1 Mercury Advance Alternating Cushion User Manual
2 Mercury Advance Alternating Cushion The Dyna-Pad Mercury Advance Alternating Cushion is a Very High Risk dynamic replacement seating system, combined with the benefits of modern foam technology. Offering high levels of patient comfort, this unique system has the facility to step up to that of a dynamic cushion when clinically required. Similarly, the cushion s function can be downgraded as the patient s condition improves. A higher maximum weight capacity, up to 24 stone / 152kg, allows the product to meet the modern challenges of those heavier clients. The outer cover comprising a high frequency welded, multi stretch and vapour permeable fabric satisfies the strictest infection control policies. Designed using the latest medical grade cell technology to create greater postural management and pressure relief, this product is specifi cally made for users considered to be at Very High Risk of pressure ulcer development and those with minor postural issues. Contents 1. Introduction Quick Reference Guide & Frequently Used Functions Troubleshooting Installation Operation Transportation Audible Warnings Maintenance Procedures Technical Data Optimum Conditions for Use Symbols Guide & Contraindications for Use Detachable / Removable Parts Disposal
3 USER MANUAL 1. Introduction The cushion consists of a foam head cell and series of 4 transverse air cells, each containing a unique foam profiled insert, which are in turn held within a foam base, all protected by a vapour permeable waterproof cover. The transverse cells are arranged to alternate in a sequence to increase and decrease pressure over the thighs, coccyx and ischial areas. The digitally controlled Power Unit controls a pump that allows air to flow into, or out of the air cells as required according to the operating mode selected. It also maintains the air pressure within the cushion at the required level and controls the action of the audible/visual Audible Warning system in the event of mains supply failure or over or under inflation pressure. 2. Quick Reference Guide (Frequently used functions) This is a quick reference guide for the Dyna-Pad Mercury Advance Alternating Cushion Product Code CUSH/ADV/ALT/46/46/10 Power Switch Audible Warning Reset The power switch simply switches the mains power to the pump on and off. When the pump detects an Audible Warning condition, this can be silenced as below and reset by switching the pump off and then back on again. Pump Connector Please ensure that the Pump connector is always placed fully home, prior to inflating the cushion. NB: The cushion will NOT inflate properly should this not be the case. 3
4 LED Mode Settings This symbol when illuminated (The green indicator light) is not used to indicate that the equipment is on or ready for use. When a patient requires a true dynamic function or indeed more pressure in the cells, as they may be uncomfortable or feel as though the support surface is too soft or unstable, then please select a High setting (pressure 26mmHg). This must only be used by a trained clinician as often too high pressures can further agitate certain patient conditions. Power On / Off True Dynamic /Firmer Setting When a patient requires less pressure in the cells, as they may be uncomfortable or indeed hyper sensitive to cell movement or indeed if the patient is still reddening further, then please select a Low setting (pressure 18mmHg). This must only be used by a trained clinician. Low / Comfort Pressure Setting This function is used to silence the Audible Warning. The LED will remain lit if the Audible Warning has been silenced previously, however a fault is still detected. Refer to the power switch in order to re-set fully. If the Audible Warning continues to sound repeatedly, along with an illuminated light, then an engineer must be called. Silence Audible Warning This symbol indicates an Audible Warning Failure. Please see troubleshooting guide below for how to re-set. Audible Warning Failure This symbol when illuminated indicates a Service is required. DHS recommends a service every 8760 hours of operation (one continuous year running). Service Indicator Note: Please ensure (when available) that all securing straps on the base of the cushion are secured onto the NON MOVING PARTS of the chair. For shut down procedure, see 4.2 Power Unit (Pump) section. 4
5 USER MANUAL 3. Troubleshooting Warning / Fault Control Unit does not operate; no display lights illuminate Warning LED C Warning LED B Warning LED B+C Cause The Control Unit may not be attached to a power source or a fuse may need replacing. Mains failure / Other See above, plus: Pressure too low Pressure too low / Air pipe kinked Solution 1. Check the Control Unit is connected to mains power outlet with the correct voltage. 2. Check the Control Unit is switched on. Switch off and unplug the unit before restarting. 3. Check the mains plug fuse (5 AMP) then check both Control Unit fuses (1 AMP) fuses can be released using a screwdriver to push and turn. Do not try to open the Control Unit. Opening the unit could cause personal injury or equipment damage. Ensure the replacement of fuses is carried out accordance with local legislation. 1. Reset the audible warning turn off power and press the audible warning mute button. 2. Check the handle is intact, ensuring all four sealing connectors are firmly fitted to the control unit and the air hoses. Check the CPR tag is attached and all sealing connectors are firmly secure. 3. Check all air hoses along the inside of the cushion each should be firmly connected. Check each air cell is securely attached to its connecting air pipe. 4. Check all cells, pipes and hoses for any air leakage. 5. Switch on power. 1. Reset the warning turn off power and press the audible warning mute button. 2. Check the handle is intact, ensuring all four sealing connectors are firmly fitted to the control unit and the air hoses. Check the CPR tag is attached and all sealing connectors are firmly secure. 3. Check all air hoses along the inside of the cushion each should be firmly connected. Check each air cell is securely attached to its connecting air pipe. 4. Check all cells, pipes and hoses for any air leakage. 5. Check that the air filter cover is correctly secured and the air filter is clean. 6. Switch on power. 1. Check all air hoses along the inside of the cushion each should be firmly connected. Check each air cell is securely attached to its connecting air pipe. Warning LED A Pressure too high 1. Reset the warning turn off power and press the audible warning button. 2. Disconnect the air hoses to reduce pressure, reconnect when pressure has decreased. 3. Check for twists in the air hoses between Cushion and Control Unit. 4. Switch on power. Warning LED A+B Alternating Mode Failure (no alternation) 1. Reset the warning turn off Power and press the audible warning mute button. 2. Disconnect the air hoses to reduce pressure reconnect when pressure has decreased. Warning LED A,B+C Initialising Failure 1. Press the audible warning mute button to silence the audible warning. 2. Check the power cable is firmly plugged into the mains outlet and the Control Unit; and check the mains power is switched on. 3. Check the Control Unit fuse (1 AMP) fuses can be released using a screwdriver to push and turn. 5
6 4. Installation 4.1 Cushion (This is the applied part type BF) Place the Dyna-Pad Mercury Advance Alternating Cushion directly on to the chair ensuring that the Blue multi-stretch waterproof cover is on top and that the umbilical hose is located at the left hand front corner of the chair. Note: Do not place any other cover on top of the cushion as this will reduce the cushion s pressure reducing characteristics. Static Cushion Use The Dyna-Pad Mercury Advance Alternating Cushion can be used as a pressure reducing cushion for patients at risk of pressure ulcer damage without the need to attach the pump. Alternating Cushion Use If / When required, the Dyna-Pad Mercury Advance Alternating Cushion can be used as an alternating cushion by attaching the Dyna-Pad Mercury Advance Alternating Cushion pump system. No other system should be attached to the cushion as the design settings and internal air pressure properties of the Dyna-Pad Mercury Advance Alternating Cushion pump are specific to this cushion only. The startup time from static to dynamic mode is immediate. 4.2 Power Unit (Pump) Hang the Power Unit (Pump) on the chair or place safely on the floor. The mounting hooks swivel to suit the thickness of the footboard or rail. Connecting the Umbilical Hose to the Power Unit (Pump), place the 3-pin electrical plug into the wall outlet and switch on: (a) Open the zip located at the bottom left hand side of the cushion and pull out the Blue Umbilical hose. (b) Attach the Blue Umbilical Hose to the Power Unit (Pump) by connecting the air connector at the end of the Umbilical Hose to the air inlet connector at the bottom left hand side of the pump. Ensure that the Red CPR Release button is located on top of the Air Inlet connector after connection is complete. (c) Re-close the zip as far as possible without clamping the Blue Umbilical Hose to ensure the cushion and air cells are sealed within the cover. (d) Shut down is the reverse of items a, b & c above. 5. Operation Attach the mains cable to the pump by inserting the kettle type connector into the recess located on the left hand side of the pump. The mains cable has been designed specifically as a removable part to aid in easy replacement should it become damaged in use. The mains plug should be turned off and removed from wall socket as a means of isolation. Plug the mains cable into a suitable 230v mains socket and switch on the Power Unit using the on/off switch. After the pump has been turned on both the High and the Low lights will flash together intermittently until the pump has attained its initial operating pressure. Once the pump has attained its initial operating pressure the Low light will stay on constantly and the cushion is ready for use. 6
7 USER MANUAL 5.1 Low / High Settings The Dyna-Pad Mercury Advance Alternating Cushion, in Alternating Mode, has two pressure settings. The initial setting that the pump will revert to upon set up is Low. The Low comfort setting is ideal for the lighter patient or those who feel discomfort when on a normal alternating air type cushion system. However, for patients with existing pressure damage or those at Very High Risk, it is recommended that dependant on the clinical judgement of the clinician, the High setting is activated by pressing the +/- button once, which is located on top of the pump. In High Mode the pump attains more of the characteristics of an alternating air cushion system whilst still utilising the advantages of the static foam inserts. Repeatedly pressing the mode button enables the Low & High modes to be selected in turn. 5.2 CPR Deflation The CPR system consists of a manually operated button located on the Air Inlet connector attached to the pump. By pressing the Red Button, which will release the connector locking system, the user can remove the connector unit which will deflate the cushion air system back to that of a static foam cushion. Note: After a short period as the cushion deflates the Low Pressure Audible Warning is activated and can be cancelled by switching the Power Unit off. 5.3 Troubleshooting For assistance (if needed) in setting up, using or maintaining the Dyna-Pad Mercury Advance Alternating Cushion System, or to report unexpected operation or events, please contact Direct Healthcare Services on the contact details on the reverse of this manual. 6. Transportation To change the location of the cushion, remove the Umbilical Cord and allow the cushion to return to its Static Cushion form. Switch off the Power Unit (Pump) using the on/off switch and disconnect the electrical supply cable from the mains socket. The cushion can now be moved to a new location where it must immediately be reconnected to the mains electrical supply and the Power Unit (Pump) switched back on. Once the Cushion has been refilled, the Alternating mode will automatically revert back to the Low setting and should be reselected to High should this be desired by the clinician. Warning: The Cushion will not alternate when disconnected from the Power Unit (Pump) and /or the mains electrical. Also refer to environmental conditions section at rear of this manual. 7. Warnings Warning conditions are indicated by a flashing red display accompanied by an audible warning. In each case the user should respond by turning the Power Unit s switch off and investigating the cause. 7.1 High Pressure Warning This condition could be caused, for example by a kinked Umbilical Hose or visitors, and others, sitting suddenly on the Cushion. 7.2 Low Pressure Warning This condition could be caused, for example, by incorrect fitting of the air inlet connector, opening of the CPR Valve or a leak in the Cushion due to a cut or puncture. 7.3 Mains Failure Warning This condition may be caused, for example if Mains power is lost. 7
8 7.4 Alternating Mode Failure (no alternation) This will be indicated by a warning LED on A and B and an audible warning. 1. Reset the warning turn off Power and press the audible warning mute button. 2. Disconnect the air hoses to reduce pressure reconnect when pressure has decreased. 7.5 Initialising Failure This will be indicated by a warning LED on A, B and C and an audible warning. 1. Press the audible warning mute button to silence the audible warning. 2. Check the power cable is firmly plugged into the mains outlet and the Control Unit; and check the mains power is switched on. 3. Check the Control Unit fuse (1 AMP) fuses can be released using a screwdriver to push and turn. 8. Maintenance Procedures 8.1 Safety Warning Only qualified technicians trained or formally approved by Direct Healthcare Services Ltd. in the operation and maintenance of Direct Healthcare Services products may carry out maintenance, modification or repair work on the equipment. Unqualified personnel attempting to work on Direct Healthcare Services Power Units risk serious injury to themselves and others and possibly death by electrocution. Inlet fuse NOT to be replaced by operator or patient, to be replaced by service personnel only. Warning Do not modify this equipment without authorisation of Direct Healthcare Services Servicing A service light will illuminate when a service is due. Direct Healthcare Services (DHS) recommend that the Power Unit (Pump) should be serviced every 8760 hours of operation (one continuous year running). The unit contains no user serviceable parts and should only be carried out by persons as described in section 8.1. DHS will make available on request service manuals, component parts lists and other information necessary for any suitably qualified person (As in 8.1) to carry out repair or service the system. For Service, maintenance and any questions regarding this please contact DHS. 8.2 Cleaning Procedures Warning: Before cleaning the System make sure that the Power Unit (Pump) is disconnected from the mains electricity supply. Do not immerse the Power Unit (Pump) in water or other fluids. Do not autoclave, nor use phenol for cleaning. Do wash hands before commencing the cleaning process. Wear appropriate protective clothing such as gloves, apron and a mask. Ensure all work surfaces are cleaned before and after contact with the Cushion Warning Cleaning the Cushion 1. Cleaning should take place after use or between patients. 2. With cover left on the cushion disconnect the cushion from the Power Unit (Pump). 3. Clean the surface of the wash down table with Hypochlorite solution or equivalent disinfectant. 4. Wash cushion top using hot water (60 degrees C) containing detergent dry with a paper towel. 5. For heavy contamination use a Hypochlorite solution 1,000 parts per million available chlorine. 6. Using suitable brush, hot water, detergent or Hypochlorite solution, clean Umbilical Hose and CPR Valve. Dry with paper towel. 7. If required, the cushion Cover may be removed and machinewashed at a temperature of 80 degrees C, for not less than 10 minutes. The individual Air Cells can be wiped down with established disinfectants. 8. To avoid shrinkage of the cover line dry in an indoor clean environment or tumble dry on a low heat setting not exceeding 40 degrees C and not for longer than 10 minutes. Covers must be thoroughly dried before re-fitting to the cushion. 8.4 Warning Cleaning the Power Unit (Pump) The Power Unit can be cleaned by wiping with a cloth dampened with a detergent solution or Hypochlorite solution. Also refer to symbol chart Warning Ensure the Dyna-Pad Mercury Advance Alternating Cushion System is not exposed to: 1. Excessive heat sources e.g. fires, radiators etc. 2. Water, particularly immersion of the pump. 8
9 USER MANUAL 9. Technical Data 9.1 Power Unit (Pump) Serial Number...As per label on rear of pump Electrical Supply volt, 50 Hz Power Consumption...10 watts Fuses...TA1H 250V Protection against shock...class 2 Noise Level...Approx. 30 db (A) Dimensions x 160 x 95 mm Weight kg Service Interval months / 8760 hours Expected life...5 years Shelf life of parts...5 years 9.2 Cushion Serial Number... Label on inside of cushion cover Number of Air Cells...5 Air Cells / 1 Static Foam Cell Dimensions x 460 x 100mm (Nominal) Weight...3 kg Expected life of cushion...5 years Shelf life of cushion parts...5 years 10. Optimum Conditions (Applies to Cushion and Pump) 10.1 Environment Conditions for Use Transport C +70 C Storage C +70 C Usage C +40 C Humidity... 10% 93% Atmospheric Pressure hPa 1060hPa Operational Altitude m 10.2 Exposure Exposure to direct sunlight, dust, lint and general debris is not considered to be an issue with the Dyna-Pad Mercury Advance Alternating Cushion System. 11. Symbols Guide Cushion Symbols WASH AT 80 REFER TO USER MANUAL DO NOT BLEACH MAXIMUM USER WEIGHT LIMIT 254 KG / 40 STONES WARNING THIS IS A STATEMENT THAT ALERTS THE USER TO THE POSSIBILITY OF SERIOUS INJURY OR OTHERWISE ADVERSE REACTIONS WITH THE USE OR MISUSE OF THE DEVICE General Symbols CAUTION HUMIDITY LIMITATION Pump (Unit) Symbols SERVICE REQUIRED TUMBLE DRY ON LOW 0843 DO NOT IRON DO NOT USE SHARP INSTRUMENTS PROTECT FROM HEAT AND RADIOACTIVE SOURCES ATMOSPHERIC PRESSURE LIMITATION REFER TO USER MANUAL DO NOT DRY CLEAN TYPE BF APPLIED PART CAUTION NO SMOKING DO NOT USE PHENOL THIS IS A STATEMENT THAT ALERTS THE USER TO THE POSSIBILITY OF A PROBLEM WITH THE SYSTEM ASSOCIATED WITH ITS USE OR MISUSE TEMPERATURE LIMITATION DO NOT DISPOSE OF WITH HOUSEHOLD WASTE. PLEASE REFER TO DHS WEBSITE DOUBLE INSULATED CLASS II 0843 IP: INGRESS PROTECTION 2: PROTECTION AGAINST FINGERS OR OTHER OBJECT NOT GREATER THAN 80MM IN LENGTH AND 12MM IN DIAMETER 1: PROTECTION FROM VERTICALLY DRIPPING WATER 9
10 Contraindications For Use (Warning) The Dyna-Pad Mercury Advance Alternating Cushion System should not be used for patients with unstable fractures, gross oedema, burns, or intolerance to motion. General Information (Caution) (Warning) There are no special skills required to operate the system. The Medical Professional is responsible for applying his/her best medical judgment when using the system. The electricity supply is of the type indicated on the Power Unit (pump). Check the mains lead is free from damage and is positioned so as not to cause an obstruction, or injury. E.g. Strangulation of a child or trip hazard. Ensure the mains lead cannot become trapped or crushed, e.g. within the mechanism of the chair, footstool or another object. The power unit (pump) must only be used with a suitably approved power cord and plug set as supplied by DHS. The system is not to be used in the presence of flammable anaesthetics. Suitable for continuous use. Not suitable for sterilisation. Do not position the power unit to make it difficult to disconnect the power supply or plug. Do not place the System on or close to a source of heat. Do not use with hot water bottles or electric blankets. DHS strongly advise against smoking whilst the Power Unit (pump) is in use. This is to prevent accidental secondary ignition of items which may be flammable e.g. bed linen. The materials used in the manufacture of the Dyna-Pad Mercury Advance Alternating Cushion System comply with the required fire safety regulations. Do not use sharp objects on or near the cushion system as this will cause damage. Do not store in damp conditions. Do not use in an oxygen enriched environment. Not suitable for use in an Outdoor Environment. Intended for both Home Healthcare and Professional Healthcare environments. Do not connect to any other medical device or equipment. Correct fuse rating MUST be used. Failure to do so could result in the risk of a fire. The System should be cleaned after use or between patients. Refer to Cleaning section. All internal and external hoses must be free of twists, kinks. The external hose should also be properly connected and positioned so that the risk of obstruction or injury is eliminated. Do not use bleach, phenols. Chlorine based products which exceed 1000ppm. Solvents or alcohol based cleaners. All the above warnings and cautions together with safety considerations should be observed at ALL times during its use. Select correct setting Hi or Low as required. Care should be taken not to accidentally change settings once set. This may affect the desired requirement of the therapy. This could also be caused by pets, pests or children. This device does not emit radiation. 12. Detachable/Removable Parts 1. Cushion (Detached from the pump by removing the CPR connector). Part No. CUSH/ADV/ALT/46/46/10 (or variants of for the size) 2. Electric power cable. (Removed from the pump by pulling the cable away from the mains inlet on the side of the pump). Part No. DHS/ADV/MLEAD N.B. The battery is an integral part of the PCB and is not removable or changeable. Caution Use of detachable parts not listed is not recommended by Direct Healthcare Services. 13. Disposal Please refer to DHS website for recommendations and responsibilities for disposal within the UK WEEE guidelines. 10
11 EMI/EMC Statement and Manufacturer s Declaration This equipment has been tested and found to comply with the limits of EN These limits are designed to provide reasonable protection against harmful interference in both a medical and residential environment. This equipment generates, uses and can radiate radio frequency energy and, if not used in accordance with manufacturer s instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception or other equipment, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment. Connect the equipment to an outlet on a circuit different from that to which the receiver or equipment was connected. The equipment having been tested to operate within the limits of electromagnetic compatibility. (Immunity to interference from nearby sources radiating radio frequency energy). Sources exceeding these limits may give rise to operation faults. Where possible the system will sense the interference and if it is of short duration transparently take countermeasures whilst operating near normally, or failing this will issue a warning and take measures for the continued safely of the user. Further increased levels of energy may cause the system to stop operating, continuously generate random faults or continuous resets. Try to ascertain the source of the interference by turning nearby or suspect equipment off, and see if the interference effects stop. In any such event the user is encouraged to try to correct the interference by one of the following measures: Have the interfering equipment repaired or replaced. Reorient or relocate the interfering equipment. Increase the separation between the equipment and the possible source of the interference. Connect the equipment to an outlet on a circuit different from that to which the interfering equipment was connected. Information regarding Electro Magnetic Compatibility (EMC) according to IEC :2007, clause 6.8 With the increased number of electronic devices such as PC s and mobile telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. The EMC (Electro Magnetic Compatibility) standard IEC defines the levels of immunity to these electromagnetic interferences. From the other hand, medical devices must not interfere with other devices. IEC also defines the maximum levels of emissions for these medical devices. Sales Offices UK & Europe Direct Healthcare Services Ltd Withey Court Western Industrial Estate Lon-y-Llyn, Caerphilly, CF83 1BF, UK T: +44 (0) info@directhealthcareservices.co.uk Asia Pacific Direct Healthcare Services PTY Ltd. PO Box 562 Wembley Western Australia 6913 T: +61 (0) info@directhealthcareservices.com.au ISO 9001:2008 EN ISO 13485:2012 Issue 2 Date: January 2016
Service Manual DIRECTHEALTHCARESERVICES.CO.UK
Service Manual DYNA-FORM MERCURY ADVANCE BARI SERVICE MANUAL The Dyna-Form Mercury Advance Bari mattress is a Very High Risk dynamic replacement system, combined with the benefits of modern foam technology.
More informationService Manual DIRECTHEALTHCARESERVICES.CO.UK
Service Manual DYNA-FORM MERCURY ADVANCE SERVICE MANUAL The Dyna-Form Mercury Advance is a pressure relieving mattress suitable for use with patients at VERY HIGH RISK of pressure ulcer damage. Offering
More informationOPERATION MANUAL HARVEST ROYAL
ALL PUMPS SUPPLIED BY HARVEST HEALTHCARE COMPLY TO THE FOLLOWING STANDARDS LISTED BELOW BS 5724 PART 1 IEC 601-1 HARVEST HEALTHCARE BRADMARSH BUSSINESS PARK BRADMARSH WAY ROTHERHAM SOUTH YORKSHIRE ENGLAND
More informationOPERATION MANUAL HARVEST CAVALIER
ALL PUMPS SUPPLIED BY HARVEST HEALTHCARE COMPLY TO THE FOLLOWING STANDARDS LISTED BELOW BS 5724 PART 1 IEC 601-1 HARVEST HEALTHCARE BRADMARSH BUSSINESS PARK BRADMARSH WAY ROTHERHAM SOUTH YORKSHIRE ENGLAND
More informationEFFECT 500 Mattress Overlay System
EFFECT 500 Mattress Overlay System User Manual CONTENTS CHAPTER 1 PAGE Contents 1 Important Safeguards 2 Note, Caution and Warning Statements 2 Symbols 2 Support Settings & Procedures 3 Effect 500 Weight
More informationACTIVE SEAT SYSTEM. General User/ Safety Guide. ACTIVE CUSHIONS
General User/ Safety Guide ACTIVE SEAT SYSTEM ACTIVE CUSHIONS www.harvesthealthcare.co.uk E sales@harvesthealthcare.co.uk www.harvesthealthcare.co.uk 1 CONTENTS WARNINGS & CAUTIONS GENERAL INFORMATION
More informationATTIVO Dynamic Seating System User Guidelines
...reducing avoidable harms ATTIVO Dynamic Seating System User Guidelines Explanation of Label Symbols and Statements Caution Temperature limitation Refer to instructions of use / booklet Medical Devices
More information1200W INVERTER GENERATOR
1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use
More informationRESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK PARTS DESCRIPTION
RESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK CONTENTS 1. Introduction 2. Parts Description 3. Personal Safety 4. Installation Instructions 5. Backrest Removal 6. Operating Instructions and Guidelines
More informationUplift Premium Power Lifting Seat
Uplift Premium Power Lifting Seat User Guide Read all instructions before using the Uplift Power Seat DANGER - To reduce the risk of electric shock: IMPORTANT SAFETY INSTRUCTIONS Always unplug the Uplift
More informationRESTWELL RISE & RECLINE ARMCHAIRS INTALIFT - OWNER S HANDBOOK PARTS DESCRIPTION
RESTWELL RISE & RECLINE ARMCHAIRS INTALIFT - OWNER S HANDBOOK CONTENTS 1. Introduction 2. Model Description 3. Parts Description 4. Personal Safety 5. Installation Instructions 6. Backrest Removal 7. Operating
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
7.5 Swift Lock Ready Shape Tree (Patent Pending) Instructions IMPORTANT SAFETY INSTRUCTIONS When using electrical products, basic precautions should always be followed including the following: READ AND
More informationJAY. J2, X2, & Xtreme Cushion Products JAY J2, X2 & XTREME
JAY J2, X2 & XTREME JAY J2, X2, & Xtreme Cushion Products IMPORTANT CONSUMER INFORMATION NOTICE: This manual contains instructions for use with the foam cushion products. This information must be passed
More informationHybrid Pressure Relief
Pressure Relief System 2. 5 Year Extended Warranty * 3. Use with Very High Risk Patients 4. Dual Cell Technology 5. Maximum Patient Weight of 250Kg 6. Unlimited Technical Support ** The Gio-Form system
More informationBEDSIDE AIR CHAIR Pressure Relieving System Operating Instructions Tridien Medical Revision: AO-SM600AC-04
BEDSIDE AIR CHAIR Pressure Relieving System Operating Instructions Tridien Medical Revision: AO-SM600AC-04 ! WARNING Before operating this medical equipment, it is important to read this manual and to
More informationPodiatry Procedures Chair. For Models: Barrier-Free. User s Guide
Podiatry Procedures Chair For Models: 646 647 Barrier-Free User s Guide Product Information (The information below is required when calling for service.) Dealer : Date of Purchase: Model / Serial Number:
More informationUser s Manual. Automatic Switch-Mode Battery Charger
User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service
More informationCordless Rechargeable Saw Instructions for Use
Technical data Voltage: DC 10.8V Weight: 1.25Kg Stroke rate: 0-2100/min Stroke: 15mm Cutting capacity: max diameter in wood 80mm / in soft metal 7mm Charging time: Between 5.0-5.5 Hours Battery: 1.3Ah
More informations h a p e f i t t i n g t e c h n o l o g y
Operation Manual Supplier: This manual must be given to the user of this product. Operator (Individual or Caregiver): Before using this product, read instructions and save for future reference. s h a p
More informationOperator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:
Storage System Ultrasound Probe Cabinet Operator's Manual Manufactured by: CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA 319.248.6757 / 800.445.6741 WWW.CIVCO.COM Copyright 2018 All
More informationREDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S MANUAL.
operator's MaNUal Cat. No. C12-28 DCR Job Site Radio TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S MANUAL. Read these instructions. Keeps these instructions. Heed all warnings.
More informationREAD AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
5 Swift Lock Ready Shape Tree (Patent Pending) Instructions IMPORTANT SAFETY INSTRUCTIONS When using electrical products, basic precautions should always be followed including the following: READ AND FOLLOW
More informationLanguage specific user manuals are available on
User Manual WEB Charger for LiFePO 4 Batteries EN User Manual Language specific user manuals are available on www.mascot.no/downloads/usermanuals Bruksanvisning Käyttöohjeet Bedienungsanleitung Mode d
More informationOPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH
OPERATING MANUAL POWER DRIVE SYSTEM Cat. No. 400005 525-1300-00 RevH System components Symbol Definitions Qty Description Catalog Number 1 Power Drive System 300106 1 Controller 300108 1 Cutter Drive
More informationAuto Logic. Instructions for Use. ...with people in mind EN_06 11/2017
Auto Logic Instructions for Use 630933EN_06 11/2017...with people in mind WARNING To avoid injury, always read this Instructions for Use and accompanied documents before using the product. Mandatory to
More informationCAUTION-ELECTRICALLY OPERATED PRODUCT:
CAUTION-ELECTRICALLY OPERATED PRODUCT: NOT RECOMMENDED FOR CHILDREN UNDER 8 YEARS OF AGE, AS WITH ALL ELECTRIC PRODUCTS, PRECAUTIONS SHOULD BE OBSERVED DURING HANDLING AND USE TO PREVENT ELECTRIC SHOCK,INPUT:120V
More informationWARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS
WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: 8877100 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0217 INTRODUCTION Thank you for purchasing
More informationGet Cleaning... User Guide Vax Careline: (UK) (ROI) Cordless Handheld. H90-LF Series. vax.co.uk
H90-LF Series LiFE Handvac User Guide v4.qxd:user guide 10/3/10 09:55 Page 1 Cordless Handheld User Guide Vax Careline: (UK) Get Cleaning... What s your Vax s model number? H 9 0 L F What s your serial
More informationCharging base guide. A Sonova brand
Charging base guide A Sonova brand Thank you Thank you for choosing this rechargeable solution. We care deeply about people with hearing loss. We work closely with hearing healthcare professionals to make
More informationMULTI FUNCTION POWER PAK PLUS
MULTI FUNCTION JUMP START UP TO V8 PETROL & DIESEL 600A PEAK CURRENT RECHARGE USB POWER TOOLS TABLETS LAPTOPS MOBILE PHONES RECHARGE DEVICES ON-SITE VEHICLE JUMP STARTER KP1404 ED2 (June 15) Table of Contents
More informationBack-Up Sensor System
Back-Up Sensor System Model No.: PKC0RE Owner s Manual and Warranty Information OFF ON 0.4m/1.3ft 0.6m/2.0ft 1.0m/3.3ft 1.2m/4.0ft 1.5m/5.0ft LEFT RIGHT Read these instructions completely before using
More informationUplift Power Seat Users Guide
Safety Precautions 1. Use the Uplift Power Seat only in armchairs or sofas with at least one armrest for optimum stability when sitting or rising. 2. Uplift Power Seat is not intended for use in rocking
More information1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY
1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY CONTENTS Warranty 2 Introduction 3 Environmental protection 3 Specifications 3 General safety warnings and instructions 4 Important safety instructions
More informationModel: SPTOGT01 TRACTOR PTO GENERATOR
www.scintex.com.au sales@scintex.com.au Model: SPTOGT01 TRACTOR PTO GENERATOR SET UP, OPERATING, AND SERVICING INSTRUCTIONS Read this material before using this product. Failure to do so can result in
More informationINDEX. Specifications 1. Important Safety Precautions & Set up. 2. Operating Instructions 3. Castors & Battery Backup 4. Air Comfort Seating System 5
INDEX Specifications 1 Important Safety Precautions & Set up. 2 Operating Instructions 3 Castors & Battery Backup 4 Air Comfort Seating System 5 Service & Maintenance 6 Warranty / Service Contract 7 SPECIFICATIONS
More informationLITHIUM ION BATTERY CHARGER
LITHIUM ION BATTERY CHARGER OWNER S MANUAL TOLL-FREE HELPLINE: 1-877-572-7278 (Monday - Friday / 8am - 4:30pm CST) READ ALL SAFETY RULES AND INSTRUCTIONS CAREFULLY BEFORE OPERATING STRIKEMASTER LITHIUM
More informationQuickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority
Quickdraw Model 2400 Series Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com
More information1100W PORTABLE GENERATOR
1100W PORTABLE GENERATOR MODEL NO: G1200 PART NO: 8010110 OPERATION & MAINTENANCE INSTRUCTIONS LS0312 INTRODUCTION Thank you for purchasing this CLARKE 1100W Portable Generator. Before attempting to use
More information60V RECHARGEABLE LITHIUM-ION BATTERY
60V RECHARGEABLE LITHIUM-ION BATTERY LB60A00/LB60A03/LB60A01/LB60A02 Owner s Manual TOLL-FREE HELPLINE: 1-855-345-3934 www.greenworkstools.com Read all safety rules and instructions carefully before operating
More informationAirTMCordless HANDHELD
AirTMCordless HANDHELD PERFECT FOR QUICK SPILLS AND SPOT CLEANING LET S GET STARTED. H85-ACH-B H85-ACH-BD H85-ACH-BA Let s talk safety Basic safety precautions This handheld cleaner is intended for household
More informationORIGINAL INSTRUCTIONS
OPERATION & MAINTENANCE INSTRUCTIONS CBB200 Shown here BUFFER/POLISHER MODEL NO: CBB150, CBB200 PART NO: 6500485, 6500490 ORIGINAL INSTRUCTIONS LS0818 - ISS 1 INTRODUCTION Thank you for purchasing this
More informationMULTI-FUNCTION JUMP STARTER
MULTI-FUNCTION JUMP STARTER FEATURES 1. Flashlight 2. Jump Start Port 3. LED Power indicator 4. USB Output 5. Power button 6. Charging port 7. Car battery clamp 8. Home charger&car charger 9. Portable
More informationOperating Instructions. International English. CCS Dust Extractor
Operating Instructions International English CCS Dust Extractor Electric Cast Saw Dust Removal System Warnings & Safety Rules WARNING!: THIS EQUIPMENT MUST BE EARTHED! Danger!: Possible explosion hazard
More information7.5 FT PRE-LIT ENGLEWOOD PINE TREE
ITEM #0243778 7.5 FT PRE-LIT ENGLEWOOD PINE TREE Holiday Living & Design is a registered trademark of LF, LLC. All Rights Reserved. MODEL #W14L030 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase
More informationINSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.
INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power
More informationSAFETY RULES SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE OPERATING SAVE THESE INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE OPERATING SAVE THESE INSTRUCTIONS Thank you for purchasing 7" Polisher. Before attempting to operate your new Polisher please read these instructions thoroughly. You will need
More informationGator Pet 18V Let s get started
Gator Pet 18V Let s get started VX35 vax.com.au vax.co.nz Let s talk safety Basic safety precautions This handheld is intended for household use only and NOT for commercial or industrial use. This handheld
More informationLED Twister II. User manual UK Version 1.0
LED Twister II User manual 152.624UK Version 1.0 LED DUOPLEX: For indoor use only CAUTION! Please read this manual carefully before operating! Pay special attention to Sections 3 & 5 of this document.
More informationSeekTech Inductive Clamp
Inductive Clamp Manual SeekTech Inductive Clamp! Read this Operator s Manual carefully before using this tool. Failure to understand and follow the contents of this manual may result in electrical shock,
More informationV3700UK OWNER S GUIDE.
V3700UK OWNER S GUIDE IMPORTANT SAFETY INSTRUCTIONS For Household Use Only WHEN USING YOUR SHARK CORDLESS SWEEPER, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ ALL
More informationuser instructions and warranty airflo (battery version) freedom through lightweight solutions
user instructions and warranty airflo (battery version) freedom through lightweight solutions The irflo by Mangar International, is a low pressure air compressor, which has been designed for use with Mangar
More informationGENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114
GENERATOR MODEL NO: FG2500 PART NO: 8857727 OPERATION & MAINTENANCE INSTRUCTIONS LS0114 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this
More informationXenon Fiberoptic Lightsource
Xenon Fiberoptic Lightsource Operating Instructions for ASB-XE-175W Lightsource 2659A Pan American Frw N.E Albuquerque, New Mexico 87107 USA (English) Page 1 of 12 TABLE OF CONTENTS PAGE 1. INTRODUCTION
More informationRESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK PARTS DESCRIPTION
RESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK CONTENTS 1. Introduction 2. Model Description 3. Parts Description 4. Personal Safety 5. Installation Instructions 6. Backrest Removal 7. Operating Instructions
More informationCar Battery Charger Instructions for Use
BATTERY CHARGER 12Volt 4Amp FOR INDOOR USE ONLY Power Details: Input: 230-240Vac; 50Hz; 52W Output: 12V DC; 2.8A Maximum Charge Rate: 4A RMS Read these instructions before operating this car battery charger
More informationSurePower Battery Pack Guide
? SurePower Battery Pack Guide 9650-0536-01 Rev. B The issue date for the SurePower Battery Pack Guide (9650-0536-01 Rev. B) is September, 2010. If more than three years have elapsed since the issue date,
More information1000-Watt Energy Center
1000-Watt Energy Center OPERATING INSTRUCTIONS Patent Pending Sierra Wave 1000-Watt Energy Center #9675 The Sierra Wave 1000-Watt Energy Center is a heavy duty and efficient portable power center offering
More informationWELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04
WELDING INVERTER PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL PEGAS 160-200 E Smart Manual EN 04 2/12 CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL DATA...
More informationBluetooth Smart Speed/Cadence Sensor Instruction Manual
Bluetooth Smart Speed/Cadence Sensor Instruction Manual Contents Before using this product... 3 Warranty... 4 List of Parts... 4 Battery... 6 Installation... 7 Pairing... 11 Technical Specs... 11 2 WARNINGS:
More informationUser Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on
User Manual Charger for LTO Batteries EN User Manual Language specific user manuals are available on www.mascot.no/downloads/usermanuals Bruksanvisning Käyttöohjeet Bedienungsanleitung Mode d emploi Manual
More informationDCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority
DCell Suction Model DM10-001 Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com
More information58kHz AM Deactivator DB104 Instruction Manual V1.0
58kHz AM Deactivator DB104 Instruction Manual V1.0 Copyright 2016, Hangzhou Century Co., Ltd. All rights reserved. Table of Contents 1 System Overview...3 2 Precautions... 4 2.1 Input Voltage...4 2.2 Safety
More information82V LITHIUM-ION BATTERY CHARGER GC 400
82V LITHIUM-ION BATTERY CHARGER GC 400 (2907302) Owner s Manual TOLL-FREE HELPLINE: 1-855-470-4267 www.greenworkstools.com/82v-commercial/ Read all safety rules and instructions carefully before operating
More informationOPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.
Requires Manual Shut Off. 6 / 2 AMP,, DUAL RATE BATTER TTERY CHARGER 45005 OPERATING INSTRUCTIONS E224783 E224783 Note: 6V Charging Due to continuing improvements, actual product may differ slightly from
More information12VDC TO 230VAC INVERTERS
12VDC TO 230VAC INVERTERS 12VDC TO 230VAC INVERTERS MODEL Nos: CI-200 CI-400 CI-600 CI-800 CI-1000 CI-1500 OPERATION & MAINTENANCE INSTRUCTIONS 0706 Thank you for purchasing this CLARKE Power Inverter.
More information3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV
3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV PART NO: 8857815 OPERATION & MAINTENANCE INSTRUCTIONS LS1016 INTRODUCTION Thank you for purchasing this CLARKE 3KVA Dual Voltage Generator. Before attempting
More information1200W CaR PoliSheR en RS4900
1200W Car Polisher RS4900 RS4900 8 1 2 7 3 4 5 6 A B flat nozzle C D E F 1200W Car Polisher RS4900 G H flat nozzle I J K L 4 1200W Car Polisher COMPONT LIST 1 2 3 4 5 6 7 Variable speed control Switch
More informationELECTRIC CAR POLISHER
ELECTRIC CAR POLISHER MODEL NO: CP254 PART NO: 6462108 OPERATION & MAINTENANCE INSTRUCTIONS LS0610 INTRODUCTION Thank you for purchasing this CLARKE electric car polisher. Before attempting to use this
More informationSOOTHING SOUNDS BOUNCER SEAT
SOOTHING SOUNDS BOUNCER SEAT Model Number: 79598 Please save these instructions for future reference. Adult assembly is required. Tools required for assembly: Phillips Screwdriver and adjustable wrench
More informationROHO Enhancer Cushion (1 of 5)
i If you need your information in another language or medium (audio, large print, etc) please contact Customer Care on 0800 374 208 or send an email to: customercare@ salisbury.nhs.uk You are entitled
More informationDIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE
DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE W.CHRISTIE (INDUSTRIAL) LTD CHRISTIE HOUSE, MEADOWBANK ROAD, ROTHERHAM, SOUTH YORKSHIRE, S61 2NF, UK T: +44(0)1709 550088 F: +44(0)1709 550030 E:
More informationINSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.
INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power
More informationUSER MANUAL MPS 1-5KW SERIES
USER MANUAL MPS 1-5KW SERIES Low Series Frequency Solar and Wind Power Charging Inverter CONTENTS 1 WWW.NEXTGENNRG.COM 1. Introduction... 3 2. Profile Structure 4 2.1. Working Principle 4 2.2.Product Features..5
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS BATTERY CHARGER IR-200BC TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 3 3. HANDLING PRECAUTIONS... 3 4. NOMENCLATURE AND FUNCTIONS... 4 5. CHARGING... 5
More informationUV-AIRE AIR PURIFYING SYSTEM
UV-AIRE AIR PURIFYING SYSTEM Model: UV-16/24 The UV-Aire unit is designed to emit powerful UVC Band light rays, which sterilize and reduce airborne microorganisms as they pass through a heating or air
More informationIMPORTANT SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS 1
IMPORTANT SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS 2 MAIN COMPONENTS ITEMS INCLUDED SPRAYER TANK 6.8 VOLT BATTERY -3400 mah 6.8 VOLT CHARGER NOZZLE WRENCH TANK CAP
More informationDeltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord
Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System Designed for Six-cell and three-cell Flooded/AGM/GEL Lead-Acid Batteries and Four-Cell Lithium Iron Phosphate (LiFePO4) Batteries
More informationPOWER PAK II / PLUS II
POWER PAK II / PLUS II MULTI FUNCTION JUMP STARTERS KP1405 & KP1406 ED2 (December 17) Table of Contents Know Your Product... 2 POWER PAK II Safety Instructions... 3-4 POWER PAK II Care & Charging... 5-6
More informationAirless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure
INSTRUCTIONS DP-6376 Airless Spray Gun 5000 psi (345 bar) Maximum Working Pressure INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Table of Contents Warnings......................................
More information4 AMP WATERPROOF BATTERY CHARGER/MAINTAINER INSTRUCTION MANUAL
4 AMP WATERPROOF BATTERY CHARGER/MAINTAINER INSTRUCTION MANUAL CBC4W SAVE THIS MANUAL FOR FUTURE REFERENCE. CONSERVE ESTE MANUAL PARA FUTURAS CONSULTAS. CBC4W_ManualENSP_041414.indd 1 BC 4/14/2014 10:20:43
More informationMOBILE AIR CHAIR. Operating Instructions. Pressure Relieving System. Tridien Medical. Revision: AO-SM150-03
MOBILE AIR CHAIR Pressure Relieving System Operating Instructions Tridien Medical Revision: AO-SM150-03 WARNING Before operating this medical equipment, it is important to read this manual and to understand
More informationAeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference.
AeraMax Pro AM IV Please read these instructions before use. Do not discard: keep for future reference. ENGLISH AeraMax PRO Air Quality Control System: AM IV SAFETY INSTRUCTIONS/WARNING Thank you for purchasing
More informationPerfectTilt RF Motorized Shutter User Manual
PerfectTilt RF Motorized Shutter User Manual Pictured: PerfectTilt RF Solar with auxiliary solar panels and auxiliary battery pack INTRODUCTION The PerfectTilt RF motorization system features a remote
More informationHOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5
CONTENTS IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5 OPERATION 8 SPECIFICATIONS 8 MAINTENANCE 9 HOME CHARGER MODE 2 Series 31328 to 31340 16/32A single phase FCC INFORMATION 9 WARRANTY
More informationRPS1215 ORIGINAL INSTRUCTIONS. Cordless Pruner
RPS5 ORIGINAL INSTRUCTIONS Cordless Pruner Important! It is essential that you read the instructions in this manual before assembling, operating and maintaining the product. Subject to technical modification.
More informationBattery Charger JCB-FCH20LI2
Safety and operating manual Battery Charger JCB-FCH20LI2 ORIGINAL INSTRUCTIONS SAFETY INSTRUCTIONS WARNING: Read all safety warnings and all instructions.failure to follow the warnings and instructions
More informationROHO Select Cushions (1 of 6)
i ROHO Select Cushions (1 of 6) Why do I need a ROHO cushion? Due to the nature of your injury your skin may be susceptible to pressure marks and ulcers. A specialist cushion has been prescribed to meet
More information5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616
5.5KVA GENERATOR MODEL NO: PG6500DVES PART NO: 8857810 OPERATION & MAINTENANCE INSTRUCTIONS LS0616 INTRODUCTION Thank you for purchasing this CLARKE 5.5KVA Generator. Before attempting to use this product,
More informationSoothe n Play. Model Number: B0771
Soothe n Play Bouncer Model Number: B0771 Please keep this instruction sheet for future reference, as it contains important information. Adult assembly is required. Tool required for assembly: Phillips
More informationPro~Active 2. User Guide. LFT5170 Issue 4
Pro~Active 2 User Guide LFT5170 Issue 4 PRO-ACTIVE 2 Seating System PRO-ACTIVE 2 Seating System. The versatile dynamic seating system for the prevention and therapy of pressure sores. The PRO-ACTIVE 2
More informationU S E R M A N U A L. Configura Comfort 1. Instructions for Use. Configura Comfort 1. enablelifecare.com.au
U S E R M A N U A L Configura Comfort 1 Instructions for Use enablelifecare.com.au Design Policy & Copyright and are trademarks belonging to Accora Ltd unless otherwise stated. As our policy is one of
More informationSTEP-BY-STEP INSTALLATION GUIDE
Battery Backup System STEP-BY-STEP INSTALLATION GUIDE Operating Instructions & Parts Manual ESP25 Please read and save these instructions. Read carefully before attempting to assemble, install, operate
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More informationMR5501 MR SAFE Adjustable Height Patient Trolley
September 2010 GEN.S.10/167a MR5501 MR SAFE Adjustable Height Patient Trolley OPERATORS MANUAL Specification The MR5501 trolley is designed to be MR compatible, and is manufactured and tested to the highest
More informationModel: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
U V - AIRE AIR PURIFYING S YSTEM Model: UV-16R/24 ITEMS INCLUDED IN KIT: 1-24Volt UV-Aire Ballast Assembly 1-Mounting Base 1-Ultraviolet Lamp 6-Sheet Metal Mounting Screws 1-Instruction Sheet 1-Fiberglass
More informationR18SPL. ORIGINAL INSTRUCTIONS 18V Dual Power LED Spotlight
R18SPL ORIGINAL INSTRUCTIONS 18V Dual Power LED Spotlight Important! This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack
More informationUSER GUIDE & MANUAL. General Care Guide for Seating Surfaces IS-GENERALCUSHION-0315
USER GUIDE & MANUAL General Care Guide for Seating Surfaces IS-GENERALCUSHION-0315 Thank you for choosing COMFORT COMPANY ABOUT US At Comfort Company we are dedicated to creating and manufacturing seating
More informationBodyGuardTM 323. BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump. Patient Guide
BodyGuardTM 323 BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump Patient Guide How to Use This Booklet This booklet gives you information about how to use your BodyGuard 323 infusion pump. It supplements
More informationUser Guide ALL ELECTRIC EXAMINATION COUCH. Paragon Care Group Pty Ltd ABN Dalmore Drive Scoresby VIC 3179 Australia
ALL ELECTRIC EXAMINATION COUCH User Guide Paragon Care Group Pty Ltd ABN 44 136 627 971 11 Dalmore Drive Scoresby VIC 3179 Australia T 1300 369 559 F 03 8833 7890 info@paragoncare.com.au paragoncare.com.au
More informationOPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems
OPERATION AND MAINTENANCE INSTRUCTION MANUAL AEU-707A & AEU-707AV2 Implant / Surgery Systems TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up the