Power Contactor with Mirror Contacts

Size: px
Start display at page:

Download "Power Contactor with Mirror Contacts"

Transcription

1 LLAME SN COSTO Force-Guided Relays Power Contactor with Mirror Contacts Contents Selection Guide 2 Force-Guided Relays G7SA G7S- -E 3 8 Power Contactor with Mirror Contacts J7KNA-AR G7Z

2 LLAME SN COSTO Force-Guided Relays & Power Contactors Selection Guide FGR For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Selecting the Best Device for Your Application How much current does your application require? 10 A or more G7Z p A or less Do you prefer twopiece construction with separate module and socket? yes G7SA p. 3 Rapid delivery product G7S- -E p. 8 no J7KNA-AR p. 11 Rapid delivery product Force-Guided Relays Relay Series Construction Mounting Poles G7SA G7S- -E Socket & Module Socket & Module Rated Carry Current Solenoid Voltage Built in Coil Supression LED ndicator Catalog Page Number DN Rail/PCB A 24 VDC Optional 3 DN Rail/PCB A 24 VDC 8 Power Relays with Mirror Contacts Mirror contacts are approved for monitoring of Safety Circuits. Relay Series Construction Mounting Poles Rated Carry Current J7KNA-AR Modules DN Rail A Solenoid Voltage 24 VDC, 110 VAC, 230 VAC Built in Coil Supression 24 VDC models only LED ndicator Catalog Page Number 11 G7Z Modules DN Rail 6 40 A VDC 15 2

3 Force-Guided Relays G7SA LLAME SN COSTO Compact, Slim Relays Conforming to EN Standards Relays with forcibly guided contacts (EN50205 Class A, certified by VDE) Supports the CE marking of machinery (Machinery Directive) Helps avoid hazardous machine status when used as part of an interlocking circuit Four-pole and six-pole Relays are available The relay s terminal arrangement simplifies PWB pattern design Reinforced insulation between inputs and outputs. Reinforced insulation between some poles of different polarity. A Rapid Delivery Product: Select models are available for shipment today or within 3 to 5 days G7SA For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. C US Specifications Ratings Coil Rated Voltage Rated Current (ma) Coil Resistance (Ω) Must Operate Voltage (V) Must Release Voltage (V) Max. Voltage (V) Power Consumption (mw) 24 VDC 4 poles: 15 6 poles: poles: 1,600 6 poles: 1,152 75% max. 10% min. 110% 4 poles: Approx poles: Approx. 500 Notes: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of ±15%. 2. Performance characteristics are based on a coil temperature of 23 C. 3. The maximum voltage is based on an ambient operating temperature of 23 C maximum. Contacts Resistive Load Rated load 6 A at 250 VAC, 6 A at 30 VDC Rated carry current 6 A Max. switching voltage 250 VAC, 125 VDC Max. switching current 6 A Max. drop-out time* 10 ms *The drop-out time is the time it takes for the N/O contacts to open after the coil voltage is turned OFF. Certified Standards EN Standards, VDE Certified EN (Electromechanical non-specified time all-or-nothing relays) EN50205 (Relays with forcibly guided (linked) contacts) UL standard UL508 ndustrial Control Devices CSA standard CSA C22.2 No. 14 ndustrial Control Devices Forcibly-Guided Contacts (from EN50205) f an NO contact becomes welded, all NC contacts will maintain a minimum distance of 0.5 mm when the coil is not energized. Likewise if an NC contact becomes welded, all NO contacts will maintain a minimum distance of 0.5 mm when the coil is energized. Characteristics of Sockets Model Continuous Current Dielectric Strength nsulation Resistance P7SA-1 6 A *1 2,500 VAC for 1 min. between poles 1,000 MΩ min. *2 Select models are available for Rapid Delivery. Visit this product on for details. Notes: Use the P7SA-1 F-ND in the ambient temperature range of -20 to 70 C. Use the P7SA-1 F and P7SA-1 F-ND in the ambient humidity range of 45 to 85%. *1. When operating the P7SA-1 F at a temperature between 55 and 85 C, reduce the continuous current (6 A at 55 C or less) by 0.1 A for each degree above 55 C. When operating the P7SA-1 F-ND at a temperature between 50 and 70 C, reduce the continuous current (6 A at 50 C or less) by 0.3 A for each degree above 50 C. *2. Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC. 3

4 LLAME SN COSTO G7SA Force-Guided Relays Engineering Data Durability Curve No. of operations ( 10 4 operations) 1, DC13, 24 VDC AC15, 240 VAC DC1, 24 VDC AC1, 240 VAC Contact current (A) Dimensions (mm) G7SA-3A1B G7SA-2A2B 40 max. 13 max. Terminal Arrangement/ nternal Connection Diagram (Bottom View) G7SA-3A1B Printed Circuit Board Design Diagram (Bottom View) (±0.1 tolerance) Ten, 1.4 dia max G7SA-2A2B Notes: 1. Terminals 23-24, 33-34, and are normally open. Terminals and are normally closed. 2. The colors of the cards inside the Relays are as follows: G7SA- 3A1B: Blue and G7SA-2A2B: White. G7SA-5A1B G7SA-4A2B G7SA-3A3B Terminal Arrangement/ nternal Connection Diagram (Bottom View) G7SA-5A1B Printed Circuit Board Design Diagram (Bottom View) (±0.1 tolerance) Fourteen, 1.4 dia. 50 max. 13 max max. 3.5 G7SA-4A2B G7SA-3A3B Notes: 1. Terminals 23-24, 33-34, 43-44, 53-54, and are normally open. Terminals 11-12, 21-22, and are normally closed. 2. The colors of the cards inside the Relays are as follows: G7SA- 5A1B: Blue, G7SA-4A2B: White, and G7SA-3A3B: Yellow. Select models are available for Rapid Delivery. Visit this product on for details. 4

5 LLAME SN COSTO G7SA Force-Guided Relays Dimensions (continued) (mm) Track-mounting Socket P7SA-10F, P7SA-10F-ND Terminal Arrangement/nternal Connection Diagram (Top View) G7SA-3A1B Mounted G7SA-2A2B Mounted * * max. 5 2R 22.5 max. Ten, M max Mounting Hole Placement Diagram (Top View) Two, 4 dia. or M3.5 * This display circuit is available only for "-ND" models. Note: Terminals 23-24, 33-34, and are normally open. Terminals and are normally closed. 72 max. LED indicator 9 max. 4 dia. Note 1: The socket is shown with the finger cover removed. 2: Only the -ND Sockets have LED indicators (orange) Track-mounting Socket P7SA-14F, P7SA-14F-ND Terminal Arrangement/nternal Connection Diagram (Top View) G7SA-5A1B Mounted G7SA-4A2B Mounted G7SA-3A3B Mounted * * * max. 5 2R 30 max. Fourteen, M max max. LED indicator Mounting Hole Placement Diagram (Top View) Two, 4 dia. or M3.5 * This display circuit is available only for "-ND" models. Note: Terminals 23-24, 33-34, 43-44, 53-54, and are normally open. Terminals 11-12, 21-22, and are normally closed. 9 max. 4 dia. Note 1: The socket is shown with the finger cover removed. 2: Only the -ND Sockets have LED indicators (orange). Select models are available for Rapid Delivery. Visit this product on for details. 5

6 LLAME SN COSTO G7SA Force-Guided Relays Dimensions (continued) (mm) Back-mounting Socket (for PCB) P7SA-10P max max. Terminal Arrangement/nternal Connection Diagram (Bottom View) Mounting Hole Placement (Bottom View) (±0.1 tolerance) G7SA-3A1B Mounted max Three, 3.2 dia. (for M3 tapping screws) G7SA-2A2B Mounted (11.1) 0.4 (11.1) 3.5 Ten, 1.1 dia. Three, 2.6 dia. (for M3 tapping screws) Note: Terminals 23-24, 33-34, and are normally open. Terminals and are normally closed. Back-mounting Socket (for PCB) P7SA-14P max. 0.5 Terminal Arrangement/nternal Connection Diagram (Bottom View) Mounting Hole Placement (Bottom View) (±0.1 tolerance) 15 max max. G7SA-5A1B Mounted Fourteen, 1.1 dia. Three, 3.2 dia. (for M3 tapping screws) G7SA-4A2B Mounted (11.1) 0.4 (11.1) Three, 2.6 dia. (for M3 tapping screws) G7SA-3A3B Mounted Note: Terminals 23-24, 33-34, 43-44, 53-54, and are normally open. Terminals 11-12, 21-22, and are normally closed. Select models are available for Rapid Delivery. Visit this product on for details. 6

7 LLAME SN COSTO G7SA Force-Guided Relays Ordering Model Number Legend G7SA A B NO Contact Poles 2: DPST-NO 3: 3PST-NO 4: 4PST-NO 5: 5PST-NO 2 NC Contact Poles 1: SPST-NC 2: DPST-NC 3: 3PST-NC Relays with Forcibly Guided Contacts Type Sealing Poles Contact Configuration Rated Voltage* Model 4 poles 3PST-NO, SPST-NC G7SA-3A1B DC24 DPST-NO, DPST-NC G7SA-2A2B DC24 Standard Flux-tight 5PST-NO, SPST-NC 24 VDC G7SA-5A1B DC24 6 poles 4PST-NO, DPST-NC G7SA-4A2B DC24 3PST-NO, 3PST-NC G7SA-3A3B DC24 *Consult your Omron representative for details on rated voltages of 12 VDC, 18 VDC, 21 VDC and 48 VDC. Sockets Type LED ndicator Poles Rated Voltage Model 4 poles P7SA-10F No poles P7SA-14F Track-mounting Track mounting and screw mounting possible 4 poles P7SA-10F-ND DC24 Yes 24 VDC 6 poles P7SA-14F-ND DC24 4 poles P7SA-10P Back-mounting PCB terminals No poles P7SA-14P Relays with Forcibly Guided Contacts and Track Mounting Sockets (assemblies) Poles Relay Specifications Contact Configuration Rated Coil Voltage Type Socket Specifications LED ndicator LED Rated Voltage Assembly Model 4 poles DPST-NO, DPST-NC 24 VDC Track Mounting and screw mounting possible No FGRMS poles 3PST-NO, SPST-NC 24 VDC Track Mounting and screw mounting possible No FGRMS poles 3PST-NO, 3PST-NC 24 VDC Track Mounting and screw mounting possible No FGRMS poles 4PST-NO, 2PST-NC 24 VDC Track Mounting and screw mounting possible No FGRMS poles 5PST-NO, SPST-NC 24 VDC Track Mounting and screw mounting possible No FGRMS poles DPST-NO, DPST-NC 24 VDC Track Mounting and screw mounting possible Yes 24 VDC FGRMS22-24-LED 4 poles 3PST-NO, SPST-NC 24 VDC Track Mounting and screw mounting possible Yes 24 VDC FGRMS31-24-LED 6 poles 3PST-NO, 3PST-NC 24 VDC Track Mounting and screw mounting possible Yes 24 VDC FGRMS33-24-LED 6 poles 4PST-NO, 2PST-NC 24 VDC Track Mounting and screw mounting possible Yes 24 VDC FGRMS42-24-LED 6 poles 5PST-NO, SPST-NC 24 VDC Track Mounting and screw mounting possible Yes 24 VDC FGRMS51-24-LED Select models are available for Rapid Delivery. Visit this product on for details. 7

8 Force-Guided Relays G7S- -E LLAME SN COSTO G7SE For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Lineup Now ncludes 10-A Models Relays with forcibly guided contacts (EN50205 Class A, certified by VDE). Supports the CE marking of machinery (Machinery Directive). Helps avoid hazardous machine status when used as part of an interlocking circuit. Track-mounting and Back-mounting Sockets are available. Specifications Ratings Coil Rated Voltage Rated Current (ma) Coil Resistance (Ω) Must Operate Voltage (V) Must Release Voltage (V) Max. Voltage (V) Power Consumption (W) 24 VDC % max. 10% min. 110% Approx. 0.8 Notes: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of ±15%. 2. Performance characteristics are based on a coil temperature of 23 C. 3. The maximum voltage is based on an ambient operating temperature of 23 C maximum. Contacts Rated load NO contact NC contact NO contact Rated carry current NC contact Maximum switching voltage Maximum switching NO contact current NC contact Resistive load nductive load * 10 A at 250 VAC 10 A at 30 VDC 6 A at 250 VAC 6 A at 30 VDC 10 A 6 A 250 VAC, 30 VDC 10 A 6 A AC-15: 5 A at 240 VAC DC-13: 2 A at 24 VDC AC-15: 3 A at 240 VAC DC-13: 2 A at 24 VDC *n the above table, cosø = 0.3 for AC-15 inductive loads and L/R = 96 ms for DC-13 inductive loads. Certified Standards EN Standards, VDE Certified EN (Electromechanical non-specified time all-ornothing relays) EN (Contact performance) EN50205 (Relays with forcibly guided (linked) contacts) UL standard UL508 ndustrial Control Devices CSA standard CSA C22.2 No. 14 (ndustrial Control Equipment) Forcibly-Guided Contacts (from EN50205) f an NO contact becomes welded, all NC contacts will maintain a minimum distance of 0.5 mm when the coil is not energized. Likewise if an NC contact becomes welded, all NO contacts will maintain a minimum distance of 0.5 mm when the coil is energized. Characteristics of Sockets Model Continuous Current Dielectric Strength nsulation Resistance P7S A 2,000 VAC for 1 min. between poles 1,000 MΩ min. * Notes: Use the P7SA-14F-END in the ambient temperature range of 35 to 85% *Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC. 8

9 LLAME SN COSTO G7S- -E Force-Guided Relays Dimensions (mm) G7S-4A2B-E G7S-3A3B-E 62 max max. Terminal Arrangement/nternal Connection Diagram (Bottom View) G7S-4A2B-E VDC 37 max Mounting Hole Dimensions min. G7S-3A3B-E 8± ± VDC Fourteen, 1.8 dia ±0.1 35±0.1 7± Track-mounting Socket P7S-14F-END ndicator Fourteen, M3.0 8 Terminal Arrangement/nternal Connection Diagram (Top View) 40 max. 33± Mounting Hole Dimensions max ±0.1 Two, M3.5- or 4.0-dia. holes 5 (5) 90.5 max Back-mounting Socket (PCB Terminals) P7S-14P-E 23.5 max max. 28±0.2 Two, 6.5 dia. 8 depth Terminal Arrangement/nternal Connection Diagram (Bottom View) With G7S-4A2B-E mounted Mounting Hole Dimensions ± (21) (16.9) With G7S-3A3B-E mounted max. Fourteen, 2.5 dia =35 7 Two, 3.6 dia =35 7 (15) max

10 LLAME SN COSTO G7S- -E Force-Guided Relays Ordering Model Number Legend G7S A B E NO Contact Poles 3: 3PST-NO 4: 4PST-NO 2 NC Contact Poles 2: DPST-NC 3: 3PST-NC Relays with Forcibly Guided Contacts Type Poles Contact Configuration Rated Voltage* Model Standard 6 poles 4PST-NO, DPST-NC 3PST-NO, 3PST-NC 24 VDC G7S-4A2B-E G7S-3A3B-E Sockets Type Rated Voltage Model Track-mounting Common for track mounting and screw mounting 24 VDC P7S-14F-END Back-mounting PCB terminals --- P7S-14P-E 10

11 R LLAME SN COSTO Power Contactor with Mirrored Contacts J7KNA-AR J7KNA For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Mini Contactor Relays 4-Pole AC and DC operated 4-, 6- and 8-pole versions in different configurations Mirrored contacts Screw fixing and snap fitting (35 mm DN rail) Rated current = 10A (th) Suitable for electronic devices (DN 19240) Finger proof (VBG 4) A Rapid Delivery Product: Select models are available for shipment today or within 3 to 5 days Accessories 2- and 4-pole additional auxiliary contacts in different configurations C US Specifications Electrical Operating Coil Supply Power: 24 VDC, 110 VAC or 230 VAC nrush: 25 VA for AC versions 3 W for DC versions Power Usage: 4.5 VA for AC versions 2.5 W for DC versions Rated Carry Current: 10 40C Switching Capability nductive Loads (AC-15, DC-13) AC: Break 120 V - 6 A, 240 V - 3 A (continuous 10 A) DC: 24 V - 3 A Max. Switching Frequency: 10,000 per hour Min. Switching Current: 5 ma Max. Drop-Out Time*: 8-25 ms for AC versions 8-25 ms for DC versions Mechanical Mechanical Life: 1 x 10 7 operations min. Mounting: 35 mm DN rail or 4 screw holes for panel mounting Wire Size: Screw terminals accept two 14 AWG solid or stranded wires Weight: AC versions: 160 g (5 oz.) DC versions: 190 g (6 oz.) Vibration: 5 to 300 Hz Environmental Vibration Resistance: 2 g with control relay open; 4 g with control relay closed Operating Temperature: -40 to 60 C (-40 to 140 F) Approvals: EC , VDE 0660, EN , UL508 *The Drop-Out Time is the time it takes for the N/O contacts to open after the coil voltage is turned OFF. Specifications are subject to change without notice. Approved Standards Standard Guide No. (US,C) UL NKCR, NKCR7 CE VDE 0660 EN Select models are available for Rapid Delivery. Visit this product on for details. 11

12 LLAME SN COSTO J7KNA-AR Power Contactor with Mirrored Contacts Dimensions (mm) AC and DC Operated with Screw Terminals J7KNA-AR Auxiliary Contact Blocks J73KN-A Contact Diagrams Mini Contactor Relays, 4-Pole J7KNA-AR-40 J7KNA-AR-31 J7KNA-AR-22 Auxiliary Contact Blocks for Contactor Relays J7KNA-AR J73KN-A-11 J73KN-A-02 J73KN-A-40 J73KN-A-22 Select models are available for Rapid Delivery. Visit this product on for details. 12

13 LLAME SN COSTO J7KNA-AR Power Contactor with Mirrored Contacts Mirror Contacts Safety Function with Mirror Contacts EN certification for mirror contact mechanisms has been obtained by using a combination of a relay and auxiliary contact blocks (5 VDC, 1 ma), enabling application in feedback circuits of safety circuits. Application Example: General Safety Circuit G9SA-301 (24-V AC/DC) (two limit switch input channels with manual reset) Feedback Circuit Feedback loop Open TH SA Control circuit Mirror Contact Mechanism By combining a Relay with an auxiliary contact block, all NC contacts of the auxiliary contact block will satisfy an impulse withstand voltage of 2.5 kv or higher or maintain a gap of 0.5 mm or greater when the coil is de-energized even if at least one NO contact (main contact) of the Relay is welded. mpulse withstand voltage: 2.5 kv min. or contact separation (a + b): 0.5 mm min. a b Auxiliary contact block NC NC Relay NO NO NO NO Contact welding Select models are available for Rapid Delivery. Visit this product on for details. 13

14 LLAME SN COSTO J7KNA-AR Power Contactor with Mirrored Contacts Ordering Model Number Legend Mini Contactor Relays J7KNA AR Combination of NO/NC Contacts 22: 2 NO/2 NC 31: 3 NO/1 NC 40: 4 NO 2 Coil Voltage (AC operated) 24: AC 24 V 50/60 Hz 110: AC V 50 Hz, AC V 60 Hz 230: AC V 50 Hz, AC 240 V 60 Hz Coil Voltage (DC operated) 24VS: 24 VDC with suppression Auxiliary Contact Modules for Mini Motor Contactor Relays J73KN A 1 1 Combination of NO/NC Contacts 11: 1 NO/1 NC 02: 2 NC 22: 2 NO/2NC 40: 4 NO Model Coil Voltage Contacts Part No. AC Operated Relays J7KNA-AR VAC 4 N/O J7KNA-AR VAC 3 N/O + 1 N/C J7KNA-AR VAC 2 N/O + 2 N/C J7KNA-AR VAC 4 N/O J7KNA-AR VAC 3 N/O + 1 N/C J7KNA-AR VAC 2 N/O + 2 N/C J7KNA-AR VAC 4 N/O J7KNA-AR VAC 3 N/O + 1 N/C J7KNA-AR VAC 2 N/O + 2 N/C DC Operated Relays (coil suppression built -in) J7KNA-AR-40 24VS 24 VDC 4 N/O J7KNA-AR-31 24VS 24 VDC 3 N/O + 1 N/C J7KNA-AR-22 24VS 24 VDC 2 N/O + 2 N/C Auxillary Contact Modules J73KN-A-11 1 N/C + 1 N/O J73KN-A-02 2 N/C J73KN-A-40 4 N/O J73KN-A-22 2 N/O + 2 N/C Select models are available for Rapid Delivery. Visit this product on for details. 14

15 LLAME SN COSTO Power Contactor with Mirror Contacts G7Z G7Z For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Multi-pole Power Relay for Contactor Current Range Capable of Carrying and Switching 40 A at 440 VAC One pole, 40 A can be carried and switched. The maximum load capacity of 160 A when using 4-pole parallel connections. All materials used are compliant with the RoHS Directive EN certification for mirror contact mechanisms has been obtained by using a combination of the relay and auxiliary contact blocks. A design with a small number of openings makes it difficult for dust or foreign matter to enter. deal for supply power to industrial inverters, servo drivers, and other devices, and switching power to motors and other equipment. Specifications Approved Standards UL Standard: UL508, UL840 (File No. E41643) Model G7Z Coil Ratings 12, 24 VDC *Auxiliary contact ratings NO contact NC contact Number of Test Contact Ratings Operations 40 A, 480 VAC, 60 Hz 80,000 (Resistive) 5 A, 120 VDC (Resistive) 100, A, 480 VAC, 60 Hz 100,000 (General Use) D300* (1-A current applied) A, 480 VAC, 60 Hz (Resistive) 5 A, 120 VDC (Resistive) 100, A, 480 VAC, 60 Hz (General Use) D300* (1-A current applied) --- CSA Standard: CSA Certification: CSA C22.2 No. 14 EN Standard/TÜV Certification: EN (Certification No. R ) Model Coil Ratings Contact Ratings G7Z 12, 24 VDC G73Z --- *Auxiliary contact ratings NO contact NC contact NO contact NC contact AC-1: 40 A, 440 V, 50/60 Hz AC-3: 16 A, 440 V, 50/60 Hz DC-1: 5 A, 110 V *AC-15: 0.5 A, 440 V, 50/60 Hz *DC-13: 0.5 A, 110 V AC-1: 25 A, 440 V, 50/60 Hz DC-1: 5 A, 110 V *AC-15: 0.5 A, 440 V, 50/60 Hz *DC-13: 0.5 A, 110 V AC-15: 0.5 A, 440 V, 50/60 Hz DC-13: 0.5 A, 110 V Model G73Z NO contact NC contact Contact Ratings D300 (1-A current applied) Reference nformation UL 508: ndustrial control devices UL 840: nsulation coordination including clearance and creepage distance for electrical devices CSA C22.2 No. 14: ndustrial control devices EN : Contactors 15

16 LLAME SN COSTO G7Z Power Contactor with Mirror Contacts Specifications (continued) Ratings Coil Rated Voltage Rated Current (ma) Coil Resistance (Ω) 12 VDC VDC Must operate Voltage Must release Voltage Percentage of Rated Voltage Maximum Voltage Power Consumption (W) 75% max. 10% min. 110% Approx. 3.7 Notes: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of ±15%. 2. Operating characteristics were measured at a coil temperature of 23 C. 3. The maximum allowable voltage is the maximum value of the fluctuation range from the relay coil operating power supply and was measured at an ambient temperature of 23 C. There is, however, no continuous allowance. Contacts Relay Contact structure Contact material Rated load NO NC G7Z-4A- Z, G7Z-3A1B- Z, G7Z-2A2B- Z Resistive load 40 A at 440 VAC 25 A at 440 VAC nductive load cosø = 0.3 Double break Ag alloy 22 A at 440 VAC 10 A at 440 VAC 40 A 25 A Resistive load L/R = 1 ms 5 A at 110 VDC 5 A at 110 VDC NO Rated carry current NC Maximum contact voltage 480 VAC 125 VDC Maximum contact NO 40 A 22 A 5 A current NC 25 A 10 A 5 A Maximum switching NO 17,600 VA 9,680 VA 550 W capacity NC 11,000 VA 4,400 VA 550 W Failure rate P value 2 A at 24 VDC (reference value) Note: The ratings for the auxiliary contact block mounted on the G7Z are the same as those for the G73Z auxiliary contact block. Auxiliary Contact Block Contact structure Contact material Rated load G73Z-20Z, G73Z-11Z, G73Z-02Z Resistive load 1 A at 440 VAC nductive load cosø = 0.3 Double break Au clad + Ag 0.5 A at 440 VAC 1 A Resistive load L/R = 1 ms 0.5 A at 110 VDC Rated carry current Maximum contact voltage 480 VAC 125 VDC Maximum contact current 1 A 0.5 A Maximum switching capacity 440 VA 220 VA 55 W Failure rate P value (reference value) 1 ma at 5 VDC 16

17 LLAME SN COSTO Mirror Contacts Safety Function with Mirror Contacts EN certification for mirror contact mechanisms has been obtained by using a combination of a relay and auxiliary contact blocks (5 VDC, 1 ma), enabling application in feedback circuits of safety circuits. Application Example: General Safety Circuit G9SA-301 (24-V AC/DC) (two limit switch input channels with manual reset) Feedback Circuit Feedback loop Open TH SA Control circuit Mirror Contact Mechanism By combining a Relay with an auxiliary contact block, all NC contacts of the auxiliary contact block will satisfy an impulse withstand voltage of 2.5 kv or higher or maintain a gap of 0.5 mm or greater when the coil is de-energized even if at least one NO contact (main contact) of the Relay is welded. mpulse withstand voltage: 2.5 kv min. or contact separation (a + b): 0.5 mm min. a b Auxiliary contact block NC NC Relay NO NO NO NO Contact welding 17

18 LLAME SN COSTO G7Z Power Contactor with Mirror Contacts Dimensions Relay (12 VDC, 24 VDC) with Auxiliary Contact Block 4 Poles (mm) Mounting Hole Dimensions Two, M ± Four, M Eight, M Two, M Auxiliary Contact Block Four, M DN Track Mounting Height (when using PFP-100N or PFP-50N mounting rail) Note: The dimensions are typical values. 18

19 LLAME SN COSTO G7Z Power Contactor with Mirror Contacts Ordering Model Number Legend Relay with Auxiliary Contact Block G7Z Relay Contact Configuration 4A: 4PST-NO 3A1B: 3PST-NO/SPST-NC 2A2B: DPST-NO/DPST-NC 2 Contact Configuration of Auxiliary Contacts 20: DPST-NO 11: SPST-NO/SPST-NC 02: DPST-NC 3 Contact Mechanism of Auxiliary Contacts Z: Bifurcated crossbar contact Auxiliary Contact Block G73Z Contact Configuration of Auxiliary Contacts 20: DPST-NO 11: SPST-NO/SPST-NC 02: DPST-NC 2 Contact Mechanism of Auxiliary Contacts Z: Bifurcated crossbar contact Relay with Auxiliary Contact Block Relay with Auxiliary Contact Block (for Screw Terminals) Classification Relay Contact configuration Auxiliary Contact Block Rated Voltage Model DPST-NO G7Z-4A-20Z 4PST-NO SPST-NO/SPST-NC G7Z-4A-11Z Relay with Auxiliary Contact Block 4 poles + 2 poles 3PST-NO/SPST-NC DPST-NC DPST-NO SPST-NO/SPST-NC DPST-NC 12, 24 VDC G7Z-4A-02Z G7Z-3A1B-20Z G7Z-3A1B-11Z G7Z-3A1B-02Z DPST-NO G7Z-2A2B-20Z DPST-NO/DPST-NC SPST-NO/SPST-NC G7Z-2A2B-11Z DPST-NC G7Z-2A2B-02Z Notes: 1. Relay contact terminals are M5, and the coil terminals are M Auxiliary contact block terminals are M3.5 Accessories (Order Separately) Auxiliary Contact Block Classification Contact Configuration Model DPST-NO G73Z-20Z Auxiliary Contact Block 2 poles SPST-NO/SPST-NC G73Z-11Z DPST-NC G73Z-02Z 19

20 LLAME SN COSTO Safety Applications OMRON Automation and Safety offers... Application Solutions Transfer Robot Guarding This large industrial robot is used to transfer work in process from one conveyor to another. Moving quickly, it has the potential to seriously injure personnel. ST Universal Safety Mats in conjunction with ST safety mat controllers are designed to protect workers by sending a stop signal to the robot to cease hazardous motion. Test Machine Robot Silicon Wafer Quality Control Stand Full wafer trays are placed in the work cell by the operator reaching through a safety light curtain. Access to the hazardous robot is additionally guarded by hard guarding on three sides which has been interlocked with the MC magnetically coded safety switches. n order to assure that the robot will not start with someone in the enclosure, ST Universal Safety Mats are used inside the perimeter. The hinged guard below the safety light curtain is interlocked using an D4NH hingepin operated safety switch. 20

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit   Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Force-Guided s & Power Contactors For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Multi-pole Power for Contactor Current

More information

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms

More information

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets Safety Relay Safety Relay conforming to EN standard Conforms to pren50205. A minimum of 0.5 mm between contacts even when one contact is welded. (pren50205 Class A) Forcibly guided contacts. The contributes

More information

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed PCB Relay G5LA A Cubic, Single-pole 1A Power Relay Economical cube relay with universal terminal footprint Conforms to VDE435, CQC UL recognized/ CSA certified. High switching power: 1A @ 5VAC Withstands

More information

Model Number Structure

Model Number Structure Power Relay G7J Electromechanical Relays A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Contact form Terminal Single-side stable Single-winding latching PCB Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98 mw pickup coil power. Impulse withstand voltage meets FCC Part 68 requirements. Plastic-sealed construction. Unique moving

More information

Ordering Information. Text PCB Power Relay G5LE

Ordering Information. Text PCB Power Relay G5LE A Cubic, Single-pole 10-A Power Relay Single-pole 10A 35VDC, 0.8mm contact gap: G5LE-G Single-pole 16A 250VAC: G5LE-E ROHS compliant. Sub-miniature sugar cube relay with universal terminal footprint. Conforms

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30

More information

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1 Power PCB Relay Creepage distance of 8.0 mm (0.31 in) min. between coil and contact Dual-winding latching type available Plug-in and quick-connect terminals available High sensitivity (360 mw) and high

More information

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil

More information

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment PCB Relay Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment High sensitivity can be driven by digital circuits. Horizontal design allows use in /2-inch PCB racks.

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (00) 6-0 www.cmafh.com Safety Interlock Switches DSL-N Super Small Class 6-Contact uard Lock Safety-Door Switch

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4JL D4JL For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. uard Lock Safety-Door Switch Holding

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Emergency Stop Devices A22E A22E For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Emergency Stop Switch (22 mm or 25

More information

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC PCB Relay R G5LE-E/-G Single-pole 0A35VDC 0.8mm Contact Gap Power Relay : Single-pole 6A250VAC Power Relay : G5LE-E Sub-miniature 'sugar cube ' relay with universal terminal footprint. UL class-f coil

More information

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals Power Relay A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. No contact

More information

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Exceptionally reliable general purpose relay Long life (minimum 100,000 electrical operations) assured by silver contacts Built-in operation indicator (mechanical, LED), diode surge

More information

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and

More information

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US Hermetically Sealed Relay MY4H Hermetically Sealed Relay Ideal for Hazardous Locations Class 1 Division 2 approved. Fully hermetically sealed for hazardous locations. Cadmium-free contacts for environment-friendly

More information

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12). Low Signal Relay High sensitivity can be driven by digital circuits Low-profile design allows use in 12.70 mm (0.50 in) PC board rack Surge withstand voltage meets FCC Part 68 regulation Units can be mounted

More information

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal PCB Relay Ultracompact, Ultrasensitive DPDT Relay Compact size and low 5-mm profile. Low power consumption (140 mw for single-side stable, 100 to 300 mw for latching type) and high sensitivity. Low thermoelectromotive

More information

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives Safety Interlock Switches DSL Compact -Contact uard Lock Safety-Door Switch Two types are available: a connector type that reduces wiring time and a detachable terminal block type. Robust and durable metal

More information

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection PRODUCT NEWS Product Discontinuation Notices February 1, 2012 Safety Relays No. 2012037E Discontinuation Notice of Safety Relay and Socket., P7S series Product Discontinuation Safety Relay Socket P7S series

More information

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect Two-Hand Controller -mm Wide Two-hand Control Circuit H Two-hand Controller, easy-to-connect Expansion Units available H Positive, force-guided contacts H DIN-rail mounting and panel mounting available

More information

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance

More information

A22NK. Key-type Selector Switches

A22NK. Key-type Selector Switches Key-type Selector Switches -mm dia. Key-type Selector Switches Control panel miniaturization through a more compact design and modified wiring direction. Addition of Push-In Plus terminal blocks for easy

More information

Ordering Information. Text Surface-Mounting Signal Relay G6K

Ordering Information. Text Surface-Mounting Signal Relay G6K Surface-Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm ROHS compliant. Sub-miniature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting.

More information

Model Number Structure

Model Number Structure Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Safety Interlock Switches

Safety Interlock Switches Safety Interlock Switches ATK ATK Safety Key Selector Switch Key-type selector switch with direct opening mechanism Selector Switch for secure equipment activation during maintenance 0 types of exclusive

More information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).

More information

Type Terminal Coil Contact form Model

Type Terminal Coil Contact form Model General Purpose Relay MK Exceptionally reliable general purpose relay. Long life (minimum 100,000 electrical operations) assured by silver contacts. Built-in operation indicator (mechanical, LED), diode

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0 General Purpose Relay LY Arc barrier equipped. High dielectric strength (2,000 VAC). Long dependable service life assured by Ag-Alloy contacts. Choose models with single or bifurcated contacts, LED indicator,

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches DNL DNL For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. uard Lock Safety-Door Switch Best-selling

More information

Lighted Pushbutton Switch

Lighted Pushbutton Switch Lighted Pushbutton Switch General Purpose and Micro-Voltage/Current Load Switch Requires only 22 mm mounting depth All LEDs, lamps, legends and pushbutton units replaceable without tools Oil-resistant

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Arc barrier equipped High dielectric strength (2,000 VAC) Long dependable service life assured by AgCdO contacts Choose models with single or bifurcated contacts, LED indicator, diode

More information

Safety Relay Unit G9S

Safety Relay Unit G9S Safety Relay Unit G9S Ideal for Safety Door and Emergency Stop Switch Circuits Two-pole, three-pole, and five-pole models are available. Basic Models and OFF-delay models are available Incorporates LED

More information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure. Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety

More information

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary drops up to % of rated. Wide-range AC-activated coil that handles 1 to 1 or to

More information

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC PCB Relay Subminiature Relay that Switches up to 5 A Subminiature: 20 10 10 mm (L W H). Low power consumption: 200 mw. Unique moving loop armature reduces relay size, magnetic interference, and contact

More information

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT NC NC RELAYS Flat type Flat type (PC board) (PC board) FEATURES 1. Compact, slim design Use of high-performance flat electromagnetic design achieves 10.9

More information

1 Form A 5A small size power relay for interface

1 Form A 5A small size power relay for interface 1 Form A 5A small size power relay for interface PQ RELAYS RoHS compliant Protective construction: Sealed type FEATURES 1. Compact and slim 20 mm (L) mm (W) 16 mm (H).787 inch (L).394 inch (W).630 inch

More information

Safety Interlock Switches

Safety Interlock Switches Safety Interlock Switches D4BL D4BL uard Lock Safety-Door Switch Release protective cover locks using controller signals or pushbutton switches after the cutting tool stops moving due to inertia A mechanical

More information

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse. Switch A22E Install in 22-dia. or 25-dia. Panel Cutout Direct opening mechanism to open the circuit when the contact welds. Safety lock mechanism prevents operating errors. Easy mounting and removal of

More information

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F 8H Type List 8H Terminal style Contact form Features Miniature PCB Power Relays A 2VAC. High CTI 2 material or product comply with IEC 33-1 are available. UL Insulation Class F. VDE, UL/CUL, TUV, CSA/CUS

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

CAUTION CM-SE CM-S21 CM-S41

CAUTION CM-SE CM-S21 CM-S41 CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm Emergency Stop Switch Mounting Aperture of 16 mm Modular construction, easy installation Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, Conforms to EN418

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit C Conforms to EN94-1, EN1088, EN60204-1 UL and C-UL listed Description R US Compact Coded Magnetic Safety Interlock Switch and Control Unit Dual channel, fully monitored system; meets Category 3 when single

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Designed small, 2- and 3-pole types break 5 A loads and 4-pole type, 3 A load High reliability, long life Ultra-high sensitivity with quick response High vibration/shock resistance

More information

Scheda prodotto Relè Series E

Scheda prodotto Relè Series E Relè Miniatura All-or-Nothing relays ideally suited for any electronic appliances demanding very compact design and low power consumption. Design includes a protective dust cover and a completete range

More information

D4BS CSM_D4BS_DS_E_8_4

D4BS CSM_D4BS_DS_E_8_4 Safety-door Switch CSM DS_E_8_4 The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment

More information

Safety Switches & Operator Controls

Safety Switches & Operator Controls Safety Switches & Operator Controls Contents Selection Guide H-2 Safety Limit Switches Plastic D4N H-4 D4N- R H-12 Safety Limit Switches Metal D4B- N H-13 D4F H-13 Safety Selector Switch A22TK H-14 Enabling

More information

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping) Safety-door Switch D4BS The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment CSM_D4BS_DS_E_6_1

More information

Scheda prodotto Relè Series B

Scheda prodotto Relè Series B Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where

More information

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key Guard Lock Safety-door Switch/Slide key D4JL/D4JL-SK40 C38I-E-02 Holding Force of 3,000 N Two safety circuits and two monitor contacts provide an array of monitoring patterns. Standard gold-clad contacts

More information

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A Main Feature 1. 1 Pole to 4-Poles versions available with switching current at 15A (1 Pole) and 10A (2-4 Poles). 2. Printed Circuit Board Terminal, Plug-in Terminal and Flanged Case are designed for easy

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

General Purpose Relay

General Purpose Relay General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)

More information

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

2c 15A, 4c 10A polarized power relays

2c 15A, 4c 10A polarized power relays c 5A, 4c A polarized power relays SP RELAYS RoHS compliant Protective construction: Dust cover type Taking advantage of the 4-gap balanced armature mechanism, S relays have met a number of relay needs

More information

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi Type List Terminal style WP (High power type, terminals)-.0mm pitch Contact form A (SPNO) Features Low Profile mm w/ fasten terminals. High Rating 7A 277VAC. High temperature withstand up to 2. UL/CUL

More information

Safety Interlock Switches

Safety Interlock Switches Safety Interlock Switches A22E A22E Emergency Stop Switch (22-dia. or 25-dia.) Install in 22-dia. or 25-dia. panel cutout Direct opening mechanism to open the circuit when the contact welds. Safety lock

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

Square D General Purpose Relays

Square D General Purpose Relays Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................

More information

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure Guard Lock Safety-door Switch Environment-friendly Switch with Direct Opening Contacts Contains no harmful substances, such as lead or cadmium, reducing the burden on the environment. Slim safety-door

More information

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key! 655 Door with Key SERIES Related Information General terms and conditions... F-7 General precautions... P.50 PHOTO PHOTO Conforming to Machine & EMC Directives Recognition Certified MEASURE ITY panasonic.net/id/pidsx/global

More information

D4BL. Guard Lock Safety-door Switch

D4BL. Guard Lock Safety-door Switch Guard Lock Safety-door Switch D4BL CSM_D4BL_DS_E_5_1 Release Protective Cover Locks Using Controller Signals or Pushbutton Switches after the Cutting Tool Stops Moving Due to Inertia A mechanical lock

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Hinged Safety Door Switch

Hinged Safety Door Switch Hinged Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. Two actuator types are available: Shaft Arm lever Arm lever type can be adjusted to allow a right (180 ),

More information

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL Terminal Relay Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogramme Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILER-31-G-C(110VDC) Articleno. 231831 CatalogNo. XTRMC10A31E0 Product range DILER Mini-contactors Application Contactor relays Description

More information

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005 Guard Lock Safety-door Switch D4JL World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005 Two safety circuits and two monitor contacts provide an array of monitoring patterns. Standard

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogram Contactorrelay,2N/O+2N/C,DCcurrent Partno. DILER-22-G(220VDC) Articleno. 010091 CatalogNo. XTRM10A22BD Product range DILER Mini-contactors Application Contactor relays Description with

More information

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM FEATURES Plug-in relay Quick connect receptacles or direct soldering. PCB terminals are also acceptable. Large capacity 30A contact rating. Optional blowout magnet: high dc switching. Wide spacing between

More information

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive

More information

HL (AZH) LIMIT SWITCHES

HL (AZH) LIMIT SWITCHES COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Safety-door Switch D4NS. Model Number Structure. Model Number Legend Safety-door Switch D4NS Multi-contact, Labor-saving, Environmentfriendly, Next-generation Safety-door Switch Lineup includes MBB models and three contact models with 2NC/1NC and 3NC contact forms in addition

More information

Function Relays, Interfaces and Converters

Function Relays, Interfaces and Converters Function Relays, Interfaces and Converters Interface Relays Narrow Design 3TX70 interface relays 3TX701 Interface relay, plug-in Plug-in socket interface, complete with relay Contact Rated control Width

More information

T75S5D Product Details

T75S5D Product Details T75S5D112-12 Product Details Industrial Relays (General Purpose) Converted to EU RoHS but not ELV Compliant (Statement of Compliance) T75S5D112-12 TE Internal Number: 1393223-3 Active Product Highlights:

More information

Features. Type List. Ordering Information S - 1A - - C - Contact Rating

Features. Type List. Ordering Information S - 1A - - C - Contact Rating Features Heavy duty A VAC, A VAC power type. AC & DC coils are both available. PCB terminals and quick terminal types. Optional for special large contact gap 3.0mm version. SPNO-ST & DPNO-ST contact configuration.

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Wide selections of actuators, terminals and bodies to meet any application Excellent environmental resistance Die casting caseiec IP67 Plastic caseiec

More information

Industrial Relay KML(1C, 2C)

Industrial Relay KML(1C, 2C) Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations

More information

Surface mounting, flush mounting, and DIN track mounting

Surface mounting, flush mounting, and DIN track mounting Solid-state Timer H3JA Economical, Compact, Plug-in Timer Time limit, ON-delay, operation with automatic resetting. DIN size (36 x 36 mm), fits standard 8-pin sockets. Wide choice of supply voltages: 24,

More information

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1 Motor Timer H2A Miniature, High-performance Motor Timer Employs high-reliability bifurcated contacts for output. Moving pointer provided in all types for confirmation of elapsed time. Employs time-out

More information

D4GL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key

D4GL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key Guard Lock Safety-door Switch D4GL Vertically Mounting Guard Lock Safety-door Switch Ideal for Limited Installation Space Selectable Operation Key insertion direction. Slim safety-door switch with an electromagnetic

More information

Safety Control HR1S-AC. Safety Relay HR1S-AC

Safety Control HR1S-AC. Safety Relay HR1S-AC HRS-AC Safety Relay HRS-AC Key features: NC or 2NC safety input type, such as E-Stops or Interlock Switches EN ISO 3849- PLe, Safety Cat 3 compliant, and EN 6206 SIL 3 Fault diagnosis function with dual

More information