Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5
|
|
- Elisabeth Bradford
- 5 years ago
- Views:
Transcription
1 2.19 AZM 19 range ,3 3 1 Features Voltage variants Approvals Thermoplastic enclosure Manual / Emergency release Long life Actuation on de-energisation or energisation Slim design, particularly suitable for fitting on hinged doors, aluminium profiles and fencing Actuating head can be turned in 4 steps of 9 Sealing mechanism to prevent the ingress of dirt 2 cable entries Wiring compartment Holding force 1, N 24 VDC 24 VAC 48 VAC 11 VAC 23 VAC Always state required supply voltage when ordering H D 11 4, 72 M , 22, 17, 23, Manual release Emergency release For manual release using triangular key For maintenance, setting-up, etc. In case of danger Fitting only within the protected area 8 Schmersal
2 2.19 AZM 19 range Actuation on de-energisation 11 E1 E NC 2 NC Contacts/ Switch travel 1, 2,3 3, , ,3 3, With manual release With emergency release AZM 19-11/1rk AZM 19-11/1rkn AZM 19-2/1rk AZM 19-2/1rkn AZM 19-11/1rk AZM 19-11/1rkn Actuation on energisation 11 E1 E NC 2 NC Contacts/ Switch travel With manual release 1, 2,3 3, AZM 19-11/1rka 11-2,3 2 3 AZM 19-2/1rka ,3 3, 3 AZM 19-11/1rka Notes Info Circuit diagrams show de-energised condition with actuator inserted ( in switch travel diagram). Actuators must be ordered separately. A selection of suitable actuators can be found in 2.2. Interlocks with actuation on energisation may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. LED version on enquiry Schmersal 9
3 2.2 Actuators Straight actuator AZM 19-B1 Particularly suitable for sliding doors Compensation for tolerances by means of rubber buffers Play of key in interlocked condition approx. mm at 9 to the plane of the actuator 17 mm, minimum actuating radius in line with the plane of the actuator mm The axis of the hinge should be 7. mm above the top Actuator with front fixing AZM 19-B Particularly suitable for front mounting e.g. on hinged guards Play of key in interlocked condition approx. mm at 9 to the plane of the actuator 2 mm, minimum actuating radius in line with the plane of the actuator mm The axis of the hinge should be 1. mm above the top Adjustable actuator AZM 19-B3/2x1 For very small actuating radii at 9 to or in line with the plane of the actuator Play of key in interlocked condition approx. mm at 9 to the plane of the actuator 27 mm, minimum actuating radius in line with the plane of the actuator 3 mm The axis of the hinge should be 2 mm above the top 13 Schmersal
4 2.2 Actuators Adjustable actuator AZM 19-B3/1 With actuator preset at 1 for small actuating radii Play of key in interlocked condition approx. mm at 9 to the plane of the actuator 1 mm The axis of the hinge should be 2 mm above the top Adjustable actuator AZM 19-B3/7. With actuator preset at 7. Play of key in interlocked condition approx. mm at 9 to the plane of the actuator 17 mm The axis of the hinge should be 2 mm above the top Schmersal 131
5 2.21 Accessories Mounting plate MP 19 For simple mounting of an AZM 19 on profile systems M , , Additional entry ZPG 19 Cover with Pg cable entry, Triangular key M3 For manual release Part number: Straight: Triangular key M3 (included in delivery) With lever: Triangular key M3-a 132 Schmersal
6 2.27 Technical data AZM 17-F AZM 17-Z AZM 19 AZM 17i-F AZM 17i-Z Standards: IEC/EN /DIN VDE-2; EN 188; BG-GS-ET-19 Enclosure material: Glass-fibre reinforced thermoplastic, self-extinguishing Glass-fibre reinforced thermoplastic Actuator and latching bolt: Stainless steel Zinc-plated metal / aluminium Protection class: IP IP 7 to IEC/EN 29/DIN VDE 47-1 Contact material: Silver Contact type: Changeover with double break Zb, Changeover with with galvanically separated contact bridges double break Zb with galvanically isolated moving contacts Switching system: A IEC ; B BG-GS-ET-19; slow action, NC contacts with positive break Termination: Removable terminal block with cage clamps Screw terminals for max. 2. mm 2 max. 1. mm 2 cables (including conductor ferrules) Rated impulse withstand voltage U imp : 4 kv 2. kv Rated insulation voltage U i : 2 V 4 V Thermal test current I th : 1 A Utilisation category: AC-1 AC-1; DC-13 Rated operating current/voltage I e /U e : 4 A/23 V 8 A/23 V, A/24 VDC Max. fuse rating: A gl/gg D-fuse 1 A gl/gg D-fuse Positive break travel: 11 mm 2 x 3. mm Positive break force: N for each NC 2 N contact fitted Solenoid duty rating: Continuous operation Rated control voltage U S : 24 VAC/DC 24 VDC; 48 VAC; or 11 VAC/DC, / Hz 11 VAC; 23 VAC or 23 VAC/DC, / Hz Consumption: Max. 1 W Max. 8. W Ambient temperature: C + C C + C Mechanical life: > 1 million operations 2 million operations Holding force F max. : 1, N 1, N Holding force of integral ball latch: Latching force: 3 N Schmersal 13
Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5
.1 AZM 11 range Features Thermoplastic enclosure Manual and emergency release Long life Double insulated X High holding force, N N latching force Wiring compartment Actuation on de-energisation or energisation
More informationSolenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11
2.4 AZM 170 range Features Thermoplastic enclosure Compact design Manual release Long life Double insulated X High holding force 1,000 N N latching force Cut clamp termination Actuation on de-energisation
More informationSolenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5
2.22 415 range Features Metal enclosure Two switches in one enclosure Problem-free opening of stressed doors by means of bell-crank system Robust design Long life High holding force 3,500 N Adjustable
More informationAZM 161SK 12/12RKED/TU 024
10.06.2016 10:17:13h Datasheet AZM 161SK 12/12RKED/TU 024 Solenoid interlock / AZM 161 Thermoplastic enclosure Double insulated Interlock with protection against incorrect locking. 130 mm x 90 mm x 30
More informationTechnical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19
1 echnical data echnical data, 1 0 3 1 104 7 90 Interlock with protection against incorrect locking hermoplastic enclosure contacts Manual release, emergency exit or emergency release Long life Double
More informationOrdering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161
10.06.2016 10:18:33h Datasheet AZM 161SK 12/12RKED/TU 110/230 Solenoid interlock / AZM 161 Thermoplastic enclosure Double insulated Interlock with protection against incorrect locking. 130 mm x 90 mm x
More informationSafety door-handle system STS
Safety door-handle system STS Full body access ha Safety door-handle system STS EN 1037 Features The safety door-handle system is suitable for all types of safety guards. Safety switches and solenoid interlocks
More informationOperating instructions Solenoid interlock EX-AZM About this document. Content
EX-AZM 161 1. About this document Operating instructions.............pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information
More informationOperating instructions Solenoid interlock AZM 161../.. 1. About this document. Content
Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides
More informationTechnical data. Standards: IEC/EN BG-GS-ET-15
1 Technical data Contact variants 7 30 2 2 Long life Multiple coding Thermoplastic enclosure Double insulated X 3 cable entries M20 Large wiring compartment High level of contact reliability with low voltages
More informationOperating instructions Solenoid interlock AZM 161../.. 1. About this document. Content
Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides
More informationSafety Switches with Separate Actuator SKC
Safety Switches with Separate Actuator SKC In terms of lengths, the SKC safety position switch is the 15 mm shorter variant of the SK. This makes it the right choice for confined installation conditions.
More informationSolenoid interlock AZM 200 The non-contact interlock.
Solenoid interlock AZM 200 The non-contact interlock. Solenoid interlock AZM 200 The non-contact Solenoid interlocks demand accurate alignment of actuator and device. This requirement is met on new machinery.
More informationCommand devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.
.1.1.1 One-side operation ZS 71 range 40 30 ø10 10 22 6 8 53,5 18 24 105 33 56 Pg 13,5 52 17,5 42 15 Features To EN 418 Metal enclosure 2 contacts Small body 2 cable entries Various spring force variants
More informationRecommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.
Metal-Enclosed Limit Switches ENM2 Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications. Product advantages Standard switch
More informationSERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications
SERIES AZM170 Description The AZM170 Series is designed for machines/work cells where access to a hazardous work area must be controlled until safe conditions exist. Their solenoid-latching feature permits
More informationInstallation and Operating Instructions
Plastic encased safety interlocking switch Type PSEN me4 Intended use The plastic encased safety switches PSEN me4 with separate actuator are suitable for the mounting on safety guards. They are designated
More informationOperating instructions Solenoid interlock TKM/TKF. 1. About this document. Content
1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning
More informationTechnical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :
55 Two-hand control panels SEP System components 460 240 190 30 Standards: IEC/EN 60947-5-5 EN 574 EN 418 cast aluminium, powder-coated Protection class: IP 65 Cable section: max. 1.5 mm 2 U i : 440 V
More informationDatasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350
Datasheet - AZ 3350-12ZUEK Safety switch with separate actuator / AZ 3350 Metal enclosure Latching handle Long life 40,5 mm x 114 mm x 38 mm High level of contact reliability with low voltages and currents
More informationInstallation and Operating Instructions
Plastic encased safety interlocking switch Type PSEN me2/psen me3 Intended use The plastic encased safety switches PSEN me2 and PSEN me3 with separate actuator are suitable for the mounting on safety guards.
More informationSafety switches / Position switches / Command devices
Safety switches / Position switches / Command devices SAFE SWITCHGEAR FOR DEMANDING AND CRITICAL APPLICATIONS // Control technology / Catalogue 4 The Company PRODUCTS 8 Safety switches with separate actuator
More informationDatasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521
Datasheet - TV8S 521-02/20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521 Metal enclosure Good resistance to oil and petroleum spirit Mounting independent of hinge 92 mm x 81,5 mm x
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS CONTACT BLOCKS FR FX FK FW 5 6 7 11 1 14 NC NC
More informationFloor and fine adjustment switches
Floor and fine adjustment switches 6 Introduction 6-2 AS 1 6-3 ASH 2 6-4 AFH 2 6-5 Reference table technical data 6-6 Universal switches 6-7 Floor and fine adjustment switches / Introduction ➀ ➁ ➂ Floor
More informationOperating instructions Solenoid interlock AZM /.. 1. About this document. Content
Solenoid interlock AZM 415-../.. 7 Appendix 7.1 Comparison of the old and new contact configurations...6 8 EU Declaration of conformity Operating instructions.............pages 1 to 8 Original 1. About
More informationDoor locking devices. 4 Schmersal Industrial Switchgear
with and without a checking device The door locking devices from the AV series serve the purpose of monitoring and interlocking of 1- and 2-leaf lift landing doors. The safety locking devices fulfil the
More informationSafety switches for hinged doors
4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland
More informationGuard locking systems for the protection of man and machine
Guard locking systems for the protection of man and machine K. A. Schmersal GmbH Safety Control Systems Möddinghofe 30 D - 42279 Wuppertal P.O. Box 24 02 63 D - 42232 Wuppertal Germany Phone +49 - (0)2
More informationControl Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België
Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part
More informationOperating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content
. bout this document Operating instructions.............pages to 8 Original. Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning
More informationSERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE
SERIES Z/T23 Safety-Rated, Positive-Break Miniature DIN Limit Switches Features & Benefits Positive-Break NC contacts won t stick or weld shut. Watertight design meets IP washdown requirements. Rugged,
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow
More informationSafety switches for hinges
Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded
More informationTechnical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC
AZM 00,,,,, M0x1, 0 1, AZM 00➀-T-➁➂ 0 1 Solenoid interlock (Solenoid interlock monitoring) Thermoplastic enclosure Sensor technology permits an offset of ± mm between actuator and interlock Intelligent
More informationSafety switches with solenoid and separate actuator
Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because
More informationSwitches with manual reset
Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever
More informationPosition switches FR series
Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33
More informationSingle foot switches PX and PA series
A Single foot switches PX and PA series Selection diagram CARRYING ROD See page /10 ADDITIONAL METAL PROTECTION OPEN PROTECTIONS CLOSED PROTECTIONS PA PA 2 CONTACT BLOCKS COMBINATIONS 01 02 1NO+1NC snap
More informationSafety switches with solenoid and separate actuator
Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because
More informationFL series position switches
FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable
More informationNHP SAFETY REFERENCE GUIDE
NHP SAFETY REFERENCE GUIDE 3. PRODUCTS Safety Switches Safety Interlock Switches ST14 Series Light duty safety interlock switch, ideal for guard door monitoring applications. Thermoplastic enclosure Double
More informationSFS-UFS Single Foot Switches
SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes
More informationLR-LX-LK-LW Safety Switches with separate actuator
LR-LX-LK-LW Safety Switches with separate actuator Technopolymer housing, from one to three conduit entries Protection degree IP67 15 contact blocks available 8 stainless steel actuators available Versions
More informationLimit Switches - Safety Type Plastic Body IP65 and Metal Body IP66
Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66 Product Description They are developed in order to be used for following operations: For monitoring and protection of industrial machines,
More informationPosition switches FD series
Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever
More informationStandard Rope Pull Switches. With and Without Latching Function SIEM2 SID SIN SGC SI88. The field of application for these rope pull switches includes
Standard Rope Pull Switches With and Without ing Function SEK SEM2 SIEM2 SD SID SID SIN SGC SI88 Because of their specifications governed by corresponding standards (see Cable Safety Pull Switches SRM/SR),
More informationAutomation // SYSTEMATIC CONTROL SWITCHGEAR. Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches
Automation // SYSTEMATIC CONTROL SWITCHGEAR Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches 6 Emergency pull-wire switches // Selection table Emergency pull-wire switches from page
More informationOperating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content
1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning
More informationLimit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66
Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66 Double Insulation (for thermoplastic type) High mechanical resistant Degree of protection IP65 (thermoplastic) IP66
More information1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches
. Product Description Eaton s LS-Titan safety interlock switches have been specifically designed for monitoring the position of protective guards, such as doors, flaps, hoods and grilles. All switches
More informationTechnical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.
8 Innovations 2/2 - Control panel BDF 2 BDF 2 5.5 22 29 39 3 4 6- Slim, shock-resistant plastic enclosure Can be fitted onto customary aluminium profile systems Can be installed in the most favourable
More informationOperating instructions Solenoid interlock AZM 170
Solenoid interlock AZM 170 1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions FR NL JP Vous trouverez la version actuelle du mode d emploi dans
More informationLK Position Switches TECHNICAL DATASHEET.
LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationPosition switches FR series
Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket
More informationUnder the aspect of simplified
Interlocking devices with and without guard locking This catalogue presents safety door interlocks and hinge monitoring switches. Models from the product range of many years standing continue to be available,
More informationSingle foot switches - PX and PA series
Single foot switches - PX and PA series Description The PX and PA foot switches are traditional products of Pizzato Elettrica that have recorded a continuous growth and success in the market. Modified
More informationSingle foot switches PX and PA series
Single foot switches PX and PA series Technical data Housing Made of polymer glass-reinforced shock-proof thermoplastic resin with double insulation Bedplate with non-skid rubber feet. Actuation force:
More informationSafety Sensor CSS 180 Product Information
Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 CSS180CSS 180 PDF-M / EN 60947-5-3 EN 954-1 Control Category 4 IEC 61508, suitable for use in SIL 3 applications BG Type-Certification in
More informationPrewired position switches FF series
2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable
More informationPosition Switches Series 8074/2
www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,
More informationApprobationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking
Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description
More informationHinged Safety Door Switch
Hinged Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. Two actuator types are available: Shaft Arm lever Arm lever type can be adjusted to allow a right (180 ),
More information3SE3 1 SIGUARD Position Switches
3SE3 SIGUARD Position Switches Metal-enclosed, with Moulded Cable Description Technical data Description In harsh industrial environments and in installations with limited space, the small 3SE3 6 and 3SE3
More informationS826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en
2 Snap-action switches S826, S26 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en 2 Snap-action switches S826 Series Dual changeover switches with positive
More informationDatasheet - MV8H Y
18.03.2014-17:45:05h Datasheet - MV8H 330-11Y Position switch / light Position switch / M 330 / M 330 Roller lever 8H Preferred typ Metal enclosure Long life 40 mm x 76 mm x 40 mm ( basic component) Suitable
More informationDATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.
DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN
More informationSafety Switches NP GP TP. More than safety.
Safety Switches NP GP TP More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
More informationGeneral_technical_data Series
Actuator with snap-action switching element Switching system Self-cleaning, double-break snap-action switching system with contact opening width 2 x 0.5 mm (switch with small contact opening width as per
More informationD4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -
Guard Lock Safety-door Switch Polymer housing, IP65, and slow-action contacts with positive opening. 2 versions Mechanical lock/solenoid release Solenoid lock/mechanical release Rotatable operating head
More informationSafety rope switch without reset for simple stop
afety rope switch without reset for simple stop election diagram FP 4-M2 FD 4-M2 FL 4-M2 FR 4-M2 FM 4-M2 FX 4-M2 FZ 4-M2 ACTUATOR 9 ACTUATOR 9 0 CONTACT BLOCK 1 9 21 1NO+ FP FD FL FC 33 34 CONDUIT ENTRIE
More informationPosition switches FC series
A Position switches FC series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere 6 adjustable lever safety adjustable lever
More information3SE3 2 SIGUARD Position Switches
3E3 2 IGUARD Position witches Description Application The function of position switches (limit switches) is to produce electrical signals corresponding to the positions by moving machinery. The units are
More informationPosition Switches Series 8060/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationAutomation // SYSTEMATIC CONTROL SWITCHGEAR. Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches
Automation // SYSTEMATIC CONTROL SWITCHGEAR Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches 4 The Company PRODUCTS 8 Emergency pull-wire switches 12 Selection table Emergency pull-wire
More informationSafety rope switches with reset for emergency stop
Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available
More informationOperating instructions Solenoid interlock AZM About this document. Content
Solenoid interlock AZM 200 7 Set-up and maintenance 7.1 Functional testing...7 7.2 Maintenance...7 Operating instructions............pages 1 to 10 Original 8 Disassembly and disposal 8.1 Disassembly...7
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Deliveryprogram Contactorrelay,2N/O+2N/C,DCcurrent Partno. DILER-22-G(220VDC) Articleno. 010091 CatalogNo. XTRM10A22BD Product range DILER Mini-contactors Application Contactor relays Description with
More informationFOOT SWITCHES
- 83 - FOOT SWITCHES PS... / PD... Foot Switches Double insulation - Plastic Casing IP65 Description Applications Foot switch operated machines such as: shearing machines, spinning machines, spinning lathers,
More informationSafety switches for hinged doors
4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationOperating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...
Safety sensor BNS Disassembly and disposal. Disassembly..... Disposal... EU Declaration of conformity Operating instructions.............pages to Original x.000 / 0.0 / v.a. - 09009- / J / 0-0-0 / AE-Nr.
More informationEmergency pull-wire, Belt-alignment, Slack-wire switches. Automation. Catalogue // SYSTEMATIC CONTROL SWITCHGEAR
Automation Emergency pull-wire, Belt-alignment, Slack-wire switches // SYSTEMATIC CONTROL SWITCHGEAR Catalogue 4 The Company PRODUCTS 6 Emergency pull-wire switches 12 Selection table Emergency pull-wire
More informationOnline data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES
Online data sheet i15-em03 Lock i15 Lock i15-em03 Lock i15 Lock A B C D E F actuator not supplied with delivery Ordering information Type Part no. i15-em03 Lock 6034028 The actuator has to be ordered separately.
More informationPosition Switches Series 8070/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationAn Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches
An Investment in Plant Floor Safety 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches Notes 2 802C Cable Pull Safety Switches Safety and Application Safety
More informationApplication Mini Contactors for Motors and Resistive Loads
Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads
More informationAZM300 More than just a solenoid interlock
AZM300 More than just a solenoid interlock AZM300 The one for all Symmetrical mounting for right- and left-hinged doors Only one version for hinged and sliding doors Compact design Can be used as end stop
More informationW Datasheet: DIN Rail Contactors, series AMPARO
W Datasheet: DIN Rail Contactors, series AMPARO W SCHRACK-INFO For suiting of fans, pumps, heating & lighting Noise reducing design Low vibration on DIN-rail 230V 50/60Hz oder 24V 50/60 Hz coil DIN-Rail
More informationSafety-door Switch. Ordering Information
Safety-door Switch Safety-door Switch s Special Operation Key Positively Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Special Operation Key prevents mis-operation.
More informationLimit Switch - Prewired Type Metal Body
Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationLimit Switches - Limit Type Plastic Body IP65
Limit Switches - Limit Type Plastic Body IP65 Double Insulation Degree of protection IP65 Reinforced UL-V thermoplastic fiber-glass body Positive Opening Operation Minimum Actuation Force/Torque Minimum
More informationSafety Limit Switches
Safety Limit Switches with separate actuator Z02: Snap action 2NC Y+Y 3 Bent key 4 Flat key 5 Bent key 6 Flat key 7 Shock absorbing bent key 8 Shock absorbing flat key 9 Adjustable joint key Z11: Snap
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationDouble insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators
Double insulated, types XCK-P and XCK-T Presentation XCK-P with 1 cable entry, conforming to CENELEC EN 57 With head for linear movement (plunger) operators Page 18 With head for rotary movement (lever)
More informationGKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch
Series Dual Entry Solenoid Key Operated Safety Interlock Switch FEATURES Solenoid power to lock or power to unlock Side or top key entry Separate switches for key position and solenoid status Available
More information0190 / Tolerance in psi (bar) at room temperature. Adjustment range in psi (bar) psi. ± 2.90 psi. (± 0.2 bar) (0.3-1.
0190 / 0191 Diaphragm / piston pressure switches up to 24 V with gold contacts Zinc-plated steel (CrVI-free), with spade terminal Snap action with gold contacts Overpressure safety up to 1,450 / 4,350
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Deliveryprogramme Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILER-31-G-C(110VDC) Articleno. 231831 CatalogNo. XTRMC10A31E0 Product range DILER Mini-contactors Application Contactor relays Description
More informationSafety rope switch with reset for emergency stop
Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With
More information