information