1 November 12, 2010 Detex Corporation, 302 Detex Drive, New Braunfels, Texas (830) / / Fax (830) detex@detex.com INTERNET: INSTALLATION INSTRUCTIONS FOR DETEX VALUE SERIES V40 RIM PANIC HARDWARE, FV40 RIM FIRE EXIT HARDWARE AND "H" MODELS (HURRICANE) - "W" WEATHERIZED FV40/ V40 x EB x W V40 x EX x W Exit Device Parts Check List Centercase/Pushpad SubAssembly Plastic Template Use for ease of installation Fillerplate SubAssembly Endcap P/N: L9 = Less 9v Battery SI = Status Indicator "ON" Endcap Bracket P/N: P/N: Mounting plate Subassembly P/N: Centercase Cover P/N: Strike *, P/N: Pushpad Wrap P/N: X (3-0) P/N: X (4-0) Fillerplate SubAssembly (EB x W) P/N: (3-0) P/N: (4-0) Fillerplate Subassembly (EX x LD) Hex Nut P/N: V Battery P/N: PP-5567 Non-Roller Strike Strike Shim Standard Plastic Template P/N: (3-0) P/N: (4-0) P/N: P/N: P/N: Fillerplate SubAssembly (EX x HD) Hex Key P/N: Strike *, P/N: P/N: (3-0) P/N: (4-0) Mortise Strike P/N: Mortise 2" Narrow Stile Strike Shim Plastic Template P/N: P/N: Fillerplate SubAssembly (EX x CD) P/N: (3-0) P/N: (4-0) Hex Nut P/N: Strike Shield P/N: Note: Parts listed above will vary according to product configuration. *Narrow Stile "NS" option Mortise cylinder not included with device. Standard Yale type cam required. U.S. PATENT NUMBERS: B B2 INTERNATIONAL PATENT NUMBER: PCT Owner's Copy See Optional Accessories For: - Glass Bead Kit - Sex Nuts - Tamper Kit - Double Door Strike Kit - Key Stop Kit - Narrow Stile Kit Page 1

2 !!!CHECK BEFORE STARTING!!! Wide Stile (Surface Strike) Minimum door stile 4-1/2" (114 mm) Template drawings provide door and frame structural and dimensional specifications for door and frame preparation. Doors and frames with walls having a structural thickness (metal skin plus reinforcement, or solid wood) to engage less than (3) full screw threads, are considered unreinforced for hardware. Unreinforced Doors: Use Sex Nuts and Bolts Unreinforced Frames: Use Blind Rivet Nuts (see sketch) Fasteners for unreinforced openings are not supplied by Detex. Narrow Stile Minimum door stile 2" (51mm) Surface strike possible Mortise strike recommended Reinforced door or frame engages at least (3) screw threads. Reinforcement Door Skin Blind Rivet Nut X X X X Door Must Swing Freely Door Must Not be Warped Door Must Not Bind Door Must Not Sag NOTE: 750mm MAXIMUM DOOR WIDTH OPENING FOR EUROPE FOR 36" DEVICE (1000mm MAXIMUM DOOR WIDTH OPENING FOR EUROPE FOR 48" DEVICE) THE SAFETY FEATURES OF THIS PRODUCT ARE ESSENTIAL TO ITS COMPLIANCE WITH EN NO MODIFICATION OF ANY KIND, OTHER THAN THOSE DESCRIBED IN THESE INSTRUCTIONS ARE PERMITTED. RHR Door LHR Door Horizontal Reference Stop Face LC Mullion Face 40" Finished Floor RHR Door Inside Face LHR Door Inside Face Page 2

3 Drill Bit Fastener Table Tap Wrench Comments Use Either Machine Screws, Sheetmetal Screws, or Sex Nuts Machine Screws #6-32 x 5/8" PPH #36 or 7/64 #6-32 Tap Used on 98 Strike Shield Mounting Holes #6-32 x 3/8" PPH Used to Mount Centercase Cover and Endcap #10-24 x 5/8" PPH #25 or 9/64" #10-24 Tap Used on 99 Strike Center Mounting Hole #1/4-20 x 1/4" PPH Used to Fasten Centercase Unit onto Mounting plate #1/4-20 x 1" PPH #7 or 13/64" #1/4-20 Tap Used on Strike, Mounting plate, and Endcap Mounting Holes Sheetmetal Screws #6 x 1" PFH 9/64" Used on 98 Strike Shield Mounting Holes Self-drilling Screws #10 x 1" #14 x 1" PFH PPH No pilot hole necessary for self-drilling screws Used on 99 Strike Center Mounting Hole Metal Applications Used on Strike, Mounting plate, and Endcap Mounting Holes Sex Nut #1/ /32" Interior Door Face 3/8" Exterior Door Face Recommended on Fire Rated Wood and Unreinforced Hollow Metal Doors Used on Mounting plate and Endcap Mounting Holes # /64" Interior Door Face 5/16" Exterior Door Face Recommended on Fire Rated Wood and Unreinforced Hollow Metal Doors Used on Strike Hook Mounting Holes Note: (1) Fastener selection will vary per catalog configuration and kits ordered. (2) Mortise Cylinder NOT Provided. Tools Required Power Drill Pencil Hack Saw Safety Glasses Hammer Level Tape Measure Screw Driver Center Punch Page 3

4 For GATE installation see GATE INSTALLATION EXAMPLE page 2 1 Slide 99 strike locator into mounting plate. (if using a 98 strike, see 98 STRIKE INSTALLATION page) Strike holes Mounting plate hole 3 If necessary, remove label temporarily to mark trim hole 4 Mounting plate Hole Mark mounting plate and strike holes Punch marked holes 5 RECOMMENDED Mark centerline for unit 40 inches above finished floor Strike holes (2) For 1/4-20 machine screws drill #7 holes No pilot hole necessary for #14 self-drilling screws (see fastener table) Mounting plate holes (2) For 1/4-20 machine screws drill #7 holes. Trim input hole For #14 self-drilling screws no pilot holes if necessary. necessary. (see outside trim instructions) For sex nuts drill 3/8" holes. (see fastener table) 6 Fasten tightly with lockwashers and 1/4-20x1" machine screws or #14 self-drilling screws Fasten loosely with two 1/4-20x1" machine screws or #14 self-drilling screws Page 4

5 Position cam as shown Insert centercase into slots of centercase mounting plate, depress pushpad, rotate toward door. DOOR 1 2 Fasten rim device to mounting plate with 1/4-20 x 1/4" PPH MUST BE INSTALLED! Peel off backing to expose tape. 3 IMPORTANT: Install Pushpad Wrap. Verify wrap is secured by snapping in place. When using Pushpad Wrap with text verify handing before installing wrap. (LHR handing shown) Page 5

6 CHECKING FOR DEVICE CLEARANCE (Cut-Off procedure if required) 1 Slide endcap assembly onto extrusion 2 Align fillerplate FLUSH to extrusion prior to cutting Secure with tape Type EB x W 36" Unit 2 in Length 48" Unit 8 in 3 Install battery (where required) CAUTION: Check for device & door frame clearance. If no cut-off needed, proceed to MORTISE CYLINDER INSTALLATION Protect wires during cutting EX x W 6 in 12 in Cut fillerplate & extrusion to desired length* Procedures for Maximum Cut Down Lengths Caution Required-Special Handling (Call factory at (800) for assistance) 1 2 Secure with tape Align fillerplate FLUSH to extrusion prior to cutting Max. Cut-Off Length (L) inches 36" Unit 4" 48" Unit 10" REMOVE electronics prior to cut down Protect wires during cutting Cut fillerplate & extrusion to desired length* Battery Reassemble electronics after cutting. Electronics may extend beyond edge of cut fillerplate. REMOVE battery clip for CUT-OFF lengths longer than standard cut-off length Place battery in endcap. Battery should not contact circuit board Page 6

7 MORTISE CYLINDER INSTALLATION 1 Wave Washer (Detex p/n: ) Cylinder collar optional (Detex p/n: ECL-1595) Wave Washer (Detex p/n: ) Longer cylinder (see note 3) Install mortise cylinder with hex nut provided CAUTION: Tighten with hand tools only. Do not overtighten Adjust for LONGER cylinder length with spacers (provided) and cylinder collar (not included), if needed. NOTE: (1) All cylinder spacers must be used. (2) Turn key max CCW before installing slide in fillerplate. (3) Use a cylinder collar when installing a 7-pin mortise cylinder. (4) Reinstall fillerplate subassembly Refer to switch options pages Page 7

8 1 2 Slide fillerplate & endcap bracket into extrusion & level pushpad assembly. Note: Endcap Bracket must bottom-out on extrusion. DO NOT REMOVE NYLON SPACER ON BACK OF BRACKET! 3 With pushpad assembly level, secure the endcap bracket to door by tightening the factory installed self-drilling screw. 4 For 1/4-20 machine screws drill #7 holes. For #14 self-drilling screws no pilot holes necessary. For sex nuts drill 3/8" holes. see HARDWIRE TRANSFER OPTIONS page IMPORTANT: Install (2) 6-32 FH Screws for added security 5 Slide and mount endcap to endcap bracket with two 1/4-20x1" PPH machine screws or #14 self-drilling screws. DO NOT OVERTIGHTEN Page 8

9 For Hurricane Models (see Hurricane kit) 1 Fasten rim device to mounting plate and door with 1/4-20x1" machine screws(drill #7 holes) or #14 self-drilling screws 2 Align the 99 strike with the latchbolt. Firmly tighten screws (use shim if necessary) Deadlatch 99 strike 3 Note: Check device function and strike engagement BEFORE marking and drilling for center screw. Mark and drill center hole. 9/64" for machine screws. No pilot hole necessary for #10 self-drilling screws. (see fastener table) Secure the 99 strike. 4 Care and Maintenance: The Detex Value Series devices are designed to provide many years of maintenance free service under normal usage. Periodically inspect and lubricate the unit to extend its life. Install cover with 6-32 machine screws. Tighten with hand tools only Page 9

10 Status Indicator Off * On SWITCH OPTIONS Switch selections must be made before installing battery (See Figure 1) Table 1 Status Description The Device gives no indication of armed or disarmed status. The Device flashes red or green LED every 3 seconds. Red indicates armed status and green indicates disarmed. See Table 2 Figure 1 Selector switches detail Disable Auto rearm On * Off Table 2 Auto Rearming Feature Setting Alarm sounds until turned off with key. Extended bypass is enabled. Unit sounds alarm for 2 minutes after bar is released. Alarm will automatically rearm after 2 minutes Table 3 Remote Signal Remote Bypass Brown Common Violet N.O. contact Yellow Gray-Green Normally Open Normally Closed Violet ---- N.O. contact ---- Contacts rated at 30VDC or 125VAC (EB x W shown) Selector switches See Table 1 ON ON STATUS Disable INDICATOR AUTO REARM * Factory default settings: STATUS INDICATOR switch set to "OFF" Disable AUTO REARM switch set to "ON" Remote signal (optional) Remote bypass Battery connector (standard) Fillerplate subassembly Protect wires to avoid pinching V40 EXxW & EXVxW Wiring Assemblies Endcap bracket Endcap Install armored cable kit (if required) EX, EXxW (0.1A) for signaling applications EXV (3A), EXVxW (5A) for power applications Wire Color Connection Wire Color Connection Brown Gray Yellow Common Closed Open Brown/Red Gray/Red Yellow/Red Common Closed Open Page 10

11 L9SI SWITCH OPTIONS L9 = Less 9v battery SI = Status indicator Disable Auto Alarm Switch selections must be made before applying power. Status Indicator Disable Auto rearm Disable Low Battery On On Jumper L9SI factory presets The Device flashes red or green LED every 3 seconds. Alarm sounds until turned off with key. (No battery or leads on device) ON ON Disable AUTO REARM STATUS INDICATOR Table 3 Remote Signal Remote Bypass Brown Common Violet N.O. contact Yellow Normally Open Violet N.O. contact Gray-Green Normally Closed Contacts rated at 30VDC or 125VAC Status Figure 1 Protect wires to avoid pinching Remote signal Remote bypass TRANSFORMER DETEX BE-961-X Battery eliminator. Must be ordered separately Black Red To Panic Device Red Positive Black Negative Page 11

12 HARDWIRE TRANSFER OPTIONS (Requirements: Minimum 6 Conductor Wires, Maximum 12 Conductor Wires) Electric Hinge Order by finish p/n: EWH8-X Electric Hinge Endcap Prep Wire chase through door Power Transfer p/n: PT-5 Power Transfer Endcap Prep Wire chase through door 1/2" Hole through the inside door face 1/2" Hole through the inside door face Note: For high traffic areas an electric through-wire hinge or power transfer is recommended. Value Series Weatherized Flex Conduit/End Cap Kit Catalog #: FCV-W-3 or FCV-W-10 p/n: or Adjust for handing (LHR shown) Fasten securely Drill 7/8" Hole Through Center Guide Note: (1) Use enclosed waterproof wire connectors. Note: For high traffic areas an electric through-wire hinge or power transfer is recommended Page 12

13 ALARM OPERATIONS Refer to switch options pages PushPad = On = Off Red LED Siren (LHR shown) Device features Mortise Cylinder Green LED SPECIAL NOTES and DEFINITIONS: 1. When operating the ON/OFF switch, there is a slight delay. 2. The key is inserted and removed only in the horizontal position (home position). 3. Key function: counter clockwise (CCW) = Armed; clockwise (CW) = Disarmed. 4. The power needs to be removed to register changes in the slide switches. a. Status Indicator (This will affect battery life) b. Disable Auto Rearm 5. Arming delay mode and auto rearm timers vary by order. UNIT ARMING TEST: 1. Turn key counterclockwise (CCW) (key is removable after rotating back to horizontal position). 2. Red LED will flash twice, then green LED will illuminate for the 15 second delay time, then turn off. The siren will sound three short beeps indicating the unit is armed. 3. Depress Pushpad (Siren will sound and red LED will illuminate). 4. Turn key clockwise (CW). Turns alarm off. LOW BATTERY ALERT: 1. Siren will beep and red LED will blink at approximately 45 second intervals when battery is low. DOGGING FEATURE: (non-fire rated units only) 1. Depress Pushpad. 2. While holding Pushpad depressed, turn key clockwise (CW). Pushpad should remain depressed (Key is removable after rotating back to horizontal position). 3. Unit is now disarmed. STATUS INDICATOR: 1. Slide the switch to ON and apply power. 2. If the unit is armed, the red LED will blink every 3 seconds. 3. If the unit is disarmed, the green LED will blink every 3 seconds. Disable AUTO REARM (Off): 1. When the unit is in full alarm and the bar is released, the alarm will shut off after 2 minutes. Care and Maintenance: The Detex Value Series devices are designed to provide many years of maintenance free service under normal usage. Periodically inspect and lubricate the unit to extend its life Page 13

14 V40xEBxW Troubleshooting Tips for Default Setting PROBLEM PROBABLE CAUSE ACTION When unit is armed, red LED flashes twice, green LED is on for 15 seconds, but the unit does not give three beeps after the green LED goes off. The actuator is sticking to the micro switch. Verify plastic actuator is functioning correctly. Check spring on actuator. No LED activity when key is turned ccw to armed position. Gives a low battery indication. LED's do not flash to indicate armed or disarmed status. Battery connector missing Dead or weak battery. Battery not secured to connector correctly. Battery connector or wires damaged. No external power. Low battery. Status indicator switch in off position. L9 option ordered Install new battery, LED's should flash and the siren beep once. Secure battery correctly. Call Detex Check for loose connections or power turned off. LED's should flash and the siren beep once. Install new battery, LED's should flash and the siren beep once. Remove battery power from unit. Slide 'Status Indicator'switch to 'ON' position. Reinstall battery. (or if L9 option ordered) Turn power to unit off. Slide status indicator switch to the ON position. Reconnect power. Battery connector not supplied with L9 option. Technical Support Page 14

15 98 Strike locator 98 STRIKE INSTALLATION (when required) Align the strike with the latchbolt. Firmly tighten screws Door frame Shield (if necessary) Shim (if necessary) 98 Strike Cutout per 98 Strike Mark and drill holes as necessary. #7 for 1/4-20 machine screws, For #14 self-drilling screws, no pilot hole necessary. 7/64" for 6-32 machine screws, 9/64" for #6 sheetemtal screws (see fastener table) STRIKE HOOK INSTALLATION (Caution: This installation is required on fire rated door openings with removable mullion.) Door Door Strike hook Door 99 strike Mullion post For mounting hole locations use Strike Locator (Template) provided. DRILL CHART Machine screw #10 Sheetmetal screw #25 or 9/64" tap #22 or 5/32" pilot hole Page 15

16 GATE INSTALLATION EXAMPLE (Actual installation will vary) Gate Stop (see table) Weld recommended, machine or sheetmetal screw mounting allowable. Strike plate perpendicular to device plate Weld recommended, machine or sheetmetal screw mounting allowable. Detail A 3/4" Max. See Detail A See Detail B Plate for mounting V40 x W panic device (see table) Plate for mounting door strike (see table) LC Detail B Weld recommended, machine or sheetmetal screw mounting allowable. 40" above finished floor Plate Location Gate Strike Recommended Plate Size Thickness (Min.) 1/8" thick plated, galvanized, or painted steel OR 1/4" thick aluminum plate 1/8" thick plated, galvanized, painted steel plate, angle iron, or 1/4" thick aluminum plate Height (Min.) 10" 5" Stop 1/8" thick plated, galvanized, or painted angle iron OR 1/4" thick aluminum angle plate 2" Page 16

17 Glass Bead Kit Catalog No: GB2 - Glass Bead Kit, 40 series p/n: Optional Accessories #1/4-20 X 1-1/2" Screw (4) Included Flex Conduit Kit Catalog No: FCV-W-3 or FCV-W-10 Waterproof Connectors Provided Sex Nut The #10-32 kit is available in (4) finishes: Catalog No: SN2 Brushed Brass BHMA 606 Finish Catalog No: SN2 Oil Rubbed Bronze BHMA 613 Finish Catalog No: SN2 Brushed Chrome BHMA 626 Finish Catalog No: SN2 Stainless Steel BHMA 630 Finish p/n: X Tamper Kit (Security Kit) Catalog No: SSK3 p/n: The #1/4-20 kit is available in (4) finishes: Catalog No: SN1 Catalog No: SN1 Catalog No: SN1 Catalog No: SN1 p/n: X Brushed Brass BHMA 606 Finish Oil Rubbed Bronze BHMA 613 Finish Brushed Chrome BHMA 626 Finish Stainless Steel BHMA 630 Finish Narrow Stile Door Kit (Splice Kit may be used with either 3-0 or 4-0 units) Catalog No: NSK1 p/n: (628 Finish, Clear) p/n: (711 Finish, Black) Security Screws R Security Pin TORX Bits provided Key Stop Kit (Momentary Shunt) Catalog No: KS p/n: Key Stop Screw Dogging Lever Assembly (shown for reference ONLY) Double Door Strike Kit Catalog No: 94 Security screws p/n: Catalog No: 95 - Standard screws p/n: The following Models in the series were evaluated by UL: Controlled Exit Panic Devices; Model V40. These devices may be suffixed with 01, 02, 03, 08, 09, or 14 followed by A, AN, BN, CN, DN, DNT, DNU, MN, P, PN, or WS followed by BP2 or BP8 followed by 605, 606, 611, 612, 613, 625, 626, 628, 629, 630, or 711 followed by the RHR or LHR, followed by EBxW or EXxW, which may be followed by LD or CD, followed by 628 or 711, followed by 98 or 99, followed by 36 or Page 17

Endcap P/N: Pushpad Wrap P/N: X (3-0) P/N: X (4-0)

Endcap P/N: Pushpad Wrap P/N: X (3-0) P/N: X (4-0) 101275 November 12, 2010 Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com INSTALLATION

More information

LIFE SAFETY, SECURITY DOOR HARDWARE AND INTEGRATED DOOR SECURITY SYSTEMS PRICE LIST

LIFE SAFETY, SECURITY DOOR HARDWARE AND INTEGRATED DOOR SECURITY SYSTEMS PRICE LIST LIFE SAFETY, SECURITY DOOR HARDWARE AND INTEGRATED DOOR SECURITY SYSTEMS PRICE LIST Effective August 15, 2007 NOTES TABLE OF CONTENTS Order Conditions... Pg 1 Warranties... Pg 2 Standards and Certifications...

More information

02AN = Dummy pull; narrow trim. key removed; narrow trim (handed) 01PN = Exit only, blank plate; narrow trim. 02BN = Dummy lever; narrow trim

02AN = Dummy pull; narrow trim. key removed; narrow trim (handed) 01PN = Exit only, blank plate; narrow trim. 02BN = Dummy lever; narrow trim NOTE: * = default/standard All fire-rated devices Less Dogging/fail safe Also see online version at detex.com/hto September 6, 2018 Fire-rated trims must be Fail Safe (FSA) OUTSIDE TRIM FUNCTION & FINISH

More information

Electrical Options Booklet. Table of Contents

Electrical Options Booklet. Table of Contents *24228413* 24228413 Electrical Options Booklet Table of Contents EL Wiring... EL Troubleshooting... SD/EL 98/99 Cylinder Dogging... SS Wiring... 330, 350, RX-330 and RX-350 Push Bar Trim Mechanical Installation...

More information

Spectra Class. N6000 Series Exit Devices SECURITY DOOR CONTROLS. N6100 Rim Mount Exit Device. N6200 Surface Vertical Rod Exit Device.

Spectra Class. N6000 Series Exit Devices SECURITY DOOR CONTROLS. N6100 Rim Mount Exit Device. N6200 Surface Vertical Rod Exit Device. N6000 Series Exit Devices Spectra Class Rim Mount Surface Vertical Rod N6100 Rim Mount Exit Device For use on single doors or pair of doors with mullion 1-3/4"(44 mm) door thickness standard. Specify thickness

More information

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS These instructions

More information

9700/F9700 SERIES RIM EXIT DEVICE

9700/F9700 SERIES RIM EXIT DEVICE INSTALLATION INSTRUCTIONS 9700/F9700 SERIES RIM EXIT DEVICE Index: Screw chart Tools required Outside trim options "03" Additional door prep Device installation Options available 5300 retro-fit preparation

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 00 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) Track Assembly (0-) / Replacement

More information

Spectra Class - Specification Grade Exit Devices for superior Architectural Style & Performance

Spectra Class - Specification Grade Exit Devices for superior Architectural Style & Performance S6000 & N6000 Spectra Exit Devices Spectra Class - Specification Grade Exit Devices for superior Architectural Style & Performance The new mechanical SDC S6000 & N6000 Spectra series panic and fire rated

More information

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20 Exit Devices Section TABLE OF CONTENTS EXIT DEVICES PUSH BAR EXIT DEVICES N1500 Heavy Duty Rim Exit Device N1550 Rim Exit Device... 6 N1650 Fire Rated Heavy Duty Exit Device N1700(F) Vertical Rod Heavy

More information

KAWNEER 1686 CONCEALED EXIT DEVICE

KAWNEER 1686 CONCEALED EXIT DEVICE FEBRUARY, 2015 1 ROD AND CENTER CASE ASSEMBLY: 1) For inactive doors or doors without exterior cylinder, or doors without the need for exterior cylinder dogging, the removal of the cylinder dogging pawl

More information

Dor-O-Matic Exit Devices

Dor-O-Matic Exit Devices Dor-O-Matic Exit Devices T H E F A L C O N D I F F E R E N C E S A F E T Y, S E C U R I T Y A N D U N C O M P R O M I S I N G V A L U E At Falcon, we know that every product you sell not only has to meet

More information

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION *921297-00* 921297-00 Electric Locking Trim E996L Series Installation Instructions CAUTION Product is shipped in Fail Safe (FS) configuration. Fail Safe configuration is required by code in some applications

More information

An ASSA ABLOY Group brand Series. Flatbar Exit Devices

An ASSA ABLOY Group brand Series. Flatbar Exit Devices An ASSA ABLOY Group brand 1800 Series Flatbar Exit Devices introduction Yale 1800 series exit devices are the ideal choice for economy commercial applications where consistent quality, ease of use and

More information

8500 Narrow Design Rim Exit Device 80 Series

8500 Narrow Design Rim Exit Device 80 Series 8500 Narrow Design Rim Exit Device 8500 Series Narrow Design Rim Exit Device Specifications for 8500 Series Exit Door Types Rail sizes as determined by door width Strike Dogging Feature Electric Mounting

More information

33A/35A Series Exit Devices

33A/35A Series Exit Devices 33A/35A Series Exit Devices Introduction The proper selection and application of exit hardware, in addition to safety, are major concerns to all responsible manufacturers. Exit devices are a critical part

More information

KAWNEER 1686 EL CONCEALED EXIT DEVICE

KAWNEER 1686 EL CONCEALED EXIT DEVICE FEBRUARY, 2012 1 ROD AND CENTER CASE ASSEMBLY: 1) For inactive doors or doors without exterior cylinder, or doors without the need for exterior cylinder dogging, the removal of the cylinder dogging pawl

More information

RELIANT 5000 SERIES: EXIT DEVICES. Reliant 5000 Series. Exit Devices. Strength by design. Simply PRECISION

RELIANT 5000 SERIES: EXIT DEVICES. Reliant 5000 Series. Exit Devices. Strength by design. Simply PRECISION RELIANT 5000 SERIES: EXIT DEVICES Reliant 5000 Series Exit Devices Strength by design. Simply PRECISION TABLE OF CONTENTS Exit Devices & Trims Rim Devices...4, 5 Surface Vertical Rod Devices...6, 7 Mullions

More information

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions *44487296* M400 Series 44487296 Single Electromagnetic Locks: M420, M450, M490 Installation Instructions M420/M450 Armature plate assembly M490 Armature plate assembly Features Automatic Voltage Selection

More information

KEANE MONROE a member of the record group

KEANE MONROE a member of the record group SERIES 3000 / 3100 MICROPROCESSOR CONTROL REGULAR ARM SLIDE ARM / SLIDE ARM W/PANIC BREAKAWAY SERIES 3000 / 3100 Page 1. INDEX and OPERATOR HANDING The KM Series 3000/3100 operators have been carefully

More information

ED5470 Panic-Listed Surface Vertical Rod Exit Device ED5470B 1-1/2 Hour Fire-Listed Surface Vertical Rod Exit Device

ED5470 Panic-Listed Surface Vertical Rod Exit Device ED5470B 1-1/2 Hour Fire-Listed Surface Vertical Rod Exit Device Surface Vertical Rod Features ED5470 Panic-Listed Surface Vertical Rod Exit Device ED5470B 1-1/2 Hour Fire-Listed Surface Vertical Rod Exit Device Features Handing Device is handed but easily field reversible.

More information

PD10-M-RIM INSTALLATION INSTRUCTIONS. The PD10-M-RIM is a storefront grade 1 exit device equipped with motor drive latch retraction.

PD10-M-RIM INSTALLATION INSTRUCTIONS. The PD10-M-RIM is a storefront grade 1 exit device equipped with motor drive latch retraction. PD10-M-RIM INSTALLATION INSTRUCTIONS The PD10-M-RIM is a storefront grade 1 exit device equipped with motor drive latch retraction. Retrofits Doromatic 1790 & First Choice 3790. B. G. A. C. D. E. F. PD10-M-RIM

More information

98/99 Series Exit Devices

98/99 Series Exit Devices 98/99 Series Exit Devices 98/99 Finishes Finishes* Color US Number BHMA Number Chromium, Polished US26 625 Anodized, Aluminum US28 628 Chromium, Dull US26D 626 Brass, Polished US3 605 Brass, Dull US4 606

More information

33A/35A Series. Exit devices

33A/35A Series. Exit devices 33A/35A Series Exit devices Introduction The proper selection and application of exit hardware, in addition to safety, are major concerns to all responsible manufacturers. Exit devices are a critical part

More information

5600 Series Power Operator Installation and Instruction Manual

5600 Series Power Operator Installation and Instruction Manual 5600 Series Power Operator Installation and Instruction Manual 80-956-000-00 (08-) 5 ASSA ABLOY 6 Item No. Description Motor (5600M) Cover (5600COV) Control Inverter (5600IN) Power Supply VDC (5600PS)

More information

8800 Rim Exit Device 80 Series

8800 Rim Exit Device 80 Series 8800 Rim Exit Device 8800 Series Rim Exit Device 8800 Features Designed for standard width stile applications on wood and metal doors Also available as an HC8800 or WS8800 for hurricane-resistant applications,

More information

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY 0 Series Power Operator Installation and Instruction ASSA Manual ABLOY Item No. Description Motor (00M) Cover (00COV) Control Inverter (00IN) Power Supply VDC (00PS) / Replacement Motor Key (00KEY) Rod

More information

M670/M680BD MAGNALOCK SERIES Installation Instructions

M670/M680BD MAGNALOCK SERIES Installation Instructions Securitron www.securitron.com Tel 800.624.5625 techsupport@securitron.com M670/M680BD MAGNALOCK SERIES Installation Instructions Page 1 Rev. D, 12/14 Table of Contents Package Contents... 3 Mounting Hardware...

More information

33A/35ATM. Series. Exit Devices

33A/35ATM. Series. Exit Devices 33A/35ATM Series Exit Devices Introduction The proper selection and application of exit hardware, in addition to safety, are major concerns to all responsible manufacturers. Exit devices are a critical

More information

Concealed Vertical Rod Features

Concealed Vertical Rod Features Concealed Vertical Rod Features ED5800 Panic-Listed Concealed Vertical Rod Exit Device ED5800A 3-Hour Fire-Listed Concealed Vertical Rod Exit Device FOR USE WiTH METAL DOORS OnLy Features Handing Device

More information

ABS-AMERICAN BUILDING SUPPLY, INC. Von Duprin

ABS-AMERICAN BUILDING SUPPLY, INC. Von Duprin 22 - Rim Device 22 rim device for all types of single and double doors with mullion, UL listed for accident hazard installations. Covers stock hollow metal doors with 161 cutouts. Fits door stiles as narrow

More information

CONCEALED CLOSER SERIES

CONCEALED CLOSER SERIES CLOSER SERIES PRODUCT SELECTION GUIDE The concealed LCN closers feature a modern design for concealment in either the head frame or top rail of the door. This guide is based on the desired mounting of

More information

ADAMS RITE. ADAMS RITE MANUFACTURING COMPANY Sliding Hardware/Exit Devices Series Turns

ADAMS RITE. ADAMS RITE MANUFACTURING COMPANY Sliding Hardware/Exit Devices Series Turns Sliding Hardware/ 1000 Series Turns Series 1000 turns are designed to operate Adams Rite MS 1847 deadlocks and latches. 1000-11 and 1000-21 have a rectangular escutcheon for mounting directly on the door.

More information

Olympian 100, 200, 300 Series

Olympian 100, 200, 300 Series OLYMPIAN 100, 200, 300 SERIES : EXIT DEVICES Olympian 100, 200, 300 Series Exit Devices Strength by design. Simply PRECISION TABLE OF CONTENTS Exit Devices & Trims Rim Devices...4, 5 Surface Vertical Rod

More information

8800 Rim Exit Device 80 Series

8800 Rim Exit Device 80 Series 8800 Rim Exit Device 8800 Series Rim Exit Device 8800 Features Designed for standard width stile applications on wood and metal doors Also available as an HC8800 or WS8800 for hurricane-resistant applications,

More information

Entry. Entry. Entry. Entry

Entry. Entry. Entry. Entry Functions x 9800/9M800 AC2 Exit Device Outside Inside Series/Function Type Function Description ED5200(A) & ED5200S(A) *9833 Without Cylinder Outside lever locked (freewheeling) except when in passage

More information

Motorized Electric Latch Retraction

Motorized Electric Latch Retraction ; SECTION I: OVERVIEW 1. Description The Corbin Russwin MELR Electric Latch Retraction (ELR), refer to Figure 1, works with ED4000 & ED5000 Series exit devices to provide remote-controlled latch retraction

More information

lkm7001 key override module Installation Instructions Converting The LKM7000 to The LKM7003

lkm7001 key override module Installation Instructions Converting The LKM7000 to The LKM7003 lkm7001 Instructions Converting The LKM7000 to The LKM7003 key override module In A Single Motion, We ll Change The Way You Think About Security Read Instructions thoroughly prior to installation Base

More information

Package Contents. Mounting Hardware

Package Contents. Mounting Hardware Securitron Magnalock Corp. www.securitron.com Tel 800.624.5625 techsupport@securitron.com M680BDCX MAGNALOCK SERIES Installation Instructions Table of Contents Specifications 2 Configuring Options 3 Installation

More information

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market 1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Openings 85 to 0 or to 70 Double Lever Arm Application for Frame Reveals (76) to 7 (78mm)* Stop (Push) Side of Installation 5700 LEO Operator Installation Instructions

More information

PARTS MANUAL 98/99 SERIES RIM EXIT DEVICES. May RIM 98 RIM PM9899_G VD-GN Copyright 2013 Ingersoll Rand

PARTS MANUAL 98/99 SERIES RIM EXIT DEVICES. May RIM 98 RIM PM9899_G VD-GN Copyright 2013 Ingersoll Rand PARTS MANUAL May 0 9/99 SERIES RIM EXIT DEVICES 99 RIM 9 RIM PM999_G VD-GN-09 Copyright 0 Ingersoll Rand INDEX 9/99 Rim Devices Basic Panic Device... Basic Fire Device... Baseplate Assemblies... Center

More information

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E INSTALLATION INSTRUCTIONS CRL JACKSON 2085E ELECTRIC LATCH RETRACTION CONCEALED VERTICAL ROD PANIC EXIT DEVICE crlaurence.com Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com

More information

8888/8810 Multi-Function Rim Exit Device & Trim 80 Series

8888/8810 Multi-Function Rim Exit Device & Trim 80 Series 8888/8810 Multi- Rim Exit Device & Trim The 8888/8810 Rim Exit Device Devices are A156.3 UL Fire and Panic listed Device is non-handed /BHMA architectural finishes Four standard sizes available To Order:

More information

PARTS MANUAL 98/9927 SERIES EXIT DEVICES MAY 2013 PM989927_G VD-GN Copyright 2013 Ingersoll Rand

PARTS MANUAL 98/9927 SERIES EXIT DEVICES MAY 2013 PM989927_G VD-GN Copyright 2013 Ingersoll Rand PARTS MANUAL MAY 0 9/99 SERIES EIT DEVICES VD-GN- Copyright 0 Ingersoll Rand INDE 9/99 Devices Basic Panic Device... Basic Fire Device... Vertical Rods and Latches... Baseplate Assemblies... Center Case

More information

33A/35A Series. Exit devices

33A/35A Series. Exit devices 33A/35A Series Exit devices Introduction The proper selection and application of exit hardware, in addition to safety, are major concerns to all responsible manufacturers. Exit devices are a critical part

More information

98/99 Series Rim Exit Devices

98/99 Series Rim Exit Devices 98/99 Series Rim Exit Devices Service manual 99 RIM 98 RIM INDEX 98/99 Rim Devices Basic Panic Device... Basic Fire Device... Baseplate Assemblies... Center Case Assembly... Variations of the Basic Device

More information

DOUBLE LEVER ARM DOUBLE LEVER ARM SINGLE LEVER ARM 5010 SINGLE LEVER ARM

DOUBLE LEVER ARM DOUBLE LEVER ARM SINGLE LEVER ARM 5010 SINGLE LEVER ARM SERIES PRODUCT SELECTION GUIDE The concealed LCN closers feature a modern design for concealment in either the head frame or top rail of the door. This guide is based on the desired mounting of the closer.

More information

Table Of Contents. 30 Series Exit Device. On The Cover

Table Of Contents. 30 Series Exit Device. On The Cover 30 Series Exit Device Copyright 1999, 2001, 2004, 2008, 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table Of Contents Page Features, Applications and UL Fire

More information

EXIT DEVICES Reliant 5000 Series

EXIT DEVICES Reliant 5000 Series PRECISION HARDWARE EXIT DEVICES Reliant 5000 Series GENERAL INFORMATION TABLE OF CONTENTS EXIT DEVICES & TRIMS Page Rim Devices...4, 5 Surface Vertical Rod Devices...6, 7 MULLIONS Fire Labeled Removable

More information

ADDITIONAL INFORMATION

ADDITIONAL INFORMATION ADDITIONAL INFORMATION How to Order Sequence Example Prefixes CD AE DM KOR LK LM ED Rating F Blank Cylinder Dogging Touchbar Request to Exit Latchbolt and Device Monitor Switch Key Bypass Switch Locking

More information

* * Maintenance Kit

* * Maintenance Kit *941079-00* 941079-00 Maintenance Kit Page: TOC-1 Table of Contents Description: Page Number: Pictorial Index to Parts (immediatey follows Table of Contents )...PIP-1, PIP-2 1. Center Case Parts Insert-98/99

More information

22 Series. Exit device

22 Series. Exit device 22 Series Exit device Introduction Exit devices are a critical part of the Fire and Life Safety egress system and will provide safe and reliable service when properly applied and maintained. Von Duprin

More information

Recessed. Exit Device Series

Recessed. Exit Device Series Recessed Exit Device - 2390 Series Table of Contents 2390 Concealed Vertical Rod Device 3 Accessories 4 Power Supply 5 Door Application 6 How To Order 7 F A L C O N E X I T D E V I C E S Architectural

More information

98/99 Dogging options

98/99 Dogging options 98/99 Dogging options CDSI/HDSI dogging indicators Indicator provides an at-a-glance verification of the status of the door from inside of the room. Visible LOCKED and UNLOCKED indicators show whether

More information

Mustang CLASSIC LIGHT BAR INSTALLATION INSTRUCTIONS CDC #

Mustang CLASSIC LIGHT BAR INSTALLATION INSTRUCTIONS CDC # 1990-1993 Mustang CLASSIC LIGHT BAR INSTALLATION INSTRUCTIONS CDC # 101000 Kit Components: 1 Light Bar 4 Bolts ( 5 / 16-18 x 2.5 ) #182010 4 Washer #182005 4 Shims #182009 2 Dark Blue Connectors #182004

More information

Adams rite. Exit Devices & parts exit devices series exit device parts

Adams rite. Exit Devices & parts exit devices series exit device parts Adams rite Exit Devices & parts exit devices 8099 8211 8099 Active Dummy Bar with Switch Can be wired normally open or normally closed to operate maglock, alarm, etc No latching mechanism 8211 Surface

More information

Recessed. Touch bar exit devices

Recessed. Touch bar exit devices Recessed Touch bar exit devices Table of contents 3 2390 Concealed vertical rod device 4 Accessories 5 Power supply 6 Door application 7 How to order The Falcon difference Safety, security and uncompromising

More information

Table of Contents 20 Series Exit Device

Table of Contents 20 Series Exit Device 20 Series Exit Device Copyright 2003, 2007, 2009-2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Features, Applications and UL Fire Door Ratings...

More information

9827/9927 Surface mounted vertical rod device. 9827/9927 Surface mounted vertical rod device. Specifications Device functions

9827/9927 Surface mounted vertical rod device. 9827/9927 Surface mounted vertical rod device. Specifications Device functions Top latch 299 Top strike for all types of single or double doors, UL listed for panic exit hardware. Devices are ANSI A56.3 200 Grade. Covers stock hollow metal doors with 86 or 6 cutouts. The 9827 device

More information

20 Series. Exit Device

20 Series. Exit Device 20 Series Exit Device Copyright 2003, 2007, 2009, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Table of Contents Table Of Contents Page Features, Applications and UL

More information

*ININST.1002* 1690 Touchbar. Index:

*ININST.1002* 1690 Touchbar. Index: *ININST.1002* ININST.1002 Concealed Vertical Rod Panic Device 1690 Touchbar Installation Instructions Index: : The door prep for the 1690 Hex Bottom Rod is different than for the RL bottom rod. Please

More information

22 Series. Exit device

22 Series. Exit device 22 Series Exit device Introduction Exit devices are a critical part of the Fire and Life Safety egress system and will provide safe and reliable service when properly applied and maintained. Von Duprin

More information

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions SECTION I: OVERVIEW 1. Description The Sargent 56- prefix ELR works with 80 Series exit devices to provide remote-controlled latch retraction. It is compatible with the following prefixes: 53 - Latchbolt

More information

8800 Rim Exit Device 80 Series

8800 Rim Exit Device 80 Series 8800 Rim Exit Device 8800 Series Rim Exit Device 8800 Features Designed for standard width stile applications on wood and metal doors Also available as an HC8800 or WS8800 for hurricane-resistant applications,

More information

TS93 EMF T/PT/TDE. Surface applied door closer

TS93 EMF T/PT/TDE. Surface applied door closer TS9 EMF T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer (no smoke detector) (EMF T) Push side track mount closer (no smoke detector) (EMF PT) Double egress

More information

APEX 2000 SERIES: TOUCHBAR EXIT DEVICES. Apex 2000 Series. Touchbar Exit Devices. Strength by design. Simply PRECISION

APEX 2000 SERIES: TOUCHBAR EXIT DEVICES. Apex 2000 Series. Touchbar Exit Devices. Strength by design. Simply PRECISION APEX 2000 SERIES: TOUCHBAR EXIT DEVICES Apex 2000 Series Touchbar Exit Devices Strength by design. Simply PRECISION TABLE OF CONTENTS Wide Stile Exit Devices & Trims Rim Devices...4, 5 Surface Vertical

More information

OLYMPIAN 100, 200, 300 SERIES PRECISION HARDWARE

OLYMPIAN 100, 200, 300 SERIES PRECISION HARDWARE OLYMPIAN 100, 200, 300 SERIES PRECISION HARDWARE GENERAL INFORMATION TABLE OF CONTENTS EXIT DEVICES & TRIMS Page Rim Devices...4, 5 Surface Vertical Rod Devices...6, 7 Mortise Devices...8, 9 MULLIONS Fire

More information

5000 & F5000 Rim Type Panic And Fire Exit Devices 5000V & F5000V Vertical Rod Panic And Fire Exit Devices ANSI A156.3, Grade 2

5000 & F5000 Rim Type Panic And Fire Exit Devices 5000V & F5000V Vertical Rod Panic And Fire Exit Devices ANSI A156.3, Grade 2 5000 & F5000 Rim Type Panic And Fire Exit Devices 5000V & F5000V Vertical Rod Panic And Fire Exit Devices ANSI A156.3, Grade 2 Features & Construction ANSI A156.3, Grade 2 heavy duty exit device in surface

More information

*D-1015* D PARTS CHECK F-XX-V & XX-V EXIT DEVICES INSTALLATION INSTRUCTIONS. Customer Service

*D-1015* D PARTS CHECK F-XX-V & XX-V EXIT DEVICES INSTALLATION INSTRUCTIONS. Customer Service *D-1015* D-1015 2) TO CHANGE FROM STANDARD LOCKING TRIM TO EITHER NIGHTLATCH FUNCTION OR BLANK ESCUTCHEON, FOLLOW THE PROCEDURE BELOW: A) FOR NIGHTLATCH FUNCTION: 1) REMOVE AXLE SUPPORT ASSEMBLY (WITH

More information

Installation Instructions Z-Gate Shifter

Installation Instructions Z-Gate Shifter Installation Instructions Z-Gate Shifter Part Number 80681 1998, 2001 by B&M Racing and Performance Products The B&M Z-Gate shifter can be used in vehicles equipped with most popular three speed automatic

More information

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present TOMMY GATE OWNER'S / OPERATOR'S MANUAL 650 Series 650 LB Capacity 650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present Installing the Base Plate 1. Examine the interior and exterior

More information

33A/35A Series. Exit devices

33A/35A Series. Exit devices 33A/35A Series Exit devices Introduction Invest in longevity Von Duprin devices are engineered to add value over time. The robust materials and unique engineering add to the longevity, while the flexible

More information

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING CAUTION 80-957-00-00 (08-0) Series 570 Door Openings 85 to 0 or to 80 Adjustable Arm and Slide Track Application Maximum Hinge Side Frame Reveal to /8 (mm) Hinge (Pull) Side of Door Installation 5700 LEO

More information

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES PRODUCT SELECTION GUIDE SENTRONIC Series LCN closer/holders combine heavy duty closers with electrically controlled hold-open functions to control fire and smoke

More information

ARCHITECTURAL DOOR HARDWARE EXIT DEVICE CATALOG

ARCHITECTURAL DOOR HARDWARE EXIT DEVICE CATALOG ARCHITECTURAL DOOR HARDWARE EXIT DEVICE CATALOG January 1, 2017 v3 West Coast Office (800) 544-4422 East Coast Office (800) 225-6737 intldoorclosers.com Index EXIT DEVICES 5000 Series (Grade 2)...1-10

More information

ADDITIONAL INFORMATION

ADDITIONAL INFORMATION ADDITIONAL INFORMATION How to Order Sequence Example Prefixes CD AE DM KOR LK LM ED Rating F Blank Cylinder Dogging Touchbar Request to Exit Latchbolt and Device Monitor Switch Key Bypass Switch Locking

More information

98/99 Series. Exit devices

98/99 Series. Exit devices 98/99 Series Exit devices Introduction Exit devices are a critical part of the fire and life safety egress system and will provide safe and reliable service when properly applied and maintained. Von Duprin

More information

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2 FANs 268.1, 1628.3 Installation Bulletin M9000-150 Issue Date 0796 M9000-150 Damper Mount Linkage Kit Installation 21 18 19 20 2 22 17 2 4 3 2 15.5 393.7 1 17 16 15 11 13 12 8 9 10 2 5 Note: Damper mount

More information

Z-Gate Universal Shifter

Z-Gate Universal Shifter Installation Instructions Z-Gate Universal Shifter Fits: GM, Ford, Lincoln and Chrysler Transmissions See Application Guide for Specific Applications Part #80681 Rev 06/01/2018 WORK SAFELY! For maximum

More information

4000 Series Exit Devices Premier Product

4000 Series Exit Devices Premier Product 4 4000 Series Exit Devices Premier Product Certification & Compliance: u ANSI/BHMA A56., Grade ANSI A7. Accessibility Code Underwriters Laboratories (UL and CUL) listed for accident hazard (panic) standard.

More information

DETEX Low Energy Automatic Door Operator AO19-1 Single Door - Push

DETEX Low Energy Automatic Door Operator AO19-1 Single Door - Push 104850 January 31, 2013 Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)-629-2900 / 1-800-729-3839 / Fax (830)-620-6711 E-MAIL: detex @ detex.com INTERNET: www.detex.com DETEX

More information

22 Series Rim Exit Device. Service manual

22 Series Rim Exit Device. Service manual Series Rim Exit Device Service manual INDEX Rim Devices Basic Panic Device... 4-5 Basic Fire Device... 6-7 Baseplate Assemblies... 8 Center Case Assembly... 9 Variations of the Basic Device RX (Request

More information

Installation Instructions QUICKSILVER CONSOLE SHIFTER Fits: Chevelle / El Camino

Installation Instructions QUICKSILVER CONSOLE SHIFTER Fits: Chevelle / El Camino WORK SAFELY! For maximum safety, perform this installation on a clean, level surface and with the engine turned off. Place blocks or wedges in front of and behind both rear wheels to prevent movement in

More information

CAL-ROYAL & F2200 Rim Type Panic And Fire Exit Devices 2260 & F2260 Vertical Rod Panic And Fire Exit Devices ANSI A156.

CAL-ROYAL & F2200 Rim Type Panic And Fire Exit Devices 2260 & F2260 Vertical Rod Panic And Fire Exit Devices ANSI A156. CAL-ROYAL P R O D U C T S, I N C. 3 HOUR FIRE RATED 2200 & F2200 Rim Type Panic And Fire Exit Devices 2260 & F2260 Vertical Rod Panic And Fire Exit Devices ANSI A156.3, Grade 1 Lifetime Warranty BHMA CERTIFIED

More information

98/9947, 98/9949, & 98/9950 Series Exit Devices

98/9947, 98/9949, & 98/9950 Series Exit Devices 98/99 98/99, 98/999, & 98/990 Series Exit Devices 98/999 Service manual 98/990 INDE 98/99, 98/999, & 98/990WDC Devices Basic Device... - Panic and Fire Metal Door Concealed Vertical Rods and Latches...

More information

22 Series Exit Devices

22 Series Exit Devices 22 Series Exit Devices 22 Exit Device Finishes Color US Number BHMA Number Sprayed Aluminum SP28 689 Sprayed Dark Bronze SP313 695 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.

More information

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683 Installation Instructions QuickSilver Shifter Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683 WORK SAFELY! For maximum safety, perform this installation

More information

CV41. Vehicle Mounting Kit. Reference Guide

CV41. Vehicle Mounting Kit. Reference Guide CV41 Vehicle Mounting Kit Reference Guide CV41 Vehicle Mounting Kit Reference Guide........... 3 Secure the Smart Dock to a Vehicle.................... 3 Supply Power to the Smart Dock......................

More information

1 of 6. Installation Instructions. ED3200/ED3200A Series Rim Exit Device ASSA ABLOY. Plug FM362 (05/15) Inactive Case. Chassis. Inactive Case.

1 of 6. Installation Instructions. ED3200/ED3200A Series Rim Exit Device ASSA ABLOY. Plug FM362 (05/15) Inactive Case. Chassis. Inactive Case. Installation Instructions ED3200/ED3200A Series Rim Exit Device In U.S.: Corbin Russwin, Inc. 225 Episcopal Road Berlin, CT 06037 USA www.corbinrusswin.com In Canada: Door Security Solutions Canada 160

More information

STAINLESS STEEL CONTINUOUS HINGES TABLE OF CONTENTS. N No Hole (Blank) Hinges...2

STAINLESS STEEL CONTINUOUS HINGES TABLE OF CONTENTS. N No Hole (Blank) Hinges...2 TABLE OF CONTENTS C Concealed Electric Through-Wire...3 Custom Designs...2 Custom Hole Pattern...2 Custom Length Hinges...2 D Dutch Door Hinges...2 Dust Free Bearings...2 E Exposed Electric Switches...3

More information

CONCEALED CLOSER SERIES

CONCEALED CLOSER SERIES CONCEALED CLOSER SERIES APPLICATIONS n For aluminum, hollow metal, or wood doors and frames. n Can be used with hinge or pivot mounted door. n Closers for 4 or minimum 1-3/4 head frame or 4 top rail. n

More information

22 Series. Exit device

22 Series. Exit device 22 Series Exit device Introduction Built to protect Von Duprin products symbolize a commitment to safety and security. It s evident in the meticulous engineering behind every exit device. After all, keeping

More information

THE ENCLOSURE HARDWARE SUPPLIER

THE ENCLOSURE HARDWARE SUPPLIER FABTECH SUPPLY THE ENCLOSURE HARDWARE SUPPLIER Our Products JIC Style Enclosures JIC Style Cover Clamp Bracket... 5 JIC Style Cover Clamp... 6 JIC Style Cover Clamp Assembly... 6 JIC Cover Clamp Screws...

More information

EXIT DEVICES Apex 2000 Series

EXIT DEVICES Apex 2000 Series PRECISION HARDWARE EXIT DEVICES Apex 2000 Series GENERAL INFORMATION TABLE OF CONTENTS WIDE STILE EXIT DEVICES & TRIMS Page Rim Devices...4, 5 Surface Vertical Rod Devices...6, 7 Mortise Devices...8, 9

More information

Power Transfer Devices

Power Transfer Devices Security Door Controls 4 Power Transfer Devices From frame to door, SDC s power transfer devices provide secure, concealed or vandal-resistant means to transfer power and monitoring signals to doors equipped

More information

22 Series Exit Devices

22 Series Exit Devices 22 Series Exit Devices 22 Exit Device Finishes Color US Number BHMA Number Sprayed Aluminum SP28 689 Sprayed Dark Bronze SP313 695 2005 Ingersoll-Rand Co. May be copied for use with specification submittal.

More information

APOLLO Gate Operators, Inc.

APOLLO Gate Operators, Inc. APOLLO Gate Operators, Inc. Model 3500ETL/3600ETL Commercial Swing Gate Operator INSTALLATION MANUAL 01/08 CONTENTS IMPORTANT SAFETY INSTRUCTIONS. 3 Applications... 4 Pre-Installation Checklist... 5 Parts

More information

ROTON CONTINUOUS GEARED HINGES TABLE OF CONTENTS. L Length Specifications B Bearing at Top...4 Bearing on Top...4 Bearing Replacement Kit...

ROTON CONTINUOUS GEARED HINGES TABLE OF CONTENTS. L Length Specifications B Bearing at Top...4 Bearing on Top...4 Bearing Replacement Kit... TABLE OF CONTENTS B Bearing at Top...4 Bearing on Top...4 Bearing Replacement Kit... 10 C Center Punches... 10 Concealed Electric Monitoring... 5, 7 Concealed Electric Through-Wire... 5, 7 Concealed Electric

More information

98/99 Series. Exit devices

98/99 Series. Exit devices 98/99 Series Exit devices Introduction Exit devices are a critical part of the fire and life safety egress system and will provide safe and reliable service when properly applied and maintained. Von Duprin

More information