FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS

Size: px
Start display at page:

Download "FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS"

Transcription

1 Before installation these instructions must be fully read and understood INTRODUCTION Actuator or Counterweight assisted, flanged or welded ends. This manual provides guidelines to be observed for the following operations: storage installation into the pipeline maintenance preservation The manual is intended for the following personnel/staff: plant warehouse staff installers maintenance engineers In addition to the instructions in this manual, specific plant safety regulations must always be followed. Before starting any maintenance activity, it is strongly recommended to read carefully and completely this manual. It is also recommended to verify the availability of the suggested spare parts, so you can always assemble the valve and minimize intervention time. For installation and maintenance operations no specific equipment or tools are required, other than those usually available in the plant. Do not use the valve as an interception valve for cleaning the line. Maximum admitted velocity for fluids: 6m/s for liquids 80m/s for gas or steam/vapour VERIFICATION UPON RECEIPT AND STORAGE Before start-up: On arrival of materials, it is recommended to: - Check the integrity of the case/packing. - Open the case and verify that there is no damage due to transportation. - Do not open the barrier bag - if any. - Verify that the content matches the packing list. - Store the valves in their original packing (unless damaged). When doing so, please observe the following: - Store the valves in a closed, clean and dry storage room. - Do not place the packages directly on the ground. - Check the packages every two months. - Substitute the silica gel every six months (not applicable in the case of barrier bag). For actuated valves, in addition to the above, please refer to the actuator manual. Emerson is always at the customer s disposal for further technical information. Emerson.com/FinalControl 2017 Emerson. All Rights Reserved. VCIOM EN 17/11

2 HANDLING During handling operations, valves must be lifted and handled as indicated in Fig. 1 by using lifting equipment respecting the carrying limits (valve weight indicated in the drawings). Optional eyebolts on the valve body can be used to lift the valve. Do not use any lifting equipment that is either damaged or/and of an inadequate/unknown size. Do not use the eyebolt in the bonnet to lift the valve. INSTALLATION For correct operation of the valve, this must be installed in horizontal position only as indicated in Fig. 2. Different positions from those indicated may cause non-correct valve operation and/or quick deterioration of the valve. The following operations must be performed only immediately before the installation: 1. Remove the protection caps of the end faces. 2. Remove pin protection. 3. Check the pipeline sections upstream and downstream. Make sure that there are no solid particles or any other kind of dirt or debris inside. If necessary, clean carefully by using an air line. 4. Verify the flow direction in the line. Verify that the direction of the line corresponds to the flow direction indicated by the arrow on the valve body. Make sure that the materials of construction listed on the valve nameplates (service and temperature), are appropriate for the service and fluid of the plant. Flanged valves Place the valve between the two pipe flanges, and the gasket between the valve s flange and the pipe s flange. Make sure that it is positioned in the center. Assemble the valve to the pipe by tightening the bolts according to the torques given by the Engineering Company that designed the plant. Drain connection Draining connection in the valve body (Fig.4) to be connected to plant draining system before putting valve in operation. In case of lack of draining, condensate retained in the valve bottom could flash generating pressure peaks which may damage the valve and/or other equipments in the plant. Protect eyes with appropriate welding masks or goggles during all welding operations. General notes Should one end not be connected to the line for longer than half a day, the open end must be properly closed and sealed in order to prevent entry of dirt or debris. After the installation of the valve and before the line testing, it is strongly recommend cleaning the line in order to remove dirt and/or foreign bodies that may damage the tightness between the seat and the disc, and the correct operation of the valve. We strongly recommend checking the torque of the body-bonnet bolts, especially if the valve is to operate at high temperatures. Tightening must be done alternatively on the bolts that are diametrically opposed, see Fig. 3. The torque values are those reported in Table 3. FIGURE 1 - VALVE LIFTING AND HANDLING FIGURE 2 - POSITION FOR VALVE INSTALLATION 2 max 2 max Flow 2 max FIGURE 3 - TIGHTEN BOLTS - FLANGE TIGHTENING SEQUENCE 2 max FIGURE 4 - CONNECTION FOR DRAINING Butt-welding valves Position the valve and verify its alignment with the pipe. Proceed with the welding in accordance with the procedure indicated by the Engineering Company that designed the plant. Usually, the first weld layer will be made with TIG, while following weld layers will be made with the appropriate electrode for the valve body material. Drain in G position 2

3 START UP REQUIREMENTS Before the start up of the plant, we recommend to: Check that the lines have been accurately cleaned. If the valve has been stocked for a long time and should operate at high temperatures, verify the tightness of the body/bonnet bolts. Tightening must be done alternatively on the bolts that are diametrically opposed. See Fig. 3. The torque values are those reported in Table 3. Check the tightness of the gland bolts. Check that the pin s protection has been removed. Check electrical, pneumatic and hydraulic connection - if any. Check that the drain in the valve body is properly connected to the plant draining system. Check that the actuator is properly installed according to section 8. Check that the torque/travel switches are properly set according to actuator maintenance manual. Preventive Check the space between the gland and the bonnets every 12 months. In case of a reduction of the space, restore the space by installing a new ring packing. Remove the bonnet of the valve every 4 years. Check the inside and verify that the valve is not damaged, especially the disc pin and the bushes. Re-lap the seats if necessary and replace the body/bonnet gasket and the packing. After 4 years operation, replace bushes 108 and 126. Disassemble the valve every 8 years. Recondition the seats, replace the bushes, the anti-clutch spacer, the gasket, the packing and the keys. It is recommended having a pin available during the operation. For the actuator, proceed as indicated in its maintenance manual. An incorrect connection of the actuator is dangerous and may cause irreversible damages to the valve. During the start-up of the plant, verify the packing seal. In case of leakage, tighten the bolts alternatively. During the start-up, for the valves equipped with lever and external counterweight, make sure the counterweights are in the right position for the intended service. Under regular service conditions, operate the lever in the sense of close position. When discharged the lever should return by itself to its former position. Without fluid in the valve, the disc shall position itself in the close position. The actuator should be energized before the start up of the plant, in order to avoid damages to the valve, and to minimize drops of charge, maximizing the performance of the plant. SCHEDULED MAINTENANCE Routine inspections Monthly check that there is no leakage from the body/bonnet area. In case of leakage from the body/bonnet area, tighten the appropriate the bolts according to the sequence in Fig. 3. In addition to the above, please refer to the actuator manual. 3

4 TROUBLESHOOTING GUIDE Problems reported are not exhaustive, they represent the most frequent ones. Leakage from the packing In case of leakages from the packing that cannot be stopped by tightening the gland bolts, proceed as follows. Packing may have hardened. In this case, it must be replaced. The distance between the gland and the bonnet is reduced. Thus, the packing cannot be compressed. Packing must be replaced. Scratches or other marks are found on the pin or the pin itself is bent. In these cases, the pin must be replaced. The gland may be jammed on the pin because of a non-uniform tightness of the gland bolts. Loosen the gland bolts. Move the gland and set it again; then tighten the bolts progressively and uniformly. Leakage from the body/bonnet joint A leakage from the body/bonnet joint may be the consequence of a long storage time of the valve. The gasket may have lost elasticity and/ or the bolts may have loosened. In the first case, the leakage will progressively decrease, the gasket regaining part of its elasticity with the contact of the process fluid. A verification of the bolts tightness will contribute to stop the leakage. In the second case, bolts should be tightened according to Fig. 3. Usually these two actions are combined. Leakage under operation of the plant requires the tightening of the bolts and the replacement of the gasket as soon as possible. Leakage between seat and disc In case of leakage between seat and disc, check that: No foreign material is locked between seat and disc, scratching the sealing surfaces. No foreign material is laid down between the seats, preventing the disc from closing. During a previous closure the fluid has laminated the seal surfaces, eroding these. For all the above cases it is absolutely necessary to disassemble the valve as soon as possible and perform an inspection of the internal parts in order to reduce further damage. Jamming of valve along the stroke If a higher torque is required at some points when opening/closing the valve, proceed as follows: Disassemble the valve, as body guides and disc may start to seize. Problems regarding motor operation Please, refer to the actuator instruction manual. DISASSEMBLING INSTRUCTIONS Here below are the procedures to follow to disassemble valves. Before starting any operation, it is important to: identify the problem clean the area around the valve that is to be disassembled prepare a box and/or a pallet where to collect all pieces prepare a polyethylene sheet to protect all components and to prevent particles from entering the body of the valve. During disassembling operations, identify all pieces to keep track of the position/orientation of the parts regarding the valve body. Actuator disassembling 1. Hold the actuator using the eyebolts with a strip suitable to its weight. 2. Remove the bolts (79) that join the actuator and the valve s flange together 3. Remove the actuator from the pin of the valve. If necessary use a lever between the valve and the flange of the actuator. Before starting disassembling any part of the valve it is very important to verify - for your safety - that: the line is not pressurized the valve is not in temperature all electrical, pneumatic and/or hydraulic devices have been switched off and disconnected. Counterweight disassembling 1. Hook the counterweight s opening protection structure (276) with a steel thread. 2. Remove the bolts that close the protection of the counterweight and the opening itself. 3. Hold the counterweight s lever (107) with a strip. Then remove the blocking nut (115) and the washer (211). 4. Hold the strip tight and remove the counterweight. If necessary use a lever. 4

5 Disassembling of the disc 1. In order to remove the disc, the actuator and the counterweight have to be previously removed. 2. Remove the bolts between the body and the bonnet (11). Place them in a clean space. 3. Lift the bonnet (6) by means of a strip and a hoist and hold it to the eyebolt. 4. Hold the hinge pin and the disc together (45-3). Place the strip between the hinge pin and the disc and hold it by means of a hoist. 5. Remove the gland bolts (16), the gland flange (10), and the gland (9) from the side of the actuator and from the side of the counterweight (if existing). 6. Remove the packing by means of an iron hook-shaped thread. 7. Remove the pin (49) always from the side from which the actuator was installed. During this operation, the spacer (65) will be removed and saved for reassembling. 8. Remove the hinge pin/disc from the valve. Removal of valves welded to the line Shall the valve need to be removed from the line, cut the pipe far from the welding point so that the valve s gauge can be restored. The packing assembling must be done without pressure in the valve and in the line. ASSEMBLING INSTRUCTIONS Before starting reassembling is recommended to verify the following points: Remove any dirt or particles with a wire brush or abrasive cloth; remove any oil or grease with a suitable solvent, to avoid damage caused by foreign particles - in particular on the sealing area. Never re-use the old gaskets, even though they seem to be in good condition. During reassembling operations, match the punched pieces so that they are correctly assembled. Packing assembling 1. Remove gland nuts (16) and bolts (15). 2. Lift the gland flange (10) and the gland (9). 3. Remove the used packing by means of a steel hook-shaped thread. 4. For a better sealing, carefully clean the packing room and the shaft. Make sure that they are not damaged (scratches) and there are not seizing signs. 5. The packing assembly must be done by placing, in the packing room, one ring at a time. Be careful to allocate them correctly and press them to the bottom of the packing room. 6. Once the packing room is full, replace the gland (9) and the gland flange (10) to their original positions. 7. Tighten the gland bolts gradually and uniformly, the torque valves can be calculated according to table 4. For some alternative days, especially during start up, re-tighten the bolts in order to repristine the loosening of the gland. Body/bonnet gasket replacement 1. Before replacing the body/bonnet gasket, clean the body/bonnet flange s surfaces carefully. 2. Fit the gasket in the seat, then align in a parallel position the bonnet flange with the flange in which the gasket is placed. Do not use the bolts to align. 3. While tightening, make sure that the flange s pairing is completely parallel. 4. Tighten the bolts according to fig.3. In the first tightening be careful to apply 1/4 of the final torque reported in Table 3. For a better performance of the joint, tight again all bolts once the installation is started up. Actuator assembling Valve without counterweight 1. Check that the key on the valve pin is oriented vertically upwards (Fig. 5.A). 2. Insert the coupling on the valve pin checking that the housing for actuator square shaped pin is positioned horizontally (Fig. 5.B). 3. Fix the actuator to the valve flange through the bolts checking that the square shaped pin is properly inserted into the coupling. FIGURE 5.A Key on the valve pin to be oriented vertically upwards FIGURE 5.B Housing for actuator pin in the coupling to be positioned horizontally 5

6 Valve with counterweight 1. Check that the key on the valve pin is oriented 45 downwards facing the valve outlet (Fig. 6.A). 2. Insert the coupling on the valve pin checking so that the housing for actuator square shaped pin is positioned horizontally (Fig. 6.B). 3. Fix the actuator to the valve flange through the bolts checking that the square shaped pin is properly inserted into the coupling. PRESERVATION IN THE PLANT FIGURE 6.A Valve inlet For a correct preservation of the valve in the plant, once the lines have been cleaned up, follow the instructions below. Key to be oriented 45 downwards facing the valve outlet 1. Fill in the valve with inert gas (azote), 2 bar. 2. Verify that the pin is covered with a layer of grease. FIGURE 6.B For the actuator, please refer to the instructions below and the actuator s manual: 1. Replace the plastic cap with an adapted cap, able to guarantee the sealing from water. 2. When necessary, connect by means of suitable plug-cable (minimum IP55), the resistance anti-condensation as indicated in the electrical scheme in the electrical junction box. 3. Check the general conditions of the valve and the actuator once a year. SPARE PARTS LIST Emerson guarantees the supply of all spare parts for a period of at least ten years from the manufacturing date (month/year) indicated on the tag plate. Housing for actuator pin in the coupling to be positioned horizontally The suggested spare parts and the correlative quantity is reported in the table below and refer to the typical designs attachment. Spare part Description Percentage [1] Minimum quantity 2 Seat 5% 1 set 3 Disc 5% 1 49 Pin 5% 1 5 / 52 Gasket 20% 2 8 Packing 20% 2 sets 108 / 126 Bush 5% 1 set 60 / 330 / 241 Key 10% 1 1. The percentage must be calculated on the base of equal valves and round off to the unit 6

7 ATTACHMENTS The reference designs are those supplied with the valve. The designs below are just a typical sample and cannot be considered for further purposes. FIGURE 7 - Swing Check valve bolted bonnet ASME Class Welding ends - Assisted pneumatically on the right side SECTION A - A (not in scale) 11/12 'Y' / A A /16/ Detail Y TABLE 1 - PARTS LIST No. Description 1 Body 2 Seat 3 Disc 5 Gasket 6 Bonnet 8 Packing 9 Gland 10 Gland flange 11 Body bolts 12 Body nuts 15 Gland bolt 16 Gland nut No. Description No. Description 17 Washer 77 Actuator 23 Name plate 78 Disc washer 45 Hinge 79 Stud/Screw 47 Disc bolts and nuts 108 Anti-friction bush 49 Pin 126 Anti-friction bush 50 Stud 279 Bottom ring 51 Nut 309 Spacer 52 Pin gasket 328 Bush 55 Pin cover 330 Key 60 Key 331 Coupling actuator-pin 64 Split pin 65 Spacer 7

8 FIGURE 8 - Swing check valve bolted bonnet ASME Class Welding ends - Pneumatically assisted on the left side and with counterweight 11/12 'Y' SECTION A - A (not in scale) A B / /16/17 45 Detail Y Close position Open position 77 TABLE 2 - PARTS LIST No. Description 1 Body 2 Seat 3 Disc 5 Gasket 6 Bonnet 8 Packing 9 Gland 10 Gland flange 11 Body bolts 12 Body nuts 15 Gland bolt 16 Gland nut 17 Washer 23 Name plate No. Description No. Description 45 Hinge 115 Nut 47 Disc bolts and nuts 126 Bush 49 Pin 132 Screw 50 Stud 133 Top screw 51 Nut 211 Washer 55 Pin cover 241 Key 60 Key 276 Counterweight protection 64 Split pin 279 Bottom ring 65 Spacer 309 Spacer 77 Actuator 330 Key 78 Disc washer 331 Coupling actuator-pin 79 Stud/Screw 107 Lever 108 Bush 8

9 ACTUATOR OR COUNTERWEIGHT ASSISTED, FLANGED OR WELDED ENDS TABLE 3 - BODY/BONNET BOLTS TORQUE Bolts: A 193 B7 / A 193 B16 Torque values Torque values Bolts: A 193 B8 Torque values Ø Bolts Kgm (Nm) Ø Bolts Kgm (Nm) Ø Bolts Kgm (Nm) Ø Bolts Kgm (Nm) ½ 9 (90) 1¾ 426 (4178) ½ 3 (26) 1¾ 122 (1194) ⅝ 18 (175) 1⅞ 527 (5165) ⅝ 5 (50) 1⅞ 150 (1476) ¾ 31 (305) (6297) ¾ 9 (87) (1799) ⅞ 50 (487) 2¼ 921 (9030) ⅞ 14 (139) 2¼ 263 (2580) 1 74 (725) 2½ 1271 (12460) 1 21 (207) 2½ 363 (3560) 1⅛ 107 (1050) 2¾ 1537 (15076) 1⅛ 31 (300) 2¾ 439 (4307) 1¼ 149 (1462) (19648) 1¼ 43 (418) (5614) 1⅜ 201 (1968) 3¼ 2556 (25062) 1⅜ 57 (562) 3¼ 730 (7161) 1½ 263 (2579) 3½ 3201 (31387) 1½ 75 (737) 3½ 914 (8968) 1⅝ 339 (3325) 1⅝ 97 (950) Torque values TABLE 4 - CONSTANT FOR CALCULATION OF PACKING TORQUES Shaft Gland bolts diameter dia. ⅛ ¼ ⅜ ½ ⅝ ¾ ⅞ 1 1⅛ 1¼ 1⅜ 1½ 1⅝ 1¾ 1⅞ 2 2¼ 2½ 2¾ NOTES 1. Select the constant in relation to stem diameter and packing bolts size. 2. To obtain the packing bolts torque in Nm please multiply the selected constant for pressure in MPa. Valve under pressure of 2MPa with stem diameter equal to 44.5 mm and packing bolts size equal to ⅝ inches: a. Constant is equal to 7.5 b. Packing bolts torque is equal to 7.5*2= 15 Nm 9

10 Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fasani is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson.com/FinalControl

KTM Hindle Series 300 Ultra-Seal two piece metal seated ball valves Installation and Maintenance Instructions

KTM Hindle Series 300 Ultra-Seal two piece metal seated ball valves Installation and Maintenance Instructions Before installation these instructions must be fully read and understood Warning For safety reasons, it is important to take the following precautions before you start work on the valve: 1. Personnel making

More information

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Keystone Butterfly valves ParaSeal Installation and maintenance instructions Before installation these instructions must be fully read and understood Please read these instructions carefully Hazard potentials: disregarding of instructions improper use of product insufficiently

More information

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions Before installation these instructions must be fully read and understood Potentially dangerous practices: disregarding instructions improper use of product use of insufficiently qualified personnel Application

More information

Fisher TBX Hydro Plug Fixture

Fisher TBX Hydro Plug Fixture Instruction Manual TBX Hydro-Plug Fixture Fisher TBX Hydro Plug Fixture Contents Introduction... 1 Scope of Manual... 1 Description... 2 Educational Services... 2 Principle of Operation... 2 Maintenance...

More information

Before installation these instructions must be fully read and understood

Before installation these instructions must be fully read and understood Before installation these instructions must be fully read and understood Yoke bushing Split gland bushing One-piece body with accessible internals Gland Swing bolts Fully retractable stellite disc Figure

More information

Fisher CVX Hydro Plug Fixture

Fisher CVX Hydro Plug Fixture Instruction Manual CVX Hydro-Plug Fixture Fisher CVX Hydro Plug Fixture Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 2 Principle of Operation... 2 Maintenance...

More information

Anderson Greenwood Single Active SSV Installation and Maintenance Instructions

Anderson Greenwood Single Active SSV Installation and Maintenance Instructions Before installation these instructions must be fully read and understood The intent of these instructions is to acquaint the user with the storage, installation and operation of this product. Please read

More information

Fisher 644 and 645 Differential Pressure Pump Governors

Fisher 644 and 645 Differential Pressure Pump Governors Instruction Manual 644 and 645 Pump Governors Fisher 644 and 645 Differential Pressure Pump Governors Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services...

More information

Sempell High Pressure Stop Valves Model VA500 (DIN)

Sempell High Pressure Stop Valves Model VA500 (DIN) Designed for the isolation and control of high temperature and high pressure systems, this multipurpose globe valve can be used in a wide variety of applications. Features Type tested (except for material

More information

HANCOCK 600 GATE, GLOBE AND CHECK VALVES FORGED STEEL

HANCOCK 600 GATE, GLOBE AND CHECK VALVES FORGED STEEL HANCOCK 600 GATE, GLOBE AND CHECK VALVES A range of ASME class 800 and 1500 reduced bore forged steel valves with screwed, socket weld, butt weld or flanged ends GATE VALVES A compact but extremely sturdy

More information

KEYSTONE FIGURE 79 PNEUMATIC ACTUATOR OPERATING AND MAINTENANCE INSTRUCTIONS

KEYSTONE FIGURE 79 PNEUMATIC ACTUATOR OPERATING AND MAINTENANCE INSTRUCTIONS Operating and Maintenance Instructions for: Figure 79 Pneumatic Actuators (U/E options) Double Acting Actuator 4. If pipelines are hydraulically tested, then the lines should be blown down with high pressure

More information

Fisher 3024C Diaphragm Actuator

Fisher 3024C Diaphragm Actuator Instruction Manual 3024C Actuator Fisher 3024C Diaphragm Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 3 Installation... 5 Mounting the Actuator on the Valve...

More information

SEMPELL HIGH PRESSURE CHECK VALVE MODEL VR500 (ASME)

SEMPELL HIGH PRESSURE CHECK VALVE MODEL VR500 (ASME) Designed for use in high temperature and high pressure systems wherever a reverse flow has to be avoided. FEATURES Piston type check valve Body made of forged steel Wear resistant stellite body seat Separated

More information

Baumann Sanitary Diaphragm Angle & In-Line Control Valve Instructions

Baumann Sanitary Diaphragm Angle & In-Line Control Valve Instructions Instruction Manual D103370X012 84000 Control Valve Baumann 84000 Sanitary Diaphragm Angle & In-Line Control Valve Instructions CONTENTS Introduction...1 Scope...1 Safety P recautions...1 Maintenance...2

More information

Baumann Mikroseal Control Valve

Baumann Mikroseal Control Valve Instruction Manual 81000 Valve Baumann 81000 Mikroseal Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 3 Installation... 3 Air Piping... 4 Flow Direction...

More information

Baumann Sanitary Diaphragm Angle and Inline Control Valve

Baumann Sanitary Diaphragm Angle and Inline Control Valve Instruction Manual 84000 Valve Baumann 84000 Sanitary Diaphragm Angle and Inline Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Flow Direction...

More information

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc. TREATER VALVE All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed

More information

Fisher 656 Diaphragm Actuator

Fisher 656 Diaphragm Actuator Instruction Manual 656 Actuator Fisher 656 Diaphragm Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 1 Principle of Operation... 2 Specifications... 2 Maximum Pressure Limitations...

More information

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions Instruction Manual D103356X012 24000C Control Valve Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions CONTENTS Introduction...1 Scope...1 Safety Precautions...1 Maintenance...2 Flow

More information

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES 12501 Telecom Drive, Tampa, FL 33637 Ph: (813) 978-1000 Fax: (813) 977-3329 www.cpc-cryolab.com INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS 17/4.5.2 Rev. 0 2001 SERIES CRYOGENIC BAR STOCK BODY

More information

DVG/AF Variable Geometry Desuperheater

DVG/AF Variable Geometry Desuperheater Instruction Manual D101616X012 DVG/AF Desuperheater DVG/AF Variable Geometry Desuperheater Contents Introduction............................... 1 Scope of Manual.......................... 1 Description...............................

More information

TECHNICAL MANUAL MT029

TECHNICAL MANUAL MT029 Ed.2008 Rev.B REFLUX 919 TECHNICAL MANUAL MT029 INSTALLATION, COMMISSIONING AND MAINTENANCE ISTRUCTIONS TABLE OF CONTENTS Chapter Page 1. AIM 4 2. DESCRIPTION OF THE VALVE 4 3. IDENTIFICATION OF THE VALVE

More information

Fisher D2T FloPro Control Valve

Fisher D2T FloPro Control Valve Instruction Manual D2T FloPro Valve Fisher D2T FloPro Control Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 2 Specifications... 3 Installation... 3 Setting

More information

Type 644 and 645 Differential Pressure Pump Governors

Type 644 and 645 Differential Pressure Pump Governors Instruction Manual 644 and 645 Pump Governors Type 644 and 645 Differential Pressure Pump Governors Introduction Scope of Manual This instruction manual provides information on installation, adjustment,

More information

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED DIAPHRAGM BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to

More information

6SC SERIES MODELS 910F, 910FLW, 920F IRON SWING CHECK VALVE INSTALLATION OPERATION MAINTENANCE GUIDE

6SC SERIES MODELS 910F, 910FLW, 920F IRON SWING CHECK VALVE INSTALLATION OPERATION MAINTENANCE GUIDE 6SC SERIES MODELS 910F, 910FLW, 920F IRON SWING CHECK VALVE INSTALLATION OPERATION MAINTENANCE GUIDE DOCUMENT NO.: ES-1495 REVISION LEVEL: A ISSUED BY: Bill Hooks DATE: 09/25/13 APPROVED BY: DATE: APOLLO

More information

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 ) I & M Mark 8 Series 0 Wasson Road Cincinnati, OH 4509 USA Phone 5-5-5600 Fax 5-8-005 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark 8 Control Valves (-/ - ) Warning:

More information

Operating & Maintenance Manual For Steam Conditioning Valve

Operating & Maintenance Manual For Steam Conditioning Valve For Steam Conditioning Valve 1 Table of Contents 1.0 Introduction 3 2.0 Product description 3 3.0 Safety Instruction 4 4.0 Installation and Commissioning 5 5.0 Valve Disassembly 6 6.0 Maintenance 6 7.0

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

HIGH PRESSURE CONTROL VALVE PISTON BALANCED PISTON BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be

More information

Baumann Way Control Valve

Baumann Way Control Valve Instruction Manual 24003 Valve Baumann 24003 3-Way Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Educational Services... 3 Maintenance... 3 Installation... 3 Air

More information

Baumann Sanitary Angle Control Valve

Baumann Sanitary Angle Control Valve Baumann 83000 Sanitary Angle Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Educational Services... 2 Maintenance... 3 Installation... 3 Air Piping... 4 Flow Direction...

More information

Fisher 2052 Diaphragm Rotary Actuator

Fisher 2052 Diaphragm Rotary Actuator Instruction Manual 2052 Actuator Fisher 2052 Diaphragm Rotary Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 4 Installation... 4 Actuator Mounting and Changing

More information

K-LOK Installation, Operation, Maintenance and Troubleshooting

K-LOK Installation, Operation, Maintenance and Troubleshooting K-LOK Installation, Operation, Maintenance and Troubleshooting General Suggested installation orientation is with valve shaft horizontal or inclined from vertical. Unless otherwise recommended by Tyco

More information

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood HAZARD POTENTIALS disregarding of instructions improper use of product insufficiently qualified personnel Valve application to be

More information

Baumann Series Flexsleev Control Valve Instructions

Baumann Series Flexsleev Control Valve Instructions Instruction Baumann 86000 Series Instructions Baumann 86000 Series Flexsleev Control Valve Instructions Contents Introduction...1 Scope...1 Safety Precautions...1 Maintenance...2 Installation...3 Air Piping...3

More information

EC4 SERIES CRYOGENIC VALVES 1/4 2 Sizes

EC4 SERIES CRYOGENIC VALVES 1/4 2 Sizes 12501 Telecom Drive, Tampa, FL 33637 Ph: (813) 978-1000 Fax: (813) 977-3329 www.cpc-cryolab.com INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS 17/2.5.6 Rev. 0 EC4 SERIES CRYOGENIC VALVES 1/4 2 Sizes

More information

Fisher RSS Lined Globe Valve

Fisher RSS Lined Globe Valve Instruction Manual D0990 RSS Valve July 07 Fisher RSS Lined Globe Valve Contents Introduction... Scope of Manual... Description... Educational Services... Specifications... Installation... Maintenance...

More information

Baumann 24000F Wafer Control Valve

Baumann 24000F Wafer Control Valve Instruction Manual 24000F Valves Baumann 24000F Wafer Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Installation... 3 Air Piping... 3 Disassembly...

More information

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Valve Instructions

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Valve Instructions Instruction Manual D103360X012 24000CVF/SVF Control Valve Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Valve Instructions CONTENTS Introduction...1 Scope of Manual...1 Safety Precautions...1-2

More information

Fisher 657 Diaphragm Actuator Sizes and 87

Fisher 657 Diaphragm Actuator Sizes and 87 Instruction Manual 657 Actuator (30-70 and 87) Fisher 657 Diaphragm Actuator Sizes 30 70 and 87 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Mounting

More information

Keystone Figure 85/86 Check valves Installation and Maintenance Instructions

Keystone Figure 85/86 Check valves Installation and Maintenance Instructions Please read these instructions carefully 1.3 Handling 1.3.1 Packed valves Lifting and handling of the packed valves in crates should be carried out by appropriate lifting equipment. If a fork lift truck

More information

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves Installation, Operation, Maintenance Instructions Split Body Valves with Bellows Seal Series 025 300 Globe Valves Series 027 300 Angle Valves Series 028 300 3-Way-Valves 1 GENERAL INFORMATION These instructions

More information

Double Offset High Performance Butterfly Valve

Double Offset High Performance Butterfly Valve Double Offset High Performance Butterfly Valve INSTALLATION OPERATION MAINTENANCE APOLLO INTERNATIONAL HIGH PERFORMANCE BFV IOM - Page 2 of 20 TABLE OF CONTENTS INTRODUCTION 3 PRODUCT STORAGE 3 PRODUCT

More information

Fisher CAV4 Control Valve

Fisher CAV4 Control Valve CAV Valve Product Bulletin Fisher CAV Control Valve The Fisher CAV control valve with Cavitrol IV trim is designed specifically for liquid applications, such as boiler feedwater recirculation, where pressure

More information

Fisher RSS Lined Globe Valve

Fisher RSS Lined Globe Valve Instruction Manual D0990 November 009 RSS Valve Fisher RSS Lined Globe Valve Contents Introduction............................... Scope of Manual.......................... Description...............................

More information

Fisher D4 Control Valve Assembly

Fisher D4 Control Valve Assembly Fisher D4 Control Valve Assembly Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services... 2 Installation... 4 Spring Adjustment... 5 Maintenance... 6

More information

Baumann Pneumatic Actuators

Baumann Pneumatic Actuators Instruction Manual Baumann Pneumatic Actuators Baumann Pneumatic Actuators Contents Introduction... 1 Scope of Manual... 1 Design Notes... 2 Installation... 2 Attaching an Air-to-Retract (ATR) Actuator

More information

Fisher Vee-Ball V150 and V300 NPS 14 through 24x20 Rotary Control Valves

Fisher Vee-Ball V150 and V300 NPS 14 through 24x20 Rotary Control Valves Instruction Manual V150 and V300 Valves Fisher Vee-Ball V150 and V300 NPS 14 through 24x20 Rotary Control Valves Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational

More information

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 ) I & M Mark 8 Series 30 Wasson Road Cincinnati, OH 4509 USA Phone 53-533-5600 Fax 53-8-005 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark 8 Control Valves (/ -

More information

GT-200 GATE VALVES PN16, Screwed end

GT-200 GATE VALVES PN16, Screwed end Document No. : MD-QO-04-281 Date : 2009/07 /17 Version : 1.0 GT-200 GATE VALVES PN16, Screwed end USER MANUAL Modentic Industrial Corporation 14F-1,No.57Taya Rd.,Taichung,Taiwan,R.O.C. Email:modentic@ms9.hinet.net

More information

Model DF269 Control Valve

Model DF269 Control Valve Figure 1 DF269 Control Valve TABLE OF CONTENTS Introduction 2 Fail Open Actuator Disassembly 6 General 2 Body and Packing Reassembly 7 Scope 2 Fail Closed Actuator Resassembly 8 Specifications 3 Fail Open

More information

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03 Double check valves for medium hazard rated applications Flanged and roll grooved end connections FEATURES GENERAL APPLICATION The DC0 provides protection from both backsiphonage and backpressure of the

More information

NEOTECHA NEOSEAL BUTTERFLY VALVE INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NEOSEAL BUTTERFLY VALVE INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

Baumann Little Scotty Bronze Control Valve

Baumann Little Scotty Bronze Control Valve Instruction Manual 24000 Valve Baumann 24000 Little Scotty Bronze Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Installation... 3 Air Piping...

More information

Yarway Que - Temp Desuperheater Standard-/heavy Duty Installation and maintenance Instructions

Yarway Que - Temp Desuperheater Standard-/heavy Duty Installation and maintenance Instructions Before installation these instructions must be fully read and understood Model 33 / 43 Installation of the Que - Temp Desuperheater Model 13 / 23 Before installation, check the Que - Temp Desuperheater

More information

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL FRP BALL VALVES TABLE OF CONTENTS MAINTENANCE AND INSTALLATION INSTRUCTIONS 1. 2. 2.1 2.2 2.3 2.4 GENERAL...Page 1 HANDLING...1 Receiving and Storing...1

More information

740G Double Disc Check. Valve. Operation / Maintenance Manual. General Information 2. Installation/Operation 3

740G Double Disc Check. Valve. Operation / Maintenance Manual. General Information 2. Installation/Operation 3 Operation / Maintenance Manual 740G Double Disc Check table of contents PAGE General Information 2 Installation/Operation 3 Troubleshooting & Disassembly/Reassembly 4 Parts Information 5 Valve! WARNING:

More information

Instructions for installation, operation and maintenance of: GATE VALVE

Instructions for installation, operation and maintenance of: GATE VALVE Instructions for installation, operation and maintenance of: GATE VALVE GEN GAC GAF/GENF TERMOVENT SC Temerin Republic of Serbia Instruction for installation, operation and maintenance: Table of Contents

More information

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting Before installation these instructions must be fully read and understood 4. Confirm that the materials of construction listed on the valve nameplate are appropriate for the service intended and are as

More information

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting Before installation these instructions must be fully read and understood 4. Confirm that the materials of construction listed on the valve nameplate are appropriate for the service intended and are as

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Wafer Style, Dual Plate Check Valves. To ensure efficient and safe operation

More information

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM INSTRUCTION MANUAL Anchor Darling 1878 Swing Check Valves Sizes 1/2 through 2 Installation Operation Maintenance FCD ADENIM0006-00 Table of Contents 1.0 Physical Description and Operation of Equipment

More information

Fisher V250 Ball Valve

Fisher V250 Ball Valve Instruction Manual Fisher V250 Ball Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Installation... 3 Maintenance... 6 Replacing the Follower Shaft Seal... 6 Replacing the Drive

More information

Model DF233 Control Valve

Model DF233 Control Valve Figure 1 DF233 Control Valve TABLE OF CONTENTS Introduction 2 Body and Packing Reassembly 7 Specifications 3 Fail Closed Actuator Reassembly 8 Valve Sizes 3 Fail Open Actuator Reassembly 9 Unpacking 4

More information

Newco / OIC / Cooper Forged Valves. Operation & Maintenance. Manual

Newco / OIC / Cooper Forged Valves. Operation & Maintenance. Manual NEWCO / OIC / COOPER VALVES Newmans Inc., Newmans Valve Ltd. Operation & Maintenance Manual Revision 2, 9 May 2007 1. Introduction and Safety Information... 1 1.1. Introduction... 1 1.2. Safety Information...

More information

Fisher CAV4 Control Valve

Fisher CAV4 Control Valve Product Bulletin D10197X012 Fisher CAV Control Valve CAV Valve The Fisher CAV control valve (figure 1) with Cavitrol IV trim is designed specifically for liquid applications, such as boiler feedwater recirculation,

More information

Fisher 9500 Butterfly Control Valve

Fisher 9500 Butterfly Control Valve 9500 Product Bulletin Fisher 9500 Butterfly Control The Fisher 9500 butterfly valve is a fully lined valve for use with corrosive fluids and where tight shutoff is required. The nitrile or PTFE liner totally

More information

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL

VSI, LLC SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL VSI SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES VSI, LLC. 2-0 SERIES 2100 RESILIENT SEATED BUTTERFLY VALVES INSTALLATION, OPERATION AND MAINTENANCE MANUAL Publication: V2100- August 2016 TABLE OF CONTENTS

More information

Fisher 1B and 1BR Constant Pressure Pump Governor Actuators

Fisher 1B and 1BR Constant Pressure Pump Governor Actuators Instruction Manual 1B Actuator Fisher 1B and 1BR Constant Pressure Pump Governor Actuators Figure 1. Fisher 1B Actuator on Direct Acting easy e Valve W2232 1 Introduction Scope of Manual This instruction

More information

Baumann Sanitary Control Valve

Baumann Sanitary Control Valve Instruction Manual 89000 Valve Baumann 89000 Sanitary Control Valve Contents Introduction... 2 Scope of Manual... 2 Educational Services... 2 Safety Precautions... 3 Maintenance... 4 Installation... 4

More information

Keystone K-LOK Series 36 and 37 High Performance Butterfly Valve Installation and Operation Manual

Keystone K-LOK Series 36 and 37 High Performance Butterfly Valve Installation and Operation Manual Before installation these instructions must be fully read and understood General Suggested installation orientation is with valve shaft horizontal or inclined from vertical. Unless otherwise recommended

More information

ENGINEERING STANDARD

ENGINEERING STANDARD PAGE: 1 OF 31 SUBMITTED BY: J. JOSEPH APPROVED BY: ED PEARSON Overview Vendor: Cameron Valves and Measurement 3250 Briarpark Drive Houston, Texas 77041 U.S.A. Telephone: 281-499-8511 Fax: (281) 261-3635

More information

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features Double check valves for medium hazard rated applications BSP screwed connections Features General application The DC03 provides protection from both backsiphonage and backpressure of the potable water

More information

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...

More information

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves Installation, Operation, Maintenance Instructions Standard Valves Series 035 000 Globe Valves Series 031 000 Angle Valves Series 033 000 3-Way-Valves 1 GENERAL INFORMATION These instructions are designed

More information

Fisher Vee-Ball V150 and V300 NPS 14 through 20 Rotary Control Valves

Fisher Vee-Ball V150 and V300 NPS 14 through 20 Rotary Control Valves Instruction Manual V150 and V300 Valves Fisher Vee-Ball V150 and V300 through 20 Rotary Control Valves Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Installation...

More information

Model DF2000 Control Valve

Model DF2000 Control Valve Figure 1 DF2000 Control Valve & DFC Actuator TABLE OF CONTENTS Introduction 2 Jam Style Packing - Figure 2 9 General 2 Body Reassembly 7 Scope 2 Seat Ring Installation 7 Specifications 3 Packing Box 7

More information

METERING VALVE 2" STEM GUIDED

METERING VALVE 2 STEM GUIDED 2" STEM GUIDED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed

More information

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been

More information

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting I & M 8000 Series 3170 Wasson Road Cincinnati, OH 45209 USA Phone 513-533-5600 Fax 513-871-0105 lowflow@richardsind.com www.lowflowvalve.com Installation & Maintenance Instructions for 8000 Series Low

More information

IOM Manual. IOM Manual. Series 76/77.

IOM Manual. IOM Manual. Series 76/77. IOM Manual IOM Manual Series 76/77 www.flowlinevalves.com Flow Line Valve and Controls, L.L.C. 110 Main Project Road Schriever, LA 70395 P.O. Box 677 Schriever, LA 70395 Phone 985-414-6004 * Toll Free

More information

HIGH PRESSURE CONTROL VALVE R2L ACTUATOR

HIGH PRESSURE CONTROL VALVE R2L ACTUATOR R2L ACTUATOR All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual API 6D Piston Check Valve - IOM: Installation, Operation and Maintenance Manual 1/16 Table of Contents 1 INTRODUCTION... 3 1.1 SCOPE... 3 1.2 DISCLAIMER...

More information

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3 - 12 AMERICAN AVK COMPANY AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12" TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION

More information

Fisher ENVIRO SEAL Packing System for Rotary Valves

Fisher ENVIRO SEAL Packing System for Rotary Valves D0X0 July 07 Fisher ENVIRO SEAL Packing System for Rotary Valves Contents Introduction... Scope of Manual... Valve/Actuator Shaft Coupler... Description... Installation... Removing the Actuator... Installing

More information

Fisher 657NS Diaphragm Actuators Size 40, 45, 70, and 80

Fisher 657NS Diaphragm Actuators Size 40, 45, 70, and 80 Instruction Manual 657NS Actuator Fisher 657NS Diaphragm Actuators Size 40, 45, 70, and 80 Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 3 Educational Services... 3

More information

Yarway 7100 Series ARC Valve non-filtered design Installation and maintenance instructions

Yarway 7100 Series ARC Valve non-filtered design Installation and maintenance instructions Before installation these instructions must be fully read and understood either: 1. Keep the main body of valve below 300 F during preheat, welding and post weld heat treatment. OR 2. Disassemble the valve

More information

PRESSURE/TEMPERATURE RATINGS ASME B16.34 VALVES

PRESSURE/TEMPERATURE RATINGS ASME B16.34 VALVES Emerson valve materials that conform to ASME 16.34 standard class pressure/erature ratings. IMPORTANT INFORMATION FOR TABLES 1. Emerson valves conforming to ASME B16.34 standard have specific pressure/erature

More information

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life! Instructions and operation manual for butterfly valves This manual is intended to support the users of Herberholz butterfly valves type HRD/HRA, RD/RA, LDKE/LDKF for installation, operation and maintenance

More information

Installation, Operation, and Maintenance Manual Full Port Y-Pattern, Bolted Bonnet, Globe and Check Valves

Installation, Operation, and Maintenance Manual Full Port Y-Pattern, Bolted Bonnet, Globe and Check Valves SMITH VALVES Installation, Operation, and Maintenance Manual Full Port Y-Pattern, Bolted Bonnet, Globe and Check Valves Globe Valve Series: YG80/YG15 Welded Bonnet Globe Valve Series: YG87/YG17 Piston

More information

Fisher Z500 Severe Service Ball Valves

Fisher Z500 Severe Service Ball Valves Z500 Ball Valves D099X0 Product Bulletin 5.:Z500 April 06 Fisher Z500 Severe Service Ball Valves This bulletin covers Fisher NPS / 6 Z500 Severe Service Ball Valves. The Z500 severe service ball valve

More information

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822 Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822 Statements: NIBCO High Performance Butterfly Valves, Series 6822 and 7822, have been designed

More information

YARWAY NARVIK VEN-TEMP DESUPERHEATER MODEL 25

YARWAY NARVIK VEN-TEMP DESUPERHEATER MODEL 25 Yarway covers requirements for Desuperheaters, pneumatic actuators, strainers with a wide range of models, sizes and materials to satisfy all the specifications of the power, pulp and paper industry and

More information

740G Double Disc Check Valve

740G Double Disc Check Valve OPERATION/MAINTENANCE MANUAL 740G Double Disc Check Valve TABLE OF CONTENTS PAGE General Information 2 Installation / Operation 3 Troubleshooting / Assembly 4 Parts Information 5 WARNING: 1. Read all applicable

More information

KTM V-PORT CONTROL BALL VALVE FULL BORE AND REDUCED BORE

KTM V-PORT CONTROL BALL VALVE FULL BORE AND REDUCED BORE A rugged, long-life V-port control ball valve with excellent flow characteristics for various fluids including slurries and fibers FEATURES GENERAL APPLICATION Steam, liquids, gas or critical services

More information

Type 1089 Valve Valve

Type 1089 Valve Valve Instruction Manual 1089 Valve Type 1089 Valve Contents Introduction............................... 1 Scope of manual......................... 1 Description.............................. 2 Specifications............................

More information

Serie 2003/2013. Three-way Control Valve, mixing/diverting. Wörth am Main. Service. Control Valve Division

Serie 2003/2013. Three-way Control Valve, mixing/diverting. Wörth am Main. Service. Control Valve Division Serie 2003/2013 Three-way Control Valve, mixing/diverting Service Preventive maintenance Preventive maintenance primarily consists of making a regular visual inspection of the valve assembly. This can

More information

Series Single seated top guided control valve. Preventive maintenance. Overhauling procedure. Wörth am Main SERVICE NOTE. Control Valve Division

Series Single seated top guided control valve. Preventive maintenance. Overhauling procedure. Wörth am Main SERVICE NOTE. Control Valve Division Series 2000 Single seated top guided control valve Subject to change without notice Fig. 1: Series 2000 valve assembly Preventive maintenance Preventive maintenance consists of making a periodic visual

More information

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE Page 1 of 13 1.1 General CHAPTER 1 - GENERAL INFORMATION This manual contains maintenance instructions with pertinent

More information