Powder Feed Center. Customer Product Manual Part A03

Size: px
Start display at page:

Download "Powder Feed Center. Customer Product Manual Part A03"

Transcription

1 Powder Feed Center Customer Product Manual Issued 1/09 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) or contact your local Nordson representative. This document is subject to change without notice. Check for the latest version. NORDSON CORPORATION AMHERST, OHIO USA

2 Contact Us Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General information about Nordson can be found on the Internet using the following address: Address all correspondence to: Nordson Corporation Attn: Customer Service 555 Jackson Street Amherst, OH Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice. Trademarks Nordson and the Nordson logo are registered trademarks of Nordson Corporation. Tivar is a registered trademark of Poly Hi Solidur, Inc. Vibrasonic is a trademark of Russell Finex Limited Corporation.

3 Table of Contents Safety Introduction Qualified Personnel Intended Use Regulations and Approvals Personal Safety Fire Safety Grounding Action in the Event of a Malfunction Disposal Description Introduction Components Operator Interface Theory of Operation Powder Fluidization and Transfer Air Filtration Purge Cycle Sure Max Powder Transfer System Operation 2-7 Normal Operation Color Change Operation Initial Setup Introduction User Access Levels Feed Center Configuration Menu Spray System Configuration Menu Typical Operating Settings Operating Air Pressures Cartridge Filter Pulse Valve Timing Settings Level Sensor Programming Operation One Button Level Sensor Probe Programming Operational Faults (Red LED Flashing) Locking and Unlocking Adjustment Two Button Level Sensor Probe Programming 3-11 LED Functions for Operation Empty (no powder) Adjustment Full Adjustment Locking and Unlocking Adjustment Operational Faults Operation Introduction Operator Interface Menus Main Menu Auto Menu Manual Functions Setup and Special Functions Daily Startup Powder Feed Source Installation Powder Box Installation Fluidizing Hopper Installation Shutdown

4 Color Change Introduction Types of Color Changes Performing a Color Change Color Change Control Menu Menu Navigation Color Change Menu Functions Quick Color Change System Color Change Process Changing the Sure Max Filter Element Removal Installation Washing the Sure Max Filter Element Conventional System Color Change Process Maintenance Daily Maintenance Emptying the Waste Hopper Periodic Maintenance Troubleshooting Powder Supply Problems Purge Cycle Problems Bottom of Stroke Sensor and Stop Bolt Realignment Sieve Problems Filter Section Problems Repair Introduction Cartridge Filter Replacement Removing the Cartridge Filter Installing the Cartridge Filter Final Filter Replacement Pulse Valve Replacement Waste Hopper Fluidizing Plate Replacement Vibratory Table Isolator Mount Replacement Parts Introduction Using the Illustrated Parts List Powder Feed Center Assembly Sieve Assembly Sure Max Powder Transfer System Sure Max System Assembly Sure Max Receiver and Filter Filter Containers Lance Arm Assembly Vibratory Table and Purge Assembly Fan Housing Assembly Blowdown Housing Assembly Cartridge Filter Housing Assembly Fluid Bed Assembly

5 Options Introduction Fluidizing Hopper Installation Fluidizing Plate Replacement Fluidizing Hopper Parts Vibrasonic Sieve Screen Vibrasonic System Components Installation Vibrasonic Transducer and Sieve Screen Installation Control Box and Cable Installation Operation Troubleshooting Fault Conditions Causes and Corrective Actions VIBRASONICS/POWER Indicator Troubleshooting Vibrasonic System Parts

6 4

7 Safety 1-1 Section 1 Safety Introduction Read and follow these safety instructions. Task- and equipment-specific warnings, cautions, and instructions are included in equipment documentation where appropriate. Make sure all equipment documentation, including these instructions, is accessible to all persons operating or servicing equipment. Qualified Personnel Equipment owners are responsible for making sure that Nordson equipment is installed, operated, and serviced by qualified personnel. Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks. Intended Use Use of Nordson equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property. Some examples of unintended use of equipment include using incompatible materials making unauthorized modifications removing or bypassing safety guards or interlocks using incompatible or damaged parts using unapproved auxiliary equipment operating equipment in excess of maximum ratings Regulations and Approvals Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson equipment will be voided if instructions for installation, operation, and service are not followed.

8 1-2 Safety All phases of equipment installation must comply with all federal, state, and local codes. Personal Safety Fire Safety To prevent injury follow these instructions. Do not operate or service equipment unless you are qualified. Do not operate equipment unless safety guards, doors, or covers are intact and automatic interlocks are operating properly. Do not bypass or disarm any safety devices. Keep clear of moving equipment. Before adjusting or servicing any moving equipment, shut off the power supply and wait until the equipment comes to a complete stop. Lock out power and secure the equipment to prevent unexpected movement. Relieve (bleed off) hydraulic and pneumatic pressure before adjusting or servicing pressurized systems or components. Disconnect, lock out, and tag switches before servicing electrical equipment. Obtain and read Material Safety Data Sheets (MSDS) for all materials used. Follow the manufacturer s instructions for safe handling and use of materials, and use recommended personal protection devices. To prevent injury, be aware of less-obvious dangers in the workplace that often cannot be completely eliminated, such as hot surfaces, sharp edges, energized electrical circuits, and moving parts that cannot be enclosed or otherwise guarded for practical reasons. To avoid a fire or explosion, follow these instructions. Do not smoke, weld, grind, or use open flames where flammable materials are being used or stored. Provide adequate ventilation to prevent dangerous concentrations of volatile materials or vapors. Refer to local codes or your material MSDS for guidance. Do not disconnect live electrical circuits while working with flammable materials. Shut off power at a disconnect switch first to prevent sparking.

9 Safety 1-3 Know where emergency stop buttons, shutoff valves, and fire extinguishers are located. If a fire starts in a spray booth, immediately shut off the spray system and exhaust fans. Clean, maintain, test, and repair equipment according to the instructions in your equipment documentation. Use only replacement parts that are designed for use with original equipment. Contact your Nordson representative for parts information and advice. Grounding WARNING: Operating faulty electrostatic equipment is hazardous and can cause electrocution, fire, or explosion. Make resistance checks part of your periodic maintenance program. If you receive even a slight electrical shock or notice static sparking or arcing, shut down all electrical or electrostatic equipment immediately. Do not restart the equipment until the problem has been identified and corrected. All work conducted inside the spray booth or within 1 m (3 ft) of booth openings is considered within a Class 2, Division 1 or 2 Hazardous location and must comply with NFPA 33, NFPA 70 (NEC articles 500, 502, and 516), and NFPA 77, latest conditions. All electrically conductive objects in the spray areas shall be electrically connected to ground with a resistance of not more than 1 megohm as measured with an instrument that applies at least 500 volts to the circuit being evaluated. Equipment to be grounded includes, but is not limited to, the floor of the spray area, operator platforms, hoppers, photoeye supports, and blow-off nozzles. Personnel working in the spray area must be grounded. There is a possible ignition potential from the charged human body. Personnel standing on a painted surface, such as an operator platform, or wearing non-conductive shoes, are not grounded. Personnel must wear shoes with conductive soles or use a ground strap to maintain a connection to ground when working with or around electrostatic equipment. Operators must maintain skin-to-handle contact between their hand and the gun handle to prevent shocks while operating manual electrostatic spray guns. If gloves must be worn, cut away the palm or fingers, wear electrically conductive gloves, or wear a grounding strap connected to the gun handle or other true earth ground. Shut off electrostatic power supplies and ground gun electrodes before making adjustments or cleaning powder spray guns. Connect all disconnected equipment, ground cables, and wires after servicing equipment.

10 1-4 Safety Action in the Event of a Malfunction If a system or any equipment in a system malfunctions, shut off the system immediately and perform the following steps: Disconnect and lock out electrical power. Close pneumatic shutoff valves and relieve pressures. Identify the reason for the malfunction and correct it before restarting the equipment. Disposal Dispose of equipment and materials used in operation and servicing according to local codes.

11 Description 2-1 Section 2 Description Introduction The Nordson powder feed center delivers powder to up to 27 powder spray guns, while simultaneously receiving and conditioning reclaimed powder and introducing it back into the virgin powder source. The powder feed center efficiently reclaims powder and helps a powder coating system achieve fast, efficient color changes. Refer to Table 2-1. The powder feed center may be used with two types of powder coating systems: System Type Quick Color Change Conventional Table 2-1 Compatible Powder Coating Systems Description These systems are specially equipped to quickly perform color changes. Quick color change systems include the following Nordson product lines: Colormax Sure Clean These systems use conventional cyclone or cartridge technology. Conventional color change systems include the following Nordson product lines: Cyclo-Kinetic Excel Horizon

12 2-2 Description Components Refer to Table 2-2 and Figure 2-1 for a description of the feed center standard components. Table 2-2 Powder Feed Center Components Item Component Description 1 Fan/Filter Section Filters the air in the powder feed center enclosure before returning it to the spray room. 2 Enclosure Area where powder is distributed to and returned from the powder coating system. 3 Control Panel Houses the feed center operator interface and electrical and pneumatic controls; refer to Operator Interface for information about the operator interface. 4 Sure Max Powder Transfer System NOTE: The Sure Max powder transfer system is used only with the Colormax and Sure Clean powder coating systems. Your system may not have the Sure Max powder transfer system. In quick color change systems, draws powder from cyclones and drops powder into sieve. Refer to Sure Max Powder Transfer System Operation in this section for more information. 5 Lance Assembly Consists of a vertical slide assembly and one, two, or three pump block assemblies. Each pump block assembly consists of a pickup tube manifold and up to nine inline powder pumps. A pneumatic cylinder raises and lowers the lance assemblies in and out of the feed source and onto the purge manifold. The pumps are operated by the spray gun control system. While feeding from a standard box of powder, the lance assembly fluidizes the powder. The operator adjusts the fluidizing air pressure using a needle valve located on the lance assembly. 6 Sieve Breaks up clumps of reclaimed powder and separates usable reclaimed powder from waste. NOTE: An optional, higher throughput Vibrasonic sieve screen is available. Refer to Vibrasonic Sieve Screen in the Options section for parts and installation information. Continued...

13 Description 2-3 Item Component Description 7 Feed Source Stores the powder supply for the spray guns. The source may be either a standard box of powder or an optional fluidizing hopper. NOTE: Optional fluidizing hopper is shown. Refer to the Options section for more information. 8 Vibratory Table Vibrates to prevent cavitation when feeding powder from a standard box of powder. NOTE: The vibratory table only vibrates for a short time while the optional fluidizing hopper is being used. 9 Purge Manifold Pulses compressed air through the pickup tubes, pumps, powder feed hoses, and spray guns to blow out all loose powder. Consists of one manifold block for each lance assembly. Each manifold block is equipped with up to nine open ports to match the number of pumps and spray guns in the system Figure 2-1 Powder Feed Center Components

14 2-4 Description Operator Interface The control panel houses a PLC that controls the powder feed center s operations. The operator can adjust and start or stop the automated functions using the touch screen operator interface located in the control panel. Refer to the Operation section for more information about the operator interface. NOTE: In quick color change systems, the PLC and operator interface also control other booth functions. Refer to your quick color change system manual for more information about the operator interface. Theory of Operation The following paragraphs explain how the powder feed center operates. Powder Fluidization and Transfer See Figure 2-2. A feed source (5) is placed directly on the vibratory table (6). Powder in the feed source is fluidized and the lance assembly (4) lowers in one of the following ways: Box of Powder: The vibratory table vibrates to maintain an even distribution of powder in the box. The lance assembly fluidizes the powder in the box. When all feed center functions are set to AUTO, the lance assembly lowers until its level sensor senses the powder in the box, and continues to lower as the powder level falls. When the level sensor senses that the lance assembly has lowered below a set limit, the sensor activates either a low-powder alarm or automatic bulk feed. Fluidizing Hopper (Optional): Compressed air forced through a porous fluidizing plate in the bottom of the hopper fluidizes the powder in the hopper. When all feed center functions are set to AUTO, the lance assembly lowers into the hopper until it reaches a set position. The lance assembly stays at the set position. When the level sensor senses that the powder level has fallen below a set limit (above the lance inlet), the sensor activates either a low-powder alarm or automatic bulk feed. Air flowing through the powder pumps (3) draws the fluidized powder up the lance assembly and out the powder feed hoses to the spray guns. Standard powder feed centers have two sets of powder feed hoses: one for use with light-colored powders, and one for use with dark-colored powders. Having two separate sets of powder feed hoses minimizes the possibility of cross-contamination of powder after a color change.

15 Description 2-5 In applications that use special powders (such as metallics or textures), a separate set of hoses can be added. The feed center can accommodate up to four sets of hoses: Standard, light-color powders Standard, dark-color powders Special, light-color powders Special, dark-color powders When a set of hoses is not being used, it is stored offline in the hose locker on the side of the feed center Figure 2-2 Powder Feed Center Operation 1. Purge manifold 2. Sieve 3. Powder pumps Note: Optional fluidizing hopper shown. 4. Lance assembly 5. Feed source 6. Vibratory table

16 2-6 Description Air Filtration See Figure 2-3. The exhaust fan (1) draws airborne powder through the cartridge filters (4), where the powder collects on the filter media. The pulse valves (3) send periodic pulses of air through the cartridge filters, blowing the powder off the filter media. The powder then falls into the waste hopper (5), which holds the waste powder until the operator empties it using the feed center s transfer pump. Any powder that remains in the air that passes through the cartridge filters is collected on the final filters (2) before the air returns to the spray room Figure 2-3 Powder Feed Center Air Filtration 1. Exhaust fan 2. Final filters 3. Pulse valves 4. Cartridge filters 5. Waste hopper

17 Description 2-7 Purge Cycle See Figure 2-2. The operator starts a purge cycle either when changing colors or shutting down the system. When the purge cycle starts, the spray guns turn off and the lance assembly raises up out of the feed source. The operator blows powder off the lance assembly, then removes the feed source from the vibratory table. The operator lowers the lance assembly until the pickup tubes contact the purge manifold (1). The purge manifold sends timed pulses of air through the pickup tubes, powder pumps, powder feed hoses, and spray guns. NOTE: Depending on how the feed center is configured, the purge cycle purges each pump block assembly separately, or all pump block assemblies at the same time. Sure Max Powder Transfer System Operation NOTE: In powder coating systems that do not have the Sure Max powder transfer system, oversprayed powder collects in either a surge hopper at the bottom of the cyclones or the booth collector module. A transfer pump pumps the powder back to the powder feed center. Refer to the following paragraphs for the Sure Max powder transfer system s process during normal and color change operations.

18 2-8 Description Normal Operation See Figure 2-4. During normal operation, reclaimed powder collects in the transfer pan (11) at the bottom of the cyclones. The scrap port on the transfer pan is plugged with the scrap cap (9), and both reclaim plugs (3) are disconnected. The vacuum amplifier (1) draws the reclaimed powder out of the transfer pan and through the reclaim conveyor line (8). The powder collects in the reclaim receiver (5), which filters the powder from the air before it gets to the vacuum amplifier. The reclaim receiver s discharge door (6) periodically opens, dropping the reclaimed powder into the sieve (7). The sieve separates contaminates from the reclaimed powder before dropping the powder back into the feed source. 2 1 Reclaimed Powder Vacuum Figure 2-4 Sure Max Powder Transfer System: Normal Operation 1. Vacuum amplifier 2. Vacuum diverter handle 3. Reclaim plug 4. Reclaim couplings 5. Reclaim receiver 6. Discharge door 7. Sieve 8. Reclaim conveyor line 9. Scrap cap 10. Scrap conveyor line 11. Transfer pan 12. Scrap receiver

19 Description 2-9 Color Change Operation See Figure 2-5. At the beginning of the color change process, the discharge door (6) remains open. Pulses of air are forced through the filter in the reclaim receiver (5), blowing loose powder off the filter. At the end of the color change process, the operator disconnects the reclaim couplings (4) attaching the reclaim conveyor line (8); cleans and plugs (3) the reclaim conveyor line; removes the scrap cap (9) and installs the scrap conveyor line (10). The operator then turns the vacuum diverter handle (2) counterclockwise to cause oversprayed powder to be drawn out of the transfer pan (11) and into the scrap receiver (12). Spraying 0.5 kg (one lb) of overspray to waste seasons the ducts and cyclones, allowing for efficient powder reclaim during normal operation. After 0.5 kg (one lb) of overspray has been collected in the scrap receiver, the operator disconnects the scrap conveyor line; installs the scrap cap; uncaps and connects the reclaim conveyor line; and turns the diverter handle clockwise to return the system to normal operation (reclaim mode). 2 1 Reclaimed Powder Vacuum Figure 2-5 Sure Max Powder Transfer System: Color Change Operation 1. Vacuum amplifier 2. Vacuum diverter handle 3. Reclaim plug 4. Reclaim couplings 5. Reclaim receiver 6. Discharge door 7. Sieve 8. Reclaim conveyor line 9. Scrap cap 10. Scrap conveyor line 11. Transfer pan 12. Scrap receiver

20 2-10 Description

21 Initial Setup 3-1 Section 3 Initial Setup WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction This section explains how to set up the powder feed center to suit your application requirements. The following topics are covered in this section: Topic User Access Levels Feed Center Configuration Menu Spray System Configuration Menu Typical Operating Settings Level Sensor Programming Description Logging in to the feed center s operator interface using one of three access levels Setting up the operator interface to recognize the optional hardware that is included with your feed center Setting up the operator interface to recognize the optional hardware that is included in the powder coating system Setting the recommended air pressure and cartridge filter pulse timing values for the feed center Programming the level sensor probe to cause the lance assembly to raise or lower to the appropriate level in the powder feed source These procedures need to be completed only when you start up the powder feed center for the first time. After the initial configuration is completed and the system is operating, you may also access the configuration menus to change operating parameters.

22 3-2 Initial Setup User Access Levels There are three user access levels. Not all users have access to adjust all functions of the powder feed center. The user access level can be changed by touching the Log-On button in the Special Functions area of the Main Menu or on either of the configuration screens. Refer to Table 3-1 for a list of the three user access levels and their passwords. The default user access level is Operator. Table 3-1 User Access Levels User Access Level Password Operator 0 Lead Operator 108 Supervisor 1597 Feed Center Configuration Menu See Screen 3-1. The Feed Center Configuration menu appears the first time that the powder feed center is powered up. This menu allows you to identify the components that are used in your powder feed center. All configuration settings on the menu are YES/NO selections. Touch a button to change the current selection from NO to YES. Touch the button again to change it back to NO. Refer to Table 3-2 for a description of the buttons on the menu. NOTE: To access the Feed Center Configuration menu from the Main Menu, touch the Special Functions button, then the System Config button. Screen 3-1 Feed Center Configuration Menu

23 Initial Setup 3-3 Sure Clean Spray System Colormax Spray System Sure Max System Table 3-2 Feed Center Configuration Menu Selection Description Note Select YES if the feed center is used with a Sure Clean system Select YES if the feed center is used with a Colormax system Select YES if the feed center is equipped with a Sure Max powder transfer system Gun Purge Valve #1 Select YES if purge valve #1 is used A Gun Purge Valve #2 Select YES if purge valve #2 is used A Gun Purge Valve #3 Select YES if purge valve #3 is used A Sieve Vibrator Select YES if the feed center is equipped with a vibratory B sieve motor (feed center does not have a feed chute vibrator) Vibrasonic Sieve Screen Select YES if the feed center is equipped with the Vibrasonic sieve screen system Feed Chute Vibrator Select YES if the feed center is equipped with a feed B chute vibrator (feed center does not have a vibratory sieve motor) Four Filter Pulse Valves Select YES if there are four cartridge filters (the standard number is three) Configuration Completed Select YES if the configuration process has been completed The Spray System Configuration menu will appear when you touch this button if either Sure Clean System or Colormax System is set to YES The Special Functions menu will appear when you touch this button if either Sure Clean System or Colormax System is set to NO Special Functions Opens the Special Functions menu C Log-On Allows you to change to a different user access level Config System Opens the Spray System Configuration menu C NOTE A: Each gun purge valve can purge up to nine spray guns. Enable the appropriate number of gun purge valves based on how many spray guns are in your system. B: The powder feed center has either a sieve vibrator motor or a feed chute vibrator. C: This button is visible only if Configuration Completed is set to YES.

24 3-4 Initial Setup Spray System Configuration Menu See Screen 3-2. The Spray System Configuration menu allows you to identify the components that are used in your powder coating system. Screen 3-2 Spray System Configuration Menu

25 Initial Setup 3-5 All configuration buttons on the menu are YES/NO selections. Touch a button to change the current selection from NO to YES. Touch the button again to change it back to NO. Refer to Table 3-3 for a description of the buttons on the menu. Table 3-3 Spray System Configuration Menu Selection Description Note Remote Exhauster Panel Select YES if your system has a remote after filter and exhauster panel Oscillator #1 Select YES if your system has one or more vertical oscillators Oscillator #2 Select YES if your system has two vertical oscillators Automatic Gunmovers Booth Mover After Filter Rolls w/ Booth Configuration Completed Select YES if your system has one or more horizontal in/out positioners Select YES if your system is equipped with a roll-on/roll-off system Select YES if the after filter moves with the rest of the booth and Booth Mover is set to YES Select YES if you are finished making the selections on the Spray System Configuration menu Special Functions Opens the Special Functions menu B Log-On Allows you to change to a different user access level Previous Opens the Feed Center Configuration menu B NOTE A: These settings are only applicable to powder coating systems equipped with roll-on/roll-off systems. Leave all of these set to NO if your system does not have a roll-on/roll-off system. B: These buttons are visible only if Configuration Completed is set to YES. A A

26 3-6 Initial Setup Typical Operating Settings The settings listed here are approximate. You may need to adjust these settings to obtain the desired results. Operating Air Pressures Refer to Table 3-4 for a list of typical operating air pressures. These settings are average starting points. You may need to adjust these settings depending on your application. Table 3-4 Typical Operating Air Pressures Air Pressure Setting Input (Minimum) 6 bar (90 psi) Cartridge Filter Pulse 2.75 bar (40 psi) Waste Hopper Fluidizing 0.5 bar (8 psi) Fluidizing Hopper (Optional) 0.3 bar (5 psi) Waste Hopper Transfer Pump 2.75 bar (40 psi) Lance Assembly Raise 5.5 bar (80 psi) Lower 3 bar (45 psi) Cartridge Filter Pulse Valve Timing Settings Refer to Table 3-5 for typical pulse valve timing settings. These settings are average starting points. You may need to adjust the settings if the feed center s cartridge filters are not being pulsed sufficiently. NOTE: The pulse valves are typically set to PULSE-ON-DEMAND. Most systems are normally set to automatically pulse the cartridge filters when the differential pressure across the filters reaches approximately 3-in. wc, which is approximately 1-in. wc higher than the pressure drop at startup. The exact reading will depend on the life of the cartridge filters. Table 3-5 Typical Pulse Valve Timer Board Settings Timer Setting Filter Pulse On Duration 0.07 seconds Filter Pulse Off Duration 90 seconds

27 Initial Setup 3-7 Level Sensor Programming Operation The level sensor probe signals the lance assembly to raise or lower to the appropriate level in the powder feed source. Follow these procedures to program the level sensor probe to recognize the level of powder in the feed source. There are two different kinds of sensor probes that are identified by the number of programming buttons on the probe. The level sensor probe has two operating states: empty powder and full. The function of these operating states is dependent on whether the feed source is a box of powder or the optional fluidizing hopper. Operating State Box of Powder Fluidizing Hopper Empty (no powder) Full The lance assembly lowers until the probe senses powder, then stops. When the probe no longer senses powder, the lance assembly lowers until it senses powder in the full range. When the probe senses powder in the full range, the lance assembly stops. When the lance assembly is at its lowest allowable level and the powder level falls below the full range, the probe activates either a low powder alarm or automatic bulk feed. If the probe senses powder above the full range, the lance assembly raises to maintain the optimum level for fluidization by the lance assembly. When the probe does not sense powder in the full range, it activates either a low powder alarm or automatic bulk feed. When the probe senses powder the low powder alarm and bulk feed are turned off.

28 3-8 Initial Setup One Button Level Sensor Probe Programming YELLOW RED GREEN PROGRAMMING BUTTON Figure 3-1 Programming the Level Sensor Probe LED Functions for Operation LED Color Status Meaning Green Lit continuously Ready for operation (power is on) Yellow Lit continuously Output has switched (powder is detected; full condition) Yellow and Flashing quickly Short circuit of the switching output Red Red Lit temporarily Normal function check; level sensor probe is approaching the full state Lit continuously Level sensor probe is dirty or out of adjustment.

29 Initial Setup 3-9 Empty (no powder) Adjustment NOTE: Completing the Empty Powder Adjustment overwrites the values set in the Full Adjustment. If you complete a Empty Powder Adjustment, be sure to complete a Full Adjustment. The level sensor probe is operational after the empty powder adjustment, but completing the full adjustment allows the level sensor probe to operate at its fullest potential. 1. Make sure that the level sensor probe is in the fully down position. Refer to Powder Box Installation in the Operation section. 2. Put a box or hopper of powder on the vibratory table and turn on fluidizing air to the lance assembly. If using a hopper, allow the powder in the box to thoroughly fluidize. 3. From the Main Menu, touch the Auto Menu button to open the Auto Menu. On the Auto Menu, touch the LANCE UP button. Raise the lance assembly so that the bottom of the level sensor is at least 25 mm (1 in.) away from the top level of the fluidized powder. 4. See Figure 3-1. Press the programming button until the green LED flashes slowly. When the green LED stops flashing and the yellow LED turns off, the Empty Adjustment is complete. NOTE: If the programming button remains pressed after the green LED flashes slowly, the green light will eventually start to flash quickly, signaling the programming for the Full Adjustment instead of the Empty Adjustment. To correct the error in programming, repeat the steps from the beginning for programming the Empty Adjustment. Full Adjustment NOTE: You may complete the Full Adjustment as often as you like without overwriting the Empty Powder Adjustment value. 1. Place a box or hopper of powder on the vibratory table. If using a hopper, allow the powder to thoroughly fluidize. 2. From the Auto Menu, touch the LANCE DOWN button. Lower the lance assembly until the fluidized powder covers at least 25 mm (1 in.) of the tip of the level sensor probe. 3. See Figure 3-1. Press the programming button until the green LED flashes quickly. The green LED flashes slowly at first, then after five seconds it flashes quickly. When both the green and the yellow LEDs are lit continuously, the Full Adjustment is complete.

30 3-10 Initial Setup Operational Faults (Red LED Flashing) If either the empty or full adjustment cannot be completed, the probe s red LED flashes quickly. Task Clearing a Fault Correcting Possible Causes for the Fault Procedure Clear the fault by either pressing the programming button once, or turning off power to the feed center, then turning it back on again. Check for and correct any of these possible causes for the fault: The signal difference between the empty powder and full states is too small (the level between empty powder and full was not great enough). The empty powder adjustment was completed while the level sensor probe was in the powder, or the full adjustment was completed while the level sensor probe was out of the powder. During the empty powder adjustment, the distance between the level sensor probe and the powder was too short. Locking Unlocking Task Locking and Unlocking Adjustment The level sensor probe can be locked to protect it from unauthorized adjustment. Use these guidelines to lock or unlock the level sensor probe. NOTE: The level sensor probe is shipped from the factory in the unlocked state. Procedure Press the programming button for 10 seconds. The green LED will flash slowly for five seconds, then it will flash quickly. When the green LED turns off, the level sensor probe is locked. When the green LED turns back on continuously, the level sensor probe is ready for operation. Press the programming button for 10 seconds. After 10 seconds, all LEDs turn off, indicating that the level sensor probe is unlocked.

31 Initial Setup 3-11 Two Button Level Sensor Probe Programming When you program the level sensor probe, the powder feed center exhaust fan must be on and the Lance/Purge Mode must be set to Manual. NOTE: Your system may have two level sensor probes. Perform the following procedures for both probes. LED Ring OUT OFF Programming Button OUT ON Programming Button Figure 3-2 Programming the Two Button Level Sensor Probe LED Functions for Operation LED Color Status Meaning Green On Material not detected Yellow On Material detected

32 3-12 Initial Setup Empty (no powder) Adjustment 1. Put a box or hopper of powder on the vibratory table. 2. Make sure that the level sensor probe is in the fully down position. Refer to Powder Box Installation in the Operation section. 3. Put a box or hopper of powder on the vibratory table and turn on fluidizing air to the lance assembly. If using a hopper, allow the powder in the box to thoroughly fluidize. 4. From the Auto Menu, touch the LANCE DOWN button. Lower the lance assembly until the powder covers at least 25 mm (1 in.) of the tip of the level sensor probe. 5. From the Auto Menu, touch the LANCE UP button. Raise the lance assembly so that the bottom of the level sensor is at least 25 mm (1 in.) away from the top level of the powder. 6. See Figure 3-2 Press the OUT OFF programming button until the LED ring slowly flashes yellow. 7. Release the button and the yellow light will go off. The empty adjustment is complete. Full Adjustment 1. Place a box or hopper of powder on the vibratory table. 2. From the Auto Menu, touch the LANCE DOWN button. Lower the lance assembly until the powder covers at least 25 mm (1 in.) of the tip of the level sensor probe and LED ring should light up yellow. 3. See Figure 3-2. Press the OUT ON programming button until the yellow light from the LED ring goes from flashing slowly to flashing quickly. 4. Release the button and the LED ring lights yellow continuously. The full adjustment is complete.

33 Initial Setup 3-13 Locking Unlocking Task Locking and Unlocking Adjustment The level sensor probe can be locked to protect it from unauthorized adjustment. Use these guidelines to lock or unlock the level sensor probe. NOTE: The level sensor probe is shipped from the factory in the unlocked state. Procedure Simultaneously press the two programming buttons for at 10 seconds in the operating mode. Once the LED ring light changes its status for a brief moment, release the buttons, and the lock is complete. Simultaneously press the two programming buttons for at 10 seconds in the operating mode. Once the LED ring light changes its status for a brief moment, release the buttons, and the unlock is complete. Operational Faults If the sensor deviates from normal operation, use the following steps to return to normal operation. Task Return to Normal Operation Procedure Check for and correct any of these possible causes for incorrect operation: The difference between the empty and full states is not great enough. The empty adjustment was completed while the level sensor probe was in the powder, or the full adjustment was completed while the level sensor probe was out of the powder. During the empty adjustment, the distance between the level sensor probe and the powder was too short.

34 3-14 Initial Setup

35 Operation 4-1 Section 4 Operation WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction NOTE: If you are using the powder feed center with a quick color change system, refer to your quick color change system manual for procedures for operating the powder feed center with the system. The PLC in the powder feed center control panel controls most of the automatic processes in a typical system. Your Nordson application engineer typically programs and configures the PLC to suit your application requirements. NOTE: Your feed center may not have all of the functions that are identified in this section.

36 4-2 Operation Operator Interface Menus The following paragraphs explain the functions of the basic menus that appear on the feed center s operator interface. The menus shown are typical. Your feed center s menus may appear slightly different. Main Menu See Screen 4-1. The Main Menu is the first menu that appears when you start up the powder feed center for normal operation. Touching the buttons at the bottom of the menu allow you to access the feed center controls. The Auto, Manual, Setup, and Special Functions buttons appear at the bottom of every screen. Touching the Auto button causes the Auto Menu to appear. Touching the Manual, Setup, and Special Functions buttons causes a row of buttons to appear directly above the existing buttons. NOTE: Refer to Manual Functions in this section for more information about the Manual functions. Contact your Nordson representative for information about the Setup and Special Functions buttons. Screen 4-1 Main Menu

37 Operation 4-3 Auto Menu The Auto Menu allows the operator to control the automated functions of the powder feed center. Refer to Table 4-1 for a description of the typical functions of the buttons on the Auto Menu. See Screen 4-2. Screen 4-2 Auto Menu Alarm Button Table 4-1 Auto Menu Functions Function Appears in the upper right-hand corner of the menu when an alarm is present. Opens the Alarm Display menu. SYSTEM START/STOP LANCE UP/DOWN GO TO COLOR CHANGE MENU FINISH COLOR CHANGE NOTE: Refer to your quick color change system manual s Troubleshooting section for more information about the Alarm Display menu. Starts and stops all normal powder feed center functions. Raises and lowers the lance assembly (when the Lance/Purge Mode is set to MANUAL). Opens the Color Change menu. NOTE: Refer to the Color Change section for more information about the Color Change menu. Returns the system to normal operation after the color change process is complete. Continued...

38 4-4 Operation Auto Menu (contd) Button Select Box Select Hopper Enable Reclaim Spray Enable Virgin Powder Enable Vibrasonic Lance/Purge Mode Blowoff Mode Main DISABLE SURE MAX SYSTEM Table 4-1 Auto Menu Functions (contd) Function When using a box of powder as a feed source, the vibratory table turns on; lance assembly fluidizing air turns on; and lance assembly lowers as the powder level lowers. (Bulk powder can be added automatically when the lance assembly reaches the box of powder limit switch position.) The button displays BOX Selected when it is touched. NOTE: The low powder alarm will be activated when the lance assembly stays at the box of powder limit switch position for an extended period of time. When using the optional fluidizing hopper as a feed source, the vibratory table turns off; lance assembly fluidizing air turns off; and lance assembly maintains fixed position and activates bulk feed as the powder level lowers. The button displays HOPPER Selected when it is touched. NOTE: The low powder alarm will be activated if the level of powder remains below the lance s powder sensor for an extended period of time. Enables system to collect and reuse oversprayed powder. Allows powder from a bulk source to be automatically added to the feed source in the powder feed center. Starts the optional Vibrasonic system. Refer to Vibrasonic Sieve Screen in the Options section for more information. Switches between MANUAL and AUTO lance assembly/purge operating modes. Interrupts the automated purge process. Switches between MANUAL and AUTO gun blow-off operating modes. Interrupts the automated gun blow-off process. Opens the Main Menu. Stops the Sure Max powder transfer system.

39 Operation 4-5 Manual Functions Touch the Manual button on the Main Menu to display the manual function buttons. Following is a list of the manual function buttons. NOTE: Your system may have other manual functions. Refer to your powder coating system manual for information about functions not explained in this manual. fan motor (start/stop) waste pumps (start/stop) sieve (start/stop) collector filter pulsing (continuous/on-demand) lance assembly (raise/lower) purge process (start/stop) Setup and Special Functions The Setup and Special Functions buttons display buttons that can adjust advanced operating parameters and other functions. These functions are customized to your system and should only be adjusted under the supervision of your Nordson representative.

40 4-6 Operation Daily Startup Use the following procedures to start up the powder feed center on a daily basis. NOTE: These procedures assume that the powder coating system (including the feed center) has been cleaned and is in the online position. 1. Turn the powder feed center control panel disconnect switch to the on position. 2. Start up your powder coating system by performing the startup procedure in the powder coating system manual. 3. Touch the Auto button on the Main Menu to display the Auto Menu. 4. See Screen 4-3. Touch the SYSTEM START button. All of the motors in the system turn on. Screen 4-3 Auto Menu 5. Install the appropriate feed source. Refer to Powder Feed Source Installation for instructions on installing the feed source. NOTE: Make sure that the Lance/Purge Mode is set to AUTO. 6. Touch the Select Box or Select Hopper button to match the feed source installed. The button text will change to either BOX Selected or HOPPER Selected and the lance assembly will move to the position appropriate for the feed source. NOTE: If you touch either the BOX Selected or HOPPER Selected buttons, the lance will automatically raise to the fully up position.

41 Operation Adjust the fluidizing air pressure: Powder Box: Adjust the needle valve on the lance assembly. Fluidizing Hopper: Adjust the fluidizing air at the powder feed center s pneumatic panel. (Recommended setting: 0.3 bar (5 psi)) 8. Touch the following buttons (as applicable) to activate options for your feed center: Enable Reclaim Spray Enable Virgin Powder Enable Vibrasonic 9. Start spraying powder. Powder Feed Source Installation Use one of the following procedures to install a powder feed source into the powder feed center. Powder Box Installation 1. On the Auto Menu, set the Lance/Purge Mode to MANUAL. 2. See Figure 4-1. Touch the LANCE UP button to raise the lance assembly (5). 3. Loosen the thumb screw (1) and slide the level sensor probe (4) down until it stops against the top of the probe bracket (2). Tighten the thumb screw. 4. Open the box of powder and place it on the vibratory table. 5. Make sure that the box is centered under the lance assembly, then secure the box to the vibratory table using the box guides and clamping levers. 6. Set the Lance/Purge Mode to AUTO. When all feed center modes are set to AUTO, the lance assembly lowers as the powder level falls. When the level sensor senses that the lance assembly has lowered below the box limit, the sensor activates either a low-powder alarm or automatic bulk feed.

42 4-8 Operation Fluidizing Hopper Installation 1. On the Auto Menu, set the Lance/Purge Mode to MANUAL. 2. See Figure 4-1. Touch the LANCE UP button to raise the lance assembly (5). 3. Loosen the thumb screw (1). Slide the level sensor probe (4) up until the collar (3) stops against the bottom of the probe bracket (2), then tighten the thumb screw. 4. Remove the front box guide from the vibratory table and set it aside. 5. Place the hopper on the vibratory table. Make sure that the hopper is centered under the lance assembly, then remove the lid from the hopper. 6. Connect the fluidizing air tubing to the air fitting on the hopper. NOTE: Adjust the fluidizing air pressure at the feed center s pneumatic panel as necessary. 7. Set the Lance/Purge Mode to AUTO. When all feed center modes are set to AUTO, the lance assembly stays at a fixed position. When the level sensor senses that the powder level has fallen below the hopper limit, the sensor activates either a low-powder alarm or automatic bulk feed. 5 Hopper 1 Box Figure 4-1 Level Sensor Probe Adjustment 1. Thumb screw 2. Probe bracket 3. Collar 4. Level sensor probe 5. Lance assembly Note: Level sensor probe shown in the powder box (down) position.

43 Operation 4-9 Shutdown Use the following procedure to shut down the powder feed center. 1. Move the system offline, if applicable. 2. Clean the system by performing the color change process, but do not install a new powder source. Refer to the Color Change section for more information. NOTE: If you are shutting down the system for a short break in production, do not perform steps 3 or See Screen 4-3. From the Auto Menu, touch the SYSTEM STOP button. All of the motors in the system turn off. 4. If you will be shutting down the powder feed center for maintenance, repair, or an extended period of time, perform these steps: a. Press the SYSTEM STOP button on the system control panel. b. Turn the disconnect switch on the powder feed center control panel to the off position.

44 4-10 Operation

45 Color Change 5-1 Section 5 Color Change WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Introduction Use the following procedures to change colors in the powder feed center. Follow the procedures listed in your system and application equipment manuals to clean the booth canopy and powder application equipment. The operators start the automated tasks of the color change process by using the Color Change and Auto Menu screens. NOTE: Your powder coating system may not have all of the equipment or functions described in this section. Disregard any steps that refer to equipment or functions that are not present in your system. Types of Color Changes Refer to Table 5-1 for descriptions of the two types of color changes. Color Change Type Table 5-1 Types of Color Changes Description Similar Shade When changing from either a light powder to another light powder, or a dark powder to another dark powder. Different Shade When changing from either or a light powder to a dark powder, Different Powder Type a dark powder to a light powder, a standard powder to a special powder, or a special powder to a standard powder. NOTE: The time that it takes to perform a different shade/powder type color change will depend on how many spray guns are in your system.

46 5-2 Color Change Types of Color Changes (contd) Refer to Table 5-2. The powder feed center may be used with two types of powder coating systems. The powder feed center has a specific color change process for each type of system. System Type Quick Color Change Conventional Table 5-2 Compatible Powder Coating Systems Description These systems are specially equipped to quickly perform color changes. Quick color change systems include the following Nordson product lines: Colormax Sure Clean These systems use conventional cyclone or cartridge technology. Conventional color change systems include the following Nordson product lines: Cyclo-Kinetic Excel Horizon

Sure-Max Powder Transfer System

Sure-Max Powder Transfer System Sure-Max Powder Transfer System Customer Product Manual Issued 7/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local

More information

Prodigy HDLV Generation II Pump Panel

Prodigy HDLV Generation II Pump Panel Prodigy HDLV Generation II Pump Panel Customer Product Manual Issued 01/10 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change

More information

Prodigy HDLV Pump. Customer Product Manual Part A02

Prodigy HDLV Pump. Customer Product Manual Part A02 Prodigy HDLV Pump Customer Product Manual Issued 1/07 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

Prodigy HDLV Pump Manifold and Circuit Board

Prodigy HDLV Pump Manifold and Circuit Board Prodigy HDLV Pump Manifold and Circuit Board Customer Product Manual Issued 05/08 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is available

More information

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07 RediCoat by Nordson Hopper and VBF Dolly Systems Customer Product Manual Part 1082648A Issued 10/07 This document is subject to change without notice. Nordson Corporation Amherst, Ohio USA 2 Table of Contents

More information

Prodigy Powder Port Feed Center

Prodigy Powder Port Feed Center Prodigy Powder Port Feed Center Customer Product Manual Issued 2/ For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is subject to change without

More information

Encore HD Powder Spray System with Prodigy Pump Cabinet

Encore HD Powder Spray System with Prodigy Pump Cabinet Encore HD Powder Spray System with Prodigy Pump Cabinet Customer Product Manual Part 604979-06 Issued 05/8 For parts and technical support, call the Industrial Coating Systems Customer Support Center at

More information

Colormax Powder Coating System Color Change Process

Colormax Powder Coating System Color Change Process Nordson Corporation OPERATOR S CARD P/N 1015049B Colormax Powder Coating System Color Change Process Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions

More information

Econo-Coat Manual Powder Spray Gun

Econo-Coat Manual Powder Spray Gun Econo-Coat Manual Powder Spray Gun Customer Product Manual Issued 0/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local

More information

Encore HD Automatic System Standalone Pump Stand

Encore HD Automatic System Standalone Pump Stand Encore HD Automatic System Standalone Pump Stand Customer Product Manual Part 6 0 Issued /7 For parts and technical support, call the Finishing Customer Support Center at (00) 4-99. This document is subject

More information

Tribomatic II Extended Automatic Powder Spray Gun

Tribomatic II Extended Automatic Powder Spray Gun Tribomatic II Extended Automatic Powder Spray Gun Customer Product Manual Issued 7/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact

More information

Big Bag Unloader. Customer Product manual Part Number Issued 07/17

Big Bag Unloader. Customer Product manual Part Number Issued 07/17 Big Bag Unloader Customer Product manual Part Number 7580188-01 Issued 07/17 For parts ordering, call the Industrial Coating Systems EU Customer Support Center on 0080070017001 or contact your local Nordson

More information

Vantage Manual Powder Spray Gun

Vantage Manual Powder Spray Gun Vantage Manual Powder Spray Gun Customer Product Manual Issued 04/16 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change without

More information

Excel 3000 Series Powder Coating System

Excel 3000 Series Powder Coating System Excel 3000 Series Powder Coating System Customer Product Manual Part 1095480 02 Issued 1/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433 9319

More information

Tribomatic II Purgeable Automatic Powder Spray Gun

Tribomatic II Purgeable Automatic Powder Spray Gun Tribomatic II Purgeable Automatic Powder Spray Gun Customer Product Manual Issued 4/0 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 4-99 or contact

More information

ColorMax 2 Powder Coating System with Encore Feed Center

ColorMax 2 Powder Coating System with Encore Feed Center ColorMax 2 Powder Coating System with Encore Feed Center Customer Product Manual Issued 10/15 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319

More information

NVR-Series Vertical Reciprocators

NVR-Series Vertical Reciprocators NVR-Series Vertical Reciprocators Customer Product Manual Issued /6 For parts and technical support, call the Finishing Customer Support Center at (800) 4-99. This document is subject to change without

More information

Prodigy ColorMax Powder Coating System

Prodigy ColorMax Powder Coating System Prodigy ColorMax Powder Coating System Customer Product Manual Issued 6/09 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your

More information

902 Powder Coating Booth

902 Powder Coating Booth 902 Powder Coating Booth Customer Product Manual Part For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

Vantage Modular Gun Control System

Vantage Modular Gun Control System Vantage Modular Gun Control System Customer Product Manual Issued 04/5 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is available on the Internet

More information

Encore HD and XT Manual Powder Spray System Controller

Encore HD and XT Manual Powder Spray System Controller Encore HD and XT Manual Powder Spray System Controller Customer Product Manual Issued 04/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319

More information

Envirocoat Series Powder Coating System

Envirocoat Series Powder Coating System Envirocoat Series Powder Coating System Customer Product Manual Issued 2/11 For parts and technical support, contact your local Nordson representative This document is subject to change without notice.

More information

Versa-Spray IPS Manual Electrostatic Porcelain Enamel Powder Spray Gun

Versa-Spray IPS Manual Electrostatic Porcelain Enamel Powder Spray Gun Versa-Spray IPS Manual Electrostatic Porcelain Enamel Powder Spray Gun Customer Product Manual Issued 11/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center

More information

Sure Coat Individual Controllers

Sure Coat Individual Controllers Sure Coat Individual Controllers Customer Product Manual Issued 9/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local

More information

Spectrum HD Feed Center

Spectrum HD Feed Center Spectrum HD Feed Center Customer Product Manual Issued 09/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson

More information

Prodigy HDLV Pump Generation III, Pump Manifold and Circuit Board

Prodigy HDLV Pump Generation III, Pump Manifold and Circuit Board Prodigy HDLV Pump Generation III, Pump Manifold and Circuit Board Customer Product Manual Issued 3/6 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. Check

More information

Encore HD Pump. For parts and technical support, call the Finishing Customer Support Center at (800)

Encore HD Pump. For parts and technical support, call the Finishing Customer Support Center at (800) Encore HD Pump Customer Product Manual Issued 3/18 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. Check http://emanuals.nordson.com/finishing for the latest

More information

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B

Sure Coat Modular Gun Control System Part B: Pneumatic Modules. Customer Product Manual Part B Sure Coat Modular Gun Control System Part B: Pneumatic Modules Customer Product Manual Issued 4/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800)

More information

Auto-Flo Air-Assist Automatic Dispensing Valve

Auto-Flo Air-Assist Automatic Dispensing Valve Auto-Flo Air-Assist Automatic Dispensing Valve Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its

More information

Versa-Spray IPS Automatic Electrostatic Porcelain Enamel Powder Spray Gun

Versa-Spray IPS Automatic Electrostatic Porcelain Enamel Powder Spray Gun Versa-Spray IPS Automatic Electrostatic Porcelain Enamel Powder Spray Gun Customer Product Manual Issued 05/6 For parts and technical support, call the Industrial Coating Systems Customer Support Center

More information

2 8 CC Ejector Gun. Customer Product Manual Part

2 8 CC Ejector Gun. Customer Product Manual Part 2 8 CC Ejector Gun Customer Product Manual Issued 03/14 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B Sure Coat Modular Gun Control System Part D: Gun Purge Module Customer Product Manual Issued 4/0 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 4-919

More information

Rhino SD3/XD3 Air Motor

Rhino SD3/XD3 Air Motor Rhino SD3/XD3 Air Motor Customer Product Manual Issued 6/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson

More information

EcoLiner Compound Gun

EcoLiner Compound Gun EcoLiner Compound Gun Customer Product Manual Issued 3/06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

Versa-Spray II Automatic Powder Spray Gun

Versa-Spray II Automatic Powder Spray Gun Versa-Spray II Automatic Powder Spray Gun Customer Product Manual Issued 05/6 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your

More information

Mastic Gun. Customer Product Manual Part A. Issued 2/04 NORDSON CORPORATION AMHERST, OHIO USA

Mastic Gun. Customer Product Manual Part A. Issued 2/04 NORDSON CORPORATION AMHERST, OHIO USA Mastic Gun Customer Product Manual Issued 2/04 NORDSON CORPORTION MHERST, OHIO US Table of Contents Safety...................................... 1 Qualified Personnel........................ 1 Intended

More information

Ink-Dot Hydraulic System with Reservoir Manifold

Ink-Dot Hydraulic System with Reservoir Manifold Ink-Dot Hydraulic System with Reservoir Manifold Customer Product Manual Issued 7/10 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 This

More information

Auto-Flo Panel Reinforcement Automatic Dispensing Valve

Auto-Flo Panel Reinforcement Automatic Dispensing Valve Auto-Flo Panel Reinforcement Automatic Dispensing Valve Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries

More information

Prodigy Robot Gun. For parts and technical support, call the Finishing Customer Support Center at (800)

Prodigy Robot Gun. For parts and technical support, call the Finishing Customer Support Center at (800) Prodigy Robot Gun Customer Product Manual Issued 3/14 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change without notice. Check

More information

Sure Coat Manual Gun Control Unit

Sure Coat Manual Gun Control Unit Sure Coat Manual Gun Control Unit Customer Product Manual Issued 6/07 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your local

More information

Prodigy Automatic Powder Spray Guns

Prodigy Automatic Powder Spray Guns Prodigy Automatic Powder Spray Guns Customer Product Manual Part 1054075-09 Issued 8/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or

More information

Electrostatic Flux Coating System

Electrostatic Flux Coating System Electrostatic Flux Coating System Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. General

More information

Vantage Individual Powder Spray Gun Controller

Vantage Individual Powder Spray Gun Controller Vantage Individual Powder Spray Gun Controller Customer Product Manual Issued 04/15 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject

More information

Prodigy Generation II High-Capacity HDLV Powder Transfer Pump

Prodigy Generation II High-Capacity HDLV Powder Transfer Pump Prodigy Generation II High-Capacity HDLV Powder Transfer Pump Customer Product Manual Issued 0/0 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document

More information

Pro-Meter Gear Metering Pump

Pro-Meter Gear Metering Pump Pro-Meter Gear Metering Pump Customer Product Manual Part 0808E-0 Issued 4/6 NORDSON CORPORATION AMHERST, OHIO USA tents Table of Contents Safety... Qualified Personnel... Intended Use... Regulations and

More information

Rhino SD3/XD3 5-Gallon Follower Modules

Rhino SD3/XD3 5-Gallon Follower Modules Rhino SD3/XD3 5-Gallon Follower Modules Customer Product Manual Part 6033 03 Issued 6/8 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or

More information

Spectrum VT Feed Center

Spectrum VT Feed Center Spectrum VT Feed Center Customer Product Manual Issued 06/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson

More information

Versa-Spray II Automatic Powder Spray Gun

Versa-Spray II Automatic Powder Spray Gun Versa-Spray II Automatic Powder Spray Gun Customer Product Manual Issued /06 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-939 or contact your

More information

Econo-Coat Series II Powder Coating System

Econo-Coat Series II Powder Coating System Econo-Coat Series II Powder Coating System Customer Product Manual Issued 10/10 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to

More information

A16A Inside Stripe Gun

A16A Inside Stripe Gun A6A Inside Stripe Gun Customer Product Manual Issued 5/0 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is subject to change without notice.

More information

Encore HD Manual Powder Spray Gun

Encore HD Manual Powder Spray Gun Encore HD Manual Powder Spray Gun Customer Product Manual Issued 04/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local

More information

Prodigy Manual Powder Spray Guns

Prodigy Manual Powder Spray Guns Prodigy Manual Powder Spray Guns Customer Product Manual Issued 6/07 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local

More information

Universal Automatic Non-Conductive Fluid Regulator

Universal Automatic Non-Conductive Fluid Regulator Universal Automatic Non-Conductive Fluid Regulator Customer Product Manual Part 1017527 04 Issued 3/18 NORDSON CORPORATION AMHERST, OHIO USA Table of Contents tents Safety... 1 Qualified Personnel... 1

More information

High-Pressure Fluid Filters

High-Pressure Fluid Filters High-Pressure Fluid Filters Customer Product Manual Part 107971C02 NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products.

More information

Rhino SD2/XD2 Frames

Rhino SD2/XD2 Frames Rhino SD2/XD2 Frames Customer Product Manual 0308-0 Issued 03/8 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 33-939 or contact your local Nordson

More information

Lean Cell Powder Spray System

Lean Cell Powder Spray System Lean Cell Powder Spray System Customer Product Manual Issued 6/16 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson

More information

Spectrum VT Inline Powder Feed Pump

Spectrum VT Inline Powder Feed Pump Instruction Sheet P/N 160919 01 Spectrum VT Inline Powder Feed Pump WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other

More information

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206

Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206 Instruction Sheet 7-2013 Installation Instructions for Remote Mount HMI 211 Display Panel Kit A045J206 1 Introduction The information contained within is based on information available at the time of going

More information

Encore HD Manual Powder Spray System

Encore HD Manual Powder Spray System Encore HD Manual Powder Spray System Customer Product Manual Issued 04/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your

More information

ColorMax Powder Coating Booth Installation Guide

ColorMax Powder Coating Booth Installation Guide ColorMax Powder Coating Booth Installation Guide Customer Product Manual Issued /0 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is subject

More information

Encore Automatic Porcelain Enamel HD Powder Spray Gun

Encore Automatic Porcelain Enamel HD Powder Spray Gun Encore Automatic Porcelain Enamel HD Powder Spray Gun Customer Product Manual Issued 08/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319

More information

NRPS-100 Rotary Sieve

NRPS-100 Rotary Sieve NRPS-100 Rotary Sieve Customer Product Manual Part For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

Spectrum Powder Coating System

Spectrum Powder Coating System Spectrum Powder Coating System Customer Product Manual Part For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson

More information

Powder Bell. Customer Product Manual Part A NORDSON CORPORATION AMHERST, OHIO USA

Powder Bell. Customer Product Manual Part A NORDSON CORPORATION AMHERST, OHIO USA Powder Bell Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

Trilogy Air Spray and LVLP Automatic Spray Guns

Trilogy Air Spray and LVLP Automatic Spray Guns Trilogy Air Spray and LVLP Automatic Spray Guns Customer Product Manual Part 1601058-03 Issued 3/14 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800)

More information

Flow-Through-Felt Controller for Gravity Feed Applicators

Flow-Through-Felt Controller for Gravity Feed Applicators Flow-Through-Felt Controller for Gravity Feed Applicators Only Applicable to Contract E-001353269 Issued 1/13 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319.

More information

Electric Vibratory Box Feeder Retrofit Kit

Electric Vibratory Box Feeder Retrofit Kit Instruction Sheet P/N 008E WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Description This

More information

Low-Pressure Color Change Manifold

Low-Pressure Color Change Manifold Low-Pressure Color Change Manifold Customer Product Manual Issued 0/03 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 33-939 or contact your local

More information

Upgrading the Sure Coat Modular Gun Control System

Upgrading the Sure Coat Modular Gun Control System Instruction Sheet P/N 007365B Upgrading the Sure Coat Modular Gun Control System WARNING: Read the Safety section in the Sure Coat Modular Gun Control System manual before performing any of the following

More information

Trilogy Air-Assisted Airless Manual Spray Gun

Trilogy Air-Assisted Airless Manual Spray Gun Trilogy Air-Assisted Airless Manual Spray Gun Customer Product Manual Issued 12/15 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact

More information

Electrostatic System Checks

Electrostatic System Checks Instruction Sheet P/N Electrostatic System s WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation.

More information

Prodigy HDLV System Troubleshooting - Generation III

Prodigy HDLV System Troubleshooting - Generation III Prodigy HDLV System Troubleshooting - Generation III Instruction Sheet P/N 1081071-05 Use the procedures listed in this document to isolate and correct common problems with Prodigy HDLV Systems. Refer

More information

RA-20 Rotary Atomizer

RA-20 Rotary Atomizer RA-20 Rotary Atomizer Customer Product Manual Issued 3/18 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

Installation Instructions for Aux 101 Kit A044Z055

Installation Instructions for Aux 101 Kit A044Z055 Instruction Sheet 7-2013 Installation Instructions for Aux 101 Kit A044Z055 1 Introduction The information contained within is based on information available at the time of going to print. In line with

More information

Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder

Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder Instruction Sheet P/N 6480-0 Encore and Spectrum (Global) Powder Feed Center Clamping Cylinder WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in

More information

EP-2 Si Three-Piston Pump

EP-2 Si Three-Piston Pump EP- Si Three-Piston Pump Customer Product Manual Issued 0/ For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) -99 or contact your local Nordson representative.

More information

Encore HD Mobile Powder Coating System

Encore HD Mobile Powder Coating System Quick Start Guide P/N 1608259-02 Encore HD Mobile Powder Coating System Encore HD Mobile System Components COMPONENTS REQUIRED FOR INSTALLATION Preassembled Mobile System Encore HD Spray Gun with Cable

More information

A7A Single and Dual Automatic Airless Spray Guns

A7A Single and Dual Automatic Airless Spray Guns A7A Single and Dual Automatic Airless Spray Guns Customer Product Manual Issued 8/06 For parts and technical support, call the Finishing Customer Support Center at (800) 433-939. This document is available

More information

Circulating and Non-Circulating Color Change Manifolds

Circulating and Non-Circulating Color Change Manifolds Circulating and Non-Circulating Color Change Manifolds Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about

More information

CleanSpray XT Spray Guns

CleanSpray XT Spray Guns CleanSpray XT Spray Guns Customer Product Manual Issued 05/12 For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change without notice.

More information

Trilogy GP Air Spray and LVLP Gravity Fed Manual Spray Guns

Trilogy GP Air Spray and LVLP Gravity Fed Manual Spray Guns Trilogy GP Air Spray and LVLP Gravity Fed Manual Spray Guns Customer Product Manual Issued 7/13 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319

More information

D Instructions/Parts. Siphon Feed Detail Spray Gun D

D Instructions/Parts. Siphon Feed Detail Spray Gun D Instructions/Parts D-5-55 Siphon Feed Detail Spray Gun FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309991D Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

More information

EP2 Pump System. Customer Product Manual Part A02

EP2 Pump System. Customer Product Manual Part A02 EP2 Pump System Customer Product Manual Issued 5/08 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your local Nordson representative.

More information

EP-2 Three-Piston Pump

EP-2 Three-Piston Pump EP- Three-Piston Pump Customer Product Manual Issued 0/ For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) -99 or contact your local Nordson representative.

More information

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup. Instructions/Parts MGFHVLP Mini Gravity Feed System FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309989E For gravity feed spraying of automotive colors and clears. Ideal for touch-up and detail work. Important

More information

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A Nordson Corporation OPERATOR S CARD P/N 052644A VL400 Melters Safety WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other

More information

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11 Part A, Section 3 This section covers the following unit configurations. Model All Voltage 1, 2, 3 Pump All Manifold All Control Vista Standard (V) A 3-0 A 3-1 Section A 3 WARNING: Allow only qualified

More information

Cyclo-Kinetic Powder Coating Booths

Cyclo-Kinetic Powder Coating Booths Cyclo-Kinetic Powder Coating Booths Customer Product Manual Part 107115C NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products.

More information

Mobile Powder Spray System Dolly with Hopper for Cable-Fed Systems

Mobile Powder Spray System Dolly with Hopper for Cable-Fed Systems Instruction Sheet P/N Mobile Powder Spray System Dolly with Hopper for Cable-Fed Systems WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document

More information

PRO Auto Xs Air Spray Gun

PRO Auto Xs Air Spray Gun Instructions/Parts List ELECTROSTATIC, FOR WATERBORNE COATINGS PRO Auto Xs Air Spray Gun 309457G EN Part No. 244591, Series A 100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure 100 psi (0.7 MPa, 7 bar)

More information

T1-Titanium Non-HVLP Spray Gun

T1-Titanium Non-HVLP Spray Gun T1-Titanium Non-HVLP Spray Gun THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

More information

SureMix Dispensing System

SureMix Dispensing System SureMix Dispensing System Customer Product Manual 1061906A Issued October 2005 NORDSON CORPORATION AMHERST, OHIO USA Safety...................................... 1 Qualified Personnel.......................

More information

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure INSTRUCTIONS DP-6376 Airless Spray Gun 5000 psi (345 bar) Maximum Working Pressure INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Table of Contents Warnings......................................

More information

Installation Instructions for Load Management Kit A051C329

Installation Instructions for Load Management Kit A051C329 Instruction Sheet 12-2014 Installation Instructions for Load Management Kit A051C329 1 Introduction The information contained within is based on information available at the time of going to print. In

More information

0 8 CC Accu-Drop Ejector Dispense Gun

0 8 CC Accu-Drop Ejector Dispense Gun 0 8 CC Accu-Drop Ejector Dispense Gun Customer Product Manual Issued 03/17 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) 433-9319 or contact your

More information

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G) Part A, Section 3 Model This section covers the following unit configurations. Voltage 4 3100V 3400V 3500V Pump Piston (E, F, or G) Manifold Control 4-Port (A) 6-Port (B) Vista Temperature (TC) A 3-0 A

More information

Kinetix Electrostatic Spray Gun Automatic Version 60 kv Air Spray and KVLP Waterborne

Kinetix Electrostatic Spray Gun Automatic Version 60 kv Air Spray and KVLP Waterborne Kinetix Electrostatic Spray Gun Automatic Version 60 kv Air Spray and KVLP Waterborne Customer Product Manual Issued 8/08 For parts and technical support, call the Industrial Coating Systems Customer Support

More information

Mudhen Portable Slurry System Owners Manual

Mudhen Portable Slurry System Owners Manual Mudhen Portable Slurry System Owners Manual Industrial Contractors Supplies, Inc. 412. 824. 6933 www.icscompany.net Mudhen Manual Page 1 MUDHEN MANUAL 1 Disclaimer & Safety Notice 2 2 Safety Notice 3 3

More information

Prodigy Color-on-Demand System Generation III

Prodigy Color-on-Demand System Generation III Prodigy Color-on-Demand System Generation III Customer Product Manual Issued 8/8 For parts and technical support, call the Industrial Coating Systems Customer Support Center at (800) -99 or contact your

More information

Instructions/Parts List. WB100 Isolation System and PRO Xs3 Spray Gun K ELECTROSTATIC, WATERBORNE, AIR SPRAY

Instructions/Parts List. WB100 Isolation System and PRO Xs3 Spray Gun K ELECTROSTATIC, WATERBORNE, AIR SPRAY Instructions/Parts List ELECTROSTATIC, WATERBORNE, AIR SPRAY WB00 Isolation System and PRO Xs3 Spray Gun 309293K Important Safety Instructions Read all warnings and instructions in this manual. Save these

More information