SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor
|
|
- Sarah Hall
- 5 years ago
- Views:
Transcription
1 User Manual English SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor Memosens Protocol Latest Product Information:
2 2 Safety Instructions WARNING Failure to observe this warning may result in serious injury. The safety alert symbol on the nameplate means: Read these instructions for use, observe the Specifications, and follow the Safety Instructions. Safety Instructions Make sure that the sensor is without visible mechanical damage. Use the sensor for the intended purpose only. Hazards due to pressure, temperature, aggressive media or other influences are possible, depending on the location of use. Therefore, the installation, operation, and servicing of the sensor shall only be carried out by suitably trained personnel authorized by the operating company. Manipulations of the equipment other than described in the user manual are not permitted. The sensors have been developed in compliance with the applicable European directives and standards. Be sure to follow the instructions given in this user manual for connecting and operating the SE 655 sensors. Observe the specified ranges for ambient temperature and process temperature to ensure safe use of the sensors. Take care to maintain the IP 68 protection when installing the sensor. (Use original gaskets, insert the cables in a professional manner.) Make sure that the gaskets are securely in place. Otherwise, the assembly is not tight. Do not dismantle the sensor as long as the process medium is under pressure. Intended Use The SE 655 toroidal conductivity sensors with Memosens protocol are particularly suited for applications in the chemical industry and for process engineering. The SE 655 sensor is equipped with Memosens technology. This allows an integrated sensor diagnostics as well as the saving of calibration data, operating time, sensor designation and serial number in the sensor. The serial number is also printed in the quality certificate and on the packaging label. Using the Memosens protocol for data transmission allows the above mentioned sensor data to be transmitted to the measuring device and to be saved and processed. Thanks to the large measuring range over six decades and the high chemical resistance of the process-wetted parts made of PEEK, almost every conceivable application is possible, such as concentration determination of acids, bases and salt solutions, monitoring of product quality or phase separation of product mixtures.
3 Table of Contents 3 Safety Instructions...2 Intended Use...2 Specifications...4 Chemical Resistance...5 Temperature and Pressure Resistance...6 Electrical Connection...7 Identifying the Sensor...7 Assembly...8 Dimension Drawings...11 Accessories...13
4 4 Specifications General Cell factor (installation factor 1.98/cm for adaption to installation conditions, see page 10) Measuring range ms/cm Resolution ms/cm Measurement error ( C) ± (0.005 ms/cm % meas. value) Measurement error ± (0.010 ms/cm % meas. value) (> 100 C) SE 655 material PEEK Process temperature Temperature response time t 90 (DIN 746-1) C G 3/4 (SE 655N-GEFFT0AM) Approx. 7 min Ambient temperature C Storage temperature C Process pressure bar Temperature detector Pt1000 (Class A acc. to IEC 60751) Installation Cable Length Connection Ingress protection (EN 60529) Weight G 3/4 (SE 655N-GEFFT0AM) NPT 1 adapter Steel with ZU1046 NPT 1 adapter PEEK with ZU1052 ANSI 2 flange PVDF with ZU1035 DN 50 flange Steel with ZU0343 DN 50 flange PVDF with ZU m (extendable up to 100 m) Ferrules IP 68 (sensor mounted, with original gasket) Approx. 1 kg
5 Specifications 5 Chemical Resistance - Depending on the Type, Concentration, and Temperature of the Process Medium Sensor Gaskets Medium Concentration Material: PEEK Material: FKM (other materials on request) Sodium hydroxide % C ( F) Not suitable solution NaOH Nitric acid % C ( F) C ( F) HNO % 20 C (68 F) C ( F) Phosphoric acid % C ( F) C ( F) H3PO4 Sulfuric acid % C ( F) C ( F) H2SO % 20 C (68 F) C ( F) Hydrochloric acid % C ( F) C ( F) HCl % C ( F) C ( F)
6 6 Specifications Temperature and Pressure Resistance SE 655 PEEK P/T Diagram (SE 655N-GEFFT0AM) Pressure [bar] Temperature [ C] Fig. 1 Pressure/temperature resistance P/T Diagram (Assembled Version) Pressure [bar] DN 50, stainless steel (ZU 0343) Loose flange DN50, PVDF (ZU 0344), ANSI 2, PVDF (ZU1035) Thread adapter NPT 1, steel (ZU1046) NPT 1, steel (ZU1052) Temperature [ C] Fig. 2 Pressure/temperature curves depending on the process installation
7 Specifications 7 Electrical Connection Connect the sensor cable to your measuring device. Refer to the user manual of your measuring device for information on the electrical connection. For further information, see S Fig. 3 Wire assignment of Memosens cable Brown Green Yellow White Gray Power supply + RS485 (A) RS485 (B) Power supply (GND) Shield The shielding wire is included in the package. Note: First, pass the sensor cable through the cable gland. Then, secure the clamp S on the bare shielding braid of the cable. Identifying the Sensor SE655N-GEFFT0AM Electrodeless Conductivity Sensor Berlin Made in Germany Serial No.: Temp 0to110 C P rel 0to20bar The orientation symbol shows the position of the sensor bore. Fig. 4 Model designation / nameplate of SE655N-GEFFT0AM sensor
8 8 Assembly Assembly, with PTFE washer (for flange protection) Max. torque 20 Nm, 36 mm wrench Nut (included with sensor) Replacement: ZU 0340N Sensor: SE 655N-GEFFT0AM O-ring included with sensor) Replacement: ZU 0340N PTFE washer DN 50 ZU 0342N (optional) Stainless steel flange ZU 0343 Fig. 6 Assembly with stainless steel DN 50 flange, with PTFE washer Assembly with NPT 1 adapter Max. torque 20 Nm, 41 mm wrench NPT 1 adapter ZU1046 (1.4571) ZU1052 (PEEK) O-ring (included with sensor) Sensor Fig. 7 Assembly with NPT 1 adapter
9 Assembly 9 Assembly with stainless steel DN 50 flange, without PTFE washer (flange wetted by process medium) Max. torque 20 Nm, 36 mm wrench Nut Flange kit, ZU 0343 (stainless steel) DN 50 PN 16 Gasket (O-ring) Sensor Flange kit, ZU 0344 DN 50 PN 10 PVDF Loose flange (PP-GF) Nut Flange (PVDF) Flange kit, ZU 1035 ANSI 2", 150 lbs PVDF Loose flange (PP-GF) Nut Flange (PVDF) Fig. 8 Assembly with DN 50, ANSI 2 loose flange
10 10 Assembly Installation Conditions Min. distance 15 mm (no change of cell factor) With a distance of less than 15 mm to metallic tank or pipe walls, the cell factor will be reduced. With insulating walls, the cell factor will increase. 15 mm Fig. 9 Minimum extent of the free field without change of the cell factor Make sure that the sensor is correctly positioned. Minimum water level in the pipe (sensor head completely wetted) a max 100 Fig. 10 Typical installation in a pipe Installation factor 1,40 1,20 Insulating pipe wall 1,00 Conductive pipe wall 0, Fig. 11 Influence of wall distance to installation factor Distance a to pipe wall [mm]
11 151 [5.945] 98 [3.858] 163 [6.417] 35 [1.378] Dimension Drawings 11 Stainless steel Stainless steel Stainless steel SW36 [1.417A/F] NPT 1" G 3/4 SW41 [1.614A/F] 39 [1.535] 24 [0.945] 47 [1.85] 15,5 [0.61] 27,5 [1.08] across flats A/F Fig. 12 Dimensions of the sensor in mm [inches]
12 12 Dimension Drawings Flange kit DN 50 PN 16, 316L, ZU 0343 Flange (stainless steel) NPT 1" 41 mm A/F 4 x NPT 1 stainless steel ZU1046 NPT 1 PEEK ZU Flange kit DN 50 PN 10, PVDF, ZU 0344 Loose flange Flange (PVDF) 4 x Flange kit ANSI 2", 150 lbs ZU 1035 Loose flange (PP-GF) Flange 8 x Fig.13 Dimensions of the flanges and adapters in mm
13 Accessories 13 Order No. NPT 1 adapter Material: stainless steel ZU 1046 NPT 1 adapter Material: PEEK ZU 1052 Flange, DN 50 PN 16 Material: 316 L ZU 0343 When measuring in aggressive media, you require sealing set C. Flange, DN 50 PN 10 Material: PVDF ZU 0344 Flange, ANSI 2", Material: PVDF ZU lbs Sealing set A Nut + FKM O-ring (3 x) ZU 0340N spare part for SE655N-GEFFT0AM Sealing set C PTFE washer DN 50 ZU 0342N (protects ZU 0343 flange against aggressive media) O-rings Material: FKM O-Ring 30x2,5 FKM Material: EPDM-FDA O-Ring 30x2,5 EPDM-FDA Material: FFKM O-Ring 30x2,5 FFKM Conductivity standard KCl 0.1 mol/l 250 ml ms/cm + 1.5% CS-C12880K/500 For more accessories enabling the installation in immersion fittings or flow-through fittings, refer to our website:
14
15
16 Knick Elektronische Messgeräte GmbH & Co. KG Beuckestr Berlin Germany Phone: Fax: Copyright 2018 Subject to change Version: 1.2 This document was last updated on April 20, 2018 The latest documents are available for download on our website under the corresponding product description TA-SE655N-MSProt-KNE01
Flow-Through Fitting ARF 215
Flow-Through Fitting ARF 215 Standard Models Model for Pressurized Sensors Latest Product Information: www.knick.de Warranty Defects occurring within 1 year from delivery date shall be remedied free of
More informationIndumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications
Technical Information Indumax P CLS50 Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications Application CLS50 conductivity sensors are especially suitable
More informationSensoGate WA 131 M. User Manual. Sensor Lock-Gate
SensoGate WA 131 M User Manual Sensor Lock-Gate Warranty Defects occurring within 1 year from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender). 2010 Subject
More informationSensoGate WA 130 User Manual
SensoGate WA 130 User Manual Sensor Lock-Gate Warranty Defects occurring within 1 year from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender). 2011 Subject
More informationSensoGate WA 130 H. User Manual. Retractable Fitting
SensoGate WA 130 H User Manual Retractable Fitting Return of Products Please contact our Service Team before returning a defective device. Ship the cleaned device to the address you have been given. If
More informationConductivity Measuring Sensor InduMax H CLS 52
Technical Information TI 167C/24/ae Conductivity Measuring Sensor InduMax H CLS 52 Electrodeless conductivity sensor with quick temperature measurement and hygienic design The CLS 52 sensors are intended
More informationInductive conductivity meter
Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct
More informationInductive conductivity meter
Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values
More informationCeramat WA 160(X) User Manual. Ceramic Sensor Lock-Gate
Ceramat WA 160(X) User Manual Ceramic Sensor Lock-Gate www.knick.de Warranty Defects occurring within 1 year from delivery date shall be remedied free of charge at our plant (carriage and insurance paid
More informationEXNER PROCESS EQUIPMENT
EXNER PROCESS EQUIPMENT EXTRACT Process retractable holder Technical information All brand and product names are trademarks of the company EXNER PROZESS EQUIPMENT Copyright notice Distributed by: EXNER
More informationAutomatic sensor lock-gate for extreme applications with ceramic sealing to the proces
Pneumatic Retractable Fittings Chem Energy Pharm Food Water Ceramat Sensor Lock-Gate Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces Unique lock-gate principle The
More informationMounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve
Type 3310/AT and Type 3310/3278 Pneumatic Control Valves Type 3310 Segmented Ball Valve Fig. 1 Type 3310/3278 with positioner Fig. 2 Type 3310/AT Mounting and Operating Instructions EB 8222 EN Edition
More informationINDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice
INDUCTIVE CONDUCTIVITY SENSOR Instruction Manual Bürkert 00 Subject to technical change without notice INTRODUCTION Table of Contents. INTRODUCTION.... Symbols used.... General safety instructions....
More informationReliable fluid detection with non-invasive ultrasonic measurement
Technical specification PIOX S502ID Reliable fluid detection with non-invasive ultrasonic measurement Permanently installed ultrasonic measuring system for the non-invasive detection of one of 2...5 fluids
More informationSCHOTT Instruments Process holders and accessories CHEMTRAC
SCHOTT Instruments Process holders and accessories CHEMTRAC Manual retractable process holder Technical information All brand and product names are trademarks of the company SI ANALYTICS GMBH Copyright
More informationJUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000
JUMO tecline Ci-S Inductive conductivity and temperature sensor for general process engineering Installation Instructions 20294200T94Z001K000 V1.00/EN/00582016 Contents Contents 1 Safety information................................................
More informationJUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering
Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid.
More informationWATERFLUX 3070 Quick Start
WATERFLUX 3070 Quick Start Battery powered electromagnetic water meter Electronic Revision ER 4.3.0_ up to ER 4.3.4_ (SW.REV 4.2.2_ up to 4.2.5_) KROHNE CONTENTS WATERFLUX 3070 1 Safety instructions 4
More informationMounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve
Type 3249-1 and Type 3249-7 Pneumatic Control Valves Type 3249 Aseptic Angle Valve Ball body version Special version with packing Type 3249-7 Control Valve with Type 3277 Actuator and integrated positioner
More informationMounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve
Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Type 3351 Pneumatic On/off Valve Version with handwheel Mounting and Operating Instructions EB 8039 EN Edition May 2016 Definition of signal
More information2/2- and 3/2-way solenoid valve for aggressive fluids
2/2- and 3/2-way solenoid valve for aggressive fluids Type 0121 can be combined with Direct-acting, media-separated valve with diameter of up to DN 8 Maintenance-free pivoted armature technology Vibration-proof,
More informationSeries 240 Type 3351 Pneumatic On/off Valve
Series 240 Type 3351 Pneumatic On/off Valve Application Shut-off valve with tight shut-off for liquids, gases and vapors according to DIN or ANSI standards Valve size DN 15 to 100 NPS ½ to 4 Pressure rating
More informationJUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering
Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid.
More informationCleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement
Technical Information Cleanfit W CPA450 Retractable assembly for 12 mm sensors for DO/pH/ORP measurement Application Pulp and paper industry Chemical industry Measurement in fibrous or coating media Tanks
More informationInline version with application-specific process adaptation
Pneumatic Retractable Fittings hem Energy Pharm Food Water eramat WA 50 Inline version with application-specific process adaptation Facts for extreme applications ceramic sealing to the process: extremely
More informationMounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321
Valve Series V2001 Globe Valve Type 3321 Fig. 1 Type 3321 Valve with mounted rod-type yoke for pneumatic or electric actuators (partial view) Mounting and Operating Instructions EB 8111/8112 EN Edition
More informationMounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil
Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Type 3535 Three-way Valve with bellows seal and rod-type yoke (partial view) Mounting and Operating Instructions EB 8135/8136 EN Edition
More informationConductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands
Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationMWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.
Industrial Temperature Assemblies measuring monitoring analysing MWD OO Meassuring range -200...+600ºC. OO Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic. OO Output: Resistance or analogue
More informationConductivity Measurement CLM 280
Technical Information TI 347C/07/en/07.03 51511754 Conductivity Measurement CLM 280 Battery-driven pocket meter for conductivity and resistance measurement Application CLM 280 is a compact pocket meter
More informationTIDALFLUX 2300 F Quick Start
Quick Start Electromagnetic flow sensor for partially filled pipes The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS
More information700 Series Anti-corrosion Control Valves
7 Series Anticorrosion Control Valves Specification Data CH92 11/97 Split Body PTFE Lined Control Valves for Corrosive Applications Table of Contents Foreword.................................................................
More information2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50
2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Safe
More informationDigital ph transmitter
Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings
More information2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50
2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Safe
More informationJUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor
Page 1/6 JUMO tecine CR-4P Conductive 4-Electrode Conductivity Brief description The JUMO tecine CR-4P fills the gap between conductive conductivity measurement with two-electrode conductivity sensors,
More informationGlass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases
Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,
More informationLined Butterfly Valve Pfeiffer Type BR 10a
Lined Butterfly Valve Pfeiffer Type BR 10a Application Tight closing, double eccentric butterfly valve with PTFE lining for process engineering and plants with industrial requirements, especially suitable
More informationType S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation
Type S030 INLINE fitting We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Operating Instructions Bedienungsanleitung
More informationCleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version
Technical Information Cleanfit P CPA472D Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version Application Chemical industry Power plants Plant design Tanks and process
More informationXMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.
Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others
More informationInstruction Manual. Model SC4A 19mm Conductivity Sensors. IM 12D7J4-E-E 6th edition YOKOGAWA
Instruction Manual Model SC4A 19mm Conductivity Sensors YOKOGAWA 6th edition TABLE OF CONTENTS 1. GENERAL... 1 1-1. Type number... 1 1-2. General specifications SC4A-AD... 1 1-3. General specifications
More informationDigital ph transmitter
Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings
More informationGEMÜ 539 esydrive Motorized globe valve
esydrive Motorized globe valve Features Linear or modified equal-percentage control characteristics High flow rates Force and speed are variably adjustable Extensive diagnostic facilities Operable via
More informationAutomated Globe Valves. BOA-H Mat P PN 16/25 DN Type Series Booklet
Automated Globe Valves BOA-H Mat P PN 16/25 DN 20-150 Type Series Booklet Legal information/copyright Type Series Booklet BOA-H Mat P All rights reserved. The contents provided herein must neither be distributed,
More informationSeries 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve
Series 240 Type 3347-1 and Type 3347-7 Pneumatic Control Valves Type 3347 Hygienic Angle Valve Application Control valve for hygienic applications in the food and pharmaceutical industries Valve size DN
More informationDiaphragm valve MV 309
Diaphragm valve MV 309 Nominal size DN 15 32 Nominal size 1/2 1 1/4 Pressure PN 6 bar Features pneumatic diaphragm valve DN 15 32 compact piston drive for medium pressure up to 6 bar (PTFE diaphragms)
More informationHigh-quality pressure sensor with mounted diaphragm seal With flange connection, flush diaphragm Model DSS27T
Pressure High-quality pressure sensor with mounted diaphragm seal With flange connection, flush diaphragm Model DSS27T WIKA data sheet DS 95.13 Applications For aggressive, highly viscous, crystallising
More informationDirect-acting 2/2- or 3/2-way pivoted armature valve
0330 Direct-acting 2/2- or 3/2-way pivoted armature valve Direct-acting, media-separated valve with diameter of up to DN 5 Maintenance-free pivoted armature technology Vibration-proof, block screwed coil
More informationSENSOFIT RET 5000 Technical Datasheet
SENSOFIT RET 5000 Technical Datasheet Manual retractable assembly Variable immersion length up to 700 mm With ball valve for easy sensor exchange without process interruptions Bayonet coupling for easy
More informationINSERTION Adaptor for analysis
INSERTION Adaptor for analysis Type can be combined with... Universal adaptor for type 8202 and 8222 ELEMENT s in pure, aggressive or contaminated liquids Adaptation into standard piping systems or conversion
More informationDeclaration of Conformity as per Directive 97/23/EC
Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany PTFE-lined Rotary plug valves Series 23e, with packing with lever for 90 operation with worm gear
More informationKM-165, KM-185, KM-200 OVERVIEW. Flow Monitor & Flow Indicator. Features. Operation
Flow Monitor & Flow Indicator KM-165, KM-185, KM-200 OVERVIEW Operation Float measuring principle Application Cooling systems and cooling circuits Mechanical engineering Pharmaceutical industry Chemical
More informationNAF-Setball ball sector valves DN , PN 10-40, ANSI Class
NAF-Setball ball sector valves DN 25-400, PN 10-40, ANSI Class 150-300 Fk 41.51(12)GB 4.98 Replaces Fk 41.51(1GB 12.97 Primary characteristics NAF-Setball is a ball sector valve with metal-to-metal or
More informationOPTIFLUX 2000 Quick Start
OPTIFLUX 2000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS OPTIFLUX 2000
More informationPraher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.
Praher S4 Ball Valve Lockable Handle Tagging Point Valve Bracket Actuation Materials Body - PVDF Ball Seat - PTFE Seals - FPM Sizes 3/8-4 /16mm - 110mm Features Lockable Handle (Lock not supplied) True
More informationPraher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.
Praher S4 Ball Valve Lockable Handle Tagging Point Valve Bracket Actuation Materials Body - PVDF Ball Seat - PTFE Seals - FPM Sizes 3/8" - 4"/16mm - 110mm Features Lockable Handle (Lock not supplied) True
More information2018 High Performance Check Valves for liquid and gaseous media
2018 High Performance Check Valves for liquid and gaseous media Check valves Catalogue 45 Date: 04/2018 WEH - We Engineer Hightech All rights reserved, WEH GmbH 2018. Unauthorized copies are strictly forbidden
More informationSeries 42 Self-operated Regulators. Type RS Check Valve (backflow protection)
Series 42 Self-operated Regulators Type 42-10 RS Check Valve (backflow protection) Application Designed to protect nitrogen and compressed air networks against backflow from directly connected systems.
More informationPressure relief valve DHV 718
Pressure relief valve DHV 78 Benefits diaphragm controlled pressure relief valve with piston guidance simple design, reliable function particularly suitable for oscillating pumps constant, frictionless
More informationPressure chlorine changeover unit C 7520
BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520
More informationOctave Water Meter Installation Manual
Octave Water Meter Installation Manual 1.0 Notes For proper flow measurements, the OCTAVE s measuring tube should be completely full at all times. Non-wetted sensors show loss of signal. Though this will
More informationSupplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478
Supplementary instructions Mounting accessories, pressure measurement technology Document ID: 78 Contents Contents About this document.... Function.... Target group.... Symbols used... For your safety....
More informationConductivity Measuring Cells ConduMax W CLS 19
Technical Information TI 110C/24/ae Conductivity Measuring Cells ConduMax W CLS 19 Two-electrode measuring sensors with cell constant k = 0.01/cm or k = 0.1/cm Area of application Measurement in pure and
More informationFlowCon SH mm. Adjustable Dynamic Self Balancing Valve SPECIFICATIONS
FlowCon SH 50-150mm Adjustable Dynamic Self Balancing Valve SPECIFICATIONS Pressure rating: 4000 kpa / 580 psi Temperature rating, media: -20 C to +120 C / -4 F to +248 F Material: - Diaphragm: Hydrogenated
More informationTitrette. class A precision. The next generation Digital Burette!
The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, you can titrate quickly and reliably with highest precision, even in
More informationSeries V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Control valves for heat transfer applications using organic media according to
More informationFlow. Oval Wheel Flowmeter Model DOE
Oval Wheel FIowmeter for low and high viscous liquids measuring monitoring analysing DOE Measuring range: 0.5 36 l/h und 1 40 l/min Viscosity range: 1 1000 cp Accuracy: ±1% of reading Material: stainless
More informationph-kompaktelektrodensystem sensopac CPA 320
Technische Information TI 0C/0/de ph-kompaktelektrodensystem sensopac CPA 0 One of the two reference systems is specially protected so that only the second monitoring reference system is affected by penetration
More informationEB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions
EB 8313-1 EN Translation of original instructions V2001-IP Control Valve Type 3372 0511/0531 Electropneumatic Actuator with Type 3321 Valve Type 3372 Electropneumatic Actuator Edition July 2013 Note on
More informationGEMÜ 549 esydrive Motorized globe valve
esydrive Motorized globe valve Features Linear or modified equal-percentage control characteristics High flow rates Force and speed are variably adjustable Extensive diagnostic facilities Operable via
More informationFlowmeter, Plastic 805 / 807 / 815 / / 825 / 832 / 835. Sectional drawing
Flowmeter, Plastic Construction The flowmeter operates according to the variable area principle. Metering tubes are available in TrogamidT, suitable for inert media, and polysulfone, suitable for corrosive*
More informationGEMÜ R680 Motorized diaphragm valve
Motorized diaphragm valve Features Standard integral optical position indicator Optional flow direction and installation position Insensitive to particulate media Motorized alternative for applications
More informationSeries V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator ANSI version Application Mixing or diverting valves for heat transfer applications using organic
More informationSeries V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Mixing or diverting valves for heat transfer applications using organic media
More informationOperating Instructions Dipfit CPA111
BA00112C/07/EN/13.15 71297906 Products Solutions Services Operating Instructions Dipfit CPA111 Immersion and installation assembly for ph/orp measurement Table of contents Dipfit CPA111 Table of contents
More informationOperating Instructions Flexdip CYA112
BA00432C/07/EN/13.13 71207066 Products Solutions Services Operating Instructions Wastewater assembly About this document Safety messages The structure, signal words and safety colors of the signs comply
More informationLevel Measurement Point level measurement - RF Capacitance switches
Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable
More informationTechnical Information Cleanfit CPA472D
TI00403C/07/EN/13.13 71227170 Products Solutions Services Technical Information Cleanfit CPA472D Retractable process assembly for ph and ORP sensors Heavy duty version Application Chemical industry Biodiesel
More informationCompact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:
Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation
More informationINSERTION flow sensor for continuous flow measurement
INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)
More informationPneumatic Butterfly Valve Pfeiffer Type BR 14b/AT
Pneumatic Butterfly Valve Pfeiffer Type BR 14b/AT Application Tight closing, double eccentric butterfly valve for process engineering and plants with industrial requirements Nominal size DN 80 to DN 400
More informationType 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies
Type 0283, 0293 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 The operating instructions...2 2 Intended
More informationN E W! The next generation Digital Burette.
N E W! Bottle-top Burette Easy dropwise titration, a compact, highprecision design, replaceable piston/cylinder assembly and an optional PC interface these are just some of the features of this successor
More informationMounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve
Series V2001 Valves Type 3321 Globe Valve Type 3321 Globe Valve with rod-type yoke and Type 3372 Electropneumatic Actuator (350 cm²) Mounting and Operating Instructions EB 8111/8112 EN Edition June 2013
More informationFlowmeter, Plastic 855 / 857 / 865 / / 875 / 880 / 885
Flowmeter, Plastic Construction The flowmeter operates according to the variable area principle. Metering tubes are available in TrogamidT, suitable for inert media, and, suitable for corrosive* media
More informationCleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions
Technical Information Cleanfit H CPA475 Retractable assembly for ph, ORP measurement under sterile conditions Application Food industry Beverage industry Pharmaceutical industry Drinking water The retractable
More informationThermowell for temperature sensors omnigrad M TW 13
Technical information TI 264T/02/en 60019743 Thermowell for temperature sensors omnigrad M TW 13 Pipe thermowell Flanged process connection Omnigrad M TW 13 thermowells are designed for the use in the
More informationCable thermocouple Model TC40
Electrical temperature measurement Cable thermocouple Model TC40 WIKA data sheet TE 65.40 for further approvals see page 11 Applications For direct installation into the process Machine building Motors
More informationPoint level measurement Capacitance switches
Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.
More informationProbe holders for analytical probes
Probe holders for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation
Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating
More informationTitrette. class A precision. 10 ml. New. size. The next generation Digital Burette!
The next generation Digital Burette! Titrette class A precision F I R S T C L A S S B R A N D With the Titrette bottle-top burette, available in 10, 25, and 50 sizes, you can titrate quickly and reliably
More information2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65
2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, 10-65 Suitable for aggressive media High flow rate value -piece Actuator with adjustable limit switches 2-piece Visual position
More informationMounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves
Series 250 Type 3252 1 and Type 3252 7 Pneumatic Control Valves Type 3252 High-pressure valve with Type 3277 Pneumatic Actuator and Type 3767 Electropneumatic Positioner Mounting and Operating Instructions
More informationPressure transducer DMU 01K Compact version
Pressure transducer DMU 01K Compact version Dimensions (in mm) Wiring diagram 8 Application Special OEM unit. For electronic pressure measurement in industrial or HVAC applications (such as hydraulic,
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies
Type 6027 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation
Globe control valve, pneumatically operated Actuator sizes 40 mm - 125 mm, Nominal diameter DN10-65 Kolbengesteuertes Geradsitzventil Antriebsgrößen 40 mm - 125 mm, Nennweiten DN10-65 Vanne à siège droit
More informationOperating Instructions (from serial number 3000)
Conductivity meter Leitfähigkeits-Messgerät Conductivimètre Operating Instructions (from serial number 3000) Bedienungsanleitung (ab Serien-Nummer 3000) Manuel d utilisation (à partir du numéro de série
More informationMounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator
Pneumatic Control Valve Type 3510-1 and Type 3510-7 Type 3510-1 with 120 cm 2 actuator Type 3510-7 with 120 cm 2 actuator and integrated positioner Type 3510-1 with 60 cm 2 actuator Fig. 1 Pneumatic control
More information