Intermediate weight at 155kg Peak continuous fields up to 3 T for 15mm pole face diameter at 8mm gap Any mounting orientation Fast cycle times

Size: px
Start display at page:

Download "Intermediate weight at 155kg Peak continuous fields up to 3 T for 15mm pole face diameter at 8mm gap Any mounting orientation Fast cycle times"

Transcription

1 OVERVIEW The 5405 dipole electromagnet is a fit, form and function upgrade for the 5403 electromagnet system. This upgrade provides approximately 40% more field for a given pole gap. The 5405 is shipped with a standard set of poles that optimize maximum field but several pole options are available. GMW can also design custom poles that achieve a specific performance. Poles are interchangeable and are available with an axial access bore. FEATURES Intermediate weight at 155kg Peak continuous fields up to 3 T for 15mm pole face diameter at 8mm gap Any mounting orientation Fast cycle times APPLICATIONS EPR FMR MOKE Specification: 6 October

2 MODEL 5405 GENERAL SPECIFICATIONS Dimensions Weight (excluding hoses and water) Standard Pole Face Diameters 600mm W x 322mm D x 355mm H (23.62 inch w x inch D x inch H) 155 kg (342 pounds) 10mm, 38mm and 76mm Coils (series connected) Resistance (20 C) 0.98 Max. Resistance (70 C) 1.20 Max. continuous current 70 A Peak Current (sinusoid) 100 A Peak Current (triangle wave) 120 A Max. continuous Power 6.0 kw Max Instantaneous Power 18.0 kw Inductance 250 mh Water Cooling (supply psi) 4 Litre/min 3 db frequency point 10 Hz Primary Over Temperature Interlock 70 C Secondary Temperature Circuit* Custom * The secondary temperature circuit is mounted on the coils in the same location as the primary circuit. While the primary circuit protects the coils from thermal damage, the secondary circuit can be used to provide early identification of above normal operating temperature. This may provide a yellow alert indicating that the system is within acceptable operating parameters but that some maintenance may be required. Specification: 6 October

3 Figure 1: Comparison of performance between 5403 and 5405 for standard poles. The data reflects the performance of both magnets operating at peak continuous current with coils at maximum spacing. Specification: 6 October

4 Specification: 6 October

5 Specification: 6 October

6 Specification: 6 October

7 Specification: 6 October

8 Specification: 6 October

9 Specification: 6 October

10 Specification: 6 October

11 Specification: 6 October

12 Overbar Option The 5405 includes the option of an overbar configuration. In this configuration, the magnet provides slightly increased field and greatly increased field uniformity in the working region. Note the Ø40mm bore in the overbar. This facilitates the integration of the magnet with a 1½ cryostat. Specification: 6 October

13 Vertical Mounting Bracket Specification: 6 October

14 45 Mounting Bracket Specification: 6 October

15 90 Mounting Bracket Specification: 6 October

16 Flow Meter Option It is often important to be able to identify variations from normal operating procedure. One method for achieving this is to include a flow meter in the return water line. This can present a yellow alert that indicates the system is still operating within acceptable parameters but the system requires attention. This is critical for continuous duty applications. Specification: 6 October

Intermediate weight at 155kg Peak continuous fields up to 3 T for 15mm pole face diameter at 8mm gap Any mounting orientation Fast cycle times

Intermediate weight at 155kg Peak continuous fields up to 3 T for 15mm pole face diameter at 8mm gap Any mounting orientation Fast cycle times OVERVIEW The 5405 dipole electromagnet is a fit, form and function upgrade for the 5403 electromagnet system. This upgrade provides approximately 40% more field for a given pole gap. The 5405 is shipped

More information

INFN LNF DAΦNE. DAΦNE Storage Ring. Laminated Yoke Quadrupole Low carbon steel Magnetil B-C

INFN LNF DAΦNE. DAΦNE Storage Ring. Laminated Yoke Quadrupole Low carbon steel Magnetil B-C and Storage Ring In 1993 the Company was awarded by INFN-LNF a contract for the turn-key construction of the Transfer Lines for the e+e-φ-factory DAΦNE in Frascati - Rome. The contract included resistive

More information

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm]

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm] ACME SCREW LINEAR ACTUATOR ATL 02 Stroke Actuator with DC motor La =Lc + Stroke Lc T OVERALL DIMENSIONS Rear bracket SP Pin Actuator with or 3-phase motor Capacitor Stroke end reed switches FCM Motor cable

More information

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Actuator with. Attachment A1. Lc [mm] Stroke Stroke T [mm] Stroke Stroke

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Actuator with. Attachment A1. Lc [mm] Stroke Stroke T [mm] Stroke Stroke ACME SCREW LINEAR ACTUATOR CLA 20 OVERALL DIMENSIONS Stroke La =Lc + Stroke Lc T La =Lc + Stroke Lc T Rear bracket SP Pin FC switches and potentiometer Attachment A1 Attachment A2 Motor cable length 0.3

More information

1. This question is about electrical energy and associated phenomena.

1. This question is about electrical energy and associated phenomena. 1. This question is about electrical energy and associated phenomena. Electromagnetism The current in the circuit is switched on. electromagnet State Faraday s law of electromagnetic induction and use

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

ACME SCREW LINEAR ACTUATOR. Current [A] PERFORMANCES with AC 3-phase 50 Hz 230/400 V or 1-phase 50 Hz 230 V motor

ACME SCREW LINEAR ACTUATOR. Current [A] PERFORMANCES with AC 3-phase 50 Hz 230/400 V or 1-phase 50 Hz 230 V motor ACME SCREW LINEAR ACTUATOR CLA 28 OVERALL DIMENSIONS La = Lc + Stroke Stroke Lc T Standard head with threaded hollow bore BA Motor cable length 0.3 m Bronze bushes depth 17 Lc [mm] T [mm] Length [mm] +

More information

QUESTION BANK SPECIAL ELECTRICAL MACHINES

QUESTION BANK SPECIAL ELECTRICAL MACHINES SEVENTH SEMESTER EEE QUESTION BANK SPECIAL ELECTRICAL MACHINES TWO MARK QUESTIONS 1. What is a synchronous reluctance 2. What are the types of rotor in synchronous reluctance 3. Mention some applications

More information

Phys102 Lecture 20/21 Electromagnetic Induction and Faraday s Law

Phys102 Lecture 20/21 Electromagnetic Induction and Faraday s Law Phys102 Lecture 20/21 Electromagnetic Induction and Faraday s Law Key Points Induced EMF Faraday s Law of Induction; Lenz s Law References SFU Ed: 29-1,2,3,4,5,6. 6 th Ed: 21-1,2,3,4,5,6,7. Induced EMF

More information

Modeling and Optimization of a Linear Electromagnetic Piston Pump

Modeling and Optimization of a Linear Electromagnetic Piston Pump Fluid Power Innovation & Research Conference Minneapolis, MN October 10 12, 2016 ing and Optimization of a Linear Electromagnetic Piston Pump Paul Hogan, MS Student Mechanical Engineering, University of

More information

The use of Simulation in Electric Machine Design Stefan Holst, CD-adapco

The use of Simulation in Electric Machine Design Stefan Holst, CD-adapco The use of Simulation in Electric Machine Design Stefan Holst, CD-adapco Motivation How often can a machine be started within an hour In Hybrids, what effect has the adjacent combustion drive train Space

More information

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS BSA 10 AC motor Stroke La =Lc + Stroke Lc Capacitor T Rear bracket SP Pin Standard head with threaded hollow bore BA 80 depth 17 Stroke end reed switches FCM

More information

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor ACME SCREW LINEAR ACTUATOR ATL 10 AC motor Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore 80 BA depth 17 Stroke end reed switches FCM

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Update. This week A. B. Kaye, Ph.D. Associate Professor of Physics. Michael Faraday

Update. This week A. B. Kaye, Ph.D. Associate Professor of Physics. Michael Faraday 10/26/17 Update Last week Completed Sources of Magnetic Fields (Chapter 30) This week A. B. Kaye, Ph.D. Associate Professor of Physics (Chapter 31) Next week 30 October 3 November 2017 Chapter 32 Induction

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

LECTURE 27 SERVO VALVES FREQUENTLY ASKED QUESTIONS

LECTURE 27 SERVO VALVES FREQUENTLY ASKED QUESTIONS LECTURE 27 SERVO VALVES FREQUENTLY ASKED QUESTIONS 1. Define a servo valve Servo valve is a programmable orifice. Servo valve is an automatic device for controlling large amount of power by means of very

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION Star/delta starter Description: The electromagnetic starters LT 3 Dxx series are devices designed for remote control, direct control and protection of induction motors coiled and

More information

EKM Series Motors. For Aerospace & Defense Applications

EKM Series Motors. For Aerospace & Defense Applications EKM Series Motors For Aerospace & Defense Applications EKM Series Motors Table of Contents Introduction........................................................................................ 4 Introduction

More information

Page 1. Design meeting 18/03/2008. By Mohamed KOUJILI

Page 1. Design meeting 18/03/2008. By Mohamed KOUJILI Page 1 Design meeting 18/03/2008 By Mohamed KOUJILI I. INTRODUCTION II. III. IV. CONSTRUCTION AND OPERATING PRINCIPLE 1. Stator 2. Rotor 3. Hall sensor 4. Theory of operation TORQUE/SPEED CHARACTERISTICS

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines Department of Electrical Engineering Lecture Introduction to Electrical Machines 1 In this Lecture Induction motors and synchronous machines are introduced Production of rotating magnetic field Three-phase

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date: CSDA Best Practice Title: Hi-Cycle Concrete Cutting Equipment Issue No: CSDA-BP-010 : Oct 1, 2010 Revised : Introduction Hi-cycle/high frequency concrete cutting equipment has become more prevalent in

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) 41-242.5E 2 Typical 60 Hertz time product curves for the type CWP-1 relay are shown in Figure 4 with 100 volts

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

High pressure washpipe assembly with integral reservoir. Revision 1 October 10, 2017

High pressure washpipe assembly with integral reservoir. Revision 1 October 10, 2017 Kalsi Seals Handbook Chapter E6 High pressure washpipe assembly with integral reservoir Revision 1 October 10, 2017 Individual chapters of the Kalsi Seals Handbook are periodically updated. To determine

More information

ELECTROMAGNETIC INDUCTION. FARADAY'S LAW

ELECTROMAGNETIC INDUCTION. FARADAY'S LAW 1. Aim. Physics Department Electricity and Magnetism Laboratory. ELECTROMAGNETIC INDUCTION. FARADAY'S LAW Observe the effect of introducing a permanent magnet into a coil. Study what happens when you introduce

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Chapter Review USING KEY TERMS UNDERSTANDING KEY IDEAS. Skills Worksheet. Multiple Choice

Chapter Review USING KEY TERMS UNDERSTANDING KEY IDEAS. Skills Worksheet. Multiple Choice Skills Worksheet Chapter Review USING KEY TERMS Complete each of the following sentences by choosing the correct term from the word bank. electric motor transformer magnetic force electric generator magnetic

More information

CLA 25 AC motor ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Rear bracket SP. Stroke. Capacitor. Standard head with threaded hollow bore BA

CLA 25 AC motor ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Rear bracket SP. Stroke. Capacitor. Standard head with threaded hollow bore BA ACME SCREW LINEAR ACUAOR CLA 5 AC motor OVERALL DIMENSIONS Stroke La = + Stroke Capacitor La = + Stroke Rear bracket SP Pin Standard head with threaded hollow bore BA 1 Attachment A1 Attachment A depth

More information

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor ACME SCREW LINEAR ACTUATOR Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore BA depth 17 Stroke end reed switches FCM Lenght Stroke 300

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Welcome to the SEI presentation on the basics of electricity

Welcome to the SEI presentation on the basics of electricity Welcome to the SEI presentation on the basics of electricity 1 Electricity is a secondary energy source, meaning that it is produced from other, primary, energy sources. There are several primary sources

More information

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS LENGTH

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS LENGTH BALL SCREW LINEAR ACTUATOR BSA 2 OVERALL DIMENSIONS Stroke La =Lc + Stroke Lc T Capacitor Rear bracket Pin SP Standard head with threaded hollow bore BA depth 7 Stroke end reed switches FCM (brake motor)

More information

The instantaneous torque is pulsating. The average value of the torque is

The instantaneous torque is pulsating. The average value of the torque is Problems 113 2. ω m = ω s ω r. Both stator and rotor windings carry ac currents at different frequencies and the motor runs at an asynchronous speed (ω m 6¼ ω s, ω m 6¼ ω r ). From Eq. 3.50, the torque

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

The Electrical System. by Kate Elfers and Mun Yong Jang

The Electrical System. by Kate Elfers and Mun Yong Jang The Electrical System by Kate Elfers and Mun Yong Jang Important links: Video overview of system: https://www.youtube.com/watch? v=w94iksaqwuo Understanding AC vs DC animation: https://www.youtube.com/watch?

More information

General Purpose Permanent Magnet Motor Drive without Speed and Position Sensor

General Purpose Permanent Magnet Motor Drive without Speed and Position Sensor General Purpose Permanent Magnet Motor Drive without Speed and Position Sensor Jun Kang, PhD Yaskawa Electric America, Inc. 1. Power consumption by electric motors Fig.1 Yaskawa V1000 Drive and a PM motor

More information

DEUTROFLUX UWE Universal Stationary Magnetic Particle Crack Detectors

DEUTROFLUX UWE Universal Stationary Magnetic Particle Crack Detectors DEUTROFLUX UWE Universal Stationary Magnetic Particle Crack Detectors Reliable testing for cracks in all directions Optionally with Memory II: Operation via Siemens Touch Panel with parameter memory (e.

More information

DIN Panel Meters Long Scale

DIN Panel Meters Long Scale DIN Panel Meters Long Scale A range of 72mm and 96mm DIN style panel meters measuring all electrical parameters and featuring moving coil movements. All meters incorporate slide-in dials and terminal covers

More information

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59. Single Pole Circuit Protectors 55 Multi-Pole Circuit Protectors 56 Configurations 58 Operating Characteristics 59 Delay Curves 60 Specifications 61 Decision Tables 62 SINGLE POLE CIRCUIT PROTECTORS The

More information

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Length [mm] Stroke Stroke LENGTH

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Length [mm] Stroke Stroke LENGTH BALL SCREW LINEAR ACUAOR BSA 11 AC motor OVERALL DIMENSIONS Stroke La =Lc + Stroke Lc Capacitor Rear bracket SP Pin Standard head with threaded hollow bore BA 80 depth17 Stroke end reed switches FCM (brake

More information

SPH3U UNIVERSITY PHYSICS

SPH3U UNIVERSITY PHYSICS SPH3U UNIVERSITY PHYSICS ELECTRICITY & MAGNETISM L (P.599-604) The large-scale production of electrical energy that we have today is possible because of electromagnetic induction. The electric generator,

More information

Modern Design for Variable Speed Motor-Generators:

Modern Design for Variable Speed Motor-Generators: Modern Design for Variable Speed Motor-Generators: Asynchronous and Synchronous Electric Machinery Options for Pumped Storage Power Plants SHF - Enhancing Hydropower plants Grenoble, April 9-11, 2014 1

More information

TECHNICAL TERMS AND ABBREVIATIONS

TECHNICAL TERMS AND ABBREVIATIONS THIRD REVISED SHEET NO. 3.1 CANCELS SECOND REVISED SHEET NO. 3.1 TECHNICAL TERMS AND ABBREVIATIONS ALTERNATING CURRENT (A-C): AMPERE: BASE RATES: BRITISH THERMAL UNIT (BTU): CAPACITOR or CAPACITANCE: CAPACITY

More information

E280 DIAMETER FRAMES

E280 DIAMETER FRAMES E28 DIAMETER FRAMES MODEL NUMBER CODE...E28 FRAME To construct a motor listing, select the combination of features required, and put all the coded information in the proper sequence. Please account for

More information

AXIAL FLUX PERMANENT MAGNET BRUSHLESS MACHINES

AXIAL FLUX PERMANENT MAGNET BRUSHLESS MACHINES AXIAL FLUX PERMANENT MAGNET BRUSHLESS MACHINES Jacek F. Gieras, Rong-Jie Wang and Maarten J. Kamper Kluwer Academic Publishers, Boston-Dordrecht-London, 2004 TABLE OF CONTENETS page Preface v 1. Introduction

More information

Vibratory Downhole Tool Technologies with Application to Horizontal Drilling and Casing Installation

Vibratory Downhole Tool Technologies with Application to Horizontal Drilling and Casing Installation Vibratory Downhole Tool Technologies with Application to Horizontal Drilling and Casing Installation 2/5/2013 Roger L. Schultz TTS Drilling Solutions Presentation Overview Frictional Forces, Vibratory

More information

PHY 152 (ELECTRICITY AND MAGNETISM)

PHY 152 (ELECTRICITY AND MAGNETISM) PHY 152 (ELECTRICITY AND MAGNETISM) ELECTRIC MOTORS (AC & DC) ELECTRIC GENERATORS (AC & DC) AIMS Students should be able to Describe the principle of magnetic induction as it applies to DC and AC generators.

More information

Using the IMV s standard ECO system to improve shock capability. Optimising Vibration Test Systems for Battery Testing using ECO Technology

Using the IMV s standard ECO system to improve shock capability. Optimising Vibration Test Systems for Battery Testing using ECO Technology Using the IMV s standard ECO system to improve shock capability Optimising Vibration Test Systems for Battery Testing using ECO Technology Dr John Goodfellow IMV Europe Ltd Copyright IMV IMV CORPORATION

More information

Electromagnets. Electromagnets

Electromagnets. Electromagnets Electromagnets Field Control Introduction and Power 63 Electromagnets EM4-HVA, EM7-HV Continuously adjustable poles allow rapid air gap changes to suit individual experiments, assuring magnet versatility

More information

Chapter 29 Electromagnetic Induction

Chapter 29 Electromagnetic Induction Chapter 29 Electromagnetic Induction Lecture by Dr. Hebin Li Goals of Chapter 29 To examine experimental evidence that a changing magnetic field induces an emf To learn how Faraday s law relates the induced

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1 University f Jordan School of Engineering Department of Mechatronics Engineering Electrical Machines Lab Eng. Osama Fuad Eng. Nazmi Ashour EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1 OBJECTIVES To

More information

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES YEAR / SEM : IV / VII UNIT I SYNCHRONOUS RELUCTANCE

More information

Support and Infrastructure

Support and Infrastructure Support and Infrastructure SoLID Director s Review Whit Seay February 23, 2014 SoLID Experimental Set-ups Design a system for mounting experimental apparatus that can be utilized by both set-ups. Integrate

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

APGENCO/APTRANSCO Assistant Engineer Electrical Previous Question Papers Q.1 The two windings of a transformer is conductively linked. inductively linked. not linked at all. electrically linked. Q.2 A

More information

AN INTRODUCTION TO THE USE OF INVERTER POWER SUPPLIES IN GLOBAR APPLICATIONS HOW TO IMPROVE THE POWER FACTOR OF THE SYSTEM.

AN INTRODUCTION TO THE USE OF INVERTER POWER SUPPLIES IN GLOBAR APPLICATIONS HOW TO IMPROVE THE POWER FACTOR OF THE SYSTEM. AN INTRODUCTION TO THE USE OF INVERTER POWER SUPPLIES IN GLOBAR APPLICATIONS HOW TO IMPROVE THE POWER FACTOR OF THE SYSTEM. Stanley F. Rutkowski lll, Senior Applications Engineer, RoMan Manufacturing The

More information

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1 It is the mark of an educated mind to be able to entertain a thought without accepting it. DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1 1. Explain the Basic concepts of rotating machine. 2. With help

More information

850 F. 80 mm 170 mm 58 mm 6.1 kg IH mm 320 mm 108 mm 43.5 kg IH mm 400 mm 160 mm 83 kg IH mm 540 mm 192 mm 190 kg IH 210

850 F. 80 mm 170 mm 58 mm 6.1 kg IH mm 320 mm 108 mm 43.5 kg IH mm 400 mm 160 mm 83 kg IH mm 540 mm 192 mm 190 kg IH 210 The right heater for your application The choice of a simatherm Induction Heater depends generally on the dimensions and the weight of workpieces. The chart below assists making the right choice. D (mm)

More information

M. A. Green, and S. Yu Lawrence Berkeley National Laboratory, Berkeley CA 94720, USA

M. A. Green, and S. Yu Lawrence Berkeley National Laboratory, Berkeley CA 94720, USA LBNL-48445 SCMAG-749 SUPERCONDUCTING MAGNETS FOR INDUCTION LINAC PHASE-ROTATION IN A NEUTRINO FACTORY M. A. Green, and S. Yu Lawrence Berkeley National Laboratory, Berkeley CA 94720, USA ABSTRACT The neutrino

More information

Kollmorgen Frameless Motor Selection Guide

Kollmorgen Frameless Motor Selection Guide Kollmorgen Frameless Motor Selection Guide KBM Series Brushless Motors Kollmorgen. Every solution comes from a real understanding of OEM challenges. The ever-escalating demands of the marketplace mean

More information

DESIGN OF COMPACT PERMANENT-MAGNET SYNCHRONOUS MOTORS WITH CONCENTRATED WINDINGS

DESIGN OF COMPACT PERMANENT-MAGNET SYNCHRONOUS MOTORS WITH CONCENTRATED WINDINGS DESIGN OF COMPACT PERMANENT-MAGNET SYNCHRONOUS MOTORS WITH CONCENTRATED WINDINGS CSABA DEAK, ANDREAS BINDER Key words: Synchronous motor, Permanent magnet, Concentrated winding. The design and comparison

More information

The galvanic separation of the primary or actuating circuit and the load circuits

The galvanic separation of the primary or actuating circuit and the load circuits RELAY BASICS Relays are electro magnetically operated switches. An actuating current on a coil operates one or more galvanically separated contacts or load circuits. The electro mechanical relay is a remote

More information

Kollmorgen Frameless Motor Selection Guide

Kollmorgen Frameless Motor Selection Guide Kollmorgen Frameless Motor Selection Guide KBM Series Brushless Motors Kollmorgen. Every solution comes from a real understanding of OEM challenges. The ever-escalating demands of the marketplace mean

More information

Synchronous Generators I. Spring 2013

Synchronous Generators I. Spring 2013 Synchronous Generators I Spring 2013 Construction of synchronous machines In a synchronous generator, a DC current is applied to the rotor winding producing a rotor magnetic field. The rotor is then turned

More information

Permanent Magnet Synchronous Motor. High Efficiency Industrial Motors

Permanent Magnet Synchronous Motor. High Efficiency Industrial Motors VoltPro is a new industrial motor range to meet high efficiency needs of industry by higher level of IE4 efficiency class. Main advantage of this product is cost effective solution ensured by using standard

More information

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR 100 CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR 6.1 INTRODUCTION Conventional energy resources are not sufficient to meet the increasing electrical power demand. The usages of

More information

1.0 Installation Wiring

1.0 Installation Wiring 1.0 Installation Wiring DX Firebox is designed to be an electronic replacement for Pontiac & Ford buzz coils when operated on DC. Installation may be positive or negative ground. Simply observe the RED

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Wireless Charger. Inductive charging system for AGVs

Wireless Charger. Inductive charging system for AGVs Wireless Charger Inductive charging system for AGVs Inductive charging system for Automated Guided Vehicles DC/DC converter charging manager Power pickup Supply module Charging mat Functional principles

More information

Axial Flux Permanent Magnet Brushless Machines

Axial Flux Permanent Magnet Brushless Machines Jacek F. Gieras Rong-Jie Wang Maarten J. Kamper Axial Flux Permanent Magnet Brushless Machines Second Edition Springer Contents 1 Introduction 1 1.1 Scope 1 1.2 Features 1 1.3 Development of AFPM Machines

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

2014 ELECTRICAL TECHNOLOGY

2014 ELECTRICAL TECHNOLOGY SET - 1 II B. Tech I Semester Regular Examinations, March 2014 ELECTRICAL TECHNOLOGY (Com. to ECE, EIE, BME) Time: 3 hours Max. Marks: 75 Answer any FIVE Questions All Questions carry Equal Marks ~~~~~~~~~~~~~~~~~~~~~~~~~~

More information

Electro-Proportional Terms and Definitions

Electro-Proportional Terms and Definitions Electro-Proportional Terms and Definitions Valve Deadband The span of operation where there is no flow or pressure output for some specified range of command Hydraulic Valve Gain The characteristic relating

More information

Electromagnetic Induction Chapter Questions. 1. What is the Electromagnetic Force (EMF)? What are the units of EMF?

Electromagnetic Induction Chapter Questions. 1. What is the Electromagnetic Force (EMF)? What are the units of EMF? Electromagnetic Induction Chapter Questions 1. What is the Electromagnetic Force (EMF)? What are the units of EMF? 2. The discovery of electric currents generating an magnetic field led physicists to look

More information

European Conference on Nanoelectronics and Embedded Systems for Electric Mobility

European Conference on Nanoelectronics and Embedded Systems for Electric Mobility European Conference on Nanoelectronics and Embedded Systems for Electric Mobility emobility emotion 25-26 th September 2013, Toulouse, France 6-phase Fault-Tolerant Permanent Magnet Traction Drive for

More information

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads 22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil

More information

Figure 1: Relative Directions as Defined for Faraday s Law

Figure 1: Relative Directions as Defined for Faraday s Law Faraday s Law INTRODUCTION This experiment examines Faraday s law of electromagnetic induction. The phenomenon involves induced voltages and currents due to changing magnetic fields. (Do not confuse this

More information

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani Electro - 9 Hydraulics & Pneumatics 2 Electro Hydraulic Press The hydraulic press is controlled via the electrical control panel. Electrical signals are used to activate the valves in the hydraulic installation.

More information

Standard AC Motors E-53

Standard AC Motors E-53 Standard AC E-53 Overview Standard AC Reversible Reversible Three-Phase Reversible Electromagnetic Brake Clutch & Brake Low-Speed Synchronous Torque IP67 Watertight, Dust-Resistant AC Speed Control AC

More information

fact sheet Masoneilan * 8007/8008 Series Electro-pneumatic Transducers GE Energy Nozzle Design Reducing Effects of Vibration Overview

fact sheet Masoneilan * 8007/8008 Series Electro-pneumatic Transducers GE Energy Nozzle Design Reducing Effects of Vibration Overview GE Energy Masoneilan * 8007/8008 Series Electro-pneumatic Transducers fact sheet Nozzle Design Reducing Effects of Vibration Overview Model 8007 and 8008 electro-pneumatic transducers convert a low-power

More information

Synchronous Generators I. EE 340 Spring 2011

Synchronous Generators I. EE 340 Spring 2011 Synchronous Generators I EE 340 Spring 2011 Construction of synchronous machines In a synchronous generator, a DC current is applied to the rotor winding producing a rotor magnetic field. The rotor is

More information

ACM-D Series (Patented)

ACM-D Series (Patented) ACM-D Series (Patented) High Force Iron Core Brushless Linear Motor Iron core technology Low cogging force Integrated with hall sensors High force Zero net attraction force 1 ACM2-D Specifications Model

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Stray Losses in Power Transformers

Stray Losses in Power Transformers Stray Losses in Power Transformers Stray Losses in Power Transformers Pradeep Ramaswamy Design & Development Engineer Pradeep.Ramaswamy@spx.com 2 Agenda 1. Definition 2. Formation & Characteristics 3.

More information

English for Electrical Engineers

English for Electrical Engineers University of Kurdistan Department of Electrical & Computer Engineering English for Electrical Engineers H. Bevrani October, 2017 1 Contents Unit 1. Current, voltage and resistance... 3 Unit 2. Electrical

More information

Sold & Serviced By: ELECTROMATE. Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099

Sold & Serviced By: ELECTROMATE. Toll Free Phone (877) SERVO98 Toll Free Fax (877) SERV099 AVM Specifications Model Units AVM 12-6.4 AVM 19-5 AVM 20-10 AVM24-5 AVM24-10 Stroke mm 6.4 5 10 5 10 Force sensitivity (at mid stroke) N/A 0.57 1.75 2.00 3.00 3.90 Back EMF constant V/m/s 0.57 1.75 2.00

More information

Control Relays Overview

Control Relays Overview Control Relays Overview DESIGN FEATURES Among the advances Agastat Control Relays offer over existing designs is a unique contact operating mechanism. An articulated arm assembly amplifies the movement

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Steering Module Test Simulator SMTS

Steering Module Test Simulator SMTS Steering Module Test Simulator Overview The Steering Module Test Simulator () from MB Dynamics is a non-hydraulic turnkey lab test system, offering accurate, reliable and repeatable in-laboratory simulations

More information

Remote Heat Station 40kW; kHz User s Guide

Remote Heat Station 40kW; kHz User s Guide Remote Heat Station 40kW; 35 400kHz User s Guide RHS-40 Rev. A 1/4/10 Table of Contents 1. SPECIFICATIONS AND FEATURES...3 2. GETTING STARTED...4 3. CONNECTIONS...5 4. LOAD STATION TUNING...6 2 1. Specifications

More information

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS 66 CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS 4.1 INTRODUCTION In this chapter, the prototype hardware development of proposed

More information

Experiment 10. Faraday s Law of Induction. One large and two small (with handles) coils, plastic triangles, T-base BNC connector, graph paper.

Experiment 10. Faraday s Law of Induction. One large and two small (with handles) coils, plastic triangles, T-base BNC connector, graph paper. PHYSICS 171 UNIVERSITY PHYSICS LAB II Experiment 10 Faraday s Law of Induction Equipment: F Supplies: unction Generator, Oscilloscope. One large and two small (with handles) coils, plastic triangles, T-base

More information

This chapter gives details of the design, development, and characterization of the

This chapter gives details of the design, development, and characterization of the CHAPTER 5 Electromagnet and its Power Supply This chapter gives details of the design, development, and characterization of the electromagnets used to produce desired magnetic field to confine the plasma,

More information