DVG/AF Variable Geometry Desuperheater

Size: px
Start display at page:

Download "DVG/AF Variable Geometry Desuperheater"

Transcription

1 Instruction Manual D101616X012 DVG/AF Desuperheater DVG/AF Variable Geometry Desuperheater Contents Introduction Scope of Manual Description Principle of Operation Installation Maintenance Instructions Servicing Disassembly Assembly Troubleshooting DVG/AF Parts Ordering Parts List Introduction Scope of Manual This instruction manual includes installation, maintenance, and operation information for the DVG/AF variable orifice desuperheater. Refer to separate instruction manuals for information on the actuator and accessories. Do not install, operate, or maintain a DVG/AF desuperheater without first being fully trained and qualified in desuperheater, valve, actuator, and accessory installation, operation, and maintenance, and carefully reading and understanding the contents of this manual. If you have any questions about these instructions, contact your Emerson Process Management sales office before proceeding. Description The DVG/AF variable orifice desuperheater (figure 1) provides a convenient and efficient method of reducing superheated steam, and some other vapors, to desired temperature levels. The variable W6981/IL Figure 1. DVG/AF Variable Geometry Desuperheater with Pneumatic Actuator orifice design allows precise temperature control under widely fluctuating process conditions. The DVG/AF features: 1. Fine atomization over a wide range of operating conditions helping to assure rapid and complete vaporization of injected water. 2. No pipe liners, atomizing steam, or separate spraywater control valves are required. 3. Temperature control to within 6-8 C (10-15 F) of saturation. 4. Simple in line installation is accomplished through a standard flange connection. Installation can be in a vertical-up or horizontal pipe. 5. High turndown capability.

2 DVG/AF Desuperheater Instruction Manual Table 1. Specifications Steam Line Sizes NPS 8 to 60 Steam Line Connection Sizes NPS 3, 4, and 6 CL150, CL300, CL600, CL900, and CL1500 raised-face flange (consult factory for higher ratings) (1) Spraywater Connection Sizes NPS 1, 1-1/2, and 2 CL150, CL300, CL600, CL900, and CL1500 raised-face flange (consult factory for higher ratings) (1) Maximum Inlet Pressures (2) Consistent with applicable CL150, 300, 600, 900, and 1500 (consult factory for higher ratings) pressure-temperature ratings per ASME B16.34 Inherent Rangeability (3) Up to 25:1 Spraywater Pressure Required 3.5 to 35 bar (50 to 500 psig) greater than steam line pressure Minimum Steam Velocity (4) 9.1 meters per second (30 feet per second) Yoke Boss Sizes and Valve Stem Diameters 71mm (2-13/16 inch) yoke boss diameter with 12.7mm (1/2 inch) stem diameter Valve Travel (Standard) 38mm (1.5 inch) 1. Alternate pressure classes may be available. Consult factory. 2. Do not exceed the pressure or temperature limits in this instruction manual, nor any applicable code or standard limitations. 3. Ratio of maximum to minimum controllable C v, dependent on available water pressure differential. 4. Minimum steam velocity is a function of several application parameters and may be adjusted upward or downward from this standard. Principle of Operation The DVG/AF desuperheater reduces steam temperatures by introducing cooling water directly into the hot steam. Heat transfer accomplishes the desired temperature reduction. The cooling water absorbs heat by conduction and forced convection until the water absorbs sufficient heat for vaporization. By regulation of the water quantity, the degree of heat absorption can be controlled and a specified final steam temperature maintained. The linear positioning of the plug regulates water flow to the sprayhead of the DVG/AF. The main body diameter controls the flow of water, via radially drilled orifices, in the guide cage. A cross sectional drawing of the DVG/AF appears in figure 2. The DVG/AF desuperheater utilizes the proven, spring-loaded AF (Anti-Flash) nozzle to provide a uniform hollow cone spray pattern over a wide range of flow conditions (see figure 3). The water is injected through holes drilled at a compound angle to induce spin as the AF nozzle plug is opened with increasing water pressure. The design of the AF nozzle is such that water flows only after sufficient W / IL Figure 2. Detail of DVG/AF Desuperheater backpressure is available to provide a good spray pattern. The full opening of the AF nozzle is limited by a travel stop to keep the spring within its proper working range and to maintain the water film thickness at the necessary thickness for proper atomization. 2

3 Instruction Manual DVG/AF Desuperheater Table 2. T" Dimensions D T (1) Nominal Pipe Size, Inches NPS BODY STEM SPRING > mm PLUG NUT PIN WATER INJECTION HOLES 1. For the NPS 6 mounting flange, add 70 mm (2.75 inches) to the T" dimension. A7191 / IL Installation Figure 3. AF Nozzle Cross Section Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal injury. Personal injury or equipment damage caused by sudden release of pressure may result if the desuperheater is installed where service conditions could exceed the limits of the pressure class noted on the nameplate. To avoid such injury or damage, provide a relief valve for over pressure protection as required by government or accepted industry codes and good engineering practices. Check with your process or safety engineer for any additional measures that must be taken to protect against process media. If installing into an existing application, also refer to the at the beginning of the Maintenance section in this instruction manual. When ordered, the desuperheater configuration and construction materials were selected to meet particular pressure, temperature, pressure drop, and fluid conditions. Do not apply any other conditions to the desuperheater without first contacting your Emerson Process Management sales office. 1. Insert the DVG/AF desuperheater into the flanged pipe stud on the steam pipe (see table 2 and figure 4 for the proper T" length dimension). Bolt the unit to the pipe stud flange in accordance with standard piping practice. 2. Clean and flush out the cooling water line before connecting to the desuperheater. Use only clean sources of cooling water. Use of clean water decreases wear to the valve trim and prevents clogging of desuperheater orifices by solid particles. CAUTION Use only clean sources of cooling water. Emerson Process Management recommends installation of a strainer and isolating valve on the waterline leading to the desuperheater. Failure to use clean sources of cooling water and failure to install a strainer and isolating valve on the waterline may result in clogging of the desuperheater by solid particles, thus hampering temperature control of the steam. 3. A straight run of pipe is required downstream of the desuperheater to ensure complete vaporization of cooling water. Consult the desuperheater certified drawing for the required distance of straight pipe. 3

4 DVG/AF Desuperheater Instruction Manual 4. Typically, a temperature sensor should be mounted at a minimum distance of 9.1 meters (30 feet) downstream of the desuperheater. This distance will vary depending on steam velocity and percentage of spraywater. Consult the installation drawing provided with the unit for this distance or call your Emerson Process Management sales office. 5. The steam line should have no branch lines between the desuperheater and the downstream temperature sensor. 6. A typical control loop is illustrated in figure 5. A temperature sensor (TE) measures changes in temperature and transmits a signal to a remote temperature-indicating controller or distributed control system (DCS). The output signal from the controller is sent to the positioner on the desuperheater. The positioner output signal is piped to the actuator, which strokes the stem/plug of the desuperheater. A rising stem opens the desuperheater to allow additional water flow. Personal injury could result from packing leakage. Valve packing was tightened prior to shipment; however it should be checked for possible loosening due to shipping and handling. Check with your process or safety engineer for any additional measures that must be taken to protect against process media. Maintenance Instructions Servicing Avoid personal injury or property damage from sudden release of process pressure or bursting of parts. Before performing any maintenance operations: НAlways wear protective gloves, clothing, and eyewear when performing any maintenance operations to avoid personal injury. WATER FLANGE A7192 / IL Figure 4. DVG/AF T" Location MOUNTING FLANGE T HEIGHT NOMINAL PIPE SIZE НDisconnect any operating lines providing air pressure, electric power or a control signal to the actuator. Be sure the actuator cannot suddenly open or close the valve. НUse bypass valves or completely shut off the process to isolate the valve from process pressure. Relieve process pressure on both sides of the valve. Drain the process media from both sides of the valve. НVent the power actuator loading pressure and relieve any actuator spring precompression. НUse lock-out procedures to be sure that the above measures stay in effect while you work on the equipment. НThe valve packing box may contain process fluids that are pressurized, even when the valve has been removed from the pipeline. Process fluids may spray out under pressure when removing the packing hardware or packing rings, or when loosening the packing box pipe plug. НCheck with your process or safety engineer for any additional measures that must be taken to protect against process media. Shut off water and steam flow and vent all system pressure before removal of the desuperheater from the steam line. Disconnect the desuperheater from 4

5 Instruction Manual DVG/AF Desuperheater TC SPRAYWATER DVG/AF DESUPERHEATER WITH 667 ACTUATOR TE STEAMFLOW C0817/IL Figure 5. Typical DVG/AF Installation the flanged pipe stud and water flange. Withdraw the unit from the line. Temporarily connect the desuperheater to the air supply and verify proper action. To check for seat leakage, connect a water line to the unit and pressurize to service conditions. Disassembly Residual system pressure may be released during the following steps if the system was improperly isolated or vented. Use extreme care to prevent personal injury while loosening any fasteners in the pressure boundary. 1. Disconnect all field connections to the positioner and actuator. Remove the mounting and water flange bolting and remove the DVG/AF from the steam line. 2. Remove the actuator from the DVG/AF using the actuator manufacturer s removal instructions. Reference figure 6 for assistance in disassembly in the following steps. 3. Slowly loosen the bonnet nuts (key 36) approximately 1/16 inch in a uniform manner. 4. Break the bonnet (key 13) loose from the body (key 01). 5. After ensuring that the system is depressurized remove the bonnet nuts (key 36) and washers (key 35). 6. Remove the bonnet (key 13) from the body (key 01) taking care to avoid damage to the stem (key 17). 7. Remove the plug/stem assembly (keys 8, 17 and 18), cage guide (key 15) and seat (key14) for inspection. 8. Examine the removed parts for unusual wear and replace if necessary. 9. Remove and discard the seat gasket (key 30), bonnet gasket (key 31) and stem packing (key 24). 10. Remove the spray nozzle(s) (key 9) by unscrewing them from the nozzle holder after removing the anti-rotation tab(s). 5

6 DVG/AF Desuperheater Instruction Manual Stem packing is leaking Problem Stem packing is leaking after tightening stem packing nuts Actuator cannot open desuperheater Actuator cannot open desuperheater Actuator action is sticky" Actuator action is sticky" Actuator action is sticky" Temperature is below setpoint Temperature is below setpoint Temperature is below setpoint Temperature is below setpoint Water in steam line Water in steam line when steam line isolated Water in steam line when steam line isolated Bonnet gasket is leaking 11. Inspect the spray nozzles. The nozzles should be completely closed with no evidence of foreign debris or uneven action when opened and closed. If this is not the case and the nozzle(s) cannot be disassembled for cleaning; the nozzle(s) must be replaced to correct the problem. 12. Flush the desuperheater to remove any debris. Clean all gasket and part mating surfaces. Assembly 1. Reassemble the unit with new gaskets and packing following a reverse sequence of the disassembly. Lubricate all sliding surfaces and the bonnet studs and washers with a quality high temperature lubricant. The nozzle anti-rotation tabs can be replaced with any similar sized SA182-F22 (2-1/4 Cr--1 Mo) material or 9018 weld rod if required. Take care to avoid overheating the nozzle or getting weld spatter on the nozzle opening surface. Table 3. Troubleshooting Guide Tighten stem packing nuts Corrective Action Repack and replace worn parts as needed Check actuator calibration. Check for over-tightening of the packing nuts Check for alignment between actuator and DVG/AF Check positioner calibration Replace plug, cage, stem guide and/or packing follower Check water source availability and pressure Check nozzle(s) for plugging Make sure that steam saturation pressure is not above setpoint Check to ensure full actuator stroke is reached Check for proper orientation of nozzle in steam flow Check temperature control loop reset Check nozzle for fouling/poor spray pattern clean/replace Check temperature sensor location relocate per guidelines. Check for proper orientation of nozzle in steam flow Check that steam traps are functioning properly Check for proper desuperheater actuator installation Replace desuperheater seat and plug assembly Inspect body/bonnet mating surfaces, replace bonnet gasket. Ensure bonnet bolts are properly torqued. 3. Reinstall the packing ring, a new packing set, packing follower, flange and nuts. 4. Mount the actuator. When mounting the actuator it is critical to ensure that the stroke is set to ensure that proper seating load is available. Follow the guidelines set forth by the manufacturer in setting up the actuator. In general, position the plug on the seat, move the actuator to full open position, close the actuator for the length of the DVG/AF stroke and then connect actuator and DVG/AF stems. If more complete information is required, consult the actuator documentation. 5. Tighten the packing nuts as required. Torquing values are shown in table 5. Recheck the stem packing for leakage after the system is returned to service and retighten the packing nuts if required. Troubleshooting 2. Tighten the bonnet bolts in a multi-step uniform cross pattern. It is recommended that the bonnet bolt torquing be carried out in a minimum of four torque levels until the final torque is achieved. Torquing values are shown in table 4. The following guide (table 3) is intended as a basic first line troubleshooting guide. Contact your Emerson Process Management sales office for assistance if you are unable to resolve your field operation problem. 6

7 Instruction Manual DVG/AF Parts Ordering Each desuperheater assembly is assigned a serial number which can be found on the mounting flange of the desuperheater. Refer to the serial number when contacting your Emerson Process Management sales office for technical assistance. When ordering numbers for each part required, the key numbers on figure 6 can be used to help in part identification. DVG/AF Desuperheater Table 4. Recommended Bonnet Bolt Torque Recommended Bolt Size, Inch Threads per Inch Bolt Torque, Lbf ft (1) 5/ / Torques for studs with heavy hex nuts. Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Process Management should not, under any circumstances, be used in any Fisher valve, because they will void your warranty, might adversely affect the performance of the valve, and could cause personal injury and property damage. Note Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use and maintenance of any product. Responsibility for the selection, use, and maintenance of any product remains with the purchaser and end-user. Parts List Key НН1 НН2 НН3 НН4 НН5 НН7 НН8* НН9* Description Valve Body Valve Body Pipe Water Flange Water Pipe Valve Body Flange Nozzle Mount Plug Spray Nozzle Key Stem Diameter, Inch 1/2 3/4 Table 5. Recommended Packing Nut Torque Description Pressure Rating Н13 Bonnet Н14* Seat Н15* Cage Guide Н17* Stem Н18* Stem Pin Н23 Gland Ring Н24* Packing Set Н25 Gland Follower Н26 Gland Flange Н27 Gland Stud Н28 Gland Nut Н30* Seat Gasket Н31* Bonnet Gasket Н34 Bonnet Stud Н35 Bonnet Stud Washer Н36 Bonnet Stud Nut Maximum Torque, Lbf ft Minimum Torque, Lbf ft CL CL CL CL CL CL CL CL CL CL CL CL *Recommended spare parts 7

8 DVG/AF Desuperheater Instruction Manual B2603 / IL Figure 6. DVG/AF Assembly Fisher is a mark owned by Fisher Controls International LLC, a member of the Emerson Process Management business division of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use and maintenance of any product. Responsibility for the selection, use and maintenance of any product remains with the purchaser and end-user. Emerson Process Management Marshalltown, Iowa USA Sorocaba, Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore Singapore Fisher 8 Controls International LLC 1990, 2008; All Rights Reserved Printed in USA

Fisher DMA, DMA/AF, and DMA/AF HTC Mechanically Atomized Desuperheaters

Fisher DMA, DMA/AF, and DMA/AF HTC Mechanically Atomized Desuperheaters Instruction Manual DMA Desuperheater Fisher DMA, DMA/AF, and DMA/AF HTC Mechanically Atomized Desuperheaters Contents Introduction... 2 Scope of Manual... 2 Description... 2 Specifications... 2 Principle

More information

Fisher DFA Variable Geometry Desuperheater

Fisher DFA Variable Geometry Desuperheater Instruction Manual DFA Desuperheater Fisher DFA Variable Geometry Desuperheater Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 3 Principle of Operation... 3 Installation...

More information

Fisher RSS Lined Globe Valve

Fisher RSS Lined Globe Valve Instruction Manual D0990 November 009 RSS Valve Fisher RSS Lined Globe Valve Contents Introduction............................... Scope of Manual.......................... Description...............................

More information

WARNING. Mounting Instructions D103998X012 June DVC6200/DVC2000 Digital Valve Controller Linear Actuator Side Mount

WARNING. Mounting Instructions D103998X012 June DVC6200/DVC2000 Digital Valve Controller Linear Actuator Side Mount Mounting Instructions Use these instructions to mount a FIELDVUE DVC6200/DVC2000 to a Linear Side Mount Actuator WARNING Avoid personal injury or property damage from sudden release of process pressure

More information

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...

More information

Fisher RSS Lined Globe Valve

Fisher RSS Lined Globe Valve Instruction Manual D0990 RSS Valve July 07 Fisher RSS Lined Globe Valve Contents Introduction... Scope of Manual... Description... Educational Services... Specifications... Installation... Maintenance...

More information

Fisher 1B and 1BR Constant Pressure Pump Governor Actuators

Fisher 1B and 1BR Constant Pressure Pump Governor Actuators Instruction Manual 1B Actuator Fisher 1B and 1BR Constant Pressure Pump Governor Actuators Figure 1. Fisher 1B Actuator on Direct Acting easy e Valve W2232 1 Introduction Scope of Manual This instruction

More information

Fisher TBX Hydro Plug Fixture

Fisher TBX Hydro Plug Fixture Instruction Manual TBX Hydro-Plug Fixture Fisher TBX Hydro Plug Fixture Contents Introduction... 1 Scope of Manual... 1 Description... 2 Educational Services... 2 Principle of Operation... 2 Maintenance...

More information

Fisher 656 Diaphragm Actuator

Fisher 656 Diaphragm Actuator Instruction Manual 656 Actuator Fisher 656 Diaphragm Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 1 Principle of Operation... 2 Specifications... 2 Maximum Pressure Limitations...

More information

Fisher 2052 Diaphragm Rotary Actuator

Fisher 2052 Diaphragm Rotary Actuator Instruction Manual 2052 Actuator Fisher 2052 Diaphragm Rotary Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 4 Installation... 4 Actuator Mounting and Changing

More information

Fisher DFA Variable Geometry Desuperheater

Fisher DFA Variable Geometry Desuperheater DFA Desuperheater Product Bulletin Fisher DFA Variable Geometry Desuperheater The Fisher DFA (Desuperheater with Flexible Architecture) can be used in many applications to efficiently control the spraywater

More information

Fisher CVX Hydro Plug Fixture

Fisher CVX Hydro Plug Fixture Instruction Manual CVX Hydro-Plug Fixture Fisher CVX Hydro Plug Fixture Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 2 Principle of Operation... 2 Maintenance...

More information

WARNING. Mounting Instructions D103996X012 May DVC6200/DVC2000 Digital Valve Controller on Linear Actuator

WARNING. Mounting Instructions D103996X012 May DVC6200/DVC2000 Digital Valve Controller on Linear Actuator Use these instructions to mount a FIELDVUE to a. WARNING Avoid personal injury or property damage from sudden release of process pressure or bursting of parts. Before performing any maintenance operations:

More information

Baumann Mikroseal Control Valve

Baumann Mikroseal Control Valve Instruction Manual 81000 Valve Baumann 81000 Mikroseal Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 3 Installation... 3 Air Piping... 4 Flow Direction...

More information

Fisher 3024C Diaphragm Actuator

Fisher 3024C Diaphragm Actuator Instruction Manual 3024C Actuator Fisher 3024C Diaphragm Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 3 Installation... 5 Mounting the Actuator on the Valve...

More information

Fisher 644 and 645 Differential Pressure Pump Governors

Fisher 644 and 645 Differential Pressure Pump Governors Instruction Manual 644 and 645 Pump Governors Fisher 644 and 645 Differential Pressure Pump Governors Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services...

More information

Baumann 24000F Wafer Control Valve

Baumann 24000F Wafer Control Valve Instruction Manual 24000F Valves Baumann 24000F Wafer Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Installation... 3 Air Piping... 3 Disassembly...

More information

M Series Manual Handwheel Gear Actuator

M Series Manual Handwheel Gear Actuator Instruction Manual D500237X0 M Series Actuator M Series Manual Handwheel Gear Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 1 Installation... 3 Operation...

More information

Baumann Sanitary Angle Control Valve

Baumann Sanitary Angle Control Valve Baumann 83000 Sanitary Angle Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Educational Services... 2 Maintenance... 3 Installation... 3 Air Piping... 4 Flow Direction...

More information

Baumann Little Scotty Bronze Control Valve

Baumann Little Scotty Bronze Control Valve Instruction Manual 24000 Valve Baumann 24000 Little Scotty Bronze Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Installation... 3 Air Piping...

More information

Baumann Sanitary Diaphragm Angle and Inline Control Valve

Baumann Sanitary Diaphragm Angle and Inline Control Valve Instruction Manual 84000 Valve Baumann 84000 Sanitary Diaphragm Angle and Inline Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Flow Direction...

More information

M Series Manual Handwheel Gear Actuator

M Series Manual Handwheel Gear Actuator Instruction Manual M Series Actuator M Series Manual Handwheel Gear Actuator Contents Introduction............................... 1 Scope of Manual......................... 1 Description..............................

More information

Type 644 and 645 Differential Pressure Pump Governors

Type 644 and 645 Differential Pressure Pump Governors Instruction Manual 644 and 645 Pump Governors Type 644 and 645 Differential Pressure Pump Governors Introduction Scope of Manual This instruction manual provides information on installation, adjustment,

More information

Baumann Sanitary Control Valve

Baumann Sanitary Control Valve Instruction Manual 89000 Valve Baumann 89000 Sanitary Control Valve Contents Introduction... 2 Scope of Manual... 2 Educational Services... 2 Safety Precautions... 3 Maintenance... 4 Installation... 4

More information

Baumann Way Control Valve

Baumann Way Control Valve Instruction Manual 24003 Valve Baumann 24003 3-Way Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Educational Services... 3 Maintenance... 3 Installation... 3 Air

More information

Fisher D2T FloPro Control Valve

Fisher D2T FloPro Control Valve Instruction Manual D2T FloPro Valve Fisher D2T FloPro Control Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 2 Specifications... 3 Installation... 3 Setting

More information

WARNING. Mounting Instructions D103778X012 June 2013

WARNING. Mounting Instructions D103778X012 June 2013 Mounting Instructions D08X0 June 0 Use these instructions to mount a Fisher FIELDVUE DVC00 digital valve controller mounting kit for Universal (side mounting), sliding stem applications. WARNING Avoid

More information

Fisher ENVIRO SEAL Packing System for Rotary Valves

Fisher ENVIRO SEAL Packing System for Rotary Valves D0X0 July 07 Fisher ENVIRO SEAL Packing System for Rotary Valves Contents Introduction... Scope of Manual... Valve/Actuator Shaft Coupler... Description... Installation... Removing the Actuator... Installing

More information

Fisher 685 Piston Actuator

Fisher 685 Piston Actuator Instruction Manual 685 Piston Actuator Fisher 685 Piston Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services... 3 Principle of Operation...

More information

Type 1089 Valve Valve

Type 1089 Valve Valve Instruction Manual 1089 Valve Type 1089 Valve Contents Introduction............................... 1 Scope of manual......................... 1 Description.............................. 2 Specifications............................

More information

Fisher V270 Full-Bore Ball Control Valve

Fisher V270 Full-Bore Ball Control Valve Instruction Manual V270 Valve Fisher V270 Full-Bore Ball Control Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services... 3 Installation... 3 Maintenance...

More information

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions Instruction Manual D103356X012 24000C Control Valve Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions CONTENTS Introduction...1 Scope...1 Safety Precautions...1 Maintenance...2 Flow

More information

Baumann Sanitary Diaphragm Angle & In-Line Control Valve Instructions

Baumann Sanitary Diaphragm Angle & In-Line Control Valve Instructions Instruction Manual D103370X012 84000 Control Valve Baumann 84000 Sanitary Diaphragm Angle & In-Line Control Valve Instructions CONTENTS Introduction...1 Scope...1 Safety P recautions...1 Maintenance...2

More information

Fisher SS-263 Volume Booster

Fisher SS-263 Volume Booster Instruction Manual SS-263 Volume Booster Fisher SS-263 Volume Booster Contents Figure 1. Fisher SS-263 Volume Booster Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 2 Specifications...

More information

Fisher D and DA Valves

Fisher D and DA Valves Instruction Manual Fisher D and DA Valves Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services... 2 Ceramic Trim... 3 Installation... 3 Maintenance...

More information

Fisher TBX Steam Conditioning Valve

Fisher TBX Steam Conditioning Valve TBX Valve Product Bulletin Fisher TBX Steam Conditioning Valve The Fisher TBX Steam Conditioning Valve is designed to handle the most severe applications in today's cycling power plants as well as provide

More information

Fisher V250 Ball Valve

Fisher V250 Ball Valve Instruction Manual Fisher V250 Ball Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Installation... 3 Maintenance... 6 Replacing the Follower Shaft Seal... 6 Replacing the Drive

More information

Fisherr V150S Slurry Vee-Ball Control Valve NPS 3 through 12

Fisherr V150S Slurry Vee-Ball Control Valve NPS 3 through 12 Instruction Manual V150S Slurry Vee-Ball Valve Fisherr V150S Slurry Vee-Ball Control Valve through 12 Contents Introduction... 1 Scope of Manual... 1 Specification table... 2 Description... 2 Installation...

More information

Fisher CHP Control Valve

Fisher CHP Control Valve Instruction Manual D103463X012 CHP Valve Fisher CHP Control Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 1 Installation... 2 Maintenance... 3 Packing Maintenance...

More information

Fisher CAV4 Control Valve

Fisher CAV4 Control Valve Product Bulletin D10197X012 Fisher CAV Control Valve CAV Valve The Fisher CAV control valve (figure 1) with Cavitrol IV trim is designed specifically for liquid applications, such as boiler feedwater recirculation,

More information

Fisher 249 Cageless Displacer Sensors

Fisher 249 Cageless Displacer Sensors Instruction Manual 249 Cageless Sensors Fisher 249 Cageless Displacer Sensors Contents Introduction... 1 Scope of Manual... 1 Description... 1 Type Number Description... 2 Educational Services... 3 Maintenance...

More information

Fisher DSV High Performance Digester Switching Valve

Fisher DSV High Performance Digester Switching Valve Instruction Manual D101871X012 DSV Valve Fisher DSV High Performance Digester Switching Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 1 Installation... 3 Maintenance...

More information

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Valve Instructions

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Valve Instructions Instruction Manual D103360X012 24000CVF/SVF Control Valve Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Valve Instructions CONTENTS Introduction...1 Scope of Manual...1 Safety Precautions...1-2

More information

Fisher D4 Control Valve Assembly

Fisher D4 Control Valve Assembly Fisher D4 Control Valve Assembly Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services... 2 Installation... 4 Spring Adjustment... 5 Maintenance... 6

More information

Baumann Pneumatic Actuators

Baumann Pneumatic Actuators Instruction Manual Baumann Pneumatic Actuators Baumann Pneumatic Actuators Contents Introduction... 1 Scope of Manual... 1 Design Notes... 2 Installation... 2 Attaching an Air-to-Retract (ATR) Actuator

More information

Baumann Corrosion Resistant Control Valve

Baumann Corrosion Resistant Control Valve Product Bulletin D103337X012 Baumann 26000 Corrosion Resistant Control Valve The Baumann 26000 (figures 1 and 2) is a unique corrosion resistant control valve featuring a flangeless wafer valve body and

More information

Fisher 657NS Diaphragm Actuators Size 40, 45, 70, and 80

Fisher 657NS Diaphragm Actuators Size 40, 45, 70, and 80 Instruction Manual 657NS Actuator Fisher 657NS Diaphragm Actuators Size 40, 45, 70, and 80 Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 3 Educational Services... 3

More information

Fisher 480 Series Yokeless Piston Actuators

Fisher 480 Series Yokeless Piston Actuators Instruction Manual 480 Series Actuators Fisher 480 Series Yokeless Piston Actuators Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 1 Educational Services... 4 Actuator

More information

Fisher 249 Caged Displacer Sensors

Fisher 249 Caged Displacer Sensors Instruction Manual 249 Caged Sensors Fisher 249 Caged Displacer Sensors Contents Introduction... 1 Scope of Manual... 1... 2 Type Number... 3 Educational Services... 4 Maintenance... 4 Cleaning the Cage...

More information

Fisher EZ-Overtravel (EZ-OVT) Valve Trim

Fisher EZ-Overtravel (EZ-OVT) Valve Trim D103041X012 Fisher EZ-Overtravel (EZ-OVT) Valve Trim Fisher EZ-OVT valve trim is a dual seat valve trim, designed to maintain long term tight shutoff in on-off services that contain particulates in the

More information

Fisher POSI-SEAL A81 Rotary Valve (Obsolete Product)

Fisher POSI-SEAL A81 Rotary Valve (Obsolete Product) Obsolete Product A81 Valve October 2015 Fisher POSI-SEAL A81 Rotary Valve (Obsolete Product) Obsolete products may not be manufactured again in any Emerson Process Management location under any conditions.

More information

Fisher VBL Volume Booster

Fisher VBL Volume Booster Instruction Manual VBL Volume Booster Fisher VBL Volume Booster Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services... 2 Installation... 4 Mounting...

More information

Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions

Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions Product Bulletin D103308X012 DVC6000 Digital Valve Controllers Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions Digital Valve Controller Configuration Mounting Figure Page DVC6010 DVC6010 SIS

More information

Fisher CAV4 Control Valve

Fisher CAV4 Control Valve CAV Valve Product Bulletin Fisher CAV Control Valve The Fisher CAV control valve with Cavitrol IV trim is designed specifically for liquid applications, such as boiler feedwater recirculation, where pressure

More information

Fisher 377 Trip Valve

Fisher 377 Trip Valve Instruction Manual Fisher 377 Trip Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 3 Educational Services... 3 Installation... 4 Supply Pressure Requirements...

More information

Fisher 685SE and 685SR Piston Actuator

Fisher 685SE and 685SR Piston Actuator Instruction Manual 685SE/685SR Piston Actuator Fisher 685SE and 685SR Piston Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Principle of Operation... 3 Installation...

More information

Baumann Flexsleev Sanitary Control Valve

Baumann Flexsleev Sanitary Control Valve 87000 Valve Product Bulletin Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve is excellent for throttling high purity liquid or gaseous media commonly found in the food and

More information

Fisher L2e Electric Level Controller

Fisher L2e Electric Level Controller Instruction Manual L2e Controller Fisher L2e Electric Level Controller Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Educational Services... 2 Installation... 4 Attaching

More information

Fisher Vee-Ball V150 and V300 NPS 14 through 24x20 Rotary Control Valves

Fisher Vee-Ball V150 and V300 NPS 14 through 24x20 Rotary Control Valves Instruction Manual V150 and V300 Valves Fisher Vee-Ball V150 and V300 NPS 14 through 24x20 Rotary Control Valves Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational

More information

Fisher 2625 and 2625NS Volume Boosters

Fisher 2625 and 2625NS Volume Boosters Instruction Manual 2625 and 2625NS Volume Booster Fisher 2625 and 2625NS Volume Boosters Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 3 Educational Services... 3 Installation...

More information

Fisher 667NS Diaphragm Actuators Size 40, 45, 70, and 80

Fisher 667NS Diaphragm Actuators Size 40, 45, 70, and 80 Instruction Manual 667NS Actuator Fisher 667NS Diaphragm Actuators Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 3 Educational Services... 3 Maximum Pressure Limitations...

More information

Fisher 657 Diaphragm Actuator Sizes and 87

Fisher 657 Diaphragm Actuator Sizes and 87 Instruction Manual 657 Actuator (30-70 and 87) Fisher 657 Diaphragm Actuator Sizes 30 70 and 87 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Mounting

More information

Fisher 377 Trip Valve

Fisher 377 Trip Valve 377 Trip Valve Product Bulletin Fisher 377 Trip Valve Fisher 377 pressure sensing trip valves are for control applications where a specific valve/actuator action is required when supply pressure falls

More information

Zero Point Calibration HART Communicating Fisher FIELDVUE DVC6200 Digital Valve Controllers

Zero Point Calibration HART Communicating Fisher FIELDVUE DVC6200 Digital Valve Controllers Zero Point Calibration HART Communicating Fisher FIELDVUE s The Zero Point Calibration procedure allows you replace an existing DVC6200 digital valve controller without performing a travel calibration.

More information

Fisher 249VS Cageless Displacer Sensor

Fisher 249VS Cageless Displacer Sensor Instruction Manual 249VS Sensor Fisher 249VS Cageless Displacer Sensor Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 3 Installation... 3 Mounting the Sensor on

More information

Design D and DA Control Valves

Design D and DA Control Valves Product Bulletin Design D and DA Control Valves D and DA Valves Design D and DA single-port, high-pressure valves (figure ) are widely used in oil and gas production industries. These valves are especially

More information

Design CP Control Valve with ENVIRO-SEAL Bellows Seal Bonnet

Design CP Control Valve with ENVIRO-SEAL Bellows Seal Bonnet Instruction Manual Form 5410 November 1998 Design CP/ENVIRO-SEAL Bellows Seal Design CP Control Valve with ENVIRO-SEAL Bellows Seal Bonnet Contents Introduction.............................. 1 Scope of

More information

Fisher CCV-N Fuel Gas Control Valve

Fisher CCV-N Fuel Gas Control Valve CCV-N Valve Product Bulletin Fisher CCV-N Fuel Gas Control Valve Fisher CCV-N fuel gas control valves are used in gas turbines which meter the fuel gas to the combustion chamber of the turbine and provide

More information

Baumann Series Flexsleev Control Valve Instructions

Baumann Series Flexsleev Control Valve Instructions Instruction Baumann 86000 Series Instructions Baumann 86000 Series Flexsleev Control Valve Instructions Contents Introduction...1 Scope...1 Safety Precautions...1 Maintenance...2 Installation...3 Air Piping...3

More information

Fisher D4 Control Valve Assembly

Fisher D4 Control Valve Assembly Product Bulletin D103039X012 Fisher D4 Control Valve Assembly D4 Valve The Fisher D4 control valve is a compact, rugged globe valve designed primarily for high-pressure throttling applications. This valve

More information

Design EUD, EUT-2, EWD, and EWT-2 Valves

Design EUD, EUT-2, EWD, and EWT-2 Valves Instruction Manual EUD, EUT-2, EWD, and EWT-2 Valves Design EUD, EUT-2, EWD, and EWT-2 Valves Contents Introduction............................... 1 Scope of Manual.......................... 1 Description...............................

More information

Fisher Vee-Ball V150 and V300 NPS 14 through 20 Rotary Control Valves

Fisher Vee-Ball V150 and V300 NPS 14 through 20 Rotary Control Valves Instruction Manual V150 and V300 Valves Fisher Vee-Ball V150 and V300 through 20 Rotary Control Valves Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Installation...

More information

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations Instruction Manual 1061 F & G Actuator Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...

More information

Baumann 24000S Stainless Steel Control Valve

Baumann 24000S Stainless Steel Control Valve 24000S Valve Product Bulletin Baumann 24000S Stainless Steel Control Valve The Baumann 24000S versatile, pneumatic, control valve may be used for the control of pressure, temperature, level, and flow.

More information

Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators

Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators Instruction Manual 1051 and 1052 H & J Actuators Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...

More information

Fisher CVX Steam Conditioning Valve

Fisher CVX Steam Conditioning Valve Instruction Manual CVX Valve Fisher CVX Steam Conditioning Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 3 Principle of Operation... 3 Installation... 4

More information

Fisherr D4 Control Valve Assembly

Fisherr D4 Control Valve Assembly Instruction Manual D4 Valve Fisherr D4 Control Valve Assembly Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Installation... 4 Spring Adjustment... 5 Maintenance...

More information

Fisher 8580 Rotary Valve

Fisher 8580 Rotary Valve Instruction Manual Fisher 8580 Rotary Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Installation... 4 Maintenance... 8 Packing Maintenance... 8 Replacing the

More information

Fisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations

Fisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations Instruction Manual 1061 H & J Actuator Fisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...

More information

Fisher CAV4 Control Valve

Fisher CAV4 Control Valve Fisher CAV4 Control Valve CAV4 (globe) CAV4 (NPS 2) CAV4 (angle) CAV4 (NPS 2 through 6) CAV4 Series Valves The Fisher CAV4 control valve with Cavitrol IV trim is designed specifically for liquid applications,

More information

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators Instruction Manual Form 5116 Types 1808 and 1808A July 2010 Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators! Warning Failure to follow these instructions or to properly install

More information

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Control Valves

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Control Valves 24000CVF and 24000SVF Valves Product Bulletin Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Control Valves The Baumann 24000CVF and 24000SVF line of control valves can be utilized for the

More information

Connectors for Diagnostic Testing with the FlowScanner Valve Diagnostic System

Connectors for Diagnostic Testing with the FlowScanner Valve Diagnostic System Instruction Manual Connectors for FlowScanner System Connectors for Diagnostic Testing with the FlowScanner Valve Diagnostic System Contents Introduction............................... 1 Scope of Manual.........................

More information

Fisher POSI-SEAL A31A Cryogenic High Performance Butterfly Valve

Fisher POSI-SEAL A31A Cryogenic High Performance Butterfly Valve Product Bulletin D500230X012 A31A Cryogenic Valve Fisher POSI-SEAL A31A Cryogenic High Performance Butterfly Valve Description The Fisher A31A Cryogenic High Performance Butterfly Valve (HPBV) is designed

More information

Fisher FB Control Valve

Fisher FB Control Valve Fisher FB Control Valve Fisher FB fabricated angle valves are used with compressible fluids on special applications requiring maximum noise attenuation capability and high capacity. Typical applications

More information

Fisherr easy -et Cryogenic Sliding -Stem Control Valves

Fisherr easy -et Cryogenic Sliding -Stem Control Valves Product Bulletin D102189X012 easy--e Cryogenic Valves Fisherr easy -et Cryogenic Sliding -Stem Control Valves Fisher easy--e cryogenic valves are globe--style, single--port, valves featuring stainless

More information

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions DVC600 Digital Valve Controller D103543X01 Product Bulletin 6.1:DVC600(S1) December 011 Fisher FIELDVUE DVC600 Digital Valve Controller / Magnet Assembly Dimensions Digital Valve Controller Configuration

More information

Fisher 461 Increased Outlet Angle Sweep-Flo Valve

Fisher 461 Increased Outlet Angle Sweep-Flo Valve 461 Valve Product Bulletin Fisher 461 Increased Outlet Angle Sweep-Flo Valve The Fisher 461 Sweep-Flo valve is a self-cleaning, increased outlet, angle valve that is typically used in the chemical and

More information

Fisher EU and EW Valves NPS 12 through 24 x 20

Fisher EU and EW Valves NPS 12 through 24 x 20 Product Bulletin D102004X012 Fisher EU and EW Valves NPS 12 through 24 x 20 EU Valve The Fisher NPS 12 through 24 20 CL150 through CL600 EUT-2, EWT-2, EUD, EWD, EUT, and EWT general-purpose valves (figures

More information

L3 Pneumatic Level Controller

L3 Pneumatic Level Controller Product Bulletin D103194X012 L3 Controller L3 Pneumatic Level Controller The L3 pneumatic level controller (see figure 1) is designed to sense liquid level or interface level in a vessel, and produce a

More information

Fisher DSV High Performance Digester Switching Valve (Obsolete Product)

Fisher DSV High Performance Digester Switching Valve (Obsolete Product) Obsolete Product DSV Valve October 2015 Fisher DSV High Performance Digester Switching Valve (Obsolete Product) Obsolete products may not be manufactured again in any Emerson Process Management location

More information

Model DF269 Control Valve

Model DF269 Control Valve Figure 1 DF269 Control Valve TABLE OF CONTENTS Introduction 2 Fail Open Actuator Disassembly 6 General 2 Body and Packing Reassembly 7 Scope 2 Fail Closed Actuator Resassembly 8 Specifications 3 Fail Open

More information

Fisher TBX Steam Conditioning Valve

Fisher TBX Steam Conditioning Valve Instruction Manual TBX Valve Fisher TBX Steam Conditioning Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Educational Services... 2 Installation... 4 Maintenance... 7 Servicing...

More information

Fisher FB Control Valve

Fisher FB Control Valve Instruction Manual Fisher FB Control Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services... 2 Installation... 3 Lifting Valve Assembly... 6 Maintenance...

More information

Fisher L3 Pneumatic Level Controller

Fisher L3 Pneumatic Level Controller L3 Controller Product Bulletin Fisher L3 Pneumatic Level Controller The Fisher L3 pneumatic level controller is designed to sense liquid level or interface level in a vessel, and produce a standard pneumatic

More information

Type 289P Pilot-Operated Relief Valve

Type 289P Pilot-Operated Relief Valve Instruction Manual D102680X012 Type 289P July 2017 Type 289P Pilot-Operated Relief Valve Figure 1. 1 NPT Type 289P Pilot-Operated Relief Valve Figure 2. 2 NPT Type 289P Pilot-Operated Relief Valve Introduction

More information

Fisher CV500 Rotary Control Valve

Fisher CV500 Rotary Control Valve Product Bulletin D101606012 Fisher CV500 Rotary Control Valve CV500 Valve The Fisher CV500 Cam Vee Ball control valve combines the rangeability of the cammed-segmented V-notched ball, with the inherent

More information

Fisher Sliding-Stem Valve Selection Guide

Fisher Sliding-Stem Valve Selection Guide Sliding-Stem Valve Selection Guide Product Bulletin Fisher Sliding-Stem Valve Selection Guide W8861 W7957-2 X0165 GX easy-e Typical Fisher Sliding-Stem Control Valves TBX STEAM CONDITIONING VALVE A broad

More information

Fisher 2506 and 2516 Receiver Controllers

Fisher 2506 and 2516 Receiver Controllers 2506/2516 Receiver Controllers Product Bulletin Fisher 2506 and 2516 Receiver Controllers The 2506 receiver controller takes the input from a pneumatic transmitter, matches it against the adjustable set

More information

Fisher V150S Slurry Vee-Ball Control Valve

Fisher V150S Slurry Vee-Ball Control Valve Slurry Vee-Ball Valve Product Bulletin Fisherr V150S Slurry Vee-Ball Control Valve The Fisher V150S Slurry Vee-Ball valve mates with CL150 raised face flanges. Rugged construction, highly wear-resistant

More information