INSTRUCTION MANUAL FOR JB SERIES THYRISTOR REGULATOR

Size: px
Start display at page:

Download "INSTRUCTION MANUAL FOR JB SERIES THYRISTOR REGULATOR"

Transcription

1 INST.No. INE9A INSTRUCTION MANUAL FOR SERIES THYRISTOR REGULATOR (Phaseangle firing system/ zerocross firing system) Thank you for your purchase of thyristor regulator series. Please read this instruction manual carefully to use this unit correctly and safely and also prevent a trouble in advance. Check your model. Check your model and its specifications. To our sales agent and instrumentation contractor Deliver this instruction manual to your final user. To user Keep this instruction manual until you throw into the discard. Contents Cautions on safety. Names of component parts. Installation. External dimensions. Settings 8. Connections 9. Operation. Maintenance 8. Accessories 9. Troubleshooting. General specifications Model Code A label showing the model code is pasted to the upper part of your unit. Label MODEL No.A Model code Serial No. Rated current : A : A : A : A : A : A Attachment Name Remarks Quantity Instruction manual This manual copy Accessories (Separate purchase is required.) For details, refer to Para. 8 (Page ). Setters Fuse units Rapid fuses VLJAL FUJ PFFU VLJMH FUJA URIC VLJHL FUJA URIC VLJAM FUJA URIC FUJA URIC FUJA CRLSG

2 8 KUMANOCHO,ITABASHIKU,TOKYO,8 Telephone: 89 Facsimile: 899 January, nd edition

3 CAUTIONS ON SAFETY. Preconditions for Use This unit is to be mounted inside an indoor instrumentation panel.. Symbol Marks Employed in This Unit Use in this unit. Labels Alert symbol mark Caution on high temperature Grounding terminal RATING A Rated current Meanings Caution on handling for prevention of an electric shock, injuries, or other accidents. Caution on a hot point (radiation fin) for prevention of burn. Connect a grounding part (mounting hole) to the protective conductor terminal of the power supply equipment. Make sure that the maximum load current is lower than the rated current. Use in this manual. Labels War ning Caution Reference Meanings The nonobservance of information under this symbol may result in hazardous, critical or serious injury to the user. The nonobservance of information under this symbol may result in a hazardous situation or a light injury to the user or in physical damage to the property. Information that you can use as a reference.. Summary This compact and lightweight singlephase thyristor regulator is designed for high density panel installation, and is applied to wide heating control applications with its various functions including phaseangle firing system/zerocross firing system selection, soft start time setting, and lowerlimit setting. Warnings/Cautions. Mounting direction Mount your unit vertically with its main circuit terminals (U, U) placed downward to ensure aircooling effect ventilated through its air duct structure.. Don t use your unit on any desk. Make sure to mount your unit on a panel to prevent its trouble or an injury to you by its falling down.. Mounting environment Don t operate your unit at a place where an explosive gas, an inflammable gas, or vapor exists.. Don t repair or modify your unit. To prevent an electric shock accident, a fire, or its trouble, don t repair, modify, or disassemble your unit by any person other than our qualified serviceman.. Turn the power supply off for an abnormal symptom. If you have abnormal odor, abnormal heating, or other abnormal symptoms, turn the power supply off, and inform of it to your nearest agent of CHINO Corporation. Request for securing the safety. Use your unit at lower than the rated current. Confirm the rated current on the label pasted on the upper part of your unit.. Connect a load before turning the power supply on. Never turn the power supply on without connecting a load in advance to prevent its trouble.. Applicable load A resistive load is applicable. An inductive load (transformer primary control, maximum magnetic flux density.t) is applicable only when the phaseangle firing system is selected.. Mounting of a rapid fuse Mount a rapid fuse (Separate purchase is required.) for protecting thyristor elements.. Countermeasure against digital units Higher harmonic noises are generated when your unit is used with the phaseangle firing system. Use an insulation transformer, separate your unit from a drive power line, or take other countermeasures.. Don t use any unused terminals. Don t connect any signal to any unused terminals to prevent a trouble.

4 . NAMES OF COMPONENT PARTS The appearance is sorted into kinds according to the rated current. The following appearance is A type. The appearance in other types is almost same as this A type. UP mark 8 Control input terminals to V DC:Short terminals and to ma DC:Short terminals and UP INPUT ma V INPUT POWER GAIN LOW Mounting hole (M) Power lamp Internal gradient setting Internal lowerlimit setting Soft start time setting 9 Setter connection terminals Manual (M) M M SOFT SW ON SW SW/control selector switch ON : Zerocross firing system OFF : Phaseangle firing system SW/unused (Fixed to OFF) Power terminals V to V AC V to V AC V U AC V 8 9 SERIES THYRISTOR REGULATOR U U Main circuit terminals Names Functions Power lamp Internal gradient setting Internal lowerlimit setting Soft start time setting SW/control selector switch SW/unused (Fixed to OFF) Main circuit terminals 8 Control input terminals 9 Setter connection terminals Power terminals Lights (green) when power is applied to power terminals 8, 9, and. Flickers in the determining period of power frequency when the power supply is applied. Is used to set gradient. The gradient becomes % when you turn this trimmer clockwise fully. Set this trimmer to % usually. An external gradient can be also connected for current/voltage input. Is used to set the output value when the control input is % (or ON between H and C terminals). The output value becomes % when you turn this trimmer counterclockwise fully. Set this trimmer to % usually. An external lowerlimit can be also connected for contact input. Is used to set the soft start time. The soft start time becomes about. second when you turn this trimmer counterclockwise fully or it becomes about seconds when you turn this trimmer clockwise fully. Selects either zerocross firing system (ON) or phaseangle firing system (OFF). Not used. Make sure to keep it turned off. Main circuit terminals (U, U) to thyristor elements These input terminals are for a current ( to madc) signal or a voltage ( to VDC) signal to control output. For current/voltage input For the connection to a gradient or a manual placed externally. For contact input For the connection to output terminals ( H C L ) of a controller, a higherlimit or a lowerlimit. These terminals are for the power supply to this unit.. For the power supply of to VAC, connect to the terminals 8 and 9. For the power supply of to VAC, connect to the terminals 8 and.

5 . INSTALLATION Warning Make sure to turn the power source off before installation to prevent an electric shock accident. This unit is designed as a backofpanel type to be mounted inside a panel, except for accessories (s, etc.).. Mounting Dimensions For A and A For A and A. Cautions on Installation M (mm screw hole x ) M (mm crew hole x ) Mount this unit with the UP mark( )facing upward. Ambient temperature and allowable current Mount this unit at a clean and wellventilated place free of dust particles. Separate this unit from a high temperature generating unit or similar unit. Keep a radiation space (more than mm) above and below this unit. Don t mount this unit at a place subjected to vibrations and shocks. Don t mount this unit in corrosive gas atmosphere. Rated current (%) 8 Ambient temperature ( ) Unit: mm Unit: mm The rated current is specified at an ambient temperature of o C as a reference. If the ambient temperature exceeds o C, reduce the load current, referring to the right figure. (The maximum operating temperature is o C. Use this unit at a current lower than 8% of the rated current in this case.) 8 Secure sufficient strength of the mounting plate (panel). (More than mm thickness is required for an iron plate.) Rated current and weight Rating current Weight Minimum space when units are mounted horizontally. Minimum space when units are mounted horizontally. For A and A M (mm screw hole x ) A About.kg Reference Mounting of accessories A About.kg Refer to the external views and mounting diagrams in [8. Accessories] A A A About.kg About. kg About.9kg 88 A About.9kg.. Unit: mm Minimum space when units are mounted horizontally. (Caution) Keep a radiation space of more than mm above and below this unit.

6 . EXTERNAL DIMENSIONS For A and A For A and A.. M mounting hole.. M mounting hole UP INPUT ma POWER GAIN INPUT ma V UP POWER GAIN V INPUT LOW INPUT LOW SOFT SOFT SW ON SW ON (M).. (M) SW M M V U 8 AC 9 V SERIES U U M M V U 8 AC 9 V U SW U Unit : mm Unit : mm For A and A. φ. M mounting hole UP INPUT ma V INPUT POWER GAIN LOW (M) M SOFT SW ON SW 88. M V U AC 8 9 V. SERIE U U Unit : mm

7 . SETTINGS Caution When you change the control system, we recommend to turn the power source off. For the gradient setting and the lowerlimit setting, change the settings gradually to avoid affection to a lord or peripheral units by an abrupt change of output.. Control System Selection (SW) OFF SW OFF: Phaseangle firing SW system(default) ON: SW: Not used (Fixed to OFF) Zerocross firing system. Setting (GAIN) External gradient Not connected Connected Set the gradient by this trimmer Output (%) Set this trimmer to % and set the gradient by an external gradient.. Lowerlimit Setting (LOW) This trimmer is used to set the output value when the control input is %. Set this trimmer to % by turning it fully counterclockwise usually. Output (%) % % Control input (%) % % Control input (%) The above figure shows the lowerlimit setting when the gradient is set to %.. Soft Start Time Setting (SOFT) The soft start time becomes approx. seconds when turning this trimmer fully counterclockwise, and becomes approx. seconds when turning this trimmer fully clockwise POWER % % GAIN % % LOW sec sec SOFT Reference Power lamp (Lights green when power is supplied) setting trimmer Lowerlimit setting trimmer Soft start time setting trimmer Control system selector switch (SW) Phaseangle firing system..the system for controlling the output by changing the conductive angle θ (ON timing) in the half cycle (8 o ) of the power supply. The control becomes continuous as compared with the zerocross firing system. This control system is also used for transformer primary control. However, since the output contains higher harmonics, it may cause external noises. Zerocross firing system..the systems for controlling the output by deciding ON/OFF in every cycle of the power supply. Since the power supply is turned on from V (zero cross point) voltage, noises are reduced as compared with the phaseangle firing system. However, since the maximum current flows during each ON cycle it may cause flickering. Reference Control system Soft start This function is provided to increase the output gradually up to the specified output when the power supply is turned on or when the control input value changes abruptly. This function can prevent a surge current from being generated due to an abrupt change of the primary control output of transformer. You can set the time (from % to % output) from about second to seconds. 8

8 . CONNECTIONS Warning Turn the power source off before connections to prevent an electric shock accident. Perform connections by experienced persons having the basic knowledge of wiring.. Cautions on Connections For the connections to the main circuit, use a cable having a sufficient allowance to a load current. For the connections to other terminals, twist. ~.mm cables.. Main Circuit Terminals/Power Terminals (U, U / 8 9 ) Make sure that the phase of the main circuit (U, U) is same as the phase of the power supply (8 9 ). (U and 8, U and 9 or ). If the phases are different, you can not get a normal output. ) Main circuit voltage: For to VAC or to VAC Power supply to VAC to VAC /Hz Rapid fuse to V connection to V connection 98 * This is used as a grounding terminal of this unit. Connect it to the protective conductor terminal of the power supply equipment. ) Main circuit voltage: For other voltage than to VAC or to VAC U Power terminals Thyristor regulator Setting input terminals Main unit mounting hole * U Load. Setting Input Terminals ( to ).. Current/voltage input signals ) Without a Current signal ( to madc) to ma ) Manual Voltage signal ( to VDC) Current signal ( to ma DC) Voltage signal ( to V DC) For manual only to ma Manual VLJMH (kω ) AUT. MAN Short to V to V Manual AUT. VLJMH MAN (kω ) Short Manual JLJMH (kω ) Power supply VAC /Hz Transformer /V Rapid fuse 98 * This is used as a grounding terminal of this unit. Connect it to the protective conductor terminal of the power supply equipment. U Power terminals Thyristor regulator Setting input terminals Main unit mounting hole * U Load ) Current signal ( to ma DC) to ma VLJAL (kω ) Voltage signal ( to V DC) to V VLJAL (kω ) 9

9 ) Manual with gradient to ma VLJAL (kω ) Manual VLJMH (kω ) Current signal ( to madc) AUT. MAN. to V VLJAL (kω ) Voltage signal ( to VDC) Manual VLJMH (kω ) AUT MAN ) Output indicator (VL JAM) Current signal ( to madc) Voltage signal ( to VDC) Setter with output indicator (VLJAM) (kω ) Manual (kω ) Output indicator to ma AUT. MAN Setter with output indicator (VLJAM) (kω ) to ma AUT. Manual MAN (kω ) * 9 * Output indicator V V U U U 9 U * 9 only when the power voltage of main circuit is to V and in other voltage. ) units parallel running (without s) Current signal ( to madc) Voltage signal ( to VDC) to ma Short Short Short to V Short Short Short

10 ) units parallel running with gradient s Current signal ( to madc) Voltage signal ( to VDC) to ma to V VLJAL (kω ) VLJAL (kω ) VLJAL (kω ) VLJAL (kω ) VLJAL (kω ) VLJAL (kω ).. Contact input signal Higherlimit connection C H L Higherlimit VLJMH (kω ) Connection of a higherlimit and a lowerlimit C H Lowerlimit Higherlimit L (kω ) (kω ) Higherlimit/lowerlimit (combined type) connection C H L Higherlimit/lowerlimit VLJHL H L Lowerlimit setting Higherlimit setting (kω ) (kω ) Using setting trimmers of this unit only C H L Lowerlimit setting Use the lowerlimit setting trimmer of this unit Higherlimit setting Use the gradient setting trimmer of this unit.

11 . OPERATION. Check Warning Turn the power source before operation to prevent an electric shock accident. Check the connections again. Check the power voltage and the load capacity again. Measure the insulation resistance with a V megger. Short main circuit terminals U and U for the dielectric strength test. This unit becomes hot due to selfcooling type. Make sure to mount the unit with the UP mark ( ) facing upward so as not to interrupt the radiation effect. If the unit is mounted in the direction other than specified, the interior becomes hot to cause a failure or a trouble. Check the control system selection again.. Operation ) In case of auto run Set the set value (SV) of a controller. If an auto/manual selector switch is connected, select it to AUTO. Set the gradient. Make sure that the stable control is executed. Change the parameters (PID constants in particular) of the controller and adjust the gradient setting suitably, if the control is unstable. ) In case of manual run If the auto/manual selector switch is connected, select it to MANUAL. Set a desired output manually. Change the setting manually while monitoring the temperature.. MAINTENACE. Daily Check and Maintenance The checking and inspection of the following points are required to keep this unit run under the best conditions at all times. Items Fastening of bolts and screws on the terminal board Cleaning Contents If the bolts for the main circuit terminals (U, U), in which a large current flows, are loosen, they may be heated to cause wiring damage. If this unit is mounted at a dusty place with conductive dust particles like iron powder, dust particles may attach to the unit to cause a failure or a trouble due to poor insulation. Remove dust particles attached by using a cleaner.. Consumable Parts Don t repair or modify this unit by replacing any parts by other persons than our qualified servicemen. Caution For replacing consumable parts or other parts, please contact your nearest sales agent of CHINO Corporation. Parts names Control PCB Reference exchange intervals to 8 years Working conditions and others The higher the ambient temperature is the shorter the life is. In addition, the life depends largely upon the atmospheric conditions (kinds of gases, kinds and degree of dust particles, etc.).

12 8. ACCESSORIES (Separate purchase is required.) 8. Setter Model VLJAL VLJMH VLJHL Use setting, lowerlimit setting Manual setting, higherlimit setting Higherlimit /lowerlimit setting (Higherlimit/lowerlimit combined type) Specifications Variable resistor kω Variable resistor kω Variable resistor kω (For lowerlimit), kω (For higherlimit) External dimensions Mounting diagram. φ Max φ Weight: Approx. g M9P. Max R φ Max Screw M φ 8 Unit:mm φ. φ Panel cutout 9 8 MIN MIN 8 8 MAX MAX Higherlimit setting trimmer φ(mounting hole) Lowerlimit setting trimmer 8.. Unit:mm 8 Panel cutout Weight: Approx. g Model Use Specification VLJAM Output indicator ( setting manual setting auto/manual selector switch) Voltmeter ( tov or to V) Variable resistor kω, kω Manual setting trimmer Output indicator 9 Unit:mm External dimensions Mounting diagram 9 9 Manual/auto selector switch setting trimmer Panel cutout Weight: approx. g 8. Fuse Unit Model FUJ Model FUJA to JA Applicable current A Applicable current JA:A JA:A JA:A JA:A JA:A Specification Rapid fuse holder Specification Rapid fuse holder with cover φ. (Mounting hole) Mounting hole size φ. M screw Rapid fuse Micro switch 9 Unit:mm Weight: Approx. g Contact signal connection terminal Mounting hole size φ. hole 8. Rapid Fuse Rated Type current A A A A A A PFFU URIC URIC URIC URIC CRLSG Unit:mm Weight: Approx. g 8 M screw (female)

13 9. TROUBLESHOOTING ) Output continues. Check and symptoms Is the load open? Is lowerlimit set to %? Connect the load correctly. Causes and remedial measures Set the lowerlimit to be near % and monitor the condition. If this unit is not restored to normal condition as a result of the above remedial measures, the thyristor element may be defective. Contact your nearest sales agent of CHINO Corporation. ) Output is not proportional to the control input. Check and symptoms Is the lowerlimit set to be high? Is the gradient set to be low? Are the phases of the power supply and main circuit same? Causes and remedial measures Set the lowerlimit to be near % and check the condition. Set the gradient to be near % and check the condition. The phases should be same. Refer to the connection diagram in.. Is the power supply distorted? If the power waveform is distorted, the output is not proportional to the input. Use the power supply having no distorted waveform and check the condition. If this unit is not restored to normal condition as a result of the above remedial measures, the unit may be defective. Contact your nearest sales agent of CHINO Corporation. ) No output Check and symptoms Power lamp (green) does not light. Power lamp (green) lights. Causes and remedial measures Power terminals(8 to )are not connected correctly. Connect them correctly. The main circuit and/or the load are connected correctly. Connect them correctly. The phases of the power supply and the main circuit are not same. The phases should be same. Refer to the connection diagram in.. set to %. Set it to near % and check the condition. Input connections( to terminals)are wrong. Connect them correctly. Input signal is abnormal. Apply normal input signal. Power lamp (green) flickers. Power supply is distorted. Refer to ). If the unit is not restored to normal condition as a result of the above remedial measures, the unit may be defective. Contact your nearest sales agent of CHINO Corporation.

14 . GENERAL SPECIFICATIONS Phase : Single phase Rated voltage : tovac, to AC (V system and V system are selected at terminals.) Allowable voltage fluctuation : % to % of the rated voltage Rated frequency : /Hz (Automatic selection) Allowable frequency fluctuation : ±Hz (operation guarantee) and ±Hz (performance guarantee) of the rated frequency Rated current :,,,,, A AC Input signal : to madc, to VDC or onoff contact signal Input resistance : Ω ( to madc), kω ( to VDC) Output range : to 98% of the rated voltage Minimum load current :.A (at 98% output) Applicable load : Resistive load and inductive load (Transformer primary control: Phaseangle firing system only, Magnetic flux density.t or less) Control system : Phaseangle firing system without feedback Zerocross firing system * Selectable by DIP switches Output setting range : setting... to% of the output range (A setting trimmer is built in.) Lowerlimit setting... to% of the output range (A setting trimmer is built in.) Other functions : Soft start, soft updown ( to seconds variable) Soft start at recovery from momentary interruption Working temperature range : ºC to ºC (Operation guarantee), to ºC (Performance guarantee) Working humidity range : % to 9% RH (No dew condensation is allowable.) Insulation resistance : Minimum VDC, MΩ Between main circuit terminals, power terminals, and power terminals and a case Dielectric strength : V AC minute between main circuit terminals and a case

THREE-PHASE POWER CONTROLLER PA-3000-H3 INSTRUCTION MANUAL

THREE-PHASE POWER CONTROLLER PA-3000-H3 INSTRUCTION MANUAL THREE-PHASE POWER CONTROLLER PA-3000-H3 INSTRUCTION MANUAL - Contents - INTRODUCTION...4 1 FOR SAFE USE OF THIS INSTRUMENT ( Warning)..5 2 CHECKING THE MODEL NUMBER...7 3 INSTALLATION...8 3.1 Installation

More information

Power Controller. (see note 1) 10 sec

Power Controller. (see note 1) 10 sec Power Controller Single-phase Models EUN Series AC Power Controller with Phase-control System Allows Precise Temperature Control Models with Base-up and Soft-start Functions Available EH Series Phase Control

More information

SHIMADEN SINGLE-PHASE THYRISTOR POWER REGULATOR

SHIMADEN SINGLE-PHASE THYRISTOR POWER REGULATOR Shimaden, Temperature and Humidity Control Specialists C %RH SHIMADEN SINGLE-PHASE THYRISTOR POWER REGULATOR approved BASIC FEATURES Easy Front Key Setting compliance A 7-segment LED displays input and

More information

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend Power Controllers GPX Refer to Safety Precautions (page 0). Single-phase Models EUN Series AC Power Controllers with Phase-control System Allow Precise Temperature Control Models with Base-up and Soft-start

More information

Differential Pressure Transmitter

Differential Pressure Transmitter Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused

More information

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake ZJ-267A Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake Instruction Manual Table of Contents Cautions on Safety - - - - - - - - - - - - - - - - - 1 1. Cautions before use - -

More information

35 35A 50 50A 1 Single phase. Solid state power controller

35 35A 50 50A 1 Single phase. Solid state power controller Single Phase, Power Controller Single Phase, Power Controller Features Various and simple input specification DC4-2mA, 1-5VDC, External 24VDC External adjuster (1kΩ) External contact (ON/OFF) Various function

More information

PAC18 Series. Single-Phase Thyristor Power Regulator. Instruction Manual

PAC18 Series. Single-Phase Thyristor Power Regulator. Instruction Manual PAC8 Series Single-Phase Thyristor Power Regulator Instruction Manual Thank you for purchasing a Shimaden PAC8 Series Single-Phase Thyristor Power Regulator. After making sure the product fits the desired

More information

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS CP-UM-306E ECM3000 Control Motor User's Manual WARNING Be sure to turn the power OFF before mounting, removing, or wiring the ECM3000 or opening the cover. Touching electrically charged parts such as power

More information

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase) SRPH1 Series Single Phase, Analog Input Type SSR Features Power control/ Cycle control/phase control (fixed cycle/ variable cycle) are available with 4-mA analog input Superior dielectric strength : 4,000VAC

More information

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,

More information

EDDY CURRENT VARIABLE SPEED DRIVE CONTROLLER - TYPE PM-07

EDDY CURRENT VARIABLE SPEED DRIVE CONTROLLER - TYPE PM-07 EDDY CURRENT VARIABLE SPEED DRIVE CONTROLLER - TYPE PM-07 When properly installed, operated and maintained, this equipment will provide a lifetime of optimum operation. It is mandatory that the person

More information

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual 11-M61E TABLE OF CONTENTS HANDLING & MAINTENANCE Storage 1 Transport 1 STANDARD ENVIRONMENT 1 INSTALLATION AND CONNECTION

More information

POWER REGULATOR LD -40PSU

POWER REGULATOR LD -40PSU JZ99D4121A AMPIFIRE AMPIFIRE TYPE D-4PSU ZJ-46A ISTRUCTI MAUA Manual number JZ99D4121 Sub number A Date of preparation ov. 2 Thoroughly read this instruction manual, and then use the unit correctly. Especially,

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

MODEL UC 14YFA. Hitachi. Power Tools TECHNICAL DATA AND SERVICE MANUAL CHARGER UC 14YFA SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT

MODEL UC 14YFA. Hitachi. Power Tools TECHNICAL DATA AND SERVICE MANUAL CHARGER UC 14YFA SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT MODEL UC 14YFA Hitachi Power Tools CHARGER UC 14YFA TECHNICAL DATA AND SERVICE MANUAL U LIST No. F888 Aug. 2003 SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT CONTENTS Page 1. PRODUCT NAME...1

More information

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

ECON ELECTRIC ACTUATOR Fig ELA60 Ex ECON ELECTRIC ACTUATOR Fig. 7907, type ELA60 Fig. 7907 ELA60 IP67 (optionally IP68) Fig. 7907 ELA60 Ex EX ǁ 2G Ex d IIB T4 Gb Small & Compact quarter turn actuator Mechanical position indicator High output

More information

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller Technical Guide for Power s CSM_Power_s_TG_E_5_1 Overview of Power s Example of Combining Different Types of Heater Control Heater control Manual G32X-V2K E5@ series Current output Current output Voltage

More information

INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B

INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES PBA20-12 PBA20-24 OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B68-0175-00 About Brands and Trademarks Our company and product names described

More information

Model Number Structure

Model Number Structure Conductive Level Controller CSM DS_E_1_1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at or using self-holding circuits. Sensitivity adjustment of operating

More information

EX Series. Electric Actuators for Ball and Butterfly Valves

EX Series. Electric Actuators for Ball and Butterfly Valves EX Series Electric Actuators for Ball and Butterfly Valves Next-Generation Electric Actuator Realization of Upgraded General-Purpose Actuators The modularization and adoption of the common parts have brought

More information

EX Series. Electric Actuators for Ball and Butterfly Valves

EX Series. Electric Actuators for Ball and Butterfly Valves EX Series Electric Actuators for Ball and Butterfly Valves Next Generation Electrical Actuator Realization of Upgraded General-Purpose Actuators The modularization and the adoption of common parts have

More information

Air duct switching damper

Air duct switching damper English LOSSNAY HEAT RECOVERY VENTILATOR SYSTEM COMPONENT Air Duct Switching Damper MODEL P-133DUE-E Applicable Model VL-220CZGV-E Air duct switching damper Contents 1. Safety Precautions 2 2. Outside

More information

THV-40SERIES. Power Controller. Single Phase Thyristor Unit (High Voltage Type) AC V. RoHS compliant

THV-40SERIES. Power Controller. Single Phase Thyristor Unit (High Voltage Type) AC V. RoHS compliant THV-4SERIES Power Controller Single Phase Thyristor Unit (High Voltage Type) C38-48V CE marking : specified noise filter must be used. RoHS compliant E RC LM + V 4-2m - N L RC LM 1 2 + V 4-2m - N L Designed

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Instruction Manual Model 2831D 4 ½ Digit True RMS Digital Multimeter 1 1. PRODUCT DESCRIPTION 1-1. Introduction Thank you

More information

Transmitter CSA-591 Instruction Manual

Transmitter CSA-591 Instruction Manual Transmitter CSA-591 Instruction Manual EN294-1141-F FOREWORD Thank you very much for your purchasing our Transmitter CSA 591. This manual explains installation procedures and connecting method and also

More information

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS NB 0811 - NB 1511 NB 0831 - NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS LEN.MAN.UPS.069 Rev.2.00/2002 CONTENTS Safety Instructions 1 Introduction 3 2.1 FEATURE 3 2.2 UPS modules 4 How the UPS works 5 3.1

More information

DC POWER SUPPLY ALIMENTATION C.C.

DC POWER SUPPLY ALIMENTATION C.C. DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify

More information

Technical data. WARNING! Residual voltage is present for 1 minute after disconnecting mains voltage.

Technical data. WARNING! Residual voltage is present for 1 minute after disconnecting mains voltage. INSTALLATI Speed-controlled drive system manufacturer EMS Model Units included S for rotary heat exchanger EURA, size 20 60. Page Content 1 Technical data 1 Units included............motor, Control unit

More information

PAC18 Series. Single-Phase Thyristor Power Regulator. Instruction Manual

PAC18 Series. Single-Phase Thyristor Power Regulator. Instruction Manual PAC8 Series Single-Phase Thyristor Power Regulator Instruction Manual Thank you for purchasing a Shimaden PAC8 Series Single-Phase Thyristor Power Regulator. After making sure the product fits the desired

More information

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL Terminal Relay Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent

More information

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL. High Load Relay for Smart Junction Box TL RELAYS High heat-resistant type: Sealed Pin in Paste compliant type: Flux tight New 14.4.7 11.433 1.3 FEATURES Large capacity switching

More information

I. Safety precautions

I. Safety precautions . Safety precautions The items described in these instructions and on the inverter itself are very important so that you can use the inverter safely, prevent injury to yourself and other people around

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Wide selections of actuators, terminals and bodies to meet any application Excellent environmental resistance Die casting caseiec IP67 Plastic caseiec

More information

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4 Braking Resistor Units 3G3IV-PCDBR2 B/4 B Braking Units Thank you for choosing an OMRON Braking Resistor Unit and Braking Unit. Proper use and handling

More information

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c Series Single phase, Analog input type SSR Features Power control/ Cycle control/phase control (fixed cycle/ variable cycle) are available with 4-mA analog input Superior dielectric strength : 4,000VAC

More information

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual DC power supply connect to VF-AS1/PS1 Optional initial charger Instruction manual NOTE 1. Make sure that this instruction manual is delivered to the end user of the optional initial charger. 2. Read this

More information

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm DC2-wire Square Proximity Sensors FL2R/SSeries This DC2-wire Square Proximity sensor Can Be Directly Connected to Programmable Controllers and Units. Wide Range of Models Available. Reduced wiring costs

More information

PAC27 THYRISTOR TYPE SINGLE PHASE POWER REGULATOR. Instruction Manual

PAC27 THYRISTOR TYPE SINGLE PHASE POWER REGULATOR. Instruction Manual PAC27 THYRISTOR TYPE SINGLE PHASE POWER REGULATOR Instruction Manual Thank you for purchasing this Shimaden product. Please check that the delivered product is exactly what you ordered. Please do not begin

More information

Portable Instruments. Bulletin 2000-E

Portable Instruments. Bulletin 2000-E Portable Instruments Bulletin 2000-E Usage Precautions Warning: Indicates usage precautions that must be read to ensure the safety of users and the equipment. Safety Instructions for Portable Instruments

More information

DRB-1 Series Instruction Manual

DRB-1 Series Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol DC Motor Speed Control Boston Gear Ratiotrol DC Motor Speed Control P-3017-BG Doc. No. 60007 Installation and Operation DCX plus Series II Enclosed Models 1/12-1 HP a division of Altra Industrial Motion Contents l General Information

More information

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev / SSP-7080 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing USER MANUAL Rev.1.1 2007/04 7673-7080-0000 CONTENTS Warning, Cautions and Operating Conditions P.1 Introduction

More information

Switching DC Power Supply

Switching DC Power Supply 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary

More information

Model Number Structure

Model Number Structure Power Relay G7J Electromechanical Relays A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive

More information

DRL-1 Series Instruction Manual

DRL-1 Series Instruction Manual DRL-1 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit

More information

PSU-S-12V/L-1A/5/FTA/PTC-TR-MC AWZ v.1.0

PSU-S-12V/L-1A/5/FTA/PTC-TR-MC AWZ v.1.0 PSU-S-12V/L-1A/5/FTA/PTC-TR-MC AWZ 05121 v.1.0 Linear, stabilized power supply unit. Edition: 1 from the 2 nd February 2011 Supercedes edition: Features of the power supply unit: five outputs protected

More information

LS200 Series Instruction Manual

LS200 Series Instruction Manual LS200 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage may lead to an electrical shock, damage to the unit

More information

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation User s Manual 700938 Power Supply Yokogawa Electric Corporation 3rd Edition Introduction Revisions Thank you for purchasing the 700938 Power Supply. This Instruction Manual contains useful information

More information

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 1410 90W DC Power Supply User Manual Safety Summary The following safety precautions

More information

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety... Contents 1 Introduction...1 2 Safety...4 3 Product Specifications...6 Outdoor UPS User Manual 4 Installation...8 4.1 Inspection...8 4.2 Installing the UPS Cabinet...8 4.3 Connecting the Power Supply...10

More information

VF-S11 RS485 built-in board option RS4003Z Instruction Manual

VF-S11 RS485 built-in board option RS4003Z Instruction Manual VF-S11 RS485 built-in board option RS4003Z Instruction Manual NOTICE 1. Make sure that this instruction manual is delivered to the end user of RS485 built-in option board. 2. Read this manual before installing

More information

SCR Power Controllers

SCR Power Controllers SCR Power Controllers Instruction Manual SCR POWER CONTROLLERS TABLE OF CONTENTS General Description and Specifications...1 Firing Modes....2 Installation and Wiring...4 Operation...9 Troubleshooting...15

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible

More information

Three Phase Power Controller THW-A Series

Three Phase Power Controller THW-A Series THW Three Phase Power Controller THW Series General Description Three phase power controller has an LED display to show set values and input signals and front keys for easy setting and monitoring. Loaded

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves

Operation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves Document No.: KE-4041-00 Operation Manual KITZ EKSR Series Spring Return Type Electric Actuators For KITZ Ball Valves Thank you for choosing KITZ products. For safe and trouble-free function and performance

More information

TECHNICAL DATA Troubleshooting Tips for DC to DC Converter

TECHNICAL DATA Troubleshooting Tips for DC to DC Converter When power supplies do not function properly, please check the following troubleshooting table before returning a unit. If the power supply still has a problem, please contact the designated distributors

More information

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W) CIRCUIT-TEST Switching Mode Power Supply with Remote Sensing PSC-9800 0-16V 5A / 0-27V 3A / 0-36V 2.2A (80W) OPERATION MANUAL 1 2 PSC-9800 08R14 Contents Safety Precautions...page 4 Introduction... 5 Controls

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

Triple Output Power Supply

Triple Output Power Supply Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Model 1672, 1673 Triple Output Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions

More information

HL (AZH) LIMIT SWITCHES

HL (AZH) LIMIT SWITCHES COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount

More information

EISHO TEK. Vacuum Circuit Breaker

EISHO TEK. Vacuum Circuit Breaker EISHO TEK Vacuum Circuit Breaker TYPE:SV1-12 INSTRUCTION MANUAL Operation and Maintenance Version TAIWAN CALSONIC SAFETY PRECAUTIONS For safety reason, this equipment should be handled by personnel who

More information

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary drops up to % of rated. Wide-range AC-activated coil that handles 1 to 1 or to

More information

No Operation of air conditioner Explanation

No Operation of air conditioner Explanation 12. Troubleshooting 12-1 Items to be checked first 1. The input voltage should be rating voltage ±10% range. The air conditioner may not operate properly if the voltage is out of this range. 2. Is the

More information

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide

More information

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.) CSM_A165S_W_DS_E_4_1 Separate Construction with Cylindrical 16-dia. Body Same separate construction as the A16-series Pushbuttons with Miniature

More information

High-power Solid State Relays G3PH

High-power Solid State Relays G3PH New Product News High-power Solid State Relays G3PH High-power, Load-control s with High Current of 75 or 150 A and High Voltage of 240 or 480 VAC RoHS compliant. Models also available with no zero cross.

More information

VAL6 Infrared Heater KBE5S & KBE5L. (2-step) Maintenance Manual

VAL6 Infrared Heater KBE5S & KBE5L. (2-step) Maintenance Manual VAL6 Infrared Heater KBE5S & KBE5L (2-step) Maintenance Manual Wiring Diagram of Burner Control KBE5S KBE5L 2-step Sequence Time Chart Operation Switch ON ignition OFF Fan Igniter Solenoid Pump 5 sec.

More information

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0 PRO POWER 2 0 A L I T H I U M B AT T E RY C H AR G E R M O D E L : P P - L B C - 1 2 2 0 V E R S I O N : V 1. 0 Contents 1. Revised History... 1 2. Warning... 1 3. Notes... 1 4. Product Number System...

More information

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL 72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com

More information

A1P OPERATING MANUAL

A1P OPERATING MANUAL A1P OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty...

More information

M100F Incremental Motor Actuator R81F Interface Board

M100F Incremental Motor Actuator R81F Interface Board Installation Sheets Manual 121 Motor Actuators Section M Technical Bulletin M100F Issue Date 0493 M100F Incremental Motor Actuator R81F Interface Board Application Details Figure 1: M100 Motor Actuator

More information

ELECTRONIC CONTROL ACTUATOR

ELECTRONIC CONTROL ACTUATOR ELECTRONIC CONTROL ACTUATOR Nucom Series LINEAR TYPE Nucom L50S OPERATION MANUAL Koei Industry Co., Ltd. FOR YOUR SAFETY In order for better and safety use of the product for a long period, please observe

More information

User s Manual Power Supply IM E. 5th Edition

User s Manual Power Supply IM E. 5th Edition User s Manual 700938 Power Supply 5th Edition Thank you for purchasing the 700938 Power Supply. This user s manual contains useful information about the instrument s functions and operating procedures

More information

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance

More information

HBLT-C1 Controller. Instruction Manual. For pump control of levels in industrial refrigeration systems

HBLT-C1 Controller. Instruction Manual. For pump control of levels in industrial refrigeration systems Instruction Manual HBLT-C1 Controller For pump control of levels in industrial refrigeration systems Instruction manual HBLT-C1 Controller (006-UK) 1 / 14 Table of Contents Safety Instructions... 3 Introduction...

More information

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN Form 1254 BRAKETRON Electronic Motor Brake Instructions SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN TABLE OF CONTENTS SECTION TITLE PAGE I. Introduction 1 II. Specifications 1 III. Principles

More information

OPERATING AND MAINTENANCE INSTRUCTIONS. Generator Models SXA1900HX, SXA2800HX,SXB2800HX SXB4000HX, SXB5500HX(S), SXB7000HX(S)

OPERATING AND MAINTENANCE INSTRUCTIONS. Generator Models SXA1900HX, SXA2800HX,SXB2800HX SXB4000HX, SXB5500HX(S), SXB7000HX(S) GASOLINE POWERED PORTABLE GENERATORS OPERATING AND MAINTENANCE INSTRUCTIONS Generator Models SXA1900HX, SXA2800HX,SXB2800HX SXB4000HX, SXB5500HX(S), SXB7000HX(S) JOHN BROOKS COMPANY LIMITED TORONTO - MONTREAL

More information

Indoor Linear 50W Driver SI-CU WW

Indoor Linear 50W Driver SI-CU WW Product Data Sheet Rev.2.0 2016. 5. 27 1# LED Driver Indoor Linear 50W Driver SI-CU1425001WW Constant Current LED Driver Features & Benefits Output Current Range: 500~1400 ma (adjustable via R-set) Output

More information

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator) Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator) Linear Actuator with Type 3260 Control Valve Rotary actuator with lever system Linear actuator with Type 3321 (V2001) Control

More information

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force. Tactile Switch A Wide Range of Models: 6 x 6 mm, 1 x 1 mm, Vertical, and High-force. A positive click action plus a long life equal to that of a no-contact switch. Radial models (taping specifications)

More information

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CONTENTS PRM-2 & PRM-3 1. Warranty...3

More information

DC2-Wire Unshielded Cylindrical Proximity Switches

DC2-Wire Unshielded Cylindrical Proximity Switches DC2-Wire Unshielded Cylindrical Proximity Switches FL7M Series Unshielded switches achieve especially long sensing distances Long sensing distance (2 times the sensing distance of a regular FL7M) DC2-wire

More information

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3 Atlantic Battery Systems 1065 Market Street Paterson, NJ 07513 Phone: (800) 875-0073 Fax: (973) 523-2344 sales@atbatsys.com www.atbatsys.com SOS1 SOS2 SOS SERIES Spares On Site Battery Cabinet Installation

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

Extended Panel Operation Manual RKP001Z-0

Extended Panel Operation Manual RKP001Z-0 Extended Panel Operation Manual RKP001Z-0 Table of Contents 1. NAMES AND FUNCTIONS OF MAIN PARTS...3 2. CONNECTION AND START-UP...4 3. DIMENSIONS...5 4. PROTECTION FUNCTION...6 5. SPECIFICATIONS...6 6.

More information

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations Solid State Relays G3RV Slimmest OMRON plug-in SSR with maximum width 6.2 mm Long electrical life and high speed switching Large plug-in terminals for reliable connection G3RV-D (DC load) models can manage

More information

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY EB RELAYS (AEB) (1A type) FEATURES Compact and high capacity using double contacts in series and permanent magnet installed. (1,A/3 times)

More information

Welding Positioner Model: LD-60R/150R/300R

Welding Positioner Model: LD-60R/150R/300R Welding Positioner Model: LD-60R/150R/300R Operating Instructions IMPORTANT Carefully read and understand these operating instructions, as well as instructions for operating ancillary equipment, before

More information

Model Number Structure

Model Number Structure Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can

More information

User Manual of 2MA2282

User Manual of 2MA2282 ECG-SAVEBASE EMAIL:EBAY@SAVEBASE.COM WEB: HTTP://STORES.EBAY.CO.UK/SAVEBASE User Manual of 2MA2282 High Performance Microstepping Driver ECG-SAVEBASE ECG Safety Statement Easy Commercial Global is not

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

SYSDrive Frequency Inverter

SYSDrive Frequency Inverter SYSDrive Frequency Inverter T V/f control T PID control T Standard LED, optional LCD operator T Fieldbus options: DeviceNet T 7 configurable digital inputs T 3 configurable digital outputs T Low audible

More information

10V. the rack of the oil pump must be on the

10V. the rack of the oil pump must be on the P.E.D 20.. ESG2002 series ELECTRONIC GOVERNOR INSTRUCTION A1000C-W ELECTROMAGNETIC ACTUATOR Before inst al l el ectromag neti c, p lea se inspect that the rack of the oil pump shouldn' t be stuck in any

More information

MX431 Generator Automatic Voltage Regulator Operation Manual

MX431 Generator Automatic Voltage Regulator Operation Manual Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator 1 1. SPECIFICATION Sensing Input Voltage Frequency 190 ~ 264 VAC Max, 1 phase, 2 wire 50 / 60 Hz, selectable

More information

MS Application. Features. Proportional Valve Actuator General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and

More information