MODELS S4LX, S4BX, S4KX, S4QX, H4QX, S4LVX, S6AX, S6LX and S8FX

Size: px
Start display at page:

Download "MODELS S4LX, S4BX, S4KX, S4QX, H4QX, S4LVX, S6AX, S6LX and S8FX"

Transcription

1 SLX MODELS SLX, SBX, SKX, SQX, HQX, SLVX, SAX, SLX and SFX (Class I, Division, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE PUMP INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. SLX SFX Item # E-0- Part # -- 0 Pentair Pump Group, Inc. //

2 Thank you for purchasing your Hydromatic pump. To help ensure years of trouble-free op er a tion, please read the following manual carefully. Before Operation: Read the following in structions care ful ly. Reasonable care and safe meth ods should be practiced. Check local codes and requirements before installation. Attention: This manual contains important information for the safe use of this product. Read this manual completely before using this product and refer to it often for con tin ued safe product use. DO NOT THROW AWAY OR LOSE THIS MANUAL. Keep it in a safe place so that you may refer to it often. Unpacking Pump: Remove pump from carton. When un pack ing unit, check for con cealed damage. Claims for damage must be made at the receiving end through the delivery carrier. Dam age cannot be processed from the factory. WARNING: Before handling these pumps and controls, always disconnect the power first. Do not smoke or use sparkable electrical devices or flames in a septic (gaseous) or possible septic sump. General Information CALIFORNIA PROPOSITION WARNING: This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Pumps in Storage or Not Operating: Pumps with carbon ceramic seals must have impellers manually rotated ( revolutions) after setting non-operational for months or longer and prior to electrical start-up. Pumps with tungsten carbide seals must have impellers manually rotated ( revolutions) after setting non-operational for weeks or longer and prior to electrical start-up. Seal Failure Probes: All hazardous location submersible pumps have two factory installed mois ture detectors (seal failure probes). They are in a normally open series cir cuit, in the seal chamber. Un der normal operating conditions, the circuit remains open. If the lower seal leaks and moisture enters this cham ber, the moisture would settle to the bottom of the chamber and will com plete the circuit between the moisture detectors. This circuit must be connected to a sensing unit and signaling device. This is supplied in a Hydromatic built control panel. NOTE: Failure to install such a device negates all war ran ties by Hydromatic. Heat Sensors: All motors in this family have heat sensors on or embedded in the motor winding to detect ex ces sive heat. This prevents damage to the motor. If sen sor trips due to excessive winding tem per a ture, starter in panel breaks power to the pump. Once sensor re sets, the starter is automatically reset for FM for continued operation of the pump. This circuitry is supplied in a Hydromatic control panel. NOTE: Failure to install such circuitry negates FM ap prov als and all warranties by Hydromatic. Power Cords: The power cord and heat sensor seal failure cord are potted into the con nec tion box cap. The cords must not be spliced. NOTE: Each cable has a green lead. This is the ground wire and must be grounded properly per NEC and/or local codes. Cords should be in spect ed for abnormal wear and replaced accordingly. Overload Heaters: If the Hydromatic electrical panel is not used, start ers with leg overload relay must be supplied on phase pumps. Each leg is to have an iden ti cal heater sized in accordance with the nameplate amps on the motor hous ing. The amp draws on these sub mers ible motors is slightly higher than a cor re spond ing horsepower sur face motor, so heat ers must be sized by the nameplate rating.

3 Pump Installation Installing Sump Level Control Float Controls: In either simplex, duplex or triplex systems the lower or turn-off control is to be set to Installing Sump Level Control Float Controls: In either simplex, duplex or triplex systems the lower or turn-off control is to be set to maintain a minimum level in the sump. This level shall be no more than " from the top of the motor housing down to the surface of the sewage. The second or turn-on control is set above the lower turn-off control. The exact distance between the two floats must be a compromise between a fre quent pumping cycle ( starts per hour max.) to control septicity, solids and a slower cycle for energy econ o my. This distance should be de ter mined by the engineer or consulting engineer depending on the con di tions of the application. For installation of Hydromatic supplied level con trols refer to your sys tem s installation and service manual. Installing Pump in Sump: Before installing pump in sump lay it on side and rotate impeller. Impeller may be slightly stuck due to factory test water so it must be broken loose with small bar or screwdriver in edge of vanes. The impeller should turn freely. Do not connect the power until after this test. Clean all trash and sticks from sump and connect pump to piping. A check valve must be installed on each pump. A gate or plug valve in each pump discharge is highly rec om mend ed. This valve should be installed on the discharge side of the check valve so if necessary to service the check valve the line pressure can be cut off. Sin gle pump systems are sometimes installed without a check valve where it is de sir able to self-drain the dis charge line to prevent freezing. This can be done only with short discharge lines; oth er wise water will return to the sump and cause short cycling of the pump. Making Electrical Connections: All electrical wiring must be in ac cor dance with local code, and only qual i fied electricians should make the in stal la tions. All wires should be checked for shorts to ground with an ohmmeter or Megger after the con nec tions are made. This is important, as one grounded wire can cause considerable trouble. IMPORTANT: If equipment is not properly wired and protected as recommended, Hydromatic warran ty is void. Heat Sensor and Seal Failure Connections: If a Hydromatic control panel is used, terminal blocks are provided for heat sensor, seal failure connections. If a control panel is supplied by others, it must allow heat sensor and seal failure terminations. Pump Operations Starting System:. Double check all wire connections.. Turn pumps to Off position on H-O-A switch es.. Turn on breakers.. Turn H-O-A switch to Hand po si tion on one pump and notice oper ation. If pump is noisy and vibrates, rotation is wrong. To change ro ta tion, interchange any two line leads to pump. Do not in terchange main incoming lines. Check ro ta tion of all pumps in this same man ner.. Now set both H-O-A switches to Auto po si tion and allow water to rise in sump until one pump starts. Allow pump to operate until the level drops to turn-off point.. Allow sump level to rise to start other pump(s). Notice run lights to panel. Pumps should alternate on each successive cycle of operation.. Turn both H-O-A switches to Off position and allow sump to fill to the override control level(s).. Turn switches to Auto position, and pumps should start and op er ate together until level drops to turn-off point.. Repeat this operation cycle sev er al times before leaving the job.

4 . Check voltage when pumps are operating, and check the amp draw of each pump. Check amps on each wire as sometimes a high leg will exist. One leg can be some what higher by to per cent without causing trouble. For excessive amp draw on one leg, the electric utility company should be consulted. Pump Maintenance As the motors are oil filled, no lubrication or other main te nance is required. If the heat sensor and seal failure are hooked up properly, no attention is necessary as long as the seal failure indicator light doesn t come on. To ensure continuity of the seal sensor leads, a test light is provided on in trin si cal ly safe Hydromatic panels as standard equipment. Pump should be checked every quar ter for cor ro sion and wear. Field Service on Hydromatic Hazardous Location Pumps: If a Hydromatic hazardous location pump is used in a hazardous location, or if the pump is still in war ran ty, the pump must be returned to the factory for service or repaired at an authorized Hydromatic service center. Charges will not be allowed if in war ran ty pump is not taken to an authorized Hydromatic service cen ter. This will ensure the integrity of the hazardous location rating of the pump and com ply with our warranty requirements. Disconnecting Pump Cords: If a Hydromatic hazardous location pump is to be removed from its lo ca tion, the pump cords may be disconnected at control panel (on sump mounted con trol panels) and cord as sem bly taken with pump. CAUTION: If cord openings from sump to con trol panel are open, gas es from sump could enter panel and an explosive condition could ex ist. CAUTION: Do not reconnect pow er to a cord and cap assembly while removing from pump. Replacing Cords: The power cord and heat sensor - seal failure cord is potted into the con nec tion box cap, forming the cord and cap assembly. If cords require replacement due to damage or cords being too short, cord and cap assembly must be replaced as a complete assembly avail able from factory. Check pump for proper rotation before re turn ing to normal service. Replacing Lower Seal, Impeller or Volute: The wet end components may be repaired or replaced by an authorized Hydromatic service facility without compromising the hazardous location rating to the pump. NOTE: Any time the seal is disturbed, it must be replaced.

5 SLX Parts List RTF Cord Cap Assy Connector -/- HP 00//0 RPM -/- HP 0/0//0 RPM -/- HP //0 RPM - HP 00//0 RPM - HP 0/0//0 RPM - HP //0 RPM HP 0//0 RPM -0 HP 0//0 RPM -/- HP 00//0 RPM -/- HP 0/0//0 RPM -0 HP //0 RPM Connector -0 HP 0//0 RPM Connector -0 HP 00//0 RPM -0 HP 0/0//0 RPM -0 HP 0//0 RPM 0 HP 0//0 RPM Connector 0 HP 0//0 RPM Connector -/- HP 0//0 RPM - HP 0//0 RPM Connector -/- HP 0//0 RPM - HP 0//0 RPM Connector HP 0//0 RPM -0 HP 0//0 RPM O-Ring SC Connector Connector -/- HP 00//0 RPM -/- HP //0 RPM - HP 00//0 RPM - HP //0 RPM -/- HP 0/0//0 RPM - HP 0/0//0 RPM Connector -0 HP 00//0 RPM -0 HP 0//0 RPM Connector -0 HP 0/0//0 RPM Connector -0 HP 0//0 RPM Connector - HP 00//0 RPM -/- HP 00//0 RPM HP //0 RPM -0 HP //0 RPM -0 HP 0/0//0 RPM Key Stator Holding Ring Lower Bearing O-Ring SC Seal Sensor Assy Seal Failure Terminal Pipe Plug Key O-Ring Capscrew Roll Pin Seal Plate 0-0- Impeller." dia 0-0- Impeller." dia Impeller.00" dia Impeller." dia Impeller.0" dia 0-0- Impeller." dia 0-0- Impeller.00" dia 0-0- Impeller." dia Impeller.0" dia 0-0- Impeller.00" dia Impeller." dia 0-0- Impeller." dia Impeller." dia O-Ring SC Impeller Washer Capscrew Wearing Ring Lower Seal, Ceramic (std) S Lower Seal, Carbide (opt) C Volute Capscrew Retaining Ring Bearing Housing Upper Seal SC Capscrew Shaft Sleeve SC Capscrew RTF Stator RTF Rotor & Shaft Motor Housing HP 0 RPM, -0 HP 0 RPM -00- Motor Housing -/- HP 0 RPM, - HP 0 RPM Screen Fill Oil to above the Top of Motor Windings, Spacer -/- HP 0 RPM Spacer -0 HP 0 RPM Spacer -- HP 0 RPM 0A0 Upper Bearing Load Spring Jam Nut Eye Bolt Connection Box #- -/- HP 00//0 RPM -/- HP //0 RPM -/- HP 00//0 RPM -/- HP //0 RPM -0 HP //0 RPM Connection Box #- -/- HP 0/0//0 RPM - HP 0/0//0 RPM Connection Box #- -0 HP 00//0 RPM -0 HP 0//0 RPM Connection Box #- -0 HP 0/0//0 RPM Connection Box #- -0 HP 0//0 RPM O-Ring SC Capscrew SST Capscrew SST Setscrew Labyrinth Ring Seal Kit 00-- Carbide Seal Kit 0 0

6 SFX Parts List RTF Cord Assy, Dual Connector HP 00/0/0///0 RPM HP 0/0///0 RPM 0 HP 0/0//0 RPM -/ HP 00/0/0//0 RPM 0 HP // Connector HP 00/0/0//0 RPM -0 HP 0//0 RPM Connector 0 HP 00/0/0//0 RPM 0 HP 0//0 RPM 0 HP 0//0 RPM Connector 0 HP 0//0 RPM Connector HP 0//0 RPM HP 0//0 RPM Connector -/ HP 0//0 RPM HP 0//0 RPM Connector HP 0//0 RPM 0 HP 0//0 RPM O-Ring SC Connector Connector HP //0 RPM HP 00//0 RPM HP //0 RPM HP 0/0//0 RPM HP 0/0//0 RPM Connector 0 HP 00//0 RPM 0 HP 0//0 RPM 0 HP //0 Connector 0 HP 0/0//0 RPM Connector 0 HP 0//0 RPM Connector HP 00//0 RPM -/ HP 00//0 RPM HP //0 RPM 0 HP //0 RPM Connector 0 HP 0//0 RPM Key Stator Holding Ring Lower Bearing O-Ring SC Seal Sensor Assy Seal Failure Terminal Pipe Plug Safety Wire O-Ring SC Capscrew Key Seal Plate 0-0- Impeller." Impeller." Impeller.0" Impeller." 0-0- Impeller." Impeller." 0-0- Impeller." Impeller.0" 0-0- Impeller." Impeller.", Impeller.0" Roll Pin Impeller Washer Capscrew Wearing Ring Lower Seal (Std.) S Lower Seal (Carbide) C Volute w/ring 0A0 Capscrew Retaining Ring Bearing Housing Upper Seal SC Capscrew Shaft Sleeve SC Capscrew RTF Stator RTF Rotor & Shaft Motor Housing HP 0 RPM 0 HP 0 RPM -00- HP 0 RPM HP 0 RPM 0A00 O-Ring SC Spacer HP 0 RPM HP 0 RPM HP 0 RPM 0A0 Upper Bearing Bearing Adj. Spring 0 DUAL VOLTAGE PHASE MOTOR WIRING 0V ø 0V ø BL W R (L) (L) (L) BL W R (L) (L) (L) Nut Bolt Connection Box #- HP 00//0 RPM HP //0 RPM HP 00//0 RPM HP //0 RPM 0 HP //0 RPM Connection Box #- - HP 0/0//0 RPM - HP 0/0//0 RPM Connection Box #- 0 HP 00//0 RPM 0 HP 0//0 RPM Connection Box #- 0 HP 0/0//0 RPM Connection Box #- 0 HP 0//0 RPM O-Ring SC A0 Capscrew, SS A0 Capscrew, SS Screen Setscrew Labryrinth Ring Seal Kit 00-- Carbide Seal Kit Fill Oil to above the Top of the Motor Windings

7 SBX Parts List RTF Cord Cap Assy Connector & HP 00, 0/0, //0 RPM Connector & HP 0/0//0 RPM Connector. & HP 00//0 RPM Connector,.,, HP 00 & //0 RPM Connector HP 00, 0/0//0 RPM Connector,., HP 0/0//0 RPM Connector, HP 0/0//0 RPM Connector 0 HP 00, 0/0//0 RPM Connector -0 HP 0 & 0//0 RPM Connector -0 HP 0 & //0 RPM Connector 0,, 0 HP //0 RPM Connector 0 HP 0//0 RPM Connector 0 HP 0/0//0 RPM O-Ring SC Connector Connector,., HP //0 RPM HP 00//0 RPM & HP //0 RPM Connector,., HP 0/0//0 RPM & HP 0/0//0 RPM Connector 0 HP 00//0 RPM 0, 0, 0 HP 0//0 RPM 0 & 0 HP //0 RPM Connector 0 HP 0/0//0 RPM Connector & 0 HP 00//0 RPM 0 & 0 HP 0//0 RPM HP 0//0 RPM Connector HP 0//0 RPM Connector 0,, 0 HP //0 RPM HP //0 RPM. & HP 00//0 RPM & HP 00//0 RPM -0 HP 0//0 RPM Connector -0 HP 0//0 RPM O-Ring SC Stator Holding Ring Lower Bearing O-Ring SC Seal Sensor Assy Seal Failure Terminal Pipe Plug Safety Wire Retaining Ring Capscrew Seal Plate -00- Impeller.00" dia 0, -00- Impeller.00" dia -00- Impeller.00" dia -0- Impeller.0" dia -0- Impeller.00" dia Impeller Washer Capscrew Wearing Ring Lower Seal, Ceramic (std) S Lower Seal, Carbide (opt) C -00- Volute Capscrew Bearing Housing Upper Seal SC Capscrew Capscrew RTF Stator RTF Shaft Sleeve SC Motor Housing HP 0 RPM, and All 0 RPM -00- Motor Housing, HP 0 RPM,,., HP 0 RPM Spacer 0 HP 0 RPM Spacer & HP 0 RPM Spacer & HP 0 RPM 0A0 Upper Bearing Load Spring Jam Nut Eye Bolt Connection Box #- 0, 0 DUAL VOLTAGE PHASE MOTOR WIRING 0V ø 0V ø BL W R (L) (L) (L) BL W R (L) (L) (L) 0-0 HP //0 RPM,.,, HP //0 RPM HP 00//0 RPM & HP 00///0 RPM Connection Box #-,., HP 0/0//0 RPM & HP 0/0//0 RPM Connection Box #- 0 HP 00//0 RPM 0 & 0 HP //0 RPM.,, Connection Box #- 0 HP 0/0//0 RPM -0 HP 0//0 RPM -0 HP 0//0 RPM Connection Box #- -0 HP 00//0 RPM 0 HP 0//0 RPM O-Ring SC Capscrew SST Capscrew SST Key Roll Pin Setscrew Labyrinth Ring Screen Seal Kit 00-- Carbide Seal Kit Fill Oil to above the Motor Windings

8 SKX Parts List Cord Cap Assy Connector 0 HP 0/0//0 RPM -0 HP 0//0 RPM 0-0 HP //0 RPM Connector -0 HP 00//0 RPM -0 HP 0//0 RPM Connector -0 HP 0//0 RPM Connector 0-0 HP 00//0 RPM 0 HP 0/0//0 RPM -0 HP 0//0 RPM 0 HP 0//0 RPM Connector 0 HP 00//0 RPM 0 HP 0//0 RPM O-Ring SC Connector Connector 0 HP 00//0 RPM -0 HP 0//0 RPM Connector 0 HP 0/0//0 RPM Connector -0 HP 00//0 RPM -0 HP 0//0 RPM Connector 0-0 HP //0 RPM O-Ring Stator Holding Ring Lower Bearing O-Ring SC Seal Sensor Assy Seal Failure Terminal Pipe Plug Safety Wire SC Retaining Ring Capscrew Shaft Sleeve SC Seal Plate 0-0- Impeller." dia Impeller.00" dia Impeller.0" dia Impeller.00" dia Roll Pin Impeller Washer Capscrew Wearing Ring Lower Seal, Ceramic (std) S Lower Seal, Carbide (opt) C Volute Capscrew Retaining Ring -00- Bearing Housing Upper Seal SC Capscrew Key Capscrew RTF Stator RTF Rotor & Shaft -00- Motor Housing -00- Screen Spacer 0 HP 0 RPM Upper Bearing Load Spring Jam Nut Eye Bolt Connection Box #- 0-0 HP //0 RPM Connection Box #- 0 HP 00//0 RPM Connection Box #- 0-0 HP 0/0//0 RPM 0 HP 00//0 RPM 0 HP 0//0 RPM Connection Box #- -0 HP 00//0 RPM 0 HP 0//0 RPM O-Ring SC CONNECTION DIAGRAM FOR LEADS IN MOTOR AND CONNECTION BOX (Y) WYE MOTOR CONNECTIONS 0 VOLTS 0 VOLTS L L L L L L Capscrew SST Capscrew SST Setscrew Labyrinth Ring Seal Kit 00-- Carbide Seal Kit 0, 0 0 Fill Oil to above the Motor Windings

9 SQX Parts List RTF Cord Cap Assy Connector, HP 0/0//0 RPM Connector 0 HP 00, 0/0//0 RPM Connector -0 HP 0 & 0//0 RPM Connector -0 HP 0 & //0 RPM Connector 0,, 0 HP //0 RPM Connector 0 HP 0/0//0 RPM O-Ring SC Connector Connector 0 HP 00//0 RPM 0, 0, 0 HP 0//0 RPM 0 & 0 HP //0 RPM Connector 0 HP 0/0//0 RPM Connector & 0 HP 00//0 RPM 0 & 0 HP 0//0 RPM HP 0//0 RPM Connector HP 0//0 RPM Connector 0,, 0 HP //0 RPM -0 HP 0//0 RPM Connector -0 HP 0//0 RPM 0A00 O-Ring SC Stator Holding Ring Lower Bearing O-Ring SC Seal Sensor Assy Seal Failure Terminal Pipe Plug Safety Wire Retaining Ring Capscrew Seal Plate -00- Impeller.00" dia -00- Impeller.0" dia -00- Impeller.00" dia -00- Impeller.0" dia -00- Impeller.00" dia -0- Impeller.0" dia -0- Impeller.00" dia Impeller Washer Capscrew Wearing Ring Lower Seal, Ceramic (std) S Lower Seal, Carbide (opt) C -00- Volute 0A0 Capscrew -00- Bearing Housing Upper Seal SC Capscrew Capscrew RTF Stator RTF Rotor & Shaft Motor Housing HP 0 RPM, and All 0 RPM Spacer 0 HP 0 RPM Upper Bearing Load Spring Jam Nut Eye Bolt Connection Box #- 0-0 HP //0 RPM Connection Box # Connection Box #- 0 HP 00//0 RPM 0 & 0 HP //0 RPM Connection Box #- 0 HP 0/0//0 RPM -0 HP 0//0 RPM Connection Box #- -0 HP 00//0 RPM O-Ring SC A0 Capscrew SST A0 Capscrew SST Key Roll Pin Fill Oil to above the Motor Windings 0, DUAL VOLTAGE PHASE MOTOR WIRING 0V ø 0V ø BL W R (L) (L) (L) BL W R (L) (L) (L) Setscrew Labyrinth Ring -00- Screen Shaft Sleeve Seal Kit 00-- Carbide Seal Kit Screw Adapter Wear Ring -00- Adapter Volute Gasket Retaining Ring 0, 0

10 HQX Parts List RTF Cord Cap Assy Connector 0 HP 0/0//0 RPM -0 HP 0//0 RPM 0-0 HP //0 RPM Connector -0 HP 00//0 RPM -0 HP 0//0 RPM Connector -0 HP 0//0 RPM Connector 0-0 HP 00//0 RPM 0 HP 0/0//0 RPM -0 HP 0//0 RPM 0 HP 0//0 RPM Connector 0 HP 00//0 RPM 0 HP 0//0 RPM O-Ring SC Connector Connector 0 HP 00//0 RPM -0 HP 0//0 RPM Connector 0 HP 0/0//0 RPM Connector -0 HP 00//0 RPM -0 HP 0//0 RPM Connector 0-0 HP //0 RPM O-Ring Stator Holding Ring Lower Bearing O-Ring SC Seal Sensor Assy Seal Failure Terminal Pipe Plug Safety Wire SC Retaining Ring Capscrew Shaft Sleeve Seal Plate -00- Impeller " dia Impeller.00" dia -00- Impeller " dia -00- Impeller.00" dia Key Impeller Washer Capscrew -00- Wearing Ring Lower Seal, Ceramic (std) S Lower Seal, Carbide (opt) C -00- Volute Capscrew Retaining Ring -00- Bearing Housing Upper Seal SC Capscrew Roll Pin Capscrew RTF Stator RTF Rotor & Shaft -00- Motor Housing -00- Screen Spacer 0 HP 0 RPM 0A0 Upper Bearing Load Spring Jam Nut Eye Bolt Connection Box #- 0-0 HP //0 RPM Connection Box #- 0 HP 00//0 RPM Connection Box #- 0-0 HP 0/0//0 RPM 0 HP 00//0 RPM 0 HP 0//0 RPM Connection Box #- -0 HP 00//0 RPM 0 HP 0//0 RPM O-Ring SC A0 Capscrew SST A0 Capscrew SST Setscrew Labyrinth Ring Seal Kit 00-- Carbide Seal Kit 0, 0 0 Fill Oil to above the Motor Windings

11 SLVX Parts List RTF Cord Assy, Connector HP 00//0 RPM HP 0/0//0 RPM HP //0 RPM HP 0/0//0 RPM HP //0 RPM 0 HP 0/0//0 -/ HP RPM -/ HP 0/0//0 RPM -0 HP // Connector 0 HP 0//0 RPM Connector 0 HP 00//0 RPM 0 0/0//0 RPM 0 HP 0//0 RPM 0 HP 0//0 RPM Connector 0 HP 0//0 RPM Connector HP 0/0//0 RPM HP 0/0//0 RPM Connector HP 0/0//0 RPM HP 0/0//0 RPM Connector 0 HP 0/0//0 RPM O-Ring SC Connector Connector HP 00//0 RPM HP //0 RPM HP 00//0RPM HP //0 RPM HP 0/0//0 RPM HP 0/0//0 RPM Connector 0 HP 00//0 RPM 0 HP 0//0 RPM 0 HP // Connector 0 HP 0/0//0 RPM Connector 0 HP 0//0 RPM Connector HP 00//0 RPM -/ HP 00//0 RPM HP //0 RPM 0 HP //0 RPM 0 HP 0//0 RPM Key Stator Holding Ring Lower Bearing O-Ring SC Seal Sensor Assy Seal Failure Probe Pipe Plug O-Ring SC O-Ring SC Capscrew Shaft Sleeve SC Seal Plate -0- Impeller." dia. 0, 0-0- Impeller." dia. -0- Impeller." dia. -0- Impeller." dia Impeller.00" dia. -0- Impeller." dia Impeller." dia Impeller.0" dia Impeller.00" dia Key Impeller Washer Capscrew Roll Pin Lower Seal (Std.) S Lower Seal (Carbide) C Volute Capscrews Retaining Ring Bearing Housing Upper Seal SC Capscrew Screen Capscrew RTF Stator RTF Rotor & Shaft Motor Housing HP 0 RPM 0 HP 0 RPM -00- Motor Housing HP 0 RPM HP 0 RPM Labyrinth Ring Spacer HP 0 RPM HP 0 RPM & HP 0 RPM 0A0 Upper Bearing Bearing Adj. Spring Nut Bolt Connection Box #- -/ HP 00//0 RPM -/ HP //0 RPM -/ HP 00//0 RPM -/ HP //0 RPM -0 HP //0 RPM Connection Box #- -/ HP 0/0//0 RPM HP 0/0//0 RPM Connection Box #- 0 HP 00//0 RPM 0 HP 0//0 RPM Connection Box #- 0 HP 0/0//0 RPM Connection Box #- -0 HP 0//0 RPM O-Ring SC Capscrew SST Capscrew SST Seal Kit 00-- Carbide Seal Kit 0 Fill Oil to above the Motor Windings

12 SAX Parts List RTF Cord Cap Assy Connector & HP 00, 0/0, //0 RPM & HP 0/0//0 RPM & HP 00//0 RPM ,, HP 00 & //0 RPM HP 00, 0/0//0 RPM , HP 0/0//0 RPM , HP 0 & 0//0 RPM HP 0 & //0 RPM & 0 HP //0 RPM HP 0//0 RPM O-Ring SC Connector Connector. & HP //0 RPM & HP //0 RPM Connector. & HP 0/0//0 RPM & HP 0/0//0 RPM Connector 0, 0, 0 HP 0//0 RPM 0 & 0 HP //0 RPM Connector Connector & 0 HP 00//0 RPM 0 & 0 HP 0//0 RPM HP 0//0 RPM Connector HP 0//0 RPM Connector & 0 HP //0 RPM HP //0 RPM. & HP 00//0 RPM & HP 00//0 RPM 0 HP 0//0 RPM Connector 0 HP 0//0 RPM O-Ring SC Stator Holding Ring Lower Bearing O-Ring SC Seal Sensor Assy Seal Failure Terminal Pipe Plug Shaft Sleeve SC Retaining Ring Capscrew Seal Plate -00- Impeller.00" dia -00- Impeller.0" dia -00- Impeller.00" dia -0- Impeller.0" dia -0- Impeller.00" dia Impeller Washer Capscrew Wearing Ring Lower Seal, Ceramic (std) S Lower Seal, Carbide (opt) C -00- Volute 0 0, Capscrew Bearing Housing Upper Seal SC Capscrew Capscrew RTF Stator RTF Rotor & Shaft Motor Housing HP 0 RPM, all 0 RPM -00- Motor Housing & HP 0 RPM,. & HP 0 RPM Spacer HP 0 RPM Spacer & HP 0 RPM Upper Bearing Load Spring Jam Nut Eye Bolt Connection Box #- 0 HP //0 RPM.,, HP //0 RPM & HP 00///0 RPM Connection Box #-., HP 0/0//0 RPM & HP 0/0//0 RPM 0, DUAL VOLTAGE PHASE MOTOR WIRING 0V ø 0V ø BL W R (L) (L) (L) BL W R (L) (L) (L) Connection Box #- 0 & 0 HP //0 RPM.,, Connection Box #- 0 HP 0//0 RPM 0 HP 0//0 RPM Connection Box #- 0 HP 00//0 RPM 0 HP 0//0 RPM O-Ring SC Capscrew SST Capscrew SST Drivescrew Roll Pin Setscrew Labyrinth Ring Screen Key Seal Kit 00-- Carbide Seal Kit Fill Oil to above the Motor Windings

13 SLX Parts List RTF Cord Assy, Connector HP 00/0/0///0 RPM HP 0/0//0 RPM HP //0 RPM HP 0//0 RPM 0 HP 0//0 -/ HP 00//0 RPM -/ HP 0/0//0 RPM 0 HP // HP 0//0 RPM Connector 0 HP 00//0 RPM 0 HP 0/0//0 RPM 0 HP 0//0 RPM 0 HP 0//0 RPM Connector 0 HP 0//0 RPM Connector -/ HP 0//0 RPM HP 0//0 RPM Connector -/ HP 0//0 RPM HP 0//0 RPM Connector HP 0//0 RPM 0 HP 0//0 RPM O-Ring SC Connector Connector -/ HP 00//0 RPM -/ HP //0 RPM HP 00//0 RPM HP //0 RPM -/ HP 0/0//0 RPM HP 0/0//0 RPM Connector 0 HP 00//0 RPM 0 HP 0//0 RPM 0 HP // Connector 0 HP 0/0//0 RPM Connector 0 HP 0//0 RPM Connector HP 00//0 RPM -/ 0 HP 00//0 RPM HP //0 RPM 0 HP //0 RPM 0 HP 0/0//0 RPM Key Stator Holding Ring Lower Bearing O-Ring SC Seal Sensor Assy Seal Failure Terminal Pipe Plug 0A00 O-Ring SC O-Ring SC Capscrew Shaft Sleeve SC Seal Plate Impeller." Impeller.0" 0-0- Impeller." Impeller." 0-0- Impeller." Impeller.0" 0-0- Impeller.00" Impeller." 0-0- Impeller.0" 0-0- Impeller." Key Impeller Washer Capscrew Wearing Ring Lower Seal (Std) S Lower Seal (Carbide) C Volute 0A0 Capscrew Retaining Ring Bearing Housing Upper Seal SC Capscrew Screen Capscrew RTF Stator RTF Rotor & Shaft Motor Housing HP 0 RPM 0 HP 0 RPM -00- HP 0 RPM HP 0 RPM Labyrinth Ring Spacer HP 0 RPM 0 CONNECTION DIAGRAM FOR LEADS IN MOTOR AND CONNECTION BOX (Y) WYE MOTOR CONNECTIONS 0 VOLTS 0 VOLTS L L L L L L Spacer 0 HP 0 RPM Spacer & HP 0 RPM 0A0 Upper Bearing Bearing Adjusting Spring Nut Bolt Connection Box #- HP 00///0 RPM HP 00//0 RPM HP //0 RPM 0 HP //0 RPM Connection Box #- HP 0/0//0 RPM HP 0/0//0 RPM Connection Box #- 0 HP 00//0 RPM 0 HP 0//0 RPM Connection Box #- 0 HP 0/0//0 RPM Connection Box #- 0 HP 0//0 RPM O-Ring SC A0 Capscrew SST A0 Capscrew SST Setscrew Seal Kit 00-- Carbide Seal Kit Fill Oil to above Top of the Motor Windings

14 THIS PAGE INTENTIONALLY LEFT BLANK

15 THIS PAGE INTENTIONALLY LEFT BLANK

16 STANDARD LIMITED WARRANTY Pentair Hydromatic warrants its products against defects in material and workmanship for a period of months from the date of shipment from Pentair Hydromatic or months from the manufacturing date, whichever occurs first provided that such products are used in compliance with the requirements of the Pentair Hydromatic catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids. During the warranty period and subject to the conditions set forth, Pentair Hydromatic, at its discretion, will repair or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Hydromatic reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for prior sold and/or shipped units. Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of start up through the Pentair Hydromatic website: Warranty is effective only if Pentair Hydromatic authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Pentair Hydromatic will cover only the lower seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Hydromatic be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Hydromatic service facility. This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Hydromatic or an authorized Pentair Hydromatic service provider; (h) to any unit that has been repaired using non factory specified/ OEM parts. Warranty Exclusions: Pentair HYDROMATIC MAKES NO EXPRESS OR IMPLIED WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. Pentair HYDROMATIC SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE. Liability Limitation: IN NO EVENT SHALL Pentair HYDROMATIC BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY Pentair HYDROMATIC PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER INSTALLATION. Pentair HYDROMATIC DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS WARRANTY, FOR IMPROPER INSTALLATION. Pentair HYDROMATIC RECOMMENDS INSTALLATION BY PROFESSIONALS. Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or consequential damages and therefore such limitations may not apply to you. No warranties or representations at any time made by any representatives of Pentair Hydromatic shall vary or expand the provision hereof. 0 EAST TH STREET 0 Pinebush Road, Unit # ASHLAND, OHIO, USA 0 CAMBRIDGE, ONTARIO, CANADA NT 0A PUMP Warranty Rev. /

(Class I, Division 1, Groups C & D): FM

(Class I, Division 1, Groups C & D): FM MODELS S4T(X)P, S8L(X)P, S8LA(X)P and S12L(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP INSTALLATION AND SERVICE MANUAL For use with product built with Premium Efficient

More information

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP MODEL HPGX200 (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the

More information

S4HVX Shown. (Class I, Division 1, Groups C & D): FM

S4HVX Shown. (Class I, Division 1, Groups C & D): FM S4HVX Shown H3HX Shown S4MX Shown MODELS H3HX, H4HX, S4MX, S4PX, S4HVX and S4MVX (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE PUMP INSTALLATION AND SERVICE MANUAL For use with

More information

(Class I, Division 1, Groups C & D): FM

(Class I, Division 1, Groups C & D): FM MODELS H4Q(X)P, S4K(X)P, S4L(X)P, S4LV(X)P, S4B(X)P, S6L(X)P, S6A(X)P and S8F(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP INSTALLATION AND SERVICE MANUAL For use with product

More information

MODELS: C4S(X)P, H3H(X)P, H4H(X)P, S4M(X)P, S4P(X)P, S4HV(X)P and S4MV(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP

MODELS: C4S(X)P, H3H(X)P, H4H(X)P, S4M(X)P, S4P(X)P, S4HV(X)P and S4MV(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP MODELS: C4S(X)P, H3H(X)P, H4H(X)P, S4M(X)P, S4P(X)P, S4HV(X)P and S4MV(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP INSTALLATION AND SERVICE MANUAL For use with product

More information

MODEL SPC-PANEL. Pump Controls for 2 HP Grinder Pumps

MODEL SPC-PANEL. Pump Controls for 2 HP Grinder Pumps MODEL SPC-PANEL Pump Controls for 2 HP Grinder Pumps SIMPLEX, SINGLE PHASE PUMP CONTROL PANEL INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner

More information

MODELS HPGFX/HPGHX & HPGFHX/HPGHHX

MODELS HPGFX/HPGHX & HPGFHX/HPGHHX HPGHX HPGFX MODELS HPGFX/HPGHX & HPGFHX/HPGHHX (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMPS INSTALLATION AND SERVICE MANUAL For use with product built with Regal

More information

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems. RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL Engineered for quick and easy replacement of existing progressive cavity grinder systems. Fully assembled Uses existing ball valve and latch Uses existing

More information

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP MODEL HPGX200 (Class I, Division, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner

More information

MODELS: C4S(X)P, H3H(X)P, H4H(X)P, S4M(X)P, S4P(X)P, S4HV(X)P and S4MV(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP

MODELS: C4S(X)P, H3H(X)P, H4H(X)P, S4M(X)P, S4P(X)P, S4HV(X)P and S4MV(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP MODELS: C4S(X)P, H3H(X)P, H4H(X)P, S4M(X)P, S4P(X)P, S4HV(X)P and S4MV(X)P (Class I, Division 1, Groups C & D): FM SUBMERSIBLE SOLIDS HANDLING PUMP INSTALLATION AND SERVICE MANUAL For use with product

More information

MODEL S4F SUBMERSIBLE SOLIDS HANDLING PUMP INSTALLATION AND SERVICE MANUAL

MODEL S4F SUBMERSIBLE SOLIDS HANDLING PUMP INSTALLATION AND SERVICE MANUAL MODEL S4F SUBMERSIBLE SOLIDS HANDLING PUMP INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who

More information

S3HVX Explosion-Proof Submersible Pump

S3HVX Explosion-Proof Submersible Pump Pump Installation and Service Manual S3HVX Explosion-Proof Submersible Pump (Class I, Division 1, Group D): UL (Class I, Division 1, Groups C & D): FM NOTE! To the installer: Please make sure you provide

More information

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS 471 US Hwy 250 East, Ashland, Ohio 44805 PH: 419-207-9400 FX: 419-207-8031 INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS 10/2014

More information

MODELS S3S(D)/S4S(D) and SB3S(D)/SB4S(D)

MODELS S3S(D)/S4S(D) and SB3S(D)/SB4S(D) MODELS SS(D)/S4S(D) and SBS(D)/SB4S(D) SUBMERSIBLE SEWAGE PUMP DUAL SEAL PUMPS INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip

More information

HAZARDOUS LOCATION SUBMERSIBLE PUMP Model S4NVX (Class I, Division 1, Group C & D): FM

HAZARDOUS LOCATION SUBMERSIBLE PUMP Model S4NVX (Class I, Division 1, Group C & D): FM Installation and Service Manual HAZARDOUS LOCATION SUBMERSIBLE PUMP Model S4NVX (Class I, Division 1, Group C & D): FM NOTE! To the installer: Please make sure you provide this manual to the owner of the

More information

Used in Hazardous Locations Class I, Division 1

Used in Hazardous Locations Class I, Division 1 MODELS S4L(X * ), S4LRC/S4LVX *, S4B(X * ), S4K(X * ), H4Q(X * ), S6L(X * ), S6A(X * ) and S8F(X * ) * Used in Hazardous Locations Class I, Division 1 SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND

More information

Used in Hazardous Locations Class I, Division 1

Used in Hazardous Locations Class I, Division 1 MODELS S4L(X * ), S4LRC/S4LVX *, S4B(X * ), S4K(X * ), H4Q(X * ), S6L(X * ), S6A(X * ) and S8F(X * ) * Used in Hazardous Locations Class I, Division 1 SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND

More information

S4HVX Submersible Pump with Explosion-Proof Motor End (Class I, Division 1, Groups C & D): FM For use with product built with USEM motor.

S4HVX Submersible Pump with Explosion-Proof Motor End (Class I, Division 1, Groups C & D): FM For use with product built with USEM motor. Pump Installation and Service Manual S4HVX Submersible Pump with Explosion-Proof Motor End (Class I, Division 1, Groups C & D): FM For use with product built with USEM motor. (Explosion-Proof Motor End)

More information

SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL

SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL HH Shown S4HRC Shown S4M Shown MODELS HH, H4H, S4M, S4P, S4HRC and S4MRC SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL For use with product built with GE motor. NOTE! To the installer:

More information

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt. ME3H SUMP/EFFLUENT PUMP ME3F SUMP/EFFLUENT PUMP ME3H/ME3F SERIES SUBMERSIBLE SUMP AND EFFLUENT PUMPS INSTALLATION AND SERVICE MANUAL Automatic and manual models. Single phase power only 115 or 230 volt.

More information

SIMPLEX, SINGLE PHASE PUMP CONTROL PANEL Model SPC-PANEL Pump Controls for 2 HP Grinder Pumps

SIMPLEX, SINGLE PHASE PUMP CONTROL PANEL Model SPC-PANEL Pump Controls for 2 HP Grinder Pumps Installation and Service Manual SIMPLEX, SINGLE PHASE PUMP CONTROL PANEL Model SPC-PANEL Pump Controls for 2 HP Grinder Pumps NOTE! To the installer: Please make sure you provide this manual to the owner

More information

MODELS HPGF/HPGFH, HPGH/HPGHH

MODELS HPGF/HPGFH, HPGH/HPGHH MODELS HPGF/HPGFH, HPGH/HPGHH SUBMERSIBLE GRINDER PUMPS INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible

More information

NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.

NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system. HYDR-O-RAIL SYSTEM INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system. Item

More information

MODELS H3H, H4H, S4M, S4P, S4HRC and S4MRC SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL

MODELS H3H, H4H, S4M, S4P, S4HRC and S4MRC SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL S4M Shown H3H Shown S4HRC Shown MODELS H3H, H4H, S4M, S4P, S4HRC and S4MRC SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL For use with product built with USEM motor. NOTE! To the installer:

More information

SUBMERSIBLE SEWAGE PUMPS

SUBMERSIBLE SEWAGE PUMPS S3W S3WR MODELS 1750 and 3450 RPM S3W, S3WR SERIES SUBMERSIBLE SEWAGE PUMPS INSTALLATION AND SERVICE MANUAL Single and dual seal. Single and three phase power. NOTE! To the installer: Please make sure

More information

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL 7197 0417 NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains

More information

MODEL S3R(X*) * SUBMERSIBLE SOLIDS HANDLING PUMP. Used in Hazardous Locations Class I, Division 1, Groups C and D INSTALLATION AND SERVICE MANUAL

MODEL S3R(X*) * SUBMERSIBLE SOLIDS HANDLING PUMP. Used in Hazardous Locations Class I, Division 1, Groups C and D INSTALLATION AND SERVICE MANUAL MODEL S3R(X*) * Used in Hazardous Locations Class I, Division 1, Groups C and D SUBMERSIBLE SOLIDS HANDLING PUMP INSTALLATION AND SERVICE MANUAL For use with product built with Marathon motor. (*Hazardous

More information

HYDROMATIC. G1X200/G1LX200 Explosion Proof Submersible Grinder Pumps (Class I, Division 1, Groups C & D): FM. Pump Installation and Service Manual

HYDROMATIC. G1X200/G1LX200 Explosion Proof Submersible Grinder Pumps (Class I, Division 1, Groups C & D): FM. Pump Installation and Service Manual Pump Installation and Service Manual HYDROMATIC G1X200/G1LX200 Explosion Proof Submersible Grinder Pumps (Class I, Division 1, Groups C & D): FM NOTE! To the installer: Please make sure you provide this

More information

MODELS H3H, H4H, S4M, S4P, S4HRC and S4MRC SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL

MODELS H3H, H4H, S4M, S4P, S4HRC and S4MRC SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL S4M Shown H3H Shown S4HRC Shown MODELS H3H, H4H, S4M, S4P, S4HRC and S4MRC SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL For use with product built with USEM motor. NOTE! To the installer:

More information

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party

More information

NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.

NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system. PULTRUDED RAIL SYSTEM INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.

More information

MODELS 4V, 4R, 4VH, 6VH, 4VC and 6VC

MODELS 4V, 4R, 4VH, 6VH, 4VC and 6VC 4V, 4R, 4VH, 6VH 4VC, 6VC MODELS 4V, 4R, 4VH, 6VH, 4VC and 6VC SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL For use with product built with GE motor. NOTE! To the installer: Please make sure you

More information

HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP Installation and Service Manual HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP Model HPGX200 (Class I, Division 1, Groups C & D): FM NOTE! To the installer: Please make sure you provide this manual to the

More information

MODELS WGL20, WGL20H and WGL20F

MODELS WGL20, WGL20H and WGL20F MODELS WGL20, WGL20H and WGL20F GRINDER PUMPS INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party

More information

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL V2 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system.

More information

SPC-PANEL Simplex, Single Phase Pump Control Panel

SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Installation and Service Manual SPC-PANEL Simplex, Single Phase Pump Control Panel Pump Controls for 2 HP Grinder Pumps NOTE! To the installer: Please make sure you provide this manual to the owner

More information

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications. MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL 2 HP Grinder Pump for Residential Applications. NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment

More information

MODELS CX10 and CX20 INDUSTRIAL PUMPS INSTRUCTIONS AND SERVICE MANUAL

MODELS CX10 and CX20 INDUSTRIAL PUMPS INSTRUCTIONS AND SERVICE MANUAL MODELS CX0 and CX20 INDUSTRIAL PUMPS INSTRUCTIONS AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains

More information

SUBMERSIBLE SEWAGE PUMP RECESSED IMPELLER

SUBMERSIBLE SEWAGE PUMP RECESSED IMPELLER Installation and Service Manual SUBMERSIBLE SEWAGE PUMP RECESSED IMPELLER Model S3HRC NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible

More information

SHEF30 Submersible Sump/ Effluent Pump

SHEF30 Submersible Sump/ Effluent Pump Installation and Service Manual SHEF30 Submersible Sump/ Effluent Pump NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party

More information

471 US Hwy 250 East, Ashland, Ohio PH: FX:

471 US Hwy 250 East, Ashland, Ohio PH: FX: 471 US Hwy 250 East, Ashland, Ohio 44805 PH: 419-207-9400 FX: 419-207-8031 INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K3RN(X), K4RN(X), K3VN(X), K4VN(X), K3RH(X), K4RH(X) CENTRIFUGAL

More information

SUBMERSIBLE SOLIDS HANDLING PUMP Models S4T, S8L, S8LA, and S12L

SUBMERSIBLE SOLIDS HANDLING PUMP Models S4T, S8L, S8LA, and S12L Installation and Service Manual SUBMERSIBLE SOLIDS HANDLING PUMP Models S4T, S8L, S8LA, and S12L NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the

More information

HYDR-O-RAIL SYSTEM. Pump Installation and Service Manual

HYDR-O-RAIL SYSTEM. Pump Installation and Service Manual Installation and Service Manual HYDR-O-RAIL SYSTEM NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system.

More information

Pump Installation and Service Manual HRS Hydromatic Retractable System

Pump Installation and Service Manual HRS Hydromatic Retractable System Pump Installation and Service Manual HRS Hydromatic Retractable System NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party

More information

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the

More information

Installation and Service Manual SK50 Submersible Sewage Ejector Pump

Installation and Service Manual SK50 Submersible Sewage Ejector Pump Installation and Service Manual SK50 Submersible Sewage Ejector Pump NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who

More information

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps Now Includes OSP50AB Parts List NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment

More information

PUMP VAULT S.T.E.P. SYSTEM

PUMP VAULT S.T.E.P. SYSTEM Installation and Service Manual PUMP VAULT S.T.E.P. SYSTEM NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the

More information

G2HX Explosion-Proof Submersible Grinder Pumps

G2HX Explosion-Proof Submersible Grinder Pumps Pump Installation and Service Manual G2HX Explosion-Proof Submersible Grinder Pumps (Class 1, Division 1, Groups C & D): FM NOTE! To the installer: Please make sure you provide this manual to the owner

More information

MODELS 4VC(X * ), 6VC(X * ), 4VE(X * ) AND 4RC(X * ) SUBMERSIBLE SOLIDS HANDLING PUMPS. *Used in Hazardous Locations Class I, Division 1, Groups C & D

MODELS 4VC(X * ), 6VC(X * ), 4VE(X * ) AND 4RC(X * ) SUBMERSIBLE SOLIDS HANDLING PUMPS. *Used in Hazardous Locations Class I, Division 1, Groups C & D MODELS 4VC(X * ), 6VC(X * ), 4VE(X * ) AND 4RC(X * ) *Used in Hazardous Locations Class I, Division 1, Groups C & D SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL For use with product

More information

METAL-TO-METAL RAIL SYSTEM INSTALLATION AND SERVICE MANUAL

METAL-TO-METAL RAIL SYSTEM INSTALLATION AND SERVICE MANUAL METAL-TO-METAL RAIL SYSTEM INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the

More information

SUBMERSIBLE GRINDER PUMPS

SUBMERSIBLE GRINDER PUMPS MODELS WGX30/50, WGX30H/50H/75H, VSX30/50 and VHX30/50/75 Hazardous Locations Class I, Division 1, Groups C & D SUBMERSIBLE GRINDER PUMPS INSTALLATION AND SERVICE MANUAL For use with product built with

More information

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST CMP SERIES CPM15-15B (25905F300) CPM15-15B-H/D (25905F301) CPM18-15B (25905F303) CPM18-15B-H/D (25905F304) INDUSTRIAL PUMPS INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST NOTE! To the installer: Please

More information

SUBMERSIBLE BASIN MIXER

SUBMERSIBLE BASIN MIXER MBM(X)20* SERIES 1150 AND 1750 RPM MODELS *For use in Hazardous Locations Class I, Division 1, Groups C & D SUBMERSIBLE BASIN MIXER INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure

More information

MODELS WG/WGX20* GRINDER PUMP. *Used in Hazardous Locations Class I, Division 1, Groups C & D INSTALLATION AND SERVICE MANUAL

MODELS WG/WGX20* GRINDER PUMP. *Used in Hazardous Locations Class I, Division 1, Groups C & D INSTALLATION AND SERVICE MANUAL MODELS WG/WGX20* *Used in Hazardous Locations Class I, Division 1, Groups C & D GRINDER PUMP INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner

More information

INSTALLATION AND SERVICE MANUAL MSKV50 Submersible Sewage Ejector Pump

INSTALLATION AND SERVICE MANUAL MSKV50 Submersible Sewage Ejector Pump INSTALLATION AND SERVICE MANUAL MSKV50 Submersible Sewage Ejector Pump 6096 1009 NOTE! TO THE INSTALLER: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible

More information

SUBMERSIBLE GRINDER PUMP Models HPGF/HPGFH; HPGH/HPGHH

SUBMERSIBLE GRINDER PUMP Models HPGF/HPGFH; HPGH/HPGHH Installation and Service Manual SUBMERSIBLE GRINDER PUMP Models HPGF/HPGFH; HPGH/HPGHH For use with product built with Regal Beloit motor. Effective 04/01/09 NOTE! To the installer: Please make sure you

More information

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2 Pump Installation and Service Manual SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2 NOTE! To the installer: Please make sure you provide this manual to the owner

More information

MODEL HPG200 ADVANCED SUBMERSIBLE GRINDER PUMP INSTALLATION AND SERVICE MANUAL

MODEL HPG200 ADVANCED SUBMERSIBLE GRINDER PUMP INSTALLATION AND SERVICE MANUAL MODEL HPG200 ADVANCED SUBMERSIBLE GRINDER PUMP INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party

More information

MODELS 125M/B, 150M/B and 200M/B

MODELS 125M/B, 150M/B and 200M/B MODELS 25M/B, 50M/B and 200M/B CENTRI-THRIFT CENTRIFUGAL PUMPS NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains

More information

MODELS 125M/B, 150M/B and 200M/B

MODELS 125M/B, 150M/B and 200M/B MODELS 25M/B, 50M/B and 200M/B ½, 2, AND 7½ HP SINGLE AND THREE PHASE CENTRI-THRIFT CENTRIFUGAL PUMPS NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or

More information

MYERS MODELS 4VC & 4VCX

MYERS MODELS 4VC & 4VCX MYERS MODELS 4VC & 4VCX 4" SOLIDS HANDLING WASTEWATER PUMPS STANDARD (4VC) AND HAZARDOUS LOCATION (4VCX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 4VC & 4VCX Solids Handling Wastewater Pumps Cut Your Pumping

More information

MYERS MODELS 4V AND 4VX

MYERS MODELS 4V AND 4VX MYERS MODELS 4V AND 4VX SOLIDS HANDLING WASTEWATER PUMPS STANDARD (4V) AND HAZARDOUS LOCATION (4VX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 4V AND 4VX Solids Handling Wastewater Pumps The Right Choice

More information

NOVUS 3000 STANDARD ELECTRICAL CONTROLS INSTALLATION AND SERVICE MANUAL

NOVUS 3000 STANDARD ELECTRICAL CONTROLS INSTALLATION AND SERVICE MANUAL NOVUS 3000 STANDARD ELECTRICAL CONTROLS INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains

More information

MYERS MODELS 6VC & 6VCX

MYERS MODELS 6VC & 6VCX MYERS MODELS 6VC & 6VCX 6" SOLIDS HANDLING WASTEWATER PUMPS STANDARD (6VC) AND HAZARDOUS LOCATION (6VCX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 6VC & 6VCX Solids Handling Wastewater Pumps High Operating

More information

METAL-TO-METAL RAIL SYSTEM

METAL-TO-METAL RAIL SYSTEM Pump Installation and Service Manual METAL-TO-METAL RAIL SYSTEM NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equip ment or to the responsible party who maintains

More information

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1 Pump Installation and Service Manual W/D/V-A1 Submersible Sump Pump W-A1 D-A1 V-A1 NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible

More information

Pump Installation and Service Manual SK75/100 Submersible Sewage Ejector Pumps

Pump Installation and Service Manual SK75/100 Submersible Sewage Ejector Pumps Pump Installation and Service Manual SK75/100 Submersible Sewage Ejector Pumps NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible

More information

MYERS MODELS 4R AND 4RX

MYERS MODELS 4R AND 4RX MYERS MODELS 4R AND 4RX SOLIDS HANDLING WASTEWATER PUMPS STANDARD (4R) AND HAZARDOUS LOCATION (4RX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 4R AND 4RX Solids Handling Wastewater Pumps The Right Choice

More information

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14 SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

INSTALLATION AND SERVICE INSTRUCTIONS KER KEEN PUMP - e/one Replacement

INSTALLATION AND SERVICE INSTRUCTIONS KER KEEN PUMP - e/one Replacement 471 US Hwy 250 East, Ashland, Ohio 44805 PH: 419-207-9400 FX: 419-207-8031 INSTALLATION AND SERVICE INSTRUCTIONS KER KEEN PUMP - e/one Replacement Progressive Cavity Centrifugal e/one is a registered trademark

More information

Installation and Service Manual JB-1 System Sewage Ejector Pump Package

Installation and Service Manual JB-1 System Sewage Ejector Pump Package Installation and Service Manual JB-1 System Sewage Ejector Pump Package NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party

More information

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible

More information

SP40 Submersible Sewage Ejector Pump

SP40 Submersible Sewage Ejector Pump Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump 6096 1009 NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible

More information

OWNER S MANUAL Submersible Sewage Ejector Pumps

OWNER S MANUAL Submersible Sewage Ejector Pumps OWNER S MANUAL Submersible Sewage Ejector Pumps NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equip ment or to the responsible party who maintains the system.

More information

For use with Hydromatic grinder pumps: HPG200, HPGR200 and HPD200 (shown on cover).

For use with Hydromatic grinder pumps: HPG200, HPGR200 and HPD200 (shown on cover). TG-PRO SYSTEM COMPLETE GRINDER PACKAGE OFFERING INSTALLATION AND SERVICE MANUAL For use with Hydromatic grinder pumps: HPG200, HPGR200 and HPD200 (shown on cover). NOTE! To the installer: Please make sure

More information

INSTALLATION AND SERVICE MANUAL MESPD50/MESPD100 Submersible Effluent Pump

INSTALLATION AND SERVICE MANUAL MESPD50/MESPD100 Submersible Effluent Pump INSTALLATION AND SERVICE MANUAL MESPD50/MESPD100 Submersible Effluent Pump NOTE! TO THE INSTALLER: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party

More information

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13 GRINDER PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #2701-0005 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

HPGB750/1000/1500. Submersible Grinder Pumps. Pump Installation and Service Manual

HPGB750/1000/1500. Submersible Grinder Pumps. Pump Installation and Service Manual Pump Installation and Service Manual HPGB750/1000/1500 Submersible Grinder Pumps NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equpment or to the responsible

More information

Pump Installation and Service Manual SK60 Submersible Sewage Ejector Pump

Pump Installation and Service Manual SK60 Submersible Sewage Ejector Pump Pump Installation and Service Manual SK60 Submersible Sewage Ejector Pump NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party

More information

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible

More information

MYERS MODELS 4RC AND 4RCX

MYERS MODELS 4RC AND 4RCX 3450 RPM 1150 and 1750 RPM MYERS MODELS 4RC AND 4RCX SOLIDS HANDLING WASTEWATER PUMPS (4RCX only) STANDARD (4RC) AND HAZARDOUS LOCATION (4RCX) CONSTRUCTION WWW.FEMYERS.COM MYERS MODELS 4RC AND 4RCX Solids

More information

MODEL TL-PRO SYSTEM COMPLETE GRINDER PACKAGE OFFERING INSTALLATION AND SERVICE MANUAL. For use with HPG(X)200 and HPGR200 Hydromatic Grinder Pumps.

MODEL TL-PRO SYSTEM COMPLETE GRINDER PACKAGE OFFERING INSTALLATION AND SERVICE MANUAL. For use with HPG(X)200 and HPGR200 Hydromatic Grinder Pumps. MODEL TL-PRO SYSTEM COMPLETE GRINDER PACKAGE OFFERING INSTALLATION AND SERVICE MANUAL For use with HPG(X)200 and HPGR200 Hydromatic Grinder Pumps. NOTE! To the installer: Please make sure you provide this

More information

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power Page 1 of 8 equipment and follow handling procedures per OSHA 29 CFR 1910.1030 when handling equipment after waste water source has been connected to system. WARNING: Risk of Asphyxiation. Installer(s)

More information

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump

Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party

More information

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1 Unit Installation and Service Manual A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1 NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping

More information

PRE-PLUMBED SEWAGE SYSTEM

PRE-PLUMBED SEWAGE SYSTEM PRE-PLUMBED SEWAGE SYSTEM Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1910-0009 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

MYERS 4VCDP. 4" Solids Handling

MYERS 4VCDP. 4 Solids Handling MYERS 4VCDP Standard Submersible Dry Pit 4" Solids Handling Wastewater Pumps WWW.FEMYERS.COM TECHNICAL INFORMATION 2 SMOOTH OPERATION The 4VCDP submersible dry pit wastewater pumps are a heavy-duty 4"

More information

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. PEDESTAL SUMP PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1084-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing

More information

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODELS #1073-0001, 1075-0001 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS Models 125M/B, 150M/B and 200M/B ENGLISH: PAGES 2-8 Installation and Service Manual NOTE! To the installer: Please make sure you provide

More information

RAIL SYSTEMS WITH CHECK VALVE

RAIL SYSTEMS WITH CHECK VALVE MODEL 4V, 4R, 4VH, 6VH, 4VC, 6VC, SOLIDS HANDLING PUMPS RAIL SYSTEMS WITH CHECK VALVE INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the

More information

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN AUTOMATIC S33A1 & S33A1C WARNING risk of electric shock.

More information

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1099-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing

More information

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps USER S MANUAL FOR F & Q Submersible Sewage Pumps 100WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and

More information

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump Installation and Service Manual SKV50 Submersible Sewage Ejector NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains

More information

ESE Series Cast Iron Sewage Pumps

ESE Series Cast Iron Sewage Pumps Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................

More information

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS Installation and Servicing Instructions for Myers WHR/WHRH and WHRE Submersible Sump Pumps Single & Three Phase Power Single & Double Seal SINGLE SEAL PUMPS

More information

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps USER S MANUAL FOR F & Q Submersible Sewage Pumps 50WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and

More information

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR 1HP CENTRIFUGAL SUBMERSIBLE EFFLUENT PUMPS

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR 1HP CENTRIFUGAL SUBMERSIBLE EFFLUENT PUMPS 471 US Hwy 250 East, Ashland, Ohio 44805 PH: 419-207-9400 FX: 419-207-8031 INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR 1HP CENTRIFUGAL SUBMERSIBLE EFFLUENT PUMPS P/N O&M-KE102&3 1 Effective

More information