Technical Specifications. Conversion of the PU Foam Production Line. Al-Essa for Refrigeration and Air-conditioning Co. Ltd. Riyadh, Saudi Arabia

Size: px
Start display at page:

Download "Technical Specifications. Conversion of the PU Foam Production Line. Al-Essa for Refrigeration and Air-conditioning Co. Ltd. Riyadh, Saudi Arabia"

Transcription

1 APPENDIX Technical Specifications Conversion of the PU Foam Production Line Al-Essa for Refrigeration and Air-conditioning Co. Ltd. Riyadh, Saudi Arabia. Introduction Suppliers raw materials - Baalbaki, APC (Huntsman Arabian polyol co.), Bayer (Pearl insulation system house) Choice of technology to phase out HCFC The technology chosen is C-Pentane for the production of commercial Chest refrigerators and freezers. The choice of the type of pentane is not relevant for the production equipment. Products produced The company produces a range of chest refrigerators and freezers mainly for commercial purposes, models varying from 200 to 600 litres with foam weights up to 0 kg.

2 APPENDIX Existing machinery in use The company uses 2 Cannon HP machines from 985 one for door and one for cabinet foaming. The dry part consists of moveable fixtures driven by a chain system with about 5 fixtures in production. The fixtures have an aluminium core and before foaming pass through a pre-heating oven which is partially heated with heating elements. Typical cycle time is around one minute and foaming is performed at about kg/sec. The heating system needs to be reviewed as the electrical heating elements are not EX type and an external blower type heater is advisable.the heating system along with ceramic electrical heaters also have hot water radiators (curing oven temperature is maintained by these water heaters), electrical heaters are for providing direct heat to the cabinets and door moulds after chemical injection. Foaming is done with the cabinets in Bell position. After the curing the fixtures are opened by means of a manipulator. The fixtures itself do not have electrical equipment mounted on and therefore do not need to be modified. Cabinet fixture before foaming Foaming machine with mixing head mounted on boom 2

3 APPENDIX The doors are foamed on a separate production line on which the moulds are placed vertically and moved also moved through a preheating and curing oven. This oven is also equipped with heating elements and needs to be reviewed from safety point of view as the heaters are not EX. For foaming, the moulds are moved automatically in horizontal position and injection is accomplished through an injection hole with a closed mould. Foaming is done at about 500 grams/sec. Transport system for door moulds Door moulds manipulator for tilting the moulds in horizontal position For the doors and cabinets the existing booms for the mixing heads can be re-used but for using pentane a Nitrogen injection device will be required. 2. Equipment requested for conversion The foaming machines need to be replaced with machines suitable for the use of Pentane. Additionally a premixing unit is requested which would be used by both machines. 3

4 APPENDIX A safety system is required including ventilation, gas sensors and nitrogen injection before foaming into the cabinet and door fixtures. The beneficiary will take care of providing a room for placement of the premixing unit as well as storage of pentane drums. A room is already available for the storage of polyol and Isocyanate drums but it will need to be modified according to indications of the Contractor. 3. Technical specification Equipment specification for conversion of a commercial refrigeration cabinet and door line The offer must include: - 2 x High pressure foaming machine - x Safety system with gas sensors and ventilation - 2 x Nitrogen blanketing of fixtures and moulds - x Premix unit Polyol/Pentane - x ancillary equipment and services Therefore, the offer should include the following items: Nr. Description 2 Electrical cabinet - Pentane systems Safety cabinet and equipment 2 Worktank Isocyanate non flammable blowing agent 2 Worktank Polyol flammable blowing agent 2 Metering unit Isocyanate 2 Metering unit Polyol / Pentane Premix unit Polyol / Pentane 2 Mixing head suitable for PENTANE 2 Mixing head flexible hoses and mixing head support 2 Nitrogen injection Pentane storage tank equipment set Documentation set Safety whitebook Performance of metering units, machine output, premix unit, mixing head ) Performance for Cabinet foaming high pressure machine High pressure Metering unit Size of the pump (cc) Output of the pump (l/min) Contractor to enter data of size and output Polyol/ Pentane >= 28 cc >= 37 l/min..cc, l/min Isocyanate >= 28 cc >= 37 l/min..cc, l/min 2) Performance for Door foaming high pressure machine High pressure Size of the pump Output of the pump Contractor to enter 4

5 APPENDIX Metering unit (cc) (l/min) data of size and output Polyol/ Pentane >= 2 cc >= 6 l/min..cc, l/min Isocyanate >= 2 cc >= 6 l/min..cc, l/min Premixing unit Polyol with Pentane - Output > 20 l/min Mixing head ) Cabinet foaming mixing head - Size (internal diameter outlet pipe) >= 8 mm - Output with ratio : abt. kg/sec laminar flow 2) Door foaming mixing head - Size (internal diameter outlet pipe) >= 8 mm - Output with ratio : abt. 500 gram/sec laminar flow Electrical power supply of the beneficiary factory: V - 60 Hz - 3 phase + PE + earth - < +/- 0% power fluctuation The various items should comply with the below detailed specification Electrical cabinet - Pentane systems Cabinet Sufficiently sized for sealevel and ambient temperature 40 C with cooling Electrical parts set International Contractors Industrial computer International brand PLC with modules for EX parts Control panel >5 Inch touch-screen Mixing head electrical box for start, stop (Ex version) and foam program selection (the same panel of the main cabinet can be used when this is placed outside the Mixhead control panel machine room, otherwise a second panel has to be provided!) Electrical wires set According to EU standards Cable channels set Galvanised steel Signalisation Acoustical horn, status lamp (3 colours) 5 Contractor has to explain the foam program selection and placement of control panel or provide a price as option for a second panel.

6 APPENDIX EX parts Certification set Safety barriers for all electrical equipment polyol/pentane side ATEX, VDE, CE certification according to EU regulation For the complete plant: Safety cabinet and equipment Item Qty. Description Cabinet Sufficiently sized for sea level and ambient temperature 40 C with cooling Electrical parts set International Contractors Safety gas sensors foaming area 6 Gas sensors for cabinet and door foaming area Safety gas sensors foaming equipment 6 2 gas sensors for each foaming machine and 2 sensors for premix unit which also include storage area pentane drums Ventilation Double ventilator for foaming machine 2 and premix unit Ventilation Double ventilator for premix unit and Ventilation ducting Safety contacts Interface Remote alarm Grounding set 2 set storage area pentane drums Around foaming area, high pressure foaming machine and premix unit/pentane storage with sufficient flow throttle valves and evacuation points Potential free safety contact for power shutoff beneficiary power supply Power shutoff interface with foaming equipment, premix and dry part beneficiary Remote alarm station with acoustical horn and status lamp alarm with 50 m cables Grounding connections for supplied equipment and cabling for grounding beneficiary dry part Worktank Isocyanate non flammable blowing agent Worktank Volume minimal 250 l, min. 4 bar Cooling Double wall for water cooling with safety valve (when required) Level indicator Continuous level indicator with min and max alarm Supermax Separate supermax level sensor Pressurization Compressed air pressure regulator with safety valve and water sieve 6

7 APPENDIX Safety valve Safety valve CS or greycast with pressure release rigid piping Insulation Armaflex or mineral wool with Al covering Exit valve Manual exit valve Drainage Manual drainage valve Stirrer Stirrer and electrical drive motor External Plate heat exchanger welded type, with dt of >5 C Heat exchanger Temperature PT 00 Charging Piping Temperature control Membrane pump, capacity >30 l/min, with pneumatic ball valve, support structure, pressure regulator, pneumatic control valve and flexible connection to drum or tank storage Rigid steel piping from metering unit to work tank, flexible piping allowed from work tank to metering unit, piping for charging rigid on work tank flexible to membrane pump Temperature control unit feeding heat exchanger and double wall work tank with temperature controller, flex piping, valves, temperature sensor. Heating and cooling power to be indicated. Provide cooling power (KW) for the beneficiary chiller. Note: Chiller is not in the scope of supply! Worktank Polyol Flammable blowing agent Worktank Volume minimal 250 l, min. 0 bar Cooling double wall for water cooling with safety valve (when required) Level indicator EX - continuous level indicator with min and max alarm Supermax EX - separate supermax level sensor Pressurization compressed air pressure regulator with safety valve and water sieve Safety valve safety valve CS or greycast with pressure release rigid piping Insulation Armaflex or mineral wool with Al covering Exit valve EX - Pneumatic exit valve Drainage Manual drainage valve with Lock Stirrer Stirrer with Magnetic coupling and Heat exchanger Temperature EX - PT 00 Charging electrical drive motor External Plate heat exchanger welded type, with dt of >5 C Membrane pump, capacity >30 l/min, with EX-pneumatic ball valve, support structure, pressure regulator, EXpneumatic control valve and flexible 7 Provide RPM stirrer

8 APPENDIX Piping Temperature control connection to drum or tankstorage Rigid steel piping from metering unit to worktank, flexible piping allowed from worktank to metering unit, piping for charging rigid on worktank flexible to membrane pump Temperature control unit feeding heat exchanger and double wall worktank with temperature controller, flex piping, valves, temperature sensor. Heating and cooling power must be indicated Provide cooling power (KW) for the beneficiary chiller. Note: Chiller is not in the scope of supply! Metering unit Isocyanate Metering unit Swashplate Axial Piston metering pump withhandwheel Pump size See performance parameters introduction E-motor Single speed electrical motor, 500 rpm E-motor pump coupling Magnetic coupling suitable sized to avoid overheating Flowmeter Flowmeter with accuracy +/- % output Indicate accuracy, metering pump type and brand Filter Suction filter wire edge type with cleaning handle/knob Low pressure Digital low pressure gauge 0-50 bar with gauge display High pressure gauge Digital High pressure gauge bar with display Pump drainage Manual high pressure relief valve with piping High pressure valve High pressure ball valve Low pressure recirculation Hydraulic recirculation valve with EX solenoid or pneumatic actuated valve Production piping Connection with non-return valve on return line to worktank Piping Carbon Steel Spillage collection Metal or plastic removable collection basin underneath complete metering unit Metering unit Polyol / Pentane Swashplate Axial Piston metering pump Metering unit with handwheel Pump size See performance parameters introduction 8

9 APPENDIX E-motor Single speed electrical motor, 500 rpm E-motor pump coupling Magnetic coupling suitable sized to avoid overheating Flowmeter Flowmeter with accuracy +/- % output metering pump Filter Suction filter wire edge type with cleaning handle/knob Low pressure gauge Digital low pressure gauge 0-50 bar High pressure gauge Digital High pressure gauge bar Pump drainage Manual high pressure relief valve with piping High pressure valve High pressure ball valve Low pressure Hydraulic recirculation valve with EX recirculation solenoid or pneumatic actuated valve Production Connection with non-return valve on piping return line to worktank Piping Carbon Steel Spillage Metal or plastic removable collection collection basin underneath complete metering unit Indicate accuracy, type and brand For both foaming machines one common: Premix unit Polyol / Pentane Metering unit Double gear pump, pneumatic or other type of system, pump polyol and pump pentane total output >20 liter/min Mixture ratio 2 to 5% of pentane on polyol E-motor Depending on system chosen, EX type of motors, drives or valves Magnetic coupling suitable sized to avoid E-motor pump overheating for pentane, Polyol double coupling mechanical seal Filter Suction filter wire edge type for polyol with cleaning handle/knob Low pressure EX-Digital low pressure gauge 0-50 bar gauge 2 for polyol and pentane High pressure EX-Digital High pressure gauge 0-50 bar gauge Flow measurement 2 for mixture flowmeterpolyol, EXflowmeter Pentane Manual high pressure relief valve with piping Pump drainage High pressure valve High pressure ball valve Production connection with non-return valve to HP piping machine distance abt. 0 m Piping Carbon Steel Spillage Metal or plastic removable collection 9

10 APPENDIX collection Pentane drum charging Polyol charging tankstorage Pentane safety Pentane safety gas sensors 2 basis underneath complete metering unit Steel platform with spillage control for charging pentane from drum, inclusive of membrane pump sized according to premix unit and flow no-flow sensor Pneumatic valve, non-return valve and potential free contact for signalling start charging of beneficiary tank storage Autonomous ventilation system and encapsulation of the premix unit as well as pentane drum charging pentane sensors with interface with safety control board Mixing head suitable for PENTANE Mixing head L-Type mixing head Output max. See performance parameters introduction Size head Internal diameter outlet pipe suitable for flow speed <3 m/sec, laminar flow Position Vertical pouring for CABINET foaming and horizontal for DOOR foaming Sensors position sensors control and cleaning 2 piston EX Movement Manual with mounted on handle Control box Mounted on head Actuation Hydraulic with valves mounted on head or boom EX Other Outlet pipe with DIN thread for attachment of hose Nitrogen blanketing fixtures and moulds Injection device The nitrogen has to be injected before the foaming and can be performed directly through the mixing head or with a separate device. Control valves Solenoid or other valves for activating the nitrogen injection Pressure regulation and electronic Pressure pressure gauge for verification that regulation sufficient nitrogen is available. Flexible hose of abt. 0 m and holding Flexible hose bracket for injection device (rigid piping Set from the bottle storage to the injection 0

11 APPENDIX controls are provided by the beneficiary). Alarms Acoustical and visual alarm in case of malfunction or lack of Nitrogen. Control Software control and interface with foaming program Mixing head Boom cabinet and door line Mixhead bracket for vertical foaming of Mixhead support cabinets and horizontal foaming of doors Flexible hoses guide set Set of drawings for flexible hoses support and guide. The beneficiary will provide and install the system. The beneficiary has already booms and supports available Rigid Steel piping / mixhead electrical cables Abt Piping to fill the HP machine worktank to Premix unit to 50 be supplied and installed by beneficiary HP machine m according to specification of Contractor Supports and fixation Provided by beneficiary according to Contractor design Insulation PU or other type of insulation >20 mm Flexible hoses Mixhead electrical cables 50m App 20m set thickness Flexible hoses for hydraulics, Polyol/Pentane and Isocyanate to the mixing head to be provided by the CONTRACTOR. Set of electrical cables according to required length Contractor must include in the scope of supply Contractor must include in the scope of supply - Note the HP machine must be suitable dimensioned for the above indicated piping lengths - Note the beneficiary will provide a suitable room for placement of the machine - All the piping lengths are approximate Pentane Storage Tank Equipment

12 APPENDIX Double membrane pumps with pulsation Feed pumps damper or pump according to choice of Indicate clearly the Contractor with sufficient output for output and type of Set the production line pump proposed Pressure sensor Pressure manometer or guage Temperature sensor PT 00 in feed line Tank charging Set of ball valves pneumatically operated and grounding plier for loading by gravity Double wall Leakage control device for double wall of leakage control the tank Pressure Pressure relief valve on feed line to keeping valve Pressure keeping valve discount. block metering pump continuous line Pressure relief valve on feed line to metering pump discontinuous block foaming equipment Safety valve Safety valve Level control Continuous level control Tank blanketing Electrical control Safety valve, pressure regulator and ancillary equipment for tank blanketing with Nitrogen Electrical cabinet for control of the pumps, interface with production equipment, grounding and tank loading inclusive of acoustical horn and warning lamps Standards All equipment for ATEX Zone 0 Drawings Set Drawing for double wall pentane tank 5 to 20 T for the underground storage 4. Documentation Necessary documentation to be provided Nr. Description User manual Maintenance and repair manual Spare parts manual List of certifications, ATEX, CE, Pressure vessel, safety valves etc. of all components Electrical cabinet VDE, CE certification according to EU Electrical cabinet electrical diagram Whitebook with layout of the factory (dwg drawing will be provided by the beneficiary) and description of all the safety measures taken for the use of Pentane. This whitebook shall be according to TüV standards and can upon the decision of the beneficiary be submitted to the TüV. Full installation report with settings of the machinery, verification of all safety systems, commissioning record and final drawings, electrical schematic. Layout drawings for premix room and pentane storage area Layout drawings for High pressure foaming machine Drawings for mixing head guide and support system Drawings for the local manufacture of a 5 to 20 T pentane tank for the 2

13 APPENDIX underground storage - Language manual and all component manuals: ENGLISH - All manuals in hard and electronic copy 5. Local Works (provided by the Beneficiary) The beneficiary will provide the following: - Room with air conditioning for storage of raw materials - Room for Pentane drums and premix unit according to drawings of Contractor - Electrical power supply to the E-cabinets of the Contractor equipment - Compressed air 6 bar minimum and piping to the HP machine - Nitrogen for blanketing of Polyol/pentane worktank and piping to the HP machine (bottles) - Chilled water for cooling HP machine - Ventilation ducting to the roof of the factory from the ventilators upwards - Grounding of the press and provision of grounding points according to Contractor indication - Water heating of the presses - Power shut-off switch activated by potential free contact of Contractor safety system - Antistatic floor when required - Polyol/Pentane piping from the premix unit to the HP machine worktank - All required legal allowances - Sufficient raw materials for testing - Civil works (works related to the installation of the foaming machines) 6. Training Training on site at the Project Counterpart The Contractor shall provide 3 days training. All costs for flight, board and room shall be borne by the Contractor. Local transport will be provided by the beneficiary as well as lunch. The training shall be started after the commissioning has been finished and acceptance signed. 7. Implementation/Installation/Personnel Contractor scope Bidders shall specify in their proposals the implementation schedule as well as the number, details, and CVs of key personnel. The beneficiary will provide Electrical-, Mechanical engineer as well as sufficient workers. Specific lifting equipment and tools required for the installation should be timely notified by the Contractor to the beneficiary. All costs for flight, board and room shall be borne by the Contractor. Local transport will be provided by the beneficiary as well as lunch. 3

14 APPENDIX Responsibilities of the Beneficiary Based on the final detailed technical information provided by the Contractor, the beneficiary will prepare all required local works. One month before shipment of the equipment the Contractor has the right to visit the installation site and verify the status of work. In case of severe deviations by either party, the parties agree to inform each other so that eventual delays can be discussed on a timely basis. Safety verification The verification of the proper installation performed by the Contractor in full compliance with the Whitebook shall be performed jointly by the Contractor and the beneficiary and shall be properly documented. 8. After Sales Service During the first year of operation a minimum of two visits of service engineers should be envisaged by the Contractor for trouble shooting and general after sales service. One engineer visit after one calendar quarter and one visit at the end of the warranty period. If some problems concerning equipment and technology occur during the process of production and the beneficiary cannot resolve them, also through assistance with other means of communication, the Contractor shall send proper qualified personnel to the beneficiary site assisting to resolve the problems. The expenses in connection with such work shall be borne by the Contractor in case these problems are attributed to the equipment or technology during the warranty period. In case the problems are due to wrong handling of the equipment the beneficiary shall bear the costs of the not programmed after sales service visits. 9. Warranty period 2 months from the date of final acceptance but not longer than 24 months after shipment 0. Packaging and transport conditions Packaging for sea transport DAP Riyadh Kingdom of Saudi Arabia shall be performed by the Contractor, by duly considering the type and nature of the equipment.. Timeline The delivery of equipment has to be accomplished no later than six (6) months of contract signature. The installation and commission shall be accomplished not later than two (2) months after the delivery of equipment at work site. 4

Technical Specification. Insulated Roofs and Walls Ind. Co. Ltd (HESCO) Jeddah

Technical Specification. Insulated Roofs and Walls Ind. Co. Ltd (HESCO) Jeddah Technical Specification Insulated Roofs and Walls Ind. Co. Ltd (HESCO) Jeddah. Content Introduction... Company data... 2 Consumption data PU Foam... 2 Suppliers raw materials... 3 Choice of technology

More information

PROCUREMENT PLAN FOR ARICO SUB-PROJECT PROPOSAL. Estimate Cost (USD) Procurement Method. As specified in the PIM of the HCFC phase out Project

PROCUREMENT PLAN FOR ARICO SUB-PROJECT PROPOSAL. Estimate Cost (USD) Procurement Method. As specified in the PIM of the HCFC phase out Project re Authorized Code A. Imported 1 1 PROCUREMENT PLAN FOR ARICO SUB-PROJECT PROPOSAL Cyclo-pentane storage system 01 set 500 lt Cyclo-pentane storage tank & pneumatic C5 loading pumps Piping and accessories

More information

A- Compact. High Pressure Metering Machines for Polyurethanes. Automotive Interiors & Exteriors. Refrigerator Insulation.

A- Compact. High Pressure Metering Machines for Polyurethanes. Automotive Interiors & Exteriors. Refrigerator Insulation. A- Compact High Pressure Metering Machines for Polyurethanes Automotive Interiors & Exteriors Refrigerator Insulation Panel Insulation Rigid, Flexible & Integral Foams for Furniture Building & Piping Insulation

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

PURe Mix Technology for Mixing and Metering

PURe Mix Technology for Mixing and Metering PURe Mix Technology for Mixing and Metering For a PURe variety of applications FRIMO PURe Mix Technology for Mixing and Metering Having more than 40 years of experience in production technology for the

More information

Product Overview. 1.0 About VRB-ESS. 2.0 System Description. MW-Class VRB-ESS

Product Overview. 1.0 About VRB-ESS. 2.0 System Description. MW-Class VRB-ESS 1.0 About VRB-ESS Pu Neng s VRB-ESS is an electrical energy storage system based on the patented vanadium redox battery (VRB ) that converts chemical to electrical energy. Energy is stored chemically in

More information

SEATING TECHNOLOGY POLYURETHANE TECHNOLOGY DIVISION

SEATING TECHNOLOGY POLYURETHANE TECHNOLOGY DIVISION POLYURETHANE TECHNOLOGY DIVISION SEAT PRODUCTION Seat production for the automotive and furniture markets is one of the largest and best known consumers of Polyurethane world-wide. Today's manufacturers

More information

Technical Specification. for. Supply, installation and commissioning of Diesel Generators for UNDP

Technical Specification. for. Supply, installation and commissioning of Diesel Generators for UNDP United Nations Development Programme Recovery and Crisis Prevention برنامج األمم المتحدة اإلنمائي Iraq Technical Specification for Supply, installation and commissioning of Diesel Generators for UNDP February

More information

VERSAFLOW MAG 4000 Quick Start

VERSAFLOW MAG 4000 Quick Start VERSAFLOW MAG 4000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. CONTENTS VERSAFLOW MAG 4000

More information

Double Column Machining Center VM3018A With FANUC 0i MF LINEAR GUIDE WAY ON ALL THREE AXIS

Double Column Machining Center VM3018A With FANUC 0i MF LINEAR GUIDE WAY ON ALL THREE AXIS Offer date:2017/2/8 Quotation No.VM3018AFMF20170208A Double Column Machining Center VM3018A With FANUC 0i MF LINEAR GUIDE WAY ON ALL THREE AXIS Stock Machine for Index: A.) General Machine Description

More information

Ciject One. CIJECT One- RTM/VRTM Injection Machine

Ciject One. CIJECT One- RTM/VRTM Injection Machine Ciject One CIJECT One- RTM/VRTM Injection Machine A sophisticated machine with programmable functions and an extensive level of control options. The Ciject One features an unrivalled level of control with

More information

Starting up hydraulic systems

Starting up hydraulic systems General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable

More information

. Rohrweg 31 D Höxter Germany Page: 1 of 6 P.O. Box D Höxter Germany Date: 13/01/ :15

. Rohrweg 31 D Höxter Germany Page: 1 of 6 P.O. Box D Höxter Germany Date: 13/01/ :15 info@gronemeyer.org www.gronemeyer.org Rohrweg 31 D-37671 Höxter Germany Page: 1 of 6 P.O. Box 10 02 53 D-37652 Höxter Germany Date: 13/01/2012 14:15 To: Unilever Our sign: Mr Pötzke Attn. of: Francesco

More information

Example application for an supply air control with recirculated air addition. HVAC Application Note 3

Example application for an supply air control with recirculated air addition. HVAC Application Note 3 Example application for an supply air control with recirculated air addition HVAC Application Note 3 Version 14.03.2007 2 General Copyright 2007 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved.

More information

M-22 DUAL FUEL ENGINE

M-22 DUAL FUEL ENGINE Guideline No.: M-22(201510) M-22 DUAL FUEL ENGINE Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

Special Projects. Pump Modules. Fluid complete solutions from the KRAL brand. s i n c e PUMPS.

Special Projects. Pump Modules. Fluid complete solutions from the KRAL brand. s i n c e PUMPS. Pump Modules. Fluid complete solutions from the KRAL brand. PREMIUM MANUFACTURER s i n c e 1 9 5 0 PUMPS www.kral.at Expertise and Experience. KRAL AG is a leading company in the field of pump and flow

More information

M-11 MARINE DIESEL ENGINE FUEL INJECTOR

M-11 MARINE DIESEL ENGINE FUEL INJECTOR Guideline No.M-11(201510) M-11 MARINE DIESEL ENGINE FUEL INJECTOR Issued date: 20 October 2015 China Classification Society Foreword This Guideline constitutes the CCS rules, and establishes the applicable

More information

Axial Piston Variable Pump A2VK

Axial Piston Variable Pump A2VK Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Axial Piston Variable Pump A2VK RE 94001/06.10 1/12 Replaces: 07.04 Data sheet Size 12 to 107 Series 1

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

ProMinent. 1.1 ProMinent: Innovations In Chemical Feed Technology ProMinent Dosing Dosierstation Station: Comprehensive

ProMinent. 1.1 ProMinent: Innovations In Chemical Feed Technology ProMinent Dosing Dosierstation Station: Comprehensive 1.1 rominent: Innovations In Chemical Feed Technology 1.1. rominent Dosing Dosierstation Station: Comprehensive Verfahrenssicher ccessory ange durch Ensures komplettes rocessing Zubehör Safety Note: Excessive

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

Angle seat valve with piston actuator VZXA-...-K

Angle seat valve with piston actuator VZXA-...-K Angle seat valve with piston actuator VZXA-...-K Festo AG & Co. KG Postfach 73726 Esslingen Germany +49 711 347-0 www.festo.com 3 Further information Accessories www.festo.com/catalogue Spare parts www.festo.com/spareparts

More information

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1. Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.3, 5/16/18 1.0 Scope This document is currently limited in scope to inverter interfaced PV installations

More information

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X Variable Vane Pump, Direct Controlled PV7...A Series 1X / X RE 1 Issue: 1.13 Replaces: 8.8 Sizes 1 to Maximum pressure 1 bar Displacement volume 1 to cm 3 Features Very short control times Low noise Mounting

More information

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200

More information

1x New Siemens SGT MW 50 / 60Hz (DF) Gas Turbine Mobile Generator Set

1x New Siemens SGT MW 50 / 60Hz (DF) Gas Turbine Mobile Generator Set 1x New Siemens SGT400 12.9 MW 50 / 60Hz (DF) Gas Turbine Mobile Generator Set 1. Scope of Supply Siemens Industrial Turbomachinery Ltd hereinafter Siemens offer to design,manufacture, package and despatch

More information

A. General Specifications. B. Dimensional Layout. BTU International Specification: Model 150Nz12 Reflow Solder System Date: 11/05/09 Page: 1/6

A. General Specifications. B. Dimensional Layout. BTU International Specification: Model 150Nz12 Reflow Solder System Date: 11/05/09 Page: 1/6 Page: 1/6 A. General Specifications Maximum temperature rating (all zones): 350 C Nominal operating temperature: 80-350 C Number of controlled heated zones: 12 Top 12 Bottom Oven atmosphere: Air/N 2 Working

More information

Electric expansion valves Types AKVA 10, 15 & 20

Electric expansion valves Types AKVA 10, 15 & 20 Data sheet Electric expansion valves Types AKVA 10, 15 & 20 AKVA are electric expansion valves designed for ammonia refrigerating plant. The AKVA valves are normally controlled by a controller from Danfoss

More information

Blue e+ chillers with the principle

Blue e+ chillers with the principle Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide

More information

Pneumatic Axial Fan Type Tech. Doc. No. 802

Pneumatic Axial Fan Type Tech. Doc. No. 802 Pneumatic Axial Fan Type Tech. Doc. No. 802 Illustration can differ from the original Operation and Maintenance Manual Compiled: 06.08.13 815340300_en_Version_02 Page 1 of 11 ATTENTION!!! This pneumatic

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Technical specification. Recycler WR 2400

Technical specification. Recycler WR 2400 Technical specification Recycler WR 2400 Technical specification Working width (max.) Working depth * 1 Milling and mixing rotor Tool spacing Recycler WR 2400 2,400 mm 0 500 mm 20 mm Number of tools 186

More information

OPTIFLUX 2000 Quick Start

OPTIFLUX 2000 Quick Start OPTIFLUX 2000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS OPTIFLUX 2000

More information

MIXING CENTRE FOR DELIVERY OF CELLULAR CONCRETE

MIXING CENTRE FOR DELIVERY OF CELLULAR CONCRETE MIXING CENTRE FOR DELIVERY OF CELLULAR CONCRETE Type: MS 1000M Data Sheet No. 011.1 A machine for making and delivery of lightweight concrete (LC) filled with technical foam foam concrete (PBG) or with

More information

TRASH RACK CLEANING MACHINE

TRASH RACK CLEANING MACHINE TRASH RACK CLEANING MACHINE 1 SCOPE The work includes the design, manufacturing, supply, transportation, handling, storage, installation (including 1 st and 2 nd Stage embedded parts and any other necessary

More information

Electrical Control Valves

Electrical Control Valves 172 Electrical Control Valves Electrical Control Valves Electrical Control Valve Technology Thermostatic expansion valves and mechanical regulator valves have been used in the refrigeration and air conditioning

More information

Implementation procedure for certification and continued airworthiness of Beriev Be-200E and Be-200ES-E

Implementation procedure for certification and continued airworthiness of Beriev Be-200E and Be-200ES-E 1. Scope 1.1 The general process is described in the implementation procedure for design approvals of aircraft, engine and propeller from CIS and in the implementation procedure for design approvals of

More information

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev MORATTO S.R.L. Electrical Machinery I 31030 PERO DI BREDA (Treviso) Italy Via A Volta, 2 Tel. +390422904032 fax +39042290363 www. moratto.it - moratto@moratto.it THREE PHASE AND SINGLE PHASE ASYNCHRONOUS

More information

Combustion process Emission cleaning Fuel distribution Glow plugs Injectors Low and high pressure pumps

Combustion process Emission cleaning Fuel distribution Glow plugs Injectors Low and high pressure pumps Page 1 of 16 S60 (-09), 2004, D5244T, M56, L.H.D, YV1RS799242356771, 356771 22/1/2014 PRINT Combustion process Emission cleaning Fuel distribution Glow plugs Injectors Low and high pressure pumps Fuel

More information

Guideline No.M-10(201510) M-10 Marine Diesel Engine Fuel Injection Pump

Guideline No.M-10(201510) M-10 Marine Diesel Engine Fuel Injection Pump Guideline No.M-10(201510) M-10 Marine Diesel Engine Fuel Injection Pump Issued date: 20 th October, 2015 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains technical

More information

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation. FORM WCCL-PC3 WCCL TEST STAND APPROVAL PROCEDURE AND CHECKLIST AHRI CERTIFICATION PROGRAM FOR WATER-COOLED WATER CHILLING AND HEAT PUMP WATER-HEATING (WCCL) PACKAGES WCCL Participant: Date of Inspection:

More information

ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL

ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL ELECTRIC LIFTER TROLLEY INSTRUCTION MANUAL Imported exclusively by Pacific Hoists Pty. Ltd. & Pacific Hoists Ltd. In support of cancer charities in Australia & New Zealand 2 www.jbstools.com WWW.CHALLENGERHOISTS.COM.AU

More information

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off

More information

Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50

Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50 Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50 AK-Ex with electric actuator II 2G c II TX II 2D c II T 80 C AK-Ex with pneumatic actuator II 2G c IIB TX

More information

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters System 6000 Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters Edition April 2018 Information Sheet T 6000 EN Electropneumatic Converters i/p converters

More information

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8 Electrical Control s Series EX4, EX5, EX6, EX7 & EX8 Features Multifunction as expansion valve, hot gas bypass, suction gas throttling, head pressure, liquid level actuator etc. Fully hermetic design (no

More information

Lloyd s Register Type Approval System Test Specification Number GT04

Lloyd s Register Type Approval System Test Specification Number GT04 Lloyd s Register Type Approval System Test Specification Number GT04 Gas Turbines Performance and test specifications for Gas Turbines to be used in Marine, Offshore and Industrial Applications 2004 Lloyd's

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat 00 / way poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V 9 Valves for safety systems up to SIL Solenoid valve

More information

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet. SHEET 1 OF 5 1.0 GENERAL & SCOPE 1.1 This specification covers the design, material, construction features, manufacture, inspection & testing, Painting and packing requirements of Spring Loaded Bypass

More information

Safety drying ovens with expanded temperature range

Safety drying ovens with expanded temperature range MDL series 115 Safety drying ovens Safety drying ovens with expanded temperature range The BINDER MDL, with enhanced control function, works at temperatures up to 350 C (662 F). It is it perfectly suited

More information

VALIADIS S.A. Hellenic Motors Quality Assurance Certificate EN ISO 9001:2008 C e r t i f i c a t e R e g. N o

VALIADIS S.A. Hellenic Motors Quality Assurance Certificate EN ISO 9001:2008 C e r t i f i c a t e R e g. N o XRZ Series Thin Oil Lubricator 1.Usage : The product mainly applies to mechanical thin oil circle lubrication system of cement metallurgy, rolling, mine energy sources, light industry, transportation petrochemistry

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

Safety drying oven with expended temperature range

Safety drying oven with expended temperature range MDL series 115 Safety drying ovens Safety drying oven with expended temperature range The BINDER MDL 115 with enhanced control function works at temperatures up to 350 C. This safety drying oven meets

More information

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc 13.10.2017-1 - CTS - Climatic Test Cabinet Type CP+10/1200 C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English

More information

5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD) Water Injection

5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD) Water Injection Bargh afshan alborz Amol Mazandaran Iran Tel: +98 (0)1212229599 Fax: +98 (0)1213239001 Email: ba_alborz@yahoo.com www.alborzgenerator.com 5 x Solar Turbomach Taurus T60 (5.67MW ISO) Dual Fuel (Gas & HSD)

More information

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...

More information

a measurable difference...

a measurable difference... This testing machine with integrated steel plate welded frame structure, using single boom and double-function piston liner to load testing force and fixing specimen with cylindrical pin, load cell measuring

More information

Providing a constant temperature control and high cooling efficiency.

Providing a constant temperature control and high cooling efficiency. Recirculating Coolers (General) Providing a constant temperature control and high cooling efficiency. Performance Temperature range from 3 to 40. High cooling capacity up to 7.1kW at 20. Powerful circulating

More information

Pumps and Flow Measurement for the Polyurethanes Industry

Pumps and Flow Measurement for the Polyurethanes Industry Pumps and Flow Measurement for the Polyurethanes Industry 2 Pumps and flow measurement for the polyurethanes industry Content 3 Company 5 Gear Pumps for the Polyurethanes Industry 6 Pressure Relief Valves

More information

Technical specification for NDC 40 NO Rescue Boat Davit

Technical specification for NDC 40 NO Rescue Boat Davit Technical specification for NDC 40 NO Rescue Boat Davit 8.06.203 Re issued for construction PGO GNI GNI 0 25.04.203 Issued for construction PGO GNI GNI REV.: DATE: Reason for Issue / Description: Project

More information

Profile Spraying Machine, Makor Model IRIDE 206/W (Modified)

Profile Spraying Machine, Makor Model IRIDE 206/W (Modified) TECH SPEC PAGE 1 Profile Spraying Machine, Makor Model IRIDE 206/W (Modified) The spraying machine IRIDE 206 has been designed for the protection of the work environment, and built to satisfy present-day

More information

Hydraulic primary unit Type ABPAG

Hydraulic primary unit Type ABPAG RE 51 018/11.02 Replaces: 07.96 Hydraulic primary unit Type PG Reservoir volumes 63 to 400 litres Maximum operating pressure 360 bar H 2375 Type PG.. Overview of contents Contents Page Features 1, 2 Ordering

More information

Operating Manual for the RE-19 Multi-pin Valve Terminal

Operating Manual for the RE-19 Multi-pin Valve Terminal Operating Manual for the RE-19 Multi-pin Valve Terminal Version: RE 19M/05/99 Order no. 54-RE-19-M-GB Contents Introduction...3 RE-19 valve terminal with multi-pin connection...4 Components of the RE-19

More information

TECHNICAL SPECIFICATIONS FOR BATTERY OPERATED HEAVY DUTY FORK LIFT TRUCK - 20 T

TECHNICAL SPECIFICATIONS FOR BATTERY OPERATED HEAVY DUTY FORK LIFT TRUCK - 20 T PART B TECHNICAL SPECIFICATIONS FOR BATTERY OPERATED HEAVY DUTY FORK LIFT TRUCK - 20 T 1.0 APPLICATION / PURPOSE : S.No. DESCRIPTION / SPECIFICATIONS 1.1 The proposed Fork Lift Truck is meant to be employed

More information

SERVOMEX 335A2014 PURGE ASSY Operator Manual

SERVOMEX 335A2014 PURGE ASSY Operator Manual SERVOMEX 335A2014 PURGE ASSY Operator Manual Part Number: 335A2014-MAN Revision: 1 Language: English Installation Manual Model 2700 Analyzer Purge Assembly i User and Installation Manual Ref: 335A2014/335A2010/335A1023

More information

Technical specification. Stabilizer WR 2000 XL

Technical specification. Stabilizer WR 2000 XL Technical specification Stabilizer WR 2000 XL Technical specification Working width max. Working depth * 1 Milling and mixing rotor Tool spacing Stabilizer WR 2000 XL 7 10 (2,400 mm) 0 20 (0 500 mm) 13

More information

E-15 Uninterruptible Power Systems (UPS)

E-15 Uninterruptible Power Systems (UPS) Guideline No.E-15 (201510) E-15 Uninterruptible Power Systems (UPS) Issued date:20 October, 2015 China Classification Society Foreword This Guide is a part of CCS Rules, which contains technical requirements,

More information

WATERFLUX 3070 Quick Start

WATERFLUX 3070 Quick Start WATERFLUX 3070 Quick Start Battery powered electromagnetic water meter Electronic Revision ER 4.3.0_ up to ER 4.3.4_ (SW.REV 4.2.2_ up to 4.2.5_) KROHNE CONTENTS WATERFLUX 3070 1 Safety instructions 4

More information

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET.

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET. MICROBIOLOGICAL SAFETY CABINETS CLASS II MICROBIOLOGICAL SAFETY CABINET CLEAN TECHNOLOGY FOR A CLEAN ENVIRONMENT - THE CLEAN GENERATION Envair eco safe Comfort Plus Safety Cabinets belong to the latest

More information

Air-Cooled Screw Compressor Chiller

Air-Cooled Screw Compressor Chiller Installation, Operation and Maintenance Manual IOMM ALS Group: Chiller Part Number: 070774401 Date: February 1998 Supersedes: IM 548-3 Air-Cooled Screw Compressor Chiller ALS 070A through 425A 60 Hertz

More information

Ball valve C 10 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 10 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C 0 valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and cannot be flushed

More information

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure Smoke extraction F200/120 and F400/120 A complete range from 1250 to 95000 m 3 /s High available pressure Blade with variable pitch on stop APPLICATION Extraction or introduction of non-loaded air in the

More information

Angle seat valve with diaphragm actuator VZXA-...-M

Angle seat valve with diaphragm actuator VZXA-...-M Angle seat valve with diaphragm actuator VZXA-...-M Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com

More information

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000 OPERATION INSTRUCTIONS HORIZONTAL SELF-SUCTION FILLER SERIES GFA-W-10\300\00\1000 Please operate in accordance with the instructions strictly. CONTENTS Overview Maintenance and Service Application Replacement

More information

AIR LUBRICATION SYSTEM INSTALLATION

AIR LUBRICATION SYSTEM INSTALLATION Guide for Air Lubrication System Installation GUIDE FOR AIR LUBRICATION SYSTEM INSTALLATION OCTOBER 2018 American Bureau of Shipping Incorporated by Act of Legislature of the State of New York 1862 2018

More information

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

Cytotoxic Safety Cabinets ENVAIR eco safe Plus Cytotoxic Safety Cabinets ENVAIR eco safe Plus Class Cytotoxic Standard Width (m) II Safety EN 12469 0.9 / 1.2 Cabinet DIN 12980 1.5 / 1.8 Clean technology for a clean environment ENVAIR eco safe Plus

More information

Technical specification for NDA 40 NO Rescue Boat Davit

Technical specification for NDA 40 NO Rescue Boat Davit Technical specification for NDA 40 NO Rescue Boat Davit 1.06.014 Weight information added PGO ESO GNI 1 18.06.013 Re issued for construction PGO GNI GNI 0 Issued for construction PGO GNI GNI REV.: DATE:

More information

Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science

Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science Pneumatic and Electro-pneumatic components: No. EQUIPMENTS operating

More information

Angle seat valve with piston actuator VZXA-...-K

Angle seat valve with piston actuator VZXA-...-K Angle seat valve with piston actuator VZXA-...-K Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com

More information

Electric. PN April Series Electric Oven

Electric. PN April Series Electric Oven Electric PN April 2013 Series Electric Oven E NOTICE: This Owner s Operating and Installation Manual should be given to the user. The operator of the oven should be familiar with the operation of the oven.

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH PrioVino Premier Translation of Original Operating Instructions Status: August 2018 First edition January 2018 / PrioVino GmbH Reprint even in extracts only upon written permission by PrioVino GmbH (ISO

More information

Technical specifications EF Food Processing Equipment for the Gambia. Section 1: Cashew/peanut roasting and peanut flour making

Technical specifications EF Food Processing Equipment for the Gambia. Section 1: Cashew/peanut roasting and peanut flour making Annex B Technical Specifications 2018-12-EF Food Processing Equipment for the Gambia Section 1: Cashew/peanut roasting and peanut flour making Automatic groundnut roasting machines Purpose of the machine

More information

ASALAIR BIOHAZARD ATLANTIC CABINET MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2

ASALAIR BIOHAZARD ATLANTIC CABINET MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2 ASAL S.R.L. - APPARECCHI SCIENTIFICI ATTREZZATURE LABORATORI Quality System comply with requirements of UNI EN ISO 9001:2008. Certificate TÜV Italia n 50 100 3290 Rev. 04 ASALAIR BIOHAZARD ATLANTIC CABINET

More information

Specifications for New Underground Mobile Mining Equipment Underground Mobile Equipment Major Hazard Standard

Specifications for New Underground Mobile Mining Equipment Underground Mobile Equipment Major Hazard Standard WMC Environment, Health & Safety Management System Specifications for New Underground Mobile Mining Underground Mobile Major Hazard Standard MHS-05 DocsOpen Ref: 57401, 03/03/1999 Uncontrolled copy check

More information

Installation Instructions

Installation Instructions GEMINI SELECT 38APS025-065, 38APD025-130 Air-Cooled Condensing Units with PURON Refrigerant (R-410A) 50/60 Hz Installation Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................

More information

A E R Z E N S C R E W C O M P R E S S O R S

A E R Z E N S C R E W C O M P R E S S O R S A E R Z E N S C R E W C O M P R E S S O R S AERZEN - DELTA TWIN - Two Stage Screw Compressors Oil free compressed air technology A E R Z E N E R M A S C H I N E N F A B R I K G M B H V1-016 01 EN 2000

More information

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES SPECIFICATION #01 TYPE I AMBULANCE 2 WHEEL DRIVE 4 WHEEL DRIVE OPTIONAL (DIESEL ENGINE, DUAL REAR WHEEL,

More information

Automatic Island Model "DA 2500" built for the casting gravity of aluminum parts.

Automatic Island Model DA 2500 built for the casting gravity of aluminum parts. Automatic Island Model "DA 2500" built for the casting gravity of aluminum parts. 1 Gravity die casting Machine DA 2500 FR 8 Safety photocell and panel casting area 2 Manipulator load sand core 9 Safety

More information

Butterfly Valve K 220 for application in the harsh environment of the chemical industry

Butterfly Valve K 220 for application in the harsh environment of the chemical industry Butterfly Valve K 220 for application in the harsh environment of the chemical industry Advantage DN 20 to DN 400 liner as a element liner makes additional flange seals superfluous cost efficient and direct

More information

MINI POWER PACKS WITH SUBMERSED MOTOR AND PUMP

MINI POWER PACKS WITH SUBMERSED MOTOR AND PUMP MINI POWER PACKS WITH SUBMERSED MOTOR AND PUMP CMI Summary table Essential characteristic of the control unit compact CMI is the arrangement of the motor pump unit completely immersed in the oil inside

More information

ABS lifting station Synconta

ABS lifting station Synconta 15975187GB (03/2006) 106800 GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions 601 801 901 901L 902 902L Contents 1 General... 3 1.1 Application areas...

More information

EMERGENCY GENERATOR SET

EMERGENCY GENERATOR SET PART 8.1: EMERGENCY GENERATOR SET PART 1 - GENERAL I SCOPE A. This specification covers the design, furnishing, installation and start up of a factory built, production tested, operable, liquid cooled

More information

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel: Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation

More information

Recirculating Coolers

Recirculating Coolers SELECTION GUIDE (General Models) (Low Temp. Models) (Advanced Low Temp. Models) (High Temp. Models) General Models Low Temp. Models Advanced Low Temp. Models High Temp. Models HX-20 Working Cooling Temp.

More information

English version of. Executive Order on vehicles' technical compatibility with the rail network (Bekendtgørelse nr af 30. november 2012) Preface

English version of. Executive Order on vehicles' technical compatibility with the rail network (Bekendtgørelse nr af 30. november 2012) Preface English version of Executive Order on vehicles' technical compatibility with the rail network (Bekendtgørelse nr. 1127 af 30. november 2012) Preface Please note that the English version is for informational

More information

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates Issued 2005/06/01 Section 16239 Power Generation to 30 kw Page 1 of 7 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01355 Waste Management and Disposal..2 Section 01810 Commissioning..3 Section 03100 Concrete

More information

Technical specifications

Technical specifications KINGDOM OF SAUDI ARABIA THE SAUDI FUND FOR DEVELOPMENT ( SFD) ITB -207-7 Technical specifications Project name: Reconstruction, Furniture and Equipping of Three Schools Photovoltaic Solar System for Holly

More information

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA KVA POWERHOUSE RANGE 1250 KVA 1700 KVA 50 hz Three phase 380-415 v Model Engine Alternator Manufacturing country of engine & alternator PRP Output ESP Output Kva Kw Kva 380v/400- Kw 415v 46TWG2A PI734B

More information

BRC

BRC ------------------------------------------------------------- Enclosed climate beam for cooling, heating and ventilation CLIMATE BEAM is an enclosed climate beam with integrated circulation air openings

More information