abc INSTALLATION, OPERATION, & MAINTENANCE MANUAL ADDENDA 210 MKII LOW TEMPERATURE CELL SAMPLER

Size: px
Start display at page:

Download "abc INSTALLATION, OPERATION, & MAINTENANCE MANUAL ADDENDA 210 MKII LOW TEMPERATURE CELL SAMPLER"

Transcription

1 abc INSTALLATION, OPERATION, & MAINTENANCE MANUAL ADDENDA 20 MKII LOW TEMPERATURE CELL SAMPLER This Jiskoot Product is designed to provide outstanding service if correctly installed, used and maintained recognising the effects of the process conditions (temperature, pressure, wax/pour point, sediment, etc.). Truly representative sampling of crude oils etc., cannot be achieved by one single product in isolation. A well designed system and operating procedures as laid down in the Sampling Standards ISO 37, API 8.2 and IP Chapter VI section 2 are mandatory. Please consult Jiskoot for further information and assistance. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Jiskoot Autocontrol Ltd. 200 Jiskoot Autocontrol Ltd. All rights reserved.

2

3 20 MkII Low Temperature Cell Sampler TABLE OF CONTENTS INTRODUCTION OPERATING INSTRUCTIONS GENERAL ASSEMBLY & BILL OF MATERIAL INSTALLATION DETAILS MAINTENANCE AND TROUBLESHOOTING HEALTH AND SAFETY PRECAUTIONS MAINTENANCE RECOMMENDED SPARES LIST PRODUCT SPECIFIC DRAWINGS DISCLAIMER... 6 Issue No Page

4 20 MkII Low Temperature Cell Sampler Introduction The 20 LT Cell Sampler is an adaptation of the standard 20 Cell Sampler with an extended specification to the standard 20 Cell Sampler, designed to obtain samples from pipelines at temperatures from 70 o C to +40 o C. The principle of operation and many of the component parts are identical to the standard unit, the changes being restricted to a special seal in the Bottom Plug and an extension piece to provide thermal isolation between the Cell Sampler Body and the Actuator. 2 Operating Instructions The operation of the 20 LT Cell Sampler is exactly as described in the main 20 Cell Sampler Operating and Maintenance Manual. Issue No Page 2

5 20 MkII Low Temperature Cell Sampler 3 General Assembly & Bill Of Material Figure - 20 LT Cell Sampler ( 900# Flanged Version shown) Issue No Page 3

6 20 MkII Low Temperature Cell Sampler The following components on the 20 LT Cell Sampler differ from those fitted to the standard unit: Item No Description Item No Description 3 Actuator Spacer 47 Capture Tube 37 Sample Tube 73 Bottom Plug 38 Valve Stem 78 Special Seal 4 Installation Details The standard 20 LT Cell Sampler is designed to be bolted as a "wafer" between a pair of " ANSI 50#, ANSI 300#RF or ANSI 600#RF flanges and can withstand static pressure testing to full flange rating. Alternative flange sizes and finishes may be supplied to suit specific applications. The axis of the outlet pipe connection should be horizontal or downward facing to prevent water traps. It is crucial that the flow through the bypass loop and cell sampler is adequately mixed in regard to the properties of interest. Where sampling for water content we would normally recommend the minimum flow velocity within the cell sampler and for metre upstream exceed 3.5 m/s (6 m3/hr). The Customer is responsible for the supply of an in-line check/relief valve, rated to suit the temperature of the sample and pressure of the sampling system, to be fitted between the ¼" Swagelok Sample Outlet Port in the Bottom Plug (73) and the Sample Receiver The external Check Valve must be set to either 7 Bar above the maximum operating line pressure for low pressure receiver systems or, with the exception of installations using valves unaffected by back pressure, to Barg where line balanced high pressure sample receivers are being used (i.e. where the sample is being collected at, or close to, line pressure). The outlet of the Check Valve should be connected to the Sample Receiver System via smallbore (¼" or 6mm) stainless steel tubing. Ensure that lengths of tubing are kept to a minimum to minimise "dead" i.e. trapped volume (long lengths of tubing also create extra back pressure and premature seal wear), and that the sample travels downhill at a minimum angle of 5 degrees from the Sampler Outlet to the Receiver to avoid water traps. The sample outlet piping may require heat tracing to prevent blockage. It is the Customer s responsibility to provide adequate insulation around the Cell Sampler Body and Sample discharge pipework to prevent accidental contact by the Operator. To ensure the correct operation of the Sampler, the insulation must not extend over the finned section of the Extension Tube A Sampler Solenoid Valve must be selected to suit the specific application and will require connecting to suitable supplies via glands and cables appropriate to the area classification. Note: The correct rating fuse must be included in the Solenoid Valve supply circuit. A regulated air supply must be connected to the Solenoid and the normally energised outlet connected to Port 'B' of the Sampler. The normally de-energised port of the Solenoid must be connected to Port 'A'. The exhaust port(s) of the Solenoid may be piped away or fitted with silencers as required. (On Electro-Hydraulic applications, the Solenoid is incorporated into the Hydraulic Power Pack.) If required, the bottom port (drain cavity) of the Actuator may be connected to a closed drain or a pressure switch. The Sampler Control System must be capable of supplying a pulse of a minimum 250mS duration to the Sampler Solenoid Valve to ensure that there is sufficient time for the Sampler to complete a full stroke at each actuation (in most systems using air 500ms is normal). The Actuator should dwell momentarily at the bottom of its travel before the Solenoid is deenergised and the Sampler returns to its 'rest' state. Issue No Page 4

7 20 MkII Low Temperature Cell Sampler 5 Maintenance and Troubleshooting 5. Health and Safety precautions In addition to the basic health and safety precautions described in the standard 20 Cell Sampler Manual, care must be taken to avoid burns from exposed metal work when the sampler is in service. 5.2 Maintenance Maintenance procedures for the 20 LT Cell Sampler are identical to that for the standard unit, with the addition of the special seal fitted to the groove in the top of the Bottom Plug. 6 Recommended Spares List When requesting assistance or spare parts, please advise the Sampler Model and Serial Numbers to ensure that the correct options are supplied. Part/Sub- Assembly Commissioning Year Operation 2 Year Operation Solenoid Valve (to suit application) - Seal Kit Comprising: 4 Slydring 5 Seal 0 O Ring O Ring 22 Seal Ring 24 Sealing Washer 25 Quadring 26 O Ring 27 O Ring 28 Double Delta seal 29 O Ring 30 Spring 32 Seal 36 Gaiter 2 4 O Ring 42 Star Washer 43 Spring 6 Seal 62 Slydring 75 Valve Seat 77 Spring 78 Special Balseal 79 Seal 80 Seal O Ring (Assembly Aid) 2 Special Tool Kit comprising: - - { Piston Lock Ring Removal Tool { Support Tube Nut Removal Tool { Support Tube Clamp { Sample Pillar Balseal Insertion Tool { Check Valve O Ring Removal Tool { Check Valve O Ring Insertion Tool { C Spanner for Stop Ring Issue No Page 5

8 20 MkII Low Temperature Cell Sampler 7 Product Specific Drawings Series 20 Mk II Cell Sampler (Cryogenic Version) Parts List Spare Parts List 8 Disclaimer B25257 P25260 P25269 Whilst Jiskoot Autocontrol Limited has taken every care in the preparation of this document, it cannot accept responsibility for printing errors or omissions and does not warrant that it is correct and comprehensive in every particular. Equipment supplied should always be operated by persons with an appropriate level of skill and training. Jiskoot Autocontrol Limited shall not be liable for incidental or consequential damages resulting from the furnishing, performance or use of this material. Jiskoot Autocontrol pursue a policy of continuous improvement, and information given herein may be updated without notice. Further, this information is proprietary to Jiskoot Autocontrol Limited, and must not be disclosed to any third party except as may be required to operate the equipment supplied in accordance with the purposes for which it was sold by the persons properly licensed to operate it. Minor corrections P.Whittle M.A.Jiskoot 23/3/200 Issue No Page 6

9 20 MkII Low Temperature Cell Sampler 0 First issued P.Whittle M.A.Jiskoot 3/9/999 Issue Revision History Issued Approved Date Issue No Page 7

10 20 MkII Low Temperature Cell Sampler Notes Issue No Page 8

11 20 MkII Low Temperature Cell Sampler Notes Issue No Page 9

12 20 MkII Low Temperature Cell Sampler Notes Issue No Page 0

13 20 MkII Low Temperature Cell Sampler Notes Issue No Page

14 20 MkII Low Temperature Cell Sampler Notes Issue No Page 2

15

16 DEF Tunbridge Wells, Kent, TN 2DJ, UK Tel +44 (0) , Fax +44 (0) DEF Houston, TX7704, USA Tel , Fax jinc@jiskoot.com

abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR SERIES 210 HI-TEMP SAMPLER 4 150LB BITUMEN SAMPLER

abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR SERIES 210 HI-TEMP SAMPLER 4 150LB BITUMEN SAMPLER abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR SERIES 210 HI-TEMP SAMPLER 4 150LB BITUMEN SAMPLER This Jiskoot Product is designed to provide outstanding service if correctly installed, used and

More information

abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR SERIES 210 MK.II SAMPLE PROBE

abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR SERIES 210 MK.II SAMPLE PROBE abc OPERATING, INSTALLATION & MAINTENANCE MANUAL FOR SERIES 210 MK.II SAMPLE PROBE This Jiskoot Product is designed to provide outstanding service if correctly installed, used and maintained recognising

More information

Installation and Maintenance Instructions for Grinnell GRP Pneumatic Rack and Pinion Actuators

Installation and Maintenance Instructions for Grinnell GRP Pneumatic Rack and Pinion Actuators FLOW CONTROL for Introduction The Grinnell GRP Pneumatic Actuator is a compact, rack & pinion design, conforming to Grinnell standard or direct mount standards or EN ISO 5211 mounting configuration, depending

More information

Systems. In-line Blending. Solutions you can trust

Systems. In-line Blending. Solutions you can trust In-line Blending Systems In-line Blending Solutions you can trust Blending In-line Blending In-line Blending is the controlled, continuous mixing of a number of components to produce a finished product

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override) SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override) Selection, Application and Maintenance Valve Numbers SVX-320 SVX-330 SVX-520

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR INSTRUMENT ISOLATION VALVE

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR INSTRUMENT ISOLATION VALVE PAGE : 01 OF 07 INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR INSTRUMENT ISOLATION VALVE PREPARED BY CHECKED BY APPROVED BY NAME M.Bhuvaneswari Y.Nesabalan M.Selvam DATE 22-Mar-201 19-Nov-2013 22-Nov-2013

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP MODEL SSO-9MED DRAWING NUMBERS AD243DI AD243DK AD243DK.K1 MANUAL NUMBER IOM-175 REVISION Rev. B, 3/21/2017 TABLE OF CONTENTS

More information

Installation and Maintenance Instructions for Morin MRP Pneumatic Rack and Pinion Actuators

Installation and Maintenance Instructions for Morin MRP Pneumatic Rack and Pinion Actuators for Morin MRP Pneumatic Rack and Pinion Actuators Introduction The Morin MRP Pneumatic Actuator is a compact, rack & pinion design, conforming to Keystone standard or direct mount standards or EN ISO 5211

More information

2-12 Grooved End Dual Disc Check Valve. Operation, Maintenance and Installation Manual

2-12 Grooved End Dual Disc Check Valve. Operation, Maintenance and Installation Manual Manual No. DDCV-OM4-1 2-12 Grooved End Dual Disc Check Valve Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP MODEL SSO-8 DRAWING NUMBERS AD148CF AD148CG AD148CO AD148CQ AD500CA MANUAL NUMBER IOM-065 REVISION Rev. A, 8/17/2016 TABLE OF CONTENTS

More information

High Pressure Bypass System Type SOV acc. to TRD 421

High Pressure Bypass System Type SOV acc. to TRD 421 High Pressure Bypass System Type SOV acc. to TRD 421 GS valve engineering GmbH Phone: +49-208-833 2090 sales@gs-valve.eu Duisburger Strasse 375 Fax: +49-208-833-2095 www.gs-valve.eu 46049 Oberhausen GERMANY

More information

A Member of the. Integrated Metering Technologies

A Member of the. Integrated Metering Technologies I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and Safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe

More information

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5 Combiner Manual i ii Combiner Manual Combiner Manual Copyright 2004 SMA America, Inc. All rights reserved. All rights reserved. No part of this document may be reproduced, stored in a retrieval system,

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER Signal Group Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302 e-mail: instruments@signal-group.com

More information

Wafer and Globe Style Silent Check Valve. Operation, Maintenance and Installation Manual

Wafer and Globe Style Silent Check Valve. Operation, Maintenance and Installation Manual Manual No. SCV-OM1-4 Wafer and Globe Style Silent Check Valve Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2

More information

OCTOPUS 45mm Bore Linear Actuator Sailboat Drive Style LAR

OCTOPUS 45mm Bore Linear Actuator Sailboat Drive Style LAR INSTALLATION MANUAL OCTOPUS 45mm Bore Linear Actuator Sailboat Drive Style LAR OC1674 2 Revision History Revision A Description Released in Book Format 2009 Octopus Products Inc. All rights reserved. The

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INLOOP CRUDE OIL SAMPLER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INLOOP CRUDE OIL SAMPLER INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INLOOP CRUDE OIL SAMPLER DRAWING NUMBERS AD585CI AD659CI AD659CP AD842BB MANUAL NUMBER IOM-029 REVISION Rev. F, 8/8/2016 TABLE OF CONTENTS SAFETY

More information

Clif Mock. CD20 (12VDC) Sampler Drive. User Manual. Manual No A

Clif Mock. CD20 (12VDC) Sampler Drive. User Manual. Manual No A Clif Mock CD20 (12VDC) Sampler Drive User Manual Manual No. 20165008A 2004 NuFlo Technologies, Inc. All information contained in this publication is confidential and proprietary property of NuFlo Technologies,

More information

introduction FE Series Butterfly Valves Product Data Sheet

introduction FE Series Butterfly Valves Product Data Sheet Product Data Sheet introduction < STANDARDS > ASTM D1784 IPEX FE Series Butterfly Valves incorporate many features of our industrial FK valve, yet the all PVC construction and EPDM liner make this valve

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CRUDE OIL COLLECTION ASSEMBLY HIGH PRESSURE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CRUDE OIL COLLECTION ASSEMBLY HIGH PRESSURE INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER CRUDE OIL COLLECTION ASSEMBLY HIGH PRESSURE MODEL AWL-3HP DRAWING NUMBER AD489AP MANUAL NUMBER IOM-116 REVISION Rev. C, 4/6/2018 TABLE OF CONTENTS

More information

APT14 Automatic Pump Trap Installation and Maintenance Instructions

APT14 Automatic Pump Trap Installation and Maintenance Instructions 6120250/7 IM-P612-04 ST Issue 7 APT14 Automatic Pump Trap Installation and Maintenance Instructions 1 Product information 2 Operation 3 Installation Closed loop steam systems only 4 Commissioning 5 Maintenance

More information

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Installation and operating manual Quick closing valve (Bellow sealed) LK product no: LK product no: 902002 Article no: 74506 Revision: 2 Contents 1. General information... 3 2. Safety precautions... 3 2.1 Significance of symbols... 3 2.2 Explanatory notes on safety information... 3 3.

More information

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H USER NOTE: This addendum serves as additional information for Pulsafeeder PULSAR and PULSAR Shadow metering pumps equipped with

More information

SEries 41 check valve installation, operation & maintenance manual

SEries 41 check valve installation, operation & maintenance manual Instruction for use Thank you for selecting an AVK product. With correct use, it will give long and reliable service. This manual has been prepared to assist you install, operate and maintain the valve

More information

introduction FK Series Butterfly Valves Product Data Sheet

introduction FK Series Butterfly Valves Product Data Sheet Product Data Sheet introduction < STANDARDS > ASTM D4101-86 ASTM D1784 ASTM D3222 IPEX FK Series Butterfly Valves offer superior strength and chemical resistance in highly corrosive environments and process

More information

80V 300Ah Lithium-ion Battery Pack Data Sheet

80V 300Ah Lithium-ion Battery Pack Data Sheet 80V 300Ah Lithium-ion Battery Pack Data Sheet 80 V, 300 amp-hour capacity, maintenance-free energy storage, IP65 design, fully integrated BMS, integrated fuse and safety relay protection, highly configurable

More information

Installation and operating manual

Installation and operating manual LK product no: 901002 and 901102 501002 and 501102 (JIS) Article no: 74500 Revision: 9 Article no: 74500 Revision: 9 2 (23) Contents 1. General information... 5 2. Safety precautions... 5 2.1 Significance

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER FIXED INSERTION

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER FIXED INSERTION INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INFLOW ACE CRUDE OIL SAMPLER FIXED INSERTION DRAWING NUMBER AD887AC MANUAL NUMBER IOM-178 REVISION Rev. 0, 7/8/2016 TABLE OF CONTENTS SAFETY 3 1.

More information

KAM E-IAS ELECTRIC ISOKINETIC AUTOMATIC SAMPLER

KAM E-IAS ELECTRIC ISOKINETIC AUTOMATIC SAMPLER KAM E-IAS ELECTRIC ISOKINETIC AUTOMATIC SAMPLER PER API 8.2, ASTM D4177 AND ISO 3171 User Manual EIASMANUAL0718 TEL +1 713 784-0000 FAX +1 713 784-0001 Email Sales@Kam.com 3939 Ann Arbor Drive Houston,

More information

Introduction. Globe and Angle Body Control Valves. In Line Valve provides Solutions to Flow Control

Introduction. Globe and Angle Body Control Valves. In Line Valve provides Solutions to Flow Control Introduction Globe and Angle Body Control Valves In Line Valve provides Solutions to Flow Control In Line Valve Globe Control Valves use the variable area generated between the plug and seat to control

More information

14 and Larger Wafer and Lug Style Dual Disc Check Valve. Operation, Maintenance and Installation Manual

14 and Larger Wafer and Lug Style Dual Disc Check Valve. Operation, Maintenance and Installation Manual Manual No. DDCV-OM2-2 14 and Larger Wafer and Lug Style Dual Disc Check Valve Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION...

More information

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Teknigas Black Teknigas Black Teknigas Black Teknigas Black Teknigas Black Teknigas

More information

JISKOOT Bunker Blending

JISKOOT Bunker Blending JISKOOT Bunker Blending The goal of any bunker supplier is to blend bunker fuel at the lowest cost to meet a customer s specification.rising costs and fluctuations in feedstock quality make this more difficult

More information

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant

More information

TRUNNION MOUNTED METAL SEATED BALL VALVES

TRUNNION MOUNTED METAL SEATED BALL VALVES TRUNNION MOUNTED METAL SEATED BALL VALVES HIGH PERFORMANCE BALL VALVES FOR SEVERE SERVICES PROCESS VALVES STANDARD FEATURES FOR SIDE ENTRY & BOTTOM ENTRY DESIGN 1. Trunnion Mounted The ball is trunnion

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Cam-Tite Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2

More information

T1/T2 HYDRAULIC RAM INSTALLATION & SERVICE HANDBOOK

T1/T2 HYDRAULIC RAM INSTALLATION & SERVICE HANDBOOK T1/T2 HYDRAULIC RAM INSTALLATION & SERVICE HANDBOOK SERIAL NUMBER NOTIFICATION The information contained in this document is subject to change without prior notice. Navico UK Ltd. shall not be liable for

More information

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes Combiner Manual SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes User Manual U.S. Version 2.4 DOC-CBUG-01 i ii Combiner Manual Combiner Manual Copyright 2012 SMA America, LLC. All rights reserved.

More information

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood HAZARD POTENTIALS disregarding of instructions improper use of product insufficiently qualified personnel Valve application to be

More information

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares Instruction replacement procedure INS/ANAINST/025 EN Rev. A Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares Kit references: flowcell, tundish, flowmeter,

More information

Lease Automatic Custody Transfer

Lease Automatic Custody Transfer Lease Automatic Custody Transfer Angus Manufactured LACT Units Updated 19-Dec-01, Slide 2 LACT Unit Requirements Are used for the automatic unattended measurement of crude oil. Accurately measure the quantity

More information

TFA Flowmeter for Saturated Steam Service Installation and Maintenance Instructions

TFA Flowmeter for Saturated Steam Service Installation and Maintenance Instructions 1930051/2 IM-P193-03 MI Issue 2 TFA meter for Saturated Steam Service Installation and Maintenance Instructions This guide must be read in conjunction with the Installation and Maintenance Instructions

More information

STYLE B THERMOSTATIC TEMPERATURE REGULATOR

STYLE B THERMOSTATIC TEMPERATURE REGULATOR STYLE B THERMOSTATIC TEMPERATURE REGULATOR MIL-V-19772A and MIL-DTL-19772B TYPE I (3-WAY) / TYPE II CLASS 1 / TYPE II CLASS 2 WITH MANUAL OVERRIDE and OVERHEAT PROTECTION SUITABLE FOR SHIPBOARD SERVICE

More information

HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES

HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES 1-4470 SERIES - 2 - DESCRIPTION HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES 1-4470 SERIES Parcol 1-4470 High Temperature High Pressure Control Valves represent

More information

Installation and Operating Guidelines Battery Back-up Pump System

Installation and Operating Guidelines Battery Back-up Pump System Installation and Operating Guidelines Battery Back-up Pump System www.tritonsystems.co.uk 1 Contents 1.0 Product Summary... 3 2.0 Installation Guidelines... 3 3.0 Technical Specification... 4 4.0 Dimensions...

More information

AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES

AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES TABLE OF CONTENTS GENERAL SERIES 854(TYPICAL EXPLODED VIEW) COMPONENT LIST INTRODUCTION TO AVK/GLENFIELD SERIES

More information

PRESSURE REDUCING AND DESUPERHEATING STATIONS SERIES

PRESSURE REDUCING AND DESUPERHEATING STATIONS SERIES PRESSURE REDUCING AND DESUPERHEATING STATIONS 1-5700 SERIES - 2 - I.P. to condenser bypass valve 1-5765 - Inlet: DN 30 ANSI 900 BW - Outlet: DN 60 ANSI 300 BW - Port : 443 mm Body material: SA182 F91 /

More information

OPERATING SERVICE MAINTENANCE MANUAL

OPERATING SERVICE MAINTENANCE MANUAL OPERATING SERVICE MAINTENANCE MANUAL ALL-STAR ROCKING PISTON COMPRESSOR AND VACUUM PUMP Registered by one or more of these standards agency ISO RoHS 9001 Compliant CE Read through carefully and understand

More information

OPERATING MANUAL C-1350 CABLE PUSHER. Copyright 2003 by CBS Products (KT), Ltd

OPERATING MANUAL C-1350 CABLE PUSHER. Copyright 2003 by CBS Products (KT), Ltd CBS Products (KT), Ltd, Pillings Road, Oakham, Rutland, LE15 6QF. UK Telephone: +44(0)1572723665 Fax: +44(0)1572 756006 E-Mail: sales@cbsproducts.com Website:www.cbsproducts.com OPERATING MANUAL C-1350

More information

Rectangular Door L-VAT with pneumatic actuator double acting

Rectangular Door L-VAT with pneumatic actuator double acting Rectangular Door L-VAT with pneumatic actuator double acting This manual is valid for the products: 0 7 5 1 0 U A 2 4 0 0 0 1 4 character option code Size 10... 46 x 236 12... 50 x 336 Actuator 24... without

More information

HIGH PERFORMANCE BUTTERFLY VALVE MODEL HP300 SERIES

HIGH PERFORMANCE BUTTERFLY VALVE MODEL HP300 SERIES FEATURES AND BENEFITS Wafer & Lugged bodied butterfly valves for bi-directional use Dead end service are offered as standard in full ANSI Class and ratings (for lugged design only) The design of double

More information

Installation and user s guide H A. TP20 probe for FARO arm

Installation and user s guide H A. TP20 probe for FARO arm Installation and user s guide H-1000-5131-01-A TP20 probe for FARO arm 2007 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any other

More information

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range) D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range) Selection, Application and Maintenance D29, D30, D41, D34BF, D35B, D39BF, D29-AM, D30-AM, D41-AM D34BF-AM, D35BF-AM, D39BF-AM CE209 (8)_d_series_mini

More information

GLOBE 3 WAY CONTROL VALVE SERIES INTRODUCTION

GLOBE 3 WAY CONTROL VALVE SERIES INTRODUCTION GLOBE 3 WAY CONTROL VALVE SERIES - 130 INTRODUCTION Pneucon' 3 way control valves are used to combine two flows or to divert one flow into two outlets. They are designed to replace and perform the functions

More information

KAM IAS ISOKINETIC AUTOMATIC SAMPLER. User Manual IASMANUAL-0513 KAM CONTROLS, INC Ann Arbor Drive Houston, Texas USA

KAM IAS ISOKINETIC AUTOMATIC SAMPLER. User Manual IASMANUAL-0513 KAM CONTROLS, INC Ann Arbor Drive Houston, Texas USA An ISO 900 certified company TEL + 73 784-0000 FAX + 73 784-000 Email Sales@Kam.com KAM IAS ISOKINETIC AUTOMATIC SAMPLER PER API 8.2, ASTM D477 AND ISO 37 User Manual IASMANUAL-053 3939 Ann Arbor Drive

More information

Automatic Sampling/Quality Measurement Crude Oil. Crude Oil Quality Association San Antonio, TX March 7, 2013

Automatic Sampling/Quality Measurement Crude Oil. Crude Oil Quality Association San Antonio, TX March 7, 2013 Automatic Sampling/Quality Measurement Crude Oil Crude Oil Quality Association San Antonio, TX March 7, 2013 Crude Quality Why the sample is important A sample is the basis upon which we acknowledge receipt

More information

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life! Instructions and operation manual for butterfly valves This manual is intended to support the users of Herberholz butterfly valves type HRD/HRA, RD/RA, LDKE/LDKF for installation, operation and maintenance

More information

Operating Instructions

Operating Instructions 16 1 Independent & Unauthorized Changes and Spare Parts Alterations and changes to actuators are only possible, i.e. permitted under express permission from the company airpower Europe GmbH. These conditions

More information

Easytork Vane Actuator IOM

Easytork Vane Actuator IOM Easytork Vane Actuator IOM General Storage The Easytork Vane Actuator ( EVA ) is a high-quality product and as such must be handled, transported and stored with care. Prior to storage, inspect the actuator

More information

NEOTECHA NEOSEAL BUTTERFLY VALVE INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NEOSEAL BUTTERFLY VALVE INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

Manual No: Revision: F. Mag Probe Assembly Manual

Manual No: Revision: F. Mag Probe Assembly Manual Manual No: 576013-730 Revision: F Mag Probe Assembly Manual Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of merchantability

More information

Eim Controls THE G SERIES GAS ACTUATOR. Re-designed for another half century of service to the pipeline industry.

Eim Controls THE G SERIES GAS ACTUATOR. Re-designed for another half century of service to the pipeline industry. Eim Controls THE G SERIES GAS ACTUATOR Re-designed for another half century of service to the pipeline industry. EIM was the innovator in direct gas valve actuation. In fact, EIM was founded in 199 on

More information

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:

3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: 3-20 2FII & Groundhog Bonded Seat Butterfly Valve Operation and Maintenance Manual Job Name: Contractor: Date: Document #:3202FIIGD Revision Date: 1/10/11 SAFETY MESSAGES All safety messages in the instructions

More information

16000SIII Automatic Grease System

16000SIII Automatic Grease System Manual # 99905495 16000SIII Automatic Grease System Effective 20120716 IOWA MOLD TOOLING CO., INC. PO Box 189 Garner, IA 50438 Tel: 641-923-3711 FAX: 641-923-2424 Website: http://www.imt.com Copyright

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Series PBV Plastic Lined Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health

More information

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk Black Teknigas Powerseat Eco Gas Safety Shut-Off Valve Technical, and Maintenance Details WattsIndustries.co.uk Safety shut off valves for gas, air and oil EN161 approved; EC certificated Robust construction

More information

Contents. 1. Preface Change record Fuse Replacement...5. MPU fuses...5

Contents. 1. Preface Change record Fuse Replacement...5. MPU fuses...5 Fuse Replacement Contents 1. Preface... 2. Change record...4. Fuse Replacement...5.1.2..4.5.6.7 ii MPU fuses...5 X1 fuses...6 X2 fuses...7 Y/Z fuses...8 Tool Rotation/Reciprocating knife fuses...9 Chiller

More information

Installation & Technical Guide. Domestic & Commercial.

Installation & Technical Guide. Domestic & Commercial. Installation & Technical Guide Domestic & Commercial www.challisbooster.com www.challisboosterplus.com Installation and Technical Guide Domestic and Commercial Challis Water Controls Europower House, Lower

More information

PART XV Metering Systems SECTION 2 GUIDE TO GAS METERING SYSTEMS

PART XV Metering Systems SECTION 2 GUIDE TO GAS METERING SYSTEMS THE INSTITUTE OF PETROLEUM PETROLEUM MEASUREMENT MANUAL PART XV Metering Systems SECTION 2 GUIDE TO GAS METERING SYSTEMS THE INSTITUTE OF PETROLEUM PETROLEUM MEASUREMENT MANUAL PART XV Metering Systems

More information

Data Sheet BP v 100Ah LiFePO 4 (Peli TM Case Kit)

Data Sheet BP v 100Ah LiFePO 4 (Peli TM Case Kit) Data Sheet BP2589-12v 100Ah LiFePO 4 (Peli TM Case Kit) Product Name Battery Model Spec File Revision LiFePO4 Battery in Peli TM Case LiFePO4-11198141 4S5P 12.8V 100Ah A2 Amendment Records Revision Description

More information

These installation and maintenance instructions must be read in full and completely understood before the installation!

These installation and maintenance instructions must be read in full and completely understood before the installation! These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

COSASCO HYDRAULIC ACCESS FITTING User Manual

COSASCO HYDRAULIC ACCESS FITTING User Manual COSASCO HYDRAULIC ACCESS FITTING User Manual Rohrback Cosasco Systems, Inc. 11841 E. Smith Avenue Santa Fe Springs, CA 90670 Tel: (562) 949-0123 (800) 635-6898 Fax: (562) 949-3065 E-mail: sales@cosasco.com

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Wafer Style, Dual Plate Check Valves. To ensure efficient and safe operation

More information

TKD Series 3-Way Ball Valves Product Data Sheet

TKD Series 3-Way Ball Valves Product Data Sheet Product Data Sheet < SANDARDS > ASM D1784 ASM D2466 ASM D2467 ASM D2464 ASM F1498 introduction IPEX KD Series 3-Way Ball Valves can be used for flow diverting, mixing, or on/off isolation. hey will replace

More information

SERIES 2000 GAS SAFETY SHUT OFF VALVE

SERIES 2000 GAS SAFETY SHUT OFF VALVE APPLICATION 2 Series 00 Solenoid Valves are Safety Shut-off or Control Valves for use on gases in gas families 1, 2 and and are also suitable for use with air within the valves pressure range - see specification.

More information

Installation, Operation & Maintenance Manual

Installation, Operation & Maintenance Manual Original Instructions Installation, Operation & Maintenance Manual ISOLOK API-PA Sampler ISOLOK API-PE Sampler Point Samplers S-AS-IOM-00437-5 01-19 Do not install, maintain, or operate this equipment

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Probe Mounted Bypass Sample System Model LSSM-1P-SYS Drawing No.: LS3094 Manual No.: IOM-147 The information in this manual has been carefully checked

More information

Patient Care Facility

Patient Care Facility ISIMET Patient Care Facility DLA Controller Individual Room Configuration Style 1 W/ Ver 4.41 pcb & Pulse Relay pcb Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for

More information

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS INTRODUCTION The two most common methods of measuring the volume of petroleum liquids are tank gauging and liquid metering. The problems associated with

More information

SUPER PUMP OUT SYSTEM

SUPER PUMP OUT SYSTEM Congratulations on your purchase of the SUPER PUMP OUT SYSTEM. This instruction/parts manual is a guide for operating and servicing your BLUELINE SUPER PUMP OUT SYSTEM. Proper operation and service are

More information

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions ISIMET Drug Testing Labs DLA Controller Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for Canadian Industrial Control

More information

DK Series Pneumatic Diaphragm Valves Product Data Sheet

DK Series Pneumatic Diaphragm Valves Product Data Sheet 1" through 2-1/2" 1/2" and 3/4" < STANDARDS > ASTM D1784 ASTM D1785 ASTM D4101 ASTM D3222 ASTM D2464 ASTM D2466 ASTM D2467 ASTM F441 ASTM F437 ASTM F439 ASTM F1498 IPEX DK Series are the ideal solution

More information

WIRELESS STEERING INSTALLATION MANUAL

WIRELESS STEERING INSTALLATION MANUAL WIRELESS STEERING INSTALLATION MANUAL Type H System For Hydraulic Steering Systems OC14278 Page 2 of 14 Revision History Revision Description NEW First Edition A Second Edition B Third Edition 2013 Octopus

More information

Katharometer Power Supply Units

Katharometer Power Supply Units Instruction Manual IM/4234600 Rev. D Katharometer Power Supply Units 4234 600 & 4234 601 ABB The Company EN ISO 9001:1994 We are an established world force in the design and manufacture of instrumentation

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

SELF PRIMING CHEMICAL SERVICE PUMPS

SELF PRIMING CHEMICAL SERVICE PUMPS SELF PRIMING CHEMICAL SERVICE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS This Manual covers: SELF PRIMING MODEL RANGE J50ECX TO J250ECX STAINLESS STEEL*, and NON METALLIC SEAL PUMP MODEL: SERIAL NO:

More information

introduction TKD Series 3-Way Automated Ball Valves Product Data Sheet

introduction TKD Series 3-Way Automated Ball Valves Product Data Sheet Product Data Sheet introduction < STANDARDS > ASTM D1784 ASTM D2464 ASTM D2466 ASTM D2467 ASTM F1498 ASTM F437 ASTM F439 IPEX TKD Series 3-Way Automated Ball Valves can be used for flow diverting, mixing,

More information

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions 3579049/14 IM-P357-29 CTLS Issue 14 PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions PN9100 PN9200 1. Safety information 2. General product information PN9300 3. Installation

More information

STORM Guardian. Operator s Handbook

STORM Guardian. Operator s Handbook STORM Guardian Operator s Handbook COPYRIGHT The copyright in this document which contains proprietary information is vested in CASELLA. The contents of this document must not be used for purposes other

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Series PBFV Plastic Lined Butterfly Valve - Lug and Wafer Style Table of Contents Table of Contents Introduction and Safety...2 Safety

More information

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822 Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822 Statements: NIBCO High Performance Butterfly Valves, Series 6822 and 7822, have been designed

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation Actuators Maintenance...

INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation Actuators Maintenance... INSTALLATION, OPERATION & MAINTENANCE MANUAL INDEX Page 0- Description 2 1- Handling 2 2- Installation 2 3- Actuators 5 4- Maintenance 5 41- Gland packing replacement 5 42- Seal replacement 6 43- Gasket

More information

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions 4034450/9 IM-P403-15 AB Issue 9 BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions 1. Safety information 2. Application 3. Technical data 4. Operation 5. Installation 6. Rotating

More information

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Date of Issue: 04 August 2010 Page 1 of 27 QF 80: Issue 2 WARNING! BEFORE ANY INSTALLATION AND MAINTENANCE WORK CAN COMMENCE ENSURE THE VALVE AND SURROUNDING

More information

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31 LACT MEASUREMENT Prepared By: Ken A. Steward. P.E. Linco-Electromatic, Inc. 4580 West Wall Street Midland, Texas 79703 The Operation of L.A.C.T. Units The simplest approach to the understanding of the

More information

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS WARNING This manual, and the GENERAL INSTRUCTION MANUAL SRM00046, should be read thoroughly prior to pump installation, operation or maintenance. Manual No. SRM00095

More information

Operation Notes and Alignment Instructions

Operation Notes and Alignment Instructions Technical Note 814 Valco Instruments Co. Inc. Operation Notes and Alignment Instructions Air and Electrically* Actuated Cheminert Multiposition Valves *For a microelectric actuator, refer to Technical

More information